HomeMy WebLinkAboutT-432616ABBREVIATIONS: 1 P 1 POLE (2P, 3P, 4P, ETC.) T-STAT THERMOSTAT IC INTERRUPTING CAPACITY TTC TELEPHONE TERMINAL CABINET A AMPERE IG ISOLATED GROUND TV TELEVISION AC ABOVE COUNTER IMC INTERMEDIATE METAL CONDUIT TVTC TELEVISION TERMINAL CABINET ACLG ABOVE CEILING INCAND INCANDESCENT TYP TYPICAL ADO AUTOMATIC DOOR OPENER IR INFRARED AF AMP FRAME I/W INTERLOCK WITH UC UNDER COUNTER AFF ABOVE FINISHED FLOOR UE UNDERGROUND ELECTRICAL AFG ABOVE FINISHED GRADE J-BOX JUNCTION BOX UG UNDERGROUND AFI ARC FAULT CIRCUIT INTERRUPTER UH UNIT HEATER AHU AIR HANDLING UNIT KV KILOVOLT UNO UNLESS NOTED OTHERWISE AL ALUMINUM KVA KILOVOLT -AMPERE UT UNDERGROUND TELEPHONE ALT ALTERNATE KVAR KILOVOLT -AMPERE REACTIVE UTIL UTILITY AMP AMPERE KW KILOWATT UV ULTRAVIOLET AMPL AMPLIFIER KWH KILOWATT HOUR ANNUN ANNUNCIATOR V VOLT APPROX APPROXIMATELY LOC LOCATE OR LOCATION VA VOLT-AMPERES AQ-STAT AQUASTAT LT LIGHT VDT VIDEO DISPLAY TERMINAL ARCH ARCHITECT, ARCHITECTURAL LTG LIGHTING VERT VERTICAL AS AMP SWITCH LTNG LIGHTNING VFD VARIABLE FREQUENCY DRIVE AT AMP TRIP LV LOW VOLTAGE VOL VOLUME ATS AUTOMATIC TRANSFER SWITCH AUTO AUTOMATIC MAX MAXIMUM W WATT AUX AUXILIARY MAG.S MAGNETIC STARTER W/ WITH AV AUDIO VISUAL M/C MOMENTARY CONTACT WG WIRE GUARD AWG AMERICAN WIRE GAUGE MC MECHANICAL CONTRACTOR WH WATER HEATER MCB MAIN CIRCUIT BREAKER W/O WITHOUT BATT BATTERY MCC MOTOR CONTROL CENTER WP WEATHERPROOF BD BOARD MDC MAIN DISTRIBUTION CENTER BLDG BUILDING MDP MAIN DISTRIBUTION PANEL XFMR TRANSFORMER BMS BUILDING MANAGEMENT SYSTEM MFR MANUFACTURER XFR TRANSFER MFS MAIN FUSED DISCONNECT SW C CONDUIT MH MANHOLE z ANGLE CAB CABINET MIC MICROPHONE @ AT CAT CATALOG MIN MINIMUM ♦ DELTA CATV CABLE TELEVISION MISC MISCELLANEOUS FEET CB CIRCUIT BREAKER MLO MAIN LUGS ONLY INCHES CCTV CLOSED CIRCUIT TELEVISION MMS MANUAL MOTOR STARTER # NUMBER CCT CIRCUIT MOA MULTIOUTLET ASSEMBLY 0 PHASE CLG CEILING MSP MOTOR STARTER PANELBOARD C CENTER LINE COMB COMBINATION MSBD MAIN SWITCHBOARD P PLATE CMPR COMPRESSOR MT MOUNT CONN CONNECTION MT.0 EMPTY CONDUIT CONST CONSTRUCTION MTS MANUAL TRANSFER SWITCH CONT CONTINUATION OR CONTINUOUS MTR MOTOR, MOTORIZED CONTR CONTRACTOR N.C. NORMALLY CLOSED CONV CONVECTOR NEC NATIONAL ELECTRICAL CODE CP CIRCULATING PUMP NEMA NATIONAL ELECTRICAL CRT CATHODE-RAY TUBE MANUFACTURER'S ASSOCIATION CT CURRENT TRANSFORMER NFDS NON -FUSED SAFETY DISCONNECT SWITCH CTR CENTER NIC NOT IN CONTRACT CU COPPER NL NIGHT LIGHT N.O. NORMALLY OPEN DCP DOMESTIC WATER CIRCULATING PUMP NPF NORMAL POWER FACTOR DEPT DEPARTMENT NTS NOT TO SCALE DET DETAIL DIA DIAMETER OH OVERHEAD DISC DISCONNECT OL OVERLOADS DIST DISTRIBUTION DN DOWN PA PUBLIC ADDRESS DPR DAMPER PB PULL BOX OR PUSHBUTTON DS SAFETY DISCONNECT SWITCH PE PNEUMATIC ELECTRIC DT DOUBLE THROW PED PEDESTAL DWG DRAWING PF POWER FACTOR PH PHASE EC ELECTRICAL CONTRACTOR PIV POST INDICATING VALVE ELEC ELECTRIC, ELECTRICAL PNL PANEL ELEV ELEVATOR PP POWER POLE ELU EMERGENCY LIGHTING UNIT PR PAIR EM EMERGENCY PRI PRIMARY EMS ENERGY MANAGEMENT SYSTEM PROJ PROJECTION EMT ELECTRICAL METALLIC TUBING PRV POWER ROOF VENTILATOR EP ELECTRIC PNEUMATIC PT POTENTIAL TRANSFORMER EQUIP EQUIPMENT PVC POLYVINYL CHLORIDE (CONDUIT) EWC ELECTRIC WATER COOLER PWR POWER EXIST EXISTING EXH EXHAUST QUAN QUANTITY EXP EXPLOSION PROOF RCPT RECEPTACLE FA FIRE ALARM REQD REQUIRED FABP FIRE ALARM BOOSTER POWER RM ROOM FACP FIRE ALARM CONTROL PANEL RSC RIGID STEEL CONDUIT FCU FAN COIL UNIT RTU ROOF TOP UNIT FIXT FIXTURE RRFB RECTANGULAR RAPID FLASHING BEACON FLR FLOOR FLUOR FLUORESCENT SC SURFACE CONDUIT FU FUSE SEC SECONDARY FUDS FUSED SAFETY DISCONNECT SWITCH SHT SHEET SIM SIMILAR GA GAUGE S/N SOLID NEUTRAL GAL GALLON SPEC SPECIFICATION GALV GALVANIZED SPKR SPEAKER GC GENERAL CONTRACTOR SP SPARE GEN GENERATOR SR SURFACE RACEWAY G,GFI GROUND FAULT CIRCUIT INTERRUPTER SS STAINLESS STEEL GFP GROUND FAULT PROTECTOR SSW SELECTOR SWITCH GND GROUND S/S STOP/START PUSHBUTTONS GRS GALVANIZED RIGID STEEL (CONDUIT) STA STATION GYP BD GYPSUM BOARD STD STANDARD SURF SURFACE MOUNTED HOA HANDS -OFF -AUTOMATIC SWITCH SW SWITCH HORIZ HORIZONTAL SWBD SWITCHBOARD HP HORSEPOWER SYM SYMMETRICAL HPF HIGH POWER FACTOR SYS SYSTEM HT HEIGHT HTG HEATING TEL TELEPHONE HTR HEATER TEL/DATA TELEPHONE/DATA HV HIGH VOLTAGE TERM TERMINAL HVAC HEATING, VENTILATING AND AIR TL TWIST LOCK CONDITIONING TR TAMPER RESISTANT REVISION i rffll-III ELECTRICAL GENERAL NOTES: GENERAL: 1. COORDINATE ELECTRICAL WORK WITH MECHANICAL, ARCHITECTURAL, STRUCTURAL, CIVIL AND LANDSCAPE WORK SHOWN ON OTHER CONTRACT DOCUMENTS. PROVIDE ADDITIONAL OFFSETS FOR COORDINATED INSTALLATION WHERE REQUIRED. 2. FIELD COORDINATE FINAL MECHANICAL AND EQUIPMENT LOCATIONS ALONG WITH CONNECTION REQUIREMENTS AND CONTROL WIRING PRIOR TO ROUGH -IN. 3. CONTRACTOR IS RESPONSIBLE FOR PROVIDE ALL LINE VOLTAGE CIRCUITING AND CONNECTIONS TO MECHANICAL EQUIPMENT, PACKAGED UNITS, CONTROL PANELS, MOTOR STARTERS, MOTOR CONTROLLERS, VARIABLE FREQUENCY DRIVES AND SIMILAR EQUIPMENT. COORDINATE ADDITIONAL REQUIREMENTS WITH CONTROLS CONTRACTOR. 4. COORDINATE EQUIPMENT CONNECTIONS WITH MANUFACTURERS' CERTIFIED DRAWINGS. 5. COORDINATE ELECTRICAL, COMMUNICATIONS, AND ELECTRONIC SAFETY AND SECURITY WORK PRIOR TO INSTALLATION. EQUIPMENT ACCESS TAKES PRECEDENCE OVER CONDUIT FOR AVAILABLE SPACE. 6. WHERE USED, THE TERM "PROVIDE" SHALL MEAN "FURNISH AND INSTALL". 7. PROVIDE CONDUCTORS OPERATING AT 50 VOLTS OR GREATER IN RACEWAY. PROVIDE METAL RACEWAY WITHIN THE STRUCTURE ABOVE THE FLOOR SLAB. PROVIDE PVC RACEWAY BELOW THE FLOOR SLAB AND UNDERGROUND RACEWAY OUTSIDE THE STRUCTURE. 8. CONDUIT AND WIRE IS NOT PERMITTED TO BE INSTALLED BELOW FLOOR SLAB UNLESS INDICATED ON PLAN BY DASHED CONDUIT. 9. LEAVE THE SITE CLEAN AND READY FOR OCCUPANCY. REMOVE DIRT, DEBRIS, EMPTY CARTONS, TOOLS, CONDUIT AND WIRE SCRAPS AND MISCELLANEOUS SPARE EQUIPMENT AND MATERIALS USED IN THIS DIVISION OF THE WORK DURING CONSTRUCTION. COMPONENTS SHALL BE FREE OF DUST, GRIT AND FOREIGN MATERIALS AND LEFT AS NEW BEFORE FINAL ACCEPTANCE OF WORK. 10. PERFORM WORK TO COMPLY WITH THE STANDARD PRACTICES FOR GOOD WORKMANSHIP PUBLISHED BY NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION (NECA). COMPLY WITH THE LATEST ENFORCED EDITION OF THE NATIONAL ELECTRICAL CODE (NEC), LOCAL CODES, AMENDMENTS, AND ORDINANCES. 11. PERFORM ELECTRICAL WORK UNDER THE SUPERVISION OF A LICENSED MASTER ELECTRICIAN. PROCURE PERMITS AND LICENSES AND PAY FEES ASSOCIATED WITH THIS WORK. 12. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING ALL DOCUMENTATION REQUIRED TO CITY OF RENTON FOR PERMITTING. COORDINATE WITH ENGINEER FOR ANY ADDITIONAL DOCUMENTATION. 13. PROVIDE NEW, COMMERCIAL GRADE MATERIALS FURNISHED FOR THIS PROJECT THAT ARE FREE OF DEFECTS, AND LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY UNO. 14. CONTRACTOR IS RESPONSIBLE FOR WIRING ELECTRICAL ITEMS SHOWN ON DRAWINGS. 15. PROVIDE 4" MINIMUM CONCRETE BASES (HOUSEKEEPING PADS) UNDER FLOOR MOUNTED ELECTRICAL EQUIPMENT. THIS INCLUDES, BUT IS NOT LIMITED TO SWITCHBOARDS, GENERATORS, TRANSFORMERS, AND MOTOR CONTROL CENTERS. COMPLY WITH REQUIREMENTS FOR EQUIPMENT BASES AND FOUNDATIONS SPECIFIED IN DIVISION 03. 16. COORDINATE ATTACHMENTS TO STRUCTURE TO VERIFY THAT ATTACHMENT POINTS ON EQUIPMENT AND STRUCTURE CAN ACCEPT SEISMIC, WEIGHT, AND OTHER LOADSIMPOSED. 17. MAINTAIN INDICATED FIRE AND SMOKE RATING OF WALLS, PARTITIONS, CEILINGS, AND FLOORS AT ELECTRICAL PENETRATIONS. SEAL PENETRATIONS WITH FIRESTOP MATERIAL. PROVIDE MATERIAL IN ACCORDANCE WITH ASTM E 814 AND UL 1479 3M OR APPROVED. COMPLY WITH REQUIREMENTS SPECIFIED IN DIVISION 07. 18. PROVIDE FIREBLOCKING AND DRAFT STOPPING AT ELECTRICAL PENETRATIONS IN COMBUSTIBLE CONCEALED SPACES PER THE INTERNATIONAL BUILDING CODE. 19. REFER TO TYPICAL DETAILS PROVIDED IN THIS DRAWING SET FOR EQUIPMENT INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR CONFORMANCE WITH DETAILS. 20. LOCATIONS AND SIZES OF FLOOR, WALL, AND ROOF OPENINGS SHALL BE COORDINATED WITH OTHER TRADES INVOLVED. INCLUDE IN THE COST OF ELECTRICAL WORK, CUTTING, CORING, PATCHING AND PAINTING OF EXISTING WALLS, CEILINGS, FLOORS AND ROOFS AS REQUIRED TO ACCOMMODATE WORK AS INDICATED IN THE ELECTRICAL CONTRACT DOCUMENTS, UNLESS SPECIFICALLY SHOWN ON ARCHITECTURAL DRAWINGS. SURVEYED: DESIGNED: NS DRAWN: NS CHECKED: BP APPROVED: BP 21. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFEKEEPING OF THEIR OWN PROPERTY ON THE JOB SITE. OWNER ASSUMES NO RESPONSIBILITY FOR PROTECTION OF PROPERTIES AGAINST FIRE, THEFT AND ENVIRONMENTAL CONDITIONS. 22. CLEAN THE JOB SITE DAILY AND REMOVE FROM THE PREMISES ANY DIRT AND DEBRIS CAUSE BY THE PERFORMANCE OF THE WORK INCLUDED IN THIS CONTRACT. BEFORE SUBSTANTIAL COMPLETION, CLEAN EQUIPMENT, FIXTURES, EXPOSED CONDUIT AND SIMILAR ITEMS. 23. PROVIDE EQUIPMENT THAT FITS INTO THE SPACE ALLOTTED AND ALLOWS ADEQUATE ACCEPTABLE CLEARANCE FOR INSTALLATION, REPLACEMENT, ENTRY, SERVICING AND MAINTENANCE. COORDINATE WITH OTHER TRADES TO ENSURE NO CONFLICT WITH REQUIRED CLEARANCES. 24. BUILDING SPACE IS LIMITED. STRONG ATTENTION TO DETAIL AND CARE MUST BE TAKEN WHEN DEVELOPING SHOP DRAWING SO ROUTING IS COORDINATED WITH OTHER DISCIPLINES. 25. MATERIALS WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. EXISTING ELECTRICAL: 1. WORK SHALL BE PERFORMED IN A CLEAN AND WORKMANLIKE MANNER. CARE SHALL BE EXERCISED TO MINIMIZE ANY INCONVENIENCE OR DISTURBANCE TO OTHER AREAS OF THE BUILDING WHICH ARE TO REMAIN IN OPERATION. ISOLATE WORK AREAS BY MEANS OF TEMPORARY PARTITIONS AND/OR TARPS TO KEEP DUST AND DIRT WITHIN THE CONSTRUCTION AREA. 2. EXISTING MATERIALS THAT ARE REMOVED SHALL NOT BE REUSED IN NEW SYSTEMS, EXCEPT WHERE INDICATED AS BEING RELOCATED. 3. WHERE INDICATED, CONDUIT OR PORTIONS OF CONDUIT SHALL BE REUSED. REFER TO DRAWING PLANS FOR POINTS OF CONNECTIONS. 4. PROVIDE TEMPORARY SUPPORT OF EXISTING ELECTRICAL SYSTEMS WHERE REQUIRED BY DEMOLITION OR ALTERATION OF EXISTING STRUCTURE DURING CONSTRUCTION. COORDINATE WITH GENERAL CONTRACTOR AND PROVIDE ALL NECESSARY CONDUIT AND EQUIPMENT SUPPORTS AND HANGERS TO MAINTAIN INTEGRITY, SAFETY AND PROPER OPERATION OF EXISTING ELECTRICAL SYSTEMS FOR THE DURATION OF THE WORK. DEMOLITION: 1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE DEMOLITION/INSTALLATION OF ELECTRICAL SYSTEMS AND THOSE REQUIRING ELECTRICAL CONNECTIONS TO MAINTAIN NEC REQUIRED CLEARANCES, INCLUDED BY NOT LIMITED TO AREAS ABOVE ACCESSIBLE CEILINGS. 2. COORDINATE WITH OTHER TRADES FOR PROPER DEMOLITION OF EQUIPMENT. CONSULT THE DRAWINGS OF OTHER TRADES OR CRAFTS TO AVOID CONFLICTS WITH EQUIPMENT, ETC. RESOLVE CONFLICTS PRIOR TO ROUGH -IN AND AT NO ADDITIONAL COST TO THE OWNER. 3. TAKE CAUTION IN DEMOLITION OF ELECTRICAL EQUIPMENT. 4. CONTRACTOR SHALL REMOVE AND LEGALLY DISPOSE OF ALL CONDUIT AND EQUIPMENT INDICATED ON DRAWINGS INCLUDING ALL ASSOCIATED HANGERS, WIREMOLD, WIRING, DEVICES, CONTROLS, AND APPURTENANCES ASSOCIATED WITH EACH PIECE OF EQUIPMENT. 5. EXISTING CONTROL PATHWAYS MAY BE RE -USED. COORDINATE CONTROLS DEMO WORK PRIOR TO DEMOLITION. 6. WHERE EXISTING ITEMS PENETRATE A WALL OR ROOF, CONTRACTOR SHALL PROVIDE INFILL AT (E) PENETRATIONS THROUGH WALL/ROOF WITH LIKE MATERIALS. PATCH & REPAIR TO MATCH SURROUNDING SURFACES INCLUDING PAINT. 7. CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT OF EXISTING ELECTRICAL EQUIPMENT WHERE REQUIRED BY DEMOLITION OR ALTERATION OF EXISTING STRUCTURE DURING CONSTRUCTION. COORDINATE WITH GC AND PROVIDE NECESSARY SUPPORTS AND HANGERS TO MAINTAIN INTEGRITY, SAFETY AND PROPER OPERATION OF EXISTING ELECTRICAL SYSTEMS. 8. THE OWNER HAS THE RIGHT TO RETAIN OWNERSHIP OF ANY MATERIALS BEING REMOVED. DELIVER ITEMS TO THE OWNER'S REPRESENTATIVE AS INDICATED IN THE CONTRACT DOCUMENTS. NOTIFY OWNER IN WRITING AT LEAST 7 DAYS IN ADVANCE OF DEMOLITION. SCALE: VERTICAL: NAVD 1988 NONE HORIZONTAL: NAD 1983/1991 CITY OF RENTON ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY T-432616 IN COMPLIANCE WITH CITY OF RENTON STANDARDS HAZEN HIGH SCHOOL MODERNIZATION ELECTRICAL ABBREVIATIONS AND NOTES DATE: 07.11.25 PAGE: E002 SHEET: 0R 69 OF 76 ^T 1 ` 0 C) N , u Co C) 0 I N Q J CID C) C) I 4 N Ir ,/'s