HomeMy WebLinkAboutT-432619DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F DIRECTION GENERAL NOTES:
rAIINI JeLUIrUAIIUNJ: STREET OF STREET OF 1. DOWNTOWN DECORATIVE PEDESTRIAN LUMINAIRES
ALL LUMINAIRE, POLE, CAST ALUMINUM CURB AND TRAFFIC CURB AND TRAFFIC SHALL BE EQUIPPED WITH ALL EQUIPMENT
BASE PARTS, AND ANY ADDITIONAL SIDEWALK SIDEWALK SHOWN ON THIS SHEET
EQUIPMENT MOUNTED ON THE POLE 2. ARTERIAL DECORATIVE PEDESTRIAN LUMINAIRES
SHALL BE FACTORY PRIMED AND POWDER 270 p , 90 270 p 90 SHALL NOT COME EQUIPPED WITH BANNERS AND
COATED TO MATCH FINISH COLOR. 180180, FLOWER BASKET ARMS/BASKETS
DOWNTOWN LOCATION ARTERIAL LOCATION 3. ORIENTATION OF EQUIPMENT FOR DOWNTOWN
ALL BANDING AND ALL OTHER MOUNTING LOCATIONS AND ARTERIAL LOCATIONS SHALL BE
HARDWARE SHALL MATCH FINISH COLOR. ORIENTATION NOTES - DOWNTOWN LOCATIONS ORIENTATION NOTES - ARTERIAL LOCATIONS PER ORIENTATION LOCATION DETAIL, THIS SHEET
• DECORATIVE PEDESTRIAN LUMINAIRES MOUNTED • DECORATIVE PEDESTRIAN LUMINAIRES
FINISH COLOR: RAL 9005TX "JET BLACK", AT 0% UNLESS OTHERWSE NOTED ON PLANS MOUNTED AT 180', UNLESS OTHERWISE
OR APPROVED EQUAL WITH PAINT CHIP. • HANDHOLES MOUNTED AT 180' NOTED ON PLANS
• RECEPTACLE MOUNTED AT 180' HANDHOLES MOUNTED AT 0'
DECORATIVE LUMINAIRE POLE NOTES • CARFLEX CONDUIT AND IRRIGATION HOLE • RECEPTACLE MOUNTED AT 0'
LOCATED AT 0' • CARFLEX CONDUIT AND IRRIGATION HOLE 2'-6"
8 - #5 BARS,
OO ROUND TUBULAR SECTION PLANT SUPPORT BRACKETS MOUNTED AT 90' LOCATED AT 180' EVENLY SPACED
(NO TAPER) & 270'(UNLESS OTHERWISE NOTED ON PLANS) ONE 2" CONDUIT, UNLESS
• BANNER MOUNTED AT 180' STATED OTHERWISE ON THE CENTER
ORIENTATION LOCATION DETAIL PLANS. STUBOUT 1' FROM • CONDUIT
DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS, EDGE OF CONCRETE e IN
TYPE 3 IES DISTRIBUTION, 4000K CCT, 120-277V 4" ALUMINUM POLE TOP CAP WITH FOUNDATION AND CONNECT FOUNDATION
UNIVERSAL DRIVER (750mA OR LOWER), WITH FLAT �(3) SET SCREWS AT 120' APART TO CITY JUNCTION BOX PER
GLASS LENS) BY CYCLONE (OR APPROVED EQUAL) STD PLAN 119 #4 HOOPS ® 12"
DRIVER SHALL BE INTEGRAL TO THE FIXTURE. FOR O ANCHOR BOLT Lu
MOUNTING ARM DETAILS SEE STD PLAN 117.3. WIRING M
PER STD PLAN 119. `i FOUNDATION SECTION . o
X
Q GROUND POLE LL'
O CONDUIT, SEE FOUNDATION TO FOUNDATION ' w
4" O.D. SECTION, THIS SHEET PER STD PLAN =
119 �
F4 TOP OF CONCRETE
2
PAD/SIDEWALK
DOWNTOWN LOCATIONS ONLY. (2) DECORATIVE
,$n BANNER BRACKETS WITH PRESSURE RELEASE
SPRINGS WITH PROTECTIVE RUBBER COATING
DOWNTOWN LOCATIONS ONLY. -
1/2" DIA. HOLES FOR BANNER. SECURE TOP
=______
BANNER BRACKET WITH THROUGH BOLTS AND
SHIM TO LEVEL PER MANUFACTURER'S INST
DOWNTOWN LOCATIONS
ONLY. 2' x 4'
STREET LIGHT STANDARD DECAL
DECORATIVE BANNER
NUMBERING PER STD PLAN 121
EXTERNAL FESTOON CASTING WITH
DOWNTOWN LOCATIONS
LOCKABLE DIE CAST NEMA 3R
ONLY. 2' DECORATIVE
LOCKING, PAINTABLE, WEATHERPROOF,
BANNER ARM WITH FINIAL
IN -USE COVER, MODEL WP101OMC BY
#4 HOOPS ®12"
INTERMATIC (OR APPROVED EQUAL)
MOUNTED TO GFCI RECEPTACLE. PAINT
=_______
8 - #5 BARS, EVENLY
TO MATCH POLE
3" x 5" REINFORCED ALUMINUM DRIP
ma
SPACED
ACCESS HANDHOLE OPENING AND
FLUSH FITTING ALUMINUM DOOR WITH
W
a
2-1/2"
DOWNTOWN LOCATIONS ONLY.
SECURE BOTTOM BANNER
GASKET LOCATED AT 180'
BRACKET WITH 3
a
ADJUSTABLE STAINLESS
114
DOWNTOWN LOCATIONS ONLY.
o
DECORATIVE FLOWER BASKET AND
U } _
J O
ih Z I
a �
J Z
Q
�N
�w
J
�m
w F
d Q
= z
~ J
W J
o a
x
Z V7
CLR
o
() Q d
o w
Z �
0
w
STEEL BANDS AND SHIM TO
LEVEL PER MANUFACTURER'S
INSTRUCTIONS
1" DIA. IRRIGATION
ARMS PER STD PLAN 117.4
o
C)
I 2'-6-r
I
FOUNDATION DETAIL
TAPERED POLE SHAFT
FABRICATED FROM 6063-T4
TUBING HOLE
ALUMINUM TUBE (POLE
ASSEMBLY HEAT TREATED TO
3/8" STEEL PLATE
T6 CONDITION AFTER WELDING)
1-1/8" DIA HOLE (TYP)
ASTM 356, SPLIT CAST
3„
ALUMINUM BASE, 2'-0"
6" O.D. x .250" WALL
BOLT CIRCLE PER STD
TALL, WITH 4" x 8"
TOP OF BASE ACCEPTING 6"
PLAN 117.4
REMOVABLE ACCESS DOOR.
STRAIGHT ROUND POLE
o
SEE STD PLAN 117.4 FOR
SECTION. INSTALL RUBBER
ANCHOR BOLT TEMPLATE DETAIL
ADDITIONAL DETAILS
GASKET AT TOP OF BASE o
3" x 5" REINFORCED ALUMINUM
1.5' MIN.
HANDHOLE OPENING ON POLE WITH
TOP OF FOUNDATION
TO 3.5' MAX FROM
3/8"-16 HOLE FOR A GROUND
CONNECTOR AND FLUSH FITTING
ANCHOR BOLT TEMPLATE, TOTAL,
FACE OF CURB TO
ALUMINUM DOOR WITH GASKET
SEE ANCHOR BOLT TEMPLATE
FACE OF BASE
DETAIL THIS SHEET (TYP)
FABRICATED ALUMINUM oo
BASE PLATE ASSEMBLY ANCHOR BOLT, 4 TOTAL, 1" DIA, oo
PER STD PLAN 117.4 STEEL F1554 OR GRADE 55 (TYP)
TOP OF SIDEWALK OR 1" HEX NUTS (6 REQ'D PER ANCHOR
CONCRETE PAD BOLT), AND FLAT WASHERS (6 REQ'D
o PER ANCHOR BOLT)
FACE OF CU7LEVEL,
ANCHOR BOLT ASSEMBLY DETAIL
CONCRETE PAD OR SIDEWALK FOUNDATION NOTES
PER STD PLAN 120 1. SONOTUBES SHALL NOT BE ALLOWED
IF SURFACE IS L FOUNDATION, SEE THIS SHEET. EDGE OF 2. ALL FOUNDATION HARDWARE SHALL BE HOT -DIPPED GALVANIZED IN
GROUT AT BASE FOUNDATION SHALL BE LOCATED ATACCORDANCE WITH THE LATEST WSDOT STANDARD SPECIFICATION
COVER, PROVIDE 1/SECTION 9-29.6(5) FOUNDATION HARDWARE
T POLE ELEVATION LEAST 5' FROM CITY UTILITIES UNLESS
OTHERWISE APPROVED BY THE CITY FOUNDATION DETAILS
Y o� ARTERIAL A DOWNTOWN STREET STD. PLAN - 117.2
PUBLIC WORKS DECORATIVE PEDESTRIAN
. ° . APPROVED:
DEPARTMENT LUMINAIRE POLE DETAILS " w 7/27/2022
p Martin Pastucha
F N (0 �.",3,�.. oo... DATE
CONDITION OF APPROVAL:
STREETLIGHT FOUNDATION DESIGN ANALYSIS TO BE
SUBMITTED AND APPROVED PRIOR TO INSTALLATION
1TH
45' R 38"
6"
4" OD HOLE
06 5/8" ROADWAY SCALE
04" PEDESTRIAN SCALE
DIRECT ACCESS
TO THE SCREWS
BRACKET
LEADS
THIS SIDE
WIREWAY- TOP VIEW
3"W X 5"H 6061-T6
L 4"W X 6"H - 6061-T6 0.188"
0.188" RECTANGULAR
RECTANGULAR ALUMINUM TUBE
TERMINAL
ALUMINUM TUBE
=
BLOCK
z
12'-0"
CONNECTOR
L_
(LUMINAIRE ARM LENGTH)
Lq
'
1 1/
4'-0"
(LUMINAIRE ARM LENGTH)
/- 60R 46"
/
MAX OPENING
G
FOR WIREWAY
2" TANGENT 6"
13.5"
7_ 5� I i � 4"0 HOLE
Cl n"ui v a u cncl rc n lQo„ TOP LUMINAIRE HOUSING
3.5"0 HOLE
DocuSign Envelope ID: FFASIADCA-DO50-445F-13750-151`9271 FC791
POLE
2 -0
c-D
(LUMINAIRE ARM =
LENGTH) z POLE
`3.5"O
HOLE _ (LUMINAIRE ARM LENGTH)
2" TANGENT r-/�2.5' R "'
z 2
13= _
2
L w
1
HECIANGULAK ALUMINUM IUHE
ALUMINUM FIN WELDED TO
3"W X 5"H 6061-T6 0.188" ARM AND POLE CLAMP
RECTANGULAR ALUMINUM TUBE
_ --
_ WIREWAY SHALL BE SCH40 ALUMINUM PIPE WITH MINIMUM 1"
z ID, AND MAXIMUM 1 1/2" OD. TYPICAL FOR ALL ARMS
6'-0"
(LUMINAIRE ARM LENGTH) ROUND CAP o =
Ln
o PIGTAIL FROM FIXTURE TO
1 16' R 22" ALUMINUM SHROUD o = TERMINAL BLOCK SHALL BE
(BY MANUFACTURER) PROVIDED BY
6>, MANUFACTURER.
MANUFACTURER FOR TERMINAL BLOCK DETAIL,
SHALL WELD SHROUD SEE THIS SHEET
ALL THE WAY
AROUND
'- 4"W X 6"H - 6061-T6 0.188"
RECTANGULAR ALUMINUM TUBE
8'-0"
TO I (LUMINAIRE ARM LENGTH)
1
LUMINAIRE ARM I w
cn
d a:
Q N
LUMINAIRE w
CONDUCTORS, Lio
-STRAIN RELIEF,
SEE NOTE 7
CLAMP -ON TO
LUMINAIRE
30 R 30 SEE STD a DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS,
PLAN 119 z r
Q TYPE 3 IES DISTRIBUTION, 4000K CCT, 120-277V
6" �'L UNIVERSAL DRIVER (750mA OR LOWER), WITH FLAT
GLASS LENS) BY CYCLONE (OR APPROVED EQUAL)
4"0 HOLE DRIVER SHALL BE INTEGRAL TO THE FIXTURE
"
+T�
4"W X 6"H - 6061-T6 0.188" 3 PRONG METAL
RECTANGULAR ALUMINUM TUBE
5BIRD SPIKES
NOTES: ff4.75"- UV PROTECTED
1. STD PLAN 117.1/117.1A ROADWAY SCALE LUMINAIRE ARM LENGTH SHALL BE 10' OR LESS POLYCARBONATE BASE
2. STD PLAN 117.1/117.1A PEDESTRIAN SCALE LUMINAIRE ARM LENGTH SHALL BE 4' OR LESS
3. STD PLAN 117.2 LUMINAIRE ARM LENGTH SHALL BE 4' OR LESS FOR ARTERIAL LOCATIONS, AND 2' FOR DOWNTOWN LOCATIONS
4. LUMINAIRE ARM LENGTH SHALL BE 12' OR LESS FOR TYPE III TRAFFIC SIGNAL POLES
5. POLE AND BRACKET CABLE SHALL BE 10 AWG WITH O.D. LESS THAN 0.5 INCHES
6. BIRD SPIKES SHALL BE REQUIRED ON LUMINAIRE ARM, LUMINAIRE FIXTURE CAP, AND LUMINAIRE/SIGNAL POLE CAP (IF APPLICABLE),
UNLESS OTHERWISE APPROVED BY THE CITY. PAINT TO MATCH LUMINAIRE POLE COLOR
7. ALL LUMINAIRE FIXTURES SHALL INCLUDE STRAIN RELIEF PER STD PLAN 118
Y o� LUMINAIRE AND MOUNTING STD. PLAN- 117.3
d PUBLIC WORKS BRACKET DETAIL APPROVED:
A DEPARTMENT"s 4/4/2024 1 44
FNT� I sno DATE
N.112INN •►
SURVEYED:
DESIGNED:
INS
DRAWN:
INS
CHECKED:
BP
BY DATE AP P R APPROVED'
BP
SCALE:
NONE
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F
VERTICAL* NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
CONSTRUCTION NOTES
1) NO SONATUBE ALLOWED FOR FOUNDATION CONSTRUCTION
2) FOR FOUNDATION AND ANCHOR BOLT DETAILS, SEE STD PLAN 117.2
J¢" FLEXIBLE
2" CONDUIT WITH BELL END,
CONDUIT FOR
FLEXIBLE
SEE STD PLAN 119
IRRIGATION
2" CONDUIT WITH BELL END
CONDUIT FOR
SCH 80 REDUCER
IF SURFACE IS NOT LEVEL
IRRIGATION
IF SURFACE IS NOT LEVEL,
(S X T)
INSTALL GROUT AT BASE OF POLE I
I
SCH 80 REDUCER
(S X T)
INSTALL GROUT AT BASE OF
1" CONDUIT FOR
AND BASE COVER, PROVIDE 1/2"
POLE AND BASE COVER,
IRRIGATION
DIA DRAIN TUBE THROUGH GROUT
1" CONDUIT FOR
PROVIDE 1/2" DIA DRAIN TUBE
MICROTUBING
SEE TYPICAL LIGHTING
IRRIGATION
THROUGH GROUT
MICROTUBING
UNDERGROUND SYSTEM, CITY
MICROTUBING
OF RENTON STD. PLAN 119,
MICROTUBING
SEE TYPICAL LIGHTING
UNDERGROUND SYSTEM, CITY
U
CONCRETE PAD
FOR JUNCTION BOX AND
CONCRETE PAD
OF RENTON STD. PLAN 119,
OR SIDEWALK
WIRING CONFIGURATION.
RECEPTACLE WIRING PER
7r
OR SIDEWALK
FOR JUNCTION BOX AND WIRING
°
PER STD PLAN
PLANS
PER STD PLAN
CONFIGURATION. RECEPTACLE
a'
120
IRRIGATION CONDUIT SHALL BE
c.
WIRING PER PLANS
a
°
ROUTED TO IRRIGATION VALVE
BOX. IRRIGATION EQUIPMENT'
IRRIGATION CONDUIT SHALL BE
SHALL NOT BE INSTALLED IN
ROUTED TO IRRIGATION VALVE
I
ELECTRICAL JUNCTION BOXES
-
c
BOX. IRRIGATION EQUIPMENT
d
c
FOUNDATION PER
SHALL NOT BE INSTALLED IN
°
STD PLAN 117.2
ELECTRICAL JUNCTION BOXES
a
_
ANCHOR BOLT, HEX NUTS,
d
SPREAD
°
°
AND ANCHOR BOLT TEMPLATE
__T
FOUNDATION PER
PER STD PLAN 117.2
STRUCTURAL DESIGN
ANCHOR BOLT, HEX NUTS,
AND ANCHOR BOLT TEMPLATE
a a
APPROVAL FROM CRY OFREMMPUBLICWORIBRRANSPOREATION
PER STD PLAN 117.2
° d .
�BE�MTO���pA��
a
a a.
a d .
CONDUITIANCHOR BOLT DETAIL FOR SPREAD FOUNDATION
CONDUITIANCHOR BOLT DETAIL FOR SHAFT FOUNDATION
Q
Q
tzj
ALUMINUM POLE
SHAFT _
w
18" SPLIT CAST m
ALUMINUM BASE
WITH REMOVABLE
ACCESS DOOR
16-1 /-SPLIT LINE
DRIP MICROTUBING
GASKET OVER HOLE
(TYP)
WITH HOLE FOR
MICROTUBING
2'-0" LONG
DECORATIVE - - - - - - -
- - - -
ALUMINUM PLANT
SUPPORT ARMS
WITH SET SCREWS
OLB LOAD)
(MAX 6;77\
AND FINIAL (TYP) I
I
1" DIA. IRRIGATION I
I
HOLE 'MTH LIQUID
TIGHT FITTING I
I N
FLEXIBLE CONDUIT.
SUPPLY POLE WITH
Y2"FLEXIBLE CONDUIT
FLOWER BASKETS
PROVIDED BY OTHERS I
DOWNTOWN DECORATIVE
FLOWER
BASKET DETAIL
1" THK. ALUMINUM BASE
PLATE
(6061-T6 ALLOY)
ANCHOR BOLTS
PER STD PLAN
117.2
1 1/4" DIA. x 1 5/8" LG.
LT SLOTS
1/2" BOLT CIRCLE
3" x 3" x 4" THK.
JMINUM PL. GUSSETS
)61-T6 ALLOY)
OD. x .250" WALL
JMINUM POLE
,-2" TYP.
c Y ARTERIAL A DOWNTOWN STREET
�\o �� PUBLIC WORKS DECORATIVE PEDESTRIAN STD. PLAN - 117.4
. . APPROVED:
DEPARTMENT LUMINAIRE POLE DETAILS °� 7/27/2022 1
�� N O= Martin Pastucha
'."""°.."s°.. DATE
CITY OF
RENTON
•
Planning/Building/Public Works Dept.
5:
T-432619
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TRANSPORTATION OPERATION ,
cbarnes 08/07/2025 '
HAZEN HIGH SCHOOL MODERNIZATION
ELECTRICAL DETAILS
DATE:
07.11.25
FIELDBOOK:
PAGE:
E901
SHEET: OF,
72 OF 76
u
C)
co
0
C)
N
a
J