Loading...
HomeMy WebLinkAboutT-432619DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F DIRECTION GENERAL NOTES: rAIINI JeLUIrUAIIUNJ: STREET OF STREET OF 1. DOWNTOWN DECORATIVE PEDESTRIAN LUMINAIRES ALL LUMINAIRE, POLE, CAST ALUMINUM CURB AND TRAFFIC CURB AND TRAFFIC SHALL BE EQUIPPED WITH ALL EQUIPMENT BASE PARTS, AND ANY ADDITIONAL SIDEWALK SIDEWALK SHOWN ON THIS SHEET EQUIPMENT MOUNTED ON THE POLE 2. ARTERIAL DECORATIVE PEDESTRIAN LUMINAIRES SHALL BE FACTORY PRIMED AND POWDER 270 p , 90 270 p 90 SHALL NOT COME EQUIPPED WITH BANNERS AND COATED TO MATCH FINISH COLOR. 180180, FLOWER BASKET ARMS/BASKETS DOWNTOWN LOCATION ARTERIAL LOCATION 3. ORIENTATION OF EQUIPMENT FOR DOWNTOWN ALL BANDING AND ALL OTHER MOUNTING LOCATIONS AND ARTERIAL LOCATIONS SHALL BE HARDWARE SHALL MATCH FINISH COLOR. ORIENTATION NOTES - DOWNTOWN LOCATIONS ORIENTATION NOTES - ARTERIAL LOCATIONS PER ORIENTATION LOCATION DETAIL, THIS SHEET • DECORATIVE PEDESTRIAN LUMINAIRES MOUNTED • DECORATIVE PEDESTRIAN LUMINAIRES FINISH COLOR: RAL 9005TX "JET BLACK", AT 0% UNLESS OTHERWSE NOTED ON PLANS MOUNTED AT 180', UNLESS OTHERWISE OR APPROVED EQUAL WITH PAINT CHIP. • HANDHOLES MOUNTED AT 180' NOTED ON PLANS • RECEPTACLE MOUNTED AT 180' HANDHOLES MOUNTED AT 0' DECORATIVE LUMINAIRE POLE NOTES • CARFLEX CONDUIT AND IRRIGATION HOLE • RECEPTACLE MOUNTED AT 0' LOCATED AT 0' • CARFLEX CONDUIT AND IRRIGATION HOLE 2'-6" 8 - #5 BARS, OO ROUND TUBULAR SECTION PLANT SUPPORT BRACKETS MOUNTED AT 90' LOCATED AT 180' EVENLY SPACED (NO TAPER) & 270'(UNLESS OTHERWISE NOTED ON PLANS) ONE 2" CONDUIT, UNLESS • BANNER MOUNTED AT 180' STATED OTHERWISE ON THE CENTER ORIENTATION LOCATION DETAIL PLANS. STUBOUT 1' FROM • CONDUIT DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS, EDGE OF CONCRETE e IN TYPE 3 IES DISTRIBUTION, 4000K CCT, 120-277V 4" ALUMINUM POLE TOP CAP WITH FOUNDATION AND CONNECT FOUNDATION UNIVERSAL DRIVER (750mA OR LOWER), WITH FLAT �(3) SET SCREWS AT 120' APART TO CITY JUNCTION BOX PER GLASS LENS) BY CYCLONE (OR APPROVED EQUAL) STD PLAN 119 #4 HOOPS ® 12" DRIVER SHALL BE INTEGRAL TO THE FIXTURE. FOR O ANCHOR BOLT Lu MOUNTING ARM DETAILS SEE STD PLAN 117.3. WIRING M PER STD PLAN 119. `i FOUNDATION SECTION . o X Q GROUND POLE LL' O CONDUIT, SEE FOUNDATION TO FOUNDATION ' w 4" O.D. SECTION, THIS SHEET PER STD PLAN = 119 � F4 TOP OF CONCRETE 2 PAD/SIDEWALK DOWNTOWN LOCATIONS ONLY. (2) DECORATIVE ,$n BANNER BRACKETS WITH PRESSURE RELEASE SPRINGS WITH PROTECTIVE RUBBER COATING DOWNTOWN LOCATIONS ONLY. - 1/2" DIA. HOLES FOR BANNER. SECURE TOP =______ BANNER BRACKET WITH THROUGH BOLTS AND SHIM TO LEVEL PER MANUFACTURER'S INST DOWNTOWN LOCATIONS ONLY. 2' x 4' STREET LIGHT STANDARD DECAL DECORATIVE BANNER NUMBERING PER STD PLAN 121 EXTERNAL FESTOON CASTING WITH DOWNTOWN LOCATIONS LOCKABLE DIE CAST NEMA 3R ONLY. 2' DECORATIVE LOCKING, PAINTABLE, WEATHERPROOF, BANNER ARM WITH FINIAL IN -USE COVER, MODEL WP101OMC BY #4 HOOPS ®12" INTERMATIC (OR APPROVED EQUAL) MOUNTED TO GFCI RECEPTACLE. PAINT =_______ 8 - #5 BARS, EVENLY TO MATCH POLE 3" x 5" REINFORCED ALUMINUM DRIP ma SPACED ACCESS HANDHOLE OPENING AND FLUSH FITTING ALUMINUM DOOR WITH W a 2-1/2" DOWNTOWN LOCATIONS ONLY. SECURE BOTTOM BANNER GASKET LOCATED AT 180' BRACKET WITH 3 a ADJUSTABLE STAINLESS 114 DOWNTOWN LOCATIONS ONLY. o DECORATIVE FLOWER BASKET AND U } _ J O ih Z I a � J Z Q �N �w J �m w F d Q = z ~ J W J o a x Z V7 CLR o () Q d o w Z � 0 w STEEL BANDS AND SHIM TO LEVEL PER MANUFACTURER'S INSTRUCTIONS 1" DIA. IRRIGATION ARMS PER STD PLAN 117.4 o C) I 2'-6-r I FOUNDATION DETAIL TAPERED POLE SHAFT FABRICATED FROM 6063-T4 TUBING HOLE ALUMINUM TUBE (POLE ASSEMBLY HEAT TREATED TO 3/8" STEEL PLATE T6 CONDITION AFTER WELDING) 1-1/8" DIA HOLE (TYP) ASTM 356, SPLIT CAST 3„ ALUMINUM BASE, 2'-0" 6" O.D. x .250" WALL BOLT CIRCLE PER STD TALL, WITH 4" x 8" TOP OF BASE ACCEPTING 6" PLAN 117.4 REMOVABLE ACCESS DOOR. STRAIGHT ROUND POLE o SEE STD PLAN 117.4 FOR SECTION. INSTALL RUBBER ANCHOR BOLT TEMPLATE DETAIL ADDITIONAL DETAILS GASKET AT TOP OF BASE o 3" x 5" REINFORCED ALUMINUM 1.5' MIN. HANDHOLE OPENING ON POLE WITH TOP OF FOUNDATION TO 3.5' MAX FROM 3/8"-16 HOLE FOR A GROUND CONNECTOR AND FLUSH FITTING ANCHOR BOLT TEMPLATE, TOTAL, FACE OF CURB TO ALUMINUM DOOR WITH GASKET SEE ANCHOR BOLT TEMPLATE FACE OF BASE DETAIL THIS SHEET (TYP) FABRICATED ALUMINUM oo BASE PLATE ASSEMBLY ANCHOR BOLT, 4 TOTAL, 1" DIA, oo PER STD PLAN 117.4 STEEL F1554 OR GRADE 55 (TYP) TOP OF SIDEWALK OR 1" HEX NUTS (6 REQ'D PER ANCHOR CONCRETE PAD BOLT), AND FLAT WASHERS (6 REQ'D o PER ANCHOR BOLT) FACE OF CU7LEVEL, ANCHOR BOLT ASSEMBLY DETAIL CONCRETE PAD OR SIDEWALK FOUNDATION NOTES PER STD PLAN 120 1. SONOTUBES SHALL NOT BE ALLOWED IF SURFACE IS L FOUNDATION, SEE THIS SHEET. EDGE OF 2. ALL FOUNDATION HARDWARE SHALL BE HOT -DIPPED GALVANIZED IN GROUT AT BASE FOUNDATION SHALL BE LOCATED ATACCORDANCE WITH THE LATEST WSDOT STANDARD SPECIFICATION COVER, PROVIDE 1/SECTION 9-29.6(5) FOUNDATION HARDWARE T POLE ELEVATION LEAST 5' FROM CITY UTILITIES UNLESS OTHERWISE APPROVED BY THE CITY FOUNDATION DETAILS Y o� ARTERIAL A DOWNTOWN STREET STD. PLAN - 117.2 PUBLIC WORKS DECORATIVE PEDESTRIAN . ° . APPROVED: DEPARTMENT LUMINAIRE POLE DETAILS " w 7/27/2022 p Martin Pastucha F N (0 �.",3,�.. oo... DATE CONDITION OF APPROVAL: STREETLIGHT FOUNDATION DESIGN ANALYSIS TO BE SUBMITTED AND APPROVED PRIOR TO INSTALLATION 1TH 45' R 38" 6" 4" OD HOLE 06 5/8" ROADWAY SCALE 04" PEDESTRIAN SCALE DIRECT ACCESS TO THE SCREWS BRACKET LEADS THIS SIDE WIREWAY- TOP VIEW 3"W X 5"H 6061-T6 L 4"W X 6"H - 6061-T6 0.188" 0.188" RECTANGULAR RECTANGULAR ALUMINUM TUBE TERMINAL ALUMINUM TUBE = BLOCK z 12'-0" CONNECTOR L_ (LUMINAIRE ARM LENGTH) Lq ' 1 1/ 4'-0" (LUMINAIRE ARM LENGTH) /- 60R 46" / MAX OPENING G FOR WIREWAY 2" TANGENT 6" 13.5" 7_ 5� I i � 4"0 HOLE Cl n"ui v a u cncl rc n lQo„ TOP LUMINAIRE HOUSING 3.5"0 HOLE DocuSign Envelope ID: FFASIADCA-DO50-445F-13750-151`9271 FC791 POLE 2 -0 c-D (LUMINAIRE ARM = LENGTH) z POLE `3.5"O HOLE _ (LUMINAIRE ARM LENGTH) 2" TANGENT r-/�2.5' R "' z 2 13= _ 2 L w 1 HECIANGULAK ALUMINUM IUHE ALUMINUM FIN WELDED TO 3"W X 5"H 6061-T6 0.188" ARM AND POLE CLAMP RECTANGULAR ALUMINUM TUBE _ -- _ WIREWAY SHALL BE SCH40 ALUMINUM PIPE WITH MINIMUM 1" z ID, AND MAXIMUM 1 1/2" OD. TYPICAL FOR ALL ARMS 6'-0" (LUMINAIRE ARM LENGTH) ROUND CAP o = Ln o PIGTAIL FROM FIXTURE TO 1 16' R 22" ALUMINUM SHROUD o = TERMINAL BLOCK SHALL BE (BY MANUFACTURER) PROVIDED BY 6>, MANUFACTURER. MANUFACTURER FOR TERMINAL BLOCK DETAIL, SHALL WELD SHROUD SEE THIS SHEET ALL THE WAY AROUND '- 4"W X 6"H - 6061-T6 0.188" RECTANGULAR ALUMINUM TUBE 8'-0" TO I (LUMINAIRE ARM LENGTH) 1 LUMINAIRE ARM I w cn d a: Q N LUMINAIRE w CONDUCTORS, Lio -STRAIN RELIEF, SEE NOTE 7 CLAMP -ON TO LUMINAIRE 30 R 30 SEE STD a DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS, PLAN 119 z r Q TYPE 3 IES DISTRIBUTION, 4000K CCT, 120-277V 6" �'L UNIVERSAL DRIVER (750mA OR LOWER), WITH FLAT GLASS LENS) BY CYCLONE (OR APPROVED EQUAL) 4"0 HOLE DRIVER SHALL BE INTEGRAL TO THE FIXTURE " +T� 4"W X 6"H - 6061-T6 0.188" 3 PRONG METAL RECTANGULAR ALUMINUM TUBE 5BIRD SPIKES NOTES: ff4.75"- UV PROTECTED 1. STD PLAN 117.1/117.1A ROADWAY SCALE LUMINAIRE ARM LENGTH SHALL BE 10' OR LESS POLYCARBONATE BASE 2. STD PLAN 117.1/117.1A PEDESTRIAN SCALE LUMINAIRE ARM LENGTH SHALL BE 4' OR LESS 3. STD PLAN 117.2 LUMINAIRE ARM LENGTH SHALL BE 4' OR LESS FOR ARTERIAL LOCATIONS, AND 2' FOR DOWNTOWN LOCATIONS 4. LUMINAIRE ARM LENGTH SHALL BE 12' OR LESS FOR TYPE III TRAFFIC SIGNAL POLES 5. POLE AND BRACKET CABLE SHALL BE 10 AWG WITH O.D. LESS THAN 0.5 INCHES 6. BIRD SPIKES SHALL BE REQUIRED ON LUMINAIRE ARM, LUMINAIRE FIXTURE CAP, AND LUMINAIRE/SIGNAL POLE CAP (IF APPLICABLE), UNLESS OTHERWISE APPROVED BY THE CITY. PAINT TO MATCH LUMINAIRE POLE COLOR 7. ALL LUMINAIRE FIXTURES SHALL INCLUDE STRAIN RELIEF PER STD PLAN 118 Y o� LUMINAIRE AND MOUNTING STD. PLAN- 117.3 d PUBLIC WORKS BRACKET DETAIL APPROVED: A DEPARTMENT"s 4/4/2024 1 44 FNT� I sno DATE N.112INN •► SURVEYED: DESIGNED: INS DRAWN: INS CHECKED: BP BY DATE AP P R APPROVED' BP SCALE: NONE ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F VERTICAL* NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM CONSTRUCTION NOTES 1) NO SONATUBE ALLOWED FOR FOUNDATION CONSTRUCTION 2) FOR FOUNDATION AND ANCHOR BOLT DETAILS, SEE STD PLAN 117.2 J¢" FLEXIBLE 2" CONDUIT WITH BELL END, CONDUIT FOR FLEXIBLE SEE STD PLAN 119 IRRIGATION 2" CONDUIT WITH BELL END CONDUIT FOR SCH 80 REDUCER IF SURFACE IS NOT LEVEL IRRIGATION IF SURFACE IS NOT LEVEL, (S X T) INSTALL GROUT AT BASE OF POLE I I SCH 80 REDUCER (S X T) INSTALL GROUT AT BASE OF 1" CONDUIT FOR AND BASE COVER, PROVIDE 1/2" POLE AND BASE COVER, IRRIGATION DIA DRAIN TUBE THROUGH GROUT 1" CONDUIT FOR PROVIDE 1/2" DIA DRAIN TUBE MICROTUBING SEE TYPICAL LIGHTING IRRIGATION THROUGH GROUT MICROTUBING UNDERGROUND SYSTEM, CITY MICROTUBING OF RENTON STD. PLAN 119, MICROTUBING SEE TYPICAL LIGHTING UNDERGROUND SYSTEM, CITY U CONCRETE PAD FOR JUNCTION BOX AND CONCRETE PAD OF RENTON STD. PLAN 119, OR SIDEWALK WIRING CONFIGURATION. RECEPTACLE WIRING PER 7r OR SIDEWALK FOR JUNCTION BOX AND WIRING ° PER STD PLAN PLANS PER STD PLAN CONFIGURATION. RECEPTACLE a' 120 IRRIGATION CONDUIT SHALL BE c. WIRING PER PLANS a ° ROUTED TO IRRIGATION VALVE BOX. IRRIGATION EQUIPMENT' IRRIGATION CONDUIT SHALL BE SHALL NOT BE INSTALLED IN ROUTED TO IRRIGATION VALVE I ELECTRICAL JUNCTION BOXES - c BOX. IRRIGATION EQUIPMENT d c FOUNDATION PER SHALL NOT BE INSTALLED IN ° STD PLAN 117.2 ELECTRICAL JUNCTION BOXES a _ ANCHOR BOLT, HEX NUTS, d SPREAD ° ° AND ANCHOR BOLT TEMPLATE __T FOUNDATION PER PER STD PLAN 117.2 STRUCTURAL DESIGN ANCHOR BOLT, HEX NUTS, AND ANCHOR BOLT TEMPLATE a a APPROVAL FROM CRY OFREMMPUBLICWORIBRRANSPOREATION PER STD PLAN 117.2 ° d . �BE�MTO���pA�� a a a. a d . CONDUITIANCHOR BOLT DETAIL FOR SPREAD FOUNDATION CONDUITIANCHOR BOLT DETAIL FOR SHAFT FOUNDATION Q Q tzj ALUMINUM POLE SHAFT _ w 18" SPLIT CAST m ALUMINUM BASE WITH REMOVABLE ACCESS DOOR 16-1 /-SPLIT LINE DRIP MICROTUBING GASKET OVER HOLE (TYP) WITH HOLE FOR MICROTUBING 2'-0" LONG DECORATIVE - - - - - - - - - - - ALUMINUM PLANT SUPPORT ARMS WITH SET SCREWS OLB LOAD) (MAX 6;77\ AND FINIAL (TYP) I I 1" DIA. IRRIGATION I I HOLE 'MTH LIQUID TIGHT FITTING I I N FLEXIBLE CONDUIT. SUPPLY POLE WITH Y2"FLEXIBLE CONDUIT FLOWER BASKETS PROVIDED BY OTHERS I DOWNTOWN DECORATIVE FLOWER BASKET DETAIL 1" THK. ALUMINUM BASE PLATE (6061-T6 ALLOY) ANCHOR BOLTS PER STD PLAN 117.2 1 1/4" DIA. x 1 5/8" LG. LT SLOTS 1/2" BOLT CIRCLE 3" x 3" x 4" THK. JMINUM PL. GUSSETS )61-T6 ALLOY) OD. x .250" WALL JMINUM POLE ,-2" TYP. c Y ARTERIAL A DOWNTOWN STREET �\o �� PUBLIC WORKS DECORATIVE PEDESTRIAN STD. PLAN - 117.4 . . APPROVED: DEPARTMENT LUMINAIRE POLE DETAILS °� 7/27/2022 1 �� N O= Martin Pastucha '."""°.."s°.. DATE CITY OF RENTON • Planning/Building/Public Works Dept. 5: T-432619 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TRANSPORTATION OPERATION , cbarnes 08/07/2025 ' HAZEN HIGH SCHOOL MODERNIZATION ELECTRICAL DETAILS DATE: 07.11.25 FIELDBOOK: PAGE: E901 SHEET: OF, 72 OF 76 u C) co 0 C) N a J