HomeMy WebLinkAboutR-417319T i O i c) w W 2 0 z 0 w 0 rr z V ) GENERAL CONSTRUCTION NOTES CODE: VAULT STRUCTURAL DESIGN AND CONSTRUCTION SHALL CONFORM TO THE PROVISIONS OF THE 2018IBC AS ADOPTED BY THE CITY OF RENTON, WASHINGTON GENERAL DETAILS: CONSTRUCTION DETAILS NOT FULLY SHOWN OR NOTED SHALL BE SIMILAR TO DETAILS SHOWN FOR SIMILAR CONDITIONS. DISCREPANCIES: THE CONTRACTOR SHALL NOTIFY ENGINEER UPON FINDING ANY DISCREPANCY OR OMISSION IN THE DRAWINGS OR SPECIFICATIONS. SHORING & EXCAVATION: THE CONTRACTOR SHALL BE SOLEY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES, INCLUDING LAGGING, SHORING AND PROTECTION OF ADJACENT PROPERTY, STRUCTURES, STREETS AND UTILITIES. WALL BACKFILL: PRIOR TO BACKFILLING VAULT WALLS THE CONTRACTOR SHALL HAVE PLACED THE LID PLANKS AND PROVIDED A MINIMUM OF 5 DAYS OF CURE ON THE PLANK VOID FILL. BACKFILL SOIL: WALL BACKFILL SHALL BE WELL GRADED FREE DRAINING MATERIAL. BACKFILL SHALL BE PLACED IN ACCORDANCE WITH THE GEOTECHNICAL RECOMMENDATIONS. ALL COMPACTION OCCURING WITHIN 5' OF THE WALL SHALL BE COMPLETED USING HAND OPERATED MACHINERY. PLAN KEYNOTES 5FTx1OFT OPENING TO RECEIVE RAISED OPEN METAL BAR GRATING w/ INTEGRAL 36" x 36" HINGED ACCESS HATCH, SEE AIA/S2 HATCHED AREA REPRESENTS A 2411 WIDE x 12-1/211 THICK CAST IN PLACE CONCRETE BM. 2411 DIAMETER OPENING w/ KNEEWALL TO ACCEPT RISERS, LADDER, RING AND LOCKING MANHOLE COVER PER CIVIL DRAWINGS, SEE 4,5/S1 FOR LID REINF AT OPENING, k 12-1/211 THICK PRECAST HOLLOW CORE PLANK, SEE DESIGN CRITERIA NOTES ON SHEET SS20R PLANK LOADING REQUIREMENTS. i. POUR SLOTS IN TOP OF PLANK. MANUFACTURER TO PROVIDE A MINIMUM OF 2 SLOTS @ EACH END OF EACH PLANK, PLANK MANUFACTURER MAY REQUIRE GROUTING OF ADDITIONAL CELLS BEYOND THE MINIMUM SHOWN. THE GENERAL CONTRACTOR SHALL INCLUDE GROUTING OF THESE ADDITIONAL CELLS IN HIS BID. SEE WALL SECTIONS FOR REINFORCING, i. PROVIDE BLOCKOUTS IN THE EDGE CELL OF THE PLANK PARALLEL TO THE PERIMETER VAULT WALLS. LOCATE BLOCKOUTS APPROXIMATELY AS SHOWN ON THIS PLAN. SEE WALL SECTIONS FOR REINFORCING. SPECIAL INSPECTION PLAN GENERAL: SPECIAL INSPECTION BY A QUALIFIED INSPECTOR IS REQUIRED IN ACCORDANCE WITH THE 2(2018 IBC QUALIFICATION: THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE BUILDING OFFICIAL. REQUIRED VERIFICATION & INSPECTION: THE SPECIAL INSPECTOR SHALL PERFORM THE VERIFICATIONS & INSPECTIONS NOTED IN THE SCHEDULE BELOW INSPECTION & TESTING SCHEDULE TYPES OF WORK FREQ, 2015 IBC SECTION CAST IN PLACE GONG REINFORCING STEEL, PLACEMENT. P 1705.3 INSTALLATION & FASTENING OF PRECAST PANELS P 1705.3 PLACEMENT OF CONCRETE C 1705.3 VERIFYING USE OF REQUIRED DESIGN MIX P 1705.3 TESTING OF THE CONCRETE FOR SPECIFIED STRENGTH, AIR CONTENT AND SLUMP C 1705.3 STRUCTURAL STEEL STRUCTURAL STEEL ( GRATING ) FABRICATION P 1704.2.5 SOILS VERIFICATION OF SOIL -BEARING CAPACITY: INSTALLATION OF DRAINAGE SYSTEM: C 1705.6 PLACEMENT & COMPACTION OF WALL BACKFILL: P 1705.6 FREQUENCY LEGEND C = CONTINUOUS P = PERIODIC SEE REFERENCES AND STANDARDS LISTED WITHIN THE VERIFICATION & INSPECTION SCHEDULE FOR MEANING OF PERIODIC AND CONTINUOUS INSPECTIONS. CERTIFICATE OF COMPLIANCE: THE SPECIAL INSPECTION AGENCY SHALL PROVIDE A FINAL LETTER CERTIFICATE OF COMPLIANCE STATING THAT THE REVIEWED WORK WAS COMPLETED IN ACCORDANCE WITH THE PERMITTED DOCUMENTS. SUBMITTAL OF REPORTS: ALL SPECIAL INSPECTION REPORTS AND TESTING REPORTS SHALL BE SUBMITTED TO THE OWNER, SITE STRUCTURES AND THE BUILDING OFFICIAL BY THE AGENCY PERFORMING THE INSPECTION OR TESTING. OPEN METAL GRATING OPEN METAL GRATING SHALL BE WELDED STEEL BAR GRATING AS SPECIFIED ON THE DRAWINGS. ALL STEEL GRATING AND GRATING COMPONENTS INCLUDING ITEMS EMBEDED WITHIN THE CONCRETE SHALL BE HOT DIPPED GALVANIZED AFTER FABRICATION, SUPPLIER SHALL PROVIDE ALL COMPONENTS NECESSARY TO INSTALL AND SECURE THE GRATING IN PLACE & SHALL PROVIDE SHOP DRAWINGS DETAILING ALL COMPONENTS OF THE INSTALLATION TO THE ENGINEER FOR REVIEW P-RIOR TO FABRICATION, DESIGN CRITERIA VERTICAL LOADS ON VAULT LID: HOLLOW CORE PLANK SCOPE OF WORK: THE WORK INCLUDED IS THE DESIGN, MANUFACTURE AND DELIVERY OF PRECAST PRESTRESSED CONCRETE UNITS. DESIGN PLANK FOR THE UNIFORM LIVE LOAD : = 150PSF MOST CRITICAL OF THE LOADING CONDITIONS AS SHOWN WITHIN THE *HS25 TRUCK WHEEL LOADS : DESIGN CRITERIA NOTE. 13'-611 14' to 301 TRACTOR: THE MANUFACTURER SHALL SUBMIT STRUCTURAL CALCULATIONS AND FRONT AXLE = 10,000 Ib, PLACEMENT DRAWINGS SIGNED BY A WASHINGTON STATE REGISTERED CIVIL ENGINEER FOR REVIEW PRIOR TO FABRICATION. 0 0 o SINGLE REAR AXLE = 40,000 Ib. FRONT REAR REAR TRAILER : THE MANUFACTURER SHALL INSTALL ALL BLOCK OUTS REQUIRED FOR 0 0 o SINGLE REAR AXLE = 40,000 Ib. STRUCTURAL CONNECTIONS AS INDICATED ON THESE DRAWINGS, NO TRACTOR TRAILER OTHER PENETRATIONS ARE ALLOWED WITHOUT THE PRIOR APPROVAL OF THE PLANK MANUFACTURER. DESIGN LIVE LOAD AND TRUCK WHEEL LOAD TO BE APPLIED INDEPENDENTLY AND IN COMBINATION WITH THE SOIL COVER DEAD ALL HOLLOW CORE JOINTS SHALL BE GROUTED IN ACCORDANCE WITH LOAD. THE MANUFACTURER'S RECOMMENDATIONS. IMPACT & FATIGUE: HOLLOW CORE PLANKS BY DUE TO THE LOW SPEEDS OF SERVICE VEHICLES OVER THE LID, AND CONCRETE TECHNOLOGY CORPORATION THE ACCOUOIL NT FOR COVERLOADS TO IMPACT & FATIGUENCREASES IN ARE NOT REQUIRED. STRUCTURAL STEEL RAISED GRATE: MATERIALS: GRATES TO BE DESIGNED FOR HS25 WHEEL LOAD a. STRUCTURAL STEEL SHAPES & PLATES SHALL CONFORM TO ASTM SOIL COVER FOR LID DESIGN: A36. PLANK MANUFACTURER SHALL BE RESPONSIBLE FOR DETERMINING THE b. HOLLOW STRUCTURAL SECTIONS SHALL CONFORM TO ASTM A500 SOIL COVER DEPTHS USED IN THE LID DESIGN BASED ON THE VAULT GRADE B, Fy=42,000PSI. AND FINISHED GRADE ELEVATIONS AS SHOWN ON THE PERMITTED CIVIL WELDING: DWGS. CONFORM TO AWS D1.1 "STRUCTUUAL WELDING CODE - STEEL" SOIL COVER FOR SUBSTRUCTURE DESIGN: WELDERS SHALL BE CERTIFIED IN ACCORDANCE WITH WABO REQUIREMENTS. USE E70 ELECTRODES OF TYPE REQUIRED FOR THE SUBSTRUCTURE WAS DESIGNED FOR A TYPICAL SOIL COVER OF MATERIALS TO BE WELDED, 0.75FT OVER THE ENTIRE VAULT. GALVANIZING: FOUNDATION DESIGN: ALL STEEL SECTIONS SHALL BE HOT DIPPED GALVANIZED AFTER FOUNDATION DESIGN IS BASED ON THE FOLLOWING VALUES PROVIDED IN FABRICATION CONFORMING TO ASM A-125, REPAIRS SHALL CONFORM TO THE GEOTECHNICAL REPORT BY Cobalt Geosciences 6/17/2019 ASTM A-780 USING ZINC RICH PAINT. THE COATING THICKNESS FOR THE PAINT MUST BE 50% MORE THAN THE SURROUNDING COATING ALLOWABLE BEARING PRESSURE: 3000 PSF DENSE NATIVE SOILS THICKNESS, BUT NOT GREATER THAN 4.0 MILS. 3000 PSF USED IN THE DESIGN LATERAL EARTH PRESSURES ON DETENTION VAULT: DRAINED LEVEL BACKFILL AT REST CONDITION: 50 PCF EFW REINFORCING BAR ACTIVE CONDITION: 35 PCF EFW MATERIAL REQUIREMENT: SEISMIC PRESSURE COMPONENT: E = 14H PSF UNIFORM REINFORCING BARS: SATURATED SOIL DENSITY: 125 PCF USE DEFORMED BARS CONFORMING TO ASTM A615, GRADE 60, EXCEPT AS NOTED ON THE DRAWINGS. DEFERRED SUBMITTALS FABRICATION AND PLACING REQUIREMENTS: BENDING: THE FOLLOWING AREAS OF WORK SHALL BE CONSIDERED AS BARS SHALL BE BENT COLD. BARS PARTIALLY EMBEDDED IN "DEFERRED SUBMITTALS" AS DEFINED IN THE 2(2018IBC CONCRETE SHALL NOT BE FIELD BENT UNLESS NOTED OR SHOWN OTHERWISE OR AUTHORIZED BY THE ENGINEER. a. PRECAST PRESTRESSED HOLLOW CORE PLANK PLACING: ALL DEFERRED SUBMITTALS SHALL BEAR THE STAMP AND SIGNATURE REINFORCEMENT SHALL BE SUPPORTED AND TIED TO PREVENT OF A CIVIL ENGINEER LICENSED TO PRACTICE IN THE STATE OF DISPLACEMENT BY CONSTRUCTION LOADS OR BY PLACING OF CONCRETE. WASHINGTON WHO HAS CURRENT DESIGN EXPERIENCE IN THE TYPE OF CONCRETE COVER: WORK REVIEWED. MINIMUM CONCRETE COVER FOR REINF. SHALL BE AS FOLLOWS, UNLESS THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL NOTED OTHERWISE: THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED BY CONCRETE CAST AGAINST EARTH 311 THE ENGINEER OF RECORD, CONCRETE CAST AGAINST FORMS AND CONTRACTOR SHALL SUBMIT REVIEWED DWGS & CALCS TO THE EXPOSED TO EARTH 211 BUILDING OFFICIAL PRIOR TO INSTALLATION, WET SETTINGS: CONCRETE REINFORCEMENT ANCHOR BOLTS, OR ANY EMBEDDED ITEM WITHIN THE CONCRETE, MAY NOT BE SET INTO THE CONCRETE AFTER IT HAS BEEN CONCRETE REQUIREMENTS: POURED WITHIN THE FORMS. LOCATION STRENGTH MAX W/C RATIO LAP SPLICES: WALLS & LID 3000psi 28 DAYS 0.50 LAP ALL BARS 24" MIN UNLESS SHOWN OTHERWISE ON THESE DRAWINGS, FTGS & GRADE SLAB 3000psi 56 DAYS 0.53 AIR CONTENT: GONG. EXPOSED TO WEATHER SHALL CONTAIN 5% +/-1% ENTRAINED AIR. MIX DESIGN: SHALL BE BASED ON FIELD EXPERIENCE OR TRIAL MIXTURES IN CONFORMANCE WITH THE SPECIFICATIONS, SUBMIT MIX DESIGNS TO THE ENGINEER FOR REVIEW PRIOR TO PLACEMENT. EXPOSURE CATEGORIES: FREEZING THAWING FO SULFATE SO IN CONTACT w/ WATER W1 CORROSION PROTECTION C1 MATERIAL REQUIREMENTS: CEMENT: ASTM C150. ADMIXTURES: ACI 301. AGGREGATES: ASTM C33. WATER: ASTM C94. PLACING REQUIREMENTS: PLACING: PLACE CONCRETE AS NEARLY AS PRACTICABLE TO ITS FINAL POSITION TO AVOID SEGREGATION. DEBRIS: REMOVE ALL DEBRIS FROM FORMS PRIOR TO PLACING CONCRETE, CONSOLIDATION: CONSOLIDATE CONCRETE BY SUITABLE MEANS. THOROUGHLY WORK CONCRETE AROUND EMBEDDED ITEMS AND INTO CORNERS OF FORMS, CURING REQUIREMENTS: CURING: CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A SUITABLE PERIOD OF TIME AFTER PLACEMENT. WEATHER CONDITIONS: ADEQUATE PRECAUTIONS SHALL BE TAKEN DURING HOT AND COLD WEATHER IN ACCORDANCE WITH THE SPECIFICATIONS. LID PLANK PLACEMENT: IN NO CASE SHALL THE LID PLANKS BE PLACED BEFORE THE WALLS HAVE BEEN ALLOWED A MINIMUM OF 3 DAYS OF CURE. WHEN AVERAGE AMBIENT TEMPERATURES ARE LESS THAN 50 DEGREES FAHRENHEIT, THE CONTRACTOR MUST ALLOW A MINIMUM CURE TIME OF 7 DAYS OR PROVIDE AN ADDITIONAL SET OF CYLINDERS TO BE BROKEN AT THE TIME OF LID PLACEMENT DEMONSTRATING A MINIMUM CONCRETE STRENGTH OF 1,000 PSI HAS BEEN REACHED. FINISH: a. CONCRETE FINISH TO BE SMOOTH WITH NO FINS, VOIDS, ROCK POCKETS, OR OTHER IRREGULARITIES. b. CONE SNAP TIES ARE REQUIRED AND ARE TO BE REMOVED AND EPDXY SEALED AT ALL INTERIOR AND EXTERIOR WALL SURFACES, NO FLAT TIES ALLOWED. CWA_CONSULTANS (360)-871-5433 PRESSURE RELIEF VALVE PRESSURE RELIEF VALVES SHALL BE 411m TROY MODEL A2580 HYDROSTATIC RELIEF VALVE AND WALL THIMBLE WITH REMOVABLE GRATE. CONTRACTOR MAY SUBMIT ALTERNATE VALVE TYPES FOR CONSIDERATION, SUBMIT ALL DOCUMENTS RELATED TO THE ALTERNATE, INCLUDING INSTALLATION DETAILS TO THE ENGINEER FOR REVIEW. VALVES SHALL BE SHOWN TO OPEN AT A PRESSURE DIFFERENTIAL NOT EXCEEDING 911 OF WATER HEAD, ALTERNATE VALVES SHALL BE FULLY SERVICABLE TO MAINTAIN PROPER OPERATION OVER THE LIFE OF THE STRUCTURE. 03/31 /2025 REVISED PER AGENCY COMMENTS NO. I REVISION GALV. STEEL GRATES r-8" CURB WALL m� TOP OF WALL FLUSH W/FINISH PAVEMENT V 2' MIN SLAB BEAM @ OPENING COVER a VAULT LID NO COVER REQUIRED WHERE VAULT LID HAS VAULT WALL BEEN DESIGNED FOR DIRECT APPLICATION OF HS25 WHEEL LOADING HSS 3" x 3" x 1/8" REMOVABLE STEEL FRAME @ PERIMETER OF HINGED GRATE SECTION 3/8"0 x 3" TITEN SS 2 1/2" SCREW ANCHOR L. 3 1/8" � LEDGER ANGLE 2" x 2" x 3/16" O � O II II O re) M l 1 fV o �o .-I N 1 1/4" GRINDSMOOTH SADDLE SEAT ANGLE 1/8/TYP 2" x 2-1/2" x 3/16" A REMOVABLE FRAME REST NTS SURVEYED: DESIGNED: DRAWN: CWA /23/251 CWA CHECKED: BY I DATE I APPR APPROVED: SCALE: SCALE ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 10, 36"f 36"f GRATE SEC. GRATE SEC. x 8" CURB WALL GALV. STEEL GRATE TOP OF WALL FLUSH W/FINISH PAVEMENT LEDGER PER C/S2 T__�(2) #5 CONTINUOUS e VERT BARS TO MATCH WALL REINFORCEMENT EXTEND CURB VERT. REBAR INTO VAULT LID LID STRUCTURE TYP. a a VAULT WALL 48"f GRATE SEC. \\\ C/S2 GALVANIZED STEEL GRATING\ -19-4 W/ 1-1/4" x 3/16" BRG BARS En 00 PROVIDE 36" x 36" HINGED SECTION GALVANIZED STEEL ANGLE SEAT OF GRATING @ ACCESS LADDER 2" x 2" x 3/16" COPE HORZ. LEG @ LADDER (7�TYPICAL WALL TIE 3/4" = V-0" T&B HSS 3"x3"x1/8"-� 3/16 EA. SIDE 1/8 CBREMOVABLE FRAME CROSS BRACE NTS VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM AOM%k CITY OF RENTON Planning/Building/Public Works Dept. 1-1/4" DEEP STEEL BAR GRATING —8" CONIC WALL u u u 4 °. ° ° 4 d ` ° ° a LEDGER ANGLE a $ ° 4 � 2" x 2" x 3/16" a 3/8" x 3" TITEN SS ° q SCREW ANCHOR @ 6„ oc ad ° n d . ANGLE SUPPORT TO CC WALL ATTACH M ENT NTS R-417319_ ti N co CD CD CD i N A U m co CD CD CD CD O N Q J CD CD CD CD i CD N 19 7 IN COMPLIANCE WITH CITY OF RENTON STANDARDS w DEVELOPMENT ENGINEERING 2 msippo 05/15/2025 ul 0 SUN RIDGE_TOWNHOMES_II STRUCTURAL -DETAILS z 0 (— DATE: 03/23/2025 1 1 1 V FIELDBOOK: Q PAGE: _ DRAWING NO: S2 z D u) SHEET: 1 n OF: 37 J