HomeMy WebLinkAboutT-417301M ti T T RUN NO 0 0 A COPPER WIRING SCHEDULE CONDUIT WIRE 2" SCH 80 2#8 2" SCH 80 LOCATE WIRE ONLY 2" SCH 80 3#2 (POWER) rnnnnnFNT. WITH #8 GROUND WIRE FUTURE STREET LIGHT TO PSE 240V VAULT 2" SCH 80 1 LOCATE WIRE ONLY I SPARE LIGHT FIXTURE SCHEDULE LOCATION OF MANUFACTURER LUMINAIRE LUMEC STREET LIGHT: TR20 80W48LED 4K LE3F UNV BKTX (SEE STANDARD PLAN 117.1, 117.1A, 117.2) SE LUMEC PED LIGHT: TR20 35W32LED 4K LE3F UNV BKTX (SEE PETROVITSKY STANDARD PLAN 117.1, 117.1A, 117.2) ROAD POLE: 40' TAPERED ALUMINUM WITH BASE COVER (SEE STANDARD PLAN 117.1, 117.1 A) CLAMP -ON BRACKET (4'): (SEE STANDARD PLAN 117.3) CLAMP -ON BRACKET (8'): (SEE STANDARD PLAN 117.3) LEGEND ARTERIAL STREET LIGHT POLE, LUMINAIRE, JUNCTION BOX & FOUNDATION. REFERENCE CITY OF RENTON STANDARD PLANS ON SHEETS SL3 AND SL4 AND STREET LIGHT SCHEDULE ON SHEET SL1. IN ADDITION, REFERENCE SECTION 4-6-060 (1) (ILLUMINATION) OF THE CITY OF RENTON GUIDELINES & STANDARDS FOR STREET LIGHTING DESIGN OF RESIDENTIAL AND ARTERIAL STREET. (ORD. SL1 5517, 12-14-2009; ORD. 5675, 12-3-2012) EXISTING PSE LUMINAIRE EX1, EX2 JUNCTION BOX WITH ANTI SLIP LOCKING LID. (SEE WSDOT TYPE 1 J-40.10-02 STANDARD DWGS). PROVIDE 1" TACK WELDS AT BOTH ENDS OF THE J-BOX LID JUNCTION BOX WITH ANTI SLIP LOCKING LID. (SEE WSDOT TYPE 2 a J-40.10-02 STANDARD DWGS). PROVIDE 1" TACK WELDS AT BOTH ENDS OF THE J-BOX LID - UNDERGROUND CONDUIT & WIRE Q CONDUIT/WIRE RUN NUMBER. SEE SCHEDULES ON SHEET SL1 FOR ADDITIONAL INFORMATION SERVICE CABINET & FOUNDATION REFERENCE CITY OF RENTON STANDARD PLANS ON SHEET SL3 AND SL4 STREET LIGHT SCHEDULE STREET POLE ID EASTING NORTHING STATION OFFSET MOUNTING ARM LIGHT NO. STREET NO. ** ** ** HEIGHTS LENGTHS CIRCUIT TYPE/WATT/DIST. LUMINAIRE TYPE BASE EX1 SE PETROVITSKY ROAD EXISTING PSE POLE,ARM AND LUMINAIRE EX2 SE PETROVITSKY ROAD EXISTING PSE POLE,ARM AND LUMINAIRE SL1 SE PETROVITSKY ROAD 4+87 32.8' LT 35-6" / 16-6" 8' STREET/ 1 LED/80W/TYPE III SEE FIXTURE SCHEDULE FIXED 4' SIDEWALK LED/35W/TYPE III THIS SHEET STATIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ANY ADJUSTMENTS WITH ALL TRADES AND ENGINEER PRIOR TO IMPLEMENTING. ** POLE ID, EASTING AND NORTHING VALUES SHALL BE PROVIDED BY ERIC CUTSHALL (CITY OF RENTON) FOR INCORPORATION INTO AS -BUILD PLANS AND INSTALLED BY THE CONTRACTOR IN ACCORDANCE WITH COR STD PLAN 121. TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 tj vv TACOMA, WA 98409-7315 w Phone:253.472.3300 Q TRES WEST www.treswest.com w ENGINEERS ` ViNAL 4/2/2025 1 1 CITY OF RENTON REVISIONS (2/2f NO. I REVISION SURVEYED: DESIGNED: DPH DRAWN: DPH DPH 4/2/25 JCM CHECKED: JCM BY I DATE I APPR APPROVED: JCM GENERAL NOTES 1. ELECTRICAL CONTRACTOR TO FIELD VERIFY AND COORDINATE EXACT LOCATION OF LIGHT POLES AND JUNCTION BOXES PRIOR TO ROUGH -IN. LIGHT POLES AND JUNCTION BOXES SHALL BE LOCATED OUT OF DRIVEWAYS. IN ADDITION, COORDINATE WITH ALL WATERLINES, METERS, SEWER, STORM AND TREE LOCATIONS WHERE APPLICABLE PRIOR TO ROUGH -IN. STREET LIGHT CONSTRUCTION 1. ALL WORKMANSHIP, MATERIALS AND TESTING SHALL BE IN ACCORDANCE WITH WSDOT STANDARDS SPECIFICATIONS AND NATIONAL ELECTRICAL CODE (NEC). 2. ELECTRICAL PERMITS AND INSPECTIONS FROM CITY OF RENTON ARE REQUIRED FOR ALL STREET LIGHTING INSTALLATIONS WITHIN THE CITY OF RENTON. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING PERMITS PRIOR TO CONSTRUCTION. THESE PERMITS ARE AVAILABLE FROM THE ELECTRICAL PERMIT COUNTER AT CITY OF RENTON DEVELOPMENT SERVICES DIVISION 1055 SOUTH GRADY WAY, RENTON, WA 98057. PRIOR TO INSTALLATION OF ANY MATERIALS THE ELECTRICAL CONTRACTOR SHALL SUBMIT A COPY OF THE ELECTRICAL PERMIT AND THE APPROVED PLANS AND DOCUMENTATION. 3. MODIFICATIONS OF ANY PORTION OF THE LIGHTING SYSTEM ARE PROHIBITED WITHOUT PRIOR APPROVAL BY THE CITY. 4. LIGHTING SERVICE CABINET SHALL BE PER CITY OF RENTON STANDARD PLANS. SEE SHEET SL4. 5. SERVICE ENTRANCE CONDUCTORS SHALL BE A MINIMUM SIZE OF #2 COPPER. ALL LIGHTING WIRE SHALL BE STRANDED COPPER WITH A MINIMUM SIZE OF #8 WITH INSULATION SUITABLE OF WET LOCATIONS. PHASING TAPE WILL NOT BE ALLOWED. 6. ALL WIRE SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT WITH A MINIMUM DIAMETER OF 2". SCHEDULE 80 PVC OR GALVANIZED STEEL CONDUIT SHALL BE INSTALLED UNDER ROADWAYS. ALL CONDUIT SHALL BE INSTALLED IN THE "UTILITY DITCH" OR AS OTHERWISE DIRECTED BY THE CITY. 7. ALL SPLICES SHALL BE IN THE THE NEAREST JUNCTION BOX. WIRE NUTS WILL NOT BE ALLOWED. ALL SPLICES WILL BE MADE WITH TYPE C COPPER FITTINGS, CENTERED AND ENCASED IN A 3-M SCOTCHCAST EPDXY KIT, RATED AT 600 VOLTS, TYPE 82-A1, 82-B1 OR CITY APPROVED EQUAL. 8. IF MORE THAN ONE CIRCUIT PASSES THROUGH A JUNCTION BOX, EACH IS TO HAVE A PVC SLEEVE CLEARLY IDENTIFYING THE CIRCUIT. A 500-VOLT MEGGER TEST WILL BE PERFORMED BY THE ELECTRICAL CONTRACTOR ON EACH CIRCUIT BETWEEN CONDUCTOR AND GROUND PRIOR TO ACCEPTANCE OF THE LIGHTING SYSTEM. THE INSULATION RESISTANCE SHALL NOT BE LESS THAN 6 MEGA -OHMS TO GROUND 2,500 FEET AND OVER AND SHALL NOT BE LESS THAN 8 MEGA -OHMS UNDER 2,500 FEET. A FUNCTIONAL TEST SHALL BE PERFORMED TO THE SATISFACTION OF THE CITY, IN WHICH IT IS DEMONSTRATED TO THE CITY THAT EACH AND EVERY PART OF THE SYSTEM FUNCTIONS AS SPECIFIED OR INTENDED HEREIN. SCALE: 1 "=20'-0" ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M • C TY OF RENTON • Planning/Building/Public Works Dept. 9. EACH LUMINAIRE POLE SHALL HAVE AN SEC IN -LINE, FUSED, WATER TIGHT ELECTRICAL DISCONNECT LOCATED AT THE BASE OF THE POLE. ACCESS TO THESE DISCONNECTS SHALL BE THROUGH THE HAND -HOLE ON THE POLE. THE HAND -HOLE SHALL BE FACING AWAY FROM ONCOMING TRAFFIC FROM THE ADJACENT STREET. LOAD SIDE OF IN -LINE FUSE TO LUMINAIRE HEAD SHALL BE POLE AND BRACKET CABLE, TWO CONDUCTOR, 19 STRAND COPPER #10 AND SHALL BE SUPPORTED AT THE END OF THE LUMINAIRE ARM BY AN APPROVED MEANS. FUSE, SIZE, DISCONNECT INSTALLATION AND GROUNDING IN POLE SHALL CONFORM TO WSDOT STANDARDS. 10. JUNCTION BOXES SHALL BE INSTALLED PER WSDOT STANDARD PLAN J-40.10-03 IN ALL STREET LIGHTING INSTALLATIONS. ALL JUNCTION BOXES SHALL HAVE GALVANIZED LIDS. JUNCTION BOX LOCATION SHALL BE APPROVED BY THE CITY PRIOR TO INSTALLATION. NO CONDUIT RUN SHALL BE MORE THAN 200 FEET BETWEEN JUNCTION BOXES. A JUNCTION BOX SHALL BE LOCATED WITHIN 10 FEET OF EACH LUMINAIRE POLE AND AT EVERY ROAD CROSSING. NO CONDUIT SHALL BE INSTALLED IN THE ROADWAY EXCEPT AT DESIGNATED ROAD CROSSINGS CONDUIT ENTERING THE JUNCTION BOX SHALL BE PERPENDICUALR TO THE SIDES OF THE BOX AND A MINIMUM OF 6 BUT NO MORE THAN 8 INCHES BELOW THE LID. BOXES SHALL BE CLEARLY AND INDELIBLY MARKED AS LIGHTING BOXES BY THE LEGEND "L.T." OR "LIGHTING". ALL JUNCTION BOXES SHALL BE SUPPORTED BY A MINIMUM 6-INCH CRUSHED GRAVEL PAD. 11. AFTER INSTALLATION AND BEFORE ACCEPTANCE BY THE CITY, ALL POLES SHALL BE FREE OF DENTS AND MARKS. SONOTUBE SHALL BE REMOVED TO BELOW GROUND LEVEL. POLE BASES SHALL BE GROUTED AND ALL LUMINAIRE HEADS SHALL BE PLUMB AND LEVEL. 12. CONDUIT SHALL EXTEND BETWEEN 3 AND 6 INCHES ABOVE THE CONCRETE BASE. T-417301 N c� O O N LX O M 0 O N Q J LO O O O O N IN COMPLIANCE WITH CITY OF RENTON STANDARDS (j) LLCu DEVELOPMENT ENGINEERING G �� msippo 05/15/2025 O= z SUNRIDGE TOWNHOMES II COVER SHEET [n DATE: w 4/2/2025 (D FIELDBOOK: Q PAGE: DRAWING NO: it SL1 z SHEET: OF: 0 2 37 Cn