HomeMy WebLinkAboutT-417303C'M ti T T 0 F_ DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F ROUND POLE CAP ALUMINIUM SHROUD BY MANUFACTURER DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS, TYPE 3 IES LUMINAIRE ARM LENGTH DISTRIBUTION, 4000K COT, 120-277V UNIVERSAL DRIVER (750mA OR .N PER PLANS, 10' MAX LOWER), WITH FLAT GLASS LENS) BY CYCLONE (OR APPROVED EQUAL) DRIVER SHALL BE INTEGRAL TO THE FIXTURE. FOR MOUNTING ARM . DETAILS SEE STD PLAN 117.3. WIRING PER STD PLAN 119. f� (6) 1.38" DIA. X 2" LONG SLOTTED HOLES N1TH 1 1/4" DIA, 4" HEX PAINT SPECIFICATIONS: 27 JE" HEAD CONNECTING BOLTS AND NUTS ALL LUMINAIRE, POLE, CAST ALUMINUM BASE PARTS, AND A36 STEEL, ANY ADDITIONAL EQUIPMENT MOUNTED ON THE POLE __ �1 J¢° THICK SHALL BE FACTORY PRIMED AND POWDER COATED TO P` BASE PLATE MATCH FINISH COLOR. - ALL BANDING AND ALL OTHER MOUNTING HARDWARE I�'-- 15"0 BOLT CIRCLE SHALL MATCH FINISH COLOR. FINISH COLOR: RAL 9005TX "JET BLACK", OR APPROVED POLE BASE PLATE DETAIL EQUAL WITH PAINT CHIP. FOUNDATION SHALL SUPPORT DECORATIVE LUMINAIRE POLE NOTES POLE SHOWN IN STANDARD PLAN 117.1A O ROUND TUBULAR SECTION (NO TAPER) FOUNDATION, AND ANCHOR BOLT DOME STYLE LED LUMINAIRE DETAILS PER STANDARD PLAN (WATTAGE PER PLANS, TYPE 3 IES 117.1A �- DISTRIBUTION, 4000K OCT, 120-277V w UNIVERSAL DRIVER (750mA OR LOWER), WITH FLAT GLASS LENS) BY o CYCLONE (OR APPROVED EQUAL) DRIVER SHALL BE INTEGRAL TO THE yo• LLo FIXTURE. FOR MOUNTING ARM DETAILS SEE STD PLAN 117.3. WIRING PER 5' 180' 0.- o STD PLAN 119. 4'-0"3 LUMINAIRE ARM o 270' o •DECORATIVE ROADWAY LUMINAIRES ARE MOUNTED AT 0' z o • DECORATIVE PEDESTRIAN LUMINAIRES ARE MOUNTED AT 180' 18" • HANDHOLES ARE MOUNTED AT 180' ORIENTATION LOCATION FOR STREET LIGHT STANDARD DECAL z z NUMBERING DETAIL, REFER TO CITY OF o J RENTON STD PLAN 121 is Y POLE SHAFT FABRICATED FROM 6063-T4 ALUMINUM, HEAT TREATED TO T6 CONDITION AFTER WELDING. 10" O.D. x 0.250" WALL AT c� LLo BOTTOM OF POLE SHAFT, 9.375' O.D. AT 27" 9 X. z UP FROM BUTT OF POLE. TAPERED BETWEEN OCTA ONAL SPLIT LUMINAIRE CONNECTIONS I� 0 o CAST IRON BASE WITH REMOVABLE DECORATIVE BASE COVER PER ACCESS DOOR DETAIL, THIS SHEET Z 4" X 8" REINFORCED ALUMINUM HANDHOLE OPENING WITH 5/16"-18 HOLE FORA CAST ALUMINUM ANCHOR BASE, GROUND CONNECTOR AND FLUSH FITTING � ALUMINUM DOOR W/ GASKET INSTALL ANCHOR BOLT COVERS o G (PROVIDED BY POLE MANUFACTURER) 6" HIGH SIDEWALK 21" `i OR PLANTER STRIP OADWAY DECORATIVE BASE COVER '. R CONCRETE PAD/SIDEWALK PER STD PLAN 120 IF SURFACE IS NOT LEVEL, INSTALL GROUT AT BASE OF POLE AND FOUNDATION PER STRUCTURAL ANALYSIS BASE COVER, PROVIDE 1/2" DIA DRAIN TUBE THROUGH GROUT POLE ELEVATION Y ARTERIAL STREET STD. PLAN - 117.1 PUBLIC WORKS DECORATIVE LUMINAIRE POLE . � . APPROVED: DEPARTMENT DETAILS a7/27/2022 1 Mrtin Pastucha N T 39a�.o..,� DATE DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F SMALL CELL SHROUD BY OTHERS. SHROUD SHALL BE SECURELY FASTENED TO THE TOP OF POLE VIA 'I� 00� A36 STEEL, PAINT SPECIFICATIONS: � NUTS AND BOLTS, MOUNTING DETAILS PER POLE ,"O 1 Ys^ THICK ALL LUMINAIRE, POLE, CAST ALUMINUM I MANUFACTURER. OTHERWSE PROVIDE POLE CAP q' --"y BASE PLATE BASE PARTS, AND ANY ADDITIONAL I ALUMINUM SHROUD EQUIPMENT MOUNTED ON THE POLE (BY MANUFACTURER) 6' - SHALL BE FACTORY PRIMED AND POWDER -� - 15"0 BOLT CIRCLE COATED TO MATCH FINISH COLOR. DOME STYLE LED LUMINAIRE (WATTAGE PER (6) 1.38" DIA. HOLES WITH 1 1/4" _ LUMINAIRE ARM PLANS, TYPE 3 IES DISTRIBUTION, 4000K OCT, DIA, 4" HEX HEAD CONNECTING ALL BANDING AND ALL OTHER MOUNTING u, 120-277V UNIVERSAL DRIVER (750mA OR BOLTS AND NUTS HARDWARE SHALL MATCH FINISH COLOR. -� LEN�PLANS, LOWER), WITH FLAT GLASS LENS) BY CYCLONE (OR APPROVED EQUAL) DRIVER SHALL BEPOLE BASE PLATE DETAIL FINISH COLOR: RAL 9005TX "JET BLACK", INTEGRAL TO THE FIXTURE. FOR MOUNTING ARM S_O" OR APPROVED EQUAL WITH PAINT CHIP DETAILS SEE STD PLAN 117.3. WIRING PER STD PLAN 119. DECORATIVE LUMINAIRE POLE NOTES `i ® ONE 2" CONDUIT, UNLESS STATED _ OTHERWASE ON THE PLANS. STUBOUT 1' OT ROUND TUBULAR SECTION -� FROM EDGE OF CONCRETE FOUNDATION (NO TAPER) AND CONNECT TO CITY JUNCTION BOX PER STD PLAN 119 27 J4" ONE 2" CONDUIT, STUBOUT 1' FROM 1 3 OF POLE SPACE FOR 90' / EDGE OF CONCRETE FOUNDATION, CONNECT TO CARRIER JUNCTION BOX, CARRIER ORIENTED AT 90' OR TYPE 1 OR TYPE 2 JUNCTION BOX 270' FOR LENGTH OF POLE FOUNDATION SECTION o GROUND POLE TO FOUNDATION CONDUITS, SEE FOUNDATION SECTION, PER STD PLAN 119 0' F 180'P21V�, THIS SHEET w w <� ANCHOR BOLTS, SEE ANCHOR BOLT' ASSEMBLY DETAIL, THIS SHEET v' a `i TOP OF CONCRETE PAD/SIDEWALK 2/3 OF POLE SPACE FOR ITY/UTIUTY POLE CHAMBER DETAIL DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS, TYPE 3 IES DISTRIBUTION, 4000K COT, 120-277V UNIVERSAL DRIVER (750mA OR LOWER), WITH FLAT GLASS LENS) BY CYCLONE (OR APPROVED EQUAL) DRIVER SHALL BE INTEGRAL TO THE FIXTURE. 4'-0" FOR MOUNTING ARM DETAILS SEE LUMINAIRE STD PLAN 117.3. WIRING PER STD PLAN 119.E FOR STREET LIGHT STANDARD DECAL NUMBERING DETAIL, REFER TO CITY OF RENTON STD PLAN 121 A595 GR. A. 55KSI, TAPERED STEEL POLE SHAFT, 35.75' LONG, 0.209" THICK, 10.83" BOTTOM O.D., 5.83" TOP O.D. (2) STEEL 4' x 10" HAND HOLE WITH COVER AND NUT HOLDER WITH FASTENERS FOR GROUNDING ALUMINUM BASE COVER, SEE REBAR PER STRUCTURAL ANALYSIS B= U N 3 � z F � �o =P 0 0 � 90• 180 o � I Z o I - 0 270' FOUNDATION DETAIL m • DECORATIVE ROADWAY LUMINAIRES 1.38" DID. HOLE (TYP) ARE MOUNTED AT 0' • DECORATIVE PEDESTRIAN LUMINAIRES 1" THICK STEEL PLATE ARE MOUNTED AT 180' • HANDHOLES ARE MOUNTED AT 180' BOLT CIRCLE PER i POLE BASE PLATE ORIENTATION LOCATION DETAIL, THIS SHEET ANCHOR BOLT TEMPLATE DETAIL TOP OF FOUNDATION ANCHOR BOLT TEMPLATE (TYP) ANCHOR BOLT, 4 TOTAL, 1 K' DIA., STEEL F1554 OR GRADE 55 ia STANDARD DETAIL 117.1E u 6' HIGH SIDEWALK (TYP) i z OR PLANTER STRIP 1 Y.° HEX NUTS (6 REO'D PER ANCHOR BOLT), AND a FLAT WASHERS (6 REQ'D PER -.; --. ROADWAY ANCHOR BOLT) CONCRETE PAD/SIDEWALK PER STD PLAN 120 IF SURFACE IS NOT LEVEL, INSTALL GROUT AT ANCHOR BOLT ASSEMBLY DETAIL SEE FOUNDATION DETAIL, THIS SHEET. EDGE OF BASE OF POLE AND BASE COVER, PROVIDE 1/2' FOUNDATION NOTES FOUNDATION SHALL BE LOCATED AT LEAST 5' DID. DRAIN TUBE THROUGH GROUT 1. SONOTUBES SHALL NOT BE ALLOWED AWAY FROM CITY UTILITIES UNLESS OTHERWISE 2. ALL FOUNDATION HARDWARE SHALL BE HOT -DIPPED GALVANIZED IN APPROVED BY THE CITY ACCORDANCE WATH THE LATEST WSDOT STANDARD SPECIFICATION POLE ELEVATION SECTION 9-29.6(5) FOUNDATION HARDWARE ARTERIAL STREET ®� PUBLIC WORKS SMALL CELL DECORATIVE DEPARTMENT LUMINAIRE POLE DETAILS �FN1o� STD. PLAN - 117.1A APPROVED: 7/27/2022 1 Martin Pastucha DATE SEE DETAIL 1 THIS SHEET FOR THE FOUNDATION DESIGN AND CALCULATION. TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 w Phone:253.472.3300 Q TRES WEST www.treswest.com w ENGINEERS J DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F DIRECTION GENERAL NOTES: rAINI brLUIUAIIUna: STREET OF STREET OF 1. DOWNTOWN DECORATIVE PEDESTRIAN LUMINAIRES ALL LUMINAIRE, POLE, CAST ALUMINUM CURB AND }�} TRAFFIC CURB AND "t TRAFFIC SHALL BE EQUIPPED WITH ALL EQUIPMENT BASE PARTS, AND ANY ADDITIONAL SIDEWAL SIDEWAL SHOWN ON THIS SHEET EQUIPMENT MOUNTED ON THE POLE 2. ARTERIAL DECORATIVE PEDESTRIAN LUMINAIRES SHALL BE FACTORY PRIMED AND POWDER zoo• sn zFo• so• SHALL NOT COME EQUIPPED WITH BANNERS AND COATED TO MATCH FINISH COLOR. FLOWER BASKET ARMS/BASKETS DOWNTOWN LOCATION ARTERIAL LOCATION 3. ORIENTATION OF EQUIPMENT FOR DOWNTOWN ALL BANDING AND ALL OTHER MOUNTING LOCATIONS AND ARTERIAL LOCATIONS SHALL BE HARDWARE SHALL MATCH FINISH COLOR. ORIENTATION NOTES - DOWNTOWN LOCATIONS ORIENTATION NOTES - ARTERIAL LOCATIONS PER ORIENTATION LOCATION DETAIL, THIS SHEET DECORATIVE PEDESTRIAN LUMINAIRES MOUNTED • DECORATIVE PEDESTRIAN LUMINAIRES FINISH COLOR: RAL 9005TX "JET BLACK', AT 0', UNLESS OTHERWISE NOTED ON PLANS MOUNTED AT 180', UNLESS OTHERWISE OR APPROVED EQUAL WITH PAINT CHIP. • HANDHOLES MOUNTED AT 180' NOTED ON PLANS DECORATIVE LUMINAIRE POLE NOTES RECEPTACLE MOUNTED AT 180' HANDHOLES MOUNTED AT 0' CARFLEX CONDUIT AND IRRIGATION HOLE • RECEPTACLE MOUNTED AT 0' 2' 6" LOCATED AT 0' • CARFLEX CONDUIT AND IRRIGATION HOLE 8 - I5 BARS, OT ROUND TUBULAR SECTION PLANT SUPPORT BRACKETS MOUNTED AT 90' LOCATED AT 180' EVENLY SPACED (NO TAPER) & 270- (UNLESS OTHERWISE NOTED ON PLANS) ONE 2" CONDUIT, UNLESS • BANNER MOUNTED AT 180' STATED OTHERWSE ON THE CENTER ORIENTATION LOCATION DETAIL PLANS. STUBOUT 1' FROM ° CONDUIT DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS, EDGE OF CONCRETE IN TYPE 3 IES DISTRIBUTION, 4000K OCT. 120-277V 4" ALUMINUM POLE TOP CAP WITH FOUNDATION AND CONNECT FOUNDATION UNIVERSAL DRIVER (75OmA OR LOWER), WITH FLAT (3) SET SCREWS AT 120- APART TO CITY JUNCTION BOX PER GLASS LENS) BY CYCLONE (OR APPROVED EQUAL) STD PLAN 119 #4 HOOPS D 12" DRIVER SHALL BE INTEGRAL TO THE FIXTURE. FOR © ANCHOR BOLT 1. MOUNTING ARM DETAILS SEE STD PLAN 117.3. WIRING PER STD PLAN 119. FOUNDATION SECTION - o o �w GROUND POLE O CONDUIT, SEE FOUNDATION TO FOUNDATION 4" O.D. SECTION, THIS SHEET PER STD PLAN TOP OF CONCRETE 119 - PAD/SIDEWALK I TOWN LOCATIONS ONLY. (2) DECORATIVE 18" I ER BRACKETS WITH PRESSURE RELEASE GS WITH PROTECTIVE RUBBER COATING DOWNTOWN LOCATIONS ONLY. 1 /2" DIA. HOLES FOR BANNER. SECURE TOP _ BANNER BRACKET WITH THROUGH BOLTS AND J . SHIM TO LEVEL PER MANUFACTURER'S INST z DOWNTOWN LOCATIONS a STREET LIGHT STANDARD DECAL ONLY. 2' x 4' za DECORATIVE BANNER NUMBERING PER STD PLAN 121___-- 21 N w EXTERNAL FESTOON CASTING WITH DOWNTOWN LOCATIONS LOCKABLE DIE CAST NEMA 3R ONLY. 2' DECORATIVE In LOCKING, PAINTABLE, WEATHERPROOF, BANNER ARM WITH FINIAL Y IN -USE COVER, MODEL WP101OMC BY14 HOOPS 012" INTERMATIC (OR APPROVED EQUAL) a j 3 MOUNTED TO GFCI RECEPTACLE. PAINT -------- 8 - 15 BARS, EVENLY o a _ ACE TO MATCH POLE -3" x 5" REINFORCED ALUMINUM DRIP w 2P /2DCLR ACCESS HANDHOLE OPENING AND a a o DOWNTOWN LOCATIONS ONLY. FLUSH FITTING ALUMINUM DOOR WITH a 1. SECURE BOTTOM BANNER GASKET LOCATED AT 180' o o BRACKET WITH 3 DOWNTOWN LOCATIONS ONLY. 5" ADJUSTABLE STAINLESS o DECORATIVE FLOWER BASKET AND STEEL BANDS AND SHIM TO Z ARMS PER STD PLAN 117.4i 2'-6" x LEVEL PER MANUFACTURER'S I '1 INSTRUCTIONS o TAPERED POLE SHAFT FOUNDATION DETAIL m 1" DIA. IRRIGATION FABRICATED FROM 6063-T4 TUBING HOLE ALUMINUM TUBE (POLE ` m ASSEMBLY HEAT TREATED TO 3/8" STEEL PLATE to T6 CONDITION AFTER WELDING) 3"//� 1-1/8' DIA HOLE (TYP) W AM 356, SPLIT CAST 6" O.D. x .250" WALL-�j�'�BOLT CIRCLE PER STD ALULUMINUM BASE, 2'-0" c> TALL, WITH 4" x 8" TOP OF BASE ACCEPTING 6" PLAN 117.4 ` REMOVABLE ACCESS DOOR. STRAIGHT ROUND POLE 'oo SEE STD PLAN 117.4 FOR SECTION. INSTALL RUBBER o ADDITIONAL DETAILS GASKET AT TOP OF BASE o ANCHOR BOLT TEMPLATE DETAIL 3" x 5" REINFORCED ALUMINUM ,0 1.5' MIN. HANDHOLE OPENING ON POLE WITH TOP OF FOUNDATION z TO 3.5' MAX FROM 3/6"-16 HOLE FOR A GROUND FACE OF CURB TO CONNECTOR AND FLUSH FITTING ANCHOR BOLT TEMPLATE, TOTAL, //� FACE OF BASE ALUMINUM DOOR WITH GASKET SEE ANCHOR BOLT TEMPLATE FABRICATED ALUMINUM DETAIL, THIS SHEET (TYP) BASE PLATE ASSEMBLY ANCHOR BOLT, 4 TOTAL, 1" DIA, PER STO PLAN 117.4 E) STEEL F1554 OR GRADE 55 (TYP) TOP OF SIDEWALK OR •i 1" HEX NUTS (6 REQ'D PER ANCHOR CONCRETE PAD BOLT), AND FLAT WASHERS (6 REQ'D HqjV1 PER ANCHOR BOLT) FACE OF CURB " ANCHOR BOLT ASSEMBLY DETAIL CONCRETE PAD OR SIDEWALK FOUNDATION NOTES PER STD PLAN 120 1. SONOTUBES SHALL NOT BE ALLOWED IF SURFACE IS NOT LEVEL, INSTALL FOUNDATION, SEE THIS SHEET. EDGE OF 2. ALL FOUNDATION HARDWARE SHALL BE HOT -DIPPED GALVANIZED IN GROUT AT BASE OF POLE AND BASE FOUNDATION SHALL BE LOCATED AT ACCORDANCE MATH THE LATEST WSDOT STANDARD SPECIFICATION COVER, PROVIDE 1/2" DIA DRAIN TUBE SECTION 9-29.6(5) FOUNDATION HARDWARE THROUGH GROUT POLE ELEVATION LEAST 5' FROM CITY UTILITIES UNLESS OTHERWISE APPROVED BY THE CITY FOUNDATION DETAILS Y ARTERIAL & DOWNTOWN STREET STD. PLAN - 117.2 ®� PUBLIC WORKS DECORATIVE PEDESTRIAN APPROVED: DEPARTMENT LUMINAIRE POLE DETAILS astucha 7/27/2022 1 'A � Martin P DATE DocuSign Envelope ID: FFA9ADCA-D050-445F-B750-15F9271FC791 06 5/8" ROADWAY SCA POLE = 04" PEDESTRIAN SCALE 2-0 CL c DIRECT ACCESS (LUMINAIRE ARM = TO THE SCREWS LENGTH) z POLE 10'-0" ; ,§, JR " CE (LUMINAIRE ARM LENGTH) 2" TANGENT I BRACKET 45'R 38" THISEADS SIE5 6" WIREWAY TOP VIEW 4" OD HOLE Ia a 3"W X 5"H 6061-T6 /4"W X 6"H - 6061-T6 0.188" 00 � 0.188" RECTANGULAR RECTANGULAR ALUMINUM TUBE TERMINAL ALUMINUM TUBE Lo = 12'-0" BLOCK z CONNECTOR (LUMINAIRE ARM LENGTH) POE 1 1/2" 4'-0" u 60' R 46" MAX OPENING (LUMINAIRE ARM LENGTH) FOR WIREWAY 2" TANGENT 6" 13.5" z 7.5' R 4"0 HOLE TOP LUMINAIRE HOUSING N 4"W X CH - 6061-T6 0.188" = 5„ RECTANGULAR ALUMINUM TUBE 3.5"0 HOLE ALUMINUM FIN WELDED TO 3"W X 5"H 6061-T6 0.188" ARM AND POLE CLAMP RECTANGULAR ALUMINUM TUBE --O --------------------------------------- - -- -------------------- ------------------- = WIREWAY SHALL BE SCH40 ALUMINUM PIPE WITH MINIMUM 1" z ID, AND MAXIMUM 1 1/2" OD. TYPICAL FOR ALL ARMS (LUMINAIRE ARM LENGTH) ROUND CAP o = PIGTAIL FROM FIXTURE TO 16' R 22" ALUMINUM SHROUD v= = TERMINAL BLOCK SHALL BE (BY MANUFACTURER) PROVIDED BY 6„ MANUFACTURER. MANUFACTURER FOR TERMINAL BLOCK DETAI 4"0 HOLE SHALL WELD SHROUD SEE THIS SHEET ALL THE WAY AROUND 4"W X CH - 6061-T6 0.188' STRAIN RELIEF, = RECTANGULAR ALUMINUM TUBE SEE NOTE 7 LUMINAIRE ARM z a CLAMP -ON TO 8'-0" ¢ LUMINAIRE n (LUMINAIRE ARM LENGTH) LUMINAIRE w CONDUCTORS, o 30' R 30" SEE STD <} " DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS, PLAN 119 z TYPE 3 IES DISTRIBUTION, 4000K CCT, 120-277V 5" ? UNIVERSAL DRIVER (750mA OR LOWER), WITH FLAT GLASS LENS) BY CYCLONE (OR APPROVED EQUAL) 4"0 HOLE DRIVER SHALL BE INTEGRAL TO THE FIXTURE 5" 4"W X 6"H - 6061-T6 0.188" 1 f 3 PRONG METAL RECTANGULAR ALUMINUM TUBE BIRD SPIKES 4.75" NOTES: UV PROTECTED 1. STD PLAN 117.1/117.1A ROADWAY SCALE LUMINAIRE ARM LENGTH SHALL BE 10' OR LESS POLYCARBONATE BASE 2. STD PLAN 117.1/117.1A PEDESTRIAN SCALE LUMINAIRE ARM LENGTH SHALL BE 4' OR LESS 3. STD PLAN 117.2 LUMINAIRE ARM LENGTH SHALL BE 4' OR LESS FOR ARTERIAL LOCATIONS, AND 2' FOR DOWNTOWN LOCATIONS 4. LUMINAIRE ARM LENGTH SHALL BE 12' OR LESS FOR TYPE III TRAFFIC SIGNAL POLES 5. POLE AND BRACKET CABLE SHALL BE 10 AWG WITH O.D. LESS THAN 0.5 INCHES 6. BIRD SPIKES SHALL BE REQUIRED ON LUMINAIRE ARM, LUMINAIRE FIXTURE CAP, AND LUMINAIRE/SIGNAL POLE CAP (IF APPLICABLE), UNLESS OTHERWISE APPROVED BY THE CITY. PAINT TO MATCH LUMINAIRE POLE COLOR 7. ALL LUMINAIRE FIXTURES SHALL INCLUDE STRAIN RELIEF PER STD PLAN 118 LUMINAIRE AND MOUNTING STD. PLAN- 117.3 ®+ PUBLIC WORKS BRACKET DETAIL APPROVED: p NSo� DEPARTMENT �.0 4/4/2024 DATE 4/2/2025 1 1 CITY OF RENTON REVISIONS (2/2f NO. I REVISION DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F �„ aCKET CABLE, #10 AWG. SPLICES BETWEEN FUSE HOLDER AND LUMINAIRE FIXTURE SHALL NOT BE ALLOWED FUSE KITS QUICK DISCONNECT 3 AMP TO LUMINAIRE IN LINE FUSE KITS S.E.C. OR EQUAL, TO RECEPTACLE ONE PER CURRENT CARRYING 120VAC RECEPTACLE WIRING, IF REFER TO WSDOT LOCKING CONDUCTOR. APPLIES TO LUMINAIRE APPLICABLE. WIRING SIZE PER LID STANDARD DUTY AND RECEPTACLE WIRING CONTRACT JUNCTION BOX TYPES 1 & TO LUMINAIRE 2 STANDARD PLAN J-40.10 GREEN INSULATED WIRE, SIZED SPLICE KITS CLEAR EPDXY SPLICE GROUND LUG TO MATCH THE LARGEST KITS ON ALL THRU WIRE RUNS CURRENT CARRYING CONDUCTOR. SIDEWALK PAD PER SOTD PLAN 120 TERMINATE LUMINAIRE GROUND LUG 24"(MIN) COVER #8 BARE COPPER\� II UFER GROUND, GROUND WIRE GROUND II II NON -INSULATED #4 AWG CLAMP II II STRANDED COPPER, II PROVIDE 3' MIN. SLACK. 1 - EQUIPMENT GROUND 2" PVC CONDUIT II II ROUTE FROM GROUNDING WIRE W/GREEN INSULATION l� �1 LUG TO FOUNDATION REBAR. CONNECT TO FROM SERVICE CABINET, REBAR USING AN ACORN SEE NOTE 2, THIS SHEET 5/8"x8' COPPER CLAD CLAMP 2 - LIGHTING SYSTEM GROUND ROD CONCRETE FOUNDATION WIRES TO CONTACTOR (SIZED AS REQ'D.) 2 - 120VAC RECEPTACLE SYSTEM WIRES TO SERVICE CABINET, IF APPLICABLE (SIZED AS REQ'D.) NOTES: 1. THIS DETAIL DEPICTS THE BASIC LUMINAIRE ELECTRICAL WIRING SYSTEM. ADDITIONAL ELECTRICAL EQUIPMENT MAY VARY. 2. MINIMUM GROUND WIRE SIZE SHALL BE #8, AS SHOWN ABOVE. IF CURRENT CARRYING CONDUCTORS ARE LARGER THAN #8, THE MINIMUM GROUND WIRE SIZE SHALL MATCH THE LARGEST WIRE SIZE OF THE CURRENT CARRYING CONDUCTORS. 3. EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE. 4. IF THE FIXTURE MANUFACTURER HAS MADE PROVISIONS FOR THE ATTACHMENT OF A GROUND WIRE, A GREEN INSULATED WIRE, SIZED TO MATCH THE LARGEST CURRENT CARRYING CONDUCTORS, SHALL BE RUN FROM THE FIXTURE TO THE POLE GROUND LUG. 5. ALL CONDUIT SHALL BE PVC SCHEDULE 80. �Y LUMINAIRE ELECTRICAL STD. PLAN - 119 PUBLIC WORKS WIRING SYSTEM • ° . APPROVED: DEPARTMENT 7/27/2022 1 5 Martin Pastucha LATE DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F 7'-0' LUMINAIRE POLE JUNCTION BOX CONCRETE PAD, PLAN VIEW BROOM FINISH r] LUMINAIRE POLE CONCRETE PAD 4" JUNCTION BOX LUMINAIRE CONCRETE FOUNDATION SIDE VIEW LUMINAIRE CONCRETE PAD DETAIL GENERAL NOTES: 1. LUMINAIRE CONCRETE PAD SHALL BE USED IN AREAS OUTSIDE OF SIDEWALK 2. CONCRETE CLASS FOR LUMINAIRE CONCRETE PAD SHALL BE PER STD PLAN 135 3. TOP OF LUMINAIRE FOUNDATION ELEVATION SHALL BE LOCATED AT BOTTOM OF LUMINAIRE CONCRETE PAD ELEVATION OR BOTTOM OF SIDEWALK ELEVATION 4. LUMINAIRE POLE AND JUNCTION BOX TYPE PER PLAN 5. LUMINAIRE CONCRETE PAD ACCOMMODATES TYPE 1 AND TYPE 2 JUNCTION BOXES ONLY LUMINAIRE POLE JUNCTION BOX CONCRETE SIDEWALK PLAN VIEW PER STD PLAN 102 LUMINAIRE POLE CONCRETE SIDEWALK PER STD PLAN 102 JUNCTION BOX LUMINAIRE CONCRETE FOUNDATION SIDE VIEW LUMINAIRE WITH SIDEWALK DETAIL CONCRETE PAD JUNCTION BOX 1'-0„ PLAN VIEW -0" CONCRETE PAD �I JUNCTION BOX SIDE VIEW INDIVIDUAL JUNCTION BOX PAD DETAIL Y LUMINAIRE CONCRETE STD. PLAN - 120 ®� PUBLIC WORKS PAD/SIDEWALK AND APPROVED: p DEPARTMENT JUNCTION BOX CONCRETE PAD Martin Pastucha 7/27/2022 N10 DATE SURVEYED: DESIGNED: DPH DRAWN: DPH DPH 4/2/25 JCM CHECKED: JCM BY DATE APPR APPROVE JCM SCALE: 1"=20'-O" ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F INSTALL DECAL NUMBERS/LETTERS VERTICALLY. DECAL NUMBERS/LETTERS, SEE NUMBERING EXAMPLE, THIS SHEET. SHALL BE INSTALLED IN DRY WEATHER 50' F OR ABOVE 1 2 3 4 C s 6 z 7 z 0 NUMBERING EXAMPLE MOUNTING HEIGHT DETAIL I-PEDESTRIAN SCALE CURB DECAL TRAFFIC FLOW DECAL ORIFMATION FOR POLES SHOWN ON STD PLAN IIL1 t: 1-PEDESTRIAN PEDESTRIAN SCALE DECAL SCALE GC DECAL URB TRAFFIC TRAFFIC FLOW FLOW DECAL ORIENTATION FOR POLES SHOWN ON STD PLAN 1172 TRAFFIC FLOW DECAL OWENTATOI FOR POLES SHOWN ON STD PLAN 117.1 & 117.1A SCALE CALE LUMINAIRE STANDARD DECAL STD. PLAN - 121 ®� PUBLIC WORKS NUMBERING SYSTEM APPROVED: A DEPARTMENT Martin Pastucha 7/27/2022 1 FN10 DATE 4" CONCRETE PAD OR SIDEWALK REQUIRED SEE ANCHOR BOLT ASSEMBLY DETAIL ./-ON STD. PLAN TOP OF CONCRETE PAD/SIDEWALK let.t 117.1A THIS SHEET /" z il. I IN}DAM. CONCAT- CAP G4t•I -. t ENC, - PRO'.9?E ADDITIONAL Y.ON.- DOT=OR CCARAL4I-2-ATION OR • 1-1 ,i i � z Z SIGNAL CAB_E :VHERE 5140i7N IN THE GONR-IACA �- I I I I '' 1 � ¢ � O_ €XT:NND-HE CONDATI NOR. MlN- THE BEYONDOLL II n ' el u (J LL O 40 . USE TYPE -A Ct'1N7ROLLEO.DEASIT'+• BACKFILL D.DEk IT-R C #LHfX*1 SIYP.j I 1 'i , el alob '° STANDARDS�bf CLAMPCONDUCTORTOSTEEL RtrMFCR(.INL's F-L4R V1mH LISTED I - i �, I I O_ r '$I G '� ❑ . C0NNF=T0JR SLATADLE FOR U'SE EM6ECnEO IN CC,NCRETE I -� v r w _ f r z !2Qr OLEETP.)- CONQRETECLASS4_'&)P < 1 I ( I . � w Need @ least 6 deep 73 5� `kn[.r��-'`�ta y y} R_'.T`.8.. r � a } 3' LgN�^r LON �{r F l I I I F 04/19/2025 7-I-- 21 2' C-R. 1 1 FOR FOOTING CAPACITY USE to 0[ APPROXIMATE CAPACITY OF -� 36" DIA z TAPERED STEEL POST. w 1 - 1' ITYr.; _ SEE SLIP BASE FOR [DETAILS NCT SHC+n: A595 GR. A, 55KSI, IBC EQ 18-3 TOP WIF_W ELEVArm VIEW TAPERED STEEL POLE d=(4.25M/S,b)1'2 ST°RAPTEMPLATEAS$EMBLY FIXED BASE SHAFT, 35.75' LONG, 0.209" M = (d2)(S,b)/4.25 THICK, 10.83" BOTTOM O.D., PER TABLE 1806.2 FOR ALLOW 5.83" TOP O.D. - SOIL BEARING OF 3000 PSF 10" PIPE CAPACITY USE DEPTH = 6' STD PIPE THICKNESS=360", S=29.4 IN' S,=(200)6=1200 PSF DETAIL 1 EFFECTIVE S @ .209" THICK = 17.0 IN' MOMENT CAPACITY IS TA .6)(17.0)/12= 46.8'k USE 2/3 SINCE PIPE IS TAPERED MOM CAP OF FOOTING = 36X120OX3/4.25= 30.5 'k OK DESIGN MOMENT = 30.0'K C TY OF RENTON Planning/Building/Public Works Dept. T-417303 1 LJ 1 10 IN COMPLIANCE WITH CITY OF RENTON STANDARDS w 2i DEVELOPMENT ENGINEERING t �' 0 msippo 05/15/2025 _ Z SUNRIDGE TOWNHOMES II DETAILS O w DATE: 4/2/2025 0 0 FIELDBOOK: PAGE: DRAWING NO: Z S L3 r� V J SHEET: 22 OF: 37