Loading...
HomeMy WebLinkAboutT-417304M T I T 0 m F_ DocuSign Envelope ID: F09FD439-BD22-4654-ABD3-E560AA1 F5959 OZ N o000 0000 r N lV in Z O Q W J W E-0mmw wz0U> ww0E- _=WW Z --QF Fn F' W DO I-Z_ Q Qlb U W N Q 0 O Z O Q U W H 0 Q �z�=� W W d W OfwCIDD� LLI-w0 0w��� W= JU 00E-Q0 W W <0UJ �P_LLYQ JZ_=W Q Tn� CD0<MW CL Z�Z w �LU cn w01- Z LL 2 _ � ¢D'�2Z O O =w OaoJ LL W O 3 � O ZO Lu 0 W W D = of Z d U w Lu Z W U) U) m Z W Z W W W W W 2 2 x P H J09W W Q Z _ J Q w =V Jag R. W w - - 1n 3: O = 0� f� av rof LL' W Z d V.' a a Wm J OaU OLL U V' it N N Z Q a 0 Q F- Z Z < IL In O LU O CL LL to W E- O Z I-\ NW LL CM W Q 2 W J 0 Z_ Tn O 7 N O PUBLIC WORKS SERVICE CABINET PLAN - 122.1 + + .ApPROV D: DEPARTMENT mar in FaStUCjyj8/2021 1 4:? FN�C 44 .. DATE DocuSign Envelope ID: F09FD439-BD22-4654-ABD3-E560AA1F5959 UOMPUINIEIV'1NCHEDULE OMETERBASE: 200 AMP, 4 JAW, MANUAL BYPASS, B-LINE U264 W/ 5T" JAW AT 9:00 POSITION OPANELBOARD: 120/240 VAC, 125 AMP COPPER BUS, 1 PHASE, 3 WIRE, 18 CKT, IOK AIC MAIN BREAKER: 200 AMP FRAME, 200 AMP TRIP, 2 POLE, EATON ED2200 BOLT -ON BRANCH BREAKERS, EATON TYPE BAB: 2 - 20/2 ILLUMINATION A, B 1 - 20/1 ITS 1 - 20/1 GROUND FAULT RECEPTACLE 1 - 40/1 SIGNAL (IF PRESENT) 1 - 40/1 AUXILLIARY SIGNAL (IF PRESENT) 2 - 60/2 SMALL CELL BRANCH 1 - 1511 CONTROL 3 - 20/1 SPARE O CONTACTOR: NEMA LIGHTING RATED, 30 AMP 4 POLE, 120 VAC COIL, SQD 891ODPA34VO2 -I REQUIRED OPHOTO ELECTRIC CELL: 1800 WATT, 120 VAC, TWIST LOCK, ALR #SST-IES-UL MOUNTED INSIDE CABINET BEHIND WIREGLASS WINDOW 50 PHOTO -CELL BYPASS SWITCH: SPDT, 15 AMP, RATED (UP TO) 277 VAC (FED THROUGH TERMINAL BLOCK) OGROUND FAULT RECEPTACLE: 20 AMP, 125 VAC, DUPLEX CABINET: CONSTRUCTION: NEMA TYPE 3R, OUTDOOR PADMOUNT, 1/8" 5052-H32 ALUMINUM CONSTRUCTION, OPEN BOTTOM FRAMED WITH 2" ANGLE, 2 SCREENED AND GASKETED VENTS, REMOVABLE EQUIPMENT MOUNTING PAN, CABINET GROUND WITH MINIMUM BONDING WIRE TO NEUTRAL DOORS: HEAVY-DUTY CONCEALED HINGES (LIFT-OFF TYPE),STAINLESS STEEL VAULT HANDLES WITH ROLLER RODS THAT PROVIDE 3-POINT COMPRESSION ON CLOSED CELL NEOPRENE GASKET, "BEST" LOCK ON LOWER DISTRIBUTION DOOR WITH CARD HOLDER, PADLOCKABLE UPPER METER DOOR WITH POLISHED SAFETY GLASS WINDOW DEADFRONT: HINGED AND SECURED WITH QUARTER -TURN FASTENERS FINISH: MILL FINISH ALUMINUM 1 - REQUIRED UL LISTED PER STANDARD #508A "SUITABLE FOR USE AS SERVICE ENTRANCE" NOTE: 1. SIGNAL BREAKER(S) SHALL BE ADDED WHEN APPLICABLE SERVICE CABINET NOTES PLAN - 122.2 PUBLIC WORKS ��� DEPARTMENT kpp aPl'11IOIV0aattUC"8/2021 1 4 NTH ... DATE TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 w Phone:253.472.3300 Q TRES WEST www.treswest.com ENGINEERS n r ,- D 1211011 I.. 1 • u R/W LINE SIDEWALK CURB q ROADWAY CURB SIDEWALK R/W LINE 10' MIN. CLEARANCE FROM DRIVEWAY ALTERNATE PLAN VIEW 2' TO 4' OVERHANG ,1 H' FACE OF CURB TO CENTER 'SL R W OF POLE ROADWAY SIDE PLANTER STRIP A�'. STREET LIGHT CONDUIT TRENCH DEPTH 24" TYPICAL STREET LIGHT FOUNDATION LOCATION H 25' 1 30' 35' 1 40' 7 7�� 2' TO 4' SL 1 1 W-3" 1 2N-3" 1 28'-3" 33'-3" T 0.188 0.188 0.219 0.219 TAPERED ALUM. POLE 'T' WALL OVERHANG I' ALLOY 6063-T6 SATIN GROUND FINISH 'H' r HANDHOLE 4"x6" OPENING / W/COVER & S.S. SCREWS /GROUND LUG INSIDE POLE INSIDE E�OLE• STREET LIGHT CONDUIT TRENCH DEPTH 24" ALTERNATE STREET CROSS SECTION I 'SL' zY STD. PLAN - 124 + .^ + PUBLIC WORKS LIGHT BASE AND JUNCTION BOX PROVED: ,A= $ DEPARTMENT LOCATION NTH ATE DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F CONDUIT ENTRANCE AREA, SEE NOTE 13, STD PLAN 126.2 ° o�o SEE STD PLAN 126.2 FOR ADDITIONAL NOTES PLAN VIEW SIZE TO FIT SIZE TO FIT CABINET CABINET 6" 6" 1,-0" r 1 1,-0„ L C'4 -GRADE LEVEL CN C14 FRONT VIEW SIDE VIEW ELECTRICAL SERVICE CABINET FOUNDATION SEE STD PLAN 126.2 FOR ADDITIONAL NOTES SHIM TO PLUMB SEE NOTE 3 L3o PIT #4 HOOPS �IIT 4 BAR E�AC CORNER �TO `6"" MIN 1" 3/8" DIAMETER PLASTIC DRAIN SIDE VIEW CABINET DEPTH 1'-6" + 2" 1'-6" - - - I - - #4 BAR EACH + i �� #4 CORNER z m _ _ _ 411 _HOOPS PLAN VIEW CONDUIT ENTRANCE AREA, SEE NOTE 5, STD PLAN 126.2 CONTROLLER CABINET FOUNDATION CABINET FOUNDATION STD. PLAN - 126.1 DETAILS PUBLIC WORKS APPROVED: p DEPARTMENT Martin Pastucha 7/27/2022 1 F N 1 O ��u��" DATE 4/2/2025 1 1 CITY OF RENTON REVISIONS (2/2E NO. I REVISION DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F NOTES 1. WHERE FOUNDATION PAD IS LOCATED WITHIN A SIDEWALK, CONSTRUCT PAD TOP FLUSH WITH SIDEWALK GRADE, OMITTING CHAMFER WHERE TOP AND SIDEWALK ABUT. MOUNT TOP SHALL BE FINISHED BY A CONCRETE CONTRACTOR AND SHALL MEET THE REQUIREMENTS OF SECTION 8-14.3 IN THE WSDOT STANDARD SPECIFICATIONS. 2. PAD MOUNT DESIGN IS TYPICAL. 3. PLACE A SILICONE SEAL BETWEEN THE FOUNDATION AND CABINET. 4. ANCHOR BOLTS AND THEIR SPACING TO BE SUPPLIED BY CABINET MANUFACTURER AND SUBMITTED TO THE ENGINEER FOR APPROVAL. 5. CONDUIT SIZES/QUANTITIES FOR CONTROLLER CABINETS SHALL BE INSTALLED PER THE CONTRACT PLANS, PLUS ONE 2" SPARE CAPPED OUT PAST THE FOUNDATION. 6. CONCRETE CLASS PER STD PLAN 135. 7 2- CO SHALL BE PLACEDFROI ELECTRICAL SERVICE/BBS ELECTRICAL SERVICE/BBS CABINET TD TIT THE LER CABINET. CAB8. EACH CABINET SHALL HAVE A %" DIAMETER PLASTIC DRAIN PIPE. CONTROLLER CABINET 9. LOCATE CONDUITS CENTRALLY WITHIN THE CABINETS. 10. WHEN ALL THREE CABINETS ARE TO BE INSTALLED AND SPACE ALLOWS, A COMBINED FOUNDATION SHALL BE USED. 11. WOODEN SHIMS SHALL NOT BE USED 12. GROUNDING SHALL BE PER WSDOT STANDARD PLAN J-60.05, SHEET 3. SHIM TO PLUMB 13. CONDUIT SIZES/QUANTITIES FOR ELECTRICAL SERVICE CABINETS SHALL SHIM TO PLUMB BE INSTALLED PER THE CONTRACT PLANS, PLUS ONE 2" SPARE CAPPED OUT PAST THE FOUNDATION. SEE NOTE 3 SEE NOTE 3 jM HOOPS SHIM TO PLUMB (EQUAL SPACES) SEE NOTE 3 � IIIIIII IIIIII �2• I I _ ` 6" MIN Ld \EFRQ�NTIEW Li t" TO 2" 3 - #4 REINFORCING BAR (EQUAL SPACES) 3/8" DIAMETER PLASTIC DRAIN (ONE PER CABINET) SEE NOTE 5 SEE NOTE 7 3/8" DIAMETER PLASTIC DRAIN SEE NOTE 13 o:w Z m - �2 N - - 3D Q - - �1� - - - FUm2 'I F ZZro + USao + UU WWU u, HORIZONTAL 0 COMBINED FOUNDATION REINF. BAR DIAGRAM 6 PIECES #4 HOOPS 3 - #4 REINFORCING BAR (EQUAL SPACES) CONTROLLER ELECTRI AL SERVICE BS CABINET CAB, T 10" WIDTH + 1" WIDTH DTH 10" + 2" PLAN VIEW COMBINED CONTROLLER/ELECTRICAL SERVICE/BBS FOUNDATION �Y CABINET FOUNDATION STD. PLAN - 126.2 ° PUBLIC WORKS DETAILS APPROVED: . . DEPARTMENT � 7/27/2022 I � FNZo„,.oPo"w Martin Pastucha DATE DocuSign Envelope ID: 894DB72E-3255-4A63-AOF1-38A20AAF74CA GENERAL NOTES: 1. ALL EXISTING TRANSPORTATION INFRASTRUCTURE FEATURES SHALL BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS). 2. ALL TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 3. ALL EXISTING OR PROPOSED TRANSPORTATION INFRASTRUCTURE FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT PROWAG ADA STANDARDS (I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). 4. ALL NEW TRAFFIC SIGNALS SHALL BE CONSTRUCTED WITH FIBER COMMUNICATION CONNECTION TO CITY OF RENTON TRANSPORTATION FIBER OPTIC NETWORK. 5. ALL TRANSPORTATION INFRASTRUCTURE FEATURES THAT ARE TO BE REMOVED AND REINSTALLED AT A LATER DATE SHALL BE RE -INSTALLED TO CURRENT STANDARDS. 6. ALL CONDUIT SHALL BE PVC SCHEDULE 80. 7. SIGNAL POLE, LUMINAIRE, AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 8. ALL PROPOSED SIGNAL POLE FOUNDATIONS AND EXISTING MODIFIED SIGNAL POLE FOUNDATIONS SHALL INCLUDE A CONCRETE PAD AROUND THE FOUNDATION. PROPOSED OR EXISTING SIDEWALK SHALL BE CONSIDERED PART OF THE FOUNDATION PAD. FOUNDATION PAD SHALL BE AT LEAST 2 FEET OFFSET FROM THE SIGNAL POLE FOUNDATION, AS SPACE ALLOWS OR UNLESS OTHERWISE APPROVED. 9. WHEN THE TRAFFIC SIGNAL IS OPERATIONAL, ALL DETECTION SHALL BE MAINTAINED AND REMAIN FUNCTIONAL FOR ALL SIGNAL PHASES. NEW PERMANENT/TEMPORARY VIDEO DETECTION SHALL BE INSTALLED AND OPERATIONAL PRIOR TO DESTROYING ANY EXISTING DETECTION. 10. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION SYSTEMS ARE SUBJECT TO INSPECTION BY CITY OF RENTON PUBLIC WORKS/TRANSPORTATION MAINTENANCE PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION MAINTENANCE MANAGER OR OTHER TRANSPORTATION REPRESENTATIVE. 11. NEW PTZ CAMERA SHALL BE REQUIRED WHEN A NEW TRAFFIC SIGNAL SYSTEM IS INSTALLED, WHEN LANE CONFIGURATION IS MODIFIED WITH NEW SIGNAL PHASING, AND/OR WHEN EXISTING PTZ CAMERA(S) REQUIRE RELOCATION. 12. ARROW BOARDS SHALL BE REQUIRED TEMPORARY TRAFFIC CONTROL WHEN CLOSING A TRAVEL LANE AND SHALL BE MUTCD COMPLIANT. TRANSPORTATION NOTES STD. PLAN - 135 + PUBLIC WORKS P OVED: A DEPARTMENT :art stucha 5/2/2024 1 F N T DATE SURVEYED: DESIGNED: DPH DRAWN: DPH DPH 4/2/25 JCM CHECKED: JCM BY I DATE A P P R APPROVED: JCM SCALE: 1 "=20'-O" ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M DIAMETER = 7/8" i 4-7/8" 1/4" LOAD FUSE LINE 1/4" 1 1/8" OQ O 1/8" CUTTING RINGS • C TY OF RENTON fw�R Planning/Building/Public Works Dept. FUSE KIT VV T E- 3r LII.0 SPLICE KIT FUSE KIT & SPLICE KIT DETAILS ADOPTED CITY OF RENTON ♦ + STANDARD PLANS 1ST DATE: 04/04 .,�.......... ..., nwr NIAMP• inii CP PCrF•.ICY13 T-417304 N 0 0 0 r N AlJ co Ln 0 0 0 0 IN COMPLIANCE WITH CITY OF RENTON STANDARDS C/) Lu G DEVELOPMENT ENGINEERING F� O msippo 05/15/2025 2 Z O (- W SUNRIDGE TOWNHOMES II DATE: 4/0 /2025 FIELDBOQ PACE: IIr DRAWING NO: Z DETAILS S L4 =) SHEET: 23 OF: 37 r