Loading...
HomeMy WebLinkAboutR-395715[�71�N1j'�U:71»1►1� 'NO TRESPASSING PROTECTED TREE' SIGN POSTED EVERY FEET (MINIMUM OF VEGETATION AND TREE FENCING SHALL BE A MINIMUM OF 6' HIGH TEMPORARY CHAIN LINI FENCING WITH 10' LAC BETWEEN POSTS. r fCU l EU I LU r\UU l LUIVE VVI I fI IIV I flE U/11VUr I UfClr LI IVE - ACTUAL FEEDER ROOTS EXTEND WELL BEYOND DRIP LINE RENTON TREE PRESERVATION DETAIL NTS TREE STAKE ROOTBALL TRUNK TREE STAKE PLASTIC TREE TIES 2"0 WOOD STAKE, STAKES SHOULD BE LOCATED OUTSIDE OF ROOTBALL ROOT FLARE SHALL BE LOCATED ABOVE GROUND LINE 3" MULCH LAYER, KEEP AWAY FROM TREE TRUNK 3" WATER BASIN SCARIFY SIDE & BOTTOM OF PLANTING PIT TO ALLOW FOR ROOT PENETRATION CONCRETE SIDEWALK RECOMPACT SUBGRADE TO PREVENT SETTLING 1. TREE PIT SHALL NOT BE LESS 4. TREE STAKES PERPENDICULAR THAN (3) TIMES ROOT BALL DIA. TO THE PREVAILING WIND 2. CUT ALL TIES AND FOLD BACK BURLAP 5. PLANT TREES 2" HIGHER THAN FROM UPPER 1 /3 OF ROOT BALL DEPTH GROWN IN NURSERY 3. REMOVE ALL PLASTIC AND TWINE TYPICAL DECIDUOUS TREE PLANTING DETAIL NTS 2 l� Lu 2 w m INSTALL GROUNDCOVERS AS SPECIFIED PROTECTION MEASURES DURING CONSTRUCTION: 1. CONSTRUCTION STORAGE PROHIBITED: DO NOT FILL, EXCAVATE, STACK OR STORE ANY EQUIPMENT, DISPOSE OF ANY MATERIALS, SUPPLIES OR FLUIDS, OPERATE ANY EQUIPMENT, INSTALL IMPERVIOUS SURFACES, OR COMPACT THE EARTH IN ANY WAY WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO BE RETAINED. 2. FENCED PROTECTION AREA REQUIRED:PRIOR TO DEVELOPMENT ACTIVITIES, A 6' HIGH CHAIN LINK TEMPORARY CONSTRUCTION FENCING AROUND THE DRIP LINES OF ALL RETAINED TREES OR AT A DISTANCE SURROUNDING THE TREE EQUAL TO ONE AND ONE -QUARTER FEET FOR EVERY ONE INCH OF TRUNK CALIPER, WHICHEVER IS GREATER, OR ALONG THE PERIMETER OF A TREE PROTECTION TRACT. PLACECARDS SHALL BE PLACED ON FENCING IF LESS THAN 50' INDICATING THE WORDS, 'NO TRESPASSING -PROTECTED TREES' OR ON EACH SIDE OF THE FENCING IS LESS THAN 50'. SITE ACCESS TO INDIVIDUALLY PROTECTED TREES OR GROUPS OF TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREES SHALL BE FENCED ON 4 SIDES. 3. PROTECTION FROM GRADE CHANGES: IF THE GRADE LEVEL ADJOINING TO A TREE TO BE RETAINED IS TO BE RAISED, A DRY ROCK WALL OR ROCK WELL SHALL BE CONSTRUCTED AROUND THE TREE. THE DIAMETER FO THIS WALL OR WELL MUST BE EQUAL TO THE TREE'S DRIP LINE. 4. MULCH LAYER REQUIRED; ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE COVERED COMPLETELY AND EVENLY WITH A MINIMUM OF 3" OF BARK MULCH PRIOR TO INSTALLATION OF THE PROTECTIVE FENCING. L=ANDS�AFE NOTES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH ALL OTHER SITE IMPROVEMENTS AND CONDITIONS PRIOR TO STARTING LANDSCAPE WORK. 2. CONTRACTOR SHALL USE CAUTION WHILE EXCAVATING TO AVOID DISTURB 1 NG ANY UTILITIES ENCOUNTERED. CONTRACTOR 15 TO PROMPTLY ADVISE OWNER OF ANY DISTURBED UTILITIES. LOCATION SERVICE PHONE -800-424-5555. 5. CONTRACTOR SHALL MAINTAIN AND WATER ALL PLANT MATERIAL FOR I YEAR OR UNTIL FINAL INSPECTION AND ACCEPTANCE BY OWNER. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING OUANT1 TI ES OF PLANTS THAT ARE REPRESENTED BY SYMBOLS ON THE DRAWING. 5. SUBGRADE 15 TO BE WITHIN io INCH OF I FOOT AS PROVIDED BY OTHERS. ALL PLANTING AREAS TO BE CLEARED OF ALL CONSTRUCTION MATERIAL AND ROCKS $ STICKS LARGER THAN 2 INCH DIAMETER. 6. 4 INCH DEPTH TOPSO 1 L IN LANDSCAPE AREA. 7. SHRUBS IN BEDS TO INCLUDE A LAYER OF MULCH AT LEAST 2-INCHE5 IN DEPTH PER RMG 4-4-070 8. 5 INCH DEPTH, 3 FOOT RADIUS REQU I RED FOR MULCH AROUND TREES PER 4-4-0701.0 . cl. GROUND COVERS SHALL BE PLANTED IN AN EQU I LATERAL TRIANGULAR SPACING PATTERN AT THE ON -CENTER DISTANCES SHOWN ON THE PLAN OR IN THE PLANT SCHEDULE. WHERE GROUND COVER ABUTS CURBING, SIDEWALKS, SIGNS OR POLES, MINIMUM PLANTING DISTANCES SHALL BE 12" FROM CENTER OF PLANT TO CURB, SIDEWALK, ETC. MINIMUM PLANTING DISTANCE SHALL BE 24" FROM CENTER OF TREES AND SHRUBS. 10. ALL PLANT MATERIAL SHALL BE FERTILIZE]:;) WITH AGRO TRANSPLANT FERTILIZER 4-2-2 PER MANUFACTURERS #10 GAUGE SPECIFICATIONS. IYL HOSE OINT5 11. ALL PLANT MATERIAL SHALL CONFORM TO AAN STANDARDS FOR NURSERY STOOK LATEST EDITION. ALL PLANT QUAL 5PACED MATERIAL FURNISHED SHALL BE HEALTHY REPRESENTATIVES, TYPICAL OF THEIR SPECIES OF VARIETY AND SHALL HAVE A NORMAL GROWTH HABIT. THEY SHALL BE FULL, WELL BRANCHEID, WELL PROPORTIONED, AND HAVE A VIGOROUS WELL DEVELOPED ROOT SYSTEM. ALL PLANTS SHALL BE HARDY UNDER CLIMATIC CONDITIONS SIMILAR TO THOSE IN THE LOCALITY OF THE PROJECT. TREES, SHRUBS AND GROUNDCOVER OUANT1 TI ES, SPECIES, VARIETIES, ;)E OF MULCH SIZES AND CONDITIONS TO BE AS SHOWN ON THE PLANTING PLAN. PLANTS TO BE FREE OF DISEASE, INJURY, INSECTS, DECAY, HARMFUL DEFECTS AND ALL WEEDS. NO SUBSTITUTIONS SHALL BE MADE WITHOUT WRITTEN APPROVAL FROM TAKE LANDSCAPE ARCHITECT O OWNER. =D :5 OCCUR EA5, PROVIDE ,H CIRCLE. TYPICAL EVERGREEN TREE PLANTING DETAIL NTS SCORE ROOTBALL 3 PLACES TO 1/2" DEPTH INSTALL 1" ABOVE CONTAINER DEPTH mr.,■.. PLAN VIEW OF SPACING TOP DRESSING FERTILIZER AS SPECIFIED ULCH. VERIFY SAUCER PLANTING FERTILIZER AROUND ROOTBALL BACKFILL W/ APPROVED TOPSOIL TYPICAL GROUNDCOVER PLANTING DETAIL NTS NLMUVL IJUKLI TWINE OFF TO[ OF ROOTBALL 2. I RR 1 GAT I ON PLAN PER RMG 4-4-0701 TO BE SUBMITTED AT A LATER DATE AS COORDINATED WITH THE CITY. 15. THE AVERAGE SPACING FOR STREET TREES SHOULD BE 40 FEET ON CENTER AND ADJUSTED TO ALLOW FOR S I GHT LINES, UTILITIES, TRAFFIC SIGNS, L 1 GHT STANDARDS, DRIVEWAYS AND OTHER STREET APPURTENANCES. 14. TREES IN THE RIGHT OF WAY MUST BE PLANTED TO THE FOLLOWING STANDARDS: PLANT TREES IN THE CENTER OF THE PLANTING STRIP WIDTH. & FEET FROM FIRE HYDRANTS AND UNDERGROUND UTILITIES (i e> WATER, SEWER, ELECTRIC, GAS). 10 FEET FROM UTILITY POLES, DRIVEWAYS, AND ALLEY MARL 1 N, 25 FEET FROM STREET L 1 GHTS, 40 FEET FROM THE CORNER OF INTERSECTIONS, STOP SIGNS, AND YIELD SIGNS. AT LEAST 72 HOURS BEFORE YOU PLAN TO DIG, YOU MUST GALL 811 TO REQUEST THAT THE LAST LOCATION OF ANY UNDERGROUND OR OVERHEAD UTILITIES (GAS, WATER, ELECTRIC, ETC.) BE MARKED ON YOUR PLANTING AREA. KNOWING THESE LOCATIONS IN ADVANCE MAY SAVE YOU TIME AND MONEY BY PREVENTING AN ACCIDENT. TYPICAL SHRUB PLANTING DETAIL NTS 3-4" MULCH FINISH GRADE EAK SIDES & ITTOMS OF PLANTING f TO ALLOW FOR IOT PENETRATION ECOMPACT SUBGRADE ELOW ROOT BALL TO ENSURE THAT ROOT FLARE WILL NOT SETTLE BELOW GROUND LINE Emherre:ra T PLANNING :0] 10/20/2017 U3 00 ZUconOLo ~WE-+OON W000 ZUg"�N �aQa� � W Z N x OUd''E-I U cn N Q ZAOG�1 Z O Coe)d0 W W A W U a Q STATE OF WASHINGTON REGISTERED DSCAPE ARCHITECT L90AYLE L. CRAMER CERTIFICATE NO. 634 O H C.7 z V) m W � OA z > W Oo rl W O� z V) Oo Z W/ Z 0 z W SHEET L-03 RECORD DRAWING NO CHANGES OF 3 SHEETS