HomeMy WebLinkAboutR-395715[�71�N1j'�U:71»1►1�
'NO TRESPASSING
PROTECTED TREE'
SIGN POSTED EVERY
FEET (MINIMUM OF
VEGETATION AND TREE
FENCING SHALL BE A
MINIMUM OF 6' HIGH
TEMPORARY CHAIN LINI
FENCING WITH 10' LAC
BETWEEN POSTS.
r fCU l EU I LU r\UU l LUIVE VVI I fI IIV I flE U/11VUr I UfClr LI IVE -
ACTUAL FEEDER ROOTS EXTEND WELL BEYOND DRIP LINE
RENTON TREE PRESERVATION DETAIL
NTS
TREE STAKE
ROOTBALL
TRUNK
TREE STAKE
PLASTIC TREE TIES
2"0 WOOD STAKE, STAKES SHOULD
BE LOCATED OUTSIDE OF ROOTBALL
ROOT FLARE SHALL BE LOCATED
ABOVE GROUND LINE
3" MULCH LAYER, KEEP AWAY
FROM TREE TRUNK
3" WATER BASIN
SCARIFY SIDE & BOTTOM OF
PLANTING PIT TO ALLOW FOR
ROOT PENETRATION
CONCRETE SIDEWALK
RECOMPACT SUBGRADE
TO PREVENT SETTLING
1. TREE PIT SHALL NOT BE LESS 4. TREE STAKES PERPENDICULAR
THAN (3) TIMES ROOT BALL DIA. TO THE PREVAILING WIND
2. CUT ALL TIES AND FOLD BACK BURLAP 5. PLANT TREES 2" HIGHER THAN
FROM UPPER 1 /3 OF ROOT BALL DEPTH GROWN IN NURSERY
3. REMOVE ALL PLASTIC AND TWINE
TYPICAL DECIDUOUS TREE PLANTING DETAIL
NTS
2
l�
Lu
2
w
m
INSTALL GROUNDCOVERS
AS SPECIFIED
PROTECTION MEASURES DURING CONSTRUCTION:
1. CONSTRUCTION STORAGE PROHIBITED: DO NOT FILL, EXCAVATE, STACK OR
STORE ANY EQUIPMENT, DISPOSE OF ANY MATERIALS, SUPPLIES OR FLUIDS,
OPERATE ANY EQUIPMENT, INSTALL IMPERVIOUS SURFACES, OR COMPACT THE
EARTH IN ANY WAY WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO
BE RETAINED.
2. FENCED PROTECTION AREA REQUIRED:PRIOR TO DEVELOPMENT ACTIVITIES, A 6'
HIGH CHAIN LINK TEMPORARY CONSTRUCTION FENCING AROUND THE DRIP LINES
OF ALL RETAINED TREES OR AT A DISTANCE SURROUNDING THE TREE EQUAL TO
ONE AND ONE -QUARTER FEET FOR EVERY ONE INCH OF TRUNK CALIPER,
WHICHEVER IS GREATER, OR ALONG THE PERIMETER OF A TREE PROTECTION
TRACT. PLACECARDS SHALL BE PLACED ON FENCING IF LESS THAN 50' INDICATING
THE WORDS, 'NO TRESPASSING -PROTECTED TREES' OR ON EACH SIDE OF THE
FENCING IS LESS THAN 50'. SITE ACCESS TO INDIVIDUALLY PROTECTED TREES OR
GROUPS OF TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREES SHALL BE
FENCED ON 4 SIDES.
3. PROTECTION FROM GRADE CHANGES: IF THE GRADE LEVEL ADJOINING TO A TREE
TO BE RETAINED IS TO BE RAISED, A DRY ROCK WALL OR ROCK WELL SHALL BE
CONSTRUCTED AROUND THE TREE. THE DIAMETER FO THIS WALL OR WELL MUST
BE EQUAL TO THE TREE'S DRIP LINE.
4. MULCH LAYER REQUIRED; ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE
COVERED COMPLETELY AND EVENLY WITH A MINIMUM OF 3" OF BARK MULCH
PRIOR TO INSTALLATION OF THE PROTECTIVE FENCING.
L=ANDS�AFE NOTES:
1. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH ALL OTHER SITE IMPROVEMENTS AND
CONDITIONS PRIOR TO STARTING LANDSCAPE WORK.
2. CONTRACTOR SHALL USE CAUTION WHILE EXCAVATING TO AVOID DISTURB 1 NG ANY UTILITIES ENCOUNTERED.
CONTRACTOR 15 TO PROMPTLY ADVISE OWNER OF ANY DISTURBED UTILITIES. LOCATION SERVICE PHONE
-800-424-5555.
5. CONTRACTOR SHALL MAINTAIN AND WATER ALL PLANT MATERIAL FOR I YEAR OR UNTIL FINAL INSPECTION AND
ACCEPTANCE BY OWNER.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING OUANT1 TI ES OF PLANTS THAT ARE REPRESENTED BY
SYMBOLS ON THE DRAWING.
5. SUBGRADE 15 TO BE WITHIN io INCH OF I FOOT AS PROVIDED BY OTHERS. ALL PLANTING AREAS TO BE CLEARED
OF ALL CONSTRUCTION MATERIAL AND ROCKS $ STICKS LARGER THAN 2 INCH DIAMETER.
6. 4 INCH DEPTH TOPSO 1 L IN LANDSCAPE AREA.
7. SHRUBS IN BEDS TO INCLUDE A LAYER OF MULCH AT LEAST 2-INCHE5 IN DEPTH PER RMG 4-4-070
8. 5 INCH DEPTH, 3 FOOT RADIUS REQU I RED FOR MULCH AROUND TREES PER 4-4-0701.0 .
cl. GROUND COVERS SHALL BE PLANTED IN AN EQU I LATERAL TRIANGULAR SPACING PATTERN AT THE ON -CENTER
DISTANCES SHOWN ON THE PLAN OR IN THE PLANT SCHEDULE. WHERE GROUND COVER ABUTS CURBING, SIDEWALKS,
SIGNS OR POLES, MINIMUM PLANTING DISTANCES SHALL BE 12" FROM CENTER OF PLANT TO CURB, SIDEWALK, ETC.
MINIMUM PLANTING DISTANCE SHALL BE 24" FROM CENTER OF TREES AND SHRUBS.
10. ALL PLANT MATERIAL SHALL BE FERTILIZE]:;) WITH AGRO TRANSPLANT FERTILIZER 4-2-2 PER MANUFACTURERS
#10 GAUGE SPECIFICATIONS.
IYL HOSE
OINT5 11. ALL PLANT MATERIAL SHALL CONFORM TO AAN STANDARDS FOR NURSERY STOOK LATEST EDITION. ALL PLANT
QUAL 5PACED MATERIAL FURNISHED SHALL BE HEALTHY REPRESENTATIVES, TYPICAL OF THEIR SPECIES OF VARIETY AND SHALL
HAVE A NORMAL GROWTH HABIT. THEY SHALL BE FULL, WELL BRANCHEID, WELL PROPORTIONED, AND HAVE A
VIGOROUS WELL DEVELOPED ROOT SYSTEM. ALL PLANTS SHALL BE HARDY UNDER CLIMATIC CONDITIONS SIMILAR
TO THOSE IN THE LOCALITY OF THE PROJECT. TREES, SHRUBS AND GROUNDCOVER OUANT1 TI ES, SPECIES, VARIETIES,
;)E OF MULCH SIZES AND CONDITIONS TO BE AS SHOWN ON THE PLANTING PLAN. PLANTS TO BE FREE OF DISEASE, INJURY, INSECTS,
DECAY, HARMFUL DEFECTS AND ALL WEEDS. NO SUBSTITUTIONS SHALL BE MADE WITHOUT WRITTEN APPROVAL FROM
TAKE LANDSCAPE ARCHITECT O OWNER.
=D
:5 OCCUR
EA5, PROVIDE
,H CIRCLE.
TYPICAL EVERGREEN TREE PLANTING DETAIL
NTS
SCORE ROOTBALL
3 PLACES TO 1/2" DEPTH
INSTALL 1" ABOVE
CONTAINER DEPTH
mr.,■..
PLAN VIEW OF SPACING
TOP DRESSING FERTILIZER
AS SPECIFIED
ULCH. VERIFY SAUCER
PLANTING FERTILIZER
AROUND ROOTBALL
BACKFILL W/
APPROVED TOPSOIL
TYPICAL GROUNDCOVER PLANTING DETAIL
NTS
NLMUVL IJUKLI
TWINE OFF TO[
OF ROOTBALL
2. I RR 1 GAT I ON PLAN PER RMG 4-4-0701 TO BE SUBMITTED AT A LATER DATE AS COORDINATED WITH THE CITY.
15. THE AVERAGE SPACING FOR STREET TREES SHOULD BE 40 FEET ON CENTER AND ADJUSTED TO ALLOW FOR
S I GHT LINES, UTILITIES, TRAFFIC SIGNS, L 1 GHT STANDARDS, DRIVEWAYS AND OTHER STREET APPURTENANCES.
14. TREES IN THE RIGHT OF WAY MUST BE PLANTED TO THE FOLLOWING STANDARDS: PLANT TREES IN THE CENTER OF
THE PLANTING STRIP WIDTH. & FEET FROM FIRE HYDRANTS AND UNDERGROUND UTILITIES (i e> WATER, SEWER,
ELECTRIC, GAS). 10 FEET FROM UTILITY POLES, DRIVEWAYS, AND ALLEY MARL 1 N, 25 FEET FROM STREET L 1 GHTS, 40
FEET FROM THE CORNER OF INTERSECTIONS, STOP SIGNS, AND YIELD SIGNS. AT LEAST 72 HOURS BEFORE YOU PLAN
TO DIG, YOU MUST GALL 811 TO REQUEST THAT THE LAST LOCATION OF ANY UNDERGROUND OR OVERHEAD UTILITIES
(GAS, WATER, ELECTRIC, ETC.) BE MARKED ON YOUR PLANTING AREA. KNOWING THESE LOCATIONS IN ADVANCE MAY
SAVE YOU TIME AND MONEY BY PREVENTING AN ACCIDENT.
TYPICAL SHRUB PLANTING DETAIL
NTS
3-4" MULCH
FINISH GRADE
EAK SIDES &
ITTOMS OF PLANTING
f TO ALLOW FOR
IOT PENETRATION
ECOMPACT SUBGRADE
ELOW ROOT BALL TO
ENSURE THAT ROOT
FLARE WILL NOT SETTLE
BELOW GROUND LINE
Emherre:ra
T PLANNING
:0]
10/20/2017
U3
00
ZUconOLo
~WE-+OON
W000
ZUg"�N
�aQa�
�
W
Z N
x
OUd''E-I
U cn N
Q
ZAOG�1
Z O
Coe)d0
W
W
A
W
U
a Q
STATE OF
WASHINGTON
REGISTERED
DSCAPE ARCHITECT
L90AYLE L. CRAMER
CERTIFICATE NO. 634
O
H
C.7
z
V)
m
W
�
OA
z
>
W
Oo
rl
W
O�
z
V)
Oo
Z
W/
Z
0
z
W
SHEET
L-03
RECORD DRAWING
NO CHANGES
OF 3 SHEETS