FINISH GRADE
TOPSOIL FREE OF
ROCK
SAND (OR APPRO\/ED
BACKF I LL MATERIAL)
PVC LATERAL LINE
SUBGRADE
IRRIGATION PIPE TRENCHES
SCALE: NOT TO SCALE
TO CONTROL VALVES
IRRIGATION SGH 40 MAINLINE (SIZE PER
r, 4561RA - BRONZE GATE
N STANDARD IRR16ATION
3OX. (SIZE PER PLANS)
I.D. MIN. CLEARANCE REQUIRED TO
)INT OR FITTING
MPR SHRUB SPRAY NOZZLE
(SEE IRRIGATION LEGEND)
ASPHALT, CONCRETE, MASONRY
OR CRUSHED ROCK SURFACE.
FINISH GRADE
+
POP UP SPRAY HEAD
P1—IR1-01 SCALE: NOT TO SCALE
I" OUIGK COUPLER VALVE IN 10" DIA
ROUND BOX FOR WINTERIZING SYSTEM
FLOW SENSOR
SUPERIOR MODEL 3100 (NORMALY
OPEN) MASTER VALVE IN VALVE BOX
(SIZE PER PLANS)
COPPER PIPE FROM RPBA TO MASTER
VALVE (SIZE PER PLANS)
DOH APPROVED RPBA BACK FLOW
ASSEMBLY (SIZE PER PLANS)
LO5URE: SIZED TO ALLOW FOR 6"
AT END, AND BELOW EQUIPMENT. INSTALL PER
=RS RECOMMENDATIONS.
COPPER PIPE FROM GATE VALVE TO
RPBA (SIZE PER PLANS)
KENNEDY BRONZE GATE VALVE IN
STANDARD IRRIGATION VALVE BOX.
(SIZE PER PLANS)
COPPER PIPE FROM WATER SERVICE
CONNECTION (SEE CIVIL DRAWINGS)
EXISTING WATER METER SEE CIVIL
DRAAIN65. (VERIFY STATIC
PRESSURE PRIOR TO BEGINNING
IRRIGATION WORK)
NOTES:
I. ALL COMPONENTS OF SCHEMATIC POINT OF CONNECTION
SHALL BE INSTALLED PER PROJECT SPECIFICATIONS AND
DETAILS.
2. INSTALLATION AND TESTING OF RPBA AND ANY POTABLE
WATER COMPONENTS SHALL BE COMPLETED BY A L I LENSED
PLUMBER.
3. BACKFLOW PREVENTION DEVICE INSTALLATIONS REQUIRE
INSPECTION AND CERTIFICATION BY INSPECTION SERVICE AND
SHALL MEET REQUIREMENTS OF LOCAL JURI STI CTI ON.
MANUAL DRAIN VALVE
SCALE: NOT TO SCALE
BARK MULCH FOR SHRUB
BED AREAS.
POP UP SPRAY HEAD
(SEE IRRIGATION LEGEND)
SWING JOINT ASSEMBLY
(SWING PIPE AND BARB
FITTINGS)
LATERAL LINE
+
FINISH GRADE
FUND VALVE BOX A/ LOGKIN6 LID
SPEG5.)
1,151ON5 (AS REQUIRED)
&%NUAL DRAIN VALVE W/ LONG KEY
)PERATI ON
1/4" 6ALV THREADED
U-BOLT A/ NUTS 8 WASHERS
(TYP)
BRACE PLAN VIEW
FINISH GRADE C
o }
PREFABRICATED SWING JOI
12" (MIN) VALVE
BOX W/ LOOKING
LID (SEE SPECS)
R�=1 III BRASS QUICK
COUPLER VALVE (SEE
=1 1- SPECS)
I'-6" LONG I" 50H 50
PVC
3" OF < 1 1/2" WASHED ROCK
OVER 6EOTEXTILE FABRIC
NOTE: SGH 40 PVG MAINLINE
I. USE TEFLON TAPE ON ALL THREADED FITTINGS.
QUICK COUPLER VALVE
P1—IR1-02 SCALE: NOT TO SCALE
IN LINE
SO PVC. ELL OR TEE W/ REDUCER
3GH. 50 PVC ELLS W/ PVG NIPPLES IN
WEEN - 5/4"
PVC STREET ELL 3/4" A/ 6" PVC
V HOLES DRILLED FOR DRAIN LINE
IC YARD OF GRAVEL YV/
<TILE FABRIC UNDERNEATH
_L PIPE TO DRAINAGE STRUCTURE
OR WATER COURSE
P1—IR1-06
P1—IR1-03
SPARE AIRE 3M-DBY WATERTIGHT AIRE
SPL I GE5 (TYP)
SCH 40 SCH 40 JUMBO VALVE BOX W/
PVC LOCKING LID
FINISH GRADE
1=1II SCH. 40=1I SCH 40 LATERAL LINE
`iil II II I II II II PVC
N
14
14
O MUELLER BRASS STOP GUT NOTCHES IN BOX FOR
VALVE (FOR ISOLATION PIPE AS REO'D AT EACH END
TYP)
50H 50 PVG TEE, FITTINGS UNION (2 PLACES)
ADAPTERS (AS READ)
AUTOMATIC CONTROL
MAINLINE (TYP) SOLENOID VALVE
CONTROL AIRES (BUNDLED UNDER MAINLINE ON 3" OF 1 1/2" WASHED ROOK
OPPOSITE SIDE FROM LATERALS TYP)
NOTES:
I. OUT "U" SHAPED NOTCHES IN BOTH SIDES OF VALVE BOX THAT ALLOW 2" MIN
CLEARANCE FROM TOP OF PIPE TO TOP OF GUT -OUT. USE TEFLON TAPE ON ALL
THREADED FITTIN65.
2. SEE IRR16ATION LEGEND FOR MAINLINE AND LATERAL LINE PIPE TYPES.
REMOTE CONTROL VALVE
SCALE: NOT TO SCALE
10" (MIN) VALVE BOA
W/ LOCKING LID (SEE
SPECS)
FINISH GRADE
Z SCH 40 SCH 41
PVC
I
CD
i
N
PVC SGH 80
ADAPTER
P1—IR1-04
LINE 51ZE GATE VALVE (2" AND SMALLER
HAVE A CAST OPERATING WHEEL HANDLE,
2" AND LARGER SHALL HAVE A 2"
SQUARE OPERATOR, SEE SPEC)
EXTEN51ON5 (AS REQUIRED)
SCH 40 SCH 40
PVC
MAINLINE
PVC SGH 50 ADAPTER
N
3" OF 1 1/2" WASHED ROCK
NOTE:
I. USE TEFLON TAPE ON ALL THREADED FITTINGS.
MAINLINE GATE VALVE
SCALE: NOT TO SCALE
BENCHMARK IS "SMAI"
NGS GPS CORS STATION.
ELEV = 449.6'
7 POINT OF CONNECTION SCHEMATIC
SCALE: NOT TO SCALE P1—IR1 —07 SURVEYED: SCALE:
VERTICAL: 1 1988
83/1 • O T Y O E
DESIGNED:
SEE PLANS HORIZONTAL: NAD AD 983/1991
DRAWN: R E N T O N
•
ONE INCH
LiCHECKED: AT FULL SCALE Planning/Building/Public Works Dept
IF NOT ONE INCH
WNO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY
J
L�
P1—IR1-05
Know what's below.
Call 48 hours before you dig.
O
CN
O
r
U
U
0
N
0
C)
1
L^.L
I..L
Q
STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT
YLE 1-. CRAMER
aqi;
CERTIFICATE NO. 634
CRAVER DESIGN CONSULTANTS, INC.
LANDSCAPE ARCHITECT
1909 242ND STREET SE
M
BOTHELL, WA 98021
�
425— 241— 6258
RECORD DRAWING
w
INO CHANGES R-39571 1
2
0
=
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
z
ENT PLANNING3:
A"ll, 7
Fmherrera
0
02/15/2018
W
0
W^
r/ '
SUNSET'S EDGE TOWNHOMES
DATE:
2/6/18
IRRIGATION DETAILS
FIELDBOOK:
w
PAGE:
' A
701-707 SUNSET BOULEVARD NE, RENTON, WA
DRAWING NO:
R — 2
Z
z
SUNSET'S EDGE TOWNHOMES
SHEET: 2 OF:
r/�
�/�