FINISH GRADE
W c/)
J
z TOPSOIL FREE OF
o ZZo U ROCK
N r J
Z_ Z
SAND (OR AFFRO\/ED
E3ACKF I LL MATERIAL)
0 -
CO FVC LATERAL LINE
XK\K\K�/.��/.�
IRRIGATION PIPE TRENCHES
SCALE: NOT TO SCALE
TO CONTROL VALVES
IRRIGATION SCH 40 MAINLINE (SIZE PER
r, 4561RA - BRONZE GATE
N STANDARD IRRIGATION
30X. (SIZE PER PLANS)
I.D. MIN. CLEARANCE REQUIRED TO
)INT OR FITTING
MPR SHRUB SFRA"` NOZZLE
(SEE IRRIGATION LEGEND)
ASFHALT, CONCRETE, MASONRY
OR CRUSHED ROCK SURFACE.
FINISH GRADE
+
POP UP SPRAY HEAD
P1-IR1-01 SCALE: NOT TO SCALE
I" QUICK COUPLER VALVE IN 10" DIA
ROUND BOX FOR WINTERIZING SYSTEM
FLOW SENSOR
SUPERIOR MODEL 3100 (NORMALY
OPEN) MASTER VALVE IN VALVE BOX
(SIZE PER PLANS)
COPPER PIPE FROM RPBA TO MASTER
VALVE (SIZE PER PLANS)
DOH APPROVED RPBA BACK FLOW
ASSEMBLY (SIZE PER PLANS)
LO5URF-: SIZED TO ALLOW FOR 6"
AT END, AND BELOW EQUIPMENT. INSTALL PER
=R5 RECOMMENDATIONS.
COPPER PIPE FROM GATE VALVE TO
RPBA (SIZE PER PLANS)
KENNEDY BRONZE GATE VALVE IN
STANDARD IRRIGATION VALVE BOX.
(SIZE PER PLANS)
COPPER PIPE FROM WATER SERVICE
CONNECTION (SEE CIVIL DRAWINGS)
EXISTING WATER METER SEE CIVIL
DRAWINGS. (VERIFY STATIC
PRESSURE PRIOR TO BEGINNING
IRRIGATION WORK)
NOTES:
I. ALL COMPONENTS OF SCHEMATIC, POINT OF CONNECTION
SHALL BE INSTALLED PER PROJECT SPEC I F I CATI ONS AND
DETAILS.
2. INSTALLATION AND TESTING OF RPBA AND ANY POTABLE
WATER COMPONENTS SHALL BE COMPLETED BY A LICENSED
PLUMBER.
3. BACKFLOW PREVENTION DEVICE INSTALLATIONS REQUIRE
INSPECTION AND CERTIFICATION BY INSPECTION SERVICE AND
SHALL MEET REQUIREMENTS OF LOCAL JURISTICTION.
E3ARK MULCH FOR SHRUB
BED ?AREAS.
POP OF SFR4Y HEAD
(SEE IRRI&ATION LEGEND)
SWING JOINT ASSEMBLY
(SWING PIPE AND BARB
FITTINGS)
F --- LATERAL LINE
+
FINISH GRADE
BUND VALVE BOX A/ LOCKING LID
5PEGS.)
14SIONS (AS REQUIRED)
ANUAL DRAIN VALVE A/ LONG KEY
>PERATI ON
MANUAL DRAIN VALVE
SCALE: NOT TO SCALE
91-
1/4" 6ALV THREADED -
U -BOLT A/ NUTS $ WASHERS
(TYP)
BRACE PLAN VIEW
FINISH GRADE C
PREFABRICATED SWING JOINT
12" (MIN) VALVE
BOX A/ LOGKIN6
LID (SEE SPECS)
1 BRASS OUIGK
COUPLER VALVE (SEE
- -SPECS)
I'-6" LONG I" SCH 80
PVC,
3" OF < 1 1/2" WASHED ROCK
OVER 6EOTEXTILE FABRIC,
NOTE: SCH 40 PVC MAINLINE
I. USE TEFLON TAPE ON ALL THREADED FITTINGS.
QUICK COUPLER VALVE
P1-IR1-02 SCALE: NOT TO SCALE
IN LINE
80 PVC, ELL OR TEE A/ REDUCER
3GH. 80 PVC ELLS A/ PVC NIPPLES IN
WEEN - 3/4"
PVC, STREET ELL 3/4" A/ 6" PVC
V HOLES DRILLED FOR DRAIN LINE
IG YARD OF GRAVEL A/
<TILE FABRIC UNDERNEATH
_L PIPE TO DRAINAGE STRUCTURE
OR WATER COURSE
P1-IR1-06
P1-IR1-03
SPARE AIRE
SCH 40 SCH 40
PVC
FINISH GRADE
3M-DBY WATERTIGHT AIRE
SPLICES (TYP)
JUMBO VALVE BOX A/
LOCKING LID
SCH
40=11 SCH 40 LATERAL LINE
PVC _
c -To
REMOTE CONTROL VALVE
SCALE: NOT TO SCALE
10" (MIN) VALVE BOX -
A/ LOGKIN6 LID (SEE
SPECS)
FINISH GRADE
z SCH 40 SCH 40-11
PVC 11
O
cV
PVC, SGH 50
ADAPTER
P1-IR1-04
LINE SIZE GATE VALVE (2" AND SMALLER
HAVE A CAST OPERATING WHEEL HANDLE,
2" AND LARGER SHALL HAVE A 2"
SQUARE OPERATOR, SEE SPEC)
EXTENSIONS (AS REQUIRED)
SCH 40 SCH 40
PVC
MAINLINE
PVC, SCH 50 ADAPTER
N
T 3" OF 1 1/2" WASHED ROCK
NOTE:
I. USE TEFLON TAPE ON ALL THREADED FITTINGS.
MAI N LI N E GATE VALVE
SCALE: NOT TO SCALE
BENCHMARK IS "SMAI"
NGS GPS CORS STATION.
ELEV = 449.6'
7 POINT OF CONNECTION SCHEMATIC
SCALE: NOT TO SCALE P1-IR1-07SURVEYED: SCALE:
VERTICAL: NAVD 1988 •
SEE PLANS HORIZONTAL: NAD 1983/1991 C T Y 0
DESIGNED:
DRAWN:,Ri RENTON
ONE INCH 1%30F
CHECKED: AT FULL SCALE Planning/Building/Public Works Dept
w
g IF NOT ONE INCH
wN 0. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY
J
L�
P1-IR1-05
Know what's below.
Call 48 hours before you dig.
co
O MUELLER BRASS STOP
VALVE (FOR ISOLATION
GUT NOTCHES IN BOX FOR
PIPE AS REO'D AT EACH END
TYP)
CD
SCH 50 PVC TEE, FITTINGS 4
UNION (2 PLACES)
ADAPTERS (AS REOD)
C)
YLE L. CRAMER
0qi;
AUTOMATIC CONTROL
— MAINLINE (TYP)
SOLENOID VALVE
CONTROL WIRES (BUNDLED UNDER MAINLINE ON
3" OF I/2" WASHED ROCK
OPPOSITE SIDE FROM LATERALS TYP)
NOTES:
LO
cy)
1. GUT "U" SHAPED NOTCHES IN BOTH SIDES OF VALVE BOX THAT ALLOW 2" MIN
CLEARANCE FROM TOP OF PIPE TO TOP OF GUT -OUT.
USE TEFLON TAPE ON ALL
THREADED FITTINGS.
2. SEE IRRIGATION LEGEND FOR MAINLINE AND LATERAL LINE PIPE TYPES.
REMOTE CONTROL VALVE
SCALE: NOT TO SCALE
10" (MIN) VALVE BOX -
A/ LOGKIN6 LID (SEE
SPECS)
FINISH GRADE
z SCH 40 SCH 40-11
PVC 11
O
cV
PVC, SGH 50
ADAPTER
P1-IR1-04
LINE SIZE GATE VALVE (2" AND SMALLER
HAVE A CAST OPERATING WHEEL HANDLE,
2" AND LARGER SHALL HAVE A 2"
SQUARE OPERATOR, SEE SPEC)
EXTENSIONS (AS REQUIRED)
SCH 40 SCH 40
PVC
MAINLINE
PVC, SCH 50 ADAPTER
N
T 3" OF 1 1/2" WASHED ROCK
NOTE:
I. USE TEFLON TAPE ON ALL THREADED FITTINGS.
MAI N LI N E GATE VALVE
SCALE: NOT TO SCALE
BENCHMARK IS "SMAI"
NGS GPS CORS STATION.
ELEV = 449.6'
7 POINT OF CONNECTION SCHEMATIC
SCALE: NOT TO SCALE P1-IR1-07SURVEYED: SCALE:
VERTICAL: NAVD 1988 •
SEE PLANS HORIZONTAL: NAD 1983/1991 C T Y 0
DESIGNED:
DRAWN:,Ri RENTON
ONE INCH 1%30F
CHECKED: AT FULL SCALE Planning/Building/Public Works Dept
w
g IF NOT ONE INCH
wN 0. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY
J
L�
P1-IR1-05
Know what's below.
Call 48 hours before you dig.
co
STATE OF
LO
WASHINGTON
CD
REGISTERED
LANDSCAPE ARCHITECT
C)
YLE L. CRAMER
0qi;
O
CERTIFICATE N0. 634
CRAMER DESIGN CONSULTANTS, INC.
r
U
U
00
0
0
1
Q0
1
Q
Z)
J
N
O
0
1
r
Q
STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT
YLE L. CRAMER
0qi;
CERTIFICATE N0. 634
CRAMER DESIGN CONSULTANTS, INC.
LANDSCAPE ARCHITECT
1909 242ND STREET SE
LO
cy)
BOTHELL, WA 98021
�
425-241-6258
I..LI
W-395701 S-395701 R-395717
O
=
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
z
ENT PLANNING
Fmherrera
Q
02/15/2018,Rj
W
0
W
SUNSET'S EDGE TOWNHOMES
DATE:
2/6/18
IRRIGATION DETAILS
PAGE:OOK:
PAGE:
c/)
DRAWING N0:
R-2
701-707 SUNSET BOULEVARD NE, RENTON, WA
z
SUNSET'S EDGE TOWNHOMES
�^
�/J
SHEET: 2 OF:
DCI PROJECT NO. 15375