Loading...
HomeMy WebLinkAboutConcrete Field Report_2025-09-08-Lindbergh High School Field Improvements-25B121-01_000001Inspection Information: Inspection Date:09/08/2025 Time Onsite:09:30 Weather Conditions:Cloudy, 64 deg Inspection Performed: Concrete Subcontractor:Continuous or Periodic:Continuous Inspection Sheet(s):Location / Area: Dugout curbwalls/retaining walls (see below) Details:3 and 5/F240 Level / Elevation:Upper and Lower fields Approved Plans Dated: Report Profile: Any Deficiencies Noted:Yes No Deficiencies Cleared:Yes No RFI:Yes No Show Up:Yes No Retest / Re­inspection:Yes No Standby:Yes No Remarks: 1) Locations: Upper Softball Field­ Western dugout mono­poured retaining wall and thickened edge slab, South dugout curbwall; Lower Baseball Field­East dugout retaining and curb walls, South dugout curbwalls 2) Reinforcing:  MTC verified the reinforcing steel at the locations noted above.  Retaining walls had #4 bar at 9" on­center each way and each face.  Curb/stemwalls had (2) continuous #4 bars.  The slab­on­grade was reinforced with wire mesh.   All reinforcing was found to be secure and was of correct grade, size, location, spacing, lap and clearance, and was in­compliance with approved plans and specs. 3) Concrete: MTC witnessed the placement of 30 yards of Miles concrete mix #1250AF, 4500 psi minimum required strength.  The concrete was placed by truck chute and mechanically vibrated for consolidation.  One set of five 4x8 cylinders was cast for compressive strength testing.  To the best of MTC inspector's knowledge, the above­described work was performed in general accordance with project specifications and approved plans. Work in progress. Additional inspection needed. Images: ✔ ✔✔ ✔✔ ✔ Concrete Field Report RCCON­000001­00Report #: Burlington 777 Chrysler Drive Burlington, WA 98233 Phone: (360) 755­1990 Client: Renton School District No. 403 300 SW 7th St Renton, WA 98057 Project: 25B121­01 (Bldg Permit: B25002218) Lindbergh High School Field Improvements 16426 128th Avenue Southeast Renton, WA 98059 As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Page 1 of 4Page 1 of 3 Inspection Information:Inspection Date:09/08/2025 Time Onsite:09:30 Weather Conditions:Cloudy, 64 degInspection Performed: ConcreteSubcontractor:Continuous or Periodic:Continuous InspectionSheet(s):Location / Area:Dugout curbwalls/retaining walls (see below)Details:3 and 5/F240 Level / Elevation:Upper and Lower fieldsApproved Plans Dated:Report Profile:Any Deficiencies Noted:Yes No Deficiencies Cleared:Yes NoRFI:Yes No Show Up:Yes NoRetest / Re­inspection:Yes No Standby:Yes NoRemarks:1) Locations: Upper Softball Field­ Western dugout mono­poured retaining wall and thickened edge slab, South dugout curbwall;Lower Baseball Field­East dugout retaining and curb walls, South dugout curbwalls2) Reinforcing:  MTC verified the reinforcing steel at the locations noted above.  Retaining walls had #4 bar at 9" on­center each wayand each face.  Curb/stemwalls had (2) continuous #4 bars.  The slab­on­grade was reinforced with wire mesh.   All reinforcingwas found to be secure and was of correct grade, size, location, spacing, lap and clearance, and was in­compliance with approvedplans and specs.3) Concrete: MTC witnessed the placement of 30 yards of Miles concrete mix #1250AF, 4500 psi minimum required strength.  The concrete was placed by truck chute and mechanically vibrated for consolidation.  One set of five 4x8 cylinders was cast for compressive strength testing.  To the best of MTC inspector's knowledge, the above­described work was performed in general accordance with project specifications and approved plans. Work in progress. Additional inspection needed. Images: ✔✔✔✔✔ ✔ Concrete Field Report RCCON­000001­00Report #: Burlington 777 Chrysler Drive Burlington, WA 98233 Phone: (360) 755­1990 Client: Renton School District No. 403 300 SW 7th St Renton, WA 98057 Project: 25B121­01 (Bldg Permit: B25002218) Lindbergh High School Field Improvements 16426 128th Avenue Southeast Renton, WA 98059 As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Page 2 of 4Page 2 of 3 Inspection Information:Inspection Date:09/08/2025 Time Onsite:09:30 Weather Conditions:Cloudy, 64 degInspection Performed: ConcreteSubcontractor:Continuous or Periodic:Continuous InspectionSheet(s):Location / Area:Dugout curbwalls/retaining walls (see below)Details:3 and 5/F240 Level / Elevation:Upper and Lower fieldsApproved Plans Dated:Report Profile:Any Deficiencies Noted:Yes No Deficiencies Cleared:Yes NoRFI:Yes No Show Up:Yes NoRetest / Re­inspection:Yes No Standby:Yes NoRemarks:1) Locations: Upper Softball Field­ Western dugout mono­poured retaining wall and thickened edge slab, South dugout curbwall;Lower Baseball Field­East dugout retaining and curb walls, South dugout curbwalls2) Reinforcing:  MTC verified the reinforcing steel at the locations noted above.  Retaining walls had #4 bar at 9" on­center each wayand each face.  Curb/stemwalls had (2) continuous #4 bars.  The slab­on­grade was reinforced with wire mesh.   All reinforcingwas found to be secure and was of correct grade, size, location, spacing, lap and clearance, and was in­compliance with approvedplans and specs.3) Concrete: MTC witnessed the placement of 30 yards of Miles concrete mix #1250AF, 4500 psi minimum required strength.  Theconcrete was placed by truck chute and mechanically vibrated for consolidation.  One set of five 4x8 cylinders was cast forcompressive strength testing. To the best of MTC inspector's knowledge, the above­described work was performed in general accordance with projectspecifications and approved plans.Work in progress. Additional inspection needed.Images: Reported By:Ross Jorgensen Reviewed By:Kevin Walters ✔✔✔✔✔✔ Concrete Field Report RCCON­000001­00Report #: Burlington 777 Chrysler Drive Burlington, WA 98233 Phone: (360) 755­1990 Client: Renton School District No. 403 300 SW 7th St Renton, WA 98057 Project: 25B121­01 (Bldg Permit: B25002218) Lindbergh High School Field Improvements 16426 128th Avenue Southeast Renton, WA 98059 As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Page 3 of 4Page 3 of 3