Loading...
HomeMy WebLinkAboutWTR2703149 GENERAL NOTES FRANCHISE UTILITIES �_ KEY MAP m 1 . THE EXISTING UTILITIES SHOWN ON THE DRAWINGS ARE APPROXIMATE DRAWING LIST DRAWING LIST 6o ONLY, AND ARE BASED ON AVAILABLE UTILITY INFORMATION PROVIDED SCALE BY THE OWNER, ON FIELD SURVEY OF VISIBLE FEATURES, AND ON A W 300 0 150 300 600 FEW SELECTED POTHOLE SITES. THE OWNER AND THE ENGINEER DO DWG TITLE DWG TITLE NOT ASSUME RESPONSIBILITY FOR THE ACCURACY OR COMPLETENESS NO. NO. ( FEET ) OF THIS UTILITY INFORMATION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS 86 U00 KEY MAP, GENERAL NOTES, ABBREVIATIONS, 1 OF 1 PSE POWER LINE ROUTING N TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48-HOURS LOCATORS, 1 -800-424-5555. AND SHEET LIST 1 OF 11 30 UG FEED AND BACKBONE J�O 87 U01 LOGAN AVE. N. STA. 143+00 TO STA. 147+75 2 OF 11 30 UG FEED AND BACKBONE 2. IN AND ADJACENT TO THE PROJECT RIGHT-OF-WAY BOEING UTILITIES /y CITY OF RENTON UTILITIES, AND FRANCHISE UTILITIES, ARE MARKED "TO 88 UO2 LOGAN AVE. N. STA. 147+75 TO STA. 42+00 3 OF 11 30 UG FEED AND BACKBONE REMAIN"; OTHER UTILITIES INDICATED IN THE BASE MAPPING ARE 89 UO3 LOGAN AVE. N. STA. 42+00 TO STA. 46+50 4 OF 11 30 UG FEED AND BACKBONE ABANDONED, TO THE BEST OF THE ENGINEER'S KNOWLEDGE. T OF 11 30 UG FEED AND BACKBONE �• 90 U04 LOGAN AVE. N. STA. 46+50 TO STA. 51 +00 8 3. THE CONTRACTOR SHALL POTHOLE ALL EXISTING UTILITY LINES TO 91 U05 LOGAN AVE. N. STA. 51 +00 TO STA. 55+50 REMAIN (FOR WHICH VERTICAL INFORMATION IS NOT SHOWN) TO 92 U06 LOGAN AVE. N. STA 55+50 TO STA. 60+00 1 OF 1 PSE GAS LINE ROUTING DETERMINE THEIR EXACT HORIZONTAL AND VERTICAL LOCATIONS IN A 93 U07 LOGAN AVE. N. STA. 60+00 TO STA. 64+50 1 OF 2 6", 4", AND 2" COMML MAIN SUFFICIENT TIME IN ADVANCE OF THE PIPELAYING OPERATION TO ALLOW ` ADJUSTMENTS TO BE MADE AS NECESSARY TO AVOID CONFLICTS. THIS 94 U08 LOGAN AVE. N. STA. 64+50 TO STA. 69+00 2 OF 2 6", 4", AND 2" COMML MAIN WORK SHALL BE CONSIDERED INCIDENTAL TO OTHER BID ITEMS. 95 U09 LOGAN AVE. N. STA. 69+00 TO STA. 72+50 N i v�8 4. CONTRACTOR SHALL COORDINATE WITH KING COUNTY METRO 96 U 10 LOGAN AVE. N. STA. 72+50 TO STA. 76+00 E1 .0 QWEST TELECOM FACILITIES v�7 WHENWORKING NEAR, OR CONNECTING TO, METRO'S 96-INCH SEWER. 97 U 11 N. 8TH ST. STA. 61 +00 TO STA. 64+25 V15 U16 SEE SPECIFIC METRO NOTES BELOW. E1 .1 QWEST TELECOM FACILITIES 98 U 12 N. 8TH ST. STA. 64+25 TO STA. 69+00 E1 .2 QWEST TELECOM FACILITIES -- 5. REFER TO SPECIAL PROVISIONS SECTION 1 -07.17 FOR ADDITIONAL 0 INFORMATION AND REQUIREMENTS RELATED TO EXISTING UTILITIES. 99 U13 N. 8TH ST. STA. 69+00 TO STA. 71 +50 E1 .3 QWEST TELECOM FACILITIES 100 U14 N. 8TH ST. STA. 73+25 TO STA. 78+00 E1 .4 QWEST TELECOM FACILITIES N. 10TH ST. 101 U 15 N. 10TH ST. STA. 51 +00 TO STA. 55+00 CN z METRO SEWER NOTES E1 .5 QWEST TELECOM FACILITIES I I 102 U16 N. 10TH ST. STA. 55+00 TO STA. 59+00 E1 .6 QWEST TELECOM FACILITIES 1 . MR. ERIC DAVISON OF KING COUNTY WASTEWATER TREATMENT DIVISION 103 U17 N. 10TH ST. STA. 59+00 TO STA. 63+50 E1 .7 QWEST TELECOM FACILITIES 4 I I (206/684- 1707) SHALL BE NOTIFIED AT LEAST TWO (2) WORKING 104 U 18 N. 10TH ST. STA. 63+50 TO STA. 66+72.36 N DAYS PRIOR TO CONSTRUCTION IN THE VICINITY OF KING COUNTY'S 96" 105 U 19 PARK AVE. N. STA. 17+00 TO STA. 24+75 1 OF 1 CEV VAULT METRO SEWER. - 106 U20 PARK AVE. N. STA. 24+75 TO STA. 29+50 d- U11 U12 U13 U14 2. PLANS FOR DEWATERING ADJACENT TO KING COUNTY FACILITIES SHALL BE SUBMITTED TO MR. ERIC DAVISON FOR KING COUNTY REVIEW AND 107 U21 PARK AVE. N. STA. 29+50 TO STA. 34+25 1 OF 1 COMCAST TELECOM ROUTING APPROVAL AT LEAST FIVE DAYS PRIOR TO CONSTRUCTION. 108 U22 PARK AVE. N. STA. 34+25 TO STA. 39+00 N. 8TH ST. , , 3. MANHOLES R02-5 AND R02-7 SHALL BE EXCAVATED COMPLETELY 109 U23 PARK AVE. N. STA. 39+00 TO STA. 43+50 AROUND OR STRUCTURALLY SUPPORTED DURING CONSTRUCTION TO 110 U24 PARK AVE. N. STA. 43+50 TO STA. 46+69.44 I AVOID UNBALANCED SOILS LOADING. N 1 1 1 U25 N. 6TH ST. STA. 27+75 TO STA. 31 +00 z ' ' 4. DURING CONSTRUCTION, NO DEBRIS SHALL BE ALLOWED TO ENTER KING 112 U26 WATER CONNECTION DETAILS ' '-'-' I COUNTY S METRO SEWER. Q 113 U27 MISCELLANEOUS WATER DETAILS r Y 5. THE CONNECTIONS TO KING COUNTY'S MANHOLES SHALL BE PLUGGED 114 U28 METRO SEWER CONNECTION DETAILS m z ' a I AND NOT BE PUT INTO SERVICE UNTIL THE TRIBUTARY SYSTEM HAS z y �' I 1 15 U29 MISCELLANEOUS DETAILS BEEN CLEANED, INSPECTED, TESTED, AND APPROVED BY THE CITY OF r- o RENTON. 116 U30 METER VAULT DETAILS x � I t 117 U31 METER VAULT ELECTRICAL � o � N •- ' ABBREVIATIONS 118 U49 JOINT UTILITY PLAN 119 U50 JOINT UTILITY DETAILS °y U25 :D C/L CENTERLINE NW NORTHWEST 120 U51 JOINT TRENCH DETAILS W r N. 6TH ST. CB CATCH BASIN P PARK, POWER 121 U52 JOINT TRENCH DETAILS c N. 6TH ® CMP CORRUGATED METAL PIPE PIV POST INDICATOR VALVE 122 U52A JOINT TRENCH DETAILS c m CONC CONCRETE R/W RIGHT OF WAY 123 U53 SETTLEMENT MONITORS AND WELL ABANDONMENT I DI DUCTILE IRON RT RIGHT I ; DIA DIAMETER S SLOPE, SOUTH, SEWER I DWG DRAWING SD STORM DRAIN E EAST SDMH STORM DRAIN MANHOLE I • ELEV LEVATION SE SOUTHEAST r EX EXISTING SS SANITARY SEWER ' FM FORCE MAIN SSFM SANITARY SEWER FORCE MAIN G GAS SSMH SANITARY SEWER MANHOLE HPW HIGH PRESSURE WATER STA STATION W= 314901 IE INVERT ELEVATION STE STEAM C . A IW INDUSTRIAL WASTE SW SOUTHWEST ��°� WA L LOGAN T TELEPHONE RECORD DRA WINGS f PREPARED BY WHPACIFIC, FEBRUARY 2010, BASED � LF LINEAL FEET TCE TEMPORARY CONSTRUCTION ON CONTRACTOR RECORDS. Ago �� 0035524 LT LEFT EASEMENT ��ss,ST N NORTH W WATER, WEST AL EXPIRES 06/06/07 NE NORTHEAST WV WET VAULT RECORD DRAWING WR 1 1 M V SURVEYED: SCALE: HORIZONTAL VERTICAL N D;91988 , ;� ��. BHC Consultants, LLC CSR AS SHOWN •• CITY OF CITY OF RENTON 4/1 /06 1yHPd(1f11( ■ 720 Third Avenue, Suite 1200 DESIGNED: � Seattle, Washington 98104-1820 DRAWN: � R E N TO N SOUTH LAKE WASH INGTON �°°"� " 12100NE 195th St,Ste 300 ■ Tel: (206) 505-3400 CAD ONE INCH DATUM ROADWAY IMPROVEMENTS DRAWING W. Bothell,WA 98011 CONSULTANTS Fax: (206) 505-3406 1 1 1 CHECKED: AT FULL SCALE Planning/Building/Public Works Dept. UTILITY U00 425-951.4800 Fax 425-951-4808 LCA IF NOT ONE INCH www.whpacific.com Formerfya Division of Berryman&Henigar NO. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY KEY MAP, GENERAL NOTES, ABBREVIATIONS AND SHEET LIST SHEET: OF:LCASs 205