HomeMy WebLinkAboutWTR2703149_24 � y ' s 1 1 11111 STA 46+59.87,
C) 0 �� o� i ° no,-, 1�I N_ 111I 47.0' LT
efi ���,�' �"TCE /� D �� m I III 11 MII REMOVE EX SSMH SCALE
r y` / �° ° m a ' a I I I � 20 0 10 20 40
M o �� �' \� I I III +o 1 � 111 AND REPLACE WITH
�VM pN°O �o w�'"� o= I III o ,�L 1 III SSMH #P-3, 48"
z ji; w� I I// o�� 1 � ( FEET
JOINT TRENCH 1�j►� ' : R/W VE I n'``'
SEE SHEETS oa // I ; IUI STA ,46+75.14,
W M - \ �'` I ��/ \ �JN i 49.3 LT
I— N U44 U48, TYP f \Z //� I 1 111 V CONNECT TO
/ °m + ii I �` EX METRO SSMH E] CONSTRUCTION NOTES
b i 1 111
12'V# R02-7
1 . PROTECT EXISTING BOEING UTILITY TO REMAIN.
/ �.. SEE DETAIL 1 ,
o s �`' _ _ o �/ I w o / �`� SS //A 1 SHEET_ 28
W / / 1\Z SD FqL \ o o / I om 1 �l 2. DEMOLISH EXISTING SSMH AND REPLACE WITH NEW
a ti �`' �� __� , I ,� z '� ► SSMH.
o, 1 , o 1 ��� STA 46+26.09,
_�, a Z b 1 4 1 ,
�, a 0 \ ti ti tiw. 'o� cn l ,_U\ /// 1 y 13.47 LT ,
Lj ^a� _�� w �� 1 111 ►� 3. STA 43+51 .41 , 38.75 RT
W N ° a 1 SSMH #P-2 48
oti ,, \� N� 1 s FIRE HYDRANT ASSEMBLY
(/) � / �J°�� �� �a `� °� \ o 1 III 1 IAA SEE RENTON STD PLAN B102
o 00 12 SS o`'�'�'°�o N 1 III 1 ' EX 96 -
METRO
�Q o 0 1 o �y r 1 III 1 1' 4. WATER CROSSING UNDER STORM DRAIN AND JOINT
O v` a� y I o ��� ,aa I i 111 SEWER
�`bo �ti ' (�� 11\ 1 TRENCH WITH 12" CLEARANCE. SEE DETAIL 2,
�. � 4+Og 45+00 - °°°ti ��IF �� 46+0 I - 1 x \\\ 47+00 - DWG U27.
00
43+51 .41 38.75' ; `\� c� T `�'a 1
A'Al
FIRE HYDRANT AS NB
Q 9' FROM FACE
\\\ - o
/ „ OF CURB o��� ^O Z w �\� I ' �, \\ 1 1 �,
12 12 w u 12 w y ,�4 __ �o \� ► 0 GENERAL NOTES:
° o o N A 1 ' � o y 1 . FOR STORM DRAIN LOCATIONS, SEE DWGS
Z 0 yM.
/o O mZ O + m prn ��
�� + SD00-SD25.
�. 1, D O a�
CD c
2. FOR VERTICAL AND HORIZONTAL PIPE JOINT
\�� DEFLECTIONS IN WATER LINE, DEFLECT PIPE JOINTS
R W ` ��w`"'�a I 7 RT \� ' NO MORE THAN
OF MANUFACTURER'S
/ ` ` STA 45+53.80 67 9 \ 1 RECOMMENDEDMAXIMUM.
FIRE HYDRANT ASSEMBLY
N � SEE RENT�ON STD PLAN B102 \ ; 3. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE
1 -12 x12 VERTICAL CROSS, MJ x FL I 11, 1 1 ` WRAPPED WITH BLACK, TUBE-FORM POLYETHYLENE
PER DETAIL 3 SHEET U26 I' PER ANSI/AWWA C105.
LOGAN AVE N �Q o \ 1 -12 CAP, MJ , 1
STA 68+40.76, 45.24' RT �`�� coo\ �. �` / 1 -THRUST BLOCK 1 rnl 11 WATER ELEVATIONS APPROXIMATE EXCEPT WHERE
- �c o��° `o� + NOTED.
1 12 CROSS, FL x FL o =oaa o o ,;_ 11
4-12" GATE VALVES, FL x MJ ti o ' o ° �° I R/W o l 111
=
PARK AVE N STA. 44+88.02
40 LOGAN AVE , N STA. 68+ 14.92 NtS.H€.
ELEV=29.08; z _ z
i GRADE @ o z I
CONSTRUCTION w C j �I� O
C/L Q W bj cn -I w 041 a_ ` � > cam)
> -
' oo I � `� II
F- N z C«) 00 W W I �' Z � c0 x z I
z 000 - _ o Ln 000 EXISTING >►- a - + o rn = 0 0- U) I w o +
- � � °' l`— cnN � °' GROUND @ * (n _ x I
z w - w — a_ a
o . w - O w - N 0 _ „ � 0 X LEGEND:
_ � w o � Nw N� � w CONSTRUCTION o X Nwm X X V X glw oQ x �
0
w X X m C/L m ''' w w w W V) JOINT TRENCH SEE SHEETS U49-U52A "� 1
N 0 �' '1' _ _ __ - -_ _ _. FOR PLAN AND SECTIONS N z In
N
�---mil-- _ o 1
---�-
203 LF _ I 1 d w
JCL '2 W
W — ---- ------ 2 pl _ > o
�
W I
W I 2
i I
12 LF — 12" PVC RECORD DRA WINGS
I PREPARED BY WHPACIFIC,
to 15 LF - 120 PVC SS 12 48 PVC SS S=O.O20 FT/FT FEBRUARY 2010, BASED
I ON CONTRACTOR RECORDS.
S=0.004 FT/FT S=0.004
zFT/FT --- r
�
-- }$--
z EX METRO SSMH_ R02-7
Z N 04 CHANNEL 9.5t
.--
I`n ! IE 13.17 - 12 SE
FWA
() o N , w w hlt PLUG EX 8" SS W/ MIN
~ N ' ( r� 12" LONG CONC PLUG
c i II N RECONNECT EX 12" 1 IE 12.Of;
w w W C O N C SS, IE 16.2 f W �� ,� 0035524 w�
Z Z ? I sS/OtVAL �yG
't� ICI STB� t
O!� `� �t N �jN N O + O �'O �l� O � O
10) D t 00 1 . 00 00 .1 t\ r O I
CO Y I CD .Y 061 c6 00 00 00 00 I 00 O EXPIRES 06/06l07
N ) N N ) N (V ) �` N N N N N N N NIN N (-,1!
• 0 44+0 44+50 45+00 45+50 46+00 46+50 47+00
Al N H .1 1 V SURVEYED SCALE:u rr�� ,E�� NAVD 19Be ��:
IWH a--c-I- c n- ■ BHC Consultants, LLC DESIGNED sR H' 1"=20' HORIZONTAL: NAD lW3/1991 _ CITY OF
CITY OF RENTON 4/17/os
720 Third Avenue, suite 1200 DN V' 1"-5' •.0 R E N TO N SOUTH LAKE WASHINGTON
Seattle, Washington 98104-1820 DRAWN: PLS — ROADWAY IMPROVEMENTS DRAWING NO:
"� 12100 NE 195th St,Ste 300 ■ Tel: (206) 505-3400 ONE INCH DATU M
Bothell,WA 98011 CONSULTANTS Fax: (206) 505-3406 CHECKEDL� AT FULL SCALE Planning/Building/Public Works Dept. UTILITY PLAN AND PROFILE U24
425-951-4800 Fax 425-951-4808
IF NOT ONE INCH
www.whpacific.com Formerlya Division of Berryman&Henigar NO. REVISION BY DATE APPR -IROVED: SCALE ACCORDINGLY PARK AVE. N. STA. 43+50 TO STA. 46+69.44 SHEET:
LCAf!