HomeMy WebLinkAboutWTR2703149_28 0) RIM ELEV, SEE TABLEqt T z CM NOTE: > > NOTE : SEE METRO SEWER 6 1 . PLAIN END PIPE SHALL BE - --� USED FOR PENETRATION OF w MANHOLE WALLS. ► NOTES " ON DWG UOO FOR I MANHOLE ELEVATION DATA CONDITIONS THAT APPLY METRO RIM TO THIS WORK MH NO. STATION ELEV IE IN DIRECTION 96 IE 1 BELOW 10.40 E R02-3 LOGAN 48+13f — 10.65 W 7.65 EX 4'-0"" MH {' { I � R02-5 LOGAN 56+80t 31 .02 f 11 .99 E 11 .85 W 8.85 R02-7 PARK 46+60t 29.07 f 13.17 SE 9.50 9 i I I EX. 96" SEWER I ��- ' D `� c y 4 V' Q a D EX PIPE AND ENCASEMENT CORE DRILLED HOLE a I D a SHALL BE CORE DRILLED (SIZE TO MATCH p D FOR KOR-N-SEAL BOOT KOR-N-SEAL BOOT) WITH STAINLESS STEEL I WEDGES (DIST BY HANSEN __ ---- -- - EX PIPE AND ENCASEMENT ' ! ' PIPE PRODUCTS) '` b SHALL BE CORE DRLLED I FOR KOR-N-SEAL BOOT CUT THROUGH EX 1 " WITH STAINLESS STEEL ( STEEL PLATE USED FOR WEDGES (DIST BY HANSEN a SHORING MIN 3" BEYOND I PIPE PRODUCTS) PIPE. BACKFILL CDF MIN 3 ti D EITHER SIDE OF NEW 1' AND TO 1 ' CUT THROUGH EX STEEL NEW SEWER CROWN TO MATCH SEWER C/L, NEW SEWER CROWN TO MATCH SHORING/FORMING AS V' SPRING LINE OF EX METRO ABOVE NEW SEWER SPRING LINE OF EX METRO f SEWER PIPE NOTED ON DETAIL 2/ , OR WHERE EX � � � � SEWER PIPE, OR WHERE EX PIPE CONN EXISTS, REMOVE EX �� FLEXIBLE JOINT, PIPE CONN EXISTS, REMOVE EX Q PIPE AND CENTER NEW CORE `� PUSH-ON PIPE AND CENTER NEW CORE z FLEXIBLE JOINT, DRILL HOLE ON EX HOLE DRILL HOLE ON EX HOLE cn % m PUSH-ONlb 12" OR 15" PVC ° I SEWER AS NOTED 12 PVC SEWER ; ON PLANS a_ _ _ _ _ _ ��� _ _ 1 i D II I � � � 1 � I E Nz � I II I o 1 12' IE, D Q ? � SEE TABLE i I i ; •� f 2' TO 3' 2 TO 3 CONNECTION AT N 8TH ST DETAIL co A 2 NOT TO SCALE U1 1 a ° + C . RECORD DRA WINGS °F 96" IE EX C O N CW 314929 PREPARED BY WHPACIFIC, C/L SEE TABLE ENCASEMENT FEBRUARY 2010, BASED a AT MH ON CONTRACTOR RECORDS. 0035524 4� STE¢ti METRO SEWER MANHOLE CONNECTION DETAIL SSIALG 1 EXPIRES 06/08/07 NOT TO SCALE U06, U24 1 RECORD RA I HQS 3.12.10M V SURVEIED: SCALE: VERTICAL NAVD 1988 DAM ■ BHC Consultants, LLC csR AS SHOWN HORIZONTAL: NAD 1963/1991 A6 CITY OF RENTON 4/17/06 720 Third Avenue, suite 1200 DESIGNELCA �- CITY OF SOUTH LAKE WASHINGTON � RENTON PAGE: : IWHPTCfic Seattle, Washington 98104-1820 DRAWN: CAD ROADWAY IMPROVEMENTS lei Tel: 206 505-3400 014E INCH °R'`"""G N0' 12100 NE 195th St,Ste 300 ( ) DATUM Bothell,WA 98011 CONSULTANTS Fax: (206) 505-3406 CHECKED: AT FUII SCALE Planning/Building/Public Works Dept. METRO SEWER CONNECTION DETAILS U28 425-951-4800 Fax 425-951-4808 IF NOT ONE INCH www.whpacific.com Formerly a Division of Berryman&Henigar NO. REVISION BY DATE AP P R ^PPROVE: 14 SCALE ACCORDINGLY SHEET. 1 OF: 205 gyp , 3141 c�9