Loading...
HomeMy WebLinkAboutWTR2703149_30 I a GALV STEEL PIPE V-6" SQ SUMP STANCHION SADDLE co AND PUMP METER VAULT O HATCH SEE SECTION B ---4 ABOVE 14 B COMPONENTS 0 � GALV STEEL SCH 40 O ADJUSTABLE PIPE METER VAULT 4'-2"x6'-6" MIN INTERIOR STANCHION, FIG 63, d 4 d DIMENSION, 2-1 /2" DIA UTILITY VAULT 577—LA, OR EQUAL 1 /2" SST BOLTS WITH I ACCESS HATCH SINGLE—LEAF 30"x46" NUTS AND WASHERS, HINGE � i ' ` O GALVANIZED STEEL OR ALUMINUM COVER TYP OF 4 i SIDE H-10 RATED GALV STEEL BASE ` 6" PLUG VALVE, MJxMJ PLATE 3/8"x8"x8" 1 " GROUT AS REQ'D —♦"' ' ' i _ _ 0 6" MAGNETIC FLOWMETER, FLxFL L4 EMBEDMENT DEPTH IN 0 6PNA. U h/\fd� V\/� " FLANGED COUPLING ADAPTER ACCORDANCE WITH C-100 EPDXY TO FLOOR I � MANUFACTURER'S j v 60 6" DI 45- BEND, FLxFL RECOMMENDATIONS 70 6"x6"x6" DI WYE, FLxFL, WITH BLIND FLANGE 00o, 7 NOTES: 1 —6 B 0 6" DI SPOOL, FLxPE 1 . TO ENSURE PROPER SUPPORT AND STABILITY, AFTER 5 0 FINAL HEIGHT ADJUSTMENT IS ATTAINED, APPLY TACK CLR 90 6"x 12" LONG DI SPOOL, FLxFL WELDS TO BOTH SUPPORT CUPS AND EXTENSION PIPE. USE E70XX ELECTRODE FOR WELDS. 10 6" DI SPOOL FLxPE METER READOUT BASE 2. HOT DIP GALVANIZE ALL PARTS AFTER FABRICATION. SEE DETAIL 2, SHEET U31 - � 1 PIPE SUPPORT, SEE DETAIL 2/— � 0 3. TOUCH—UP GALVANIZE BURNS AN T D CUTS. 12 MANHOLE STEPS, 5 EACH POLYPROPYLENE ENCAPSULATED - 1 /2" STEEL ROD - 13 BLIND FLANGE PIPE SUPPORT DETAIL METER VAULT PLAN O (CLEANOUT) 2 � NOT TO SCALE — NOT TO SCALE — 14 TRANSFORMERS 2 1 VALVE BOX, TYP d ° f1 " z d d ° z 3) Olt a o 12 N 14 d r>y z 1 1 2" SCH ° I > 2'-0» 40 PVC l x y TYP 1 1 /2" 1 4'-0" 7 BALL VALVE O CD 0 5 N ° 6» 1 1 /2" CHECK 4 VALVE a 1 13 l I � � W I — — 9 ► i GALVANIZED STEEL 6 _ GRATING AND ANGLE PROVIDE BANDED c z 10 3 SUPPORT, WITH SST OPENING IN WEDGE ANCHORS GRATING FOR DISCHARGE PIPING 8 1 /2" 6 3 8 11 r d d d SEE DETAIL 2/U29, TYP d � '-6" PUMP ON ° d PUMP OFF 4 4 7 1 /2" w 1 '-6" SUBMERSIBLE 2 1 /2" W= 314931 MIN 6" COMPACTED CSBC PUMPWA �� C l ^- �- RECORD DRA WINGS PREPARED BY WHPACIFIC, SECTION A SECTION FEBRUARY 2010, BASED ON CONTRACTOR RECORDS. `� � 00355 4 4 NOT TO SCALE — NOT TO SCALE GIS— �SSION T EXPIRES 06/06/07 SURVEYED: SCALE: HORIZONTM: NAD 1983/1991 ., CITY O F R E N TO N DATE:4/17/06 � LLC 1 R R H 1 .1 M V DESIGNED: AS AS SHOWN ��� �w ,9� �� ,.�. CITY O F 1 720 Consultants, SOUTH LAKE WASHINGTON °�°°"' � ■ 720 Third Avenue, Suite 1200 LCA - w I I P Seattle, Washington 98104-1820 DRAWN: CAD _ RENTON ROADWAY IMPROVEMENTS " 12100 NE 195th St,Ste 300 Tel: (206) 505-3400 ONE INCH DATUM DRAWING NO: Bothell,WA 98011 CONSULTANTS Fax: (206) 505-3406 CHECKED: AT FULL SCALE Planning/Building/Public Works Dept. METER VAULT U3O 425-951-4800 Fax 425-951-4808 LCA IF NOT ONE INCH www.whpacific.com Formerly a Division of Berryman&Henigar N 0. R EV I S I 0 N BY DATE AP P R -PRO�LCA SCALE ACCORDINGLY DETAILS sHrfT. 1 1 6 205