Loading...
HomeMy WebLinkAboutWTR2703149_31 3/4"C, 3#8 (48OV) TO EXTERIOR PANEL XUJ9-1 /2A, j 4B, 6C (SEE SHEET U06 FOR ' CONTINUATION) O 0 � � POWER W 3 CORD 1KVA 2KVA 120V CONSTRUCTION NOTES S i SUMP PUMP INSTALL (2) 3/4" SCH 80 PVC CONDUITS IN TRENCH WITH MINIMUM 24 INCHES OF COVER FROM TOP OF CONDUIT TO FINISH GRADE. PLACE CONDUIT IN TRENCH WITH CONTROL DENSITY FILL APPROXIMATELY 6 INCHES ABOVE AND BELOW. SEPARATE CONDUITS BY A MINIMUM OF 12 INCHES. PLACE MARKER TAPE IN TRENCH ON TOP OF FILL. BACK FILL �sTst REMAINING TRENCH SPACE WITH NATIVE FILL. 3 INSTALL (1 ) 3/4" SCH 80 CONDUIT IN MINIMUM 12" WIDE TRENCH WITH MINIMUM 36" OF COVER FROM TOP OF CONDUIT TO FINISH GRADE. PLACE CONDUIT IN TRENCH WITH CONTROL DENSITY FILL APPROXIMATELY 6 INCHES 3/4"C, METER A i 3/4"C, ABOVE AND BELOW. PLACE MARKER TAPE IN TRENCH ON INTERCONNECT 3#12 (120V) TOP OF FILL. BACK FILL REMAINING TRENCH SPACE WITH CABLE NATIVE FILL. SEAL CONDUIT PENETRATIONS WITH GROUT OR SILICONE SEALANT TO LIMIT WATER PENETRATION. METER VAULT ELECTRICAL PLAN NOT TO SCALE — 24" INSTALL 3/4" EXTERIOR PLYWOOD BACKER BOARD IN + BACK OF ENCLOSURE WITH 4-1 /4" SST BOLTS (HEADS EQUIPMENT LIST ON OUTSIDE) O2 3 0 METER TRANSMITTER (FURNISHED WITH METER) 36" 0 CHART RECORDER z � m rz 5 0 NEMA 3R ENCLOSURE, PAINTED y o O ATTACH WITH 4-3/8" STEEL, ,� m z 304 SST MB 36 H x 24 W x 12 D y + + 0 120V POWER (3#12) AND SIGNAL x WIRE (FURNISHED WITH METER) 1 o THREADED FLANGE, c� N TOP AND BOTTOM 4-20mA SIGNAL WIRE, BELDEN N 4" SCH 40 GALV 2—CONDUCTOR WIRE WITH SHIELD 1 STEEL PIPE, SEE NOTE IN FLEX CONDUIT (J,� ►, ATTACH WITH 4-3/8" O Qvoucx 2tLEQ-rI%GLz ►Ks1oa Qmcwsoev > C ~ 36 304 SST WEDGE ANCHORS ro 36"x36"x7-1 /2" CONC BASE y TQ.e,N►s•, n�� e•so cyaar taco Qoa a �, (MIN 2500 PSI), REINFORCED SLOPE TO WITH 4 4# BARS E.W. DRAIN, TYP j a d d Lb d Q Q I d Q NOTE: imi SOLVENT CLEAN EXPOSED THREADS AND COAT 4 WITH COLD GALVANIZING COMPOUND. W= 314932 � C . METER READOUT z RECORD DRAWINGS ENCLOSURE 2 PREPARED BY WHPACIFIC, �' FEBRUARY 2010, BASED ��o ,per o3osss a NOT TO SCALE U30 ON CONTRACTOR RECORDS. .��SsG1 STV, G1� I EXPIRES 06/06/07 '3 1 RECORD DRAWING HCS 3.12.10MSV SuwEYED`:`sR SCALE. HORIZONTAL-L:N�VD 1988 �� DATE'4 17 06 BHC Consultants, LLC AS SHOWN •. CITY 0 E CITY OF RENTON / / WHPdClfll( ■ 720 Third Avenue, Suite 1200 DESIGNED: SOUTH LAKE WASHINGTON FlELDBOOK: Seattle, Washington 98104-1820 DRAWN: �D R E N TO N ROADWAY IMPROVEMENTS PAGE. " 12100 NE 195th St,Ste 300 lei■ Tel: (206) 505-3400 ONE INCH DATUM DRAWNG No. Bothell,WA 98011 CONSULTANTS Fax: (206) 505-3406 1 1 1 1 CHECKED: AT FULL SCALE Planning/Building/Public Works Dept. METER VAULT U31 425-951-4800 Fax 425-951-4808 LCA IF NOT ONE INCH www.whpacific.com Formerly Division of Berryman&Henigar NO. REVISION BY DATE LAPPR APPROVED: SCALE ACCORDINGLY SHEET,. OF, L�, ELECTRICAL 117 205 t