HomeMy WebLinkAboutWTR2703458_3 L. A PROPOSED CONDUIT TO EXISTING ATS - - ��of *♦a t { i PROPOSED LB FITTINGS. CORE DRILL AND SEAL PENETRATION. PROPOSED CONDUCTORS 22780 (TYPICAL OF TWO) FROM TRANSFORMER lar><8�° PROPOSED 400-AMP IONAL SOUTHWESTERN FACE OF GENERATOR DISCONNECT I --SWITCH EXISTING CONDUCTORS FROM EXISTING WELL #8 BUILDING TRANSFORMER TO BE REMOVED SIGNED. 07/01/09 EXTEND CONDUITS FROM TRANSFORMER TO PROPOSED 2� SECURE CABINET TO WALL 7'-p" MI r SEAL EXISTING CONDUIT USING ANCHOR BOLTS BUILDING ENTRANCE LOCATION. PROPOSED CONDUCTORS WA O f �I PENETRATION WITH GROUT (TYPICAL OF 2) FROM PROPOSED - • j GENERATOR PANEL EXISTING 90' LB TO BE ir8613REMOVED (TYPICAL OF 2) ! 2arets�f9 ti IONAL +�-- EXISTING CONDUITS FROM EXISTING TRANSFORMER. PROPOSED POSI-LOCK TO BE MODIFIED. RECEPTACLE CABINET. ' µ„ SIGNED. 07101109 ! SEE ONE-LINE DIAGRAM 1 _ FOR DETAILS. 4'-6" I ! - INSTALL LB AND NEW EXISTING GENERATOR CONDUIT AS NECESSARY TO EXISTING CONDUCTORS °e a REACH CABINET a - M RECEPTACLE TO BE REMOVED FROM TRANSFORMER TO BE REMOVED EXISTING 2Y" GRS CONDUIT PENETRATION TO BE RE-USED. CONTRACTOR SHALL INCREASE N 0 DIAMETER OF EXISTING CONDUIT PENETRATION COVER HOLE IN ENCLOSURE EXISTING CONFIGURATION FOR INSTALLATION OF PROPOSED 3 " CONDUIT. PROPOSED CONFIGURATION AFTER REMOVAL OF NO SCALE NO SCALE CONDUCTORS EXISTING 2 " CONDUIT TO BE REPLACED WITH PROPOSED 3 " CONDUIT PROPOSED 400-AMP GENERATOR DISCONNECT SWITCH - NEMA 3R ENCLOSURE, 600 VOLT RATED, HEAVY DUTY RATED CIRCUIT BREAKER EXISTING GENERATOR RECEPTACLE CONNECTION TO BE REPLACED. RETURN WITH NEUTRAL INCLUDED. SIEMENS OR EQUAL. TO CITY AFTER REMOVAL. INSTALL PROPOSED 400 AMP, 600 VAC, CAM PROPOSED CONDUCTORS TYPE, POSI-LOCK RECEPTACLE CABINET. SKYLINE MANUFACTURING MODEL FROM PROPOSED #E0400-1662 OR EQUAL. SEE DETAIL THIS SHEET. GENERATOR PANEL Z (1)-3 Y2" CONDUIT. CONDUIT SHALL CONTAIN (6)-#250 MCM AND (2)-#250 O Z 400 A MCM NEUTRAL AND #3 GROUND. #250 MCM CONDUCTORS SHALL BE EXISTING 12.47KV DISTRIBUTION CONDUCTORS TYP. OF 3 PHASES 3P INSTALLED AS PARALLEL CIRCUIT PER NEC 310.4 REQUIREMENTS. V L EXISTING MANUAL TRANSFER SWITCH WIRING DETAIL NO SCALE Z ' a' PRIMARY FUSES EXISTING MCC BUS Q QEXISTING PAD-MOUNT TRANSFORMER W 12.24KV-277 480V 30 300 KVA 600A J V / I 3P #1/0 GROUND ATS W YY z � EXISTING I I O CT'S I � STATION ATS LOCATED INSIDE PUMP o�' 0 EXISTING PRIMARY 30AI(C r W METERING CABINET 3P I 600A I �--1 Uj (2)-2Y" CONDUITS. EACH CONDUIT SHALL CONTAIN (3)-#350 MCM AND M� I - (1)-#350 MCM NEUTRAL. INSTALL CONDUCTORS PER N.E.C.. EXTENSION OF EXISTING PRIMARY EXISTING CONDUITS REQUIRED. SEE CONFIGURATION DETAIL THIS SHEET. _ V METER — — EXISTING WELL #8 BUILDING UNDERGROUND SITE LEGEND PROPOSED (3)-#2 MV CABLES AND 1 2 MV GROUND EXISTING PAD-MOU ( )-# I EF EXISTING POWER VAULT TRANSFOR IN EXISTING VAULT. 3/"X8' COPPER CLAD STEEL GROUND ROD. SEE GROUNDING mot, ONE LINE DIAGRAM - ---- ---- — — DETAILS ON SHEET 1 EXISTING METERING CABINET NO SCALE PROPOSED CONDUIT EXISTING POWER VAULT E N G I N E E R S APPROXIdkATE'LOCATION FROM PLANNERS MEDIUM VOLTAGE _ WHICH PHOTO WAS TAKEN, S C I E N T I S T ANG EXISTING METERING CABINS RH2 ENGINEERING,INC. AUTOMATIC TRANSFER SWITCH �?" _ http://www.rh2.com UNDERGROUND COND I '. http://www.rh2.com mailbox@rh2.com TO BE RE-USED. MODIFLCATI_ ELECTRICAL1.800.720.8052 TO CONDUIT NEC 'Y TO NO SCALE COMPLETE I TION. BELLINGHAM OFFICE 360.676.0836 EXISTING GENERATOR 454 West Horton Road RECEPTACLE. SEE NOTE O BOTHELL OFFICE EXISTING PAD MOUNT 425.951.5400 TRANSFORMER 1 12100 NE 195th Street, Suite 100 t SHEET NOTES - - = TCH OFFICE x � , "'` �;t"• r � EAST WENA Simon reSuite 509.886.2900 300 S St 5 PORT ORCHARD OFFICE 360.876.7960 to ALL SCHEDULE POWER OUTAGES TO THIS FACILITY MUST BE APPROVED BY THE OWNER IN ADVANCE. THE CONTRACTOR SHALL MAKE A WRITTEN REQUEST TO THE OWNER 72 HOURS IN ADVANCE OF THE DESIRED TIME. 600 Kitsap Street, Suite 101 I ys rya - 20 THIS FACILITY MAY BE TAKEN OUT OF SERVICE UNDER A POWER OUTAGE FOR A MAXIMUM PERIOD OF 8 HOURS. AFTER 8 HOURS THE STATION MUST BE MADE OPERATIONAL UNDER UTILITY POWER. IF IMPROVEMENTS i SCALE: SHOWN ARE NOT COMPLETE THE CONTRACTOR CAN REQUEST A SECOND OUTAGE. KOM :. _ 0 1 2„ 30 THIS FACILITY MUST BE OPERATIONAL UNDER UTILITY POWER SEVEN DAYS A WEEK BETWEEN 5:00 PM AND 7:OOAM UNLESS SPECIAL PERMISSION IS GRANTED BY THE OWNER OR AN UNSCHEDULED POWER OUTAGE. A\ EXISTING TRANSFORMER PAD DRAWING IS NOT TO SCALE s A IF BAR IS NOT 2" LONG 4o THE CONTRACTOR MUST DEMONSTRATE TO THE OWNER THAT THE PROPOSED RECEPTACLE CABINET IS FUNCTIONING PROPERLY AND THE PHASE ROTATION MATCHES THE UTILITY POWER. THE OWNER WILL PROVIDE A owc No. - PLOT: 20 PORTABLE GENERATOR AND CORD SET FOR THE DEMONSTRATION. CONTRACTOR SHALL COORDINATE WITH THE OWNER 72 HOURS IN ADVANCE OF THE TEST. A B ENGINEER:MM E02 05 POSI-LOCK RECEPTACLE SHALL BE MALE TYPE TO MATCH THE OWNER'S PLUGS WHICH ARE FEMALE. CONTRACTOR SHALL VERIFY COMPATIBILITY WITH OWNER DURING SUBMITTAL PROCESS. REVIEWED:MM ` 6 REMOVE EXISTING GENERATOR RECEPTACLE AND RETURN TO CITY SHOP LOCATED AT 3555 NE SECOND STREET, RENTON, WA. EXISTING TRANSFORMER EXISTING GENERATOR RECEPTACLE DATE: FEB 4, 20,D sHE3o. NO SCALE CLIENT: REN ADDENDUM / ISSUED FOR CONSTRUCTION CMR CMR 02/04/10 JOB NO, 108-109 4 NO. REVISION BY REVIEW DATE FILENAME:PSEU—D—CO2