Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WTR2703458_4
I L. AS L \ I SITE LEGEND 9�0 :'8$A�� SON WAY NE \\� BRQI�I \ \8 \\� • I SURFACE FEATURES (EXISTING) LINETYPES (EXISTING) 22780 Sr _ \ ' I I ti SYMBOL DESCRIPTION +t3i$e�IBTl%tS \ \\,J I UTILITY LINETYPE DESCRIPTION `�Y�IOIAL _ N \ I C�c= ROCK FACING � EXISTING BOOSTER PUMP STATION MOTOR CONTROL �,;� TREE (CONIFER) POWER (UNDERGROUND) SIGNED: 07/O1/09POWER (OVERHEAD) CENTER CONTAINING EXISTING LIGHTING PANELBOARD. V �. INSTALL PROPOSED 20 AMP CIRCUIT BREAKER IN TREE (DECIDUOUS) s_ SANITARY SEWER T \� EXISTING PANELBOARD FOR POWERING PROPOSED yy W WATER (SIZE DENOTED ON PLANS �F "'8Z TRANSFORMER CONDENSATION HEATERS. TERMINATE � WATER MANHOLE PROPOSED CONDUCTORS AT EXISTING PANELBOARD. FIRE HYDRANT sT - STORM DRAIN/CULVERT , \ SIG slc SIGNAL © POWER VAULT 38613 EXISTING CONDUIT AND CONDUCTORS BETWEEN EXISTING —_— - EXISTING FENCE $aQ78Tta`o - n / EXTERIOR RECEPTACLE AND EXISTING LIGHTING FM METERING CABINET —_ roNAL g�� • 3' CLEARANCE REQUIRED \ // PANELBOARD. INSTALL PROPOSED CONDENSATION HEATER .� EXISTING ELECTRICAL \ \ POWER SUPPLY CONDUCTORS IN EXISTING CONDUIT. HANDHOLE SIGNED: 07/01/09 y/ HANDHOLE. DO NOT DISTURB. \ - o" \ ; _ _ _ _ _ _ ___ _ _ SURFACE FEATURES (PROPOSED) LINETYPES (PROPOSED) Y SYMBOL DESCRIPTION UTILITY LINETYPE DESCRIPTION 1 • - I PROPOSED TRANSFORMER AND VAULT MV MEDIUM VOLTAGE PROPOSED CONDUIT -__ SHEET NOTES N Iry 0ALL SCHEDULE POWER OUTAGES TO THIS FACILITY MUST BE APPROVED BY THE OWNER IN ADVANCE. THE CONTRACTOR SHALL MAKE A WRITTEN a \ REQUEST OF THE OWNER 72 HOURS IN ADVANCE TO THE DESIRED TIME. L� EXISTING PRIMARY ME�ING CABINET O \\ W �= r/ THIS FACILITY MAY BE TAKEN OUT OF SERVICE UNDER A POWER OUTAGE FOR A MAXIMUM PERIOD OF 96 HOURS. AFTER 96 HOURS THE STATION MUST BE MADE OPERATIONAL UNDER UTILITY POWER. / 30 EXISTING POWER VAULT THIS FACILITY MUST BE OPERATIONAL UNDER UTILITY POWER SEVEN DAYS A WEEK BETWEEN 5:00 PM AND 7:OOAM UNLESS SPECIAL PERMISSION IS Z � A �\ ° GRANTED BY THE OWNER OR AN UNSCHEDULED POWER OUTAGE. W PROPOSED PAD-MOUNT SERVICE TRANSFORMER AND ,, 4 REMOVE AND DISPOSE EXISTING PAD-MOUNT TRANSFORMER, TRANSFORMER VAULT AND PAD. Z O VAULT. REMOVE EXISTING TRANSFORMER AND VAULT. \ `y o ° `t ^� 0 W SEE TYPICAL CONCRETE PAD AND VAULT DETAIL THIS \ 50 SPACE AVAILABLE FOR LOCATING PROPOSED TRANSFORMER AND VAULT IS LIMITED. CONTRACTOR SHALL VERIFY CONSTRUCTABILITY PRIOR TO STARTING O Q SHEET. ,o ' .\\\\ EXCAVATION IN THIS AREA. WATER RESERVOIR LOCATION OF EXISTING BOOSTER `o �� Z04 PUMP STATION CONDUIT PENETRATION W � PROPOSED JUNCTION BOX MOUNTED TO RECEPTACLEEXISTING I. DO 0. ��7 `\ BOOSTER PUMP STATION EXTERIOR WALL. NOT DISTURB. W AND RECEPTACLE. SEE PHOTO THIS _ V SHEET FOR DETAILS. ^ 10 EXISTING DAMAGED NOT AND CONDUIT TO BE EXISTING PUMP STATION s �. Wcr REPLACED. CONTRACTOR SHALL INSTALL PROPOSED JUNCTION �\ PROPOSED J" GRC PROPOSED CONDUIT \ �\ BOX ON WALL BELOW EXISTING RECEPTACLE. CONTRACTOR �T CONDUIT BETWEEN I� CONTAINING (2)-#12, (1)-#12 \ \ ��\ \ ��,5 SHALL CONNECT PROPOSED CONDUIT BETWEEN JUNCTION BOX a` RECEPTACLE AND W IL W GIRD CONDUCTORS. \ O \ �. AND RECEPTACLE. CONTRACTOR SHALL CONNECT PROPOSED ~ JUNCTION BOX. \0 \ CONDUIT FROM PROPOSED TRANSFORMER CONDENSATION s Z HEATERS TO JUNCTION BOX. CONTRACTOR SHALL CONNECT ti O W PROPOSED REPAIRED CONDUIT TO JUNCTION BOX. CONTRACTOR �' 'sF PROPOSED " CONDUIT - j AND CONDUCTORS TO SHALL INSTALL PROPOSED TRANSFORMER CONDENSATION HEATER >' O CONDUCTORS IN EXISTING CONDUIT BETWEEN EXISTING LIGHTING 1' � TRANSFORMER I"-� PANELBOARD AND BUILDING EXTERIOR. CONTRACTOR SHALL ., .�+ CONDENSATION J Q DISCONNECT AND RECONNECT EXISTING CONDUCTORS AT R � -:-� ��r � � � ��; HEATER. cn RECEPTACLE AS NECESSARY FOR REPLACING DAMAGED CONDUIT. v - ° PROPOSED CONDUIT FROM s�� \ ' �`�`� , REPAIRED CONDUIT TO JUNCTION BOX. Y;. ' ,: aN ,G, � :'��.°�..._t��Kv ° EXISTING GENERATOR EXISTING BOOSTER PUMP STATION CONDUIT A cv l 3 BUILDING NO SCALE EXISTING 750 KVA STEP-UP PAD-MOUNT TRANSFORMER. MANUFACTURER OF 0 PRECAST SLAB ELECTRICAL SITE PLAN i EXISTING TRANSFORMER IS COOPER POWER SYSTEMS. CONTRACTOR SHALL INSTALL 0D FINISHED GRADE 1" = 10' (2) PROPOSED TRANSFORMER CONDENSATION HEATERS AND THERMOSTATS IN P�A EXISTING TRANSFORMER. ONE (1) CONDENSATION HEATER AND THERMOSTAT SHALL p ACCESS COVER E IN I N E E R S BE LOCATED IN BOTH THE PRIMARY AND SECONDARY COMPARTMENTS. �' PLANNERS CONTRACTOR SHALL TERMINATE PROPOSED CONDENSATION HEATER POWER SUPPLY SCIENTISTS EXISTING 12.47KV DISTRIBUTION CONDUCTORS TYP. OF 3 PHASESL EXISTING PARALLEL #300 MCC CONDUCTORS TO BE RE-USED. I CONDUCTORS AT EXISTING TRANSFORMER. SEE SPECIFICATIONS FOR MORE 3" INFORMATION REGARDING PROPOSED CONDENSATION HEATER. �' \\ DISCONNECT FROM EXISTING TRANSFORMER AND CONNECT TO � RH2 ENGINEERING,INC. PROPOSED (3)-#1/0 MV AND PROPOSED TRANSFORMER. 3 CONDUCTORS PER PHASE TYPICAL. i 8" http://www.rh2.com EXISTING O GROUND IN 1 CONCRETE PAD AND \ /� mailbox@rh2.com EXISTING CONDUIT c� \� 1.800.720.8052 PRIMARY FUSES Z ON POLE PROPOSED LOAD 8`0 PROPOSED PAD-MOUNT TRANSFORMER BREAK ELBOWS VAULT NOTES BELL OFFICE � 360.676.0836 0836 12.24KV-277 480V 30 750 KVA m 454 West Horton Road PROPOSED BOTHELL OFFICE LOAD BREAK ELBOWS y y #2/0 GROUND 1 W 0 PRECAST BOX SECTION O 425.951.5400 EXISTING 1 �? 0 PRECAST SLAB SHALL BE SIMILAR TO THE REQUIREMENTS OF 0 0 12100 NE 195th Street, Suite 100 cD PUGET SOUND ENERGY (PSE). EXISTING PRIMARY I CTS� I I Z 6 JEAST 86WE00NATCHEE OFFICE METERING CABINET 100A 3P a< PROVIDE GROUND RODS AND CLAMPS. SEE ONE-LINE DIAGRAM FOR 300 Simon Street, Suite 5 O — J GROUND WIRE SIZE. 3/4" CRUSHED ROCK PORT ORCHARD OFFICE _ 1 9 0 360.876.7960 M� cm O 600 Kitsop Street, Suite 101 EXISTING PRIMARY I 1 m 0 MASTIC SEALANT IS REQUIRED AT JOINTS. 0 METER — SCALE: SHOWN CONDUIT TERMINATORS '\\— UNDERGROUND p TOP SURFACE OF PRECAST SLAB SHALL BE SET THREE INCHES GROUND ROD TYP. OF 2 LIGHTING ARRESTOR Z ABOVE FINISHED GRADE. 1" CAPPED PVC CONDUIT ^ ��a. ( ) OB 0 1" 2" B N DRAWING IS NOT TO SCALE X IF BAR IS NOT 2" LONG 1 ``' O PRECAST BOX MEASURES APPROXIMATELY 7'W x 71 x 3'-6"D. PLOT: 20 DWG NO. ENGINEER:MM E03 EXISTING POWER VAULT -- — REVIEWED:MM - - TYP I CAL CONCRETE PAD & VAULT DATE: FEB 4, 2010 SHEET NO. "X8' COPPER CLAD STEEL GROUND ROD. NOT TO SCALE CLIENT: REN 4 ONE-LINE DIAGRAM 3/4SEE GROUNDING DETAILS ON SHEET 1. ADDENDUM / ISSUED FOR CONSTRUCTION CMR CMR 02/04/10 JOB NO.: 108-109 4 NOT TO SCALE N0. REVISION BY REVIEW DATE FILENAME:PSEU-D—COI