Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WTR2703488_6
3 JUNCTION BOX, "JB-1" EXISTING ANTENNAS PROPOSED ALUMINUM H. 1 11 1t I r,+ f, VENT TO REPLACE PROPOSED INNER EXISTING ACCESS EXISTING VENT GUARDRAIL ,ot wasgj� %f EXISTING ANTENNA HATCH PROPOSED OUTER GUARDRAIL a�`� C7 r EXISTING SPIRAL EXISTING ANTENNA STAIRCASE AND RAIL 16727 i C8 - EXISTING ROOF I �` at3Rsa$9� ACCESS LANDING sl�` C1 --- 101.5' ABOVE GRADE o _ SIGNED. 04123110 f; 3 J3 PROPOSED ACCESS HATCH INTRUSION 1� M: ., SWITCH ��04 cF ..s0 C7 0 jl` SWING GATE, C8 45317 TYPICAL - $gC194s$`V EXISTING SPIRAL SIGNED. 04123110 STAIRS PROPOSED ALUMINUM VENT TO \\\ 'Y REPLACE EXISTING VENT EXISTING RESERVOIR v SHELL � � O PROPOSED INNER lit GUARDRAIL ' J3 6 \ PROPOSED ELECTRICAL } CABINET, "EC-2" \ PROPOSED COVER C8 z r EXISTING YAGI ANTENNA, PROPOSED CONDUITS. CONTRACTOR TO BE REMOVED. PROPOSED OUTER SHALL SECURE PROPOSED \\ I a GUARDRAIL / C C5 CONDUITS BENEATH STAIRS TO \�\ O EXISTING CONDUIT/CABLE SUPPORT \\ O V J BRACKETS WITH PROPOSED \\ Q EXISTING ROOF 0 � 4 CONDUIT CLAMPS. SEE DWG NO. \\ p E02 FOR DETAILS. EXISTING �+ ACCESS HATCH. / © ANTENNA „� N 1 EXISTING ROOF ACCESS J1 w HATCH JUNCTION BOX 1:42 0 EXISTING w W C J1 ELECTRICAL PROPOSED WER REPEATER J C1 CABINET, "EC-1" EXISTING CONDUIT CONDUIT J2 AND SPARE W PROPOSED REVISED TO CONFORM AND CABLE TRAY. CONDUIT C8 SEE SEE NOTE 5 FOR e O SEE ELECTRICAL NOTES P1 CONDUIT TEE TO CONSTRUCTION RECORDS DETAILS. C1 CONNECTION. � ' • EXISTING x 0 SEE O �^ 03/22 11 1 LADDER ACCESS PROPOSED CONDUIT EXISTING COVER AND CABLE TRAY. ®,�__._- - Q P11 �> © RH2 ENGINEERING I C. DATE _ �y w SPARE CONDUIT STUB UP. C END CONDUIT 2" ABOVE UPPER PROPOSED INTRUSION DISABLE KEYSWITCH C6 0 f% C2 V W i LANDING PLATFORM AND CAP. ENCLOSURE SECURED TO EXISTING ELECTRICAL EQUIPMENT COVER SUPPORT. SEE DETAIL ON QD C4 DWG N0. E03. L �� � EXISTING ELECTRICAL CABINET DOOR I r.� �:1 EXISTING COVER W Cn 2 1 TO BE REPLACED. SEE g EXISTING LOWER C3 J3 EXISTING UPPER LANDING 03 ACCESS LANDING AND GUARDRAIL 2; C3 C7 le � l EXISTING LOWER z ; PROPOSED NEMA 4X, 12"W ACCESS LANDING ! tI I C9 ' PROPOSED PROPOSED COVER PROPOSED LOWER ACCESS VANDAL SHIELD, I C4 AND GUARDRAIL LANDING HATCH INTRUSION SEE q X 12"H X 10"D JUNCTION j� C2 BOX, "JB-1". MOUNT TO I C2 EXISTING TELEMETRY PANEL, "RTU". SEE EXISTING RESERVOIR SWITCH C2 INSIDE OF GUARDRAIL WITH DETAIL N N FOUNDATION e PROPOSED STAINLESS STEEL DE L 0 DWG G 0. E03 PROPOSED VANDAL SHIELD . HARDWARE. C C6 ELECTRICAL CABINET�/ 0 _ INTRUSION SWITCH INTRUSION SWITCHES RESERVOIR ELECTRICAL PLAN P11 S O ENGINEERS Y° _ 1�_O" PROPOSED PLANNERS EXISTING TELEMETRY ELECTRICAL SCIENTISTS F PANEL, "RTU". EXISTING CABINET, "EC-2" 03 ELECTRICAL C5 RH2 ENGINEERING,INC. C9 CABINET, "EC-1" http://www.rh2.com ELECTRICAL NOTES mailbox@rh2.com 1.800.720.8052 1. EXISTING LIGHT FIXTURE AND MOUNTING BRACKETS (TYPICAL). CONTRACTOR SHALL REPLACE RESERVOIR ELECTRICAL ELEVATION� BELLINGHAM 360.676.0836 EXISTING LIGHT FIXTURE AND MOUNTING BRACKETS WITH PROPOSED LIGHT FIXTURE AND 4. EXISTING WATER TELEMETRY ANTENNA TO REMAIN. INSTALL CONDUIT BETWEEN `EC-1" AND BASE OF 454 West Horton Road MOUNTING BRACKETS. SEE DETAILS ON DWG NO. E02. ANTENNA. INSTALL EXISTING ANTENNA CABLE IN PROPOSED CONDUIT. 1'-0" BOTHELL 42S.951.5400 5. EXISTING CONDUIT AND CABLE TRAY. REMOVE TRAY AS NECESSARY FOR INSTALLATION OF POWER CONDUIT AND CONDUCTOR SCHEDULE 12100 NE 195th Street, Suite 100 2. PROPOSED LIGHT SWITCH FOR INTERIOR LIGHT FIXTURE. MOUNT SWITCH ON INSIDE GUARDRAIL PROPOSED CONDUITS. REINSTALL TRAY AFTER INSTALLATION IS COMPLETE. SEE DWG NO. E02 FOR EAST WITH STAINLESS STEEL HARDWARE. CONTRACTOR SHALL SPLICE EXISTING CONDUCTORS WITH CIRCUIT SOURCE DESTINATION TRADE SIZE QUANTITY CONDUCTORS NOTES CONDUIT ROUTING DETAIL. WENATCHEE so9sas.zeoo PROPOSED LIGHT SWITCH CONDUCTORS IN EXISTING ROOF ACCESS HATCH JUNCTION BOX. SEE Pl EXISTING RESERVOIR ROOF ACCESS HATCH JUNCTION BOX ROOF ACCESS HATCH LIGHT SWITCH 3/4" (2) - #12, (1) - #12 GRD 300 Simon Street, Suite 5 DETAIL D ON DWG N0. E02. 6 6. SEE RESERVOIR RECOATING NOTES ON DWG NO. SO4 FOR COATING REQUIREMENTS AROUND ALL �i P2 EXISTING ELECTRICAL CABINET, "EC-1", PANELBOARD PROPOSED ELECTRICAL CABINET, "EC-2", LOAD CENTER, "L2" 1" (2) - #8, (1) - #8 N, (1) - #10 GRD SEE DWG N0. E03 FOR LOCATION RICHLAND 509.946.51e1 3,. 3. EXISTING YAGI ANTENNA AND ASSOCIATED HARDWARE AND CABLE TO BE REMOVED AND ELECTRICAL EQUIPMENT. 114 Columbio Point Drive, Suite C RETURNED TO THE CITY. CONTRACTOR SHALL REMOVE EXISTING ANTENNA, MOUNTING 23 PROPOSED ELECTRICAL CABINET, "EC-2", LOAD CENTER, 12" EXISTING SEWER REPEATER PANEL 3/4" (2) - #12, (1) - #12 GRD SEE DWG NO. E03 FOR LOCATION SILVERDA•E wo,7s 79m HARDWARE, AND ANTENNA COAXIAL CABLE BETWEEN EXISTING ANTENNA AND EXISTING QC 7. SEE DWG NO. E03 FOR ELECTRICAL EQUIPMENT AND INSTRUMENTATION SCHEDULE. P4 PROPOSED ELECTRICAL CABINET, "EC-2", LOAD CENTER, 12" ELECTRICAL CABINET, "EC-2", RECEPTACLE 3/4" (2) - #12, (1) - #12 GRD SEE DWG NO. E03 FOR LOCATION 2021 NW Mhyre Rd, Suite 107 ELECTRICAL CABINET "EC-1". P8 EXISTING ELECTRICAL CABINET, "EC-1" PROPOSED ELECTRICAL CABINET, "EC-2" 1 1/2" (1) - NYLON PULLCORD SPARE CONDUIT. SEE DWG NO. E03 TACOMA 253.272.30S9 621 Pacific Avenue Suite 104 CONTROL CONDUIT AND CONDUCTOR SCHEDULE P9 EXISTING ELECTRICAL CABINET, "EC-1" PROPOSED ELECTRICAL CABINET, "EC-2" 1 1/2" (1) - NYLON PULLCORD SPARE CONDUIT. SEE DWG NO. E03 CIRCUIT SOURCE DESTINATION TRADE SIZE (QUANTITY) CONDUCTORS NOTES P10 EXISTING ELECTRICAL CABINET, "EC-1" PROPOSED ELECTRICAL CABINET, "EC-2" 1 1/2" (1) - NYLON PULLCORD SPARE CONDUIT. SEE DWG NO. E03 SCALE: SHOWN C1 ROOF ACCESS HATCH INTRUSION ALARM SWITCH CONDUIT TEE ADAPTER 3/4" (2) - #14, (1) - #14 GRD -& P11 EXISTING ELECTRICAL CABINET, "EC-1" RESERVOIR STAIRWAY LIGHT SWITCH 3/4" (2) - #12, (1) - #12 GRDKQQN C2A VANDAL SHIELD INTRUSION ALARM SWITCH LOWER ACCESS LANDING HATCH INTRUSION ALARM SWITCH 3/4" (2) - #14, (1) - #14 GRD CIRCUITS "C2A", AND "C2B" SHARE CONDUIT "C2" 0 1" 2"INSTRUMENTATION CONDUIT AND CONDUCTOR SCHEDULE DRAWING IS NOT TO SCALE C2B LOWER ACCESS LANDING HATCH INTRUSION ALARM SWITCH CONDUIT TEE CONNECTOR 3/4" (4) - #14, (1) - #14 GRD CIRCUITS "C2A", AND "C2B" SHARE CONDUIT "C2" IF BAR IS NOT 2" LONG CIRCUIT SOURCE DESTINATION TRADE SIZE (QUANTITY) CONDUCTORS NOTES C3 CONDUIT TEE ADAPTER EXISTING TELEMETRY PANEL, "RTU" 3/4" (8) - #14, (1) - #14 GRD CIRCUITS "Cl", AND "C2" SHARE CONDUIT "C3" J1 EXISTING WATER SYSTEM ANTENNA EXISTING TELEMETRY PANEL, "RTU" 1 1/2" (1) - ANTENNA CABLE PULL EXISTING CABLE(S) THROUGH PROPOSED CONDUIT. PLOT: 48 DWG NO. " C4 EXISTING TELEMETRY PANEL, RTU" EXISTING ELECTRICAL CABINET, EC-1", INTRUSION ALARM SWITCH 3/4 (2) - #14, (1) - #14 GRD J2 EXISTING SEWER REPEATER PANEL EXISTING SEWER REPEATER CONDUIT 1" 1 ENGINEER:DY E01 005 EXISTING TELEMETRY PANEL, RTU ELECTRICAL CABINET, EC-2 , INTRUSION ALARM SWITCH 3 4 O ( ) - SEWER REPEATER CABLE PULL EXISTING CABLE(S) THROUGH PROPOSED CONDUIT. " " " " / " (2) - #14, (1) - #14 GRD NOT SHOWN THIS SHEET, SEE DWG NO. E03 FOR LOCATION. REVIEWED:CMR C6 EXISTING TELEMETRY PANEL "RTU" INTRUSION DISABLE KEYSWITCH 3/4" (2) - #14 (1) - #14 GRD J3 JUNCTION BOX "JB-1" EXISTING ELECTRICAL CABINET "EC-1" (1) - 1" SHEET NO. O (1) - PULL CORD EACH CONDUIT SPARE CONDUITS FOR FUTURE METER READ SYSTEM DATE: MAR 23, 2011 C7 EXISTING ELECTRICAL CABINET, "EC-1" UPPER LANDING PLATFORM (2) - 1" (1)-PULL CORD EACH CONDUIT CAP SPARE CONDUITS 2" ABOVE PLATFORM (1) - 2" 06 CLIENT: REN C8 ELECTRICAL CABINET, "EC-2" UPPER LANDING PLATFORM (2) - 1" (1)-PULL CORD EACH CONDUIT CAP SPARE CONDUITS 2" ABOVE PLATFORM REVISED TO CONFORM TO CONSTRUCTION RECORDS MWB CMR 03/22/11 JOB NO.: 109-062 09 C9 EXISTING TELEMETRY PANEL, "RTU" INTRUSION ALARM HORN 3/4" (2) - #14, (1) - #14 GRD NO. REVISION BY REVIEW DATE FILENAME:WHR-D-ELEC01