Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AD_IFC 090__en_HART_001101__R01
KR (3 ©KROHNE 11/2000 - Remote Operation WE'VEGOT Instructions ' : HART Communicator 275 ABILITY Asset Management Solutions (AMS) IFC090 KROHNE s KR O H N E KROHNE Messtechnik GmbH&Co. KG Ludwig-Kroh ne-Str.5• D-47058 Duisburg 1/8 Tel.:0203-301 0• Fax:0203-301 389 -e-mail:krohne@krohne.de Remote Operation Instructions IFC090 HART 1 General Information 3 2 IDs and Revision numbers 4 3 Implementation Peculiarities 4 4 HART Communicator 275 (HC275) 4 4.1 Installation 4 4.2 Operating 5 5 Asset Management Solutions (AMS) 5 5.1 Installation 5 5.2 Operating 5 KR O H N E KROHNE Messtechnik GmbH&Co. KG -Ludwig-Kroh ne-Str.5• D-47058 Duisburg 2/8 Tel.:0203-301 0• Fax:0203-301 389 -e-mail:krohne@krohne.de Remote Operation Instructions IFC090 HART 1 General Information The IFC090 is a two-wire transmitter with 4...20mA current output and HART capability. Dependent on device implementation it is available with active current output ('Standard + HART', 'Modis-3') or passive current output (`Standard + HART', `Modis-1', 'Modis-2'). General Characteristics of the IFC090 HART interface: 00 Multidrop Mode is supported 00 Burst Mode is not supported Electrical connection: Refer to sections 2.1, 2.2, 2.6 of the "Installation and Operating Instructions Electromagnetic flowmeters IFC 090 K/F" (KROHNE)—for'Standard + HART' device implementation, and to sections 4-6 of the "Information about IFC 090i (Modis-devices)" (KROHNE)—for'Modis' instrument implementations. There are two ways of using the HART communication: a)As a point-to-point connection between the IFC090 and the HART master equipment. The instrument may be equipped with either active or passive current output ('Modis') or be configured with desired current output('Standard + HART'). Point-to-Point Analog/Digital Mode Primary Master s, HART _.,�..-------�— Analog Modem HART Terminal) 2500 4...20 mA J I� IFC090 ,a C Addr.0 Secondary Master - (active Current output) b)As a multipoint connection (multidrop)with up to 15 devices (IFC090 or other HART equipment) in parallel. The instruments must be equipped (or configured)with passive current output. KR O H N E KROHNE Messtechnik GmbH&Co. KG -Ludwig-Kroh ne-Str.5• D-47058 Duisburg 3/8 Tel.:0203-301 0• Fax:0203-301 389 -e-mail:krohne@krohne.de Remote Operation Instructions IFC090 HART Multidrop Mode �� ---- _ Primary Master 011 -- HART Modem HART Lbq- 25001 �j�,•.�y, � Terminal) 4 mA 4 mA Terminal I Secondary Master _ '1 Up to 15 1 .-. Slaves 11 n ti7C ~ IFC090 IFC090 Addr.>0 Addr.>0 (passive Current Output) (passive Current Output) 2 IDs and Revision numbers The HART Device Descriptions described in this document have the following IDs and revision numbers: Manufacturer ID: 69 (Ox45) Device Type: 244 (OxF4) Device Revision: 2 DD Revision: 1 HART Universal Revision: 5 HC 275 OS Revision: 4.9 AMS Version: 5.0 For information about Transmitter Revisions and related Device Descriptions refer to the KROHNE HART Device List. 3 Implementation Peculiarities Variables and functions/processes of the Service Menu are not maintained by the instrument HART@ application layer. Still a subset of service parameters is transferred via bus (only reading is possible): it applies to variables that control the limits, availability, etc. of maintenance data. 4 HART Communicator 275 (HC275) 4.1 Installation The HC275 has to be programmed with the IFC090 HART Device Description. Otherwise the HC275 user will work with the instrument as a generic one thus loosing opportunity for entire instrument control. KR O H N E KROHNE Messtechnik GmbH&Co. KG -Ludwig-Kroh ne-Str.5• D-47058 Duisburg 4/8 Tel.:0203-301 0• Fax:0203-301 389 -e-mail:krohne@krohne.de Remote Operation Instructions IFC090 HART 4.2 Operating Refer to the IFC090 Menu Tree HC275 (Attachment A). The IFC090 operation via HC275 is made quite close to the manual instrument control via keypad. The online help of each parameter contains its function number as a reference to the device's local display and the "Installation and Operating Instructions". Parameter protection via password (Entry Code) is the same as on local display. Please refer to the online help for valid symbols according to device's keypad. While saving configuration to HC275 from connected instrument, some crucial service variables (refer to section 2) are also stored. Hence in the offline mode their values cannot be changed (and will not be sent to device), but are shown to HC275 user and control assignments for maintenance data. As soon as service functionality is not available via HART transmitter, the difference between "standard configuration" of HC275 and its "full configuration" consists in some read-only parameters (sensor limits, device modules' IDs, etc.)that are either transferred to AMS ("full configuration")or are shown on AMS tabs as empty fields ("standard configuration"). 5 Asset Management Solutions (AMS) 5.1 Installation If the IFC090 Device Description is not already installed on the AMS System a so called Installation Kit IFC090 HART AMS is needed (available on floppy disk from KROHNE or as download from KROHNE Internet page). For installing the DID with the Installation Kit refer to the `AMS User's Guide"section 1 Managing HART Devices"/ `Adding new Device Types to AMS"l 'Install Device Types Manually". 5.2 Operating Refer to the IFC090 Menu Tree AMS (Attachment B). Due to AMS requirements and conventions the IFC090 operation differs a little from operation with HC275 and via local keypad. The online help of each parameter contains its function number as a reference to the device's local display and the "Installation and Operating Instructions". Parameter protection via password (Entry Code) is the same as on local display. Please refer to the online help for valid symbols according to device's keypad. KR O H N E KROHNE Messtechnik GmbH&Co. KG -Ludwig-Kroh ne-Str.5• D-47058 Duisburg 5/8 Tel.:0203-301 0• Fax:0203-301 389 -e-mail:krohne@krohne.de Remote Operation Instructions IFC090 HART Attachment A IFC090 Menu Tree HC275 1 Raw Flow 1 Current Output Value 1 Process 2 Smoothed Flow 2 PV%Range Variables 3 Positive Totalizer 3P'Pulse Output Value 4 Negative Totalizer 4°p'Control/Status B 1 5 Totalizers' Sum 5°p'Control/Status B2 2 Outputs/ 1 Flow Units Inputs 2'°`Flow Format 1 Full Scale 2 Damping Control 1 Display Flow 1 Totalizer Units 3 Time Constant 2 Display Counters 2'Totalizer Format 4 Cutoff Control 3 Display Value P 5*Cutoff`On'value 1 Pulse Value Units 6*Cutoff`Of value 2'°°Pulse Value Fmt 7 Display 1 Function I 8 Current Output I 2 Rev.Range Control 9°p'Pulse B1 3*Rev.Range Scale 1 Function P 9°p'Control/Status B1 4 I 0% 2 Pulse Type 3 Operation 10 P'Control/Status B2 5 1 100% 3 Pulse Control I I*Auto/Extern.Range 6 I Max 4*Pulse Width 12:Trip.Point 1,Low 7 I Error 5 Pulse Value 13 Trip.Point 1,High 14:Trip.Point 2,Low 15 Trip.Point 2,High 1 Diameter 2 Full Scale 3 GK Value 1 Test Range (M) 4 Field Frequency 4 Test 2 Hardware Info M) 5 Line Frequency 3 Sensor Limits 1 Upper Sensor Limit 6 Flow Direction 2 Sensor Min Span 1 Language 2 Flowmeter 3 Zero trim (M) 1 Text Volume 5 Installation 4 User Unit 2 Factor Volume 5 Application 3 Text Time 1 Flow 4 Factor Time 6 Hardware 2°pr Empty Pipe 6 Quit/Reset 1 Terminal B1 1 Hardware 2 Terminal B2 2 Tag 7 Set/Reset 3 Device Id 1 Counters 1 Stop/Resume (M) 4 Field Device Rev 2 Error List M 2 Reset Counters (M) Password(M) 5 Software Rev ( ) 8 HART 6 Hardware Rev Variables 7 Message 8 Descriptor 9 Date 10 Final asmbly num 11 PV Sensor serial num 12 Num response preams 13 Polling address Designations: °p'—Optional item,depends on device implementation:availability of Binary Terminals B 1/B2 and their assignment,etc.; N*—Availability of the item depends on the assignment made for some previous item(s):say,cutoff values become visible/editable only if`Cutoff Control'parameter is set to"Yes"; Local HC275 variable,that is not read/written to instrument; (M)—Method is invoked to retrieve/change data. KROHNE IFC090 45f40201 KROHNE KROHNE Messtechnik GmbH&Co.KG•Ludwig-Krohne-Str.5•D-47058 Duisburg 6/8 Tel.:0203-301 0•Fax:0203-301 389•e-mail:krohne@krohne.de Remote Operation Instructions IFC090 HART Attachment B IFC090 Menu Tree AMS ooFlow ooFlow,Percent Range ooPositive Totalizer ooNegative Totalizer ooTotalizers' Sum ooCurrent Output ooPulse Output°p` ooControl/Status B 1 Stateopt ooControl/Status B2 Stateopt Process Variables Status Scan Device Overview ----------------------------------- ooPrimary variable out of limits Diagnostics and Test ooNon-primary variable out of limits Calibrate ooPrimary variable analog output saturated ooPrimary variable analog output fixed Reset totalizers ooCold start Stop/resume totalizers ooConfiguration changed Set/reset password ooField device malfunction ----------------------------------- Audit Trail Fatal errors Drawing Notes... Help... ooAnalog Digital Converter fatal error I/O module fatal error ----------------------------------- ooDevice Block fatal error ooFatal error of Current Output Clear Offline Configuration ooDisplay module fatal error ooFatal error of Pulse Outputop` Compare Configurations ooFatal error of Control Input 1 opt Configuration Properties ooFatal error of Control Input 2°pr ooFatal error of Status Output lop` ooFatal error of Status Output 2°pr Data Errors Warnings Checksum error in Parameter EEPROM ooCurrent output overranged ooChecksum error in General Block ooPulse output overrangedop` ooChecksum error in Current Block ocCounter overflow ooChecksum error in Pulse/Frequency Block ooPower fail detected ooChecksum error in Control/Indication Block ooError in IMoCom configuration ocChecksum error in Display Block ooAnalog/digital converter overranged ocChecksum error in Communication Block ooEmpty pipeop` Designations: OP'-Optional variable,depends on device implementation:availability of Binary Terminals B 1/B2 and their assignment,etc.; E>— refer to the next page. KROHNE IFC090 45f40201 KROHNE Messtechnik GmbH&Co.KG•Ludwig-Krohne-Str.5•D-47058 Duisburg 7/8 KROHNE Tel.:0203-301 0•Fax:0203-301 389•e-mail:krohne@krohne.de Remote Operation Instructions IFC090 HART Attachment B (continued from the previous page) IFC090 Menu Tree AMS Loop test Designations: Test measuring range ' —Optional variable,depends on device implementation: ----------------------------- availability of Binary Terminals B 1/B2 and their assignment, Hardware information etc.; Quit/view errors Rd— Read-only variable; Local AMS variable,affects only AMS faceplates and configuration tabs and is not read/written from/to instrument. Zero trim Apply values ------------------------------- Calibration Management Process Variables Status Scan Device ----------------------------------- Basic Setup Sensor Process Input Diagnostics and Test ooHardware' ooPV Sensor serial num ooFlow Units Calibrate ooTag ooDiameter ooTotalizer Units ----------------------------------- -------------------------------- ooGK Value ooPulse Value Units Reset totalizers ooUpper Sensor Limit"' ooFlow Direction ooTime Constant Stop/resume totalizers ooSensor Minimum Span-' -------------------------------- -------------------------------- Set/reset password -------------------------------- ooUpper Sensor Limie' ooFlow format`" ----------------------------------- ooTime Constant ooSensor Minimum Span"' ooTotalizers'format" Audit Trail ooFlow Units -------------------------------- ooPulse Value format`" Drawing Notes... -------------------------------- ooApplication Help... ooFull Scale Value ooField Frequency ----------------------------------- ooFlow Min' ooLine Frequency Clear Offline Configuration ooDamping Control -------------------------------- Compare Configurations -------------------------------- ooADC firmware Id' Configuration Properties ooTerminal B1°pr ooI/O firmware Id' ooTerminal B2°pt coDisplay firmware Id" Analog Output Binary 1/0 Device ooFunction I ooTerminal B1 Function°pt ooModel' ooRev.Range Control ooTerminal B2 Function°pt ooManufacturer" ooRev.Range Scale -------------------------------- ooField device revision-' ooI 0% ooTrip.Point 1,Low ooHardware revision-' wI 100% ooTrip.Point 1,High ooSoftware revision-' ooI Max ooTrip.Point 2,Low ooWrite protect ooI Error ooTrip.Point 2,High -------------------------------- -------------------------------- ooAuto/External Range ooEmpty Pipe°pt ooAO Alarm type-' -------------------------------- -------------------------------- HART ooTerminal B 1°pt ooFunction Pop' wTa ooTerminal B20pt ooPulse Typeop` g -d -------------------------------- ooDevice Id ooPulse Control°p7 Next Volume ooFinal assembly num.00Pulse Width°pt Next ext Time ooPulse Value°pt ooDescriptor ooFactor Volume -------------------------------- ooFactor Time ooCutoff Control ooMessage -------------------------------- ooCufoff`On'value ooUniversal revisionR' ooCutoff`Off value ooNum request preamsRa ooNum response preams ooPolling address KROHNE IFC090 45f40201 KROHNE KROHNE Messtechnik GmbH&Co.KG Ludwig-Krohne-Str.5•D-47058 Duisburg 8/8 Tel.:0203-301 0•Fax:0203-301 389•e-mail:krohne@krohne.de