HomeMy WebLinkAboutAD_USB GDC IMOCOM Manual__en__110815_7311932200_R02 M USB ADAPTER PLUS - Quick Start Configuration tool for: • IFC 100/300 (with Pactware) • BATCHFLUX 5500 C (with BatchMon Plus) • IFC 010/090/ 110 and BATCHFLUX 5012 C/5015 C (with ImoMon Plus) ©KROHNE 08/2011-7311932200-QS USB_Adapter_Plus R02 en KROHNE CONTENTS USB ADAPTER 1 General description 3 2 Operation 4 2.1 I FC 100 ..............................................................................................................................4 2.2 I FC 300 .............................................................................................................................. 5 2.3 BATCHFLUX 5500 C.......................................................................................................... 6 2.4 Converters with ImoCom................................................................................................ 12 3 Notes 13 2 www.krohne.com 08/2011 -7311932200-QS USB_Adapter_Plus R02 en = ADAPTER PLUS t GENERAL DESCRIPTION The USB-Adapter Plus is an adapter to read/write all kind of data to many different converters. The following overview shows you which parts and software you need: Signal converter Cable Software IFC 100 and IFC 300 Standard cable dubox 2x3-pole> dubox Pactware+DTM +GDC 2x4-pole or IR interface cable drivers BATCHFLUX 5500 C Optional cable M12 5-pole> dubox 2x4- BatchMon Plus pole Optional T-connector Old ImoCom converters, eg Optional cable dubox 1x5-pole > 2x4- ImoMon Plus BATCH FLUX 5015, IFC 010 pole The scope of delivery includes the USB-Adapter Plus, the cable needed for IFC 100/300 and the printed documentation. Optionally you receive a set of connection cables/connectors for connection to BATCHFLUX 5500 and old ImoCom type converters. 08/2011-7311932200-QS USB_Adapter_PLus R02 en www.krohne.com 3 p OPERATION M = As described in the previous chapter,the USB-Adapter Plus can be used in three ways. Each way is described in a separate section. 2.1 IFC 100 The standard delivery includes all items you need to use it with an IFC 100 signal converter. 10 • OKROHNE LED1 _ USB-Adapter Plus LED2 Figure 2-1:Connection of adapter to the GDC bus of the IFC 100. 1) Connection room of IFC 100 2� Cable 20-pole>2x4-pole Z3 USB-Adapter Plus Needed software: • GDC driver • 1 FC 100 HART DTM • Pactware configuration tool a /NFORMA T/ON! 1 All relevant tools are on the CD and on the website of the manufacturer. Connect the USB connector to your PC, start the relevant program and follow the instructions given on the display. Refer to the documentation of the signal converter for a description of the menu. 4 www.krohne.com 08/2011 -7311932200-IDS USB_Adapter_Plus R02 en = ADAPTER PLUS OPERATION 2.2 1 FC 300 The standard delivery includes all items you need to use it with an IFC 300 signal converter. with GDC connection cable aT 0�� 0 0 KROXNE LED USB-Adapter Plus LED: Figure 2-2:Connection of adapter to the GDC bus of the IFC 300. J) Connection room of IFC 300 (2) Cable 2x3-pole>2x4-pole Z USB-Adapter Plus with IR interface cable F-1 O O KROHNEE 1 USB-Adapt : Figure 2-3:Connection of adapter to the IR interface of the IFC 300. J) Display of IFC 300 IR Interface cable USB-Adapter Plus Needed software: • GDC driver • IFC 300 HART DTM • Pactware configuration tool a /NFORMA T/ON! 1 All relevant tools are on the CD and on the website of the manufacturer. Connect the USB connector to your PC, start the relevant program and follow the instructions given on the display. Refer to the documentation of the signal converter for a description of the menu. 08/2011-7311932200-OS USB_Adapter_Plus R02 en www.krohne.com 5 OPERATION = - 2.3 BATCHFLUX 5500 C A CAUTION! The T-connector and the cable Ml25-pole>2x4-pole areavailable as an optional package. 10 02 03 FJ 0-1041 if KROHNE 24 V 05 KRONNE LED USB-Adapter Plus LED2� Figure 2-4:Connection of adapter to the BATCHFLUX 5500 C. 1� 24 V supply(to be provided by customer) © T-connector(optional) (3 M12 5-pole connector 4� USB-Adapter Plus(standard) © Cable M12 5-pole>2x4-pole(optional) Needed software: • BatchMon Plus 6 www.krohne.com 08/2011-7311932200-QS USB_Adapter_Plus R02 en USB ADAPTER PLUS OPERATION p a /NFORMA T/ON! 1 All relevant tools are on the website of the manufacturer. Installation procedure: • Do NOT connect the USB adapter yet. • Install the software KROHNE BatchMon Setup Version 2.0.x.x. Ignore any error messages about Windows certificates. • Connect the USB cable to the computer. The wizard "New hardware found" starts. - Choose "Not now", click 1x on "Next". - Screen "Hardware" opens, click 2x on "Continue". - If hardware is detected, click on "Finish". Message shows "Hardware can be used". • Start the BatchMon Plus program once. Close the program and start it again. In the menu, the function "On-line processing" is now enabled. a /NFORMA T/ON! 1 Next time,just connect the USB-Adapter Plus and start the program. The menu of the BATCHFLUX 5500 C is given on the next pages. 08/2011 -7311932200-OS USB_Adapter_Plus R02 en www.krohne.com 7 OPERATION USB ADAPTER Menu Cl: Process input IN o. Function/subfunction Settings/descriptions C1.1 Calibration C1.1 Calibration C1.1.1 Zero calibration Measured zero point(m/s). Use the"calibration" button to calculate a new zero.Calibration procedure takes 30 seconds. C1.1.2 Size entry selection Value (mm),Table(mm, inch) For"Value": manual input of flow meter size in box 1.1.3. For"Table":choose from pull down menu in box 1.1.4. C1.1.5 GK selection GK,GKL For"GK":value is shown in box 1.1.6. For"GKL":value is shown in box 1.1.7 C1.1.8 Coil resistance 10...220 S2 Configured, can be changed. C1.1.9 Field frequency 1/6...2* line frequency Choose from pull down menu. 1.1.10 Select settling Standard (predefined), Manual 1.1.11 Settling time 0,001...0,25(s) Manual input 1.1.12 Line frequency 50 or 60 Hz 1.1.13 Measurement conductivity Off, On Off: Default 1.1.14 Number values 0...10 Number of measurements taken to calculate the average conductivity(if 1.1.13 is switched on). 8 www.krohne.com 08/2011-7311932200-QS USB_Adapter_PLus R02 en = ADAPTER PLUS OPERATION C1.2 Filter C1.2 Filter C1.2.1 Min. limitation -100...-0,001 (m/s) The output freezes at this value. C1.2.2 Max. limitation 0,001...100 (m/s) The output freezes at this value. C1.2.3 Flow direction Normal direction (default), Reverse direction C1.2.4 Time constant 0...100 (s) Manual input C1.2.5 Low flow cut off threshold 0...10 (m/s) Manual input C1.2.6 Low flow cut off 0...10 (m/s) hysteresis Manual input C1.3 Information C1.3 Information Menu C2: Inputs/outputs (1/0's) No. Function/subf unction Settings/descriptions C2.1 Hardware C2.1.0 Hardware Frequency output, Pulse output C2.1.1 Terminals D Program frequency output in submenu 2.2.0.1. Program pulse output in submenu 2.2.0.2. C2.2 Frequency output (if selected in 2.1.0 "hardware") C2.2.1 Pulse shape Symmetric, Fixed,Automatic(default) C2.2.2 Pulse width 5E-5...2(s) C2.2.3 100%pulse rate 0,01...10000(Hz) C2.2.4 Range min. -1 E+30 +1 E+30(m3/S) Manual input. C2.2.5 Range max. -1 E+30 +1 E+30(m3/s) Manual input. C2.2.6 Polarity Both polarity, Positive polarity(default), Negative polarity,Absolute polarity C2.2.7 Limitation min. -1 E+30 +1 E+30(%) C2.2.8 Limitation max. -1 E+30 +1 E+30 1%) C2.2.9 Low flow cut off threshold 0...20 (%) Manual input. C2.2.10 Low flow cut off 0...20 N hysteresis Manual input. 2.2.11 Time constant 0...100 (s) C2.2.12 Invert signal Off(default), On 08/2011-7311932200-QS USB_Adapter_PLus R02 en www.krohne.com 9 OPERATION USB ADAPTER [NO-- Function/subfunction Settings/descriptions C2.2 Pulse output (if selected in 2.1.0 "hardware") C2.2.1 Pulse shape Symmetric, Fixed,Automatic(default) C2.2.2 Pulse width 5E-5...2(s) C2.2.6 Polarity Both polarity, Positive polarity(default), Negative polarity,Absolute polarity C2.2.11 Time constant 0...100 (s) C2.2.12 Invert signal Off(default), On C2.2.13 Max. pulse rate 0,01...10000(Hz) C2.2.14 Value per pulse -1 E+30 +1 E+30(m3) C2.2.15 Low flow cut off threshold -1 E+30 +1 E+30(m3/s) Manual input C2.2.16 Low flow cut off -1 E+30 +1 E+30(m3/s) hysteresis Manual input Menu C3: Device No. Function/subfunction Settings/descriptions C3.1 Units C3.1.1 Volume flow l/s, I./min, 1/h, m3/s, m3/min, m3/h,ft3/s,ft3/min,ft3/h, gal/s, gal/min,gal/h, lG/min, lG/h,free unit When you choose"free unit"two additional boxes will appear: box 3.1.2(text free unit)and box 3.1.3 (m3/s*factor).With this factor the BATCHFLUX will calculate the right value for your free unit. C3.1.4 Volume ml, 1, hl, m3, in3,ft3,yd3,gal, 1G,free unit When you choose free unit two additional boxes will appear: box 3.1.5 (text free unit)and box 3.1.6 (m3*factor).With this factor the BATCHFLUX will calculate the right value for your free unit. 10 www.krohne.com 08/2011-7311932200-QS USB_Adapter_PLus R02 en USIB ADAPTER PLUS OPERATION Menu C4: Service No. Function/subfunction C4.1 Oscillograph Horizontal axis is the quantity of collected values. Information is only stored as RAM. If the adapter is not connected,the only function for the oscilloscope is available. Offline processing of.DAT file: Calculate the volume of filling by using the mouse.Click one time at the start of the batch,then drag the mouse to the end and you can read the volume. C4.2 Sensor values C4.2.1 Flow velocity C4.2.2 DC voltage electrode 2 C4.2.3 DC voltage electrode 3 C4.2.4 Electronic temperature C4.2.5 Field current setting time C4.2.6 Field current resistance C4.2.7 Status sensor C4.2.8 Status starting phase C4.2.9 Status warnings C4.2.10 Status fatal C4.2.11 Status field current C4.2.12 Coil temperature C4.2.13 Conductivity 08/2011-7311932200-QS USB_Adapter_PLus R02 en www.krohne.com 11 19 OPERATION USB ADAPTER PLUS 2.4 Converters with ImoCorn Old converters can be used if they have an ImoCom connector on board. Some possibilities are shown below. 04'M L=j 0 0 CD 0 sense :::nm Mm o LED 1 USB-Adapter pjUS LED2 Figure 2-5: (D BATCHFLUX 5012 C 5015 C flowmeter (2) IFC 010 signal converter (I IFC 090 signal converter (4) IFC 110 signal converter USB-Adapter Plus Optional cable(I x5-pote connector>2x4-pole connector) 02ACAUTION! * Please note that ":net Framework 2.0"is installed before installation[part of Windows XP service pack 21. 0 The 1,moCom cable 1x5-pole connector>2x.14-pole connector is available as an optional package. Needed software: 0 ImoMon Plus INFORMA TION! All relevant tools are on the CD and on the website of the manufacturer. Connect the USS connector to your PC, start the relevant program and follow the instructions given on the display. 12 www.krohne.com 08/2011 -7311932200-OS USB-Adapter-Plus R02 en = ADAPTER PLUS NOTES A 08/2011-7311932200-QS USB_Adapter_PLus R02 en www.krohne.com 13 NOTES USB ADAPTER PLUS 14 www.krohne.com 08/2011-7311932200-QS USB_Adapter_PLus R02 en = ADAPTER PLUS NOTES A 08/2011-7311932200-QS USB_Adapter_PLus R02 en www.krohne.com 15 r� r . rti,y • •• M• • • •• AW to ri KROHNE product overview • Electromagnetic flowmeters • Variable area flowmeters • Ultrasonic flowmeters • Mass flowmeters L • Vortex flowmeters 3 • Flow controllers 0 • Level meters • Temperature meters N • Pressure meters N • Analysis products 0 • Measuring systems for the oil and gas industry a v • Measuring systems for sea-going tankers Cn a m 0 Head Office KROHNE Messtechnik GmbH N Ludwig-Krohne-Str. 5 D-47058 Duisburg (Germany) 0 Tel.:+49 (0)203 301 0 0 Fax:+49 (0)203 301 10389 Z infofdkrohne.de & The current list of all KROHNE contacts and addresses can be found at: KROHNE Y o www.krohne.com