Loading...
HomeMy WebLinkAboutAP_OPTIFLUX 1000-OPTIFLUX 2000-OPTIFLUX 4000-OPTIFLUX 5000-OPTIFLUX 6000-IFC 300_C+F_en_CSA_101124__ s� CSA INTERNATIONAL Certificate of Com lian p ce Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 Issued to: KROHNE,Inc. 7 Dearborn Rd Peabody,MA 01960 USA Attention: Rick Loiselle The products listed below are eligible to bear the CSA Mark shown ELLWoL4-d,Fo-o- ® Issued by: Edward Foo, C.E.T. PRODUCTS CLASS 2258 03 -PROCESS CONTROL EQUIPMENT-Intrinsically Safe and Non- Incendive Systems-For Hazardous Locations Class I,Division 2, Groups A,B,C and D; Class II,Division 2,Groups F and G: • OPTIFLUX 1000-DIV2 series Primary Head.Model VN174abcdefghijklmn. Operating ambient-50°C to 40°C; Temperature Code T6. Enclosure type as specified in the detail below. Where: a=Nominal Diameter: 5, 6, 8,B, C,E,F, or H. b=Nominal Pressure: A, or B. c=Approval: C. d=System design: 1,2,4, 6,A,or C. e=Converter Model: C, or D. f=Mounting Material: (any alphanumeric digit). g=Grounding Ring Material: (any alphanumeric digit). DQD 507 Rev.2009-09-01 Page:1 SR CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 h=Electrodes: 0. i=Protection Class: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. j =Cable: 2(Type 6P),or any other alphanumeric digit(Enclosure types other than 6P). k=Cable Length: (any alphanumeric digit). 1=Calibration: (any alphanumeric digit). in=Construction Requirements: (any alphanumeric digit). n=QA/QC Requirements: (any alphanumeric digit). Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2,IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. 2) I.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. • OPTIFLUX 2000-DIV2 series Primary Head.Model VN144abcdefghijklmnop. Operating ambient-50°C to 40°C; Temperature Code T6. Enclosure type as specified in the detail below. Where: a=Nominal Diameter: 4, 5, 6,7, 8,A,B,C, or D. b=Nominal Pressure: 3,4, 5,A, or B. c=Approval: C. d=Cable Connection: 1,2,4, 6,A, or C. e=Converter Model: C, or D. DQD 507 Rev.2009-09-01 Page:2 SR CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 f=Lining: (any alphanumeric digit). g=Electrode: 1,3, or 6. h=Construction of Electrodes: 1. i=Housing/Flange material: 1, 3,or 4. j =Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. k=Cable: 2 (Type 6P), or any other alphanumeric digit(Enclosure types other than 6P). 1=Cable Length: (any alphanumeric digit). m=Calibration: (any alphanumeric digit). n=G-P Ring/Material: (any alphanumeric digit). o=Special: 0. p=Module/labeled: 1 Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2,IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. 2) I.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. • OPTIFLUX 2000-DIV2 series Primary Head. Model VN154abcdefghijklmnop. Operating ambient-50°C to 40°C;Temperature Code T6. Enclosure type as specified in the detail below. Where: a=Nominal Diameter: E,F,G,H,K,L,M,or N. b=Nominal Pressure: 2, 3,4, 5,A, or B. c=Approval: C. DQD 507 Rev.2009-09-01 Page:3 SP CSA INTERNATIONAL ---------------------- Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 d=Cable Connection: 1,2,4, 6,A, or C. e=Converter Model: C, or D. f=Lining: (any alphanumeric digit). g=Electrode: 1, 3, or 6. h=Construction of Electrodes: 1. i=Housing/Flange material: 1, 3, or 4. j =Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. k=Cable: 2 (Type 6P), or any other alphanumeric digit(Enclosure types other than 6P). 1=Cable Length: (any alphanumeric digit). m=Calibration: (any alphanumeric digit). n=G-P Ring/Material: (any alphanumeric digit). o=Special: 0. p=Module/labeled: 1 Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. 2) I.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. • OPTIFLUX 2000-DIV2 series Primary Head. Model VN I 64abcdefghijklmnop. Operating ambient-50°C to 40°C; Temperature Code T6. Enclosure type as specified in the detail below. DQD 507 Rev.2009-09-01 Page:4 SR CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 Where: a=Nominal Diameter:Up to a maximum of 120 inches at 276 PSI. b=Nominal Pressure: 1,2, or A. c=Approval: C. d=Cable Connection: 1,2,4, 6,A, or C. e=Converter Model: C, or D. f=Lining: (any alphanumeric digit). g=Electrode: 1,3, or 6. h=Construction of Electrodes: 1. i=Housing/Flange material: 1, 3,or 4. j =Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. k=Cable: 2 (Type 6P), or any other alphanumeric digit(Enclosure types other than 6P). 1=Cable Length: (any alphanumeric digit). m=Calibration: (any alphanumeric digit). n=G-P Ring/Material: (any alphanumeric digit). o=Special: 0. p=Module/labeled: 1 Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. DQD 507 Rev.2009-09-01 Page:5 SR CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 • OPTIFLUX 4000-DIV2 series Primary Head. Model VN024abcdefghijklmnop. Operating ambient-50°C to 40°C; Temperature Code T6. Enclosure type as specified in the detail below. Where: a=Nominal Diameter: 1,2, 3, 5, 6, or 7. b=Nominal Pressure: A, or B. c=Approval: C. d=Cable Connection: 1,2,4, or A. e=Converter Model: C, or D. f=Lining: (any alphanumeric digit). g=Electrode: 1,2, 3,4, 5, 6, 7,G,or U. h=Construction of Electrodes: 1. i=Housing/Flange material: 1, 3,4,E, G,K,M, or N. j =Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. k=Cable: 2 (Type 6P), or any other alphanumeric digit(Enclosure types other than 6P). 1=Cable Length: (any alphanumeric digit). m=Calibration: (any alphanumeric digit). n=G-P Ring/Material: (any alphanumeric digit). o=Special: 0. p=Module/labeled: 1 Notes: DQD 507 Rev.2009-09-01 Page:6 SR CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. • OPTIFLUX 4000-DIV2 series Primary Head.Model VN034abcdefghijklmnop. Operating ambient-50°C to 40°C; Temperature Code T6. Enclosure type as specified in the detail below. Where: a=Nominal Diameter: 1,2, 3,4, 5, 6, 7, 8,A,B, C, or D. b=Nominal Pressure: 3,4, 5,A,B,D or E. c=Approval: C. d=Cable Connection: 1, 2,4,6,A,or C. e=Converter Model: C, or D. f=Lining: (any alphanumeric digit). g=Electrode: 1,2, 3,4, 5, 6, 7,G,or U. h=Construction of Electrodes: 1. i=Housing/Flange material: 1,2, 3,4,A,B, C,D,K,L,M, or N. j =Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. k=Cable: 2 (Type 6P), or any other alphanumeric digit(Enclosure types other than 6P). 1=Cable Length: (any alphanumeric digit). in=Calibration: (any alphanumeric digit). n=G-P Ring/Material: (any alphanumeric digit). DQD 507 Rev.2009-09-01 Page:7 SR CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 o=Special: 0. p=Module/labeled: 1 Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. • OPTIFLUX 4000-DIV2 series Primary Head.Model VN044abcdefghijklmnop. Operating ambient-50°C to 40°C;Temperature Code T6. Enclosure type as specified in the detail below. Where: a=Nominal Diameter: E,F, G,H,K, L,M, or N. b=Nominal Pressure: 2, 3,4, 5,A,or B. c=Approval: C. d=Cable Connection: 1,2,4, 6, A,or C. e=Converter Model: C, or D. f=Lining: (any alphanumeric digit). g=Electrode: 1, 3,4, 5, 6, 7, G,M,R, or U. h=Construction of Electrodes: 1. i=Housing/Flange material: 1, 3,4,A, C,D,K,M, or N. j =Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. DQD 507 Rev.2009-09-01 Page:8 SR CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 k=Cable: 2 (Type 6P), or any other alphanumeric digit(Enclosure types other than 6P). 1=Cable Length: (any alphanumeric digit). m=Calibration: (any alphanumeric digit). n=G-P Ring/Material: (any alphanumeric digit). o=Special: 0. p=Module/labeled: 1 Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. • OPTIFLUX 4000-DIV2 series Primary Head.Model VN054abcdefghijklmnop. Operating ambient-50°C to 40°C;Temperature Code T6. Enclosure type as specified in the detail below. Where: a=Nominal Diameter: 28 inches,up to a maximum of 120 inches. b=Nominal Pressure: 1,2, or A. c=Approval: C. d=Cable Connection: 1,2,4, 6,A, or C. e=Converter Model: C, or D. f=Lining: (any alphanumeric digit). g=Electrode: 1, 3,4, 5, 6, 7, G,M, R, or U. h=Construction of Electrodes: 1. DQD 507 Rev.2009-09-01 Page:9 SR CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 i=Housing/Flange material: 1, 3,4,A,C,D,K,M,or N. j =Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. k=Cable: 2 (Type 6P), or any other alphanumeric digit(Enclosure types other than 6P). 1=Cable Length: (any alphanumeric digit). in=Calibration: (any alphanumeric digit). n=G-P Ring/Material: (any alphanumeric digit). o=Special: 0. p=Module/labeled: 1 Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. • OPTIFLUX 5000-DIV2 series Primary Head.Model VN184abcdefghijklmn. Operating ambient-50°C to 40°C;Temperature Code T6.Enclosure type as specified in the detail below. Where: a=Nominal Diameter: 1,2, 3, 5, 6, 8,B, C, E, or F. b=Nominal Pressure: 3,4, 5,A, or B. c=Approval: C. d=Cable Connection: 1,2,4, 6,A, or C. DQD 507 Rev.2009-09-01 Page:10 SR CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 e=Converter Model: C, or D. f=Mounting Material: (any alphanumeric digit). g=G-Ring Material/Gasket Material: (any alphanumeric digit). h=Electrode: 0. i=Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. j =Cable: 2(Type 6P),or any other alphanumeric digit(Enclosure types other than 6P). k=Cable Length: (any alphanumeric digit). 1=Calibration: (any alphanumeric digit). in=Special: 0. n=Module/labeled: 1 Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2,IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DIV2,IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. • OPTIFLUX 5000-DIV2 VN244abcdefghijklmnop Primary Head. (Flange Version) Operating ambient-50°C to 40°C; Temperature Code T6. Enclosure type as specified in the detail below. Where: a=Nominal diameter: 2,4,6,7,A,B. b=Nominal pressure: 3, 5 or A. c=Approval: C. DQD 507 Rev.2009-09-01 Page:11 SP CSA INTERNATIONAL ---------------------- Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 d=Cable connection: 1, 2,4, 6,A or C. e=Converter model: C or D. f =Lining: not safety relevant. g=Electrode: 0. h=Construction of electrodes: 1. i =Housing/flange material: 0 j =Protection class/dimension: 0 or 2. k=Cable: 2 (Type 6P); Other—Not Safety Relevant. 1 =Cable length: not safety relevant. m=Calibration: not safety relevant. n=G-P-Ring/Material: not safety relevant. o=Special: 0. p=Module/labeled: 0 or 1. Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. 2) I.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. • OPTIFLUX 6000-DIV2 series Primary Head.Model VN224abcdefghijklmn. Operating ambient-50°C to 40°C; Temperature Code T6. Enclosure type as specified in the detail below. Where: a=Nominal Diameter: 1,2, 3, 5, or 6. DQD 507 Rev.2009-09-01 Page:12 SR CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 b=Connection: 5, 6,A,B,H,K,L,M,N,P, S, T,or U. c=Approval: C. d=Cable Connection: 1,2,4, 6,A, or C. e=Converter Model: C, or D. f=Mounting Material: (any alphanumeric digit). g=G-Ring Material/Gasket Material: (any alphanumeric digit). h=Electrodes: 1, 3,4, 5, 6, 7,or A. i=Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. j =Cable: 2(Type 6P),or any other alphanumeric digit(Enclosure types other than 6P). k=Cable Length: (any alphanumeric digit). 1=Calibration: (any alphanumeric digit). m=Special: 0. n=Module/labeled: 1 Notes: 3) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2,IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. 4) I.S.Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. • Primary Head Model IFS 4000 F-DIV2 series,magnetic flow meter sensor,rated 40 Vdc, 125mA. Install per Dwgs 8.30702.63 and 8.30702.64.Temperature Code T6,Ta=-50°C to 40°C. Notes: DQD 507 Rev.2009-09-01 Page:13 SP CSA INTERNATIONAL ---------------------- Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 1) Primary Head,Model IFS 4000 F-DIV2 must only be used with Certified remote signal converter models IFC 300 F-DIV2,IFC 300 F(/i)- DIV2 or IFC 090-F DIV2. 2) I.S. Electrodes when used with remote signal converters,models IFC 300 F-DIV2,IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 3) Internal order code known as type V303. • Primary Head Model IFS 5000 F-DIV2 series,magnetic flow meter sensor,rated 40 Vdc, 125mA. Install per Dwgs 8.30702.63 and 8.30702.64. Temperature Code T6,Ta=-50°C to 40°C. Notes: 1) Primary Head Model IFS 5000 F-DIV2 must only be used with Certified remote signal converter, models IFC 300 F-DIV2,IFC 300 F(/i)-DIV2 or IFC 090. 2) I.S. Electrodes when used with remote signal converters,models IFC 300 F-DIV2,IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 3) Internal order code known as type V304. • IFC300 series Signal Converter. Model a VN304bcdefghijklmno. Rated 100-230Vac,22VA, 50-60 Hz and/or 12-24Vdc/24V ac/dc, 12W. Operating ambient-50°C to 40°C; Temperature Code T6. Enclosure type 4X,Type 6. Where: a=Input/Output: F(/i)-DIV2 indicates associated nonincendive field wiring and I.S. entity parameters,per control drawing 8.30702.65. F-DIV2 indicates normally nonarcing field wiring for use with Class I Div 2 wiring methods, b=Type: 4, or H. c=Power Supply: 1,4, or A. DQD 507 Rev.2009-09-01 Page:14 SR CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 d=Approval: C. e=Cable Connection: 4,or 6. f=Instruction/Programming Language: (any alphanumeric digit). g=Custody Transfer: 0. h=Process Diagnostics: (any alphanumeric digit). i=Converter Housing: 1 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 4X and Type 6. j =Labeled: 1. k=Communications Slot I01 Selection: 1,2, 3,4, 6,7, 8,B, C,D,E,F, G, or H. 1=First IO Module(102/A): 0, 1,2, 8,A,B, C,E,F, G,H, or K. m=Second IO Module(IO2/13): 0, 8,A,B, C,E,F, G,H, or K. n=Reference Method: 0,or 1 o=Tagplate: (any alphanumeric digit). Notes: 1) OPTIFLUX IFC300 F signal converter electronics must be installed in explosionproof MH300C housing, and used with OPTIFLUX,IFS 4000E-DIV2 or IFS 5000E-DIV2 Primary Head. 2) Install per manufacturers drawings 8.30702.63 or 8.30702.64. • OPTIFLUX a300 C-DIV2 Flowmeter. Rated 100-230Vac,22VA, 50-60 Hz and/or 12-24Vdc/24V ac/dc, 12W. Operating ambient-50°C to 40°C; Temperature Code T6. Enclosure type 4X, Type 6. Where: a=Type: 1,2, 4, 5, or 6. DQD 507 Rev.2009-09-01 Page:15 SP CSA INTERNATIONAL ---------------------- Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2372993 Date Issued: November 24,2010 Consists of the OPTIFLUX a000-DIV2 series Primary Head(Where: a=Type: 1, 2, 4, 5, or 6), and the IFC300 F-DIV2 VN304bcdefghijklmno Signal Converter. • OPTIFLUX a300 C/i-DIV2 Flowmeter. Rated 100-230Vac, 22VA, 50-60 Hz and/or 12-24Vdc/24V ac/dc, 12W. Operating ambient-50°C to 40°C; Temperature Code T6. Enclosure type 4X, Type 6. Where: a=Type: 1,2,4, 5, or 6. Consists of the OPTIFLUX a000-DIV2 series Primary Head(Where: a=Type: 1,2,4, 5, or 6), and the IFC300 F(/i)-DIV2 VN304bcdefghijklmno Signal Converter. Note: 1) Nonincendive Field Wiring and Intrinsically Safe Entity Parameters when installed per manufacturers Control Drawings and drawing 8.30702.65. APPLICABLE REQUIREMENTS CAN/CSA Standard C22.2 No. 0-M91 (Reaffirmed 2001)-General Requirements-Canadian Electrical Code,Part II CAN/CSA Standard C22.2 No. 94-M94(Reaffirmed 2001)-Special Purpose Enclosures CSA Standard C22.2 No. 142-M1987(Reaffirmed 2000)-Process Control Equipment CSA Standard C22.2 No.25-1966(Reaffirmed 2000)-Enclosures for Use in Class II Groups E,F,and G Hazardous Locations CSA Standard C22.2 No.30-M1986(Reaffirmed 2003)-Explosion-Proof Enclosures for Use in Class I Hazardous Locations CAN/CSA Standard C22.2 No. 157-92(Including update No.2,June,2003)-Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations. CSA Standard C22.2 No.213-M1987(Reaffirmed 2008)-Non-incendive Electrical Equipment for Use in Class I,Division 2 Hazardous Locations DQD 507 Rev.2009-09-01 Page:16