HomeMy WebLinkAboutAP_OPTIFLUX 1000-OPTIFLUX 2000-OPTIFLUX 4000-OPTIFLUX 5000-OPTIFLUX 6000-IFC 300_F_en_CSA DIV2_100514__ CSA INTERNATIONAL f � F Certificate of Compliance Certificate: 1665151 (LR 105802) Master Contract: 162767 F F Project: 2300463 Date Issued: 2010/05/14 E Issued to: KROHNE,Inc. 7 Dearborn Rd Peabody,MA 01960 USA Attention: Rick Loiselle [ The products listed below are eligible to bear the CSA Mark shown I £cdwa,rcLFaa; C.E.T. ® Issued by: Edward Foo,C.E.T. C$ PRODUCTS CLASS 2258 03 -PROCESS CONTROL EQUIPMENT-Intrinsically Safe and Non- Incendive Systems-For Hazardous Locations Class I,Division 2,Groups A,B,C and D;Class II,Division 2,Groups F and G: I • OPTIFLUX 1000-DIV2 series Primary Head.Model VN174abedefghijklmn. Operating ambient-50°C to 40°C;Temperature Code T6.Enclosure type as specified in the detail below. I Where: a=Nominal Diameter: 5,6, 8,B,C,E,F,or H. b=Nominal Pressure:A, or B. c=Approval:C. d=System design: 1,2,4,6,A, or C. e=Converter Model: C,or D. f=Mounting Material: (any alphanumeric digit). g=Grounding Ring Material:(any alphanumeric digit). (1 DQD 507 Rev.2009-09-01 [ ✓�y.an-., CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2300463 Date Issued: 2010/05/14 h=Electrodes:0. i=Protection Class: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. Cable:2(Type 6P or an other alphanumeric dirt Enclosure es other than 6P j= ( Yp )� Y p g• ( types )• k=Cable Length:(any alphanumeric digit). 1=Calibration:(any alphanumeric digit). F F in=Construction Requirements:(any alphanumeric digit). [ n=QA/QC Requirements:(any alphanumeric digit). F F F Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. [ F e • OPTIFLUX 2000-DIV2 series F Primary mnop.Head.Model VN144abcdefghijkl � Operating ambient-50°C to 40°C;Temperature Code T6.Enclosure type as specified in the detail below. Where: a=Nominal Diameter:4, 5,6,7,8,A,B,C,or D. f b=Nominal Pressure:3,4,5,A,or B. E c=Approval: C. d=Cable Connection: 1,2,4,6,A, or C. e=Converter Model:C,or D. DQD 507 Rev.2009-09-01 11400 0 ,,X. CSA INTERNATIONAL E E I Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2300463 Date Issued: 2010/05/14 f=Lining: (any alphanumeric digit). f g=Electrode: 1, 3,or 6. E F h=Construction of Electrodes: 1. i i=Housing/Flange material: 1,3,or 4. j =Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. i 2 indicates stainless steel enclosure,rated Type 6P. k=Cable:2(Type 6P),or any other alphanumeric digit(Enclosure types other than 6P). F 1=Cable Length:(any alphanumeric digit). in=Calibration:(any alphanumeric digit). n=G-P Ring/Material: (any alphanumeric digit). F o=Special:0. p=Module/labeled: 1 I F pF E Notes: i 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DIV2,IFC 300 F(/i)-DIV?or IFC 090-F DIV2 signal E converters. • OPTIFLUX 2000-DIV2 series Primary Head.Model VN154abcdefghijklmnop. Operating ambient-50°C to 40°C;Temperature Code T6.Enclosure type as specified in the detail below. i i Where: a=Nominal Diameter: E,F, G,H,K,L,M,or N. b=Nominal Pressure: 2,3,4,5,A,or B. c=Approval: C. i F DQD 507 Rev.2009-09-01 OSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2300463 Date Issued: 2010/05/14 d=Cable Connection: 1,2,4,6,A,or C. e=Converter Model:C,or D. f=Lining: (any alphanumeric digit). g=Electrode: 1,3,or 6. h=Construction of Electrodes: 1. i=Housing/Flange material: 1,3, or 4. j =Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. k=Cable:2(Type 6P),or any other alphanumeric digit(Enclosure types other than 6P). 1=Cable Length:(any alphanumeric digit). in=Calibration:(any alphanumeric digit). n=G-P Ring/Material: (any alphanumeric digit). o=Special:0. p=Module/labeled: 1 Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or lFC 090-F DIV2 signal converters. • OPTIFLUX 2000-DIV2 series Primary Head.Model VN164abcdefghijklmnop. Operating ambient-50°C to 40°C;Temperature Code T6.Enclosure type as specified in the detail below. DQD 507 Rev.2009-09-01 CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2300463 Date Issued: 2010/05/14 Where: a=Nominal Diameter:Up to a maximum of 120 inches at 276 PSI. b=Nominal Pressure: 1,2,or A. c=Approval: C. d=Cable Connection: 1,2,4,6,A,or C. e=Converter Model: C,or D. f=Lining: (any alphanumeric digit). g=Electrode: 1,3,or 6. h=Construction of Electrodes: 1. i=Housing/Flange material: 1,3,or 4. j =Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. k=Cable:2(Type 6P),or any other alphanumeric digit(Enclosure types other than 6P). 1=Cable Length:(any alphanumeric digit). m=Calibration:(any alphanumeric digit). n=G-P Ring/Material: (any alphanumeric digit). o=Special:0. p=Module/labeled: 1 Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. DQD 507 Rev.2009-09-01 CSA INTERNATIONAL ------------------------- f Certificate: 1665151 (LR 105802) Master Contract: 162767 I Project: 2300463 Date Issued: 2010/05/14 • OPTIFLUX 4000-DIV2 series Primary Head.Model VN024abcdefghijklmnop. Operating ambient-50°C to 40°C;Temperature Code T6.Enclosure type as specified in the detail below. F E Where. a=Nominal Diameter: 1,2,3,5,6,or 7. b=Nominal Pressure:A,or B. c=Approval: C. d=Cable Connection: 1,2,4,or A. e=Converter Model: C,or D. f=Lining: (any alphanumeric digit). g=Electrode: 1,2,3,4, 5,6,7,G,or U. h=Construction of Electrodes: 1. I } i=Housing/Flange material: 1,3,4,E,G,K,M,or N. j =Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. k=Cable:2(Type 6P),or any other alphanumeric digit(Enclosure types other than 6P). 1=Cable Length:(any alphanumeric digit). in=Calibration: (any alphanumeric digit). n=G-P Ring/Material: (any alphanumeric digit). o=Special: 0. I p=Module/labeled: 1 I Notes: 1 E E E F f E DQD 507 Rev.2009-09-01 CSA INTERNATIONAL f E Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2300463 Date Issued: 2010/05/14 E[[[€F E 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. • OPTIFLUX 4000-DIV2 series Primary Head.Model VN034abcdefghijklmnop. Operating ambient-50°C to 40°C;Temperature Code T6.Enclosure type as specified in the detail below. Where: a=Nominal Diameter: 1,2, 3,4,5,6,7, 8,A,B,C,or D. F b=Nominal Pressure: 3,4,5,A,B,D or E. c=Approval: C. d=Cable Connection: 1,2,4,6,A, or C. E e=Converter Model: C,or D. f=Lining: (any alphanumeric digit). g=Electrode: 1,2,3,4,5,6,7,G,or U. h=Construction of Electrodes: 1. i=Housing/Flange material: 1,2,3,4,A,B,C,D,K,L,M,or N. j =Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. k=Cable:2(Type 6P), or any other alphanumeric digit(Enclosure types other than 6P). 1=Cable Length:(any alphanumeric digit). F in=Calibration:(any alphanumeric digit). F n=G-P Ring/Material: (any alphanumeric digit). DQD 507 Rev.2009-09-01 �m CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2300463 Date Issued: 2010/05/14 o=Special: 0. p=Module/labeled: 1 Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. • OPTIFLUX 4000-DIV2 series Primary Head.Model VN044abcdefghijkhnnop. Operating ambient-50°C to 40°C;Temperature Code T6.Enclosure type as specified in the detail below. Where: a=Nominal Diameter:E,F,G,H,K,L,M,or N. b=Nominal Pressure:2,3,4,5,A,or B. a E c=Approval: C. d=Cable Connection: 1,2,4,6,A,or C. e=Converter Model:C,or D. f=Lining: (any alphanumeric digit). g=Electrode: 1,3,4, 5, 6, 7,G,M,R,or U. h=Construction of Electrodes: 1. i=Housing/Flange material: 1,3,4,A,C,D,K,M,or N. j =Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. DQD 507 Rev.2009-09-01 CSA INTERNATIONAL -------------------------- Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 23300463 Date Issued: 2010/05/14 k=Cable:2(Type 6P),or any other alphanumeric digit(Enclosure types other than 6P). 1=Cable Length:(any alphanumeric digit). in=Calibration:(any alphanumeric digit). n=G-P Ring Material: (any alphanumeric digit). o=Special: 0. p=Module/labeled: 1 Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. • OPTIFLUX 4000-DIV2 series Primary Head.Model VN054abcdefghijkhnnop. Operating ambient-50°C to 40°C;Temperature Code T6.Enclosure type as specified in the detail below. Where: a=Nominal Diameter:28 inches,up to a maximum of 120 inches. b=Nominal Pressure: 1,2,or A. c=Approval:C. d=Cable Connection: 1,2,4, 6,A,or C. e=Converter Model:C,or D. f=Lining: (any alphanumeric digit). g=Electrode: 1,3,4,5,6,7,G,M,R,or U. h=Construction of Electrodes: 1. DQD 507 Rev.2009-09-01 I csA INTERNATIONAL E[[ E Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2300463 Date Issued: 2010/05/14 i=Housing/Flange material: 1,3,4,A,C,D,K,M,or N. j =Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. I k=Cable:2 (Type 6P),or any other alphanumeric digit(Enclosure types other than 6P). 1=Cable Length:(any alphanumeric digit). m=Calibration:(any alphanumeric digit). n=G-P Ring/Material: (any alphanumeric digit). E } o=Special: 0. p=Module/labeled: 1 3 3 Notes: I 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DI7V2,IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. f • OPTIFLUX 5000-DIV2 series Primary Head.Model VN184abcdefghijkhnn. Operating ambient-50°C to 40°C;Temperature Code T6.Enclosure type as specified in the detail below. Where: a=Nominal Diameter: 1,2, 3, 5,6, 8,B, C, E, or F. b=Nominal Pressure:3,4,5,A, or B. E c=Approval: C. d=Cable Connection: 1,2,4,6,A,or C. I €[[F E DQD 507 Rev.2009-09-01 E f't CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2300463 Date Issued: 2010/05/14 0 e=Converter Model: C,or D. f=Mounting Material: (any alphanumeric digit). g=G-Ring Material/Gasket Material: (any alphanumeric digit). h=Electrode:0. i=Protection Class/dimension: 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. j =Cable:2(Type 6P),or any other alphanumeric digit(Enclosure types other than 6P). k=Cable Length:(any alphanumeric digit). 1=Calibration:(any alphanumeric digit). in=Special: 0. n=Module/labeled: 1 Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. • OPTIFLUX 5000-DIV2 VN244abcdefghijklmnop Primary Head.(Flange Version)Operating ambient-50°C to 40°C;Temperature Code T6.Enclosure type as specified in the detail below. Where: a=Nominal diameter:2,4, 6,7,A,B. b=Nominal pressure:3, 5 or A. c=Approval: C. E DQD 507 Rev.2009-09-01 CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 i Project: 2300463 Date Issued: 2010/05/14 d=Cable connection: 1,2,4, 6,A or C. F e=Converter model: C or D. f =Lining:not safety relevant. g=Electrode: 0. h=Construction of electrodes: 1. i =Housing/flange material: 0 j =Protection class/dimension:0 or 2. F k=Cable:2(Type 6P);Other—Not Safety Relevant. F 1 =Cable length:not safety relevant. € m=Calibration:not safety relevant. j n=G-P-Ring/Material:not safety relevant. ° o=Special:0. p=Module/labeled: 0 or 1. Notes: 1) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2,IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. 2) I.S.Electrodes when used with IFC 300 F-DIV2,IFC 300 F(/i)-DIV2, or IFC 090-F DIV2 signal converters. • OPTIFLUX 6000-DIV2 series Primary Head.Model VN224abcdefghijklmn. Operating ambient-50°C to 40°C;Temperature Code T6.Enclosure type as specified in the detail below. Where: t a—Nominal Diameter: 1,2,3,5,or 6. I DQD 507 Rev.2009-09-01 [Ff n CSA INTERNATIONAL e F F Certificate: 1665151 (LR 105802) Master Contract: 162767 f Project: 2300463 Date Issued: 2010/05/14 E b=Connection: 5,6,A,B,H,K,L,M,N,P, S,T,or U. i c=Approval: C. j d=Cable Connection: 1,2,4,6,A,or C. E e=Converter Model:C,or D. F f=Mounting Material:(any alphanumeric digit). g=G-Ring Material/Gasket Material: (any alphanumeric digit). h=Electrodes: 1,3,4,5,6,7,or A. [ f i=Protection Class/dimension: f f 0 indicates painted aluminum enclosure,rated Type 4X and Type 6. 2 indicates stainless steel enclosure,rated Type 6P. j =Cable:2(Type 6P),or any other alphanumeric digit(Enclosure types other than 6P). k=Cable Length:(any alphanumeric digit). 1=Calibration:(any alphanumeric digit). m=Special: 0. n=Module/labeled: 1 i E Notes: 3) OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. 4) I.S.Electrodes when used with IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 signal converters. • Primary Head Model IFS 4000 F-DIV2 series,magnetic flow meter sensor,rated 40 Vdc, 125mA. Install per Dwgs 8.30702.63 and 8.30702.64.Temperature Code T6,Ta=-50°C to 40°C. Notes: DQD 507 Rev.2009-09-01 E ee � CSA INTERNATIONAL ----------------------------- Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2300463 Date Issued: 2010/05/14 F 1) Primary Head,Model IFS 4000 F-DIV2 must only be used with Certified remote signal converter models IFC 300 F-DIV2,IFC 300 F(/i)- DIV2 or IFC 090-F DIV2. 2) I.S.Electrodes when used with remote signal converters,models IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 3) Internal order code known as type V303. E i • Primary Head Model IFS 5000 F-DIV2 series,magnetic flow meter sensor,rated 40 Vdc, 125mA.Install per Dwgs 8.30702.63 and 8.30702.64.Temperature Code T6,Ta=-50°C to 40°C. Notes: 1) Primary Head Model IFS 5000 F-DIV2 must only be used with Certified remote signal converter,models IFC 300 F-DIV2,IFC 300 F(/i)-DIV2 or IFC 090. i 2) I.S.Electrodes when used with remote signal converters,models IFC 300 F-DIV2,IFC 300 F(/i)-DIV2,or IFC 090-F DIV2 3) Internal order code known as type V304. r • IFC300 series Signal Converter.Model a VN304bcdefghijkhnno.Rated 100-230Vac,22VA,50-60 Hz and/or 12-24Vdc/24V ac/dc, 12W.Operating ambient-50°C to 40°C;Temperature Code T6.Enclosure type 4X,Type i 6. E E Where: E a=Input/Output: F(/i)-DIV2 indicates associated nomncendive field wiring and I.S. entity parameters,per control drawing 8.30702.65. F-DIV2 indicates normally nonarcing field wiring for use with Class I Div 2 wiring methods, E b=Type: 4,or H. c=Power Supply: 1,4, or A. 3 I I DQD 507 Rev.2009-09-01 CSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2300463 Date Issued: 2010/05/14 f d=Approval: C. e=Cable Connection:4,or 6. f=Instruction/Programming Language:(any alphanumeric digit). g=Custody Transfer:0. i h=Process Diagnostics:(any alphanumeric digit). i=Converter Housing: 1 indicates painted aluminum enclosure,rated Type 4X and Type 6. 1 2 indicates stainless steel enclosure,rated Type 4X and Type 6. j =Labeled: 1. k=Communications Slot I01 Selection: 1,2, 3,4,6,7, 8,B,C,D,E,F,G, or H. 1=First IO Module(IO2/A): 0, 1,2,8,A,B,C,E,F,G,H,or K. m=Second IO Module(IO2/13): 0, 8,A,B,C,E,F,G,H,or K. n=Reference Method: 0,or 1 o=Tagplate: (any alphanumeric digit). I 3 Notes: 1) OPTIFLUX IFC300 F signal converter electronics must be installed in explosionproof M14300C housing, and used with OPTIFLUX,IFS 4000E-DIV2 or IFS 5000E-DIV2 Primary Head. t t 2) Install per manufacturers drawings 8.30702.63 or 8.30702.64. i • OPTIFLUX a300 C-DIV2 Flowmeter.Rated 100-230Vac,22VA,50-60 Hz and/or 12-24Vdc/24V ac/dc, 12W. Operating ambient-50°C to 40°C;Temperature Code T6.Enclosure type 4X,Type 6. Where: a=Type: 1, 2,4, 5,or 6. f DQD 507 Rev.2009-09-01 GSA INTERNATIONAL Certificate: 1665151 (LR 105802) Master Contract: 162767 Project: 2300463 Date Issued: 2010/05/14 Consists of the OPTIFLUX a000-DIV2 series Primary Head(Where: a=Type: 1,2,4, 5, or 6),and the IFC300 F-DIV2 VN304bcdefghijklmno Signal Converter. • OPTIFLUX a300 C/i-DIV2 Flowmeter.Rated 100-230Vac,22VA,50-60 Hz and/or 12-24Vdc/24V ac/dc, 12W. Operating ambient-50°C to 40°C;Temperature Code T6.Enclosure type 4X,Type 6. I Where: F F a=Type: 1,2,4, 5, or 6. I E E Consists of the OPTIFLUX a000-DIV2 series Primary Head(Where:a=Type: 1,2,4,5,or 6),and the IFC300 F(/i)-DIV2 VN304bcdefghijklmno Signal Converter. i Note: 1) Nonincendive Field Wiring and Intrinsically Safe Entity Parameters when installed per manufacturers Control Drawings and drawing 8.30702.65. APPLICABLE REQUIREMENTS CAN/CSA Standard C22.2 No.0-M91 (Reaffirmed 2001)-General Requirements-Canadian Electrical Code,Part II CAN/CSA Standard C22.2 No.94-M94(Reaffirmed 2001)-Special Purpose Enclosures CSA Standard C22.2 No. 142-M1987(Reaffirmed 2000)-Process Control Equipment CSA Standard C22.2 No.25-1966(Reaffirmed 2000)-Enclosures for Use in Class II Groups E,F,and G Hazardous Locations CSA Standard C22.2 No.30-M1986(Reaffirmed 2003)-Explosion-Proof Enclosures for Use in Class I Hazardous Locations CAN/CSA Standard C22.2 No. 157-92(Including update No.2,June,2003)-Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations. I DQD 507 Rev.2009-09-01 CSA INTERNATIONAL [F Certificate: 1665151 (LR 105802) Master Contract: 162767 F Project: 2300463 Date Issued: 2010/05/14 CSA Standard C22.2 No.213-M1987(Reaffirmed 2008)-Non-incendive Electrical Equipment for Use in Class I,Division E 2 Hazardous Locations F E E F F E F I S f I F f DQD 507 Rev.2009-09-01 GSA INTERNATIONAL Supplement to Certificate of Compliance f Certificate: 1665151 Master Contract: 162767 The products listed,including the latest revision described below,are eligible to be marked in accordance with the referenced Certificate. Product Certification History Project Date Description 2300463 2010/05/14 Update to include OPTIFLUX 5000 Flange Version and minor report corrections with FM Revision Reports. 2230760 2009/12/11 Update to cover alternative primary heads IFS 4000/5000-F-DIV2. 2144298 2009/04/15 Update report 1665151 to reflect construction modifications and detail model codes. 1995761 2008/03/17 Update report to cover revised labels,Model number claification and addition of MODBUS IO for OPTIFLUX a300(Krohn ref S12 and S13). 1945264 2007/09/03 Update to report to cover minor modifications and alternate use of ET 2607 STK1 wire 1903147 2007/04/23 Update to report to include enclosure type 6P and IP68 1859129 2006/12/25 Update Report to add Virtual Reference Option(Krohne reference S8). 1836882 2006/11/09 Update Report to Add New Marking label(Krohen Reference S7.5) 1826377 2006/08/23 Update Report to Include Label to Show MWP for OPTIFLUX4000 1817210 2006/07/20 Update Report to Include MWP of 2220 psi for OPTIFLUX 4000 sizes 1"to 12" 1702107 2005/09/06 Update to report to cover use of alternate primary heads model OPTIFLUX 1000 and 1300 1665151 2005/05/13 Certification of Flowmeter System I F p€ p5E P S f i [ I