HomeMy WebLinkAboutAP_OPTIFLUX 1000-OPTIFLUX 2000-OPTIFLUX 4000-OPTIFLUX 5000-OPTIFLUX 6000-IFC 300_F_en_FM_090903__ CIM pprouals FM Approvals H 51 Boston Providence Turnpike P.O. Box 9102 Norwood,MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT This certificate is issued for the following equipment: OPTIFLUX 1000-DIV2 VN174abcdefghijk/mn. Primary Head. NI / I /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ II, III /2 / FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a= Nominal Diameter: 5, 6, 8, B, C, E, F or H. b = Nominal Pressure: A or B. c=Approval: 5 d = Systems Design: 1, 2, 3, 4, 6, A or C. e = Converter Model: C or D. f= Mounting Material: Not Safety Relevant g = Grounding ring material: Not Safety Relevant h = Electrodes: 0. i = Protection Class: 0 or 2. j = Cable: 2 (Type 6P); Other—Not Safety Relevant k= Cable Length: Not Safety Relevant I = Calibration: Not Safety Relevant m = Construction requirements: Not Safety Relevant n = QA/QC requirements: Not Safety Relevant Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(h)-DIV2 or IFC 090-F DIV2 signal converters. 2. I.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(h)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P& 1P68 rating only applies when configured with Stainless Steel Connection Box. 3022275 Page 1 of 9 CfM 00rouals OPTIFLUX 2000-DIV2 VN144abcdefghijklmnop Primary Head. NI / I /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ II, III /2 / FG /T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: 4, 5, 6, 7, 8, A, B, C or D b= Nominal pressure: 3, 4, 5, A or B c=Approval: 5 d = Cable connection: 1, 2, 4, 6, A or C e = Converter model: C or D f= Lining: not safety relevant g = Electrode: 1, 3 or 6 h = Construction of electrodes: 1 i = Housing/flange material: 1, 3 or 4 j = Protection class/dimension: 0 or 2 k= Cable: 2 (Type 6P); Other-Not Safety Relevant I = Cable length: not safety relevant m = Calibration: not safety relevant n = G-P-Ring/Material: not safety relevant o= Special: 0 p= Module/labeled: 1 Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(li)-DIV2 or IFC 090-F DIV2 signal converters. 2. /.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(l)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P&IP68 rating only applies when configured with Stainless Steel Connection Box. OPTIFLUX 2000-DIV2 VN154abcdefghijklmnop Primary Head. NI / I /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ II, III /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a= Nominal diameter: E, F, G, H, K, L, M or N b= Nominal pressure: 2, 3, 4, 5, A or B c=Approval: 5 d = Cable connection: 1, 2, 4, 6, A or C e= Converter model: C or D f= Lining: not safety relevant g = Electrode: 1, 3 or 6 h = Construction of electrodes: 1 i = Housing /flange material: 1, 3 or 4 j = Protection class\dimension: 0 or 2 k= Cable: 2 (Type 6P); Other-Not Safety Relevant I = Cable length: not safety relevant m = Calibration: not safety relevant n = G-P-Ring /Material: not safety relevant o = Special: 0 p = Module/labeled: 1 Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 2. 1.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(li)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P&IP68 rating only applies when configured with Stainless Steel Connection Box. 3022275 Page 2 of 9 C[M pprouals OPTIFLUX 2000-DIV2 VN164abcdefghijklmnop Primary Head. NI I I /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ II, III /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a= Nominal diameter: up to a maximum of 120" at 276 psi b = Nominal pressure: 1, 2 or A c=Approval: 5 d = Cable connection: 1, 2, 4, 6, A or C e= Converter model: C or D f= Lining: not safety relevant g = Electrode: 1, 3 or 6 h = Construction of electrodes: 1 i = Housing/flange material: 1, 3 or 4 j = Protection class/dimension: 0 or 2 k= Cable: 2 (Type 613); Other-Not Safety Relevant I = Cable length: not safety relevant m = Calibration: not safety relevant n = G-P-Ring /Material: not safety relevant o = Special: 0 p = Module/labeled: 1 Special conditions of use.- 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(fl)-DIV2 or IFC 090-F DIV2 signal converters. 2. /.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P&IP68 rating only applies when configured with Stainless Steel Connection Box. OPTIFLUX 4000-DIV2 VN024abcdefghijklmnop Primary Head. NI / I /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/II, III /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: 1, 2, 3, 5, 6 or 7 b = Nominal pressure: A or B c=Approval: 5 d = Cable connection: 1, 2, 4 or A e= Converter model: C or D f= Lining: not safety relevant g = Electrode: 1, 2, 3, 4, 5, 6, 7, G or U h = Construction of electrodes: 1 i= Housing /flange material: 1, 3, 4, E, G, K, M or N j = Protection class/dimension: 0 or 2 k = Cable: 2 (Type 6P); Other-Not Safety Relevant I = Cable length: not safety relevant m = Calibration: not safety relevant n = G-P-Ring/Material: not safety relevant o= Special: 0 p= Module I labeled: 1 Special conditions of use.- 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 2. /.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P& IP68 rating only applies when configured with Stainless Steel Connection Box. 3022275 Page 3 of 9 IM Approvals OPTIFLUX 4000-DIV2 VN034abcdefghijklmnop Primary Head. NI / I /2 /ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ Il, III /2 /FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: 1, 2, 3, 4, 5, 6, 7, 8, A, B, C or D b= Nominal pressure: 3, 4, 5, A, B, D or E c= Approval: 5 d = Cable connection: 1, 2, 4, 6, A or C e= Converter model: C or D f= Lining: not safety relevant g = Electrode: 1, 2, 3, 4, 5, 6, 7, G or U h = Construction of electrodes: 1 i = Housing/flange material: 1, 2, 3, 4, A, B, C, D, K, L, M or N j = Protection class/dimension: 0 or 2 k= Cable: 2 (Type 6P);Other-Not Safety Relevant I = Cable length: not safety relevant m = Calibration: not safety relevant n = G-P-Ring/Material: not safety relevant o= Special: 0 p= Module/labeled: 1 Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(h)-DIV2 or IFC 090-F DIV2 signal converters. 2. I.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(l)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P&IP68 rating only applies when configured with Stainless Steel Connection Box. OPTIFLUX 4000-DIV2 VN044abcdefghijklmnop Primary Head. NI/I/2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/II, III /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: E, F, G, H, K, L, M or N b = Nominal pressure: 2, 3, 4, 5, A or B c=Approval: 5 d = Cable connection: 1, 2, 4, 6, A or C e = Converter model: C or D f= Lining: not safety relevant g = Electrode: 1, 3, 4, 5, 6, 7, G, M, R or U h = Construction of electrodes: 1 i = Housing/flange material: 1, 3, 4, A, C, D, K, M or N j = Protection class/dimension: 0 or 2 k= Cable: 2 (Type 6P); Other-Not Safety Relevant I = Cable length: not safety relevant m = Calibration: not safety relevant n = G-P-Ring/Material: not safety relevant o= Special: 0 p = Module/ labeled: 1 Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(li)-DIV2 or IFC 090-F DIV2 signal converters. 2. 1.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(li)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P& IP68 rating only applies when configured with Stainless Steel Connection Box. 3022275 Page 4 of 9 f M Aporovals W, q OPTIFLUX 4000-DIV2 VN054abcdefghijklmnop Primary Head. NI / I /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ II, III /2 / FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: up to a maximum of 120" at 276 psi b = Nominal pressure: 1, 2 or A c=Approval: 5 d = Cable connection: 1, 2, 4, 6, A or C e= Converter model: C or D f= Lining: not safety relevant g = Electrode: 1, 3, 4, 5, 6, 7, G, M, R or U h = Construction of electrodes: 1 i = Housing/flange material: 1, 3, 4, A, C, D, K, M or N j = Protection class/dimension: 0 or 2 k= Cable: 2 (Type 6P); Other-Not Safety Relevant I = Cable length: not safety relevant m = Calibration: not safety relevant n = G-P-Ring/mat: not safety relevant o = Special: 0 p= Module/labeled: 1 Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(fl)-DIV2 or IFC 090-F DIV2 signal converters. 2. I.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(11)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P& IP68 rating only applies when configured with Stainless Steel Connection Box. OPTIFLUX 5000-DIV2 VN984abcdefghijklmn Primary Head. NI /I /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ll, III /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: 1, 2, 3, 5, 6, 8, B, C, E or F b= Nominal pressure: 3, 4, 5, A or B c=Approval: 5 d = Cable connection: 1, 2, 4, 6, A or C e= Converter model: C or D f= Mounting material: not safety relevant g = G-Ring mat./gasket mat: not safety relevant h = Electrode: 0 i = Protection class/dimension: 0 or 2 j = Cable: 2 (Type 6P); Other-Not Safety Relevant k= Cable length: not safety relevant I = Calibration: not safety relevant m = Special: 0 n = Module/labeled: 1 Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(h)-DIV2 or IFC 090-F DIV2 signal converters. 2. I.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P&IP68 rating only applies when configured with Stainless Steel Connection Box. 3022275 Page 5 of 9 CIM001ouals OPTIFLUX 5000-DIV2 VN244abcdefghijklmnop Primary Head. (Flange Version) NI / I /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ 11,111 /2 / FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: 2, 4, 6, 7, A, B. b = Nominal pressure: 3, 5 or A. c=Approval: 5. d = Cable connection: 1, 2, 4, 6, A or C. e = Converter model: C or D. f = Lining: not safety relevant. g = Electrode: 0. h = Construction of electrodes: 1. i = Housing/flange material: 0 j = Protection class/dimension: 0 or 2. k= Cable: 2 (Type 6P); Other- Not Safety Relevant. I = Cable length: not safety relevant. m = Calibration: not safety relevant. n = G-P-Ring/Material: not safety relevant. o= Special: 0. p= Module/labeled: 0 or 1. Special Conditions of Use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(ft)-DIV2 or IFC 090-F DIV2 signal converters. 2. I.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(h)-DIV2 or IFC 090-F DIV2 signal converters 3. *Enclosure Type 6P&IP68 rating only applies when configured with Stainless Steel Connection Box. OPTIFLUX 6000-DIV2 VN224abcdefghijk/mn Primary Head. NI / I /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/II, III /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a= Nominal diameter: 1, 2, 3, 5, 6 b = Connection: 5, 6, A, B, H, K, L, M, N, P, S, T or U c=Approval: 5 d = Cable connection: 1, 2,4, 6, A or C e = Converter model: C or D f= Mounting material: not safety relevant g = G-Ring mat./gasket mat: not safety relevant h = Electrodes: 1, 3, 4, 5, 6, 7 or A i = Protection class/dimension: 0 or 2 j = Cable: 2 (Type 6P);Other-Not Safety Relevant k= Cable length: not safety relevant I = Calibration: not safety relevant m = Special: 0 n = Module/labeled: 1 Special conditions of use.- 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 2. 1.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(Il)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P&IP68 rating only applies when configured with Stainless Steel Connection Box. IFC300 a VN304bcdefghijklmno Signal Converter. XP-ANI / I /2/ABCD/T6 Ta = 65°C-8.30702.61 or 8.30702.62; NIFW*; Type 4X, Type 6 DIP-ANI / 11, III /2 / EFG/Ta = 65°C-8.30702.61 or 8.30702.62; NIFW*;Type 4X, Type 6; AIS/ I / 1 /ABCDEFG- 8.30702.61 or 8.30702.62; Entity; Type 4X, Type 6, 3022275 Paoe 6 of 9 Curouals For Entity Parameters and Nonincendive Field Wiring Parameters reference control drawings and,drawing 8.30702.65 " The signal converter is configured with Entity Parameters and Nonincendive Field Wiring Parameters only when option a = F (/i)-DIV2. a = Input/Outputs: F (/i)-DIV2 or F-DIV2 b = Type: 4 or H c = Power Supply: 1, 4 or A d =Approval 5. e= Cable connection: 4, or 6 f= instruction/ Program Language: not safety relevant g = Custody Transfer: 0 h = Process diagnostics: not safety relevant i = Converter housing: 1 or 2 j = Labeled: 1 k= Communication Slot 101 Selection: 1, 2, 3, 4, 6, 7, 8, B, C, D, E, F, G or H. 1 = 1 st 10 Module (102/A): 0, 1, 2, 8, A, B, C,E, F, G, H, or K. m =2nd 10 Module (102 /B): 0, 8, A, B, C, E, F, G, H, or K n = Reference method: 0 or 1. o=Tagplate: Not safety relevant Special Conditions for Use: 1) OPTIFLUX IFC 300 F signal converter electronics must be installed in explosionproof MH300C housing and used with OPTIFLUX Primary Head. 3022275 Page 7 of 9 CIM 00ravals OPTIFLUX a300 C—DIV2.Flowmeter. XP/ I /2/ABCD/T6 Ta =65°C; Type 4X, Type 6 DIP / II, III /2/FG/Ta = 65°C; Type 4X, Type 6 a = Type 1, 2, 4, 5, or 6 The OPTIFLUX a300 series flowmeter is the integration of the OPTIFLUX a000—DIV2 Primary Head and the model IFC300 F-DIV2 VN304bcdefghijklmno Signal Converter. OPTIFLUX a300 C/I—DIV2.Flowmeter. XP-ANI / 1 /2/ABCD/T6 Ta= 65°C—8.30702.61 or 8.30702.62; NIFW; Type 4X, Type 6 DIP-AN[ /II, 111 /2/ FG/Ta = 65°C—8.30702.61 or 8.30702,62; NIFW; Type 4X, Type 6 For Entity Parameters and Nonincendive Field Wiring Parameters reference control drawings and drawing 8.30702.65 a =Type 1, 2, 4, 5, or 6 The OPTIFLUX a300 series flowmeter is the integration of the OPTIFLUX a000—DIV2 Primary Head and the model IFC 300 F(/i)-DIV2 VN304bcdefghijklmno Signal Converter. Equipment Ratings: Explosionproof for use in Class I, Division 2, Groups A, B, C and D; Dust-I g n ition proof for use in Class 11, III, Division 2, Groups F and G indoor/outdoor hazardous (classified) locations, utilizing Type 4X, 6, or 6P enclosure with intrinsically safe connections to Class 1, 11, 111, Division 1, Group A, B, C, D, E, F and G hazardous (classified) locations. Temperature Class T6 Ta =65°C Explosionproof for use in Class I, Division 2, Groups A, B, C and D; Dust-Ignitionproof for use in Class II, 111, Division 2, Groups F and G indoor/outdoor hazardous(classified) locations, utilizing Type 4X, 6, or 6P enclosure with nonincendive field wiring connections to Class I, 11, III, Division 2, Group A, B, C, D, F and G hazardous (classified) locations. The examination was based on the installation of the apparatus being installed in accordance with control drawings 8,30702.61 or 8,30702.62. Temperature Class T6 Ta =65°C FM Approved for: KROHNE Altometer Kerkeplaat 12, 3313 LC Dordrecht, the Netherlands 3022275 Page 8 of 9 <:::fM Amouals 11'"'/",.d rho/11 tN "!i G... This certifies that the equipment described has been found to comply with the following Approval Standards and other documents: Class 3600 1998 Class 3610 1999 Class 3611 2004 Class 3615 1989 Class 3810 1989 Original Project ID: 3022275 Approval Granted: January 3, 2005 Subsequent Revision Reports / Date Approval Amended Report Number Date Report Number Date 050228 March 11, 2005 050323 March 28, 2005 050715 July 21, 2005 060724 August 25, 2006 060914 November 2, 2006 3026758 February 2, 2007 070209 April 11, 2007 071001 November 13, 2007 080314 March 24, 2008 080808 October 9, 2008 081028 November 20, 2008 090622 August 11, 2009 090824 � e FM Approvals LLC J.I . Marquedant I Date roup Manager, Electrical 3022275 Page 9 of 9