HomeMy WebLinkAboutAP_OPTIFLUX 2000-OPTIFLUX 4000-IFC 100_C_en_IECEx_100118__ IECEx Certificate
wi of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit wvm.iecex.com
Certificate No.: IECEx KEM 09.0073X issue No.:O
Certificate history:
Status: Current
Date of Issue: 2010-01-18 Page 1 of 3
Applicant: Krohne Altometer
Kerkeplaat 12
3313 LC Dordrecht
The Netherlands
Electrical Apparatus: Compact Electromagnetic Flowmeter types OPTIFLUX 2100 C and OPTIFLUX 4100 C
Optional accessory:
Type of Protection: d,e, mb,ia,tD
Marking: Ex a is mb IIC T4
Ex deiambllCT4
Ex tD A21 IP64 T120°C
Approved for issue on behalf of the IECEx T. Pijpker
Certification Body:
Position: Ce 'fication Ma Ser
Signature:
(for printed version)
Date: 'LO l fl _ L
1.This certificate and schedule may only be reproduced in full.
2.This certificate is not transferable and remains the property of the issuing body.
3.The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
Certificate issued by:
KEMA Quality B.V.
Utrechtseweg 310
6812 AR Arnhem
The Netherlands CEM
a IECEx Certificate
of Conformity
Certificate No.: IECEx KEM 09.0073X
Date of Issue: 2010-01-18 Issue No.: 0
Page 2 of 3
Manufacturer: Krohne Altometer
Kerkeplaat 12
3313 LC Dordrecht
The Netherlands
Manufacturing location(s):
This certificate is issued as verification that a sample(s), representative of production,was assessed and tested and
found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products
covered by this certificate,was assessed and found to comply with the IECEx Quality system requirements.This
certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents
as amended.
STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified
documents,was found to comply with the following standards:
IEC 60079-0: 2004 Electrical apparatus for explosive gas atmospheres-Part 0: General requirements
Edition:4.0
IEC 60079-1 : 2007-04 Explosive atmospheres-Part 1: Equipment protection by flameproof enclosures"d"
Edition:6
IEC 60079-11 : 2006 Explosive atmospheres-Part 11: Equipment protection by intrinsic safety"i"
Edition:5
IEC 60079-18: 2004 Electrical apparatus for explosive gas atmospheres-Part 18:Construction,test and
Edition:2.0 marking of type of protection encapsulation'm'electrical apparatus
IEC 60079-7 : 2006-07 Explosive atmospheres-Part 7: Equipment protection by increased safety"e"
Edition:4
IEC 61241-0 : 2004 Electrical apparatus for use in the presence of combustible dust-Part 0: General
Edition: 1 requirements
IEC 61241-1 : 2004 Electrical apparatus for use in the presence of combustible dust-Part 1: Protection by
Edition: 1 enclosures"tD"
This Certificate does not indicate compliance with electrical safety and performance requirements other than those
expressly included in the Standards listed above.
TEST&ASSESSMENT REPORTS:
A sample(s)of the equipment listed has successfully met the examination and test requirements as recorded in
Test Report:
NUKEM/ExTR09.0069/00
Quality Assessment Report:
NUKEM/QAR09.0012/00
IECEx Certificate
of Conformity
Certificate No.: IECEx KEM 09.0073X
Date of Issue: 2010-01-18 Issue No.: 0
Page 3 of 3
Schedule
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
The Compact Electromagnetic Flowmeter,types OPTIFLUX 2100 C and 4100 C is used for measuring,counting and
displaying the linear flow of an electrically conductive liquid.
The flowmeter consists of an aluminium signal converter housing containing the electronics and a steel primary head.
See Attachment for more details and electrical data.
CONDITIONS OF CERTIFICATION:YES as shown below:
The property class of the special fasteners of the Ex d primary heads shall beat least A*-70.
- For details of the flameproof joint between the Ex d primary head and the cable feedthrough the manufacturer shall be
contacted.
Annexe: ExTR09.0069 Attachment 1 to IECEx.doc
OEM
Attachment 1 to IECEx KEM 09.0073X
Description
The Compact Electromagnetic Flowmeter, types OPTI FLUX 2100 C and 4100 C is used for measuring,
counting and displaying the linear flow of an electrically conductive liquid.
The flowmeter consists of an aluminium signal converter housing containing the electronics and a steel
primary head.
The signal converter housing with electronics is in type of protection increased safety"e", encapsulation
"mb" and intrinsic safety"i".
The type of protection for the various sizes of the integral primary heads is as follows:
DN10- DN20: encapsulation "mb" (field coils) and increased safety"e" (field coil wiring) or
DN25- DN150: flameproof enclosures"d" (field coils and field coil wiring) or
DN200 - DN3000: increased safety"e" (field coils and field coil wiring).
The electrodes are in type of protection intrinsic safety"i".
Ambient temperature range: -20 °C to+40 °C
Process temperature range: -20 °C to+120 °C
The degree of protection of the apparatus enclosure is at least IP64 according to IEC 60529.
Electrical data
Power supply ...................................... Un = 100-230 Vac, +10 % /-15 %, 8 VA resp.
(terminals L, N or L+, L-) Un = 24 Vdc, +30 %/-25 %, 4 W
U„ = 24 Vac, +10 %/-15 %, 8 VA
Um = 253 V
Current output ..................................... Un <_ 32 Vdc, passive or active, 4 -20 mA, HART
(terminals A+, A, A-) Um = 253 V
Status/ Pulse/ Frequency output ....... U„ <_ 32 Vdc, 1 <_50 mA
(terminals C+, C, D+, D, S) Um = 253 V
Display and electrode circuit ................. in type of protection intrinsic safety Ex is IIC
(internal circuit)
The intrinsically safe electrode circuit and the intrinsically safe display circuit are galvanically connected
with each other and with the non-intrinsically safe field coil circuit. These three circuits are infallibly
galvanically isolated from all other non-intrinsically safe circuits to a peak value of the nominal voltage
of 375 V.