Loading...
HomeMy WebLinkAboutAP_OPTIFLUX 2000__en_UBA PO liner_120120___ Hygiene-Institut des Ruhrgebiets L7 Institut fur Umwelthygiene and Toxikologie Direktor: Prof. Dr. rer. nat. L. Dunemann Mi HYGIENE-INSTITUT Postfach 10 12 55 45812 Gelsenkirchen I GERMANY Visitor-/Parcel Address: Rotthauser Str.21 KROHNE Altometer 45879 Gelsenkirchen Kerkeplaat 12 Telephone +49(0)209 9242-0 3313 LC DORDRECHT Extension +49(0)209 9242-210 THE NETHERLANDS Telefax +49(0)209 9242-212 E-Mail a.koch@hyg.de Internet www.hyg.de Reference-No.: K-212125.12-Kolst Contact person: Dr.Andreas Koch Redraft: K-197509-10-Ko Gelsenkirchen, 20.01.2012 TEST CERTIFICATE according to the UBA-Guideline for the hygienic assessment of"organic coatings in contact with drinking water" Product: PO liner for OPTIFLUX 2000 Electromagnetic Flowmeters family Test specimen: coated test plates(uncoloured,white) The test specimen meets the requirements according to the test report dated 20.01.2012 Ref.-No.: K-212125-12-Ko/st for the following application(s)and temperature(s), as far as technically suited. A p p l i c a t i o n s: cold water warm water hot water (23 C) (g0°C) (85-C) Pipes with DN<80 mm(domestic distribution) --- --- --- Pipes of diameter 80 mm<_DN <300 mm (supply pipes) --- --- --- Pipes of diameter DN>_300 mm (main pipes) --- --- --- Fittings for pipes with DN<80 mm passed --- --- Fittings for pipes with 80 mm s DN <300 mm passed --- --- Fittings for pipes with DN>_300 mm passed --- --- Sealings for pipes with DN<80 mm passed --- --- Sealings for pipes with 80 mm<_DN<300 mm passed --- --- Sealings for pipes with DN a 300 mm passed --- --- Tanks in the domestic installations including repair systems --- --- --- Tanks other than in domestic installations including repair systems passed --- --- Repair systems for tanks in domestic installations with 1/100 of the area of the tank passed --- --- Repair systems for tanks othe than in domestic installations with 1/100 of the area of the tank passed --- --- If pipes, sealings or fittings and ancillaries do not differ in their material composition and process of manufacture, testing of the smallest diameter of the product range is sufficient. This test certificate is valid beginning with the date of issue and is ending by 10.12.2015 as far as there are no changes in the formula.After this time it can be extended for further 5 years if demanded. The Director of the Hygiene-Institute �,�e\tkiygiar r, on behalf of s Dr. rer. n tuAd"reas Koch r Head oft a Dept.for water hygienic material testings The assessment was based on the assumption that the used starting substances and monomers used to ```%i, manufacture the product may completely known and no other substances are present in the product.The validity of this document expires in case of modifications in the composition of the product or the processing conditions. CC DAkkS The results and evaluations refer to the groups of test items.This document may not be published without our %i Akkredhti rungsstelle written permission only complete and unchanged or duplicated. D-PL-13042-02-00 .......................................................................................... ........... Trager des Instituts: Verein zur Bekampfung der Volkskrankheiten im Ruhrkohlengehiet e.V., Gelsenkirchen, Vereinsregister: VR 519 Amtsgericht Gelsenkirchen USt.-ID: DE125018356, Vorstand: Prof. Dr. Werner Schlake IVors.l, Prof. Or. Jurgen Kretschmann, Dr. Emanuel Griln, Volker Vohmann, Prof. Dr. Lothar Dunemann