HomeMy WebLinkAboutAP_OPTIFLUX 2300-OPTIFLUX 4300__en_NMi OIML_060317__ i
M Nederlands Meetinstituut
OIML Certificate NO R49-1/2003-NL1-06.01
OIML Member state Project number 409580
The Netherlands Page 1 of 4
OIML CERTIFICATE OF CONFORMITY
Issuing authority
Name: NMi Certin B.V.
Address: Hugo de Grootplein 1,
3314 EG Dordrecht
The Netherlands
Person responsible: Ing. C. Oosterman
Applicant
Name: Krohne Altometer
Address: Kerkeplaat 12
3313 LC Dordrecht
The Netherlands
Manufacturer of the certified type
Name: Krohne Altometer
Address: Kerkeplaat 12
3313 LC Dordrecht
The Netherlands
Identification of certified type
Type : OPTIFLUX x3000'I; OPTIFLUX x000F1'I + IFC300
Water meter intended for the metering of cold potable water, model "OPTIFLUX x3000'I;
OPTIFLUX x000F1'l + IFC300", class 1 and 2.
Further characteristics: see page 3.
I'I With x being 2 or 4.
NMi Certin B.V. Parties concerned can lodge objection against This document is issued under the provision that
Hugo de Grootplein 1,3314 EG Dordrecht this decision,within six weeks after the date no responsibility is accepted and that the
P.O.Box 394,3300 AJ Dordrecht,NL of submission,to the general manager of NMi applicant gives warranty for each responsibility
B.V.(see"Regulation objection and appeal against third parties.
phone+31 78 6332332 against decisions of NMi B.V.")
fax+31 78 6332309 The notification of NMi Certin as Issuing
certin@nmi.nl NMi Certin B.V.,chamber o.c.nr.27.233.418 Authority can be verified at www.oimi.org.
www.nmi.nl
E
0
i
M � 'Nederlands Meetinstituut
OIML Certificate NO R49-1/2003-NL1-06.01
Project number 409580
Page 2 of 4
This Certificate attests the conformity of the above identified type (represented by the sample or
samples identified in the associated Test Report) with the requirements of the following
Recommendation of the International Organization of Legal Metrology (OIML):
R49-1/2003 (E): Metrological and technical requirements
R49-2/2004 (E): Test methods
R49-3/2004 (E): Test Report format
This Certificate relates only to the metrological and technical characteristics of the type of instrument
covered by the relevant OIML Recommendation identified above.
This Certificate does not bestow any form of legal international approval.
The conformity was established by the results of tests and examinations provided in the associated
Test Report:
No. R49-1/2003-NL1-06.01 that includes 41 pages
No. R49-1/2003-NL1-06.01- Annex A that includes 1 page
- No. R49-1/2003-NL1-06.01; Annex 1 that includes 21 pages
No. R49-1/2003-NL1-06.01; Annex 2 that includes 4 pages
No. R49-1/2003-NL1-06.01; Annex 3 that includes 11 pages
No. R49-1/2003-NL1-06.01; Annex 4 that includes 9 pages
No. R49-1/2003-NL1-06.01; Annex 5 that includes 7 pages
No. R49-1/2003-NL1-06.01; Annex 6 that includes 9 pages
No. R49-1/2003-NL1-06.01; Annex 7 that includes 8 pages
No. R49-1/2003-NL1-06.01; Annex 8 that includes 5 pages
No. R49-1/2003-NL1-06.01; Annex 9 that includes 2 pages
No. R49-1/2003-NL1-06.01; Annex 10 that includes 2 pages
No. R49-1/2003-NL1-06.01; Annex 11 that includes 8 pages
No. R49-1/2003-NL1-06.01; Annex 12 that includes 16 pages
No. R49-1/2003-NL1-06.01; Annex 13 that includes 4 pages
No. R49-1/2003-NL1-06.01; Annex 14 that includes 4 pages
No. R49-1/2003-NL1-06.01; Annex 15 that includes 6 pages
- No. R49-1/2003-NL1-06.01; Annex 16 that includes 9 pages
- No. R49-1/2003-NL1-06.01; Annex 17 that includes 26 pages
The Issuirfg Authority
Ing. C. Oosterman
Manager Product C ification
I/
D : Ma 17, 2006
Important note: Apart from the mention of the Certificate's reference number and the name of the
OIML Member State in which the Certificate is issued, partial quotation of the
Certificate and of the associated Test Report is not permitted, although either may
" be reproduced in full.
E
0
i
MNederlands Meetinstituut
OIML Certificate N° R49-1/2003-NL1-06.01
Project number 409580
Page 3 of 4
Identification of the certified pattern —continued from page 1
Water meter intended for metering cold potable water, based on a electromagnetic principle,
designed to measure reverse flow, with straight inlet and outlet length, with no flow conditioner and
equipped with an electronic calculating/indicating device.
Metrological characteristics:
Type: OPTIFLUX x300CI'l, complete water meter
OPTIFLUX x000FI'l + IFC300, combined water meter
Meter size DN25 DN50 DN80 DN100
Minimum flow rate Q1 (m3/h) 0,040 0,10 0,25 0,4
Transitional flow rate Q2 (m3/h) 0,064 0,16 0,40 0,6
Permanent flow rate Q3 (m3/h) 16 40 160 250
Overload flow rate Q4 (m3/h) 20 50 200 312,5
Nominal diameter(mm) 25 50 80 100
Accuracy Class 2 1
Maximum admissible pressure (bar) 16
Min/max admissible temperature (°C) 0,1 / 50
Indicating range (m3)(2][41 99.999 999.999
Verification scale interval (m3)I3j[41 0,0001 0,001
Orientation All positions
Environmental class C
Power supply
Type mains AC DC
Umax 230 V 24 V
Umin 100 V 12 V
Frequency 50—60 Hz -
With x being 2 or 4.
(21 The indicating range is programmable, stated here is the minimum indicating range.
(31 The verification scale interval is programmable, stated here is the maximum value.
[4) The display of the totalizator has 11 digits (including 1 digit for the decimal sign. The format of
the totalizator must be such that demands of the indicating range and the verification scale
interval are met.
E
s
i
M1 Nederlands Meetinstituut
OIML Certificate No R49-1/2003-NL1-06.01
Project number 409580
Page 4 of 4
Meter size DN150 DN250 DN500
Minimum flow rate Q1 (m3/h) 0,6 1,6 12,6
Transitional flow rate Q2 (m3/h) 1,0 2,6 20,2
Permanent flow rate Q3 (m3/h) 400 1600 6300
Overload flow rate Q4 (m3/h) 500 2000 7875
Nominal diameter (mm) 150 250 500
Accuracy Class 1
Maximum admissible pressure (bar) 16
Min/max admissible temperature (°C) 0,1 / 50
Indicating range (m3)['1[31 999.999 9.999.999 99.999.999
Verification scale interval (Ml)[2][31 0,001 0,01
Orientation All positions
Environmental class C
Power supply
Type mains AC DC
Umax 230 V 24 V
Umin 100 V 12 V
Frequency 50—60 Hz -
The indicating range is programmable, stated here is the minimum indicating range.
[21 The verification scale interval is programmable, stated here is the maximum value.
131 The display of the totalizator has 11 digits (including 1 digit for the decimal sign. The format of
the totalizator must be such that demands of the indicating range and the verification scale
interval are met.
E
s