HomeMy WebLinkAboutAP_OPTIFLUX__en_FM_120214__ CFM pprouaIr FM Approvals Member of the FM Global Group 1151 Boston Providence Turnpike P.O.Box 9102 Norwood,MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT This certificate is issued for the following equipment: OPTIFLUX 1000-DIV2 VN174abcdefghijklmn. Primary Head. NI / 1 /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ 11, III /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal Diameter: 5, 6, 8, B, C, E, F or H. b = Nominal Pressure: A or B. c =Approval: 5 d = Systems Design: 1, 2, 3, 4, 6, A or C. e = Converter Model: C or D. f= Mounting Material: Not Safety Relevant g = Grounding ring material: Not Safety Relevant h = Electrodes: 0 or B. i = Protection Class: 0 or 2. j = Cable: 2 (Type 6P); Other—Not Safety Relevant k = Cable Length: Not Safety Relevant I = Calibration: Not Safety Relevant m = Construction requirements: Not Safety Relevant n = QA/QC requirements: Not Safety Relevant Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 2. I.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P& IP68 rating only applies when configured with Stainless Steel Connection Box. 3022275 Page 1 of 9 CFM 010valso Af mh-nPh,F4f Ghd-,1 Group OPTIFLUX 2000-DIV2 VN144abcdefghijklmnop Primary Head. NI / 1 /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ 11, 111 /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: 4, 5, 6, 7, 8, A, B, C or D b = Nominal pressure: 3, 4, 5, A or B c=Approval: 5 d = Cable connection: 1, 2, 4, 6, A or C e = Converter model: C or D f= Lining: not safety relevant g = Electrode: 1, 3, 6 or B h = Construction of electrodes: 1 i = Housing/flange material: 1, 3, 4, A, C or D j = Protection class/dimension: 0 or 2 k = Cable: 2 (Type 6P); Other-Not Safety Relevant I = Cable length: not safety relevant m = Calibration: not safety relevant n = G-P-Ring/ Material: not safety relevant o = Special: 0 p = Module/labeled: 0 or 1 Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 2. 1.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P& IP68 rating only applies when configured with Stainless Steel Connection Box. OPTIFLUX 2000-DIV2 VN154abcdefghijklmnop Primary Head. NI / 1 /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ II, III /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: E, F, G, H, K, L, M or N b = Nominal pressure: 2, 3, 4, 5, A or B c=Approval: 5 d = Cable connection: 1, 2, 4, 6, A or C e = Converter model: C or D f= Lining: not safety relevant g = Electrode: 1, 3, 6 or B h = Construction of electrodes: 1 i = Housing/flange material: 1 or 3 j = Protection class\dimension: 0 or 2 k = Cable: 2 (Type 6P); Other-Not Safety Relevant I = Cable length: not safety relevant m = Calibration: not safety relevant n = G-P-Ring/ Material: not safety relevant o = Special: 0 p = Module/labeled: 0 or 1 Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 2. /.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P& IP68 rating only applies when configured with Stainless Steel Connection Box. 3022275 Page 2 of 9 CFM 010valso Af mh-nPh,F4f Ghd-,1 Group OPTIFLUX 2000-DIV2 VN164abcdefghijklmnop Primary Head. NI / 1 /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ 11, 111 /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: up to a maximum of 120" at 276 psi b = Nominal pressure: 1, 2, A or W c=Approval: 5 d = Cable connection: 1, 2, 4, 6, A or C e = Converter model: C or D f= Lining: not safety relevant g = Electrode: 1, 3, 6 or B h = Construction of electrodes: 1 i = Housing/flange material: 1 or 3 j = Protection class/dimension: 0 or 2 k = Cable: 2 (Type 6P); Other-Not Safety Relevant I = Cable length: not safety relevant m = Calibration: not safety relevant n = G-P-Ring/Material: not safety relevant o = Special: 0 p = Module/labeled: 0 or 1 Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(h)-DIV2 or IFC 090-F DIV2 signal converters. 2. 1.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(h)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P& IP68 rating only applies when configured with Stainless Steel Connection Box. OPTIFLUX 4000-DIV2 VN024abcdefghijklmnop Primary Head. NI / I /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ 11, 111 /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: 1, 2, 3, 5, or 6 b = Nominal pressure: A or B c=Approval: 5 d = Cable connection: 1, 2, 4 or A e = Converter model: C or D f= Lining: not safety relevant g = Electrode: 1, 3, 4, 5, 6, 7 or B h = Construction of electrodes: 1 i = Housing/flange material: E or F j = Protection class/dimension: 0 or 2 k = Cable: 2 (Type 6P); Other-Not Safety Relevant I = Cable length: not safety relevant m = Calibration: not safety relevant n = G-P-Ring/ Material: not safety relevant o = Special: 0 p = Module/labeled: 0 or 1 Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 2. 1.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P& IP68 rating only applies when configured with Stainless Steel Connection Box. 3022275 Page 3 of 9 CFM 010valso Af mh-nPh,F4f Ghd-,1 Group OPTIFLUX 4000-DIV2 VN034abcdefghijklmnop Primary Head. NI / 1 /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ 11, 111 /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: 1, 2, 3, 4, 5, 6, 7, 8, A, B, C or D b = Nominal pressure: 3, 4, 5, A, B, D or E c=Approval: 5 d = Cable connection: 1, 2, 4, 6, A or C e = Converter model: C or D f= Lining: not safety relevant g = Electrode: 1, 2, 3, 4, 5, 6, 7, B, G, N or U h = Construction of electrodes: 1 i = Housing/flange material: 1, 3, 4, A, C or D j = Protection class/dimension: 0 or 2 k = Cable: 2 (Type 6P); Other-Not Safety Relevant I = Cable length: not safety relevant m = Calibration: not safety relevant n = G-P-Ring/Material: not safety relevant o = Special: 0 p = Module/labeled: 0 or 1 Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 2. I.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P& IP68 rating only applies when configured with Stainless Steel Connection Box. OPTIFLUX 4000-DIV2 VN044abcdefghijklmnop Primary Head. NI / I /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ 11, 111 /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: E, F, G, H, K, L, M or N b = Nominal pressure: 2, 3, 4, 5, A or B c=Approval: 5 d = Cable connection: 1, 2, 4, 6, A or C e = Converter model: C or D f= Lining: not safety relevant g = Electrode: 1, 3, 4, 5, 6, 7, B, G, N or U h = Construction of electrodes: 1 i = Housing/flange material: 1 or 3 j = Protection class/dimension: 0 or 2 k = Cable: 2 (Type 6P); Other-Not Safety Relevant I = Cable length: not safety relevant m = Calibration: not safety relevant n = G-P-Ring/ Material: not safety relevant o = Special: 0 p = Module/labeled: 0 or 1 Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 2. I.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P& IP68 rating only applies when configured with Stainless Steel Connection Box. 3022275 Page 4 of 9 CFM 010valso Af mh-nPh,F4f Ghd-,1 Group OPTIFLUX 4000-DIV2 VN054abcdefghijklmnop Primary Head. NI / 1 /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ 11, 111 /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: up to a maximum of 120" at 276 psi b = Nominal pressure: 1, 2 or A c=Approval: 5 d = Cable connection: 1, 2, 4, 6, A or C e = Converter model: C or D f= Lining: not safety relevant g = Electrode: 1, 3, 4, 5, 6, 7, B, G, N or U h = Construction of electrodes: 1 i = Housing/flange material: 1 or 3 j = Protection class/dimension: 0 or 2 k = Cable: 2 (Type 6P); Other-Not Safety Relevant I = Cable length: not safety relevant m = Calibration: not safety relevant n = G-P-Ring/mat: not safety relevant o = Special: 0 p = Module/labeled: 0 or 1 Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 2. L S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P& IP68 rating only applies when configured with Stainless Steel Connection Box. OPTIFLUX 5000-DIV2 VN184abcdefghijklmn Primary Head. NI / 1 /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ II, III /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: 1, 2, 3, 5, 6, 8, B, C, E or F b = Nominal pressure: 3, 4, 5, A or B c=Approval: 5 d = Cable connection: 1, 2, 4, 6, A or C e = Converter model: C or D f= Mounting material: not safety relevant g = G-Ring mat./gasket mat: not safety relevant h = Electrode: 0 i = Protection class/dimension: 0 or 2 j = Cable: 2 (Type 6P); Other-Not Safety Relevant k = Cable length: not safety relevant I = Calibration: not safety relevant m = Special: 0 n = Module/labeled: 0 or 1 Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 2. I.S. Electrodes when used with IFC 300 F-DIV21 IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P& IP68 rating only applies when configured with Stainless Steel Connection Box. 3022275 Page 5 of 9 CFM 010valso Af mh-nPh,F4f Ghh,-,1 Group OPTIFLUX 5000-DIV2 VN244abcdefghijklmnop Primary Head. (Flange Version) NI / 1 /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ 11,111 /2/ FG /T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: 2, 4, 6, 7, A, B. b = Nominal pressure: 3, 5 A, or B c =Approval: 5. d = Cable connection: 1, 2, 4, 6, A or C. e = Converter model: C or D. f = Lining: not safety relevant. g = Electrode: 0. h = Construction of electrodes: 1. i = Housing/flange material: 0 j = Protection class/dimension: 0 or 2. k = Cable: 2 (Type 6P); Other- Not Safety Relevant. I = Cable length: not safety relevant. m = Calibration: not safety relevant. n = G-P-Ring/Material: not safety relevant. o = Special: 0. p = Module/labeled: 0 or 1. Special Conditions of Use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 2. /.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters 3. *Enclosure Type 6P&IP68 rating only applies when configured with Stainless Steel Connection Box. OPTIFLUX 6000-DIV2 VN224abcdefghijklmn Primary Head. NI / 1 /2/ABCD/T6; Type 4X, Type 6, *Type 6P; *IP68 S/ 11, III /2/ FG/T6; Type 4X, Type 6, *Type 6P; *IP68 a = Nominal diameter: 1, 2, 3, 5, 6 b = Connection: H, K, L, N, P, S, T or U c=Approval: 5 d = Cable connection: 1, 2, 4, 6, A or C e = Converter model: C or D f= Mounting material: not safety relevant g = G-Ring mat./gasket mat: not safety relevant h = Electrodes: 1, 3, 4, 5, 6, 7, A or B i = Protection class/dimension: 0 or 2 j = Cable: 2 (Type 6P); Other-Not Safety Relevant k = Cable length: not safety relevant I = Calibration: not safety relevant m = Special: 0 n = Module/labeled: 0 or 1 Special conditions of use: 1. OPTIFLUX Primary Head must be used with the IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 2. I.S. Electrodes when used with IFC 300 F-DIV2, IFC 300 F(/i)-DIV2 or IFC 090-F DIV2 signal converters. 3. *Enclosure Type 6P& IP68 rating only applies when configured with Stainless Steel Connection Box. 3022275 Page 6 of 9 CFM 010valso Af mh- .Ih,F4f Ghd-,1 Group IFC300 a VN304bcdefghijklmno Signal Converter. XP-ANI / I /2/ABCD/T6 Ta = 65°C-8.30702.61 or 8.30702.62; NIFW*; Type 4X, Type 6 DIP-ANI / 11, III /2/ EFG/Ta = 65°C-8.30702.61 or 8.30702.62; NIFW*;Type 4X, Type 6; AIS/ 1,11,111 / 1 /ABCDEFG-8.30702.61 or 8.30702.62; Entity; Type 4X, Type 6; For Entity Parameters and Nonincendive Field Wiring Parameters reference control drawings and drawing 8.30702.65 * The signal converter is configured with Entity Parameters and Nonincendive Field Wiring Parameters only when option a = F (/i)-DIV2. a = Input/Outputs: F (/i)-DIV2 or F-DIV2 b = Type: 4 or H c= Power Supply: 1, 4 or A d =Approval 5. e = Cable connection: 4, or 6 f= Instruction / Program Language: not safety relevant g = Custody Transfer: 0 h = Process diagnostics: not safety relevant i = Converter housing: 1 or 2 j = Labeled: 1 k = Communication Slot 101 Selection: 1, 2, 3, 4, 6, 7, 8, B, C, D, E, F, G or H. I = 1st 10 Module (102/A): 0, 1, 2, 8, A, B, C,E, F, G, H, or K. m =2nd 10 Module (102/B): 0, 8, A, B, C, E, F, G, H, or K n = Reference method: 0 or 1. o = Tagplate: Not safety relevant Special Conditions for Use: 1) OPTIFLUX IFC 300 F signal converter electronics must be installed in explosionproof MH300C housing and used with OPTIFLUX Primary Head. OPTIFLUX a300 C-DIV2.Flowmeter. XP/ 1 /2/ABCD/T6 Ta = 65°C; Type 4X, Type 6 DIP/ 11, 111 /2/ FG /Ta = 65°C; Type 4X, Type 6 a =Type 1, 2, 4, 5, or 6 The OPTIFLUX a300 series flowmeter is the integration of the OPTIFLUX a000-DIV2 Primary Head and the model IFC300 F-DIV2 VN304bcdefghijklmno Signal Converter. OPTIFLUX a300 C/i-DIV2.Flowmeter. XP-ANI / I /2/ABCD/T6 Ta = 65°C-8.30702.61 or 8.30702.62; NIFW; Type 4X, Type 6 DIP-ANI / 11, 111 /2/ FG /Ta = 65°C-8.30702.61 or 8.30702.62; NIFW; Type 4X, Type 6 For Entity Parameters and Nonincendive Field Wiring Parameters reference control drawings and drawing 8.30702.65 a =Type 1, 2, 4, 5, or 6 The OPTIFLUX a300 series flowmeter is the integration of the OPTIFLUX a000-DIV2 Primary Head and the model IFC 300 F(/i)-DIV2 VN304bcdefghijklmno Signal Converter. 3022275 Page 7 of 9 CFM pprouaIr Member of the FM Global Group Equipment Ratings: Explosionproof for use in Class I, Division 2, Groups A, B, C and D; Dust-Ignitionproof for use in Class II, III, Division 2, Groups F and G indoor/outdoor hazardous (classified) locations, utilizing Type 4X, 6, or 6P enclosure with intrinsically safe connections to Class I, II, III, Division 1, Group A, B, C, D, E, F and G hazardous (classified) locations. Temperature Class T6 Ta = 65°C Explosionproof for use in Class I, Division 2, Groups A, B, C and D; Dust-Ignitionproof for use in Class II, III, Division 2, Groups F and G indoor/outdoor hazardous (classified) locations, utilizing Type 4X, 6, or 6P enclosure with nonincendive field wiring connections to Class I, Il, III, Division 2, Group A, B, C, D, F and G hazardous (classified) locations. The examination was based on the installation of the apparatus being installed in accordance with control drawings 8.30702.61 or 8.30702.62. Temperature Class T6 Ta = 65°C FM Approved for: KROHNE Altometer Kerkeplaat 12, 3313 LC Dordrecht, the Netherlands 3022275 Page 8 of 9 <,"F.Upprovals- Vember of the FM Global Group This certifies that the equipment described has been found to comply with the following Approval Standards and other documents: Class 3600 2011 Class 3610 2010 Class 3611 2004 Class 3615 2006 Class 3810 2005 ANSI/IEC 60529 2004 ANSI/NEMA-250 1991 Original Project ID: 3022275 Approval Granted: January 3, 2005 Subsequent Revision Reports / Date Approval Amended Report Number Date Report Number Date 050228 March 11, 2005 050323 March 28, 2005 050715 July21, 2005 060724 August 25, 2006 060914 November 2, 2006 3026758 February 2, 2007 070209 April 11, 2007 071001 November 13, 2007 080314 March 24, 2008 080808 October 9, 2008 081028 November 20, 2008 090622 August 11, 2009 090824 September 3, 2009 100721 July 28, 2010 110803 January 30, 2012 3043360 February 14, 2012 FM Approvals LLC 0 u--64 14 February 2012 J.it. Marquedant Date Group Manager, Electrical 3022275 Page 9 of 9