Loading...
HomeMy WebLinkAboutAP_WATERFLUX 3070__en_OIML_120328__ Mi OIM L Certificate N° R49-1/2006-NL1-12.01 OIM L Member state Project number 11200810 The Netherlands Page 1 of 7 OI M L CERTI FI CATE OF CON FORM I TY Issuing authority Name: NMi Certin B.V. Address: Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands Applicant Name: KROHNEAltometer Address: Kerkeplaat 12 3313 LC Dordrecht The Netherlands Manufacturer of the certified type Name: KROHNEAltometer Address: Kerkeplaat 12 3313 LC Dordrecht The Netherlands Identification of certified type Type: WATERFLUX 3070 Water meter intended for the metering of cold potable water and hot water, model "WATERFLUX 3070", class 1 and 2. Further characteristics: see page 3 and further. This liabilit NMi Certin BV Thisdocument isissied under the provision that no liability is inderr Hugo de Grootplein 1,3314 EG Dordrecht accepted and that the applicant shall indemnify third-party PO Box 394,3300 AJ Dordrecht,N Ns\,L liability. Repro T+31 78 6332332 INSPECTIONF+31 78 6332309 Reproduction of the complete document is permitted. The r/17 be verer certin&mi.nl The notification of NM Certin as Issuing Authority can be uA I 1 LL www.nmi.nl verified at www.oiml.org. Mi OIM L Certificate N° R49-1/2006-NL1-12.01 Project number 11200810 Page 2of 7 This Certificate atteststhe conformity of the above identified type (represented by the sample or samples identified in the associated Test Report)with the requirementsof the following Recommendation of the International Organization of Legal Metrology (OIM L): R49-1/2006 (E): Metrological and technical requirements R49-2/2006 (E): Test methods R49-3/2006 (E): Test Report format This Certificate relatesonly to the metrological and technical characteristics of the type of instrument covered by the relevant OIM L Recommendation identified above. This Certificatedoesnot bestow any form of legal international approval. The conformity was established bythe resultsof testsand examinations provided in the associated Test Reports: - Number R49-1/2006-NL1-09.01 that includes41 pagesand 14 annexes; - Number R49-1/2006-NL1-10.01 that includes40 pagesand 3 annexes; - Number R49-1/2006-NL1-11.01 that includes40 pagesand 4 annexes; - Number R49-1.2006-NL1-12.01 that includes40 pagesand 3 annexes. The I*i,ng Authority NL1 NM ,ert' t; 28 March 2012 an ead rtification Board Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate isissued, partial quotation of the Certificate and of the associated Test Report is not permitted, although either may be reproduced in full. Mi OIM L Certificate N° R49-1/2006-NL1-12.01 Project number 11200810 Page 3 of 7 Identification of the certified pattern — continued from page 1 Water meter intended for metering cold potable water and hot water, based on an electromagnetic principle, designed to measure forward and reverse flow, with (minimum) 0 D straight inlet and outlet, with no flow conditioner and equipped with an electronic calculating/indicating device. Metrological characteristics: Type: WATERFLUX 3070 Meter size DN65 DN80 DN100 DN125 Minimum flow rate Q1 (m3/h) 0,40 0,625 0,64 1,0 1,0 1,56 1,60 Transitional flow rate Q2 (m3/h) 0,64 1,00 1,02 1,6 1,6 2,50 2,56 Permanent flow rate Q3 (m3/h) 100 100 160 160 250 250 400 Overload flow rate Q4 (m3/h) 125 125 200 200 312,5 312,5 500 Ratio Q3/Q1 250 160 250 160 250 160 250 Nominal diameter 65 80 100 125 (mm) Accuracy Class 1 Maximum admissible 16 pressure (bar) Min/max admissible temperature (°C) 0,1/50 Indicating range (m3) 99.999.999 Verification scale 0,0001 0,001 interval (m3) Orientation All positions Environmental class C Power supply Type Battery 3,6 V U battery Software versions 4.0.4 ; 4.0.10 ; 4.0.11 ; 4.0.12 ; 4.2.2 Mi OIM L Certificate N° R49-1/2006-NL1-12.01 Project number 11200810 Page 4 of 7 Meter size DN150 DN200 DN250 DN300 Minimum flow rate Q1 (m3/h) 2,50 2,52 3,94 6,25 10 Transitional flow rate Q2 (m3/h) 4,00 4,03 6,30 10 16 Permanent flow rate Q3 (m3/h) 400 630 630 1000 1600 Overload flow rate Q4 (m3/h) 500 787,5 787,5 1250 2000 Ratio Q3/Q1 160 250 160 160 160 Nominal diameter 150 200 250 300 (mm) Accuracy Class 1 Maximum admissible 16 10 pressure (bar) Min/max admissible 0,1 / 50 temperature (°C) Indicating range (m3) 99.999.999 Verification scale 0,001 0,01 interval (m3) Orientation All positions Environmental class C Power supply Type Battery 3,6 V U battery Software versions 4.0.4 ; 4.0.10 ; 4.0.11 ; 4.0.12 ; 4.2.2 Mi OIM L Certificate N° R49-1/2006-NL1-12.01 Project number 11200810 Page 5 of 7 Meter size DN25 DN40 DN50 DN65 Minimum flow rate 0,025 0,040 0,0625 0,100 0,100 0,1575 0,1575 0,250 Q1 (m3/h) Transitional flow rate 0,040 0,064 0,100 0,160 0,160 0,252 0,250 0,400 Q2 (m3/h) Permanent flow rate Q3 (m3/h) 10 16 25 40 40 63 63 100 Overload flow rate Q4 (m3/h) 12,5 20 31,3 50 50 78,75 78,75 125 Ratio Q3/Q1 400 400 400 400 Nominal diameter 25 40 50 65 (mm) Accuracy Class 2 Maximum admissible 16 pressure (bar) Min/max admissible temperature (°C) 0,1/50 Indicating range (m3) 99.999.999 Verification scale 0,00001 0,0001 interval (m3) Orientation All positions Environmental class C Power supply Type Battery 3,6 V U battery Software versions 4.0.4 ; 4.0.10 ; 4.0.11 ; 4.0.12 ; 4.2.2 Mi OIM L Certificate N° R49-1/2006-NL1-12.01 Project number 11200810 Page 6 of 7 Meter size DN80 DN100 DN125 DN150 Minimum flow rate 0,25 0,40 0,40 0,625 0,625 1,00 1,00 1,575 Q1 (m3/h) Transitional flow rate 0,40 0,64 0,64 1,00 1,00 1,60 1,60 2,52 Q2 (m3/h) Permanent flow rate Q3 (m3/h) 100 160 160 250 250 400 400 630 Overload flow rate Q4 (m3/h) 125 200 200 312,5 312,5 500 500 787,5 Ratio Q3/Q1 400 400 400 400 Nominal diameter 80 100 125 150 (mm) Accuracy Class 2 Maximum admissible 16 pressure (bar) Min/max admissible temperature (°C) 0,1/50 Indicating range (m3) 99.999.999 Verification scale 0,0001 0,001 interval (m3) Orientation All positions Environmental class C Power supply Type Battery 3,6 V U battery Software versions 4.0.4 ; 4.0.10 ; 4.0.11 ; 4.0.12 ; 4.2.2 Mi OIM L Certificate N° R49-1/2006-NL1-12.01 Project number 11200810 Page 7 of 7 Meter size DN200 DN250 DN300 Minimum flow rate Q1 (m3/h) 1,575 2,50 4,00 Transitional flow rate Q2 (m3/h) 2,52 4,00 6,40 Permanent flow rate Q3 (m3/h) 630 1000 1600 Overload flow rate Q4 (m3/h) 787,5 1250 2000 Ratio Q3/Q1 400 400 400 Nominal diameter 200 250 300 (mm) Accuracy Class 2 Maximum admissible 16 10 pressure (bar) Min/max admissible 0,1/50 temperature (°C) Indicating range (m3) 99.999.999 Verification scale 0,001 0,01 interval (m3) Orientation All positions Environmental class C Power supply Type Battery 3,6 V U battery Software versions 4.0.4_; 4.0.10— —; 4.0.11 ; 4.0.12—; 4.2.2