MA_OPTIFLUX 1000__en__110314_4000846301_R01
/ k M M 0 PTI FLUX 1000 Electromagnetic flow sensor in sandwich version The documentation is only complete when used in combination with the relevant documentation for the signal converter. ©KROHNE 03/2011-4000846301 -HB OPTI FLUX 1000 R01 en KROHNE ■ IMPRINT AIL rights reserved. It is prohibited to reproduce this documentation, or any part thereof,without the prior written authorisation of KROHNE Messtechnik GmbH. Subject to change without notice. Copyright 2011 by KROHNE Messtechnik GmbH - Ludwig-Krohne-Str. 5 - 47058 Duisburg (Germany) 2 www.krohne.com 03/2011 -4000846301 -HB OPTIFLUX 1000 R01 en CONTENTS 1 Safety instructions 5 1.1 Intended use ..................................................................................................................... 5 1.2 Certification ...................................................................................................................... 5 1.3 Safety instructions from the manufacturer..................................................................... 6 1.3.1 Copyright and data protection ................................................................................................6 1.3.2 Disclaimer...............................................................................................................................6 1.3.3 Product liability and warranty ................................................................................................7 1.3.4 Information concerning the documentation...........................................................................7 1.3.5 Warnings and symbols used...................................................................................................8 1.4 Safety instructions for the operator................................................................................. 8 2 Device description 9 2.1 Scope of delivery...............................................................................................................9 2.2 Device description .......................................................................................................... 10 2.3 Nameplates .................................................................................................................... 10 3 Installation 11 3.1 Notes on installation ...................................................................................................... 11 3.2 Storage ........................................................................................................................... 11 3.3 Transport ........................................................................................................................ 11 3.4 Installation conditions.................................................................................................... 12 3.4.1 Inlet and outlet...................................................................................................................... 12 3.4.2 Mounting position.................................................................................................................. 12 3.4.3 Flange deviation.................................................................................................................... 13 3.4.4 T-section ............................................................................................................................... 13 3.4.5 Vibration................................................................................................................................ 13 3.4.6 Magnetic field........................................................................................................................ 14 3.4.7 Bends .................................................................................................................................... 14 3.4.8 Open discharge ..................................................................................................................... 15 3.4.9 Control valve ......................................................................................................................... 15 3.4.10 Air venting ........................................................................................................................... 15 3.4.1 1 Pump ................................................................................................................................... 16 3.4.12 Temperatures ..................................................................................................................... 16 3.5 Mounting......................................................................................................................... 17 3.5.1 Torques and pressures......................................................................................................... 17 4 Electrical connections 19 4.1 Safety instructions.......................................................................................................... 19 4.2 Grounding ....................................................................................................................... 19 4.3 Virtual reference for IFC 300 (C, W and F version) ........................................................ 20 4.4 Connection diagrams ..................................................................................................... 20 5 Service 21 5.1 Spare parts availability................................................................................................... 21 03/2011-4000846301-HB OPTIFLUX 1000 R01 en www.krohne.com 3 CONTENTS 5.2 Availability of services.................................................................................................... 21 5.3 Returning the device to the manufacturer..................................................................... 21 5.3.1 General information.............................................................................................................. 21 5.3.2 Form (for copying) to accompany a returned device............................................................ 22 5.4 Disposal .......................................................................................................................... 22 6 Technical data 23 6.1 Measuring principle........................................................................................................ 23 6.2 Technical data................................................................................................................. 24 6.3 Dimensions and weights ................................................................................................ 28 6.4 Measuring accuracy ....................................................................................................... 30 7 Notes 31 4 www.krohne.com 03/2011-4000846301-HB OPTIFLUX 1000 R01 en [PTIFLUX 1000 SAFETY INSTRUCTIONS 0 1 .1 Intended use The OPTIFLUX 1000 flowmeter measures the volumetric flow rate of electrically conductive liquids, acids, alkaline solutions, pastes and slurries, also with very high solid contents. 1 .2 Certification C E The device fulfils the statutory requirements of the following EC directives: • EMC Directive 2004/108/EC in conjunction with EN 61326-1: 2006 • Low Voltage Directive 2006/95/EC in conjunction with EN 61010-1: 2001 • Pressure Equipment Directive 97/23/EC The manufacturer certifies successful testing of the product by applying the CE marking. 03/2011 -4000846301 -HB OPTIFLUX 1000 R01 en www.krohne.com 5 H SAFETY INSTRUCTIONS 0 1 .3 Safety instructions from the manufacturer 1.3.1 Copyright and data protection The contents of this document have been created with great care. Nevertheless, we provide no guarantee that the contents are correct, complete or up-to-date. The contents and works in this document are subject to copyright. Contributions from third parties are identified as such. Reproduction, processing, dissemination and any type of use beyond what is permitted under copyright requires written authorisation from the respective author and/or the manufacturer. The manufacturer tries always to observe the copyrights of others, and to draw on works created in-house or works in the public domain. The collection of personal data (such as names, street addresses or e-mail addresses) in the manufacturer's documents is always on a voluntary basis whenever possible. Whenever feasible, it is always possible to make use of the offerings and services without providing any personal data. We draw your attention to the fact that data transmission over the Internet (e.g.when communicating by e-mail) may involve gaps in security. It is not possible to protect such data completely against access by third parties. We hereby expressly prohibit the use of the contact data published as part of our duty to publish an imprint for the purpose of sending us any advertising or informational materials that we have not expressly requested. 1.3.2 Disclaimer The manufacturer will not be liable for any damage of any kind by using its product, including, but not limited to direct, indirect or incidental and consequential damages. This disclaimer does not apply in case the manufacturer has acted on purpose or with gross negligence. In the event any applicable law does not allow such limitations on implied warranties or the exclusion of limitation of certain damages, you may, if such law applies to you, not be subject to some or all of the above disclaimer, exclusions or limitations. Any product purchased from the manufacturer is warranted in accordance with the relevant product documentation and our Terms and Conditions of Sale. The manufacturer reserves the right to alter the content of its documents, including this disclaimer in anyway, at any time,for any reason,without prior notification,and will not be liable in anyway for possible consequences of such changes. 6 www.krohne.com 03/2011 -4000846301 -HB OPTIFLUX 1000 R01 en SAFETY INSTRUCTIONS 0 1.3.3 Product liability and warranty The operator shall bear responsibility for the suitability of the device for the specific purpose. The manufacturer accepts no liability for the consequences of misuse by the operator. Improper installation and operation of the devices (systems)will cause the warranty to be void. The respective "Standard Terms and Conditions"which form the basis for the sales contract shall also apply. 1.3.4 Information concerning the documentation To prevent any injury to the user or damage to the device it is essential that you read the information in this document and observe applicable national standards, safety requirements and accident prevention regulations. If this document is not in your native language and if you have any problems understanding the text, we advise you to contact your local office for assistance. The manufacturer can not accept responsibility for any damage or injury caused by misunderstanding of the information in this document. This document is provided to help you establish operating conditions, which will permit safe and efficient use of this device. Special considerations and precautions are also described in the document, which appear in the form of underneath icons. 03/2011 -4000846301 -HB OPTIFLUX 1000 R01 en www.krohne.com J U SAFETY INSTRUCTIONS 1.3.5 Warnings and symbols used Safety warnings are indicated by the following symbols. QDANGER! This information refers to the immediate danger when working with electricity. DANGER! SSS This warning refers to the immediate danger of burns caused by heat or hot surfaces. DANGER! EX This warning refers to the immediate danger when using this device in a hazardous atmosphere. A DANGER! These warnings must be observed without fail. Even partial disregard of this warning can lead to serious health problems and even death. There is also the risk of seriously damaging the device or parts of the operators plant. WARNING! A! Disregarding this safety warning, even if only in part,poses the risk of serious health problems. There is also the risk of damaging the device orparts of the operators plant. QCA regard ° Disregarding these instructions can result in damage to the device or to parts of the operator's plant. a /NFORMA T/ON! 1 These instructions contain important information for the handling of the device. ® LEGAL NOTICE! This note contains information on statutory directives and standards. HANDLING This symbol designates all instructions for actions to be carried out by the operator in the specified sequence. RESULT This symbol refers to all important consequences of the previous actions. 1 .4 Safety instructions for the operator WARNING! A! In general, devices from the manufacturer may only be installed, commissioned, operated and maintained by properly trained and authorized personnel. This document is provided to help you establish operating conditions, which will permit safe and efficient use of this device. 8 www.krohne.com 03/2011 -4000846301 -HB OPTIFLUX 1000 R01 en DEVICE DESCRIPTION p 2.1 Scope of delivery a /NFORMA T/ON! Check the packing list to check if you received completely all that you ordered. a /NFORMA T/ON! 1 Inspect the cartons carefully for damage or signs of rough handling. Report damage to the carrier and to the local office of the manufacturer. a /NFORMA T/ON! The device will arrive in two cartons. One carton contains the converter and one carton contains the sensor. O O O O © OO Figure 2-1:Scope of delivery 1� Ordered flowmeter 2� Product documentation 3� Factory calibration report 4� CD-ROM with product documentation 5� Grounding rings(optionally) © Signal cable(optionally,remote versions only) a /NFORMA T/ON! Assembly materials and tools are not part of the delivery. Use the assembly materials and tools in compliance with the applicable occupational health and safety directives. 03/2011 -4000846301 -HB OPTIFLUX 1000 R01 en www.krohne.com 9 p DEVICE DESCRIPTION OPTIFLUX 1000 2.2 Device description Your measuring device is supplied ready for operation. The factory settings for the operating data have been made in accordance with your order specifications. The following versions are available: • Compact version (the signal converter is mounted directly on the measuring sensor) • Remote version (electrical connection to the measuring sensor via field current and signal cable) O 00 1� Remote version 2� Compact version with IFC 300 signal converter 3Z Compact version with IFC 100(01 signal converter 4� Compact version with IFC 100(451 signal converter 2.3 Nameplates a /NFORMA T/ON! 1 Look at the device nameplate to ensure that the device is delivered according to your order: Check for the correct supply voltage printed on the nameplate. 10 KR O H N E NIL 3313 LC Dordrecht OPTIFLUX 1000 O5/N:Axxxxxxx Manufactured:20XX C E 00311 GK=2.714 GKL=5.123 DN:150mm/6 inch PED(97/23/EC): O r12 16 bar @ TS 1<=80°C Wetted materials: PFA 14bar@TS2 =120°C IP 66/67 HC4 24 bar@TT =20°C O 1� Name and address of the manufacturer 2� Type designation of the flowmeter and CE sign with number(s)of notified body/bodies 3Z Calibration data 4� PED data 10 www.krohne.com 03/2011 -4000846301 -HB OPTIFLUX 1000 R01 en INSTALLATION 3.1 Notes on installation a /NFORMA T/ON! Inspect the cartons carefully for damage or signs of rough handling. Report damage to the carrier and to the local office of the manufacturer. a /NFORMA T/ON! iCheck the packing list to check if you received completely all that you ordered. a /NFORMA T/ON! Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. 3.2 Storage • Store the device in a dry and dust-free location. • Avoid lasting direct exposure to the sun. • Store the device in its original packing. 3.3 Transport r � O 4/w/ Figure 3-1:Transport 03/2011-4000846301-HB OPTIFLUX 1000 R01 en www.krohne.com 11 INSTALLATION 3.4 Installation conditions 3.4.1 Inlet and outlet 10 02 Figure 3-2:Recommended inlet and outlet 1Q >_5DN © >_2DN 3.4.2 Mounting position Figure 3-3:Mounting position 12 www.krohne.com 03/2011-4000846301-HB OPTIFLUX 1000 R01 en INSTALLATION 3.4.3 Flange deviation A CAUTION! Max.permissible deviation of pipe flange faces: Lmax- Lmin <0.5mm/0.027=== - Figure 3-4:Flange deviation q) Amax (Z Amin 3.4.4 T-section 10 Figure 3-5:Distance after T-sections 9) >_10 DN 3.4.5 Vibration Figure 3-6:Avoid vibrations 03/2011-4000846301-HB OPTIFLUX 1000 R01 en www.krohne.com 13 INSTALLATION 3.4.6 Magnetic field E:WT Figure 3-7:Avoid magnetic fields 3.4.7 Bends �I Figure 3-8:Installation in bending pipes Y Figure 3-9:Installation in bending pipes 14 www.krohne.com 03/2011-4000846301-HB OPTIFLUX 1000 R01 en INSTALLATION 3.4.8 Open discharge Figure 3-10:Installation before an open discharge 3.4.9 Control valve Figure 3-11:Installation before control valve 3.4.10 Air venting O O Figure 3-12:Air venting (1) >_5m ® Airventilation point 03/2011-4000846301-HB OPTIFLUX 1000 R01 en www.krohne.com 15 INSTALLATION 3.4.11 Pump Figure 3-13:Installation after pump 3.4.12 Temperatures A CAUTION! Protect the device from direct sunlight. Temperature range Process ['C] Ambient UC] Process UF] Ambient PH min. max. min. max. min. max. min. max. Separate flow sensor -25 120 -25 65 -13 248 -13 149 Compact+ IFC 300 C -25 120 -25 65 -13 248 -13 149 Compact+ IFC 100 C -25 120 -25 65 -13 248 -13 149 16 www.krohne.com 03/2011-4000846301-HB OPTIFLUX 1000 R01 en INSTALLATION 3.5 Mounting 3.5.1 Torques and pressures o Figure 3-14:Tightening of bolts © Tightening of bolts (1) Step 1:Apply approx. 50% of max. torque given in table. Step 2:Apply approx. 80% of max. torque given in table. Step 3: Apply 100% of max. torque given in table. EN 1092-1 Nominal size Pipe flanges Pressure rating Max. torque [bar] [Nm] Flange size Pressure rating DN10 DN15 PN 16/40 16 16 DN15 DN15 PN 16/40 16 16 DN25 DN25 PN 16/40 16 16 DN40 DN40 PN 16/40 16 25 DN50 DN50 PN 16/40 16 45 DN80 DN80 PN 16/40 16 25 DN100 DN100 PN 16/40 16 33 DN150 DN150 PN 16/40 16 82 03/2011-4000846301-HB OPTIFLUX 1000 R01 en www.krohne.com 17 INSTALLATION ASME B 16.5 Nominal size Pipe flanges Pressure rating Max. torque [psig] [Nm] Flange size Pressure rating 3/8" 1/2" 150/300 Lb 230 16 1/2" 1/2" 150/300 Lb 230 16 1" 150/300 Lb 15 1 1/2" 1 1/2" 150/300 Lb 230 25 2" 2" 150/300 Lb 230 45 3" 3" 150 Lb 230 56 3" 3" 300Lb 230 28 4" 4" 150/300 Lb 230 36 6" 6" 150Lb 230 100 6" 6" 300Lb 230 66 18 www.krohne.com 03/2011-4000846301-HB OPTIFLUX 1000 R01 en ELECTRICAL CONNECTIONS p 4.1 Safety instructions QDANGER! All work on the electrical connections may only be carried out with the power disconnected. Take + note of the voltage data on the nameplate! QOA Observe Obseerve the national regulations for electrical installations! WARNING! without fail the local occupational health and safety regulations.Any work done on the ' electrical components of the measuring device may only be carried out by properly trained specialists. a /NFORMA T/ON! Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. 4.2 Grounding QDANGER! The device must be grounded in accordance with regulations in order to protect personnel + against electric shocks. 10 02 I L Figure 4-1:Grounding 1� Metal pipelines,not internally coated.Grounding without grounding rings! 2� Metal pipelines with internal coating and non-conductive pipelines.Grounding with grounding rings! r: 0 Figure 4-2:Grounding ring number 1 Grounding ring number 1 (Optional for DN25...100): • 3 mm/0.1" thick (tantalum: 0.5 mm/0.11 03/2011 -4000846301 -HB OPTIFLUX 1000 R01 en www.krohne.com 19 0 ELECTRICAL CONNECTIONS M 4.3 Virtual reference for IFC 300 (C, W and F version) Figure 4-3:Virtual reference Possible if: • >_ DN10 • Electrical conductivity>_ 200 PS/cm • Electrode cable max. 50m., type DS 4.4 Connection diagrams a /NFORMA T/ON! 1 For the connection diagrams please refer to the documentation of the applicable converter. 20 www.krohne.com 03/2011-4000846301-HB OPTIFLUX 1000 R01 en III I SERVICE19 5.1 Spare parts availability The manufacturer adheres to the basic principle that functionally adequate spare parts for each device or each important accessory part will be kept available for a period of 3 years after delivery of the last production run for the device. This regulation only applies to spare parts which are subject to wear and tear under normal operating conditions. 5.2 Availability of services The manufacturer offers a range of services to support the customer after expiration of the warranty. These include repair, maintenance, technical support and training. a /NFORMA T/ON! For more precise information,please contact your local representative. 5.3 Returning the device to the manufacturer 5.3.1 General information This device has been carefully manufactured and tested. If installed and operated in accordance with these operating instructions, it will rarely present any problems. A CAUTION! Shouldyou nevertheless need to return a device for inspection or repair,please pay strict attention to the following points: • Due to statutory regulations on environmental protection and safeguarding the health and safety of our personnel, manufacturer may only handle, test and repair returned devices that have been in contact with products without risk to personnel and environment. • This means that the manufacturer can only service this device if it is accompanied by the following certificate(see next sectionl confirming that the device is safe to handle. If the device Aog if the device has been operated with toxic, caustic, flammable or water-endangering products, you are kindly requested: • to check and ensure, if necessary by rinsing or neutralizing, that all cavities are free from such dangerous substances, • to enclose a certificate with the device confirming that is safe to handle and stating the product used. 03/2011 -4000846301 -HB OPTIFLUX 1000 R01 en www.krohne.com 21 SERVICE 5.3.2 Form (for copying) to accompany a returned device Company: Address: Department: Name: Tel. no.: Fax no.: Manufacturer's order no.or serial no.: The device has been operated with the following medium: This medium is: water-hazardous toxic caustic flammable We checked that all cavities in the device are free from such substances. We have flushed out and neutralized all cavities in the device. We hereby confirm that there is no risk to persons or the environment through any residual media contained in the device when it is returned. Date: Signature: Stamp: 5.4 Disposal A CA UT/ON! Disposal must be carried out in accordance with legislation applicable in your country. 22 www.krohne.com 03/2011-4000846301-HB OPTIFLUX 1000 R01 en TECHNICAL DATA p 6.1 Measuring principle An electrically conductive fluid flows inside an electrically insulated pipe through a magnetic field. This magnetic field is generated by a current, flowing through a pair of field coils. Inside of the fluid, a voltage U is generated: U =v* k* B * D in which: v= mean flow velocity k=factor correcting for geometry B = magnetic field strength D = inner diameter of flow meter The signal voltage U is picked off by electrodes and is proportional to the mean flow velocity v and thus the flow rate q. A signal converter is used to amplify the signal voltage, filter it and convert it into signals for totalising, recording and output processing. 3 2 4 1 9) Induced voltage(proportional to flow velocity) 2� Electrodes 3Z Magnetic field 4� Field coils 03/2011 -4000846301 -HB OPTIFLUX 1000 R01 en www.krohne.com 23 TECHNICAL DATA OPTIFLUX 1000 6.2 Technical data /NFORMA T/ON! 1-14-1 • The following data is provided for general applications. lfyou require data that is more relevant to your specific application,please contact us oryour local representative. • Additional information(certificates, special tools, software,...]and complete product documentation can be downloaded free of charge from the website(Download Center]. Measuring system Measuring principle Faraday's law of induction Application range Electrically conductive fluids Measured value Primary measured value Flow velocity Secondary measured value Volume flow, mass flow,electrical conductivity,coil temperature Design Features Sandwich version Modular construction The measurement system consists of a flow sensor and a signal converter. It is available as compact and as separate version. More information about the signal converter can be found in the documentation of the signal converter. Compact version With IFC 100 converter: OPTIFLUX 1100 C With IFC 300 converter: OPTIFLUX 1300 C Remote version In wall(W) mount version with IFC 100 converter: OPTIFLUX 1100 W In field (F),wall(W)or rack(R) mount version with IFC 300 converter: OPTIFLUX 1300 F,W or R Nominal diameter DN10...150/3/8...6" Measurement range -12...+12 m/s/-40...+40 ft/s 24 www.krohne.com 03/2011-4000846301-HB OPTIFLUX 1000 R01 en TECHNICAL DATA Measuring accuracy Reference conditions Flow condition simular to EN 29104 Medium:Water Electrical conductivity:>_300 µS/cm Temperature:+10...+30°C/+50...+86°F Flow velocity: > 1 m/s/>3 ft/s Operating pressure: 1 bar/14.5 psig Wet calibrated on EN 17025 accredited calibration rig by direct volume comparison. Maximum measuring error Related to volume flow(MV= Measured Value) These values are related to the pulse/frequency output. The additional typical measuring deviation for the current output is ±10 µA. For information refer to Measuring accuracyon page 30. Repeatability ±0.1%of MV, minimum 1 mm/s Long term stability ±0.1%of MV Special calibration On request Operating conditions Temperature Process temperature -25...+120°C/-13...+248°F Maximum temperature change 120°C/248°F (shock) Ambient temperature -25...+65°C/-13...+149°F Storage temperature -50...+70°C/-58...+158°F Pressure Ambient pressure Atmospheric Nominal flange pressure Standard: EN 1092-1 DN100... DN150: PN 16 DN10...80: PN 40 ASME B16.5 Standard: 3/8...6": 150 lb RF Option: 3/8...4":300 Lb RF JIS DN10...100/3/8...4": 20 K DN150/6": 10 K Vacuum load 0 mbar/0 psi absolute Pressure ranges for secondary Pressure resistant up to 40 bar/580 psi containment Burst pressure up to approx. 160 bar/2320 psi 03/2011-4000846301-HB OPTIFLUX 1000 R01 en www.krohne.com 25 TECHNICAL DATA Chemical properties Physical condition Liquids Electrical conductivity Non water: >_5 µS/cm Water: >_20 µS/cm Permissible gas content IFC 1 00:<_3% (volume) IFC 300:<_5% Permissible solid content IFC 100:<_ 10% (volume) IFC 300:<_70% Recommended flow velocity -12...+12 m/s/-40...+40 ft/s Installation condtitions Installation Take care that flow sensor always fully filled. For information refer to Installation on page 11. Flow direction Forward and reverse Arrow on flow sensor indicates positive flow direction. Inlet run >_5 DN (without disturbing flow,after a single 90' bend) >10 DN (after a double bend 2x 90°1 >10 DN (behind a control valve) Outlet run >2 DN Dimensions and weights For information refer to Dimensions and weightson page 28. Materials Sensor housing DN10...40:GTW-S 38 DN50...150:sheet steel Measuring tube PFA Connection box Die-cast aluminium (polyurethane coated) Option:stainless steel Measuring electrodes Hastelloy C4 Grounding rings DN10...15: Integrated stainless steel 316(1.4571) (AISI 316 TO DN25...150:Separate stainless steel 316(1.4571) (AISI 316 TO Grounding rings can be omitted with virtual reference option for the IFC 300 converter. Stud bolts and nuts DN40...150: rubber centering sleeves Option:steel,stainless steel Process connections EN 1092-1 DN10...150 in PN 16...40 ASME 3/8...6" in 150...300 lb JIS DN10...150 in JIS 10...20 K 26 www.krohne.com 03/2011-4000846301-HB OPTIFLUX 1000 R01 en 11 TECHNICAL DATA Electrical connections Signal cable Only for remote systems Type A Standard cable, double shielded. Max. length:600 m/1950 ft(dep.on electrical conductivity and measuring sensor).See documentation of the converter for more information. Type B Optional cable,triple shielded. Max. length:600 m/1950 ft(dep.on electrical conductivity and measuring sensor).See documentation of the converter for more information. Approvals and certifications CE This device fulfills the statutory requirements of the EC directives. The manufacturer certifies successful testing of the product by applying the CE mark. Electromagnetic compatibility Directive:2004/108/EC and A1,A2 NAMUR NE21/04 Harmonized standard: EN 61326-1 : 2006 Low Voltage Directive Directive: 2006/95/EC Harmonized standard: EN 61010 :2001 Pressure Equipment Directive Directive:97/23/EC Category I, II or SEP Fluid group 1 Production module H Other approvals and standards Protection category acc.to Standard: IP 66/67(NEMA 4/4X/61 IEC 529/EN 60529 Optional: IP 68(NEMA 6P) Vibration test IEC 68-2-6 03/2011-4000846301-HB OPTIFLUX 1000 R01 en www.krohne.com 27 TECHNICAL DATA 6.3 Dimensions and weights Remote version a=77 mm/3.1" b c b= 139mm/5.5" 1Q c= 106mm/4.2" a0 Total height= H+a H Lx� W Compact version with b C a= 155 mm/6.1" IFC300 b=230mm/9.1" 1Q ja O c=260 mm/10.2" O Total height= H+a H L W Compact version with a=82 mm/3.2" IFC 100 1001 c b b= 161 mm 6.3" a o;o O c=257mm/10.1 Total height= H+a -- - H Lt W Compact version with b a= 186 mm/7.3" IFC 100 1450) b= 161 mm/6.3" a c= 184mm/2.7" 1Q Total height= H+a - - - - H L W 1Q The value may vary depending on the used cable glands. a /NFORMA T/ON! • All data given in the following tables are based on standard versions of the sensor only. • Especially for smaller nominal sizes of the sensor, the converter can be bigger than the sensor. • Note that for other pressure ratings than mentioned, the dimensions may be different. • For full information on converter dimensions see relevant documentation. 28 www.krohne.com 03/2011-4000846301-HB OPTIFLUX 1000 R01 en TECHNICAL DATA p Nominal size Dimensions [mm] Approx.weight DN PN [bar] L H W [kg] 10 40 68 137 47 1.7 15 40 68 137 47 1.7 25 40 54 147 66 1.7 40 40 78 162 82 2.6 50 40 100 151 101 4.2 80 40 150 180 130 5.7 100 200 207 156 10.5 150 116!�E 200 271 219 15.0 Nominal size Dimensions [inches] Approx.weight [lb] ASME PN [psi] L H W Nor- 3/8" 580 2.68 5.39 1.85 3.7 '/2" 580 2.68 5.39 1.85 3.7 580 2.13 5.79 2.6 3.7 1'/2" 580 3.07 6.38 3.23 5.7 2" 580 3.94 5.94 3.98 9.3 3" 580 5.91 7.08 5.12 12.6 4" 232 7.87 8.15 6.14 23.1 6" 232 7.87 10.67 8.62 33.1 A CAUTION! • Pressures are applicable at2LTC/68°F. • For higher temperatures, the pressure ratings are as perASMEB16.5(uo to 247. 03/2011-4000846301-HB OPTIFLUX 1000 R01 en www.krohne.com 29 TECHNICAL DATA 6.4 Measuring accuracy Reference conditions • Medium: water • Temperature: 20°C/68°F • Pressure: 1 bar/ 14.5 psi Y[%] 1.1 1.0 0.9 0.8 0.7 0.6 0.5 �Zz0.4 Q2 0.3 0.2 0.1 0 1 2 3 4 5 6 7 8 9 10 11 12 X [m/sl X[m/sl:flow velocity Y[%]:deviation from the actual measured value(mv) Compact with IFC 300 Accuracy Curve DN 10...150/3/8...6" 0.3%of my+2 mm/s 1T Compact with IFC 100 Accuracy Curve DN10...150/3/8...6" 0.4%of my+ 1 mm/s 2z 30 www.krohne.com 03/2011-4000846301-HB OPTIFLUX 1000 R01 en NOTES A 03/2011-4000846301-HB OPTIFLUX 1000 R01 en www.krohne.com 31 r� r . rti,y • •• M• • • •• AW to ri KROHNE product overview • Electromagnetic flowmeters • Variable area flowmeters • Ultrasonic flowmeters 0 • Mass flowmeters 0 • Vortex flowmeters L 3 • Flow controllers v • Level meters L U s • Temperature meters • Pressure meters v • Analysis products • Measuring systems for the oil and gas industry 0 • Measuring systems for sea-going tankers X LL LL H a 0 m Head Office KROHNE Messtechnik GmbH Ludwig-Krohne-Str. 5 D-47058 Duisburg (Germany) 0 Tel.:+49 (0)203 301 0 M Fax:+49 (0)203 301 10389 0 Z infofdkrohne.de & The current list of all KROHNE contacts and addresses can be found at: KROHNE Y o www.krohne.com