Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MA_OPTIFLUX 5000_SW_en__090902_4000686201_R01
/ , M 0 PTI FLUX 5000 Electromagnetic flowmeter in sandwich version The documentation is only complete when used in combination with the relevant documentation for the converter. KROHNE ©KROHNE 09/2009-4000686201-R01-SW-en ■ IMPRINT All rights reserved. It is prohibited to reproduce this documentation, or any part thereof,without the prior written authorisation of KROHNE Messtechnik GmbH & Co. KG. Subject to change without notice. Copyright 2009 by KROHNE Messtechnik GmbH & Co. KG - Ludwig-Krohne-StraBe 5 - 47058 Duisburg 2 www.krohne.com 09/2009-4000686201-R01-SW-en CONTENTS 1 Safety instructions 1.1 Intended use ..................................................................................................................... 5 1.2 Safety instructions from the manufacturer..................................................................... 5 1.2.1 Copyright and data protection ................................................................................................5 1.2.2 Disclaimer...............................................................................................................................5 1.2.3 Product liability and warranty ................................................................................................6 1.2.4 Information concerning the documentation...........................................................................6 1.2.5 Warnings and symbols used................................................................................................... 7 1.3 Safety instructions for the operator................................................................................. 7 2 Device description 8 2.1 Scope of delivery...............................................................................................................8 2.2 Nameplates ......................................................................................................................8 3 Installation 9 3.1 Notes on installation ........................................................................................................ 9 3.2 Storage ............................................................................................................................. 9 3.3 Transport.......................................................................................................................... 9 3.4 Installation conditions.................................................................................................... 10 3.4.1 Inlet and outlet...................................................................................................................... 10 3.4.2 Mounting position.................................................................................................................. 10 3.4.3 Flange deviation.................................................................................................................... 11 3.4.4 T-section ............................................................................................................................... 11 3.4.5 Vibration................................................................................................................................ 11 3.4.6 Magnetic field........................................................................................................................ 12 3.4.7 Bends .................................................................................................................................... 12 3.4.8 Open discharge ..................................................................................................................... 13 3.4.9 Control valve ......................................................................................................................... 13 3.4.10 Air venting ........................................................................................................................... 13 3.4.1 1 Pump ................................................................................................................................... 14 3.5 Mounting......................................................................................................................... 14 3.5.1 Torques and pressure........................................................................................................... 14 4 Electrical connections 16 4.1 Safety instructions.......................................................................................................... 16 4.2 Grounding ....................................................................................................................... 16 4.3 Virtual reference for IFC 300 (C, W and F version) ........................................................ 17 09/2009-4000686201-R01-SW-en www.krohne.com 3 ■ CONTENTS 5 Service 18 5.1 Spare parts availability................................................................................................... 18 5.2 Availability of services.................................................................................................... 18 5.3 Returning the device to the manufacturer..................................................................... 18 5.3.1 General information.............................................................................................................. 18 5.3.2 Form (for copying) to accompany a returned device............................................................ 19 5.4 Disposal.......................................................................................................................... 19 6 Technical data 20 6.1 Measuring principle........................................................................................................ 20 6.2 Technical data................................................................................................................. 21 6.3 Dimensions and weights ................................................................................................ 26 4 www.krohne.com 09/2009-4000686201-R01-SW-en SAFETY INSTRUCTIONS O 1 .1 Intended use The flow meter measures the volumetric flow rate of electrically conductive liquids, acids, alkaline solutions, pastes and slurries, also with very high solid contents. It can be combined with an IFC 100 or an IFC 300electromagnetic signal converter. 1 .2 Safety instructions from the manufacturer 1.2.1 Copyright and data protection The contents of this document have been created with great care. Nevertheless, we provide no guarantee that the contents are correct, complete or up-to-date. The contents and works in this document are subject to German copyright. Contributions from third parties are identified as such. Reproduction, processing, dissemination and any type of use beyond what is permitted under copyright requires written authorisation from the respective author and/or the manufacturer. The manufacturer tries always to observe the copyrights of others, and to draw on works created in-house or works in the public domain. The collection of personal data (such as names, street addresses or e-mail addresses) in the manufacturer's documents is always on a voluntary basis whenever possible. Whenever feasible, it is always possible to make use of the offerings and services without providing any personal data. We draw your attention to the fact that data transmission over the Internet (e.g.when communicating by e-mail) may involve gaps in security. It is not possible to protect such data completely against access by third parties. We hereby expressly prohibit the use of the contact data published as part of our duty to publish an imprint for the purpose of sending us any advertising or informational materials that we have not expressly requested. 1.2.2 Disclaimer The manufacturer will not be liable for any damage of any kind by using its product, including, but not limited to direct, indirect, incidental, punitive and consequential damages. This disclaimer does not apply in case the manufacturer has acted on purpose or with gross negligence. In the event any applicable law does not allow such limitations on implied warranties or the exclusion of limitation of certain damages, you may, if such law applies to you, not be subject to some or all of the above disclaimer, exclusions or limitations. Any product purchased from the manufacturer is warranted in accordance with the relevant product documentation and our Terms and Conditions of Sale. The manufacturer reserves the right to alter the content of its documents, including this disclaimer in any way, at any time,for any reason,without prior notification,and will not be liable in any way for possible consequences of such changes. 09/2009-4000686201-R01-SW-en www.krohne.com 5 H SAFETY INSTRUCTIONS 1.2.3 Product liability and warranty The operator shall bear responsibility for the suitability of the device for the specific purpose. The manufacturer accepts no liability for the consequences of misuse by the operator. Improper installation and operation of the devices (systems)will cause the warranty to be void. The respective "Standard Terms and Conditions"which form the basis for the sales contract shall also apply. 1.2.4 Information concerning the documentation To prevent any injury to the user or damage to the device it is essential that you read the information in this document and observe applicable national standards, safety requirements and accident prevention regulations. If this document is not in your native language and if you have any problems understanding the text, we advise you to contact your local office for assistance. The manufacturer can not accept responsibility for any damage or injury caused by misunderstanding of the information in this document. This document is provided to help you establish operating conditions, which will permit safe and efficient use of this device. Special considerations and precautions are also described in the document, which appear in the form of underneath icons. 6 www.krohne.com 09/2009-4000686201-R01-SW-en SAFETY INSTRUCTIONS 0 1.2.5 Warnings and symbols used Safety warnings are indicated by the following symbols. QDANGER! This information refers to the immediate danger when working with electricity. DANGER! SSS This warning refers to the immediate danger of burns caused by heat or hot surfaces. DANGER! EX This warning refers to the immediate danger when using this device in a hazardous atmosphere. A DANGER! These warnings must be observed without fail. Even partial disregard of this warning can lead to serious health problems and even death. There is also the risk of seriously damaging the device or parts of the operators plant. WARNING! A! Disregarding this safety warning, even if only in part,poses the risk of serious health problems. There is also the risk of damaging the device or parts of the operator's plant. QCA regard ° Disregarding these instructions can result in damage to the device or to parts of the operator's plant. a /NFORMA T/ON! 1 These instructions contain important information for the handling of the device. ® LEGAL NOTICE! This note contains information on statutory directives and standards. HANDLING This symbol designates all instructions for actions to be carried out by the operator in the specified sequence. RESULT This symbol refers to all important consequences of the previous actions. 1 .3 Safety instructions for the operator WARNING! A! In general, devices from the manufacturer may only be installed, commissioned, operated and maintained by properly trained and authorized personnel. This document is provided to help you establish operating conditions, which will permit safe and efficient use of this device. 09/2009-4000686201-R01-SW-en www.krohne.com J DEVICE DESCRIPTION 2.1 Scope of delivery 00 0 1� Remote version (2) Compact version with IFC 300 signal converter Q3 Compact version with IFC 100(01 signal converter 4� Compact version with IFC 100(451 signal converter (1) 0 (2) (4) o O ram r c ANNEW bi �5 Figure 2-1:Scope of delivery 1Q Ordered flowmeter (2) Quick Start Z3 Factory calibration report 4Q CD-ROM with product documentation 5� Grounding rings(optionally) © Cable(remote versions only) 2.2 Nameplates /NFORMA T/ON! 1-116] Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. 8 www.krohne.com 09/2009-4000686201-R01-SW-en INSTALLATION 3.1 Notes on installation a /NFORMA T/ON! Inspect the cartons carefully for damage or signs of rough handling. Report damage to the carrier and to the local office of the manufacturer. a /NFORMA T/ON! iCheck the packing list to check if you received completely all that you ordered. a /NFORMA T/ON! Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. 3.2 Storage • Store the device in a dry and dust-free location. • Avoid lasting direct exposure to the sun. • Store the device in its original packing. 3.3 Transport KI O Figure 3-1:Transport 09/2009-4000686201-R01-SW-en www.krohne.com 9 INSTALLATION 3.4 Installation conditions 3.4.1 Inlet and outlet 10 02 Figure 3-2:Recommended inlet and outlet 1Q >_5DN © >_2DN 3.4.2 Mounting position Figure 3-3:Mounting position 10 www.krohne.com 09/2009-4000686201-R01-SW-en INSTALLATION p 3.4.3 Flange deviation A CAUTION! Max.permissible deviation of pipe flange faces: Lmax-Lmin—<0.5mm/0.02" I ------------------------------------- -- ------- Figure 3-4:Flange deviation Amax T Amin 3.4.4 T-section ;L 10 Figure 3-5:Distance after T-sections 1� >_10 DN 3.4.5 Vibration Figure 3-6:Avoid vibrations 09/2009-4000686201-R01-SW-en www.krohne.com 11 INSTALLATION 3.4.6 Magnetic field Figure 3-7:Avoid magnetic fields 3.4.7 Bends Figure 3-8:Installation in bending pipes Figure 3-9:Installation in bending pipes 12 www.krohne.com 09/2009-4000686201-R01-SW-en INSTALLATION 3.4.8 Open discharge Figure 3-10:Installation before an open discharge 3.4.9 Control valve Figure 3-11:Installation before control valve 3.4.10 Air venting 02 10 Figure 3-12:Air venting 1� >_5m ® Airventilation point 09/2009-4000686201-R01-SW-en www.krohne.com 13 INSTALLATION 3.4.11 Pump Figure 3-13:Installation after pump 3.5 Mounting 3.5.1 Torques and pressure Max. torque: • Step 1: approx. 50% of max. torque • Step 2: approx. 80% of max. torque • Step 3: 100% of max. torque given in tables Nominal size Pressure rating Max. allowable operating pressure EN 1092-1 ar psig DN2.5...80 PN40 16 580 DN 100 PN 16 16 230 PN25 25 360 Pressures ASME Nominal size ressure rating Max.allowable operating pressure ASME B 16.5 �k bar psig 1/10...4"' 150 lb 16 230 1/10...3" 300 lb 40 580 4" 3001b 25 360 14 www.krohne.com 09/2009-4000686201-R01-SW-en INSTALLATION Torques EN 1092-1 Nominal Pipe Max. allowable torque with gaskets made of size flanges EN 1092-1 Gylon Chemotherm FPM /FKM 1) Rating Nm ftlb Nm ftlb Nm ftlb DN2.5...10 PN40 - - - - 32 24 DN15 PN40 - - - - 36 27 DN25 PN40 22 16 32 24 - - DN40 PN40 47 35 66 49 - - DN50 PN40 58 43 82 60 - - DN80 PN40 48 35 69 51 - - DN100 PN16 75 55 106 78 - - PN25 94 69 133 98 - - 1Q according DIN ISO 1629/ASTM D 1418 Torques ASME Nominal Pipe Max. allowable torque with gaskets made of size flanges ASME Gylon Chemotherm FPM/FKM 1Q B 16.5 Rating Nm ftlb Nm ftlb Nm ftlb 1/10...3/8" 1501b - - - - 35 26 1/2" 1501b - - - - 35 26 1" 150 lb 24 18 33 24 - - 11/2" 1501b 38 28 54 40 - - 2" 1501b 58 43 83 61 - - 3" 1501b 98 72 138 102 - - 4" 1501b 75 55 108 80 - - 1Q according DIN ISO 1629/ASTM D 1418 09/2009-4000686201-R01-SW-en www.krohne.com 15 0 ELECTRICAL CONNECTIONS 4.1 Safety instructions QDANGER! All work on the electrical connections may only be carried out with the power disconnected. Take + note of the voltage data on the nameplate! QDANGER! Observe the national regulations for electrical installations! DANGER! EX For devices used in hazardous areas, additional safety notes apply,please refer to the Ex documentation. WARNING! Observe without fail the local occupational health and safety regulations.Any work done on the ' electrical components of the measuring device may only be carried out by properly trained specialists. a /NFORMA T/ON! Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. 4.2 Grounding QDANGER! �j The device must be grounded in accordance with regulations in order to protect personnel ++ against electric shocks. 10 02 7 Figure 4-1:Grounding Metal pipelines,not internally coated.Grounding without grounding rings! Metal pipelines with internal coating and non-conductive pipelines.Grounding with grounding rings! 16 www.krohne.com 09/2009-4000686201-R01-SW-en ELECTRICAL CONNECTIONS p 4.3 Virtual reference for IFC 300 (C, W and F version) Figure 4-2:Virtual reference Possible if: >_ DN10 Electrical conductivity>_ 200 NS/cm 09/2009-4000686201-R01-SW-en www.krohne.com 17 SERVICE M 1 5.1 Spare parts availability The manufacturer adheres to the basic principle that functionally adequate spare parts for each device or each important accessory part will be kept available for a period of 3 years after delivery of the last production run for the device. This regulation only applies to spare parts which are under normal operating conditions subjects to wear and tear. 5.2 Availability of services The manufacturer offers a range of services to support the customer after expiration of the warranty. These include repair, technical support and training. a /NFORMA T/ON! For more precise information,please contactyour local representative. 5.3 Returning the device to the manufacturer 5.3.1 General information This device has been carefully manufactured and tested. If installed and operated in accordance with these operating instructions, it will rarely present any problems. A CAUTION! Shouldyou nevertheless needto return a device forinspection orrepair pleasepaystrict attention to the following points: • Due to statutory regulations on environmental protection and safeguarding the health and safety of our personnel, manufacturer may only handle, test and repair returned devices that have been in contact with products without risk to personnel and environment. • This means that the manufacturer can only service this device if it is accompanied by the following certificate fsee next sectionl confirming that the device is safe to handle. If the device Aog if the device has been operated with toxic, caustic, flammable or water-endangering products, you are kindly requested: • to check and ensure, if necessary by rinsing or neutralizing, that all cavities are free from such dangerous substances, • to enclose a certificate with the device confirming that is safe to handle and stating the product used. 18 www.krohne.com 09/2009-4000686201-R01-SW-en SERVICE 5.3.2 Form (for copying) to accompany a returned device Company: Address: Department: Name: Tel. no.: Fax no.: Manufacturer's order no.or serial no.: The device has been operated with the following medium: This medium is: water-hazardous toxic caustic flammable We checked that all cavities in the device are free from such substances. We have flushed out and neutralized all cavities in the device. We hereby confirm that there is no risk to persons or the environment through any residual media contained in the device when it is returned. Date: Signature: Stamp: 5.4 Disposal A CA UT/ON! Disposal must be carried out in accordance with legislation applicable in your country. 09/2009-4000686201-R01-SW-en www.krohne.com 19 p TECHNICAL DATA 6.1 Measuring principle An electrically conductive fluid flows inside an electrically insulating pipe through a magnetic field. This magnetic field is generated by a current, flowing through a pair of field coils. Inside of the fluid, a voltage U is generated: U =v* k* B * D in which: v= mean flow velocity k= factor correcting for geometry B = magnetic field strength D = inner diameter of flow meter The signal voltage U is picked off by electrodes and is proportional to the mean flow velocity v and thus the flow rate q. The signal voltage is quite small (typically 1 mV at v=3 m/s/ 10 ft/s and field coil power of 1 W). Finally, a signal converter is used to amplify the signal voltage, filter it (separate from noise) and convert it into signals for totalising, recording and output processing. 2 1 4 1 1) Voltage(induced voltage proportional to flow velocity) 2� Electrodes 3Z Magnetic field 4� Field coils 20 www.krohne.com 09/2009-4000686201-R01-SW-en OPTIFLUX 5000 a— TECHNICAL DATA 6.2 Technical data a /NFORMA T/ON! i • The following data is provided for general applications. /fyou require data that is more relevant to your specific application,please contact us oryour local representative. • Additional information(certificates, special tools, software,...l and complete product documentation can be downloaded free of charge from the website fDownloadcenterl. Measuring system Measuring principle Faraday's law Application range Electrically conductive fluids Measured value Primary measured value Flow velocity Secondary measured value Volume flow, mass flow,electrical conductivity,coil temperature Design Features Sandwich version with optimized flow tube Modular construction The measurement system consists of a flow sensor and a signal converter. It is available as compact and as separate version. More information about the signal converter can be found in the documentation of the signal converter. Compact version With IFC 100 converter:OPTIFLUX 5100 C With IFC 300 converter: OPTIFLUX 5300 C Remote version In wall(W) mount version with IFC 100 converter: OPTIFLUX 5100 W In field (F),wall(W)or rack(R) mount version with IFC 300 converter: OPTIFLUX 5300 F,W or R Nominal diameter DN2.5...100/1/10...4" Measurement range -12...+12 m/s/-40...+40 ft/s 09/2009-4000686201-R01-SW-en www.krohne.com 21 TECHNICAL DATA Measuring accuracy Reference conditions Medium:water Temperature: 20°C/68°F Inlet section: 10 DN Outlet section: 5 DN Flow velocity: > 1 m/s/>3 ft/s Operating pressure: 1 bar/14.5 psig Valve closing time variation: < 1 ms Wet calibrated on EN 17025 accredited calibration rig by direct volume comparison Maximum measuring error Related to volume flow(MV= Measured Value) These values are related to the pulse/frequency output The additional typical measuring deviation for the current output is ±10 µA With IFC 100 converter: DN2.5...6:±0.4%ofMV+ 1 mm/s DN10...100:±0.3%of MV+ 1 mm/s With IFC 300 converter: DN2.5...6:±0.3%of MV+2 mm/s DN10...100:±0.15%ofMV+ 1 mm/s Repeatability ±0.1%of MV, minimum 1 mm/s Long term stability ±0.1%of MV Special calibration On request Operating conditions Temperature Process temperature Ceramic liner: -40...+180°C/-40...+356°F(remote versions,compact versions are limited to+140°C/+284°F). For Ex versions different temperature ranges are applicable. Please see the relevant Ex documentation for details. Maximum temperature change 120°C/248°F (shock) Ambient temperature Non-Ex: -40...+65°C/-40...+149°F Ex: -40...+60°C/-40...+140'F Storage temperature -50...+70°C/-58...+158°F 22 www.krohne.com 09/2009-4000686201-R01-SW-en TECHNICAL DATA Pressure Ambient Atmospheric Nominal flange pressure Standard: DIN (EN 1092-1) PN16 for DN100 PN40 for DN2.5...80 Option: PN25 for DN100 ASME B16.5 Standard: 150 lbs for ASME1/10...4" Option: 300 lbs RF for ASME1/10...4" Vacuum load 0 mbar/0 psi Pressure ranges for secondary Pressure resistant up to 40 bar/580 psi containment Burst pressure up to approx. 160 bar/2320 psi Chemical properties Physical condition Liquids Electrical conductivity Non water: DN25...100:>_1 µS/cm DN4...15:>_5 µS/cm DN2.5:>_ 10 µS/cm Demineralised cold water: DN2.5...100:>_20 µS/cm Permissible gas content(volume) <_5% Permissible solid content IFC 1 00:<_ 10%; IFC 300<_70% (volume) Recommended flow velocity -12...+12 m/s/-40...+40 ft/s Other conditions Protection category acc.to IEC Standard: IP66/67(NEMA 4/4X/6) 529/EN 60529 Optional: IP68(NEMA 6P) Vibration resistance IEC 68-2-6 09/2009-4000686201-R01-SW-en www.krohne.com 23 TECHNICAL DATA Installation condtitions Inlet run >_5 DN (without disturbing flow,after a single 90°bend) >10 DN (after a double bend 2x 90°) >10 ON (behind a control valve) Outlet run >2 ON Dimensions and weights For detailed information see chapter"Dimensions and weights". Materials Sensor housing DN2.5...15:Stainless steel Duplex(1.4462) DN25...100:Stainless steel AISI 304(1.4306) Measuring tube Ceramic Grounding rings Stainless steel, Hastelloy®C,Titanium,Tantalum Other materials on request Also available as alternative for grounding rings(IFC 300 only): Virtual Reference. Stud bolts and nuts Standard:Steel Option:Stainless steel, rubber centering sleeves Gaskets FPM/FKM,Gylon, EPDM, Kalrez, PTFE-PF 29, Chemotherm Other materials on request Measuring electrodes DN2.5...15: Cermet DN25...100: Platinum Process connections DIN DN2.5...100 in PN16...40 ASME 1/10...4" in 150...300 lbs JIS DN2.5...100 in JIS 10...20 K Electrical connections Signal cable Only for remote systems Type A Standard cable, double shielded. Max. length:600 m/1950 ft(dep.on electrical conductivity and measuring sensor).See documentation of the converter for more information. Type B Optional cable,triple shielded. Max. length:600 m/1950 ft(dep.on electrical conductivity and measuring sensor).See documentation of the converter for more information. 24 www.krohne.com 09/2009-4000686201-R01-SW-en 11 TECHNICAL DATA Approvals and certifications CE Sign This device fulfills the statutory requirements of the EC directives. The manufacturer certifies successful testing of the product by applying the CE mark. Hazardous areas ATEX KEMA 04 ATEX 2126 X ATEX II 2 GD EEx me is IIC ATEX II 2 GD EEx de is IIC T6...T3 For more details,see Ex documentation of sensor and converter. FM Class I, Div 2,groups A, B,C and D Class II, Div 2, groups F and G Class III, Div 2, groups F and G CSA Class I, Div 2,groups A, B,C and D Class II, Div 2, groups F and G IEC-Ex pending NEPSI GYJ05240 Ex me is IIC T6...T3 Ex de is IIC T6...T3 Other approvals and standards Electromagnetic compatibility Directive:89/336/EEC and A1,A2 NAMUR NE21/04 Harmonized standard: EN 61326-1 : 2006 Low Voltage Directive Directive: 2006/95/EC Harmonized standard: EN 61010 :2001 Pressure Equipment Directive Directive:97/23/EC Category I, II or SEP Fluid group 1 Production module H Custody transfer Standard:without Option: MI-001, MI-005 Hygiene Ceramic measuring tube is FDA approved. 09/2009-4000686201-R01-SW-en www.krohne.com 25 p TECHNICAL DATA 6.3 Dimensions and weights 2 � � 0 - - - - - - ISM - o �o D 65 Figure 6-1:Contruction details DN2.5...15 1� 0-ring 2� Grounding ring O O O O O -0 — — — O D 0.8 .0.8 Figure 6-2:Construction details DN25...100 1� Situation without grounding rings 2� Gasket a /NFORMA T/ON! • All data given in the following tables are based on standard versions of the sensor only. • Especially for smaller nominal sizes of the sensor, the converter can be bigger than the sensor. • Note that for other pressure ratings than mentioned, the dimensions may be different. • For full information on converter dimensions see relevant documentation. 26 www.krohne.com 09/2009-4000686201-R01-SW-en TECHNICAL DATA Nominal size Dimensions [mm] Approx. weight DN PN [bar] L H W Odl Od4 [kg] 5 65 10 123 44 - - 1.6 4 40 65 10 123 44 - - 1.6 6 40 65 1D 123 44 - - 1.6 10 40 65 1D 123 44 - - 1.6 15 40 65 1Q 123 44 - - 1.6 25 40 58© 116 68 26 46 1.6 40 40 83(2) 51 131 62 2.4 50 40 103© 149 101 74 2.9 80 40 153(Z 181 1331 6.4 100 16 203(2) 206 158 101 133 8.8 11) Total fitting length of flowmeter with integrated rings:Dim.L+2 x gasket thickness. (2) Total fitting length of flowmeter without rings:Dim.L only(no gaskets required). Nominal size Dimensions [inches] Approx.weight [lbs] ASME PN [psi] L H W Odl Od4 1/10" 580 2.56 10 4.84 1.73 - 3.53 1/8" 580 2.56 1O 4.84 1.73 - - 3.53 '/" 580 2.56 1D 4.84 1.73 - - 3.53 3/8" 580 2.56 O 4.84 1.73 - - 3.53 ''/2" 580 2.56 O 4.84 1.73 - - 3.53 1" 580 2.28 02 4.57 2.68 1.02 1.81 3.53 1'h" 580 3.27(Z 5.16 3.27 1.54 2.44 5.29 2" 580 4.06© 5.87 3.98 2.01 2.91 6.39 qM 580 6.022 7.13 5.24 3.15 4.17 14.11 4" 232 7.99(2) 8.11 6.22 3.98 5.24 19.40 11) Total fitting length of flowmeter with integrated rings:Dim.L+2 x gasket thickness. (2) Total fitting length of flowmeter without rings:Dim.L only(no gaskets required). QV CAUTION! Pressures are applicable at 20°C/68°F. • For higher temperatures, the pressure and temperature ratings are as perASMEB 16.5/up to 24'JorASMEB16.471>24 V. • Dimensions for other sizes on request. 09/2009-4000686201-R01-SW-en www.krohne.com 27 r� r . rti,y • •• M• • • •• AW to ri KROHNE product overview • Electromagnetic flowmeters • Variable area flowmeters • Ultrasonic flowmeters • Mass flowmeters • Vortex flowmeters • Flow controllers Q • Level meters 0 • Temperature meters L 3 • Pressure meters v • Analysis products L U s • Measuring systems for the oil and gas industry • Measuring systems for sea-going tankers v 0 Head Office KROHNE Messtechnik GmbH & Co. KG Ludwig-Krohne-Str. 5 D-47058 Duisburg (Germany) g Tel.:+49 (0)203 301 0 0 0 Fax:+49 (0)203 301 10389 Z infofdkrohne.de & The current list of all KROHNE contacts and addresses can be found at: KROHNE Y o www.krohne.com