Loading...
HomeMy WebLinkAboutQS_OPTIFLUX 2000__en__120328_7309842500_R05 1 M OPTI FLUX 2000 Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. ©KROHNE 02/2012-7309842500-QS OPTIFLUX2000 R05 en K R O H N E CONTENTS OPTIFLUX2000 1 Safety instructions 3 2 Installation 4 2.1 Scope of delivery...............................................................................................................4 2.2 Device description ............................................................................................................5 2.3 Nameplate........................................................................................................................5 2.4 Storage .............................................................................................................................6 2.5 Transport..........................................................................................................................6 2.6 Pre-installation requirements.........................................................................................6 2.7 Installation conditions......................................................................................................7 2.7.1 General requirements ............................................................................................................7 2.7.2 Inlet and outlet........................................................................................................................7 2.7.3 Mounting position....................................................................................................................7 2.7.4 Flange deviation......................................................................................................................7 2.7.5 T-section .................................................................................................................................8 2.7.6 Vibration ..................................................................................................................................8 2.7.7 Magnetic field..........................................................................................................................9 2.7.8 Bends ......................................................................................................................................9 2.7.9 Open discharge..................................................................................................................... 10 2.7.10 Control valve ....................................................................................................................... 10 2.7.11 Air venting ........................................................................................................................... 10 2.7.12 Pump................................................................................................................................... 11 2.7.13 Temperatures ..................................................................................................................... 11 2.8 Mounting......................................................................................................................... 12 2.8.1 Torques and pressures......................................................................................................... 12 3 Electrical connections 15 3.1 Safety instructions.......................................................................................................... 15 3.2 Grounding ....................................................................................................................... 15 3.3 Virtual reference for IFC 300 (C, W and F version)........................................................ 17 3.4 Connection diagrams ..................................................................................................... 17 4 Technical data 18 4.1 Dimensions and weights ................................................................................................ 18 5 Notes 21 2 www.krohne.com 02/2012-7309842500-Q6 OPTIFLUX2000 R05 en SAFETY INSTRUCTIONS Warnings and symbols used QDANinfor This information refers to the immediate danger when working with electricity. DANCER! These warnings must be observed without fail. Even partial disregard of this warning can lead to serious health problems and even death. There is also the risk of seriously damaging the device or parts of the operator's plant. WARNING. A! Disregarding this safety warning, even if only in part,poses the risk of serious health problems. There is also the risk of damaging the device or parts of the operator's plant. CAUTlU1/! Q ° Disregarding these instructions can result in damage to the device or to parts of the operator's plant. a /NFQ4MA T/U'V.i These instructions contain important information for the handling of the device. HANDLING • This symbol designates all instructions for actions to be carried out by the operator in the specified sequence. i RESULT This symbol refers to all important consequences of the previous actions. Safety instructions for the operator CAUTION! Installation, assembly, start-up and maintenance may only be performed by appropriately Q trained personnel. The regional occupational health and safety directives must always be observed. ® LEG4L NOTICE! The responsibility as to the suitability and intended use of this device rests solely with the user. The supplier assumes no responsibilityin the event of improper use by the customer. Improper installation and operation maylead to loss of warranty. In addition, the "Terms and Conditions of Sale"apply which form the basis of the purchase contract. a /NFQ4MA TlU'V.i • Further information can be found on the supplied CD-ROW in the manual, on the data sheet, in special manuals, certificates and on the manufacturer's webs/te. • lfyou need to return the device to the manufacturer or supplier,please fill out the form contained on the CD-ROM and send it with the device. Unfortunately, the manufacturer cannot repair or inspect the device without the completed form. 02/2012-7309842500-QS OPTI FL UX 2000 R05 en www.krohne.com 3 INSTALLATION •- ��� 2.1 Scope of delivery a /NFQ4MAT/Q'V.i iDo a check of the packing list to make sure that you have all the elements given in the order. a /NFQ4MAT/C,Y1/.i 1 Inspect the cartons carefully for damages or signs of rough handling. Report damage to the carrier and to the local office of the manufacturer. a /NFQ4MAT/Q'V.i 1 The remote version will arrive In two cartons. 07e carton contains the converter and one carton contains the sensor. O ��02nn OO �I E" PAZ— © O Figure 2-1:Scope of delivery 1 Ordered flowmeter 2 Product documentation 3 Factory calibration report 4 CD-ROM with product documentation in available languages 5 Grounding rings(optional) 6 Signal cable(remote versions only) a /NFQ4MAT/Q'V.i iAssembly materials and tools are not part of the delivery. Use the assembly materials and tools in compliance with the applicable occupational health and safety dlrectives. 4 www.krohne.com 02/2012-7309842500-QS OPTIFLUX2000 R05 en ■ I N STAL LATI ON 2 2.2 Device description Electromagnetic fIowmeters are designed exclusively to measure the flow and conductivity of electrically conductive, liquid media. Your measuring device is supplied readyfor operation.The factory settings for the operating data have been made in accordance with your order specifications. The following versions are available: • Compact version (the signal converter is mounted directly on the measuring sensor) • Remote version (measuring sensor with connection box and a signal converter in a remote (field)housing) 00 00 0 0 0 0 1 Remote version 2 Compact version with IFC 300 signal converter 3 Compact version with IFC 100(0°)signal converter 4 Compact version with IFC 100(45°)signal converter 2.3 Nameplate a /NFQ4MAT/GY1/.i 1 Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. t0 KR O H N E NIL 3313 LC Dordrecht OPTIFLUX 2000 OS/N:Axx xxxxx Manufactured:20XX C 0038 GK=2.714 GKL=5.123 DN:150mm/6 inch PED(97/23/EC): O PS1=40 bar@TSir_40°C PS2=32 bar @ TS2=180°C IP66/67 PT=60 bar @ TT -20°C 1 Name and address of the manufacturer 2 Type designation of the flowmeter and CE sign with number(s)of notified body/bodies 3 Calibration data 4 PIED data 02/2012-7309842500-OS OPTIFLUX2000 R05 en www.krohne.com 5 INSTALLATION am OPTIFLUX2000 2.4 Storage • Store the device in a dry and dust-free location. • Avoid lasting direct exposure to the sun. • Store the device in its original packaging. • Storage temperature: -50 ...+70°C/ -58...+158°F 2.5 Transport Signal converter • No special requirements. Compact version • Do not lift the device by the signal converter housing. • Do not use lifting chains. • To transport flange devices, use lifting straps.Wrap these around both process connections. O O Figure 2-2:Transport 2.6 Pre-installation requirements Make sure that you have all necessary tools available: • Allen key(4 mm) • Small screwdriver • Wrench for cable glands • Wrench for wall mounting bracket (remote version only) • Torque wrench for installing flowmeter in pipeline 6 www.krohne.com 02/2012-7309842500-QS OPTIFLUX2000 R05 en •- ��� INSTALLATION 2 2.7 Installation conditions 2.7.1 General requirements a /NFQ4MAT/GY1/.i 1 The following precautions must be taken to ensure reliable installation. • Make sure that there is adequate space to the sides. • Protect the signal converter from direct sunlight and instal/a sun shade if necessary. • Signal converters insta/led in control cabinets require adequate cooling, e.g. by fan or heat exchanger. • Do not expose the signal converter to intense vibration. The flowmeters are tested for a vibration level in accordance with/EC68-2-64. 2.7.2 Inlet and outlet O 20 Figure 2-3:Recommended inlet and outlet 1 >_5DN 2 >_2DN 2.7.3 Mounting position vx� Figure 2-4:Mounting position 2.7.4 Flange deviation A CAUT/CYV! Max.permissible deviation of pipe flange faces: Lmax- Lmin-<0.5 mm/0.02" 02/2012-7309842500-OS OPTIFLUX2000 R05 en www.krohne.com 7 INSTALLATION •- 000 0 -- ---------------- - - ---------------- 0 Figure 2-5:Flange deviation 1 Lmax 2 Lmin 2.7.5 T-section Figure 2-6:Distance behind a T-section 1 >_10DN 2.7.6 Vibration Figure 2-7:Avoid vibrations 8 www.krohne.com 02/2012-7309842500-OS OPTI FLUX 2000 R05 en OPTIFLUX2000 INSTALLATION 2.7.7 Magneticfield r Figure 2-8:Avoid magnetic fields 2.7.8 Bends Figure 2-9: Installation in bending pipes Figure 2-10:Installation in bending pipes 0212012-7309842500-OS OPTI FLUX 2000 R05 en www.krohne.com 9 INSTALLATION OPTIFLUX2000 2.7.9 Open discharge Figure 2-11:Installation in front of an open discharge 2.7.10 Control valve Figure 2-12:Installation in front of a control valve 2.7.11 Air venting 02 t0 Figure 2-13:Air venting 1 >_5m 2 Air ventilation point 10 www.krohne.com 02/2012-7309842500-OS OPTI FLUX 2000 R05 en OPTIFLUX2000 INSTALLATION 2.7.12 Pump Figure 2-14:Installation behind a pump 2.7.13 Temperatures A CAUTIOV! Protect the device from direct sunlight. Temperature range Process[°C] Ambient [°C] Process[°F] Ambient [°F] min. max. min. max. min. m ax. m i n. Fm ax, Hard rubber/Polyolefin 1 Separate fIow sensor -5 80 -40 65 23 176 -40 149 Compact with IFC300 -5 80 -40 65 23 176 -40 149 Compact with IFC 100 -5 80 -40 65 23 176 -40 149 Polypropylene 2 Separate fIow sensor -5 90 -40 65 23 194 -40 149 Compact with IFC 300 -5 90 -40 65 23 194 -40 149 Compact with IFC 100 -5 90 -40 65 23 194 -40 149 1 Polyolefin is only available for DN200...1000 2 Polypropylene is only available for DN25...150 0212012-7309842500-OS OPTI FLUX 2000 R05 en www.krohne.com 11 INSTALLATION OPTIFLUX2000 2.8 Mounting 2.8.1 Torques and pressures The maximum pressure and torques values for the fIowmeter are theoretical and calculated for optimum conditions and use with carbon steel flanges. Figure 2-15:Tightening of bolts Tightening of bolts • Always tighten the bolts uniformely and in diagonally opposite sequence. • Do not exceed the maximum torque value. • Step 1: Apply approx. 50%of max.torque given in table. • Step 2: Apply approx. 80%of max.torque given in table. • Step 3: Apply 100%of max.torque given in table. 12 www.krohne.com 02/2012-7309842500-QS OPTIFLUX2000 R05 en OPTIFLUX2000 INSTALLATION 2 Nominal size Pressure Bolts Max. torque [Nm] 1 DN [mm] rating Polyolefin Polypropylene Hard rubber 25 PN 40 4xM12 - 22 11 32 PN 40 4xM16 - 37 19 40 PN 40 4 x M 16 - 43 25 50 PN 40 4xM16 - 55 31 65 PN 16 4 x M 16 - 51 42 65 PN 40 8xM16 - 38 21 80 PN 40 8 x M 16 - 47 25 100 PN 16 8 x M 16 - 39 30 125 PN 16 8 x M 16 - 53 40 150 PN 16 8 x M 20 - 68 47 200 PN 10 8 x M 20 68 - 68 200 PN 16 12 x M 20 45 - 45 250 PN 10 12 x M 20 65 - 65 250 PN 16 12 x M 24 78 - 78 300 PN 10 12 x M 20 76 - 76 300 PN 16 12 x M 24 105 - 105 350 PN 10 16 x M 20 75 - 75 400 PN 10 16 x M 24 104 - 104 450 PN 10 20 x M 24 93 - 93 500 PN 10 20 x M 24 107 - 107 600 PN 10 20 x M 27 138 - 138 700 PN 10 24 x M 27 163 - 163 800 PN 10 24 x M 30 219 - 219 900 PN 10 28 x M 30 205 - 205 1000 PN 10 28 x M 33 261 - 261 1 The specified torque values are dependent on variables(temperature, bolt material,gasket material, lubricants,etc.)which are not within the control of the manufacturer.Therefore these values should be regarded as indicative only. INFCa4MA TlU'V.i 1 Other sizes/pressure ratings on request. 0212012-7309842500-OS OPTI FLUX 2000 R05 en www.krohne.com 13 INSTALLATION OPTIFLUX2000 Nominal size Flange class Bolts Max.torque [Ibf.ft] 1 [inches] [lb] Polyolefin Polypropylene Hard rubber 1 150 4 X 1/2" - qF 6.7 3.2 1 1/2 150 4 X 1/2" - 13 9 2 150 4 X 5/8" - 24 17 3 150 4 X 5/8" - 43 29 4 150 8 X 5/8" - 34 23 6 150 8 X 3/4" - 61 38 8 150 8 X 3/4" 51 - 51 10 150 12 X 7/8" 58 - 58 12 150 12 X 7/8" 77 - 77 14 150 12 x 1" 69 - 69 16 150 16 X 1" 67 - 67 18 150 16 X 1 1/8" 105 - 105 20 150 20 X 1 1/8" 94 - 94 24 150 20 x 1 1/4" 133 - 133 1 The specified torque values are dependent on variables(temperature,bolt material,gasket material, lubricants,etc.)which are not within the control of the manufacturer.Therefore these values should be regarded as indicative only. a /NFQ4MAT/QV! 1 Other sizes/pressure ratings on request. 14 www.krohne.com 02/2012-7309842500-QS OPTI FLUX 2000 R05 en •- EL ECTRI CAL CON N ECTI ON S 3 3.1 Safety instructions QDANCER! All11workwork on the electrical connections mayors/ybe carried out with the power disconnected. Take note of the voltage data on the nameplate! Observe the national regulations for electrical installations! DANCER! EX For devices used In hazardous areas, additional safetynotes apply,please refer to the Ex documentation. WARNING! Observe without fail the local occupational health and safety regulations.Any work done on the ' electrical components of the measuring device mayors/ybe carried out byproperly trained specialists. a /NF04MA POW iLook at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. 3.2 Grounding QDANGER! The device must be grounded in accordance with regulations in order to protect personnel against electric shocks. ) 20 �7; Figure 3-1:Grounding 1 Metal pipelines,not internally coated.Grounding without grounding rings. 2 Metal pipelines with internal coating and non-conductive pipelines.Grounding with grounding rings. 02/2012-7309842500-QS OPTI FL UX 2000 R05 en www.krohne.com 15 3 EL ECTRI CAL CON N ECTI ON S •- 0 0 0 T o 0 Figure 3-2:Different types of grounding rings 1 Grounding ring number 1 2 Grounding ring number 2 3 (rounding ring number 3 Grounding ring number 1: • 3 mm / 0.1" thick (tantalum: 0.5 mm / 0.02") Grounding ring number 2: • 3 mm / 0.1" thick • Prevents damage to the flanges during transport and installation • Especially for flow sensors with PTFE liner Grounding ring number 3: • 3 mm / 0.1" thick • With cylindrical neck (length 30 mm/ 1.25" for DN10...150/ 3/8...6") • Prevents damage to the liner when abrasive liquids are used 16 www.krohne.com 02/2012-7309842500-QS OPTIFLUX2000 R05 en •- ■ EL ECTRI CAL CON N ECTI ON S 3 3.3 Virtual reference for IFC 300 (C, Wand F version) The virtual reference option on the IFC 300 flow converter provides complete isolation of the measurement circuit. Benefits of virtual reference: • Grounding rings or grounding electrodes can be omitted. • Safety increases by reducing the number of potential leakage points. • The installation of the flowmeters is much easier. L L Figure 3-3:virtual reference Minimum requirements: • Size: >_DN10 • Electrical conductivity: >_200 pS/cm • Electrode cable: max. 50 m / 164 ft,type IDS 3.4 Connection diagrams a /NFQ4MAT/Q'V.i iFor the connection diagrams please refer to the documentation of the applicable converter. 02/2012-7309842500-OS OPTIFLUX2000 R05 en www.krohne.com 17 TECHNICAL DATA OPTIFLUX2000 4.1 Dimensions and weights Remote version a=77 mm/3.1" b c b=139mm/5.5" 1 a tw c=106mm/4.2" Total height=H+a L Compact version with b c a=155 mm/6,1" 1 FC 300 b=230mm/9.1" 1 O c=260 m m/ 10.2" a � Total height=H+a o � o H - -0- 0 0 L W Compact version with a=82 mm/3.2" IFC100(0°) c b b=161 mm/6.3" a c=257mm/ 10.1" 1 O olo O Total height=H+a o o H 0 c L W Compact version with b c a=186 mm/7.3" 1 FC 100(45°) b=161 mm/6.3" a c=184mm/2.7" 1 Total height=H+a - - o�o if L W 1 The value may vary depending on the used cable glands. 18 www.krohne.com 02/2012-7309842500-OS OPTI FLUX 2000 R05 en OPTIFLUX2000 TECH N I CAL DATA 4 /NFQ4MAT/GY1/.i 1 • All data given in the following tables are based on standard versions of the sensor only. • Especially for smaller nominal sizes of the sensor, the converter can be bigger than the sensor. • Note that for other pressure ratings than mentioned, the dimensions maybe different. • For full information on converter dimensions see relevant documentation. EN 1092-1 Nominal Dimensions[mm] Approx. size DN weight [mm] Standard ISO Insertion H W [kg] length length 25 150 200 140 115 5 32 150 200 157 140 6 40 150 200 166 150 7 50 200 200 186 165 11 65 200 200 200 185 9 80 200 200 209 200 14 100 250 250 237 220 15 125 250 250 266 250 19 150 300 300 300 285 27 200 350 350 361 340 34 250 400 450 408 395 48 300 500 500 458 445 58 350 500 550 510 505 78 400 600 600 568 565 101 450 600 - 618 615 111 500 600 - 671 670 130 600 600 - 781 780 165 700 700 - 898 895 248 800 800 - 1012 1015 331 900 900 - 1114 1115 430 1000 1000 - 1225 1230 507 1200 1200 - 1417 1405 555 1400 1400 - 1619 1630 765 1600 1600 - 1819 1830 1035 1800 1800 - 2027 2045 1470 2000 2000 - 2259 2265 1860 02/2012-7309842500-QS OPTIFLUX2000 R05 en www.krohne.com 19 TECHNICAL DATA OPTIFLUX2000 ASMEB16.5/ 1501bfIanges Nominal size Dimensions[inches] Approx.weight [inches] [lb] L H W 5.91 5.39 4.25 7 1'/" 5.91 6.10 5.00 11 7.87 7.05 5.98 18 3" 7.87 8.03 7.50 26 4" 9.84 9.49 9.00 44 5" 9.84 10.55 10.00 49 6" 11.81 11.69 11.00 64 8" 13.78 14.25 13.50 95 10" 15.75 16.30 16.00 143 12" 19.69 18.78 19.00 207 14" 27.56 20.67 21.00 284 16" 31.50 22.95 23.50 364 18" 31.50 24.72 25.00 410 20" 31.50 26.97 27.50 492 24" 31.50 31.38 32.00 675 ASME B16.5/ 300 lb flanges Nominal size Dimensions [inches] Approx.weight [inches] L [lb] H W 1" 5.91 5.71 4.87 11 1'/' 7.87 6.65 6.13 13 2" 9.84 7.32 6.50 22 3" 9.84 8.43 8.25 31 4" 11.81 10.00 10.00 44 6" 12.60 12.44 12.50 73 8" 15.75 15.04 15.00 157 10" 19.69 17.05 17.50 247 12" 23.62 20.00 20.50 375 14" 27.56 21.65 23.00 474 16" 31.50 23.98 25.50 639 20" 31.50 28.46 30.50 937 24" 31.50 33.39 36.00 1345 20 www.krohne.com 02/2012-7309842500-OS OPTI FLUX 2000 R05 en OPTIFLUX2000 NOTES 0212012-7309842500-OS OPTI FLUX 2000 R05 en www.krohne.com 21 NOTES OPTIFLUX2000 22 www.krohne.com 02/2012-7309842500-QS OPTI FLUX 2000 R05 en OPTIFLUX2000 NOTES 0212012-7309842500-OS OPTI FLUX 2000 R05 en www.krohne.com 23 rti,y • y • j •• ~ • T 1 - r `t KROHNE product overview • Electromagnetic flowmeters • Variable area flowmeters • Ultrasonic flowmeters 0 • Mass flowmeters • Vortex flowmeters 0 -n • Flow controllers 0 • Level meters L • Temperature meters U • Pressure meters • Analysis products 2 • Products and systems for the oil & gas industry 0 cD • Measuring systems for the marine industry x J LL H N Head Office KROHNE Messtechnik GmbH N co Ludwig-Krohne-Str. 5 o 47058 Duisburg (Germany) N Tel.:+49(0)203 301 0 0 N Fax:+49(0)203 301 10389 0 z info@crohne.de WThe current list of all KROHNE contacts and addresses can be found at: KR 0 H N E o www.krohne.com