HomeMy WebLinkAboutQS_OPTIFLUX 2070__en__080411_7309992100_R00 s i 47 KROHNE OPTIFLUX 2070 Battery powered electromagnetic flowmeter KROHNE OPTIFLUX 2070 General safety notes You can find the newest and/or additional information on the CD-ROM provided, in the handbook,the datasheet,special manuals, certificates and the download center at www.krohne.com. 0 Installation, mounting,commissioning,and maintenance can be performed only by trained personnel. Responsibility for suitability and intended use of this instrument rests © solely with the user. The supplier accepts no liability for inappropriate use by the customer. Improper installation and operation may lead to loss of warranty. Moreover,the"general terms and conditions" on the back of the bill apply,which form the basis for the sales contract. If you have to send the device back to the manufacturer or supplier,fill out the form contained on the CD-ROM and enclose it with the device. Unless this form is completely filled out, it will unfortunately not be possible for the manufacturer to perform repair or inspection. Respect general and local electrical safety requirements. 2 7309992100 OPTIFLUX 2070 Visual check KROHNE NL.333'LC�aG CE OPTIFLUX 20]0C BeMeryp M36V SM A06123a6 ManuM—d 2006 GKO70 102U 0 Q�wrvvi kroM1ne cam Wetletl materiels PP 316 Scope of delivery 0 © © O Alf= 0 i o 0 OPTIFLUX 2070 with blue protection cap © Quick Start © Factory calibration report 0 CD-ROM including Handbook,Quick Start,Technical datasheet © Grounding ring(optional) 0 Cable(remote version only) www.krohne.com 3 OPTIFLUX 2070 Transport o � • • J • Inlet and outlet � o 0 0 >_5DN © >_2DN 4 7309992100 OPTIFLUX 2070 Mounting position and flange deviation • O • - 0 0 0 • 0 Amax © Amin QCAUT/ON! Max.permissible deviation of pipe flange faces: Amax-Amin<0.5 mm www.krohne.com 5 OPTIFLUX 2070 Vibration Magnetic field 0 6 7309992100 OPTIFLUX 2070 Bends Open discharge IW www.krohne.com 7 OPTIFLUX 2070 T-section _ � o O O >_10DN Control valve � o 8 7309992100 OPTIFLUX 2070 Pump � � o Grounding O 0 Metal pipelines,not internally coated.Grounding without grounding rings! © Metal pipelines with internal coating and non-conductive pipelines.Grounding with grounding rings! © Grounding rings QCAUTION! The grounding of the flowmeter provides a stable and accurate measurement. www.krohne.com 9 OPTIFLUX 2070 Torques and pressures Nominal size Pressure Bolts Max.torque[Nm] DN[mm] rating Polypropylene Hardrubber 5 5,01 PN 40 4 x M 16 55 31 651 PN 16 4 x M 16 51 42 65 8 x M 16 38 21 80 PN 40 8 x M 16 47 25 100 8 x M 161 39 30 125 PN 16 8 x M 16 53 40 150 PN 16 8 x M 20 68 47 200 PN 10 8 x M 20 - 68 200 PN 16 12 x M 20 - 45 250 PN 10 12 x M 20 - 65 250 PN 16 12 x M 24 - 78 300 PN 10 12 x M 20 - 76 300 PN 16 12 x M 24 - 105 350 PN 10 16 x M 20 - 75 400 PN 10 16 x M 24 - 104 450 PN 10 20 x M 24 - 93 500 in - 600 PN 10 20 x M 27 - 138 Nominal size Flange class Bolts Max.torque[Nm] [inch] [lbs] Polypropylene Hardrubber 150 4 x 5/8" 24Ajjff 23 3 150 4 x 5/8" 43 39 4 150 8 x 5/F W 34 31 5 150 8 x 3/4" 48 43 6 150 8 x 3/4" 61 51 10 7309992100 OPTIFLUX 2070 Nominal size Flange class Bolts Max.torque[Nm] [inch] [lbs] Polypropylene Hardrubber 8 150 8 x 3/4" - 69 10 150 12 x 7/8" 12 150 12 x 7/8" - 104 14 150 12 x 1" 93 16 150 16x1" - 91 18 150 16 x 1 1/8" 143 20 150 20 x 1 1/8" - 127 24 150 2 1/4" - 180 Max. torque: • Step 1: approx. 50% of max. torque • Step 2: approx. 80% of max. torque • Step 3: 100% of max. torque given in tables above www.krohne.com 11 OPTIFLUX 2070 Terminal assignment of IFC 070 +................................ m3/h +� �.o- 12 7309992100 OPTIFLUX 2070 ' o O 0 0 I 0 \\ o 0 0 0 0 0 0 Status output 1 © Status output 2 © Not connected 0 Ground Q Pulse output A 0 Pulse output B Electrical values Pulse output passive: f<_500 Hz; I<_ 10 mA; U: 5...24 VDC (P<_ 100 mW) Status output passive: I_< 10 MA; U: 5...24 VDC (P<_ 100 mW) www.krohne.com 13 OPTIFLUX 2070 Signal and field current cable for remote version CAUTION! Always use the supplied KROHNEsignal cable. Cable connection for field version: flow sensor side 0 O © 7 8 9 1 2 3 4 0 X1 X2 0 cable length:13 cm/5" 0 cable length:5 cm/2" © cable length:8 cm/3" 0 brown+white cable,used for field current © purple +blue cable,used for electrode signals shield(terminal 1of connector X2+U-clamp) 3 • Prepare appropriate cable lengths (0...©J. • Connect the shield to the U-clamp, the brown cable to terminal 7 and the white to terminal 8. 14 7309992100 OPTIFLUX 2070 • Connect the shield to terminal 1, the purple cable to terminal 2 and the blue to terminal 3. Cable connection for field version: converter side 0 O © 78 g 1A233e4e 0 1 X2 0 0 cable length: 16 cm/6.3" © cable length:5 cm/2" © cable length: 10 cm/4" 0 brown+white cable, used for field current © purple+blue cable,used for electrode signals 0 shield (terminal 1 of connector X2+U-clamp) • Prepare appropriate cable lengths (0...©). • Connect the shield to the U-clamp, the brown cable to terminal 7 and the white to terminal 8. www.krohne.com 15 OPTIFLUX 2070 • Connect the shield to terminal 1, the purple cable to terminal 2 and the blue to terminal 3. 16 7309992100 OPTIFLUX 2070 Connection of battery ACAUTION! Please connect the battery before first use. KROHNE delivers each lFC 070 converter with a disconnected battery. / 0 :-i m3/h 1 O CM +► 90 • remove the blue protection cap of the converter • remove the 4 Allen bolts (4 mm) • remove the cover • fasten the battery connector to the internal connector in the IFC 070 converter • check that the display lights up • replace the cover www.krohne.com 17 OPTIFLUX 2070 WARNING! Make sure that the battery cable is not jammed by the cover. • tighten the 4 Allen bolts • replace the blue protection cap Display and operating elements 5 I m3 0 0 © o © o 0 battery status © optical key 0 to navigate through the menu and to scroll through the measuring pages © reset button(only accessible with removed cover) flow direction © measured value and measuring unit optical key D to navigate through the menu 18 7309992100 OPTIFLUX 2070 Programming a NOTE. KROHNEprograms the signal converter according your wishes. /t is ready to operate! The handbook on the CD contains more details. • Display test: press D button 2x 1s • Software version: press D button I 1s www.krohne.com 19 OPTIFLUX 2070 Contact KROHNE Altometer Kerkeplaat 12 3313 LC Dordrecht Postbus 110 3300 AC Dordrecht, the Netherlands www.krohne.com 20 7309992100