Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
QS_OPTIFLUX 4040_C_en__070423_7309792100_R00
ML 2.497 o, ; KROHNE OPTIFLUX 4040 C Two-wire electromagnetic flowmeter KROHNE M OPTIFLUX 4040 C General safety notes You can find additional information on the CD-ROM provided, in ° the manual, the data sheet, special manuals and certificates. L Installation, mounting, commissioning, and maintenance can be S+ performed only by trained personnel. Responsibility for suitability and intended use of this instrument • rests solely with the user. The supplier accepts no liability for inappropriate use by the cus- tomer. Improper installation and operation may lead to loss of warranty. Moreover, the "general terms and conditions" on the back of the bill apply,which form the basis for the sales contract. If you have to send the device back to the manufacturer or sup-plier, fill out the form contained on the CD-ROM and enclose it with the device. Unless this form is completely filled out, it will unfortunately not be possible for KROHNE to perform repair or inspection. Respect general and local electrical safety requirements 2 7.30979.21.00 OPTIFLUX 4040 C M Visual check KROHNE mmm_ce KROHNE Altometer, Dordrecht NL-3313 LC OPTIFL SIN:A0 6 453 C S/N:A06 61453 Manufactured:2007 Q Lj —krohne.com GKL 6.9895 f field=f line/8 K50=1.0389 K25=1.0767 DN 100 mm/4 inch 16-32 VDC -10%...+10% Wetted materieals:PFA Ta I P66/67 PED(97/23/EC) PS1=19.6 bar @ TS1<=20oC PS2=14.6 bar @ TS2=180°C PT = 29 bar @ TT= 20°C This Quick Start is applicable to software versions: • Display/control unit: 3.19019.xx.00 • ADC module: 3.19749.xx.00 • 1/0 module: 3.18748.xx.00 www.krohne.com 3 M OPTIFLUX 4040 C Scope of delivery O o 0 Flowmeter in the ordered size © Quick Start © Factory calibration report CD-ROM including Handbook,Quickstart,Data Sheet © Grounding rings(optional) Transport F] II o 1 4 7.30979.21.00 0PTIFLUX 4040 C Inlet and outlet O 0 >_5DN © >_2DN Vibration 00 www.krohne.com 5 M OPTIFLUX 4040 C Flange deviation 01 o 0 Amax © Amin Caution! Q Max. permissible deviation of pipe flange faces: • Amax - Amin< 0.5 mm 6 7.30979.21.00 OPTI FLUX 4040 C Magnetic field o www.krohne.com 7 M OPTIFLUX 4040 C Bends 8 7.30979.21.00 0PTIFLUX 4040 C Open discharge � iloli T-section . C . II� i� � I o O 0 >_10DN www.krohne.com 9 M OPTIFLUX 4040 C Air venting O 0 >_5m © air ventilation point Control valve 10 7.30979.21.00 0PTIFLUX 4040 C Pump Temperature O I I 0 Process temperature,-25...140T/-13...284T © Ambient temperature,-25...60T/-13...140T CAUTION! Q See the Handbook on the CD-ROM for the exact maximum val- ues. www.krohne.com 11 M OPTIFLUX 4040 C Grounding • u 0 Metal pipelines,not internally coated.Grounding without grounding rings © Metal pipelines with internal coating,and non-conductive pipelines.Grounding with grounding rings © Grounding rings 12 7.30979.21.00 0PTIFLUX 4040 C Torques and pressures Pressure in bar and torque in Nm(EN 1092-1 and ASME B 16.5) Size of Pipe flanges Max.allowable operating Max.allowable torque measuring tube pressure Meter size Rating/Class [bar] [Nm] DN 10 DN 15 PN 40 <40 7,6 DN 15 DN 15 PN 40 <40 9,3 DN 20 DN 20 PN 40 <_40 16 DN 25 DN 25 PN 40 <40 22 DN 50 DN 50 PN 40 <40 55 DN 65 DN 65 PN 16 <16 51 DN 80 DN 80 PN 40 <40 47 DN 100 DN 100 PN 16 <_16 39 DN 125 DN 125 PN 16 <16 53 DN 150 DN 150 PN 16 <16 68 3/8" 1/2" 150 lb <19 3,5 1/2" 1/2" 150 lb <19 3,5 3/4" 3/4" 150 lb <_19 4,8 1" 1" 150 lb <19 6,7 2" 2" 150 lb <19 24 3" 3" 150 lb <16 43 4" 4" 150 lb <_16 34 6" 6" 150 lb <_16 61 www.krohne.com 13 M OPTIFLUX 4040 C Max. torque: • Step 1: approx. 50% of max. torque • Step 2: approx. 80% of max. torque • Step 3: 100% of max. torque given in table before I it I Limits/vacuum load PFA liner: No limits for vacuum load. PTFE liner: see manual on CD-Rom. 14 7.30979.21.00 0PTIFLUX 4040 C Menu Menu concept Measuring mode Data 1.0 Operation —> 1.1 Full scale 1.2 Time constant 1.3 L.F.Cutoff 1.4 Display 1.5 Current output 1.6 Pulse output 1.7 Status output 2.0 Test 2.1 Test Q 2.2 Hardware info 3.0 Installation 3.1 Language 3.2 Flow meter 3.3 Zero set 3.4 Application 3.5 Hardware 3.6 Hart 4.0 Reset 4.1 Error reset 4.2 Counter reset ? T � www.krohne.com 15 M OPTIFLUX 4040 C Contact KROHNE Altometer Kerkeplaat 12 3313 LC Dordrecht Postbus 110 3300 AC Dordrecht, the Netherlands www.krohne.com 16 7.30979.21.00