TD_OPTIFLUX 4040_C_en__060424_7025032200_R00
—iiC oao 2.497 KROHNE _ OPTI FLUX 4040 C TechnicaL Datasheet Electromagnetic Flowmeter • 2-wire connection without additional cabling • As dynamic, reliable and accurate as a 4-wire EMF • Unimpeded pipe cross-section • No additional pressure loss • Minimum conductivity 5 pS/cm • Intrinsically safe connection CE �X KROHNE OPTIFLUX 4040 C 2-wire solution OPTIFLUX 4040 C is an electromagnetic flowmeter in 2-wire technology with the dynamics, reliability and accuracy of a 4-wire EMF. OPTIFLUX 4040 C is suitable for steady or pulsating flows. Highlights • 2-wire EMF with 4-wire functionality • Reliable readings even in case of pulsating or fast changing flows due to rapid signal processing - - • • Low power consumption and operating costs x 2.497 • Protection classes "I", "e" or"d" selectable by the user during installation • The only 2-wire electromagnetic flowmeter suitable for conductivities down to 5 pS/cm `i Industries • Chemicals -0OMNE • Iron, Steel & Metals • Minerals & Mining • Pharmaceuticals • Power Plants • Pulp & Paper • Water • Wastewater 0 All Ex approvals © Most dimensionally stable PFA liner with stainless steel mesh Aplications © Housing and flanges also available in stainless steel • Pulsating flows • For aggressive chemicals • For products with high solid contens • Suitable for control loop applications 2 www.krohne.com OPTIFLUX 4040 C Electromagnetic product range OPTIFLUX converters:All converters fit to all sensors O O IFC 300 High-performance solution © IFC 010 Economical solution OPTIFLUX sensors •+ A •• O © © O ti - 0 OPTIFLUX 1000 Economical solution © OPTIFLUX 2000 Solution for the water and wastewater industry © OPTIFLUX 4000 Standard solution for the process industry O OPTIFLUX 5000 Solution with high-tech ceramics © OPTIFLUX 6000 Sanitary and hygienic solution Special-purpose flowmeters F O WATERFLUX 2070 Battery powered watermeter solution © OPTIFLUX 4040 C 2-wire solution © TIDALFLUX 4110 PF Solution for partially filled pipelines O BATCHFLUX 5015 C Solution for volumetric filling © OPTIFLUX 7300 C Electrode-free solution www.krohne.com 3 OPTIFLUX 4040 TechnicaL Data Nominal diameter OD C4 Versions ---------- with Local display Nominal pressure Flanges Steel Al ---------- ----- --- ---------- ---------- ---------- i (1.0038) Stainless steel 304 i. Stainless steel 316 Ti(1.45711 ---------- Liner —PT FE PFA Electrodes Platinum Titanium Tantalum Low noise HC4 Low noise SS 316 Ti(1.45711 contruction fixed mounted Grounding rings Stainless steel 316 Ti(1.45711** Tantalum(ring Nol and No2 only) DN 2,5 6:ring No 1 available;DN 10 150:Ring Nol,2 and 3 available -- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ��� ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- OPTIFLUX 4040 C Nominal diameter ASME[inch] m CIA It DN[mm] o M o voi N N 17 O OD Protection category IP 67 eq.NEMA 6 Iso insertion lenght Conductivity Non-water >_5 µS/cm Water >20 µS/cm Performance Process conditions Liquids with maximum solid particle /gas content<3%(by volume) Inaccuracy(under reference conditions) ±05%of MV Measuring range(see flow table) 0.3...12 m/s(1...40 ft/s) Temperature limits Process temperature See table Ambient temperature See table Storage temperature -50...70°C(-58...158°F) ■standard■optional❑on request Current output Function All operating data configurable,galvanically isolated Standard HART communication For passive mode Current Fixed ranges:4...20 mA Variable ranges for Q=0%,10%=4...14 mA for Q=100%,1100%=10...20 mA for Q>100%,Imax.=21 mA (adjustable in 0,1 mA increments) Error identification(to NE 43) 3.6...4 mA or 20...22,4 mA adjustable in 0,1 mA increments Bidirectional flow measurement Direction identified via status output (forwards/reverse] Binary output Function Selectable at pulse or status output All operating data configurable,galvanically isolated Pulse output Digital pulse division,interpulse period non-uniform,therefore if frequency and cycle meters are connected allow for minimum counting interval: Gate time counter=>10/P100%[Hz] Pulse width:30-1000 ms adjustable in 10 ms increments Status output Configurable as measuring range identification for automatic range change,indicator of flow direction, overflow,errors,trip point or empty pipe indication Passive mode Selectable according NAMUR(DIN 19 234)or as contact: Open:<1 mA current,max.36 V Closed:100 mA,max.voltage drop<2 V www.krohne.com 5 OPTIFLUX 4040 C Time constant Time constant 0.2 to 99.9 seconds Low flow cut-off Cut-off ON-value 1...19% Cut-off OFF-value 2...20% Local display 3-field LCD Display functions Actual flowrate,forward,reverse and sum totalizers(7-digitl and status messages Units Actual flowrate in liter/s,m3/h,US gallons/min or user-defined unit(e.g.US million gallons/dayl Totalizers in liter,m3,US gallons or user-defined unit(e.g.hectoliter) Language English,German,French(others on request) Display Top field:6-character,7 segment numeral and sign display,plus symbols for key acknowledgements. Middle field:4-character,14 segment text display Bottom field:6 markers to identify display in measuring mode and messages of outputs. Power supply Current output(2-wire connection) 4...20 mA via proprietary power supply,14...36 V Power booster(2 x 2 wire connection) Optionally available,for demanding applications.Proprietary power supply 22 mA,14.36 Vdc or to 24 V DC, max.1 W Cable connection 1/2"NPT Optional PF 1/2 Optional M20 x 1,5 Standard Approvals Non-Ex Standard EEx zone 1/2 Optional FM-class I div.1/2 Optional Available approvals for combined flowmeter,OPTIFLUX 4040 C always Field selectable intrinsic safety"i",increased safety"e"or flameproof enclosure"d" Housing Material Die-casted aluminium(polyurethane coated) Ambient temperature -25...60oC/-13...140°F Protection category IP67,equivalent to NEMA 6 6 www.krohne.com OPTIFLUX 4040 C Temperature and pressure limits Ambient temperature PC1: I Process temperature PC]: -25...60 -25...60 imu 0 Ambient temperature PF]: Process temperature PF]: -13...140 -13...140 -13...10/. 3...284 Liner Diameter Max.pressure Vacuum load in mbar abs.at a process temperature[°C]of... [mml [bar] 40 60 70 80 90 100 120 140 180 TFE 10...20 501 in 0 1 0 0 0 PFA 25...150 50 0 0 0 0 0 0 0 0 0 Liner Diameter Max.pressure Vacuum load in psia at a process temperature PF]of... [inch] [psi] 104 140 158 176 194 212 248 284 356 3/8"-3/4" 725 7,3 10,9 14,5 PFA 1"-6" 725 0 0 0 0 0 0 0 0 0 www.krohne.com 7 OPTIFLUX 4040 C Dimensions and weights Nominal size Dimensions[mm] Approx.weight[kg]** DN PN L* H W T 040 [mm] [bar] DIN IS013359 150 150 165 7,5 15 40 150 150 165 121 330 7.5 40 150 150 165 1 9,5 50 40 200 200 218 160 383 10,5 0 40 200 200 235 173 14,5 100 16 250 250 286 233 451 17,5 16 300 300 327 257 MEL 24,5 Nominal size Dimensions for 150 lbs flanges[inches] Approx.weight[lbsl** ASME Pressure L* H W T 040 [inch] [psig] 5 14.72 19 1/2" 284 5.12 8,23 3,5 14.72 19 28 4,3 2" 284 7,87 7.05 6 13,54 25 284 7,87 8,03 7,5 14,53 36 4" 284 9.84 9,49 9 15.98 46 6" 284 11,81 11,69 11 18.19 46 *Total fitting length: Flowmeter supplied with separate grounding rings: dimension L+ 2 x 0.12"+2 x gasket thickness **approx.weigth of meter body with ASME flanges All flanges according ASME B 16.5 Nominal size Dimensions for 150 lbs flanges[mm] Approx.weight[kgl** ASME Pressure L* H W T 040 DN PN 0 1EMNU130 209 88.9 88.9 8,6 15 16 130 209 88,9 88,9 8,6 25 16 150 137 108 11,3 50 16 200 179 152.4 152,4 11,3 0 16 200 204 190,5 16,3 100 16 250 241 228,E 228.6 20,9 16 300 297 279,4 279.4 20,9 *Total fitting length: upplied with separa unding rin s: dimension L+ 2 x 0.12"+2 x gasket thickness MMMMVd-ywth ASME flanges All flanges according ASME B 16.5 8 www.krohne.com OPTIFLUX 4040 C Nominal size Dimensions for 300 lbs flanges[inches] Approx.weight[lbsl** ASME Pressure L* H W T 040 [inch] [psigl* 3/8" 739,5 5.12 8,23 3,75 14,72 Q 8,23 Q 1" 739,5 5.91 5,71 4,87 12,2 Q 739,5 9.85 7,32 6.5 Q 3" 739,5 9,85 8,43 8,25 14,92 Q 739,5 11 1 u 8,25 Q 6" 739,5 12.6 12,44 12,5 18,94 Q *Total fitting length: Flowmeter supplied with separate grounding rings: dimension L+ 2 x 0.12"+2 x gasket thickness. **Approx.weight of Flowmeter with ASME flanges. Flanges according ASME B 16.5. Q on request Nominal size Dimensions for 300 lbs flanges[mm] Approx.weight[kg]** ASME Pressure L* H W T 040 DN PN 209 5,2 Q 15 16 130 209 95,2 374 Q moor 25I Ou 145 123,8 310 Q 50 16 250 186 165.1 351 Q 80 250 209,E 379 Q 100 16 300 254 209.6 419 Q 0 16 320 316 317,4 481 *Total fitting length: Flowmeter supplied with separate grounding rings: dimension L+ 2 x 0.12"+2 x gasket thickness. **Approx.weight gULowmelar w' nges. Flanges according ASME B 16.5. Q on request www.krohne.com 9 OPTIFLUX 4040 C Frontview OPTI FLUX 4040 C Sideview OPTI FLUX 4040 C b C O 040 , � I H L W dimension b dimension c [mml [inch] [mml [inch] IFC 040 converter 136 5,3 208 8,2 10 www.krohne.com � ' 1 1 ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ OPTIFLUX 4040 C KROHNE Overview • Electromagnetic flowmeters • Level measuring instruments • Variable area flowmeters • Pressure gauges • Mass flowmeters • Temperature measuring instruments • Ultrasonic flowmeters • Water solutions & analysis • Vortex flowmeters • Oil and gas turnkey solutions • Flow controllers Addresses: Greatay Germany KROHNE sales KROHNEtain Ltd. KRO NE Norway A.S. Representatives companies Rutherford Drive Ekholtveien 114 Northern sales office Park Farm Industrial Estate NO-1521 Moss Algeria KROHNE Messtechnik GmbH&Co.KG WeLlingborough Phone:+47(0169 264860 Argentina Northants NN86AE Fax+4710)69267333 Cameroon Bremer Str.133 Canada D-21073 Hamburg International Phone4(01+44 1933400119 33 50108 Poland Phone.+49(0)407673340 Fax:+44 10119 33 408 501 Poland Chile Fax:+4910)40 767 33412 infolakrohne.co.uk KROHNE Endra Sp.z.o o. Columbia Australia CIS ul.Sta nek Oliwsiki 8a Croatia nord2krohne.de rY R Y ZIP code:10000-29999,49000-49999 KROHNE Australia Ply Ltd Kanex KROHNE Engineering AG 80-324 Gdansk Denmark Quantum Business Park 10/287 Business-Centre Planeta Phone:+4810)585209211 Ecuador Western and middle sales office Victoria Rd Rydalmere NSW 2116 Office 404 ul. Fax.:+48(0158 520 9212 Egypt KROHNE Messtechnik GmbH&Co.KG Phone:+61 2 8846 1700 Marxistskala 3 wendraszkafakrohne pl. Finland Fax+61288461755 Ludwig-Krohne-StraBe : 109147 Moscow/Russia Switzerland Gabon Ghana D-47058 Duisburgkruhnefakrohne.com.au Phone+7(01095 911 7165 KROHNE AG Phone:+49(01203301416 Austria Fax:+7[010957428873 Wei-Mr.90 Greece Fax:+4910)203 301 10416 KROHNE Austria Ges m b.H krohnetadoL.ru CH-4019 Basel. Hong Kong Hungary west2krohne.de Modecenterstra0e 14 India Phone:«41(0161 638 30 30 Indonesia ZIP code:30000-34999,37000- A-1030 Vienna Krohne Marshall Ltd. Fax+41[0)61 638 30 40 Iran 48000,50000-53999,57000-59999, Phone:+43[011/2034532 A-34/35,M.I.D.C.Industrial Area, infofakrohne.ch Ireland 98000-99999 Fax:+43 10I1/203 47 78 H-Black Singapore Israel infofakrohne.at Pimpri Poona 411018 Tokyo Keiso-KROHNE(Singapore) Ivory Coast Southern sales office Belgium Phone:+91(0)2027442020 Pte.Ltd. Japan KROHNE Messtechnik GmbH&Co.KG KROHNE Belgium N.V. Fax:+91(01202 744 2020 14,International Business Park, Jordan Landsberger Str.392 Brusselstraat 320 pcufdvsnl.net Jurong East Kuwait D-81241 Munich B-1702 Groot Bi)gaarden Iran Chiyoda Building,#01-01/02 Libya Phone+49(01891215620 Phone:+32[012 4 66 00 10 KROHNE Liaison Office Singapore 609922 Lithuania Fax:+4910)891296190 Fax:+32(0)24660800 North Sohrevardi Ave.26, Phone:(6516567 4548 Malaysia suedfdkrohne.de kruhnefakrohne.be Sarmad St.,Apt.#9 Fax:1651 6567 9874 Mauritius ZIP code:0-9999,80000-89999, Brazil Tehran 15539 tksfatukyokeiso-krohne.com.sg Mexico 90000-97999 KROHNE Conaut Controles Phone:+9821 8874 5973 Morocco Republic of South Africa Automaticas Ltda Fax 4821 8850 1268 KROHNE Pty.Ltd. New Zealand Southwestern sales office Estrada Das Aguas Espraiadas,230 krohnefakrohneiran com 163 New Road Peru KROHNE Messtechnik GmbH&Co.KG C.P.56 06835-080 EMBU-SP Italy Halfway House Ext 13 Portugal Rudesheimer Str.40 Phone:+55(0111-4785-2700 KROHNE Italia SrL. Midrand Romania D-65239 Hochheim/Main Fax:+55[0)11 4785-2768 Via V.Monti 75 Phone:+27[0111 315 2685 Saudi Arabia Phone:+4q(0)6146)82730 conautfdconaut com br 1-20145 Milan Fax:+27(0)118050531 Senegal Fax:+4910)6146827312 China Phone:+3910)2 43 30 06 61 midrandfakrohne.co.za Slovakia rhein-mainfakrohne.de KROHNE Measurement Instruments Fax+39(012 43 00 66 66 Slovenia ZIP code:35000-36999,54000- Spain Sweden )Shanghai)Co.Ltd.,IKMICI info2krohne.it 1 1.KROHNE IBERIA,S.r L.56999,60000-79999 Taiwan Room 1501 Korea PoLigono Industrial Nile 1033 Zhaoliabang Road KROHNE Korea Calle Brasil,n°.5 Thailand Instrumentation and control Tunisia equipment catalog Shanghai 200030 Room 508 Miwon Bldg 43 28806 Alcala de Henares Madrid Turkey Phone:+86 21 6487 9611 Yoido-Dong Youngdeungpo-Ku Phone:+3410)918832152 wi-MesstechnikKrohne-Stra0 5 e Fax:+86 21 6438 7110 Seoul,Korea Fax: 3410I918834854 Yugoslavia Venezuela L d + u wig v infofdkrohne-asia.com Phone:00-82-2-780-1743 krohne2krohne.es ar D-47058 Duisburg w Phone:+49(012 03 305 880 Czech Republic Fax 00-62-2-780-1749 USA Fax:+49 10)2 03 305 8888 Sobisicka 156 krohnekoreardkrohnekorea.com KROHNE,Inc. kontakt2tablar.de www tablar.de 63800 Brno Netherlands 7Dearborn Road ter countries Phone:+420[01545.242627 KROHNE Nederland B.V. Peabody,MA 01960 Fax:+420(0)545220093 KerkepLaat 14 Phone:+118001 FLOWING KROHNE Messtechnik GmbH&Co.KG brnofdkrohne.cz NL-3313 LC Dordrecht Phone:+1 19781 535 6060(in MAI Ludwig-Krohne-Str.5 France Phone+31(01786306200 infofdkrohne.com D-47058 Duisburg KROHNE S.A.S. Fax:+31 10178 630 6405 Phone+49(0)203 301 0 o Les Ors BP 98 Service Direct:+31 10)78 630 6222 O Fax:+49(01203 301 389 N F-26103 ROMANS Cedex infulakrohne.nl exportfakrohne.de Phone+33 1014 75 05 44 00 uoi Fax+33(014 75 05 00 48 o infotakrohne.fr t; 0 0 N v O W Z 2 O fY KROHNE 12 www.krohne.com