TD_OPTIFLUX 5000__us__050511_7024992100_R00
Technical Data Sheet KR O H N E ©KROHNE 10/2004 7.02497.21.00 GR/PRIWO OPTIFLUX 5000 Electromagnetic Flow Sensor The most accurate and abrasion resistant flowmeter 0.15 % accuracy For most aggressive and abrasive fluids Full vacuum resistant For dosing applications 196/ r \1PPO 1 r Electromagnetic flowmeters Variable area flowmeters Mass flowmeters `. Ultrasonic flowmeters Vortex flowmeters Flow controllers Level measuring instruments Pressure and temperature Heat metering Communications technology Switches,counters,displays and recorders Engineering systems&solutions Subject to change without notice. OPTIFLUX 5000 The most accurate and abrasion resistant Fields of application The electromagnetic flow sensor OPTIFLUX 5000 is considered to be the most accurate and hard-wearing,robust flowmeter available in the market today.This is the result of a Industries special flow tube design with conical parts,streamlining distorted flow profiles. • Chemical Leading test institutes use OPTIFLUX 5000 as their master meter. • Water&Wastewater • Metals& Mining • Food & Beverages • Paper& Pulp • Machinery 0.15% bj accuracy Application examples • Precise dosing applications 10, • For acids(even HF),alkalies, pastes,slurries and many other aggressive media,even with high a solid contents • Master or transfer meter for calibration of other flow-meters k DIN 2.5...100 Ceramic L \ liner Stainless steel housing OPTIFLUX 5000 The most accurate and abrasion resistant Highlights • Highly accurate • Long-term measuring stability even under tough conditions ♦ —"' • Highly corrosive and abrasive resistant • Robust and dimensionally stable • Sandwich design for quick and easy installation • Absolutely vacuum resistant Product features • Accuracy: < ±0.15% of measured value • Repeatability: < 0.06% • Unique flow tube design,with profile-optimizing cross-section • Ceramic flow tube • Fused-in-place Cermet or platinum electrodes; bonded electrodes in the flow tube are absolutely t ` leakproof ¢ • Stainless steel housing -* KRONNE � 2 OPTIFLUX 5000 The complete OPTIFLUX - range OPTIFLUX converters All converters fit to all sensors IFC 300 IFC 010 One for all applications Economic converter it! IIIf C(.I I F W C W • OPTIFLUX sensors OPTIFLUX 2000 OPTIFLUX 4000 OPTIFLUX 5000 Water and waste- All-round process Highly accurate & water specialist specialist abrasion resistant ,5t- OPTIFLUX 1000 OPTIFLUX 6000 Economical Sanitary and solution hygienic solution rIw11► ,��r/► Special-purpose flowmeters OPTIFLUX 4040 C OPTIFLUX 7300 C TIDALFLUX 4110 PF BATCHFLUX 5015 C The 2-wire EMF The electrode-free For partially filled For volumetric filling EMF pipelines M KRUNNE OPTIFLUX 5000 3 The responsibility as to the suitability,intended use and corrosion resistance of the materials used in their construc- tion rests solely with the purchaser. Technical data • Standard O Optional On request Nominal o ao v So e�j - % iN e+> v m ao 0 diameter ANSI[inch] — M Cn pp'e Co o lA N Q � W O CD O C' DN[mm] N N N Nominal process EN 1092-1-PN 40 • • • • • • • • 1 • - flange pressure EN 1092-1-PN 25 - - - O - 1/10:...3/8"has 1/2" EN 1092-1-PN 16 - - • • - connection(DN EN 1092-1-PN 10 - - - - • • 2.5...10 has DN 15 ANSI B16.5-150 lbs/JIS 10 K • • • • • • • • • • • • • connection) ANSI B16.5-300 Ibs/JIS 20 K 1 O 1 O 1 O 1 O 1 O 1 O O O O O - - Measuring tube Aluminum Oxide(A1203),W2 stabilized • • • • • • • • • • • • • Electrodes Cermet • • • • • Platinum - - - - - • • • • • O O O Stainless steel 1.4571(316 Ti) - - - - - • • • HC4,Low-noise(basis HC4,Ta,Ti) - - O O O Rings I gaskets Stainless steel 1.4571(AISI 316 Ti)/Viton • • • • • - - Withoutl GyIon - - - - - • • • • • (all rings always Stainless steel 1.4404(AISI 316 L)I Viton - - - - - - - • • • type#1) Hastelloy C4/Viton O O O O O - - O O O HC4/EPDM,HC4/Kalrez,stst 1.4571(Aisl O O O O O - - - - - - - - 316Ti)l EPDM,Ti/EPDM,Ti/Kalrez Tantalum/PTFE-PF 29 O 0 0 O O O O O O O Without/Chemotherm,HC4/Chemotherm, O O HC4/GyIon,stst/Chemotherm,stst/GyIon O O O Stud bolts and Steel • • • • • • • • • • nuts** Stainless steel,Rubber centering sleeves FtP 0 0 0 O O 0 0 0 O **Gaskets not included. Flanges Steel 37-C22 • • • Materials used Measuring tube High density Aluminum oxide(AI203),Zr02 fine grain stabilized (other materials on Housing(polyurethane coated) Stst 1.44621Duplex F Stst 1.43011SS 304-AISI Steel request) Connection box(polyurethane coated) Die-cast aluminum(Option:Stainless steel) Protection Standard IP 66/67 eq.NEMA 414X16 category Optional IP 68 field/IP 68 factory eq.NEMA 6(Connection box:Stainless steel) Insulation class H Approvals**** non-Ex • • • • • • • • • • • • • EEx zone 112 O O O O O O O O O O - - - FM-class I div.112***** O O O O O O O O O O - - - CSA-GP/class I div. 112***** O 0 0 0 O O 0 0 0 O - - - SAA-Aus Ex zone 1 l 2 O O O O O O 0 0 0 O - - - TIS-zone1/2 O O O O O O 0 0 0 O ****Available approvals for flow sensor. Note: contact KROHN E for more approval details Versions Compact+IFC 300 C • • • • • • • 01 • • Separate+IFC 300 F,R,W • • • • • • • • • • • • • Compact+IFC 010 C(non-Ex) • • • • • • • • • Separate+IFC 010 W(non-Ex) • • • • • • • • • Vacuum load 0 psig/0 mbar absolute Electrical Non-water(DN 2.5>_ 10µSlcm) >_5µS/cm >_ 1 µSlcm conductivity Demineralised cold water >_20µSlcm ***** Approvals should read the same as OPTFLUX 2000 KRONNE � 4 OPTIFLUX 5000 Temperature range 1/10...If. Process Ambient DN 2.5...100 Process Ambient min. I max. min. I max. min. I max. min. I max. A1203 A1203 Separate flow sensor -76°F 356°F -40°F 149°F Separate flow sensor -60°C 180°C -40°C 65°C Compact with IFC 300 Compact with IFC 300 OPTIFLUX 5300 C 76°F 284°F 40°F 149°F OPTIFLUX 5300 C 60°C 140°C 40°C 65°C Compact with IFC 010 Compact with IFC 010 OPTIFLUX 5010 C 13°F 248°F 13°F 140°F OPTIFLUX 5010 C 25°C 120°C 25°C 60°C 6"...10" Process Ambient DN 150...250 Process Ambient min. I max. min. I max. min. max. min. I max. A1203 A1203 Separate flow sensor I -76°F I 248°F -13°F I 140°F Separate flow sensor -60°C I 120°C -25°C I 60°C Max.permissible temperature change in°F Max.permissible temperature change in°C 10 minutes Sudden change 10 minutes Sudden change 1110"-112" 1"-4" 1110%1/2" 1"-4" DN 2.5-15 1 DN 25-100 DN 2.5-15 DN 25-100 Rising 302 302 248 248 Rising 150 150 120 120 Falling 248 212 194 176 Failing 120 100 90 80 � KRONNE OPTIFLUX 5000 5 Dimensions and weights OPTIFLUX 5000 F Nominal size Dimensions in inches Approx. 111mm,44„ 106 mm 4.2' T weight ANSI [psig] L* H W - E 0.7 k011.5m Tbox T010 T300 in Ibs** 1/10" 580 2,56 4,84 1,73 7,87 8,98 10,94 3,5 x 0 1/8" 580 2,56 4,84 1,73 7,87 8,98 10,94 3,5 _ 1/4" 580 2,56 4,84 1,73 7,87 8,98 10,94 3,5 3/8" 580 2,56 4,84 1,73 7,87 8,98 10,94 3,5 1/2" 580 2,56 4,84 1,73 7,87 8,98 10,94 3,5 L w 1" 580 2,28 4,57 4,02 7,60 8,70 10,67 3,5 11/2" 580 3,27 5,16 4,61 8,19 9,29 11,26 5,3 2" 580 4,06 5,87 5,31 8,90 10,00 11,97 6,4 OPTIFLUX 5010 C 3" 580 6,02 7,13 6,57 10,16 11,26 13,23 14,1 4" 2321 7,99 8,11 7,56 11,14 12,24 14,21 19,4 160mm16.3" 140mm15.5" 6" 145 10,43 14,21 11,14 20,31 - 81,6 8" 145 12,40 15,82 13,46 21,92 116,8 E 1sk913sib o 0 10" 145 14,37 18,26 16,02 24,36 191,8 All flanges according ANSI B 16.5. < ANSI 4"flangeless(sandwich)version; >_ANSI 6"flanged version. _ - _+- - _ *Total fitting length: ANSI 1/10"-1/2" flowmeter with integrated rings: Dim. L+2x gasket thickness. ANSI V-4" flow meter without rings: Dim. L only (no gaskets required). w ANSI 6"-10" flow meter with separate rings: Dim. L+2 x 0.12+2 x gasket thickness. Approx.weight of meter body. OPTIFLUX 5300 C Nominal size Dimensions in mm Approx. 202 mm 17.75" 260 mm/10.2" DN PN L* H W T weight ?0mm14.75' 1 137M 15.4' [mm] [bar] Tbox T010 T300 in kg** 2,5 40 65 123 44 200 228 278 1,6 4ME 4.2 kg 19.31b - 4 40 65 123 44 200 228 278 1,6 6 40 65 123 44 200 228 278 1,6 10 40 65 123 44 200 228 278 1,6 15 40 65 123 44 200 228 278 1,6 + 25 40 58 116 102 193 221 271 1,6 40 40 83 131 117 208 236 286 2,4 L w 50 40 103 149 135 226 254 304 2,9 80 40 153 181 167 258 286 336 6,4 100 16 203 206 192 283 311 361 8,8 150 10 265 355 283 432 37 200 10 315 396 342 473 53 250 10 365 458 395 535 87 All flanges according(EN 1092-1). <_ DN 100 flangeless(sandwich)version; >_ DN 150 flanged version. *Total fitting length: DN 2.5-15 flowmeter with integrated rings: Dim. L+2x gasket thickness. DN 25-100 flow meter without rings: Dim. L only (no gaskets required). DN 150-250 flow meter with separate rings: Dim. L+2 x 3 mm+2 x gasket thickness **Approx.weight of meter body. KRONNE � 6 OPTIFLUX 5000 JKROHNE�74 hftp://www.krohne.comProduction :r a Irkutsk T"PF UISBURGfr" ■ Peatady/MA■- - Wei Hanitud • a Moseow Chengde Beijing Grodno ^ Dordrecht ■ —w mere' Yokohama Groot Bijgaarden■ •HochheimJMatn Kiew •Munich ■Brno - --- Basel ■Vienna �yT -"•Shanghai Ro Madrid Milano Poona Hong Kong r .� 10�w KROHNE Emlw,Brazil .� lalrlrlaeburg,SA Australia fF-26103 rance Netherlands United Kingdom KROHNE Australia Pty Ltd ROHNE S.A.S. KROHNE Nederland B.V. KROHNE Ltd. Castle Hill,NSW Quantum Business Park es Ors Kerkeplaat 14 Rutherford Drive • 10/287 Victoria Rd P 98 NL-3313 LC Dordrecht Park Farm Industrial Estate Rydalmere NSW 2116 ROMANS Cedex TEL.:+31(0)78-6306200 Wellingborough, TEL.:+612 8846 1700 EL:+33(0)4-75 05 44 00 FAX:+31(0)78-6306405 Northants NN8 6AE,UK ' FAX:+61 2 8846 1755 '.� FAX:+33(0)4-75 05 00 48 Service Direkt+31(0)78-6306222 TEL.:+44(0)19 33-408 500 e-mail:krohne@krohne.com.au e-mail:info@krohne.fr e-mail:info@krohne.nl FAX:+44(0)19 33-408 501 Austria e-mail:info@krohne.co.uk KROHNE Austria Ges.m.b.H. Germany Norway KROHNE Messtechnik KROHNE Norway A.S. USA Modecenterstra8e 14 GmbH&Co.KG Ekholtveien 114 KROHNE Inc. A-1030 Wien Ludwig-Krohne-StraBe NO-1526 Moss 7 Dearborn Road TEL.:+43(0)1/203 45 32 D-47058 DuisburgP.O.Box 2178,NO-1521 Moss FAX:+43(0)1/203 47 78 Peabody,MA e-mail:info@krohne.at TEL.:+49(0)203-301-0 TEL.:+47(0)69-264860 TEL.:+1-978 535-6 535-6060 FAX:+49(0)203-301-10 389 FAX:+47(0)69-267333 FAX:+1-978 535-1720 Belgium e-mail:krohne@krohne.de e-mail:postmaster@krohne.no e-mail: info@krohne.com KROHNE Belgium N.V. Internet www.krohne.no Brusselstraat 320 India B-1702 Groot Bijgaarden KROHNE Marshall Ltd. Singapore Overseas Representatives TEL.:+32(0)2-4 66 00 10 A-34/35,M.I.D.C. Tokyo Keiso-KROHNE Singapore Pte.Ltd. pre FAX:+32(0)2-4 66 08 00 Industrial Area,H-Block, 14,International Business Park, Algeria Kuwait e-mail:krohne@krohne.be Pimpri Poona 411018 Jurong East Argentina Libya TEL:+91(0)202-7442020 Chiyoda Building#01-01/02 Belarus Lithuania Brazil FAX:+91(0)202-7442020 Singapore 609922 KROHNE Conaut e-mail:pcu@vsnl.net Singapore Cameroon Malaysia Controles Automaticos Ltda. TEL.:++65-65-67-4548 Canada Morocco Estrada Das Aguas Espraiadas,230 C.P.56 Iran FAX;++65-65-67-9874 Chile Mauritius 06835-080 EMBU-SP KROHNE Liaison Office Colombia Mexico TEL.:+55(0)11-4785-2700 North Sohrevardi Ave. South Africa Croatia New Zealand FAX:+55(0)11-4785-2768 26,Sarmad St.,Apt.#9 KROHNE Pty.Ltd. Denmark Peru e-mail:conaut@conaut.com.br Tehran 15539 163 New Road Ecuador Poland Egypt Portugal China TEL:++98_21-874-5973 Hallway House Ext.13 Finland Romania KROHNE Measurement Instruments FAX:++98-21-850-1268 Midrand Gabon Saudi Arabia (Shanghai)Co.Ltd.,(KMIC) e-mail:krohne@krohneiran.com TEL.:+27(0)11-315-2685 Ghana Senegal Room 1501,TowerA FAX:+27(0)11-805-0531 Greece Slovakia Italy City Centre of Shanghai e-mail:midrand@krohne.co.za Hong Kong Slovenia 100 Zun Yi Road KROHNE Italia Sri. Hungary Sweden Via V.Monti 75 Shanghai 200051 Spain Indonesia Taiwan I-20145 Milano I.I.KROHNE Iberia,S.r.L. TEL.:+86 21 6237 2770 Ivory Coast Thailand FAX:+86 216237 2771 TEL:+39(0)2-4 30 06 61 Paligono Industrial Nilo Iran Turkey FAX:+39(0)2-43 00 66 66 Celle Brasil,n°.5 Cellphone:+86(0)139 01954185 e-mail:info@krohne.it Ireland Tunisia e-mail:info@krohne-asia.com E-28806 AlcalB de Henares-Madrid Israel Venezuela TEL.:+34(0)91-8 83 2152 Japan pan Yugoslavia CIS FAX:+34(0)91-8 83 48 54 Kanex KROHNE Engineering AG KROHNE Korea e-mail:krohne@krohne.es Jordan Business-Centre Planeta,Office 404 Room 508 Miwon Bldg ul.Marxistskaja 3 43 Yoido-bong Switzerland 109147 Moscow/Russia Youngdeungpo-Ku KROHNE AG Other Countries: TEL.:+7(0)095-9117165 Seoul,Korea Uferstr.90 GmbH&Co.KG KROHNE Messtechnik FAX:+7 0 095-7428873 TEL:00-82-2-780-1743 ( ) FAX:00-82-2-780-1749 C Basel e-mail:krohne@dol.ru TELL.:.:+41g1(0)61-638 30 30 Ludwig-Krohne-Str. e-mail:krohnekorea@krohnekorea.com FAX;+g1(0)61-638 30 40 8 Duisburg TEL: 4 Czech Republic e-mail:info@krohnech TEL.:+ 9(0)203-301-0 . KROHNE CZ,spol.s r.o. Netherlands FAX:+49(0)203-301 389 Sobd§icka 156 KROHNE Altometer e-mail:expon@krohne.de CZ-63800 Brno Kerkeplaat 12 TEL.:+420 545 532 111 NL-3313 LC Dordrecht FAX:+420 545 220 093 TEL:+31(0)78-6306300 e-mail:brno@krohne.cz FAX:+31(0)78-6306390 Subject to change without notice e-mail:postmaster@krohne-altometer.nl