Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
TD_OPTIFLUX 6000__us__050511_7024982100_R00
Technical Data Sheet KR O H N E ©KROHNE 10/2004 7.02498.21.00 ■ - GR/PRIMO OPTIFLUX 6000 Electromagnetic flow sensor for sanitary and hygienic applications OP IM r l c _ I --+ Electromagnetic flowmeters Variable area flowmeters Mass flowmeters Ultrasonic flowmeters Vortex flowmeters KppH ENEN Flow controllers Level measuring instruments Pressure and temperature Heat metering Communications technology '° Switches,counters,displays and recorders L Q Engineering systems&solutions nC I IC DG= d�3 d Subject to change without notice. OPTIFLUX 6000 The sterile solution Fields of application The OPTIFLUX 6000 electromagnetic flow sensor is the solution for all sanitary applications. Industries • Food & beverage • Pharmaceuticals • Chemical i Application examples Keeps in shape Blending,dosing and batching • Improved design with calculated stress points • Critical sanitary and hygienic • Superior mesh support Highest quality applications stainless steel • From drugs and intermediates to Whatever connector soft drinks,milk,beer,and fruit you prefer r juices •Industry-standard body length • For use in large-scale production •All popular industry e plants with wide diameter range connectors with 1 up to 6"/ DIN 150 simply bolt-on design -.. Outside finish New gasket concept rounded edges OPTIFLUX 6000 has a unique L-shaped gasket,which Stays smooth,stays sterile when compressed,shows • Unique gasket design with unidirectional compression. Our non-stick stays innovative expansion chamber non-stick • Unidirectional compression will • Improved surface not allow gasket to expand into smoothness measuring tube • Improved internal design OPTIFLUX 6000 The sterile solution Highlights Gasket insert,uncompressed,the trapezoidal form is clearly visible. • Completely sanitary design in stainless steel • Fully suitable for SIP and CIP • Typical food & beverage and pharmaceutical process connections and insertion lengths • FDA approved, EHEDG & 3A certified Product features Meter fitted,gasket compressed, • Unique L-shaped gasket prevents expansion of at room temperature. The greatest compression pressure is the gasket into the measuring tube at the measuring tube end of the gasket,forcing it to expand only into • Simple and effective SIP (Steaming in Place) the expansion chamber. and CIP (Cleaning in Place) • Cleaning temperatures depending from the process connection up to 300OF/ 150'C • Large diameter range up to 6"/DN 150 • Low weight Elevated temperature with meter • Conductivity fitted and gasket compressed. -�► - non water> 1 CIS/cm The compression chamber is almost completely filled.The gasket does not —� - water> 20 uS/cm bulge excessively into the measuring KROHNE tube. 2 OPTIFLUX 6000 The complete OPTIFLUX - range OPTIFLUX converters All converters fit to all sensors IFC 300 IFC 010 One for all applications Economic converter Lq • C F W 19 C W • OPTIFLUX sensors OPTIFLUX 2000 OPTIFLUX 4000 OPTIFLUX 5000 Water and waste- All-round process Highly accurate & water specialist specialist abrasion resistant OPTIFLUX 1000 OPTIFLUX 6000 Economical Sanitary and solution hygienic solution Special-purpose flowmeters OPTIFLUX 4040 C OPTIFLUX 7300 C TIDALFLUX 4110 PF 13ATCHFLUX 5015 C The 2-wire EMF The electrode-free For partially filled For volumetric filling EMF pipelines r KROHNE OPTIFLUX 6000 3 The responsibility as to the suitability,intended use and corrosion resistance of the materials used in their construc- tion rests solely with the purchaser. Technical data • Standard O Option On request Nominal ANSI Inch o c2o � M N � N � C C i°n cc C [inch] - N diameter pp N tD O LO ul�N 11'f t�0 coC O N DN[mm] `" Process DIN 11850 • • • • • • • • • • • • • Connections DIN 11851 0 0 0 0 0 0 0 0 0 0 0 0 0 DIN 11864-2A - - - - - 0 0 0 0 0 0 0 0 DIN 32676 - - - 0 0 0 0 0 0 0 0 ISO 2037 • • • • • • • • • • • • • IS0 2852 0 0 0 0 0 0 0 0 0 0 0 0 0 SMS 1145 - - - - 0 0 0 0 0 0 0 0 TRI CLOVER - - 0 0 0 0 0 0 0 0 Notes:DN 2.5-6(1/10-1/4")have DN 10(3/8")connections. Liner* PFA • • • • • • • • • • • • • *See temperature limits. Electrodes Hastelloy C4 • • • • • • • • • • • • • Hastelloy B2 0 0 0 0 0 0 - - - - - - Platnum 0 0 0 0 0 0 - - - - - - - Stainless steel 1.4404(AISI 316 L) - - - - - 0 0 0 0 0 0 Stainless steel 1.4571 (AISI 316 Ti) 0 0 0 0 0 0 - Tantalum 0 0 0 0 0 0 1 -- Titanium 0 0 0 0 0 0 0 0 0 0 0 0 0 Integrated Without/EPDM • • • • • • • • • • • 1 • • rings/gaskets Without/silicone 0 0 0 0 0 0 0 0 0 0 0 0 0 Materials used* Measuring tube Austenitic stainless steel Adapters Stainless steel 1.4404(AISI 316 L) Housing Stainless st 1.4462(Duplex)F Stainless steel 1.4301 (AISI 304) Terminal box standard Die-cast aluminum(polyurethane coated) Terminal box optional Stainless steel 1.4301 (AISI 304) *Other materials on request Protection Standard IP 66/67 eq.N EMA 4/4X/6 category Optional I 68 field /I 68 factory eq, N E M A 6P Insulation class H Sanitary 3A • • • • • • • • • • • • • approvals EHEDG • • • • • • • • • • 1 • • • Versions Compact+IFC 300 C • • • • • • • • • • • • • Separate+IFC 300 F, R,W • • • • • • • • • • • • • Compact+IFC 010 C - - - • • • • • • • • • • Separate+IFC 010 W - - • • • • • • • • • • Vacuum load 0 mbar/0 psi absolute Electrical Non-water I >_ 5µS/cm >_ 1,uS/cm(IFC 300,5µS/cm with IFC 010) conductivity Water >_20µS/cm KROHNE � 4 OPTIFLUX 6000 Temperature range Flow sensor Process temperature Ambient temperature min. max. min. max. PTFE/PFA -40°C 180°C VC WC Compact flowmeter Process temperature Ambient temperature min. max. min. max. with IFC 300 -40°C 140°C -40°C 65°C with IFC 010 -25°C 120°C -25°C 60°C Flow sensor Process temperature Ambient temperature min. max. min. max. PTFE/PFA -40°F 356°F -40°F 149°F Compact flowmeter Process temperature Ambient temperature min. max. min. max. with IFC 300 -40°F 284°F -40°F 1497 with IFC 010 -13°F 248°F -13°F 140°F Dimensions and weights 160 mm 16.3" 140 mm/5.5" N R 1.6kg13.51b E 202 mm 17.75" 260 mm/10.2" 120 mm 14.75 137mm15." 0 0 - O ° o 4.2 kg/9.31b 0 E o 0 111mm/4.4" 1 6mm142" 0.7kg/1.51b tot _t O L W KRUHNE OPTIFLUX 6000 5 OPTIFLUX 6000 Dimensions and weights Aseptic weld-on for pipes to DIN 11850 Nominal size Dimensions in mm Adapter dimensions Flowmeter dimensions Approx. DN PN* T weight _.� __ �i G di G la L H W in kg** [mm] [bar] T box TIFC010 TIFC300 Screwed adapter 2.5 40 10 13 32 180 123 44 200 278 1.5 a L 4 40 10 13 32 180 123 44 200 278 1.5 6 40 10 13 32 180 123 44 200 278 1.5 10 40 10 13 32 180 123 44 200 228 278 1.5 15 40 1 16 19 32 180 123 44 200 228 278 1.5 Bolted adapter 25 40 26 29 21 133 128 89 205 233 283 3.0 40 40 38 41 61 220 153 114 230 258 308 5.3 50 25 50 53 61 220 153 114 230 258 308 6.8 65 25 66 69 42 220 180 141 257 285 335 10.9 80 25 81 84 67 280 191 152 268 296 346 11.2 100 16 100 103 59 280 242 203 319 347 397 18.4 125 10 125 128 66 319 258 219 335 363 413 on 150 10 150 153 64 325 293 254 370 398 448 request *Pressure limits for complete temperature range equal maximum pressure rating indicated. **Approx.weight of meter body with adapters. Dairy screw to DIN 11851 Dimensions in mm Nominal size Approx. Adapter dimensions Flowmeter dimensions DN PN* T weight di G la L H W in kg** [mm] [bar] T box TIFca1a TIFC300 di G Screwed adapter 2.5 40 10 Rd 28 x 1/8" 53 214 123 44 200 278 1.5 4 40 10 Rd 28 x 1/8" 53 214 123 44 200 278 1.5 6 40 10 Rd 28 x 1/8" 53 214 123 44 200 278 1.5 L la 10 40 10 Rd 28 x 1/8" 53 214 123 44 200 228 278 1.5 15 40 1 16 Rd 34 x 1/8" 53 214 123 44 200 228 278 1.5 Bolted adapter 25 40 26 Rd 52 x 1/6" 49 190 128 89 205 233 283 3.2 40 40 38 Rd 65 x 1/6" 91 280 153 114 230 258 308 5.5 50 25 50 Rd 78 x 1/6" 93 284 153 114 230 258 308 5.3 65 25 66 Rd 95 x 1/6" 78 292 180 141 257 285 335 10.0 80 25 81 Rd 110 x 1/4" 108 362 191 152 268 296 346 12.5 100 16 100 Rd 130 x 1/4" 109 380 242 203 319 347 397 21.8 125 10 on 258 219 335 363 413 on 150 10 request 293 254 370 398 448 request *Pressure limits for complete temperature range equal maximum pressure rating indicated. **Approx.weight of meter body with adapters. KROHNE � 6 OPTIFLUX 6000 OPTIFLUX 6000 Dimensions and weights Screwed pipe connection to SMS 1145 Nominal size Dimensions in mm Adapter dimensions Flowmeter dimensions Approx. DN PN weight di G la L H W in kg** --- -- -- al c [mm] [bar] T box TIFC010 TIFc300 25 6 23 Rd 40 x 1/6" 28 148 128 89 205 233 283 3.2 40 6 36 Rd 60 x 1/6" 54 262 153 114 230 258 308 5.7 50 6 49 Rd 70 x 1/6" 84 266 153 114 230 258 308 5.4 L la 65 6 60 Rd 85 x 1/6" 70 276 180 141 257 285 335 9.9 80 6 73 Rd 98 x 1/6" 100 346 191 152 268 296 346 12.1 100 6 98 Rd 132 x 1/6" 44 336 242 203 319 347 397 21.9 *Pressure limits for complete temperature range equal maximum pressure rating indicated. **Approx.weight of meter body with adapters. Sanitary flange to DIN 11864-2A Nominal size Dimensions in mm Approx. Adapter dimensions Flowmeter dimensions 8 T weight DN PN* di G la L H W in kg** d. c T box I TIFC010 TIFC300 25 40 26 70 46 183 128 89 205 233 283 4.4 40 40 38 82 83 264 153 114 230 258 308 7.5 L la 50 25 50 94 83 264 153 114 230 258 308 9.0 65 25 66 113 64 264 180 141 257 285 335 14.5 80 25 81 133 123 392 191 152 268 296 346 18.6 100 16 100 159 115 392 242 203 319 347 397 28.2 125 10 on 258 219 335 363 413 on 150 10 request 293 254 370 398 448 request *Pressure limits for complete temperature range equal maximum pressure rating indicated. **Approx.weight of meter body with adapters. Clamp joint to DIN 32676 Dimensions in mm Nominal size Approx. Adapter dimensions Flowmeter dimensions weight l DN PN* di G la L H W T in kg** - — — -- -- di c [mm] [bar] T box TIFC010 TIFC300 25 16 26 50.5 42 190 128 89 205 233 283 3.2 40 16 38 50.5 81 280 153 114 230 258 308 5.5 la- 50 16 50 64.0 81 284 153 114 230 258 308 5.3 65 16 66 91.0 68 292 180 141 257 285 335 10.0 80 16 81 106.0 93 362 191 152 268 296 346 12.5 100 16 100 119.0 85 380 242 203 319 347 397 21.8 *Pressure limits for complete temperature range equal maximum pressure rating indicated. **Approx.weight of meter body with adapters. � KRUHNE OPTIFLUX 6000 7 Clamp joint to TRI-CLOVER Nominal size Dimensions in mm Adapter dimensions Flowmeter dimensions Approx. DN PN* T weight _ _ di G di G la L H W i [mm] [bar] T box TIFC010 TIFC300 in kg** 25 20 22 50.4 26 190 128 89 205 233 283 3.2 40 20 34 50.4 88 280 153 114 230 258 308 5.5 L Ia 50 20 47 63.9 88 284 153 114 230 258 308 5.3 65 20 60 77.4 68 292 180 141 257 285 335 10 80 20 73 90.0 93 362 191 152 268 296 346 12.5 100 12 97 118.9 86 380 242 203 319 347 397 21.8 *Pressure limits for complete temperature range equal maximum pressure rating indicated. **Approx.weight of meter body with adapters. Aseptic weld-on for pipes to ISO 2037 Nominal size Dimensions in mm Approx. Adapter dimensions Flowmeter dimensions DN PN* T weight PI di G la L H W in kg** T [mm] [bar] T box TIFC010 TIFC300 Screwed adapter 2.5 40 10.0 12.0 32 180 123 44 200 278 1.5 4 40 10.0 12.0 32 180 123 44 200 278 1.5 6 40 10.0 12.0 32 180 123 44 200 278 1.5 10 40 10.0 12.0 32 180 123 44 200 228 278 1.5 151 40 1 15.2 17.2 32 180 123 44 200 228 278 1.5 Bolted adapter 25 40 22.6 25.0 21 133 128 89 205 233 283 3.0 40 40 35.6 38.0 61 220 153 114 230 258 308 5.3 50 25 48.6 51.0 61 220 153 114 230 258 308 5.0 65 25 60.3 63.5 42 220 180 141 257 285 335 9.0 80 25 72.9 76.1 67 280 191 152 268 296 346 10.8 100 16 97.6 101.6 59 280 242 203 319 347 397 18.4 125 10 110.3 114.3 66 319 258 219 335 363 413 on 150 10 135.7 139.3 64 325 293 254 370 398 448 request *Pressure limits for complete temperature range equal maximum pressure rating indicated. **Approx.weight of meter body with adapters. KROHNE � 8 OPTIFLUX 6000 Clamp joint to ISO 2852 Nominal size Dimensions in mm Adapter dimensions Flowmeter dimensions Approx. DN PN* di G la L H W T weight _ -- -- ----- di c ** [mm] [bar] T box TIFC010 TIFC300 in kg Screwed adapter 2.5 16 10.0 34.0 52 219 123 44 200 278 1.5 a L 4 16 10.0 34.0 52 219 123 44 200 278 1.5 6 16 10.0 34.0 52 219 123 44 200 278 1.5 10 16 10.0 34.0 52 219 123 44 200 228 278 1.5 15 16 15.2 34.0 52 219 123 44 200 228 278 1.5 Bolted adapter 25 16 22.6 50.5 42 175 128 89 205 233 283 3.3 40 16 35.6 50.5 88 273 153 114 230 258 308 5.4 50 16 48.6 64.0 88 273 153 114 230 258 308 5.2 65 10 60.3 77.5 68 273 180 141 257 285 335 9.5 80 10 72.9 91.0 93 333 191 152 268 296 346 11.2 100 8 97.6 119.0 86 333 242 203 319 347 397 19.1 125 5 on 258 219 335 363 413 on 150 5 request 293 254 370 398 448 request *Pressure limits for complete temperature range equal maximum pressure rating indicated. '*Approx.weight of meter body with adapters. � KROHNE OPTIFLUX 6000 9 KROHNE � � KRONNE hftp:i/www.kirohne.com Productior i Irkutsk yam' UISBURG 0 s� We - Hamburg • •Moscow Cnengde I nig Pea /bW llln ■ ___ Bat1 _ Grodno •__Seoul Dordrecht ■ amara Yokohama ` Groot en■ ■Hochheim/Main --- `]l` ■Munich ■Brno -- � • -■T --- _ ■Shanghai Basel ■Vienna .� no `�� Fft—on'.1 Hong Kong -• r 4 KROHNE - - Embu,Brazil ■ Johannesburg,SA Australia France Netherlands United Kingdom KROHNE Australia Ply Ltd KROHNE S.A.S. KROHNE Nederland B.V. KROHNE Ltd. Castle Hill,NSW Quantum Business Park Les Ors Kerkeplaat 14 Rutherford Drive • 10/287 Victoria Rd BP 98 NL-3313 LC Dordrecht Park Farm Industrial Estate Rydalmere NSW 2116 F-26103 ROMANS Cedex TEL.:+31(0)78-6306200 Wellingborough, TEL.:+61 2 8846 1700 TEL.:+33(0)4-75 05 44 00 FAX:+31(0)78-6306405 Northants NN8 6AE,UK FAX:+61 2 8846 1755 FAX:+33(0)4-75 05 00 48 Service Direkt:+31(0)78-6306222 TEL.:+44(0)19 33-408 500 e-mail:krohne@krohne.com.au e-mail:info@krohne.fr e-mail:info@krohne.nl FAX:+44(0)19 33-408 501 Austria e-mail:info@krohne.co.uk KROHNE Austria Ges.m.b.H. Germany Norway ModecenterstraBe 14 GmKROHNE Messtechnik KROHNE Norway A.S. USA A-1030 Wien GmbH&Co.KG Ekholtveien 114 KROHNE Inc. A-1 0 Wien 1/203 45 32 Ludwig-Krohne-Strafie NO-1526 Moss 7 Dearborn Road TEL )1/203 47 78 D-47058 Duisburg P.O.Box 2178,NO-1521 Moss Peabody,MA 01960 FAX:+43(0 e-mail:info)1/203 47 TEL.:+49(0)203-301-0 TEL.:+47(0)69-264860 TEL.:+1-978 535-6060 FAX:+49(0)203-301-10 389 FAX:+47(0)69-267333 FAX:+1-978 535-1720 Belgium e-mail:krohne@krohne.de e-mail:postmaster@krohne.no e-mail: info@krohne.com KROHNE Belgium N.V. Internet:www.krohne.no Brusselsoaat 320 India B-1702 Groot Bijgaarden KROHNE Marshall Ltd. Singapore Overseas Representatives TEL.:+32(0)2-4 66 00 10 A-34/35,M.I.D.C. Tokyo Keiso-KROHNE Singapore Pte.Ltd. FAX:+32(0)2-4 66 08 00 Industrial Area,H-Block, 14,International Business Park, Algeria Kuwait e-mail:krohne@krohne.be Pimpri Poona 411018 Jurong East Argentina Libya TEL.:+91(0)202-7442020 Chiyoda Building#01-01/02 Belarus Lithuania Braid FAX:+91(0)202-7442020 Singapore 609922 KROHNE Conaut e-mail:pcu@vsnl.net Singapore Cameroon Malaysia Controles Automaticos Ltda. TEL„++65-65-67-4548 Canada Morocco Estrada Das Aguas Espraiadas,230 C.P.56 Iran FAX:++65-65-67-9874 Chile Mauritius 06835-080 EMBU-SP KROHNE Liaison Office Colombia Mexico TEL.:+55(0)11-4785-2700 North Sohrevardi Ave. South Africa Croatia New Zealand Denmark Peru FAX:+55(0)11-4785-2768 26,Sarmad St.,Apt.#9 KROHNE Pry.Ltd. Ecuador Poland e-mail:conaut@conaut.com.br Tehran 15539 163 New Road Egypt China TEL.:++98-21-874-5973 Halfway House Ext.13 Finland Romania KROHNE Measurement Instruments FAX:++98-21-850-1268 Midrand Gabon Saudi Arabia (Shanghai)Co.Ltd.,(KMIC) e-mail:krohne@krohneimn.com TEL.:+27(0)11-315-2685 Ghana Senegal 1 11 +27(0) -805-053 Room 1501,Tower A Italy FAX: Greece Slovakia City Centre of Shanghai Hong Kong Slovenia 100 Zun Yi Road KROHNE Italia Srl. e-mail:midrand@krohne.co.za Hungary Sweden Via V.Monti 75 Shanghai 200051 Spain Indonesia Taiwan I-20145 Milano I.I.KROHNE Iberia,S.r.L. TEL.:+86 216237 2770 Ivory Coast Thailand FAX:+86 216237 2771 Ca TEL.:+39(0)2-4 30 06 61 ligono Industrial Nilo Iran Turkey FAX:+39(0)2-43 00 66 66 Calls Brasil,n°.5 Cellphone:+86(0)139 01954185 e-mail:info@krohne.it Ireland Tunisia e-mail:info@krohne-asia.com E-28806 Alcala de Henares-Madrid Israel Venezuela TEL.:+34(0)91-8 83 2152 Japan Yugoslavia CIS Korea FAX:+34(0)91-8 83 48 54 Kanex KROHNE Engineering AG KROHNE Korea e-mail:krohne@krohne.es Jordan Business-Centre Planeta,Office 404 Room 508 Miwon Bldg ul.Marxistskaja 3 43 Yoido-Dong Switzerland 109147 Moscow/Russia Youngdeungpo-Ku KROHNE AG Other Countries: KR TEL.:+7(0)095-9117165 Seoul,Korea Uferstr.90 Gm HNE Messtechnik TEL.:00-822780-1743 bH&Co.KG -- FAX:+7(0)095-7428873 CH-4019 Basel e-mail:krohne@dol.ru FAX:00-82-2-780-1749 TEL.:+41(0)61-638 30 30 Ludwig-Krohne-Str. e-mail:krohnekorea@krohnekorea.com D-47058 Duisburg FAX:+41(0)61-638 30 40 Czech Republic e-mail:info@krohn TEL.:+49(0)203-301-0 KROHNE CZ,spot.s no. Netherlands FAX:+49(0)203-301 389 Sobssicka 156 KROHNE Altometer e-mail:export@krohne.de CZ-63800 Brno Kerkeplaat 12 TEL.:+420 545 532 111 NL-3313 LC Dordrecht FAX:+420 545 220 093 TEL.:+31(0)78-6306300 e-mail:brno@krohne.cz FAX:+31(0)78-6306390 Subject to change without notice e-mail:postmaster@krohne-altometer.nl