TD_OPTIPROBE__en__110117_4001208601_R01
�a A0965t�� M OPTIPROBE Technical Datasheet The low-cost flow indicator • Simple installation • Accurate and stable measurements • KROHNE quality ©KROHNE 01/2011-4001208601 -TD OPTIPROBE R01 en KROHNE CONTENTS 1 Product features 3 1.1 The low cost flow indicator...............................................................................................3 1.2 Measuring principle.......................................................................................................... 5 2 Technical data 6 2.1 Technical data................................................................................................................... 6 2.2 Dimensions.......................................................................................................................8 3 Installation 9 3.1 Notes on installation ........................................................................................................ 9 3.2 Installation conditions...................................................................................................... 9 3.2.1 Inlet and outlet........................................................................................................................9 3.2.2 Mounting position.................................................................................................................. 10 3.2.3 T-section ............................................................................................................................... 10 3.2.4 Vibration................................................................................................................................ 11 3.2.5 Magnetic field........................................................................................................................ 11 3.2.6 Bends .................................................................................................................................... 11 3.2.7 Open discharge ..................................................................................................................... 12 3.2.8 Control valve ......................................................................................................................... 12 3.2.9 Pump..................................................................................................................................... 13 3.2.10 Temperatures ..................................................................................................................... 13 4 Electrical connections 14 4.1 Safety instructions.......................................................................................................... 14 4.2 Connection diagram ....................................................................................................... 14 2 www.krohne.com 01/2011 -4001208601-TD OPTIPROBE R01 en I - - - E = PRODUCT FEATURES 1 .1 The low cost flow indicator The OPTIPROBE is a magnetic inductive flow indicator for use in conjunction with clean, electrically conductive fluids in pipes with nominal diameters of 80 mm and above. O o \ 1) e �a i A0�51 O J) Connection box (2) Process connection flange (a) Head with integrated coils and electrodes 01/2011-4001208601-TD OPTIPROBE R01 en www.krohne.com 3 p PRODUCT FEATURES --� _ Highlights • All wetted parts of non-corrosive materials • Easy to install • Pulsed DC field excitation • Wide (bidirectional) measuring range • Installation possible in pipelines under pressure Industries • Water • Wastewater Applications • For clean liquids with a minimum conductivity of 20 µS/cm 4 www.krohne.com 01/2011 -4001208601 -TD OPTIPROBE R01 en PRODUCT FEATURES 0 1 .2 Measuring principle The OPTIPROBE is inserted through a hole drilled in the pipe. A magnetic coil located in the probe's measuring head generates a pulsed DC field perpendicular to the measuring head. This togetherwith the movement of the fluid induces a voltage proportional to the mean flow velocity. The voltage is picked up by two electrodes fitted to the front of the probe and forwarded to a signal converter, where it is converted into a measured flow speed. 01/2011 -4001208601-TD OPTIPROBE R01 en www.krohne.com 5 TECHNICAL DATA OPTIPROBE 2.1 Technical data • The following data is provided for general applications. lfyou require data that is more relevant to your specific application,please contact us oryour local representative. • Additional information(certificates, special tools, software,...]and complete product documentation can be downloaded free of charge from the website(Download Center]. Measuring system Measuring principle Faraday's law Application range Electrically conductive fluids Measured value Flow velocity Design Features Wide range of measuring range Bidirectional measuring Non-corrosive materials Two models available Models Model A: insertion length 25 mm Model B: insertion length 25...400 mm (variable, replaceable under operating pressure) Compact version With IFC 100 or IFC 300 signal converter IFC 300 only in GKl mode Remote version With IFC 100 or IFC 300 signal converter IFC 300 only in GKl mode Nominal diameters >_DN80 Measurement range -12...12 m/s Measuring accuracy Reference conditions Medium:water Electrical conductivity:>_300 µS/cm Temperature: 10...30°C Accuracy Full scale range >3 m/s:3%of measured value Full scale range<_3 m/s:2%of measured value+2 cm/s Repeatability 2%of measured value 6 www.krohne.com 01/2011-4001208601-TD OPTIPROBE R01 en - � TECHNICAL DATA Operating conditions Temperature Process temperature 0...100°C Ambient temperature -30...55°C Pressure Connecting flange DN40, PN 16 Chemical properties Physical condition Electrically conductive liquids Electrical conductivity >_20 µS/cm Installation conditions Installation Pipe must be fully filled for model A. Electrodes must be perpendicular to the flow direction Weld the socket with connecting flange square to the longitudinal axis of the pipeline Probe insertion length minimum 25 mm Flow direction Forward and reverse Arrow on connection box indicates the positive flow direction Inlet run >10 DN Outlet run >5 DN Materials Measuring head POM (Polyacetal) Measuring head sleeve CrNi steel 1.4301 Electrodes Hastelloy C Connecting flange Steel RST 37 Counterflange Steel RST 37 Pipe sleeve Steel RST 37 Flange gasket FKM, FPM Junction box Die cast aluminum, polyurethane coated Electrical connections Signal cable,type A(DS) Standard cable, double shielded. Maximum length:300 m Field current cable Minimum cross section of 2x 1.5 mm2 Maximum length:300 m No part of delivery 01/2011-4001208601-TD OPTIPROBE R01 en www.krohne.com 7 TECHNICAL DATA OPTIPROBE 2.2 Dimensions Model Approximate dimensions if (1):Model A a=215mm/8.5" b=78mm/3.1" (2):Model B c=877 mm/34.5" c a b m O $ www.krohne.com 01/2011-4001208601-TD OPTIPROBE R01 en M INSTALLATION p 3.1 Notes on installation Inspect the cartons carefully for damage or signs of rough handling. Report damage to the carrier and to the local office of the manufacturer. Check the packing list to check if you received completely all that you ordered. Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. 3.2 Installation conditions 3.2.1 Inlet and outlet O O Figure 3-1:Recommended inlet and outlet sections (1) >_10 DN >_5DN 01/2011 -4001208601-TD OPTIPROBE R01 en www.krohne.com 9 p INSTALLATION 3.2.2 Mounting position 1771 03 40 s0 O O O — Figure 3-2:Mounting position 1� Flow profile must be fully developped. 22) Welding instructions:the electrodes must point to the side of the pipeline! 3Z Insert the OPTIPROBE perpendicular. 4� Insertion length>_25mm. 5� DN>_80mm. The OPTIPROBEis a sensor which measures flow speed atone point in the pipe. In case the flow speed has to be converted into a volume,please note that the measured value depends on the used diameter and the insertion length, because the OPTIPROBE decreases the inner surface of the pipe at the measuring section. The corrected GKl value for any other installation condition can be calculated as: 30 * insertion GKl = GKIcaL * (1 - 2 0.79 * DN All measures in mm GKI,,,is GKl on nameplate 3.2.3 T-section i t0 Figure 3-3:Distance after T-sections 1� >_30 DN 10 www.krohne.com 01/2011 -4001208601 -TD OPTIPROBE R01 en INSTALLATION 3.2.4 Vibration Figure 3-4:Avoid vibrations 3.2.5 Magnetic field Figure 3-5:Avoid magnetic fields 3.2.6 Bends Figure 3-6:Installation in bending pipes 01/2011-4001208601-TD OPTIPROBE R01 en www.krohne.com 11 p INSTALLATION Figure 3-7:Installation in bending pipes 3.2.7 Open discharge Figure 3-8:Installation before an open discharge 3.2.8 Control valve J Figure 3-9:Installation before control valve 12 www.krohne.com 01/2011-4001208601-TD OPTIPROBE R01 en INSTALLATION 3.2.9 Pump Figure 3-10:Installation after pump 3.2.10 Temperatures 02 10 1Q Process temperature © Ambient temperature Protect the device from direct sunlight. Temperature range [°C] [OF] X. min. ax. Process temperature 0 100 32 212 Ambient temperature -30 55 -22 131 01/2011-4001208601-TD OPTIPROBE R01 en www.krohne.com 13 0 ELECTRICAL CONNECTIONS --I _ 4.1 Safety instructions All work on the electrical connections may only be carried out with the power disconnected. Take note of the voltage data on the nameplate! Observe the national regulations for electrical installations! For devices used in hazardous areas, additional safety notes apply,please refer to the Ex documentation. Observe without fail the local occupational health and safety regulations.Any work done on the electrical components of the measuring device may only be carried out by properly trained specialists. Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. 4.2 Connection diagram • The outer shield of the signal cable in the signal converter housing is connected via the strain relief terminal. • Bending radius of signal and field current cable: >_ 50 mm/2". • The following illustration is schematic. The positions of the electrical connection terminals may vary depending on the type of converter. 14 www.krohne.com 01/2011 -4001208601 -TD OPTIPROBE R01 en ELECTRICAL CONNECTIONS 0 4 �40�3O� 3 2 20 1 9 8 7 10 (10) (60) O O O 02 03 <= O 40 L3L2 1 Figure 4-1:Connection diagram 1Q Electrical terminal compartment in housing of the signal converter for signal and field current cable. © Signal cable (3 Field current cable C 4Q Connection box for measuring sensor © Functional ground FE 01/2011-4001208601-TD OPTIPROBE R01 en www.krohne.com 15 t; �t KROHNE product overview • Electromagnetic flowmeters • Variable area flowmeters • Ultrasonic flowmeters v • Mass flowmeters • Vortex flowmeters • Flow controllers L 3 • Level meters v m C r • Temperature meters 0 v • Pressure meters • Analysis products • Measuring systems for the oil and gas industry 0 w • Measuring systems for sea-going tankers 0 a o 0 0 Head Office KROHNE Messtechnik GmbH N Ludwig-Krohne-Str. 5 D-47058 Duisburg (Germany) 0 Tel.:+49 (0)203 301 0 0 Fax:+49 (0)203 301 10389 Z infofdkrohne.de & The current list of all KROHNE contacts and addresses can be found at: KRDHNE Y o www.krohne.com