Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
TD_WATERFLUX 3070__en__100427_4000663102_R02
1 1 1 KROHNE M WATERFLUX 3070 • Engineered and manufactured for the water and wastewater industry • Highly accurate measurement without in- and outlet lengths • Battery operated, stand alone water meter, battery life up to 15 years ©KROHNE 04/2010-4000663102-TD WATERFLUX 3070 R02 en KROHNE CONTENTS WATERFLUX 1 Product features 3 1.1 The power of independence ............................................................................................. 3 1.2 Options.............................................................................................................................. 5 1.3 Measuring principle.......................................................................................................... 6 2 Technical data 7 2.1 Technical data................................................................................................................... 7 2.2 Pressure loss.................................................................................................................. 13 2.3 Measuring accuracy ....................................................................................................... 14 2.4 Custody transfer............................................................................................................. 15 2.4.1 01 M L R49............................................................................................................................... 15 2.4.2 MI-001 ................................................................................................................................... 18 2.5 Dimensions and weights ................................................................................................ 20 3 Installation 22 3.1 Notes on installation ...................................................................................................... 22 3.2 Inlet and outlet ............................................................................................................... 22 3.3 Mounting position and flange deviation ......................................................................... 23 3.4 T-section......................................................................................................................... 23 3.5 Vibration.......................................................................................................................... 24 3.6 Magnetic field ................................................................................................................. 24 3.7 Open discharge............................................................................................................... 24 3.8 Bends.............................................................................................................................. 25 3.9 Control valve................................................................................................................... 25 3.10 Airventing..................................................................................................................... 26 3.11 Pump............................................................................................................................. 26 3.12 IP 68 mounting.............................................................................................................. 27 4 Electrical connections 28 4.1 Safety instructions.......................................................................................................... 28 4.2 Installation of converter................................................................................................. 28 4.3 Grounding ....................................................................................................................... 28 4.4 Connection of signal cable ............................................................................................. 28 4.5 Terminal assignment of converter................................................................................. 31 2 www.krohne.com 04/2010-4000663102-TD WATERFLUX 3070 R02 en WATERFLUX 3070 PRODUCT FEATURES 0 1 .1 The power of independence The WATERFLUX 3070 is a battery powered electromagnetic water meter for standard applications in the water and wastewater industry. It has a very long battery life of up to 15 years, making it especially suitable for applications where no power connection is available. The WATERFLUX 3070 has been designed for custody transfer applications. It meets the requirements of the OIML R49 and can be verified according to MI-001 for DN25...300. The strength of the WATERFLUX lies in its unique flow sensor construction with a rectangular cross section. The coils are arranged so that a strong, homogeneous magnetic field is formed leading to an improved signal to noise ratio. The measurement is therefore independent of the flow profile and measurements are very stable.This results in a very good low flow performance and allows for no in- and outlet sections. t0 OO OO 1� Unique flow sensor design with rectangular cross-section 2� Highly resistant Rilsan®coating 3� Built-in reference electrode 04/2010-4000663102-TD WATERFLUX 3070 R02 en www.krohne.com 3 p PRODUCT FEATURES WATERFLUX Highlights • Low inaccuracy of±0.2% of measuring value + 0.5 mm/s • Suitable for custody transfer according to OIML R49 and MI-001 • Excellent performance in low flow conditions • Bi-directional measurement • No in- and outlet conditions (0 DN and 0 DN) • Low energy consumption and self providing energy by internal batteries for up to 15 years • Rilsan®polymer coating. • Buriable sensor (IP 68), installation in chambers is not necessary • Maintenance free operation, no moving parts, no wear and obstruction free • Optional battery powered data Logger/GSM module for remote data transfer • Very attractive cost of ownership • No grounding rings due to integrated reference electrode Industries • Dewatering • District metering • Irrigation • Revenue metering • Water abstraction Applications • Measurement of raw water, potable water, irrigation water • Well chambers • Monitoring of distribution networks • Pipeline leak detection • Measuring of water consumption 4 www.krohne.com 04/2010-4000663102-TD WATERFLUX 3070 R02 en PRODUCT FEATURES 0 1 .2 Options ,��• Remote version r� The WATERFLUX is also available in a remote field version with buriable IP 68 sensor as WATERFLUX 3070 F. 1 WATERFLUX as flowmeter opWhere mains power is available, the WATERFLUX sensor can be combined with the economical IFC 100 signal converter or the fully featured IFC 300 signal converter. GSM and data logger module: KGA 42 There is an increased demand by water utilities for remote reading of water meters. They are often installed at remote locations in the drinking water distribution networks or sites difficult to reach such as metering manholes below the ground. For all these applications the KROHNE KGA 42 data Logger and GSM module offers an efficient wireless communication solution for the transmission of data. It fulfils most customer requirements as it is easy to install, waterproof (IP 68), has a built-in dedicated antenna and operates on batteries. Connected with WATERFLUX 3070, KGA 42 sends out SMS reports on a daily basis or direct SMS alerts to maintenance personnel. 04/2010-4000663102-TD WATERFLUX 3070 R02 en www.krohne.com 5 H PRODUCT FEATURES WATERFLUX 1 .3 Measuring principle An electrically conductive fluid flows inside an electrically insulating pipe through a magnetic field. This magnetic field is generated by a current, flowing through a pair of field coils. Inside of the fluid, a voltage U is generated: U =v* k* B * D in which: v= mean flow velocity k= factor correcting for geometry B = magnetic field strength D = inner diameter of flow meter The signal voltage U is picked off by electrodes and is proportional to the mean flow velocity v and thus the flow rate q.A signal converter is used to amplify the signal voltage, filter it and convert it into signals for totalising, recording and output processing. DN25...300 3 2 4 1 1� Induced voltage(proportional to flow velocity) 2� Electrodes 3� Magnetic field 4� Field coils DN350...600 2 I 4 1 1� Induced voltage(proportional to flow velocity) 22) Electrodes 3� Magnetic field 4� Field coils 6 www.krohne.com 04/2010-4000663102-TD WATERFLUX 3070 R02 en WATERFLUX 3070 TECHNICAL DATA 2.1 Technical data • The following data is provided for general applications. lfyou require data that is more relevant to yourspecific application,please contact us oryour local representative. • Additional information(certificates, special tools, software,...)and complete product documentation can be downloaded free of charge from the website(Download Center). Measuring system Measuring principle Faraday's law Application range Electrically conductive fluids Measured value Primary measured value Flow velocity Secondary measured value Volume flow Design Features Unique rectangular flow tube design providing improved flow profile and signal to noise ratio resulting in highest accuracy, low energy consumption and large turndown ratio Rilsan polymer coated flow tube without internal or moving parts Built-in reference electrode with floating potential design Self providing energy by batteries for up to 15 years Modular construction The measurement system consists of a flow sensor and a signal converter. It is available as compact and as separate version. Compact version WATERFLUX 3070 C Remote version In field (F) mount version:WATERFLUX 3070 F Cable length up to 25 m/75 ft Nominal diameter DN25...600/1...24" Measurement range -12...12 m/s/-40...40 ft/s Starting flow from 0 m/s/0 ft/s onwards User interface Display 8 digits LCD Display of positive and negative counter,sum counter,flow rate Status indication for battery,flow/counter direction,empty pipe Units Volume in m3, US Gallons Flow rate in m3/h, USGPM, Vs Cable connnections Standard:2x M20x1.5 Optional:'/2" NPT, PF'/2 04/2010-4000663102-TD WATERFLUX 3070 R02 en www.krohne.com 7 TECHNICAL DATA Measuring accuracy Reference conditions Flow conditions:similar to EN 29104 Medium:water Temperature: 20°C/68°F Operating pressure: 1 bar/14.5 psig Maximum measuring error MV= Measured value DN25...300:±0.2%of MV±0.5 mm/s/0.02 inch/s DN350...600:±0.2%of MV±1.5 mm/s/0.06 inch/s Optional:verification to MI-001 for DN25...300 For detailed information on the measuring accuracy,see chapter "Measuring accuracy". Repeatability DN25...300:±0.1% DN350...600:±0.2% Operating conditions Temperature Process temperature Rilsan liner: -5...+70°C/+23...+158°F Hard rubber liner: -5...+80°C/+23...+176°F Ambient temperature -40...+65°C/-40...+149°F Storage temperature -50...+70°C/-58...+158°F Pressure Ambient pressure Atmospheric Nominal flange pressure up to PN 16 EN 1092-1 DN200...600: PN 10 DN25...200: PN 16 ISO installation length Standard DN50...200/ASME 2...8" DN300/ASME 12" DN400...600/ASME 16...24" Optional DN25...40/ASME 1...1'h" DN250/ASME 10" DN350/ASME 14" ASME B16.5 150 lbs RF Chemical properties Physical condition Clean water Electrical conductivity >_20 µS/cm Process conditions Raw water,ground-and surface water Potable water Irrigation water 8 www.krohne.com 04/2010-4000663102-TD WATERFLUX 3070 R02 en TECHNICAL DATA Installation conditions Installation Take care that flow sensor is always fully filled For detailed information see chapter"Installation" Flow direction Forward and reverse. Arrow on flow sensor indicates positive flow direction. Inlet run DN25...300:>_0 DN DN350...600:>_5 DN See chapter"Measuring accuracy' Outlet run DN25...300:>_0 DN DN350...600:>_2 DN See chapter"Measuring accuracy" Dimensions and weights For detailed information see chapter"Dimensions and weights". Materials Sensor housing Sheet steel, polyurethane coated Option for DN350...600:Stainless steel Measuring tube DN25...200: Metallic alloy DN250...600:Stainless steel Flanges Standard:steel 1.0460/1.0038(RSt37-2) Option for DN350...600:Stainless steel Liner DN25...300: Rilsan@ DN350...600: Hard rubber Connection box Standard: Die-cast aluminium, polyurethane coated (remote versions only) Option:Stainless steel Measuring electrodes DN25...200:Stainless steel 1.4301 /AISI 304 DN250...600: Hastelloy C22 Grounding electrode Stainless steel 1.4301 /AISI 304(only for DN25...200) Other materials on request Grounding rings DN25...300: not required Optional for DN350...600:Stainless steel rings Other materials on request Signal converter housing Die-cast aluminium, polyurethane coated 04/2010-4000663102-TD WATERFLUX 3070 R02 en www.krohne.com 9 TECHNICAL DATA Process connections EN 1092-1 DN25...600 in PN 10...16 ASME 1...24" in 150 lbs JIS DN350...600 in JIS 10 K/20 K Others Threaded connections on request For information on available combinations of nominal flange pressure and nominal diameter see chapter"Dimensions and weights". Electrical connections Power supply Battery Standard: 1 Lithium battery(D-cell) Option 1:2 Lithium batteries(D-cell) Option 2:external battery pack with 4 lithium batteries(D-cell, IP 68) Typical lifetime See graph at the end of this table. Alarm Pre-alarm at 10%of energy left Final alarm at 1%of energy left Battery replacement Possible without loss of totalizer data In-and output Outputs 2 Passive pulse outputs for remote totalising: f<_500 Hz; I<_ 10 mA; U:2.7...24 VDC (P<_ 100 mW) 2 Passive status outputs: I<_ 10 mA; U: 2.7...24 VDC (P<_ 100 mW) Communication Optional:external data Logger/GSM module,SMS protocol to: SCADA system (at customer's site) OPC server(to be connected to customer's OPC client) PCWin (mini-SCADA can be supplied by KROHNE) 10 www.krohne.com 04/2010-4000663102-TD WATERFLUX 3070 R02 en TECHNICAL DATA Approvals and certificates CE This device fulfills the statutory requirements of the EC directives. The manufacturer certifies successful testing of the product by applying the CE mark. Electromagnetic compatibility Directive:2004/108/EC Harmonized standard: EN 61326-1:2006 Low voltage directive Directive: 2006/95/EC Harmonized standard: EN 61010: 2001 Pressure equipment directive Directive:97/23/EC Category I, II or SEP Fluid group 1 Production module H Other approvals and standards Custody transfer Standard:without verification MI-001 type examination certificate for DN25...300 OIML R49 certficate of conformity for DN25...300 Conform EN 14154/ISO 4064 Drinking water approvals DN25...300:ACS DVGW, KTW(NSF,WRc pending) DN350...600:ACS, DVGW, NSF(KTW,WRc pending) Protection category acc.to Standard IEC 529/EN 60529 IP 66/67(NEMA 4/4X/61 Optional(F version sensor only) IP 68 field (NEMA 6P) IP 68 factory(NEMA 6P) IP 68 is only available with a stainless steel connection box. Permanent submersible (with stainless steel connection box) Permanent burial(with burial coating and stainless steel connection box) Shock test IEC 68-2-27 Vibration test IEC 68-2-34 04/2010-4000663102-TD WATERFLUX 3070 R02 en www.krohne.com 11 TECHNICAL DATA Typical lifetime of batteries fat 25T) for a DN80 Y 30 25 20 15 10 5-—�/� 0 5 10 15 20 25 X Figure 2-1:X=Sampling interval in seconds,Y=typical lifetime in years 1� dual battery pack ® single battery 12 www.krohne.com 04/2010-4000663102-TD WATERFLUX 3070 R02 en TECHNICAL DATA 2.2 Pressure loss [mbar] 1 3 4 500 6 1 10 100 1000 [m3/hl Figure 2-2:Pressure loss between 1 m/s and 9 m/s for DN25...100 1Q DN25 © DN40 Q3 DN50 4� DN65 Q5 DN80 © DN100 [mbar] 500 Av 10 100 1000 10000 [m3/hl Figure 2-3:Pressure loss between 1 m/s and 9 m/s for DN125...300 1Q DN125 © DN150 Q3 DN200 4Q DN250 © DN300 Diameters DN350...600 have a neglectible pressure loss. 04/2010-4000663102-TD WATERFLUX 3070 R02 en www.krohne.com 13 TECHNICAL DATA 2.3 Measuring accuracy Accuracy and reproducibility are important characteristics of a watermeter. Each single watermeter is standard wet calibrated by direct volume comparison at KROHNE's certified calibration facilities before leaving the factory. The performance of the watermeter is defined and documented in an individual watermeter calibration certificate. Y N 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1 2 3 4 5 6 7 8 9 10 11 12 X[m/sl Figure 2-4:X= flow velocity[m/sl;Y=deviation N 1Q DN25...300:If the inlet or outlet section is>_than respectively 3 DN/1 DN © DN350...600:If the inlet or outlet section is>_than respectively 5 DN/2 DN �3 DN25...300:If the inlet or outlet section is respectively 0 DN/0 DN 14 www.krohne.com 04/2010-4000663102-TD WATERFLUX 3070 R02 en WATERFLUX 3070 TECHNICAL DATA p 2.4 Custody transfer The WATERFLUX complies with the international recommendation OIML R49 and the European directive MI-001. Limtations for custody transfer applications: • Process temperature: +0.1...+50°C/32.2...122°F • Ambient temperature: -10...+55°C/ 14...131°F • Process temperature: up to 10 bar • straight in-/outlet length: 3 DN / 1 DN • Sealing: as per legal requirements • Calibration: at R = 80 2.4.1 01 M L R49 The OIML R49 recommendation (2006) concerns water meters intended for the metering of cold potable water and hot water. WATERFLUX 3070 has a certificate of compliance with OIML R49, issued by NMi. The OIML R49 recommendation sets out the conditions to which water meters shall comply to meet the requirements of the services of legal metrology in countries where these instruments are subject to state controls. The measuring range of the water meter is determined by Q3 (nominal flow rate) and "R" (ratio). The WATERFLUX 3070 meets the requirements for water meters of accuracy class 1 and 2. For accuracy class 1, the maximum permissible error for water meters is±1%for the upper flow rate zone and ±3% for the lower flow rate zones. For accuracy class 2, the maximum permissible error for water meters is±2%for the upper flow rate zone and ±5% for the lower flow rate zones. Y 0 X 0 O OIML 01 Q2 Q3 Q4 ISO Qmin Qt On Qmax Figure 2-5:ISO flow rates added to figure as comparison towards OIML X:Flow rate;Y:Maximum measuring error l%1 11) ±3%for class 1,±5%for class 2 devices 2� ±1%for class 1,±2%for class 2 devices 04/2010-4000663102-TD WATERFLUX 3070 R02 en www.krohne.com 15 TECHNICAL DATA Q1 = Q3/R Q2 = Q1 * 1.6 Q3 = Q1 * R Q4= Q3 * 1.25 16 www.krohne.com 04/2010-4000663102-TD WATERFLUX 3070 R02 en TECHNICAL DATA OIML R49 Class 1 DN Span (R) Flow rate [m3/h] Minimum Transitional Permanent Overload Q1 Q2 Q3 Q4 65 250 0.400 0.640 100 125.0 80 160 0.625 1.000 100 125.0 80 250 0.640 1.024 160 200.0 100 160 1.000 1.600 160 200.0 100 250 1.000 1.600 250 312.5 125 160 1.563 2.500 250 312.5 125 250 1.600 2.560 400 500.0 150 160 2.500 4.000 400 500.0 150 250 2.520 4.032 630 787.5 200 160 3.938 6.300 630 787.5 200 200 4.000 6.400 800 1000.0 250 160 6.250 10.000 1000 1250.0 300 160 10.000 16.000 1600 2000.0 OIML R49 Class 2 DN Span (R) Flow rate [m3/hl Minimum Transitional Permanent Overload Q1 Q2 Q3 Q4 25 400 0.025 0.040 10 12.5 25 400 0.040 0.064 16 20.0 40 400 0.063 0.100 25 31.3 40 400 0.100 0.160 40 50.0 50 400 0.100 0.160 40 50.0 50 400 0.160 0.252 63 78.8 65 400 0.160 0.252 63 78.8 65 400 0.250 0.400 100 125.0 80 400 0.250 0.400 100 125.0 80 400 0.400 0.640 160 200.0 100 400 0.400 0.640 160 200.0 100 400 0.625 1.000 250 312.5 125 400 0.625 1.000 250 312.5 125 400 1.000 1.600 400 500.0 150 400 1.000 1.600 400 500.0 150 400 1.575 2.250 630 787.5 200 315 2.000 3.200 630 787.5 200 400 2.000 3.200 800 1000.0 250 400 2.500 4.000 1000 1250.0 300 400 4.000 6.400 1600 2000.0 04/2010-4000663102-TD WATERFLUX 3070 R02 en www.krohne.com 17 p TECHNICAL DATA - E 2.4.2 MI-001 All new designs of water meters that are to be used for legal purposes in Europe require certification under the Measuring Instruments Directive (MID) 2004/22/EC.Annex MI-001 of the MID applies to: water meters intended for the measurement of volume of clean, cold or heated water in residential, commercial and light industrial use.A Type examination certificate to the MID certificate is valid in all the countries of the European Union. WATERFLUX 3070 has a type examination certificate to the MID MI-001 for DN25...300. The EC type examination certificate for WATERFLUX 3070 is valid for the compact and the remote version and applies for forward and reverse flow. According to MI-001 the maximum permissible error on volumes delivered between 02 (transitional) flow rate and Q4 (overload) flow rate is±2%. The maximum permissible error on volumes delivered between 01 (minimum) flow rate and Q2 (transitional) flow rate is±5%. Y 5% -----' 2% X -2% -5% ---- MID Q1 Q2 03 Q4 ISO Qmin Qt Qn Qmax Figure 2-6:ISO flow rates added to figure as comparison towards MID X:Flow rate;Y:Maximum measuring error N 18 www.krohne.com 04/2010-4000663102-TD WATERFLUX 3070 R02 en TECHNICAL DATA MI-001 DN Span (R) Flow rate [m3/h] Minimum Transitional Permanent Overload Q1 Q2 Q3 Q4 25 400 0.025 0.040 10 12.5 25 400 0.040 0.064 16 20.0 40 400 0.063 0.100 25 31.3 40 400 0.100 0.160 40 50.0 50 400 0.100 0.160 40 50.0 50 400 0.158 0.252 63 78.8 65 400 0.158 0.252 63 78.8 65 400 0.250 0.400 100 125.0 80 400 0.250 0.400 100 125.0 80 400 0.400 0.640 160 200.0 100 400 0.400 0.640 160 200.0 100 400 0.625 1.000 250 312.5 125 400 0.625 1.000 250 312.5 125 400 1.000 1.600 400 500.0 150 400 1.000 1.600 400 500.0 150 400 1.575 2.520 630 787.5 200 315 2.000 3.200 630 787.5 200 400 2.000 3.200 800 1000.0 250 400 2.500 4.000 1000 1250.0 300 400 4.000 6.400 1600 2000.0 04/2010-4000663102-TD WATERFLUX 3070 R02 en www.krohne.com 19 TECHNICAL DATA 2.5 Dimensions and weights Compact version b a= 170mm/6.7" b= 132mm/5.2" a c= 140mm/5.5" Total height=H +a � H -- ---- - -01 -- 0 0 L o o W Remote version,sensor b c a=77mm/3.1" b= 139mm/5.5" - - a c= 106mm/4.2" N o Total height=H +a H - ---- ---- - - L W Remote version,signal converter b c b= 132mm/5.2" c=235mm/9.3" oo H=310mm/12.2" oo Joo H Weight=3.3 kg/7.3" 0 0 20 www.krohne.com 04/2010-4000663102-TD WATERFLUX 3070 R02 en TECHNICAL DATA Dimensions and weights [metric] EN 1092-1 Dimensions [mm] Approx. weight [kg] DN PN L H W 25 16 150 150.5 115 5 40 16 150 165.5 150 5.7 50 16 200 165 13 65 16 200 200 185 11 80 IRWP 16 200 209 200 17 100 16 250 237 220 17 125 16 250 266 250 21 150 16 300 300 285 29 200 10/16 350 361 340 36 250 10 400 408 395 50 300 10 500 458 445 60 350 10 500 510 505 80 400 10 600 568 565 103 450 10 600 618 615 113 500 10 600 671 670 132 600 10 600 781 780 167 Dimensions and weights [imperial] ASME B16.5 (150 lb) Dimensions [inches] Approx. weight [lb] DN PN L H W 1 150 5.91 5.83 4.33 18 1'/2 150 5.91 6 4.92 21 2 150 7.87 7.05 5.98 34 3 150 7.87 8.03 7.50 42 4 150 9.84 9.49 9.00 56 5 150 9.84 10.55 10.00 65 6 150 11.81 11.69 11.00 80 8 150 13.78 14.25 13.50 100 10 150 15.75 16.30 16.00 148 12 150 19.69 18.78 19.00 212 14 150 27.56 20.67 21.00 289 16 150 31.50 22.95 23.50 369 18 150 31.50 24.72 25.00 415 20 150 31.50 26.97 27.50 497 24 150 31.50 31.38 32.00 680 04/2010-4000663102-TD WATERFLUX 3070 R02 en www.krohne.com 21 p INSTALLATION 3.1 Notes on installation Inspect the cartons carefully for damage or signs of rough handling. Report damage to the carrier and to the local office of the manufacturer. Check the packing list to check if you received completely all that you ordered. Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. 3.2 Inlet and outlet DN25...300 Figure 3-1:Authorised inlet and outlet Inlet/outlet:>_0 ON DN350...600 10 (2 Figure 3-2:Recommended inlet and outlet 1� Inlet:>_5 DN 22) Outlet:>_2 DN 22 www.krohne.com 04/2010-4000663102-TD WATERFLUX 3070 R02 en INSTALLATION p 3.3 Mounting position and flange deviation ,XQ . . - 0 - ------------- - - ---- - -- Figure 3-3:Mounting position and flange deviation Amax L-min • Mount sensor either with converter aligned upwards or downwards. • Install sensor in line with the pipe axis. • Pipe flange faces must be parallel to each other. Max.permissible deviation ofpipe flange faces:Lmax-Lmm <0.5mm 3.4 T-section 0 Figure 3-4:Distance after T-sections DN25...300:>_3 DN DN350...600:>_10 DN 04/2010-4000663102-TD WATERFLUX 3070 R02 en www.krohne.com 23 INSTALLATION 3.5 Vibration Figure 3-5:Avoid vibrations 3.6 Magnetic field Figure 3-6:Avoid magnetic fields 3.7 Open discharge //I1\ Figure 3-7:Installation before an open discharge 24 www.krohne.com 04/2010-4000663102-TD WATERFLUX 3070 R02 en INSTALLATION 3.8 Bends *Ar Figure 3-8:Installation in bending pipes Figure 3-9:Installation in bending pipes 3.9 Control valve Figure 3-10:Installation before control valve 04/2010-4000663102-TD WATERFLUX 3070 R02 en www.krohne.com 25 INSTALLATION 3.10 Air venting 0 Figure 3-11:Air venting 1Q >_5m © Air ventilation point 3.11 Pump Figure 3-12:Installation after pump 26 www.krohne.com 04/2010-4000663102-TD WATERFLUX 3070 R02 en ■ INSTALLATION 3.12 IP 68 mounting IP 68 versions are only available as remote version (F housing). You can put the sensor either into earth (buriable, with extra coating) or under water (submergible, stainless steel connection box). 10 Figure 3-13:IP 68 versions 1� Submergible 2� Buried 04/2010-4000663102-TD WATERFLUX 3070 R02 en www.krohne.com 27 0 ELECTRICAL CONNECTIONS WATERFLUX 4.1 Safety instructions Observe without fail the local occupational health and safety regulations.Any work done on the electrical components of the measuring device may only be carried out by properly trained specialists. Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. 4.2 Installation of converter Only applicable for remote versions. • Mount converter with mounting plate on wall or standpipe. • Keep distance between sensor and signal converter as short as possible. • Observe length of the delivered signal cable. 4.3 Grounding Figure 4-1:Grounding • DN25..300.the flow sensor is equipped with a reference electrode. Grounding is not necessary! • DN350...600:applygrounding rings if required. 4.4 Connection of signal cable The signal cable is only used with remote versions. The standard KROHNE WSC-cable includes both electrode and field current leads. 28 www.krohne.com 04/2010-4000663102-TD WATERFLUX 3070 R02 en ELECTRICAL CONNECTIONS p � 6 © 7 8 9 1 2 3 4 X1 X2 '00' Figure 4-2:Cable connection at sensor side,standard cable 1� cable length: 13 cm/5" © cable length:5 cm/2" Q3 brown+white cable,used for field current 4� purple and blue cable,used for electrode signals © cable length:8 cm/3" © Shield(terminal 1 of connector X2+U-clamp 04/2010-4000663102-TD WATERFLUX 3070 R02 en www.krohne.com 29 p ELECTRICAL CONNECTIONS 1� 6 © 78 g 1A233040 O X1 X2 O Figure 4-3:Cable connection at converter side,standard cable 1Q cable length: 13 cm/5" © cable length:5 cm/2" �3 brown+white cable,used for field current 4Q purple and blue cable,used for electrode signals Q5 cable length:8 cm/3" © Shield(terminal 1 of connector X2+U-clamp • Prepare appropriate cable lengths ( 10... 3Z) • Connect the shield to the U-clamp, the brown cable to terminal 7 and the white to terminal 8. • Connect the shield to terminal 1, the purple cable (white in case of type A or B cable) to terminal 2 and the blue (red in case of type A or B cable) to terminal 3. 30 www.krohne.com 04/2010-4000663102-To WATERFLUX 3070 R02 en ELECTRICAL CONNECTIONS p 4.5 Terminal assignment of converter +................................ m3/h 1 cm + -0.o-IL ' •• Figure 4-4:Removing side cap F�n -- Eel S oJ,- • o° 0 0 0 0 0 0 000 E01 o 0 0 Figure 4-5:Terminal assignment I) Status output 1 © Status output 2 03 Not connected 0 Ground Q Pulse output A © Pulse output B Electrical values • Pulse output passive: f<_ 500 Hz; I <_ 10 mA; U: 2.7...24 VDC (P<_ 100 mW) • Status output passive: I <_ 10 mA; U: 2.7...24 VDC (P<_ 100 mW) 04/2010-4000663102-TD WATERFLUX 3070 R02 en www.krohne.com 31 t; t - �t KROHNE product overview • Electromagnetic flowmeters • Variable area flowmeters v • Ultrasonic flowmeters • Mass flowmeters s • Vortex flowmeters 3 • Flow controllers v m • Level meters 0 v • Temperature meters • Pressure meters • Analysis products N O • Measuring systems for the oil and gas industry 0 X • Measuring systems for sea-going tankers J W W H Q H Head Office KROHNE Messtechnik GmbH Ludwig-Krohne-Str. 5 D-47058 Duisburg (Germany) 0 Tel.:+49 (0)203 301 0 0 Fax:+49 (0)203 301 10389 z infofdkrohne.de & The current list of all KROHNE contacts and addresses can be found at: KRDHNE Y o www.krohne.com