HomeMy WebLinkAboutRyder LC0549 - Waterline RelocationWATER MAIN LINE 12" D.I. WATER MAIN LINE RYDER SYSTEM, INC 11690 NW 105 STREET MIAMI, FLORIDA 33178 PHONE: (305) 500-5076 G-1 TITLE SHEET G-2 CIVIL SPECIFICATIONS 1 of 2 ALTA / ACSM SURVEY BY OTHERS 2 of 2 ALTA / ACSM SURVEY BY OTHERS SP-1 OVERALL SITE PLAN SP-2 DEMOLITION PLAN SP-2.1 DEMOLITION PLAN SP-3 UTILITY SITE PLAN SP-3.1 UTILITY SITE PLAN SP-4 GRADING PLAN CS-1 CIVIL SITE DETAILS DT-1 DETAILS DT-2 DETAILS PP-1 PLAN AND PROFILE DR A W I N G I N D E X RYDER TUKWILA LC0549 WATER LINE RELOCATION 17850 WEST VALLEY HWY TUKWILA, WA 98188 OWNER'S INTENDED USES TO CONSTRUCT OFFICES AND A FACILITY FOR THE RENTING, LEASING, MAINTENANCE, FUELING, SALES, WASHING, AND PARKING OF VEHICLES. PROJECT VARIABLES CIVIL ENGINEERING: INFINITY ENGINEERING GROUP LLC. CIVIL ENGINEERS PHONE: 813-434-4770 GEO-TECHNICAL REPORT: N/A GEO-TECHNICAL PHONE: N/A HEATING DEGREE DAYS: ---- SURVEYOR'S NAME: BBA LAND SURVEYING SURVEYORS TELEPHONE: 206-406-1257 SCOPE OF WORK NOTES (CONT) G-1 TI T L E S H E E T Re v . # Da t e D e s c r i p t i o n 17 8 5 0 W E S T V A L L E Y H W Y CI V I L U P G R A D E S TU K W I L A , W A 9 8 1 8 8 Jo b # : 22 5 - 5 3 . 0 0 Sc a l e : Da t e : Dr a w n B y : Ch e c k e d B y : 02 / 1 3 / 2 0 2 5 AS S H O W N INFINITY ENGINEERING GROUP, LLC 1208 East Kennedy Boulevard Suite 230 Tampa, Florida 33602 [p]: 813.434.4770[f]: 813.445.4211 www.iegroup.net Date RICHARD HERNANDEZ, P.E. WA REG. NO. 50841 JP NS RY D E R T U K W I L A L C - 0 5 4 9 Cert. of Auth. No. 603-536-314 COORDINATION NOTES WORK BY OTHERS: x ALL SIGNAGE WILL BE BY OTHERS, EXCEPT FOR POWER FEEDS. x FURNITURE WILL BE SUPPLIED AND INSTALLED BY OTHERS. BUILDING CODES SCOPE OF WORK NOTES 1. PERFORM ALL WORK IN ACCORDANCE WITH FEDERAL, STATE, ANDLOCAL CODES (INCLUDING - BUT NOT LIMITED TO - FIRE RESISTANCE RATED CONSTRUCTION & OPENING ASSEMBLIES, ACCESSIBILITYCOMPLIANCE, SMOKE DETECTION & THE LIKE) AS WELL AS WITHOWNER-FURNISHED CRITERIA, PLANS, AND SPECIFICATIONS; IF THERE ISA CONFLICT AMONG VARIOUS BID REFERENCES, PLANS,SPECIFICATIONS OR CODES, THE STRICTEST STANDARDS SHALL APPLYAND BE INCLUDED IN THE BID. 2. DESIGN/BUILD CONTRACTOR SHALL CONSTRUCT A NEW FACILITY ASINDICATED ON CRITERIA DRAWINGS, COMPLETE AND OPERATIONAL.COORDINATE FULLY WITH OTHER CONTRACTORS AT THE SITE. 3. SUCCESSFUL BIDDER SHALL UNDERTAKE TO PERFORM THE WORK ON ADESIGN/BUILD BASIS, AND IS RESPONSIBLE FOR ALL ENGINEERING, ARCHITECTURAL DESIGN, CONSTRUCTION DRAWINGS, PERMITS, ANDTESTING. 4. REVIEW ATTACHED BOUNDARY AND TOPOGRAPHICAL SURVEY. 5. DESIGN/BUILD CONTRACTOR SHALL VISIT THE SITE PRIOR TOSUBMITTING A PROPOSAL AND CHECK THE AREA OF WORK AND VERIFY LOCATIONS OF UTILITIES AND POINTS OF OF CONNECTION AND INCLUDEIN THE BID ALL REQUIRED, OFF-SITE INSTALLATIONS. 6.FOR PAVING DESIGN (AND BUILDING FOUNDATIONS), REVIEWGEOTECHNICAL REPORT. 7. DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH ALL STORM WATER PERMIT REQUIREMENTS REGULATING CONSTRUCTION SITE RUN OFF,AND EROSION AND SEDIMENT RUN OFF AND CONTROL AND SHALLINCLUDE IN HIS BASE BID ALL REQUIREMENTS FOR STORM WATERMANAGEMENT AND CONTROL, THAT IS, STRUCTURES, PIPES,HEADWALLS AND THE LIKE, AS INDICATED ON CIVIL/SITE DRAWINGS. 8. BIDS SHALL INCLUDE PAVING PER CIVIL/SITE DRAWINGS 9. NO METERS (THAT IS, WATER, GAS OR ELECTRICAL) OR TRANSFORMERSSHALL BE LOCATED ABOVEGROUND IN FRONT OF THE BUILDING. 10. THE WATER SERVICE PIPING SHALL BE EQUIPPED WITH A BACK FLOWPREVENTOR AND METER AS REQUIRED BY LOCAL CODES. PROVIDE FROST PROTECTION PER LOCAL CODE. 11. SIZE WATER SERVICE TO BUILDING TO PROVIDE MINIMUM OF 50 TO 70 PSIAT 50 GPM FOR WASH BAY EQUIPMENT. THE EXPOSED MAIN INTERNALWATER SUPPLY LINE IN THE MAIN SHOP AREA IS TO BE INSULATED.INSULATE BOTH DOMESTIC HOT WATER LINES AND STEAM LINES FROMWASH BAY HEATERS TO SERVICE BAY DROPS. 12. METAL BUILDING EAVE HEIGHT TO BE MINIMUM OF 20 FEET. MAINTAIN19'-0" CLEARANCE IN WORK BAYS TO OVERHEAD OBSTRUCTIONS (FOR EXAMPLE, PIPING CONDUITS - NOTE: LIGHT FIXTURES AND METALBUILDING FRAMES ALONG COLUMN LINES MAY EXTEND LOWER). 13.OVERHEAD DOORS (14' WIDE X 16' HIGH) SHALL BE HIGH LIFT TYPE WITHA MINIMUM CLEARANCE OF 18'-0" FROM FINISH FLOOR. PROVIDEINSULATED OVERHEAD DOORS WITH ELECTRIC OPERATOR & PHOTOELECTRIC SAFETY SENSORS FOR SERVICE BAYS AND WASH BAYIN THE BASE BID. 14.INSTALL ALL OWNER-FURNISHED EQUIPMENT LISTED IN THE ACCOMPANYING FACILITY EQUIPMENT CHECKLIST LIST. 15.DESIGN/BUILD CONTRACTOR SHALL INSTALL ALL OWNER-FURNISHED TANKS & EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'SRECOMMENDATIONS, PLANS, AND SPECIFICATIONS. PROVIDE ALLAPPURTENANCES REQUIRED BY CODE AND NOT PROVIDED BY OWNER FOR A COMPLETE OPERATIONAL SYSTEM. 16.DESIGN/BUILD CONTRACTOR SHALL INSTALL ALL OWNER-FURNISHEDTANKS & EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'SRECOMMENDATIONS, PLANS, AND SPECIFICATIONS. PROVIDE ALLAPPURTENANCES REQUIRED BY CODE AND NOT PROVIDED BY OWNER FOR A COMPLETE OPERATIONAL SYSTEM. 17.THE DESIGN/BUILD CONTRACTOR INSTALLING TANKS MUST BECERTIFIED BY TANK MANUFACTURER, PIPING MANUFACTURER AND LOCAL JURISDICTIONS (IF REQUIRED) AS TRAINED TO INSTALLMANUFACTURER'S TANK AND PIPING. 18.FIRE PROTECTION INCLUDE IN BASE BID. CODE REQUIREMENTS FORBUILDING FIRE PROTECTION MAY INCLUDE SPRINKLERS, SITE HYDRANT,EXTINGUISHERS, SMOKE ALARMS, FIRE ALARMS, FIRE WALLS, FIRE DOORS, EXIT LIGHTING, AND SIGNAGE. 19.ELECTRIC:MINIMUM ELECTRICAL SERVICE TO BE AS INDICATED ONELECTRICAL DRAWINGS. DESIGN/BUILD CONTRACTOR SHALL VERIFY ACTUAL ELECTRICAL LOADS AND PROVIDE ADJUSTED SERVICE ASREQUIRED. WORK TO BE PERFORMED IN ACCORDANCE WITH NATIONALELECTRICAL CODE AND COMPLY WITH ALL STATE AND LOCAL CODES. 20.DESIGN/BUILD CONTRACTOR SHALL INSTALL ELECTRICAL RACEWAYSINCLUDING SENSOR JUNCTION BOXES, AS WELL AS OTHER JUNCTIONBOXES AS REQUIRED, FOR A OWNER-FURNISHED AUTOMATIC TANK GAUGING (ATG), LEAK DETECTION AND MONITORING SYSTEM. 21. PRIOR TO RECEIVING APPROVAL OF FINAL PROGRESS PAYMENT, PUNCHLIST WORK MUST BE COMPLETED AND VERIFIED BY OWNER'S FACILITYPERSONNEL OR PROJECT ENGINEER, AND DESIGN/BUILD CONTRACTORSHALL PROVIDE TWO SETS OF THE FOLLOWING ITEMS TO OWNER'SPROJECT ENGINEER: -TRAINING DOCUMENTATION FOR INSTALLED EQUIPMENT. -EQUIPMENT INSTALLATION, OPERATION, AND MAINTENANCE MANUALS. -COPY OF BUILDING PERMIT(S). -COPY OF CERTIFICATE OF OCCUPANCY AND DOCUMENTATION FROM ALL AHJ'S SHOWING ALL PERMITS HAVE BEEN CLOSED OUT. -WARRANTEE LETTER FROM DESIGN/BUILD CONTRACTOR TO OWNERINDICATING WORK IS GUARANTEED FOR A PERIOD OF TWO YEARS FROM THE DATE OF ACCEPTANCE. -ANY CITY, STATE, FEDERAL AGENCY DOCUMENTATION INDICATING THATINSPECTIONS HAVE BEEN MADE AND WRITTEN APPROVALS HAVE BEENGRANTED. -ACCEPTED AIR BALANCING REPORT FROM INDEPENDENT AIR BALANCECOMPANY -TEST RESULTS (COMPACTION, PAVING, FLOOR SLABS, AND THE LIKE) -COMPLETED TANK MANUFACTURER'S INSTALLATION CHECK LIST. -STATE REGISTRATION FORMS FOR REGULATED STORAGE TANKS. -COPY OF PIPING SYSTEMS INSTALLATION CHECKLIST FORUNDERGROUND PETROLEUM PIPE. -A CERTIFICATE THAT HYDROSTATIC TEST WERE PERFORMED PERMANUFACTURER'S INSTRUCTIONS ON THE TURBINE ENCLOSURE, SPILLBUCKETS AND DISPENSER BOXES, AND ALL PENETRATIONS, SEAMS, & JOINTS ARE WATER TIGHT. -RECORD DRAWINGS ON C/D IN AUTOCAD FORMAT RELEASE 14 ORHIGHER. -REPRODUCIBLE RECORD DRAWINGS (PROVIDE A THIRD SET TOLOCATION OF INSTALLATION) -THE FOLLOWING IS MINIMUM TESTING REQUIRED ALL TEST RESULTS MUST BE PROVIDED TO THE OWNER AS PART OF THE CLOSE OUT:PRIMARY & SECONDARY PIPING, GROUNDING RODS, SHEAR VALVES,OVERFILL ALARM, PRIMARY & SECONDARY TANKS AND E-STOP. 22. REVIEW WRITTEN SCOPE OF WORK BY RYDER ENGINEER. x BUILDING CODE: 2021 WASHINGTON STATE BUILDING CODE x MECHANICAL CODE: 2021 WASHINGTON STATE MECHANICAL CODE x PLUMBING CODE: 2021 WASHINGTON STATE PLUMBING CODE x ELECTRICAL CODE: 2023 NATIONAL ELECTRICAL CODE x FIRE CODE: 2021 WASHINGTON STATE FIRE CODE SCOPE OF WORK NOTES (CONT) G-2 CI V I L S P E C I F I C A T I O N S Re v . # Da t e D e s c r i p t i o n 17 8 5 0 W E S T V A L L E Y H W Y CI V I L U P G R A D E S TU K W I L A , W A 9 8 1 8 8 Jo b # : 22 5 - 5 3 . 0 0 Sc a l e : Da t e : Dr a w n B y : Ch e c k e d B y : 02 / 1 3 / 2 0 2 5 AS S H O W N INFINITY ENGINEERING GROUP, LLC 1208 East Kennedy Boulevard Suite 230 Tampa, Florida 33602 [p]: 813.434.4770[f]: 813.445.4211 www.iegroup.net Date RICHARD HERNANDEZ, P.E. WA REG. NO. 50841 JP NS RY D E R T U K W I L A L C - 0 5 4 9 Cert. of Auth. No. 603-536-314 GENERAL NOTE 1. ALL CONSTRUCTION SHALL BE EXECUTED AS SHOWN ON THESE PLANS. ANY REVISIONS AND/OR DEVIATIONS MUST BE APPROVED BY THE ENGINEER OF RECORD AND MAY RESULT IN ADDITIONAL PERMITTING EFFORTS THROUGH THE RELATED PERMITTING AGENCY. THE CONTRACTOR SHALL ACKNOWLEDGE THAT REVISIONS AND/OR DEVIATIONS MAY RESULT IN ADDITIONAL PERMITTING REQUIREMENTS AND POSSIBLY AFFECT SCHEDULING OF WORK. 2. UNLESS OTHERWISE NOTED ON PLANS, OR WITHIN THE PROJECT SPECIFICATIONS, ALL MATERIALS AND CONSTRUCTION ARE TO BE IN ACCORDANCE WITH DESIGN AND CONSTRUCTION STANDARDS OF THE PERMITTING AGENCY HAVING JURISDICTION; THE LOCALLY ADOPTED BUILDING CODE; AND ALL APPLICABLE LOCAL AND STATE CODES AND ORDINANCES. 3. PERMITS MAY BE REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY. THE CONTRACTOR IS TO ACKNOWLEDGE AND SECURE ALL PERMITS AND INSPECTIONS REQUIRED FOR WORK IN THE PUBLIC RIGHT-OF-WAY. 4. THIS PARCEL OF LAND MAY BE SUBJECT TO ANY AND ALL RECORDED (AND POSSIBLY UNRECORDED) EASEMENTS, RESTRICTIONS, AND COVENANTS. 5. PRIOR TO COMMENCEMENT OF WORK, THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES FOR VERIFICATION OF UTILITIES WITHIN THE LIMITS OF CONSTRUCTION. CALL AREA ONE CALL SYSTEM 48 HOURS PRIOR TO ANY EXCAVATION. 6. THE CONTRACTOR IS TO VERIFY ALL DIMENSIONS PRIOR TO THE START OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER IN A TIMELY MANNER. 7. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO PROTECT EXISTING PERMANENT SURVEY MONUMENTS AND BENCHMARKS FROM DISTURBANCE. SURVEY MONUMENTS DISTURBED BY CONSTRUCTION ARE TO BE REPLACED AND ADJUSTED VIA A LAND SURVEYOR REGISTERED IN THE STATE FOR WHICH THE PROJECT IS LOCATED. 8. THE CONTRACTOR SHALL COORDINATE WORK EFFORTS WITH THE OWNER TO MINIMIZE TRAFFIC INTERFERENCE AND OPERATIONS OF THE FACILITIES. 9. NO BLASTING OR BURNING IS ALLOWED ON THE PROJECT, UNLESS OTHERWISE DIRECTED OR NOTED BY THE ENGINEER. 10. IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS WILL BE ENCOUNTERED. HOWEVER IF MATERIALS SUSPECTED OF CONTAINING HAZARDOUS MATERIALS ARE ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY ENGINEER AND OWNER. HAZARDOUS MATERIALS WILL BE REMOVED BY OWNER UNDER A SEPARATE CONTRACT DEMOLITION AND CLEARING 1. DEMOLITION AND CLEARING OPERATIONS SHALL CONFORM TO APPLICABLE REGULATIONS RELATING TO ENVIRONMENTAL REQUIREMENTS DISPOSAL OF DEBRIS, BURNING OF DEBRIS ON SITE, AND USE OF HERBICIDES. 2. DEMOLITION WASTE SHALL BE DISPOSED OF IN A LEGAL MANNER. REMOVED DEMOLITION WASTE MATERIALS FROM PROJECT SITE AND DISPOSE OF WASTE IN AN EPA-APPROVED LANDFILL ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. DO NOT BURY OR BURN DEMOLITION WASTE ON-SITE. 3. HISTORIC ITEMS, RELICS, ANTIQUES, AND SIMILAR OBJECTS, INCLUDING, BUT NOT LIMITED TO CORNERSTONES AND THEIR CONTENTS, COMMEMORATIVE PLAQUES AND TABLETS, AND OTHER ITEMS OF INTEREST OF VALUE TO OWNER THAT MAY BE UNCOVERED DURING DEMOLITION REMAIN THE PROPERTY OF THE OWNER. 4. ARRANGE DEMOLITION SCHEDULE SO AS NOT TO INTERFERE WITH OWNER'S ON-SITE OPERATIONS OR OPERATIONS OF ADJACENT OCCUPIED BUILDINGS. 5. CONDUCT BUILDING DEMOLITION AND DEBRIS REMOVAL OPERATIONS TO ENSURE MINIMUM INTERFERENCE WITH ROADS, STREETS, WALKWAYS, AND OTHER ADJACENT OCCUPIED AND USED FACILITIES. DO NOT CLOSE OR OBSTRUCT STREETS, WALKS, WALKWAYS, OR OTHER ADJACENT OCCUPIED OR USED FACILITIES WITHOUT PERMISSION FROM OWNER AND AUTHORITIES HAVING JURISDICTION. 6. AUTHORITY FOR PERFORMING SITE CLEARING INDICATED ON PROPERTY ADJOINING OWNER'S PROPERTY MUST BE OBTAINED BY OWNER PRIOR TO COMMENCEMENT OF CLEARING. DO NOT PROCEED WITH WORK ON ADJOINING PROPERTY UNTIL DIRECTED BY ENGINEER. 7. PRIOR TO COMMENCEMENT OF DEMOLITION OPERATIONS: a. VERIFY THAT HAZARDOUS MATERIALS, IF PRESENT, HAVE BEEN REMEDIATED. b. REVIEW PROJECT RECORD DRAWINGS OF EXISTING BUILDING AND EXISTING SITE IMPROVEMENTS. c. INVENTORY AND RECORD THE CONDITION OF ITEMS TO BE REMOVED AND SALVAGED. TAKE DIGITAL PHOTOGRAPHS OR VIDEO OF PROJECT SITE AND SURROUNDING PROPERTIES, INCLUDING EXISTING ITEMS TO REMAIN DURING CONSTRUCTION OPERATIONS, RECORD CONDITIONS THAT MIGHT BE MISCONSTRUED AS DAMAGE CAUSED BY SALVAGE OPERATIONS. d. CLEAN, PACK, IDENTIFY, AND TRANSPORT SALVAGED ITEMS TO STORAGE AREA DESIGNATED BY OWNER. e. REMOVE REFRIGERANT FROM THE MECHANICAL EQUIPMENT ACCORDING TO 40 CFR 82 AND REGULATIONS OF AUTHORITIES HAVING JURISDICTION. f. COORDINATE ANY ADDITIONAL REQUIREMENTS FOR DEMOLISHING OR RELOCATING SITE MECHANICAL AND ELECTRICAL ITEMS WITH OWNER AND OTHER AUTHORITIES HAVING JURISDICTION. g. ASSURE THAT ANY REQUIRED INITIAL EROSION AND SEDIMENT CONTROL MEASURES ARE INSTALLED AND IN WORKING ORDER. h. LOCATE, IDENTIFY, DISCONNECT, AND SEAL OR CAP-OFF EXISTING UTILITIES SERVING BUILDINGS AND STRUCTURES TO BE DEMOLISHED. CUT AND REMOVE PIPE OR CONDUIT A MINIMUM OF 24 INCHES BELOW GRADE. CAP, VALVE, PLUG AND SEAL REMAINING PORTION OF PIPE OR CONDUIT. i. DO NOT START DEMOLITION WORK UNTIL UTILITY DISCONNECTION AND SEALING HAVE BEEN COMPLETED AND VERIFIED IN WRITING. 8. PRIOR TO COMMENCEMENT OF SITE CLEARING OPERATIONS, VERIFY THE FOLLOWING: a. TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES ARE IN PLACE AND IN WORKING ORDER. b. UTILITY LOCATOR SERVICE HAS DETERMINED AND FLAGGED THE LOCATION OF UNDERGROUND UTILITIES. c. EXISTING SITE IMPROVEMENTS AND UTILITIES TO REMAIN HAVE BEEN PROTECTED. d. BENCHMARKS AND SURVEY CONTROL POINTS HAVE BEEN PROTECTED FROM DISTURBANCE. e. TREES AND VEGETATION TO REMAIN (OR TO BE RELOCATED) HAVE BEEN LOCATED AND CLEARLY FLAGGED IN ACCORDANCE WITH TREE PROTECTION AND TRIMMING REQUIREMENTS. 9. COORDINATE UTILITY DEMOLITION AND ABANDONMENT WITH UTILITY COMPANY OR AUTHORITY HAVING JURISDICTION. 10. IN THE EVENT BUILDINGS IMMEDIATELY ADJACENT TO THE DEMOLITION AREA WILL BE OCCUPIED, CONDUCT SITE DEMOLITION SO OPERATIONS OF OCCUPIED BUILDINGS WILL NOT BE DISRUPTED. MAINTAIN ACCESS TO AND FROM EXISTING WALKWAYS, EXITS, AND OTHER FACILITIES USED BY OCCUPANTS OF ADJACENT BUILDINGS. 11. PROTECT EXISTING FACILITIES AND ADJACENT WALKWAYS, LOADING DOCKS, BUILDING ENTRIES, AND OTHER BUILDING FACILITIES DURING DEMOLITION OPERATIONS. MAINTAIN EXITS FROM EXISTING BUILDINGS. 12. ERECT TEMPORARY PROTECTION, SUCH AS WALKS, FENCES, RAILINGS, CANOPIES, AND COVERED PASSAGEWAYS, AS NECESSARY, AND AS REQUIRED BY AUTHORITIES HAVING JURISDICTION. REMOVE TEMPORARY BARRIERS AND PROTECTIONS WHERE HAZARDS NO LONGER EXIST. WHERE OPEN EXCAVATIONS OR OTHER HAZARDOUS CONDITIONS REMAIN, LEAVE TEMPORARY BARRIERS AND PROTECTIONS IN PLACE. 13. PROTECT EXISTING UTILITIES FROM DAMAGE DURING DEMOLITION OPERATIONS. MAINTAIN OPERATION OF UTILITY SERVICES TO REMAIN. PROVIDE AT LEAST 72 HOURS' NOTICE TO OCCUPANTS OF AFFECTED BUILDINGS IF SHUTDOWN OF SERVICE IS REQUIRED. 14. IF REMOVAL, RELOCATION, OR ABANDONMENT OF UTILITY SERVICES WILL AFFECT ADJACENT OCCUPIED BUILDINGS, MAINTAIN CONTINUITY OF SERVICE TO ADJACENT BUILDINGS BY PROVIDING TEMPORARY UTILITIES THAT BYPASS BUILDINGS AND STRUCTURES TO BE DEMOLISHED. TEMPORARY BYPASS SERVICES SHALL BE PROVIDED IN ACCORDANCE WITH UTILITY COMPANY OR AUTHORITIES HAVING JURISDICTION. 15. TEMPORARY SHORING: PROVIDE AND MAINTAIN INTERIOR AND EXTERIOR SHORING, BRACING, OR STRUCTURAL SUPPORT TO PRESERVE STABILITY AND PREVENT UNEXPECTED MOVEMENT OR COLLAPSE OF EXISTING IMPROVEMENTS BEING DEMOLISHED. ALL SHORING OPERATIONS SHALL BE DESIGNED BY A LICENSED PROFESSIONAL AND INSTALLED PER OSHA REQUIREMENTS. 16. DEMOLITION OF STRUCTURAL FRAMING MEMBERS SHALL PROCEED SYSTEMATICALLY, FROM HIGHER TO LOWER LEVEL. COMPLETE BUILDING DEMOLITION OPERATIONS ABOVE EACH FLOOR OR TIER BEFORE DISTURBING SUPPORTING MEMBERS ON THE NEXT LOWER LEVEL. REMOVE DEBRIS FROM ELEVATED PORTIONS OF THE BUILDING BY CHUTE, HOIST, OR OTHER DEVICE THAT WILL CONVEY DEBRIS TO GRADE LEVEL IN A CONTROLLED DESCENT. 17. CLEAN ADJACENT STRUCTURES AND IMPROVEMENTS OF DUST, DIRT, AND DEBRIS CAUSED BY BUILDING DEMOLITION OPERATIONS. RETURN ADJACENT AREAS TO CONDITION EXISTING BEFORE BUILDING DEMOLITION OPERATIONS BEGAN. 18. CLEARING AND GRUBBING: a. REMOVE OBSTRUCTIONS, TREES, SHRUBS, GRASS, AND OTHER VEGETATION TO PERMIT INSTALLATION OF NEW CONSTRUCTION. DO NOT REMOVE TREES, SHRUBS, AND OTHER VEGETATION INDICATED TO REMAIN OR TO BE RELOCATED. b. CUT MINOR ROOTS AND BRANCHES OF TREES INDICATED TO REMAIN IN A CLEAN AND CAREFUL MANNER AND ONLY WHERE SUCH ROOTS AND BRANCHES OBSTRUCT INSTALLATION OF NEW CONSTRUCTION. c. CLEAR UNDERGROWTH AND DEADWOOD WITHOUT DISTURBING SUBSOIL. d. GRIND STUMPS AND REMOVE ROOTS, OBSTRUCTIONS, AND DEBRIS EXTENDING TO A DEPTH BELOW EXPOSED SUBGRADE AS FOLLOWS: x FOOTINGS, SLABS ON GRADE AND BOTTOM SLABS OF STRUCTURES: 36 INCHES. x ROADS AND PAVEMENT AREAS: 18 INCHES. x AREAS TO BE GRASSED OR LANDSCAPED: 8 INCHES. x AREAS TO BE FILLED: 12 INCHES. e. USE ONLY HAND METHODS FOR GRUBBING WITHIN TREE PROTECTION ZONES. f. CHIP REMOVED TREE BRANCHES AND DISPOSE OF OFF-SITE. g. UNLESS FURTHER EXCAVATION OF EARTHWORK IS INDICATED, FILL DEPRESSIONS CAUSED BY CLEARING AND GRUBBING OPERATIONS WITH SATISFACTORY SOIL MATERIAL. PLACE FILL MATERIAL IN HORIZONTAL LAYERS NOT EXCEEDING A LOOSE DEPTH OF 8 INCHES, AND COMPACT EACH LAYER TO A DENSITY EQUAL TO ADJACENT ORIGINAL GROUND. 19. TOPSOIL STRIPPING: a. REMOVE SOD AND GRASS BEFORE STRIPPING TOPSOIL. b. STRIP TOPSOIL TO WHATEVER DEPTHS ARE ENCOUNTERED IN A MANNER TO PREVENT INTERMINGLING WITH UNDERLYING SUBSOIL OR OTHER WASTE MATERIALS. REMOVE SUBSOIL AND NON-SOIL MATERIALS FROM TOPSOIL, INCLUDING TRASH, DEBRIS, WEEDS, ROOTS, AND OTHER WASTE MATERIALS. c. STOCKPILE TOPSOIL MATERIALS AWAY FROM EDGE OF EXCAVATIONS WITHOUT INTERMIXING WITH SUBSOIL. GRADE AND SHAPE STOCKPILES TO DRAIN SURFACE WATER. COVER TO PREVENT WINDBLOWN DUST. LIMIT HEIGHT OF TOPSOIL STOCKPILES TO 72 INCHES. DO NOT STOCKPILE TOPSOIL WITHIN TREE PROTECTION ZONES. STOCKPILE SURPLUS TOPSOIL TO ALLOW FOR RESPREADING DEEPER TOPSOIL. 20. SITE IMPROVEMENTS: a. REMOVE EXISTING ABOVE- AND BELOW-GRADE IMPROVEMENTS AS INDICATED AND AS NECESSARY TO FACILITATE NEW CONSTRUCTION. REMOVE SLABS, PAVING, CURBS, GUTTERS, AND AGGREGATE BASE AS INDICATED. b. UNLESS EXISTING FULL-DEPTH JOINTS COINCIDE WITH LINE OF DEMOLITION, NEATLY SAW-CUT LENGTH OF EXISTING PAVEMENT TO REMAIN BEFORE REMOVING EXISTING PAVEMENT. SAWCUT ALL FACES VERTICALLY. c. PAINT CUT ENDS OF STEEL REINFORCEMENT IN CONCRETE TO REMAIN TO PREVENT CORROSION. 21. DISPOSAL: a. REMOVE SURPLUS SOIL MATERIAL, UNSUITABLE TOPSOIL, OBSTRUCTIONS, DEMOLISHED MATERIALS, AND WASTE MATERIALS, INCLUDING TRASH AND DEBRIS, AND LEGALLY DISPOSE OF THEM OFF OWNER'S PROPERTY. b. REMOVE AND TRANSPORT DEBRIS AND RUBBISH IN A MANNER THAT WILL PREVENT SPILLAGE ON STREETS OR ADJACENT AREAS. CLEAN UP SPILLAGE FROM STREETS AND ADJACENT AREAS. c. COMPLY WITH FEDERAL, STATE AND LOCAL HAULING AND DISPOSAL REGULATIONS. d. SEPARATE RECYCLABLE MATERIALS PRODUCED DURING SITE CLEARING FROM OTHER NON-RECYCLABLE STORE OR STOCKPILE WITHOUT INTERMIXING WITH OTHER MATERIALS AND TRANSPORT THEM TO RECYCLING FACILITIES. EARTHWORK 1. IN THE EVENT OF ANY UNFORESEEN CONDITIONS THAT ARE ENCOUNTERED AND NOT COVERED BY THESE NOTES DURING GRADING OPERATIONS, THE ENGINEER SHALL BE IMMEDIATELY NOTIFIED FOR DIRECTION. 2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PERFORM ALL NECESSARY CUTS AND FILLS WITHIN THE LIMITS OF THIS PROJECT AND RELATED OFF-SITE WORK SO AS TO ESTABLISH THE DESIRED SUBGRADE, FINISH GRADES AND SLOPES SPECIFIED WITHIN THE PLANS. 3. ADEQUATE SHORING IS TO BE DESIGNED AND PROVIDED BY THE CONTRACTOR TO PREVENT UNDERMINING OF ANY ADJACENT FEATURES OR FACILITIES AND/OR CAVING OF THE EXCAVATION. ALL SHORING AND ASSOCIATED TEMPORARY STRUCTURES SHALL BE DESIGNED BY A LICENSED PROFESSIONAL AND INSTALLED PURSUANT TO OSHA REQUIREMENTS. SOIL MATERIALS: 1. UNSATISFACTORY SOILS CONSIST OF SOIL CLASSIFICATION GROUPS ML, OL, CH, MH, OH, AND PT, OR A COMBINATION OF THESE GROUPS. UNSATISFACTORY SOILS ALSO INCLUDE SATISFACTORY SOILS NOT MAINTAINED WITHIN 3 PERCENT OF OPTIMUM MOISTURE CONTENT AT TIME OF COMPACTION. 2. SATISFACTORY SOILS: ASTM D 2487 SOIL CLASSIFICATION GROUPS AS IDENTIFIED ON THE DRAWINGS, OR A COMBINATION OF THESE GROUPS; FREE OF ROCK OR GRAVEL LARGER THAN 3 INCHES IN ANY DIMENSION, DEBRIS WASTE, FROZEN MATERIALS, VEGETATION, AND OTHER DELETERIOUS MATERIAL. SUBGRADE INSPECTION: 1. PROOF-ROLL SUBGRADE BELOW THE BUILDING SLABS AND PAVEMENTS WITH HEAVY PNEUMATIC-TIRED EQUIPMENT TO IDENTIFY SOFT POCKETS AND AREAS OF EXCESS YIELDING. DO NOT PROOF-ROLL WET OR SATURATED SUBGRADES. a. COMPLETELY PROOF-ROLL SUBGRADE IN TWO DIRECTIONS, REPEATING PROOF ROLLING IN DIRECTION PERPENDICULAR TO FIRST DIRECTION. LIMIT VEHICLE SPEED TO 3 MPH, b. PROOF-ROLL WITH A LOADED 10-WHEEL, TANDEM-AXLE DUMP TRUCK WEIGHING NOT LESS THAN 15 TONS. c. EXCAVATE SOFT SPOTS, UNSATISFACTORY SOILS. AND AREAS OF EXCESSIVE PUMPING OR RUTTING, AS DETERMINED BY ENGINEER AND REPLACE WITH COMPACTED BACKFILL OR FILL AS DIRECTED. 2. RECONSTRUCT SUBGRADES DAMAGED BY FREEZING TEMPERATURES, FROST, RAIN, ACCUMULATED WATER, OR CONSTRUCTION ACTIVITIES AS DIRECTED BY ENGINEER, WITHOUT ADDITIONAL COMPENSATION. BACKFILL: 1. THE CONTRACTOR SHALL PLACE AND COMPACT BACKFILL IN EXCAVATIONS PROMPTLY, BUT NOT BEFORE COMPLETING THE FOLLOWING: a. CONSTRUCTION BELOW FINISH GRADE INCLUDING, WHERE APPLICABLE, SUBDRAINAGE, DAMP PROOFING, WATERPROOFING, AND PERIMETER INSULATION. b. SURVEYING LOCATIONS OF UNDERGROUND UTILITIES FOR RECORD DRAWINGS. c. TESTING AND INSPECTING UNDERGROUND UTILITIES. d. REMOVING CONCRETE FORMWORK. e. REMOVING TRASH AND DEBRIS. f. REMOVING TEMPORARY SHORING AND BRACING, AND SHEETING. g. INSTALLING PERMANENT OR TEMPORARY HORIZONTAL BRACING ON HORIZONTALLY SUPPORTED WALLS. COMPACTION OF SOIL BACKFILLS AND FILLS: 1. CONTRACTOR SHALL PLACE BACKFILL AND FILL MATERIALS IN LAYERS NOT MORE THAN 8-INCHES IN LOOSE DEPTH FOR MATERIAL COMPACTED BY HEAVY COMPACTION EQUIPMENT, AND NOT MORE THAN 4-INCHES IN LOOSE DEPTH FOR MATERIAL COMPACTED BY HAND-OPERATED TAMPERS. 2. PLACE BACKFILL AND FILL SOIL MATERIALS EVENLY ON ALL SIDES OF STRUCTURES TO REQUIRED ELEVATIONS, AND UNIFORMLY ALONG THE FULL LENGTH OF EACH STRUCTURE. 3. COMPACT SOIL MATERIALS TO NOT LESS THAN THE PLAN SPECIFIED PERCENTAGES OF MAXIMUM DRY UNIT WEIGHT ACCORDING TO ASTM D 698 OR ASTM D 1557. (SEE CIVIL DETAILS FOR SUMMARY OF TRENCH BACKFILL AND BEDDING MATERIALS AND PLACEMENT SPECIFICATIONS). GRADING: 1. GENERAL: UNIFORMLY GRADE AREAS TO A SMOOTH SURFACE. FREE OF IRREGULAR SURFACE CHANGES. COMPLY WITH COMPACTION REQUIREMENTS AND GRADE TO DETAILED/INDICATED CROSS-SECTIONS. LINES, AND ELEVATIONS INDICATED IN PLANS. PROVIDE A SMOOTH TRANSITION BETWEEN ADJACENT EXISTING GRADES AND NEW GRADES. CUT OUT SOFT SPOTS, FILL LOW SPOTS, AND TRIM HIGH SPOTS TO COMPLY WITH REQUIRED SURFACE TOLERANCES. 2. SITE GRADING: SLOPE GRADES TO DIRECT WATER AWAY FROM BUILDINGS AND TO PREVENT PONDING. FINISH SUBGRADES TO REQUIRED ELEVATIONS WITHIN THE FOLLOWING TOLERANCES: a. LAWN OR UNPAVED AREAS: PLUS OR MINUS ONE (1) INCH. b. WALKS: PLUS OR MINUS ONE (1) INCH. c. PAVEMENTS: PLUS OR MINUS ONE-HALF (1/2) INCH. d. GRADING INSIDE BUILDING LINES: FINISH SUBGRADE TO A TOLERANCE OF ONE-HALF (1/2) INCH WHEN TESTED WITH A 10-FOOT STRAIGHTEDGE. 3. SUBBASE AND BASE COURSES: a. PLACE SUBBASE AND BASE COURSE ON SUBGRADES FREE OF MUD, FROST, SNOW, OR ICE. b. PLACE SUBBASE AND BASE COURSE 6 INCHES OR LESS IN COMPACTED THICKNESS IN A SINGLE LAYER. c. PLACE SUBBASE AND BASE COURSE EXCEEDING 6 INCHES IN COMPACTED THICKNESS IN LAYERS OF EQUAL THICKNESS, WITH NO COMPACTED LAYER MORE THAN 6 INCHES THICK OR LESS THAN 3 INCHES. 4. COMPACT SUBBASE AND BASE COURSE AT OPTIMUM MOISTURE CONTENT TO REQUIRED GRADES, LINES. CROSS SECTIONS. AND THICKNESS ACCORDING TO ASTM D 698 OR ASTM D 1557, AS INDICATED ON THE DRAWING DETAILS. FIELD QUALITY CONTROL: 1. THE TESTING AGENCY WILL INSPECT AND TEST SUBGRADES AND EACH FILL OR BACKFILL LAYER. CONTRACTOR SHALL PROCEED WITH SUBSEQUENT EARTHWORK ONLY AFTER TEST RESULTS FOR PREVIOUSLY COMPLETED WORK COMPLY WITH REQUIREMENTS. 2. FOOTING SUBGRADE: AT FOOTING SUBGRADES, AT LEAST ONE TEST OF EACH SOIL STRATUM WILL BE PERFORMED TO VERIFY DESIGN BEARING CAPACITIES. SUBSEQUENT VERIFICATION AND APPROVAL OF OTHER FOOTING SUBGRADES MAY BE BASED ON A VISUAL COMPARISON OF SUBGRADE WITH TESTED SUBGRADE WHEN APPROVED BY ENGINEER. 3. THE TESTING AGENCY WILL TEST COMPACTION OF SOILS IN PLACE ACCORDING TO ASTM D 1556, ASTM D 2167, ASTM D 2922, AND ASTM D 2937, AS APPLICABLE. TESTS WILL BE PERFORMED AT THE FOLLOWING LOCATIONS AND FREQUENCIES: a. PAVED AND BUILDING SLAB AREAS: AT SUBGRADE AT EACH COMPACTED FILL AND BACKFILL LAYER, AT LEAST 1 TEST FOR EVERY 10,000 SQ. FT. OR LESS OF PAVED AREA OR BUILDING SLAB, BUT IN NO CASE FEWER THAN 3 TESTS. b. FOUNDATION WALL BACKFILL: AT EACH COMPACTED BACKFILL LAYER, AT LEAST 1 TEST FOR EACH 100 FEET OR LESS OF WALL LENGTH, BUT NO FEWER THAN 2 TESTS. c. TRENCH BACKFILL: AT EACH COMPACTED INITIAL AND FINAL BACKFILL LAYER, AT LEAST 1 TEST FOR EACH 150 FEET OR LESS OF TRENCH LENGTH, BUT NO FEWER THAN 2 TESTS. 5. IF THE TESTING AGENCY REPORTS THAT SUBGRADES, FILLS, OR BACKFILLS HAVE NOT ACHIEVED DEGREE OF COMPACTION SPECIFIED, SCARIFY AND MOISTEN OR AERATE, OR REMOVE AND REPLACE SOIL TO DEPTH REQUIRED; RECOMPACT AND RETEST UNTIL SPECIFIED COMPACTION IS OBTAINED. 6. ALL FIELD QUALITY CONTROL TESTS THAT FAIL TO MEET THE SPECIFIED COMPACTION DENSITY SHALL BE REPORTED TO THE ENGINEER. GENERAL UTILITY NOTES 1. PRIOR TO COMMENCEMENT OF WORK, THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES FOR VERIFICATION OF UTILITIES WITHIN THE LIMITS OF CONSTRUCTION. CALL THE AREA ONE CALL SYSTEM 48 HOURS PRIOR TO ANY EXCAVATION. 2. THE CONTRACTOR IS TO VERIFY ALL DIMENSIONS PRIOR TO THE START OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER. 3. THE CONTRACTOR SHALL COORDINATE WORK EFFORTS WITH THE OWNER TO MINIMIZE TRAFFIC INTERFERENCE AND OPERATIONS OF THE FACILITIES. 4. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO PROTECT EXISTING PERMANENT SURVEYING MONUMENTS AND BENCHMARKS FROM DISTURBANCE. SURVEY MONUMENTS DISTURBED BY CONSTRUCTION ARE TO BE REPLACED AND ADJUSTED VIA A LAND SURVEYOR REGISTERED IN THE STATE FOR WHICH THE PROJECT IS LOCATED. 5. EXISTING UTILITIES SHOWN HEREIN ARE BASED ON AVAILABLE RECORDS AND FIELD INVESTIGATIONS. THE CONTRACTOR SHALL VERIFY HORIZONTAL AND VERTICAL LOCATIONS OF UTILITIES PRIOR TO EXCAVATION WITHIN WORK AREAS. THE ENGINEER SHALL BE NOTIFIED UPON DISCOVERY OF ANY DISCREPANCIES THAT WILL AFFECT INSTALLATION OF WORK OR DISCOVERY OF UNCHARTED UTILITIES WHICH MAY REQUIRE RELOCATION. NOTIFICATION SHALL BE DONE IN A TIMELY MANNER. 6. WHERE APPLICABLE, THE CONTRACTOR SHALL MAINTAIN ALL FENCING, SIGNS, DETOURS, FLAGMEN, SIGNALS, ETC., FOR ANY OPEN TRENCHES, HOLES OR PITS. ALL TRENCHES, HOLES OR PITS SHALL BE CLOSED OR PROTECTED BY BARRICADES AT THE END OF THE DAY. 7. PERMITS MAY BE REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY. THE CONTRACTOR IS TO ACKNOWLEDGE AND SECURE ALL PERMITS AND INSPECTIONS REQUIRED FOR WORK WITHIN PUBLIC RIGHT-OF-WAY. 8. THE CONTRACTOR SHALL MAINTAIN RECORD DRAWINGS DURING CONSTRUCTION WHICH SHOW THE CONSTRUCTED CONDITIONS OF ALL WORK INSTALLED. SEE "AS-BUILT” REQUIREMENTS FOR ADDITIONAL INFORMATION. 9. ALL VALVE BOXES, METER BOXES, VAULTS, CLEANOUTS, HOLE COVERS, FIRE HYDRANTS AND OTHER APPURTENANCES THAT ARE TO REMAIN IN SERVICE WITHIN THE PROJECT AREA SHALL BE ADJUSTED TO CONFORM TO FINISHED GRADE. 10. ALL UNDERGROUND UTILITIES MUST BE IN PLACE, TESTED AND INSPECTED AS REQUIRED PRIOR TO BASE AND SURFACE CONSTRUCTION. 11. IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL UTILITY COMPANIES TO DISCONNECT OR REMOVE THEIR FACILITIES PRIOR TO REMOVING OR DEMOLISHING ANY EXISTING STRUCTURES FROM THE SITE. ALL UTILITIES INCLUDING, BUT NOT NECESSARILY LIMITED TO, THE FOLLOWING SHOULD BE CONTACTED BY THE CONTRACTOR: 1. GAS 2. TELEPHONE 3. CABLE 4. POWER 5. CITY/COUNTY WATER AND SEWER 6. CITY/COUNTY/STATE TRAFFIC SIGNAL UTILITY (FIBER, HARDWIRE TRAFFIC SIGNAL INTERCONNECT) 13. THE LOCATION OF ALL EXISTING UTILITIES SHOWN ON THE PLANS HAVE BEEN DETERMINED THE ENGINEER ASSUMES NO RESPONSIBILITY FOR FROM THE BEST INFORMATION AVAILABLE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE VARIOUS ACCURACY. UTILITIES AND TO MAKE THE NECESSARY ARRANGEMENTS FOR ANY RELOCATIONS UTILITIES WITH THE OWNER OF THE UTILITY. THE CONTRACTOR SHALL EXERCISE OF THESE CAUTION WHEN CROSSING ANY UNDERGROUND UTILITY, WHETHER SHOWN ON THE PLANS OR LOCATED BY THE UTILITY COMPANY. ALL UTILITIES WHICH INTERFACE WITH THE PROPOSED CONSTRUCTION SHALL BE RELOCATED BY THE RESPECTIVE UTILITY COMPANIES AND THE CONTRACTOR SHALL COOPERATE WITH THE UTILITY COMPANIES DURING RELOCATION OPERATIONS. ANY DELAY OR INCONVENIENCE CAUSED TO THE CONTRACTOR BY THE VARIOUS UTILITIES SHALL BE INCIDENTAL TO THE CONTRACT AND NO EXTRA COMPENSATION WILL BE ALLOWED. 14. COLOR CODE FOR MARKING UNDERGROUND UTILITY LINES WHITE - PROPOSED EXCAVACTION. PINK - TEMPORARY SURVEY MARKINGS. RED - ELECTRIC POWER LINES, CABLES, CONDUIT AND LIGHTING CABLES. YELLOW - GAS, OIL, STEAM, PETROLEUM, OR GASEOUS MATERIALS. ORANGE - COMMUNICATION, ALARM OR SIGNAL LINES, CABLES OR CONDUIT. BLUE - POTABLE WATER. PURPLE - RECLAIMED WATER, IRRIGATION AND SLURRY LINES. GREEN - SEWERS AND DRAIN LINES. WATER SYSTEM NOTES 1. CONTRACTOR TO INSTALL TEMPORARY BLOW-OFFS AT THE END OF WATER SERVICE LATERALS TO ASSURE ADEQUATE FLUSHING AND DISINFECTION. 2. THRUST BLOCKING AND/OR RESTRAINED JOINTS SHALL BE PROVIDED AT ALL FITTINGS AND HYDRANTS IN ACCORDANCE WITH AWWA STANDARDS. 3. MATERIALS AND CONSTRUCTION METHODS FOR WATER DISTRIBUTION SYSTEM SHALL BE IN ACCORDANCE WITH THE LOCAL REGULATORY AGENCY CODES, PLANS, AND SPECIFICATIONS FOR CONSTRUCTION, LATEST REVISION THEREOF AND SUPPLEMENTAL SPECIFICATIONS THERETO. APPROVAL AND CONSTRUCTION OF ALL POTABLE WATER SERVICE MAIN EXTENSIONS AND CONNECTIONS MUST BE COORDINATED THROUGH THE LOCAL REGULATORY AGENCY DEPARTMENT OF PUBLIC UTILITIES. 4. ALL COMPONENTS OF THE WATER SYSTEM, INCLUDING FITTINGS, HYDRANTS, CONNECTIONS, AND VALVES SHALL REMAIN UNCOVERED UNTIL PROPERLY PRESSURE TESTED AND ACCEPTED BY THE OWNER'S ENGINEER. PRESSURE TESTS TO BE IN ACCORDANCE WITH WATER DEPARTMENT AND AWWA SPECIFICATIONS. CONTRACTOR TO NOTIFY OWNER'S ENGINEER AND WATER DEPARTMENT INSPECTORS 48 HOURS IN ADVANCE OF PERFORMING TESTS. 5. CONTRACTOR TO PERFORM CHLORINATION AND BACTERIOLOGICAL SAMPLING REQUIRED TO OBTAIN CLEARANCE OF DOMESTIC WATER SYSTEM THROUGH LOCAL REGULATORY AGENCIES. COPIES OF ALL BACTERIOLOGICAL TESTS TO BE SUBMITTED TO OWNER'S ENGINEER. ASPHALT PAVING 1. THE CONTRACTOR IS TO PROVIDE BARRICADES, SIGNS, FLASHERS, AND FLAG PERSONNEL AS NECESSARY TO INSURE THE SAFETY OF WORKERS AND VISITORS. ALL CONSTRUCTION SIGNING, BARRICADING, AND TRAFFIC DELINEATION IS TO CONFORM TO THE "MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES": LATEST EDITION. 2. ALL ASPHALT PAVING MATERIALS, WORKMANSHIP, AND INSTALLATION REQUIREMENTS SHALL COMPLY WITH THE STANDARD SPECIFICATIONS OF THE STATE DEPARTMENT OF TRANSPORTATION (D.O.T.) FOR THE STATE IN WHICH THE WORK OCCURS WITH SOME EXCLUSIONS. THE DOT PAYMENT PROCEDURES AND SAFETY REQUIREMENTS SHALL GENERALLY NOT APPLY. a. COARSE AGGREGATE. FINE AGGREGATE AND MINERAL FILLERS: IN ACCORDANCE WITH D.O.T. MATERIAL STANDARDS AND ASSOCIATED CONSTRUCTION SPECIFICATIONS. b. ASPHALT BINDER, ASPHALT CEMENT, PRIME COAT, AND TACK COAT: IN ACCORDANCE WITH D.O.T. MATERIAL STANDARDS AND ASSOCIATED CONSTRUCTION SPECIFICATIONS. c. JOINT SEALANT: ASTM 0 6690 OR AASHTO M 324. TYPE II OR III, HOT APPLIED, SINGLE COMPONENT, POLYMER-MODIFIED BITUMINOUS SEALANT. d. PAVEMENT-MARKING PAINT: IN ACCORDANCE WITH D.O.T. MATERIAL STANDARDS AND ASSOCIATED CONSTRUCTION SPECIFICATIONS. COLORS AS INDICATED. 3. DO NOT APPLY ASPHALT MATERIALS IF SUBGRADE IS FROZEN, WET, OR EXCESSIVELY DAMP; OR IF RAIN IS IMMINENT OR EXPECTED BEFORE TIME REQUIRED FOR ADEQUATE CURE. APPLY ONLY AT D.O.T. RECOMMENDED SURFACE TEMPERATURE. 4. INSTALLATION TOLERANCES: a. PAVEMENT THICKNESS: THE AVERAGE OF THE MEASURED THICKNESS OF THE PAVEMENT LAYERS SHALL MEET OR EXCEED THE REQUIRED THICKNESS FOR THOSE LAYERS, AND THE MINIMUM THICKNESS IN ANY ONE AREA SHALL NOT BE LESS THAN 0.25 INCHES BELOW THE REQUIRED THICKNESS. b. PAVEMENT SURFACE SMOOTHNESS: COMPACT EACH COURSE TO PRODUCE A SURFACE SMOOTHNESS WITHIN THE FOLLOWING TOLERANCES AS DETERMINED BY USING A 10-FOOT STRAIGHTEDGE APPLIED TRANSVERSELY OR LONGITUDINALLY TO PAVED AREAS: x BASE COURSE: 1/4 -INCH x SURFACE COURSE: 1/4 -INCH c. CROWNED SURFACES: TEST WITH CROWNED TEMPLATE CENTERED AND AT RIGHT ANGLE TO CROWN. MAXIMUM ALLOWABLE VARIANCE FROM TEMPLATE IS 1/4 -INCH. 5. PAVEMENT MARKINGS SHALL BE MADE WITH NON-THERMOPLASTIC ACRYLIC MARKING PAINT MEETING THE DOT MATERIAL REQUIREMENTS. ALLOW PAVING TO AGE FOR 30 DAYS BEFORE STARTING PAVEMENT MARKING. PROCEED WITH PAVEMENT MARKING ONLY ON CLEAN, DRY SURFACES. SWEEP AND CLEAN SURFACE TO ELIMINATE LOOSE MATERIAL AND DUST. APPLY PAINT WITH MECHANICAL EQUIPMENT TO PRODUCE PAVEMENT MARKINGS, OF DIMENSIONS AND COLORS INDICATED, WITH UNIFORM, STRAIGHT EDGES. APPLY AT MANUFACTURER'S RECOMMENDED RATES TO PROVIDE A MINIMUM WET FILM THICKNESS OF 15 MILS AND ONLY AT MANUFACTURER'S RECOMMENDED AMBIENT AND SURFACE TEMPERATURES. GRAPHIC SCALE0 1 INCH = FT. 40201010 20 N SITE NE 1/4, NW 1/4, SEC. 36, T. 23 N., R. 04 E., W.M. BB A DA T E RE V I S I O N D R N JOB NO. DRAWN BY: CHECKED BY: DATE: SHEET 2 0 1 9 , B B A L A N D S U R V E Y I N G , I N C . , A L L R I G H T S R E S E R V E D C AL T A / N S P S L A N D T I T L E S U R V E Y NA V I X E N G I N E E R I N G 17 8 5 0 W V A L L E Y H W Y TU W I L A , W A 9 8 1 8 8 MAB RSN 19282 07/12/2019 1 OF 2 VICINITY MAP NTS LEGEND VERTICAL DATUM REFERENCES BASIS OF BEARINGS LEGAL DESCRIPTION LEGAL DESCRIPTION AS SURVEYED 1. 2. 3. 4. 5. 6. LOT LINE ADJUSTMENT, CITY OF RENTON FILE NO. LUA-06-095-LLA, VOL. 210, PGS. 192-210, RECORDS OF KING COUNTY, WA. 181 SO. CORP. LIMITS OF TUKWILA TO FOSTER INTERCHANGE, APPROVED 05/16/68, RECORDS OF WSDOT RECORD OF SURVEY, VOL. 9, PG. 192, RECORDS OF KING COUNTY, WA. RECORD OF SURVEY, VOL. 12, PG. 168, RECORDS OF KING COUNTY, WA. CITY OF RENTON SHORT PLAT NO. 346-79, VOL. 19, PG. 81, RECORDS OF KING COUNTY, WA. RECORD OF SURVEY, VOL. 268, PG. 11, RECORDS OF KING COUNTY, WA. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. EASEMENT, INCLUDING TERMS AND PROVISIONS CONTAINED THEREIN:RECORDING DATE: OCTOBER 5, 1971 RECORDING INFORMATION: 7110050390 IN FAVOR OF: CITY OF RENTONFOR: PUBLIC UTILITIES AFFECTS: AS DESCRIBED THEREIN.(SHOWN HEREON) COVENANTS, CONDITIONS, RESTRICTIONS AND/OR EASEMENTS:RECORDED: APRIL 2, 1979 RECORDING NO.: 7904020670(NOT PLOTTABLE) THE TERMS AND PROVISIONS CONTAINED IN THE DOCUMENT ENTITLED"AGREEMENT" RECORDED OCTOBER 31, 1979 AS RECORDING NO. 7910310648 OF OFFICIAL RECORDS.(NOT PLOTTABLE) EASEMENT, INCLUDING TERMS AND PROVISIONS CONTAINED THEREIN:RECORDING DATE: OCTOBER 31, 1979 RECORDING INFORMATION: 7910310780IN FAVOR OF: PUGET SOUND POWER AND LIGHT COMPANY, A WASHINGTON CORPORATION FOR: THE RIGHT TO CONSTRUCT, OPERATE, MAINTAIN, REPAIR REPLACE ANDENLARGE AND UNDERGROUND ELECTRIC TRANSMISSION AND/OR DISTRIBUTION SYSTEMAFFECTS: AS DESCRIBED THEREIN. (10' WIDE CENTERED ON EXISTING FACILITIES - NOT PLOTTED) EASEMENT, INCLUDING TERMS AND PROVISIONS CONTAINED THEREIN: RECORDING DATE: APRIL 28, 1980RECORDING INFORMATION: 8004280537 IN FAVOR OF: CITY OF RENTON FOR: PUBLIC UTILITIES (INCLUDING WATER AND SEWER)AFFECTS: AS DESCRIBED THEREIN (SHOWN HEREON) RESTRICTIONS, CONDITIONS, DEDICATIONS, NOTES, EASEMENTS AND PROVISIONS, IF ANY, AS CONTAINED AND/OR DELINEATED ON THE FACE OFTHE TUKWILA SHORT PLAT NO. 88-3-SS RECORDED NOVEMBER 18, 1988 AS RECORDING NO. 8811180199, IN KING COUNTY, WASHINGTON.(SHOWN HEREON) EASEMENT, INCLUDING TERMS AND PROVISIONS CONTAINED THEREIN:RECORDING DATE: JANUARY 10, 1989 RECORDING INFORMATION: 8901101394IN FAVOR OF: NICK SCIOLA, JR. AND PATRICIA ANN SCIOLA, HUSBAND AND WIFE FOR: SEWER PURPOSESAFFECTS: AS DESCRIBED THEREIN. (SHOWN HEREON) EASEMENT, INCLUDING TERMS AND PROVISIONS CONTAINED THEREIN: RECORDING DATE: JANUARY 10, 1989RECORDING INFORMATION: 8901101395 IN FAVOR OF: NICK SCIOLA, JR. AND PATRICIA ANN SCIOLA, HUSBAND ANDWIFE FOR: STORM DRAINAGE PURPOSES AFFECTS: AS DESCRIBED THEREIN(SHOWN HEREON) EASEMENT, INCLUDING TERMS AND PROVISIONS CONTAINED THEREIN: RECORDING DATE: JANUARY 10, 1989 RECORDING INFORMATION: 8901101395IN FAVOR OF: NICK SCIOLA, JR. AND PATRICIA ANN SCIOLA, HUSBAND AND WIFEFOR: ACCESS AND UTILITY PURPOSES AFFECTS: AS DESCRIBED THEREIN. (NOT PLOTTED - "AREA IMMEDIATELY ADJACENT TO" STORM DRAINAGEEASEMENT FOR CONSTRUCTION AND MAINTENANCE) THE TERMS, PROVISIONS AND EASEMENT(S) CONTAINED IN THE DOCUMENT ENTITLED "AGREEMENT FOR ACCESS AND UTILITY EASEMENT" RECORDED JANUARY 10, 1989 AS RECORDING NO. 8901101396 OF OFFICIAL RECORDS.(SHOWN HEREON) THE TERMS, PROVISIONS AND EASEMENT(S) CONTAINED IN THE DOCUMENT ENTITLED "AGREEMENT FOR RECIPROCAL PARKING AND ACCESS EASEMENT" RECORDED JANUARY 10, 1989 AS RECORDING NO. 8901101397OF OFFICIAL RECORDS. (SHOWN HEREON) EASEMENT, INCLUDING TERMS AND PROVISIONS CONTAINED THEREIN: RECORDING DATE: JULY 03, 1990RECORDING INFORMATION: 9007031149 IN FAVOR OF: NICK SCIOLA AND PATRICIA ANN SCIOLA, HUSBAND AND WIFEFOR: DRAINAGE AFFECTS: AS DESCRIBED THEREIN. (SHOWN HEREON) EASEMENT, INCLUDING TERMS AND PROVISIONS CONTAINED THEREIN:RECORDING DATE: FEBRUARY 21, 1991 RECORDING INFORMATION: 9102211113 IN FAVOR OF: CITY OF RENTON, A MUNICIPAL CORPORATIONFOR: PUBLIC UTILITIES (INCLUDING WATER AND SEWER) WITH NECESSARY APPURTENANCESAFFECTS: AS DESCRIBED THEREIN. (SHOWN HEREON) SIDE SEWER EASEMENT, INCLUDING TERMS AND PROVISIONS CONTAINED THEREIN:LOCATION: ALONG THE LINE AS CONSTRUCTED WIDTH: 10 FEET RECORDING NO.: 9106191617, RECORDED JUNE 19, 1991(SHOWN HEREON) MATTERS OF TITLE PARCEL A : LOT B, CITY OF TUKWILA SHORT PLAT NO. 88-3-SS AS RECORDED NOVEMBER 18, 1988 UNDER RECORDING NO. 8811180199, RECORDS OF KING COUNTY,STATE OF WASHINGTON. PARCEL B : AN EASEMENT FOR INGRESS AND EGRESS AS DELINEATED ACROSS PARCEL A,CITY OF TUKWILA SHORT PLAT NO. 88-3-SS AS RECORDED NOVEMBER 18, 1988 UNDER RECORDING NO. 8811180199, RECORDS OF KING COUNTY, STATE OF WASHINGTON. THE FOLLOWING IS A METES AND BOUNDS LEGAL DESCRIPTION OF THESUBJECT PARCEL BOUNDARY LINES, AS SURVEYED. THIS LEGAL DESCRIPTION DOES NOT PURPORT TO SUPERCEDE THE LEGAL DESCRIPTION AS CURRENTLY FOUND IN TITLE. THAT PORTION OF THE NORTHWEST QUARTER OF SECTION 36, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., SITUATE IN THE CITY OF TUKWILA, KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: COMMENCING AT THE INTERSECTION OF THE EAST RIGHT-OF-WAY LINE OF THE WEST VALLEY HIGHWAY (SR 181) AND THE NORTH LINE OF THE SOUTH 480.00 FEET OF THE NORTH HALF OF SAID NORTHWEST QUARTER OF SECTION 36; THENCE SOUTH 88°22'12" EAST, ALONG SAID NORTH LINE, 533.49 FEET, TO THE POINT OF BEGINNING; THENCE SOUTH 88°22'12" EAST, CONTINUING ALONG SAID NORTH LINE 378.62 FEET, TO THE WEST RIGHT-OF-WAY LINE OF THE PUGET SOUND ELECTRIC RAILWAY; THENCE NORTH 01°27'12" WEST, ALONG SAID WEST RIGHT-OF-WAY LINE OF THE PUGET SOUND ELECTRIC RAILWAY, 306.44 FEET, TO THE NORTH LINE OF THE SOUTH 786.00 FEET OF SAID NORTH HALF; THENCE NORTH 88°22'12" WEST, ALONG SAID NORTH LINE OF THE SOUTH 786.00 FEET, 362.14 FEET, TO A POINT WHICH BEARS NORTH 01°37'48" EAST FROM THE POINT OF BEGINNING; THENCE SOUTH 01°37'48" WEST 306.00 FEET, TO THE POINT OF BEGINNING. WASHINGTON COORDINATE SYSTEM, NAD83(2011), NORTH ZONE, DERIVED FROM WRSN REFERENCE NETWORK - ACCEPTED THE CALCULATED BEARING OF N 88°36'34" W, BETWEEN POINTS ALONG THE CENTERLINE OFSW 43RD ST, BASED ON FOUND MONUMENTS IN CASE. NAVD88 - ELEVATIONS SHOWN ON THIS DRAWING WERE DERIVED FROM INFORMATION PROVIDED BY CITY OF KIRKLAND SURVEY CONTROLDATABASE. POINT ID NO. 3537 - 3" BRASS DISK, SET FLUSH WITH CONCRETESIDEWALKSTAMPED WITH THE AGENCY. FROM THE INTERSECTION OF WEST VALLEY HIGHWAY AND S 180TH ST, GO WEST TO THE INTERSECTION WITH S180TH ST AND SPERRY DRIVE. THE MONUMENT IS LOCATED AT THE NORTHWEST CORNER OF THE INTERSECTION AND SET IN THE CONCRETE SIDEWALK. ELEVATION: 29.52 FEET SURVEYOR'S NOTES 1. THE INFORMATION ON THIS MAP REPRESENTS THE RESULTS OF A SURVEY MADE IN JULY 2019 AND CAN ONLY BE CONSIDERED ASINDICATING THE GENERAL CONDITIONS EXISTING AT THAT TIME. 2. INSTRUMENTATION FOR THIS SURVEY WAS A 3-SECOND LEICA TS16ROBOTIC TOTAL STATION AND/OR LEICA GS16 GPS RECEIVER. PROCEDURES USED IN THIS SURVEY MEET OR EXCEED STANDARDS SETBY WAC 332-130-090. 3. UTILITIES SHOWN ON THIS SURVEY ARE BASED UPON ABOVE GROUNDOBSERVATIONS AND AS-BUILT PLANS WHERE AVAILABLE. ACTUAL LOCATIONS OF UNDERGROUND UTILITIES MAY VARY AND UTILITIES NOTSHOWN ON THIS SURVEY MAY EXIST ON THIS SITE. 4. SUBJECT PROPERTY TAX PARCEL NO. 3623049062. 5. APPROXIMATE SUBJECT PROPERTY AREA IS:113,336± S.F. (2.6018± ACRES) 6. ALL TITLE INFORMATION SHOWN ON THIS MAP HAS BEEN EXTRACTEDFROM FIRST AMERICAN TITLE INSURANCE COMPANY'S "SUBDIVISION GUARANTEE", ORDER NO. NCS-967049-MIA, DATED JUNE 20, 2019. INPREPARING THIS MAP, BBA LAND SURVEYING HAS CONDUCTED NO INDEPENDENT TITLE SEARCH NOR IS BBA LAND SURVEYING AWARE OF ANY TITLE ISSUES AFFECTING THE SURVEYED PROPERTY OTHER THANTHOSE SHOWN ON THE MAP AND DISCLOSED BY THE REFERENCED ALTA COMMITMENT FOR TITLE INSURANCE. BBA LAND SURVEYING HASRELIED WHOLLY ON FIRST AMERICAN TITLE INSURANCE COMPANY'S REPRESENTATIONS OF THE TITLE'S CONDITION TO PREPARE THIS SURVEY AND BBA LAND SURVEYING QUALIFIES THE MAP'S ACCURACYAND COMPLETENESS TO THAT EXTENT. 7. THE PROPERTY IS LOCATED WITHIN AN AREA HAVING ZONE DESIGNATION "X", PER THE FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA), ON FLOOD INSURANCE RATE MAP NO. 53033C0978 F,WITH AN EFFECTIVE DATE OF MAY 16, 1995 FOR COMMUNITY NO. 530091, IN KING COUNTY, STATE OF WASHINGTON, WHICH IS THECURRENT FLOOD INSURANCE RATE MAP FOR THE COMMUNITY IN WHICH THE PROPERTY IS SITUATED. 8. SUBJECT PROPERTY IS ZONED "C/LI", PRESENT USE IS SERVICE BUILDING. SETBACK REQUIREMENTS: FRONT = 25', SECOND FRONT 12.5', SIDE = 5', REAR = 5' MAXIMUM BUILDING HEIGHT: 4 STORIES OR 45' PARKING REQUIREMENT: SEE TMC CHAPTER 18.30 THE ABOVE ZONING INFORMATION IS PER CITY OF TUKWILA ZONING CODE, SECTION 18.30.080 BASIC DEVELOPMENT STANDARDS. IT WAS NOT PROVIDED BY THE INSURER AS IS REQUIRED BY THE 2016 ALTA/NSPS STANDARDS FOR LAND TITLE SURVEYS. 9. THE TOTAL NUMBER OF DESIGNATED PARKING SPACES ON THE PROPERTY IS 72, INCLUDING 21 STANDARD, 1 HANDICAP, 32 TRUCKPARKING AND 18 MULTI-TRUCK STACK PARKING. 10. THERE IS NO OBSERVED EVIDENCE OF CURRENT EARTH MOVING WORK, BUILDING CONSTRUCTION OR BUILDING ADDITIONS AT THE PROPERTY. 11. THERE ARE NO KNOWN PROPOSED CHANGES IN RIGHT OF WAY LINES BY THE CONTROLLING JURISDICTION NOR EVIDENCE OF RECENT STREETOR SIDEWALK CONSTRUCTION REPAIRS AT THE PROPERTY. 12. THERE IS NO OBSERVED EVIDENCE OF USE OF THE PROPERTY AS A SOLID WASTE DUMP, SUMP OR SANITARY LANDFILL. TO: RYDER TRUCK RENTAL, INC., A FLORIDA CORPORATION ; AND FIRST AMERICAN TITLE INSURANCE COMPANY; THIS IS TO CERTIFY THAT THIS MAP OR PLAT AND THE SURVEY ONWHICH IT IS BASED WERE MADE IN ACCORDANCE WITH THE 2016 MINIMUM STANDARD DETAIL REQUIREMENTS FOR ALTA/NSPS LANDTITLE SURVEYS, JOINTLY ESTABLISHED AND ADOPTED BY ALTA AND NSPS, AND INCLUDES ITEMS 1, 2, 3, 4, 7(A1,C), 8, 9, 11, 13, 16, 18, 19 & 20, OF TABLE A, THEREOF. THE FIELD WORK WAS COMPLETED ON JULY5, 2019. MARK A. BORYS PLS# 46876 DATE GRAPHIC SCALE 0 1 INCH = FT. 40201010 20 N NE 1/4, NW 1/4, SEC. 36, T. 23 N., R. 04 E., W.M. BB A DA T E RE V I S I O N D R N JOB NO. DRAWN BY: CHECKED BY: DATE: SHEET 2 0 1 9 , B B A L A N D S U R V E Y I N G , I N C . , A L L R I G H T S R E S E R V E D C AL T A / N S P S L A N D T I T L E S U R V E Y NA V I X E N G I N E E R I N G 17 8 5 0 W V A L L E Y H W Y TU W I L A , W A 9 8 1 8 8 MAB RSN 19282 07/12/2019 2 OF 2 D 26.7126.8326.6 9 26.65 26.7326.6926.6426.54 26.93 27.14 27.35 27.45 27.28 27.09 26.9827.0 9 27.78 27.70 27.79 28.09 28.33 28.42 27.81 28.33 27.72 27.96 28.12 26.67 26.85 26.99 27.09 27.17 28.28 28.24 28.04 27.94 27. 6 7 28.41 28.12 27.40 27.23 27.94 28.72 28.48 28.18 27.12 27.09 26.93 26.9 4 26.96 27.4227.65 27. 25 26.7 2 26. 68 26.46 26.98 26.80 26.73 26.69 26.64 27.0 0 26.99 26.57 26.53 26.53 26.58 26.55 26.55 26.51 26.49 26.87 27. 2 2 27. 2 4 27.26 27. 1 8 26.7026.80 26.7126.63 27.77 27.7 3 27.62 27.49 27.31 27.12 27.87 27.94 27.76 27.68 27.65 27.60 28.0628.05 27.61 27.6827.77 27.93 27. 8 2 33.44 33.36 27.8429.04 30.80 28.65 28.35 28.80 29 . 68 28.77 28.07 26.8026.89 26.9727.24 26.88 26.63 26.52 26.29 25.96 26.00 25.57 25.46 25.4825.60 25 . 8 9 26.19 25.73 25.80 26.05 26.21 26.2026.44 26.45 25.95 25.7325.92 26.04 26.42 26.59 26.52 26.10 26.0 1 26.5 1 26.6 4 26.58 26.6626.7326.85 26.14 25.92 25.94 25.76 25.72 26.03 26.85 26.81 25.87 25.49 25. 5 5 25.30 25.46 25.60 27.14 27.36 27.17 26.36 25.55 25.45 25.32 25.49 25.54 26.48 27.28 25.7 5 25.13 25.30 26.98 27.0 7 27.1 1 26.5 9 27.4 427. 4 7 27.45 27 . 4 7 27. 5 0 27.69 27.65 27.91 27.6927.63 27.6 5 28.23 27.63 27.5127.46 27.5027.63 27.46 26.56 26.61 26.65 26.47 27.1427.13 27.1627.01 25 . 9 726.14 25.86 25.57 26.8727.19 27.1326.96 27.03 27.0 9 27.1427.1 6 27.30 27.31 27.33 26 . 9 2 26.8926.49 27.26 27.2127.15 26.48 26.8 5 26.87 26.82 26.8 526.90 26.8 7 26.82 26.78 26.79 26.8626.8126.36 26.93 26.4426.90 27.48 27.49 27.61 27. 8 4 28.06 28.18 28.26 28.36 28.45 28 . 2 728.40 28. 3 6 28.14 28.1028.2128.2928.4528.5028.5 9 28.8428.92 28 . 9 6 28.9029.02 28.90 28.9 0 28.82 28.78 28. 4 5 28.7728.7528.65 28.64 29. 05 28.9828.91 28.88 28.60 28.5 7 28.46 29.91 29.92 29.84 30.18 33 . 3 0 33.4 1 26. 1 0 26.08 26.05 25.95 25.79 25.78 25.71 25.67 25. 6 1 25.44 25.1 3 24.8624.74 25.77 27.57 27.5 9 27. 4 1 27.7628. 0 4 27.99 28.31 28. 3 3 28.34 28.27 28.18 25.54 26.40 27.1 5 27.18 27.03 27.03 26.7227.0 027.08 26. 5 5 26.88 26.60 27.1 0 27. 0 9 27.09 27.40 27.50 27.64 27. 4 3 27.59 27.38 26 .94 28.41 28.57 28.61 28.5 6 27.71 27. 8 1 28.08 27. 5 9 26.07 26.35 26.33 26.26 26.2 8 26.31 27. 6 4 28.01 27.8827.76 27.7127.7027.7927. 6 3 28.06 27.9 1 27.3027.05 27.0 0 27.30 27.4 5 27.5227.50 27.45 28.38 28.4 2 28. 5 2 28.55 28.57 28.55 28.5 6 28. 5 5 28.53 28.50 27.27 27. 5 6 27.30 27.47 27.28 27.40 27.22 27.45 27.49 27.20 27.15 27.46 27.3 727.08 27.2826.93 27.3 9 27.77 27.4 0 27.82 27.4327.88 27.9 3 27.44 27.4527.95 27. 9 4 27.47 27.46 27. 9 6 27.95 27. 4 6 27.22 27.6 5 27.6 327.21 27.20 27.5 327.24 27.25 27. 5 9 27.4627.95 28.0 0 27.45 27.46 27.89 27.8 8 27.45 27.44 26.98 27 . 3 1 26.58 26.53 26. 4 9 26.62 26.60 26. 5 3 33.31 33. 4 0 33.43 33 .48 33.47 26.66 26.90 27.48 26.82 25.51 25.48 26.64 26.48 25.3625.5025.87 25.79 25.65 26.78 26.87 26. 9 1 27.10 27.28 26.55 26.25 27.8 27.3 26.8 28 . 3 28.3 27. 8 28.4 28.127.9 28.6 32.2 32.3 32.6 32. 7 32. 5 30.4 32.6 31.7 31.7 32.6 27.53 27.60 27.6 8 26.98 26.82 26. 8 3 26. 9 6 26.91 26.82 26.80 26.89 26. 8 9 26 . 6 6 26.64 26.8 7 26. 8 126.7 6 26.87 26.96 26.99 27.00 27. 0 4 27. 0 7 27.04 26.89 28.3227.87 27.86 28.2928.3 1 27.8127.82 28.3 2 27.8727.9028.32 28 . 3 2 27. 8 4 28.32 28.0427.7327.6928.05 28.0 3 27.71 28.1 0 27.6927.6928.0 9 28.0927.71 27.6428.0028.0027.61 28. 0 3 27.58 27.6 1 28.1727.80 27.7928.20 28.2127.7 7 28.25 27.78 27.7928.2528.2427.80 27.72 27.8 6 27.83 27. 7 0 27.63 27.69 27.82 27.78 27.8 2 27 . 8 2 27.8 7 27.79 27.93 27.95 27.9027.90 27.64 27.69 27.53 27.5 5 27.53 27.52 32.7932. 80 32. 76 32.73 32.7 432.74 32.7932.75 27.56 27.58 27.75 27.79 26.38 27.68 27.94 27.6727.99 27.68 28.3927.85 28.40 27.83 27.8328.38 28 . 40 28.3927.83 27.79 28.37 28.39 27.80 27.84 27.6 26.8 26.826.7 26.8 26.8 26.8 26.8 26. 7 28.7 28.4 28.5 28.3 28.4 27.5 27.4 27.4 27.2 26.9 26.7 37.7 25.9 28.2 27.7 27.7 27.4 26.827.7 27.7 27. 6 27.529.0 30. 3 31. 3 32. 1 32. 6 32.8 32.7 32.7 32.6 32.5 31.4 33.4 33.3 33.1 32.7 32.7 33.2 32.8 33. 3 33.3 33.4 33 .5 30. 1 28.4 28. 0 29. 1 26. 2 26 . 1 24.5 24.2 24.9 24.7 25.5 24.9 25.0 25.1 26.7 26.3 27.1 27.3 27.1 27.4 27.0 30.6 27.6 27.8 27.827.8 27.8 27.9 27.7 27.93 27.83 27.70 26.80 26.7 2 26.78 26.70 26.60 26.53 26.68 26. 6 7 26.66 26.58 27.80 27.82 28.14 27.96 27.91 27.70 27. 74 27.5 6 27.51 27. 4 1 27 . 3 0 27.21 26. 9 7 28.05 28.37 28. 6 1 28.33 28.30 28.08 28.0728. 0 628.0 428.1228.2328.14 28.6328.6528.6628.60 28.09 28.04 27 . 6 2 27. 5 2 27.5227.4327.57 27 . 7 8 27 . 6 4 29.20 30 . 8 0 31.44 32.18 32.33 32.23 32.03 31.99 25.3025.31 25.04 27. 2 427.0 9 26.99 27.20 27.24 25.6725 . 6 4 27. 1 6 26.3526.24 26 . 3 2 26. 3 1 26.45 26.15 26.2 3 27.37 26.00 26.17 26.66 27.14 26.87 25.67 25.63 25. 5 9 24.30 27.41 27.88 27.94 27.4 4 27.33 27.48 27.73 26.11 26.05 26. 2 9 27.16 27.34 27.46 27.49 27.49 27 . 5 4 27.57 27.5 9 27. 6 7 27.66 27.73 27.28 27.29 27. 3 2 27 . 4 3 27.46 27.59 27.66 27.65 27.37 27.31 27.3 7 27.53 27.55 27.57 27.86 27.67 27.55 27.2 5 27. 2 3 27.1 7 27.20 29.1729.20 29.17 31.10 31. 1 3 31.27 31.2 3 32.6 7 32.57 32.33 32.3532.33 32.74 32. 08 32.36 33 . 2 2 33.2 8 32.86 32.90 32.84 32.76 32.7 5 32.85 30 . 5 0 30.48 33. 36 33.33 33.32 30.17 30.20 29.64 27.71 27.62 27.59 27. 19 27.49 27.58 27.60 27.53 27.65 27.57 27 . 4 4 27.4 6 27.45 27.49 27.47 27. 4 4 27.4227.4 6 27.46 27.50 27.5727.56 27. 5 7 27.57 27.6827.6 4 27.7 4 27.68 27. 5 4 26.74 26.89 26.79 26.78 26.70 26.53 26.61 26.5 8 26.59 26.52 26.5526.72 26.90 26.61 26.61 26.62 27.0926.99 27.00 26.8926.8526.72 26.77 26.8 1 26.87 26.92 27.2 0 27 . 2 9 27.32 27. 3 3 27.45 26.82 26.59 26.53 26.55 26.51 26.5 1 26.45 26.4 5 26.49 26.41 26.3 4 26.46 26.50 27.46 27.61 27.67 27.4 7 27. 5 8 27. 7 2 27. 7 9 27.88 28.0128.00 27.93 27.87 27.67 27. 6 5 27.7727.83 28.0028.0528.16 28.32 28.42 28.60 28.4628.52 28.3 2 28.50 28.50 28.4228.37 28.30 27.99 28.4128.4728.21 28.63 28.60 28.55 28.49 28.38 28.27 28.12 29. 3 5 29. 4 0 29. 0 0 29.29 30. 0 9 25.66 25.84 25 .86 25.79 25.7 7 25.63 32.84 32.92 25.70 25.83 25. 7 7 25.50 25.44 25.3 6 25.4 0 25.10 25.20 25.0 3 24. 6 5 24.3724.28 25.31 27.37 27.31 27.11 27. 3 5 27.67 27.93 27.92 27.92 27.86 27.78 25.01 25.93 26.68 26.7 1 26.59 26.58 26.2 9 26.57 26.65 26.41 26.19 26.47 26.70 26.73 26.59 26.38 26.22 26.66 26.59 26. 7 7 26.96 27.11 27.21 27.03 27.16 26.92 26.36 27.97 28.05 28.09 28.03 27.32 27.37 27.67 27.6 4 27.57 27.4527.38 27.3 5 27. 2 9 27.2 627.2827.2 7 27.86 27.91 25.9 25.8 26. 0 26.5 26.2 25.6 26.2 25.5 26.5 26. 4 26. 3 24.2 24.3 24.1 24.1 24.1 24.3 25. 7 26.0 26.1 25.8 26.3 26.8 22.022.1 22.2 22.5 22.1 26.4 26.6 25.826.026.6 25.7 26.0 23.6 22.4 21.9 22.1 22.8 22.6 23.6 21.9 21.8 21.9 22.323.9 24.9 24.4 24.3 24.3 24.3 24.3 28. 3 28.2 27.7 26.8 26. 7 26. 8 26.8 26.4 26.6 27.0 27.1 27.0 27.1 26.8 26.6 26.6 26.8 26.5 26.3 26.3 26.5 26. 1 26. 0 25. 6 26.5 26.526.226.0 26.0 26.3 25.6 24.624.8 24.9 25. 0 25.024.924.924.8 24 . 8 24.7 27.0 27.5 27.127.227.027.3 27.6 25.1 25.3 27.327.1 25.6 27.1 26.6 27.7 28.7 28.9 29.7 33. 2 24. 2 24 . 2 24.7 25.0 25.525.3 25.3 25.4 25. 8 26.1 26.5 25.6 25.6 33.4 25.3 25.3 25.4 24.9 25.2 25.3 25.3 25.3 25.5 25.1 25.1 25.7 26.6 24.3 21.0 25.2 25 .1 25.0 24.9 24.8 24.6 24.9 25.4 26.1 26.2 25.4 25.8 25.5 26.0 20.8 26.2 25.7 26.6 26.6 25 . 4 26. 5 27.1 26.5 26.2 26.4 27.4 26. 5 27.4 26. 0 26.2 26.5 27.6 26.7 25. 8 30.9 27.0 31.2 30. 5 32.4 31.3 32.4 32.4 26.0 26. 0 26.5 26.16 26.32 26.21 26.19 26.55 27.4 27.3 26.1 3 24 . 5 X X X X X X X X X X X X X X X X XXXX X X tel tel tel tel tel tel tel te l te l te l tel tel tel tel ue ue ue ue ue ue ue ue ue ue u e ue ue ue ue u e ue ue ue ue ue ue ue ueueue ue X san san san wm wm wm wm wm wm wm X X X X X 6" FIR 8" MAP 18" CW 22" CW 18" PINE8" PINE 8" PINE 16" PINE 18" PINE 10" PINE 10" PINE14" PINE20" CW 8",10" CW 12" CW18" CW 12" CW10" CW 10" CW16" CW 20" CW8" CW 12" CW 4" MAP 6" MAP 6" MAP 10" PINE 6" PINE 8" MAP 14" CW 10" PINE 8" PINE(DEAD) 6" PINE(DYING) 14" PINE 10" PINE(DYING) 8" PINE(DYING) 8",12"&24" CW 12" PINE(DYING)12" PINE 12" PINE14" PINE 6" PINE 12" PINE 8" PINE 6" PINE 8" BIR 14" FIR 22" PINE 26" PINE(DEAD)18" PINE20" PINE 28" PINE 16" PINE 22" PINE22" PINE18" PINE 18" PINE 18" FIR 18" OAK 24" CW 6" CW 12" CW 16" CW 10" MAP 8" PINE 10" PINE 10" PINE 10" PINE 8" PINE 8" PINE 12" PINE 12" PINE 14" PINE 6" CW 18" CW 6" PINE 10" PINE 8" PINE 12" PINE 16" PINE 8" PINE 10" PINE 8" PINE10" PINE 10" PINE 8" PINE 8" PINE 14" PINE 8" PINE 10" PINE 12" PINE 8" PINE 6" PINE 10" PINE 22" CW 12" CW 6" CW 8" CW 6" CW 6" PINE 8" PINE 12" CW 16" CW 8" PINE N 88°22'12" W 362.14' (362.36' DEED) N 0 1 ° 3 7 ' 4 8 " E 3 0 6 . 0 0 ' D E E D N 88°22'12" W 378.62' (378.39' DEED) (N LINE OF S 408' OF N 1/2 OF NW 1/4 OF SEC. 36-23-4) N 0 1 ° 2 7 ' 1 2 " W 3 0 6 . 4 4 ' D E E D N 88°22'12" W 573.59' 533.49' W V A L L E Y H W Y ga s ga s ga s ga s ga s ga s te l tel tel tel tel tel tel tel ue ue ue ue ue ue ue ue ELEC.TRANSFORMER ELEC.TRANSFORMER ga s g a s g a s g a s g a s CO N T A I N E R ELEC.TRANSFORMER st IE(W)=25.96'4"PVC IE(E)=25.94'4"PVC ga s ga s g a s IE(NE)=22.66' 12"CMP(END NOT FOUND) VENT oh oh oh oh oh oh oh oh oh ue ue ue ue ue ue wm wm wm CB T-1RIM=32.76'IE(N)=31.08' 8"IP CB T-1RIM=32.87'IE(N/S)=30.87' 8"IP CB T-1RIM=32.98'IE(S)=30.63' 8"IPIE(W)=29.73' 8"IP st st CB T-1RIM=27.87'IE(E)=23.37' 12"CPPIE(W)=23.17' 12"CPP CB T-1RIM=26.46'IE(E)=23.36' 12"CPP(END NOT FOUND) IE(W)=23.66' 12"CPP WATER LEVEL=23.71' SMHRIM=27.63'IE(E)=19.13' 8"PVCIE(SW)=19.33' 6"PVCIE(NW)=19.37' 6"PVC st st st san san s a n s a n san BUILDING VENT wm 22 2 6 26 26 26 28 28 28 ENTRY ENTRY ENTRY ENTRY ENTRYENTRYENTRYENTRY POND IE(SE)=21.32'12"CMP (UNDER WATER & MUD) POND ga s ga s ga s ga s ga s ga s ga s ga s ga s ga OLY M P I C P I P E L I N E ITEM 8-PARCEL B,40' JOINT INGRESS, EGRESS AND UTILIITY ESM'T, REC. NO. 8811180199 &ITEM 12- ACCESS AND UTULITY ESM'T, REC. NO. 8901101396 40' - 0 " ITEM 8 -PARCEL B,40' JOINT INGRESS, EGRESS AND UTILITIES ESM'T, REC. NO. 8811180199 &ITEM 12 - ACCESS AND UTILITIES ESM'T, REC. NO. 8901101396 40'- 0 " 49'-0" 10' SEWER ESM'T,REC. NO. 8811180199 & ITEM 9 - SEWER ESM'T, REC.NO. 8901101394 10 ' - 0 " ITEM 7- 15' PUBLIC UTILIITY ESM'T, REC NO. 8004280537 15 ' - 0 " ITEM 7- 15' PUBLIC UTILIITY ESM'T, REC NO. 8004280537 ITEM 16-10' SEWER ESM'T, REC. NO. 9106191617 10'-0" 18 ' - 0 " ITEM 7 - 15' PULBIC UTILITIES ESM'T, REC. NO. 8004280537 15'- 0 " ITEM 7 - 15' PULBIC UTILITIES ESM'T, REC. NO. 9102211113 15' - 0 " 10 ' - 0 " ITEM 3 - 15' PULBIC UTILITIES ESM'T, REC. NO.7110050390 15'-0" 26 P . S . P . & L . T R A N S M I S S I O N L I N E 15'-0" SMHRIM=27.08'IE(W)=15.18' 8"PVCIE(N)=14.82' 8"IPIE(S)=14.98' 8"IPIE(E)=14.57' 10"IP sa n sa n sa n sa n sa n sa n sa n sa n sa n SMHRIM=27.32'IE(N)=16.79' 8"IPIE(S)=16.89' 8"IPIE(W)=17.07' 8"IP san san san san san wm wm wm wm wm wm wm wm wm BUILDING HT=26.3' BUILDING HT=23.7' 27.25 27.27 FF = 2 7 . 7 1 ' FF=27.61' FF=27.75' FF = 2 7.81 ' FF = 2 7 . 7 9 ' FF = 2 7 . 8 0 ' FF = 2 7 . 7 2 ' FF = 2 7 . 8 6 ' FF = 2 7 . 7 1 ' FF = 2 7 . 8 6 ' FF = 2 7 . 9 2 ' FF=27.88' 26.76 26.7 26.2 26.4 RE=53.8 9 ' RE=45.39' RE=51.39' CO CO TR A F F I C F L O W TR A F F I C F L O W wm wm wm w m w m w m w m W W W W W EXISTING FIRE HYDRANT TO REMAIN EXISTING FIRE HYDRANT TO REMAIN EXISTING 12" GV IN MANHOLE EXISTING 12" GV IN MANHOLE. REF. STA 00+00 ON SHEET PP-1 SP-1 OV E R A L L S I T E P L A N SYMBOLS LEGEND PROPERTY LINE EXISTING CONCRETE TO REMAIN EXISTING TO REMAIN EXISTING PARKING STRIPE TO REMAIN EXISTING CONCRETE TO BE SAWCUT AND REMOVED EXISTING TO BE REMOVED PROPOSED CONCRETE PAVEMENT PROPOSED CONCRETE TANK PAD PROPOSED ABBREVIATIONS: AST ABOVEGROUND STORAGE TANK DEF DIESEL EXHAUST FLUID DW DOUBLE WALL FE FIRE EXTINGUISHER MAX MAXIMUM MIN MINIMUM O.C. ON CENTER TYP TYPICAL UST UNDERGROUND STORAGE TANK VIF VERIFY IN FIELD SCALE : 1/32" = 1'-0" OVERALL SITE PLAN SP-1 1 N Re v . # Da t e D e s c r i p t i o n 17 8 5 0 W E S T V A L L E Y H W Y CI V I L U P G R A D E S TU K W I L A , W A 9 8 1 8 8 Jo b # : 22 5 - 5 3 . 0 0 Sc a l e : Da t e : Dr a w n B y : Ch e c k e d B y : 02 / 1 3 / 2 0 2 5 AS S H O W N INFINITY ENGINEERING GROUP, LLC 1208 East Kennedy Boulevard Suite 230 Tampa, Florida 33602 [p]: 813.434.4770[f]: 813.445.4211 www.iegroup.net Date RICHARD HERNANDEZ, P.E. WA REG. NO. 50841 JP NS RY D E R T U K W I L A L C - 0 5 4 9 Cert. of Auth. No. 603-536-314 SITE DATA SITE ADDRESS 17850 WEST VALLEY HWY TUKWILA, WA 98188 PARCEL NUMBER 362304-9062 OWNER'S NAME RYDER TRUCK RENTAL INC OWNER'S ADDRESS PO BOX 025719 MIAMI, FLORIDA 33102 LEGAL DESCRIPTION PARCEL B OF CITY OF TUKWILA SHORT PLAT NO 88-3-SS RECORDING NO 8811180199 SD SHORT PLAT DAF -POR OF GOV LOT 2 & OF NE 1/4 OF NW 1/4 - BEG INTSN OF E MGN OF WEST VALLEY HWY SR 181 & A LN 480FT N OF & PLT MEAS AT R/A TO C/L OF S 180TH ST SW 43RD ST TH S 88-21-00 E TO W MGN OF PUGET SOUNDPOWER & LIGHT TRANS LN R/W PUGET SOUND ELECTRIC R/W THENCE N 01-26-00 W 306.44 FT M/L TAP OFINTSN WITH A LN 786 FT N OF & PLW C/L OF S 180TH ST TH N 88-21-00 W TO E MGN OF WEST VALLEY HWYSR 181 TH S 02-26-02 E 306.78 FT M/L TO POB WORK AREA D D D D D 99 26.5 7 26.5 3 26.5 3 26.5 8 26.55 26.5 5 26. 5 1 26.4 9 26.8 7 2 7 . 2 2 2 7 . 2 4 27.26 27 . 1 8 26.7 026.8 0 26.7 1 26.6 3 26.9 8 27 . 0 7 26. 5 9 2 727.4 5 2 7 . 4 7 27 . 5 0 27 6 5 27.9 1 27.63 27. 6 5 28.2 3 27.6 3 27.5 0 27.6 3 27.4 6 26.8 2 26. 8 5 26 . 9 0 26 . 8 7 26.8 2 26.7 8 26.79 26.8 626.8 1 26. 3 6 26.93 26.4 4 26.9 0 26 . 5 5 26 . 8 8 27 27.5 227.5 0 27.45 26 . 5 8 26.53 26.78 26.8 7 27.10 27.2 8 26. 5 5 26.25 26.9 8 26.8 2 2 6 . 8 3 26 . 9 6 26.9 1 26.82 26.8 0 26.89 2 6 . 8 9 2 6 . 6 6 26.64 2 6 . 8 7 26 . 8 1 26. 7 6 26.87 26.96 26.99 27.0 0 27 . 0 4 2 7 . 0 7 27.0 4 26.8 9 28.3 2 27.8 7 27.8 6 28.29 28 . 3 1 27.8127.8 2 28 . 3 2 27.8 7 27.9028.32 2 8 . 3 2 27 . 8 4 28.32 28.0 4 27.7 327.6928.0 5 28 . 0 3 27. 7 1 28. 1 0 27.6927.6928 . 0 9 28.0927.7 1 27.6428.00 28.00 27.61 28 . 0 3 27.58 27 . 6 1 28.17 27.80 27.7 9 28.2 0 28.21 27 . 7 7 28. 2 5 27. 7 8 27.79 28.2 528 . 2 4 27.8 0 27.7 2 27 . 8 6 27.8 3 27 . 7 0 27.63 27.69 27.8 2 27.78 27 . 8 2 2 7 . 8 2 27 . 8 7 27.79 27.9 3 27.9 5 27.9 0 27.90 27.64 27.69 27.53 27 . 5 5 27.53 27.52 27.6 8 27.9 4 27 . 6 7 27.9 9 27 . 6 8 28.3 9 27 . 8 5 28.4 0 27.83 27.8328.3 8 2 8 . 4 0 28.3927.83 27 . 7 9 28.3 7 28. 3 9 27.8 0 27.84 27.5 27.4 27.4 27.2 26.9 26.7 37.7 25.9 24.9 2 30 . 6 27.6 27.8 27.8 27 . 8 27.8 27.9 27.7 26.11 26.05 27.37 27.31 27 . 3 7 27.5 3 27.5 5 27.5 7 27.8 6 27.6 7 27.5 5 27.71 27.62 27.5 9 27 . 1 9 27.49 27.5 8 27.6 0 27.5 0 27.5 7 27.5 6 2 7 . 5 7 27. 5 7 27.68 26.74 26.8 9 26.79 26.78 26.70 26. 5 8 26.59 26.52 26.5 5 26.90 26.6 1 26.61 26.62 27.0 9 26.9 9 26.4 5 26 . 4 5 26.4 9 26 . 4 1 26 . 3 4 26.4 6 26.50 26.47 26.70 26.73 26.38 26. 2 2 25.9 25.8 2 6 . 0 26 . 5 26.2 25.6 26.2 25 . 5 24.2 24.3 24.1 24.1 23.6 23 2 6 . 1 2 6 . 0 25 . 6 26.5 26.526.226 . 0 26 . 0 26 . 3 25.6 2 5 . 1 26.0 25.7 26 . 0 26.2 26.5 27.6 26.1 6 26.3 2 26.21 26.1 9 26.55 27 . 4 27.3 26 . 1 3 2 4 . 5 XXXXXXXXXX X X X ue u e u e ue ue u e ue ue ue ue ue ue ue ue ue ue ue ue ue ue ue ue ue ue ue ue ue san san san san san san san san san san X X X X X X X X X (DYING) "&24" CW NE(DYING)12" PINE 12" PINE14" PINE 6" PINE 12" PINE 8" PINE 6" PINE 8" P10" PINE 8" PINE 6" PINE 10" PINE N 88°22'12" W 362.14' (362.36' DEED) CO N T A I N E R IE(W)=25.96' 4"PVC IE(E)=25.94' 4"PVC VENT wm san san san 28 2 8 ENTRY ENTRY ENTRY ENTRYENTRYENTRY stwm wm wm 10' SEWER ESM'T, REC. NO. 8811180199 & ITEM 9 - SEWER ESM'T, REC.NO. 8901101394 10 ' - 0 " ITEM 7 - 15' PULB 9102211113 15 ' - 0 " 10 ' - 0 " san san san san san san san san san san san san wm wm wm BUILDING HT=23.7' F F = 2 7 . 8 1 ' F F = 2 7 . 7 9 ' F F = 2 7 . 8 6 ' F F F = 2 7 . 9 2 ' FF=27.88' RE=45.39' RE=51.39' CO CO D D D wm wm wm wm wm wm wm wm wm wm w m w m w m w m w m w m w m w m w m w m w m w m w m w m w m w m w m EXISTING 12" WATER MAIN TO BE ABANDONED IN PLACE EXISTING 15'-0" UTILITY EASEMENT TO BE RELOCATED TO NEW WATER MAIN EXISTING 12" WATER MAIN TO REMAIN EXISTING 12" WATER MAIN TO BE ABANDONED IN PLACE EXISTING 15'-0" UTILITY EASEMENT TO BE RELOCATED TO NEW WATER MAIN 6' - 6 " 5' - 0 " 84'-7"5'-0"3'-11" 12 8 ' - 4 " ASPHALT TO BE REMOVED EXISTING 1" POWER LINE BURIED 24" BELOW GRADE EXISTING 12" WATER MAIN PORTION TO BE REMOVED AS SHOWN IN TRENCH EXISTING 8" SANITARY LINE TO REMAIN EXISTING 6" SANITARY LINE TO REMAIN PROPOSED PRODUCT PIPING LINE AND ELECTRICAL CONDUITS SUBMITTED BY SEPARATE PERMIT 00+00 01+00 02+00 EXISTING 12" GV IN MH SET AS STA 00+00 EXISTING FIRE HYDRANT TO REMAIN 3'-0" SP-2 DE M O L I T I O N P L A N SYMBOLS LEGEND PROPERTY LINE EXISTING CONCRETE TO REMAIN EXISTING TO REMAIN EXISTING PARKING STRIPE TO REMAIN EXISTING CONCRETE TO BE SAWCUT AND REMOVED EXISTING TO BE REMOVED EXISTING WATER MAIN TO BE ABANDONED IN PLACE EXISTING 15' UTILITY EASEMENT TO BE RELOCATED ABBREVIATIONS: AST ABOVEGROUND STORAGE TANK DEF DIESEL EXHAUST FLUID DW DOUBLE WALL FE FIRE EXTINGUISHER MAX MAXIMUM MIN MINIMUM O.C. ON CENTER TYP TYPICAL UST UNDERGROUND STORAGE TANK VIF VERIFY IN FIELD SCALE : 1/8" = 1'-0" DEMOLITION PLAN SP-2 1 Re v . # Da t e D e s c r i p t i o n 17 8 5 0 W E S T V A L L E Y H W Y CI V I L U P G R A D E S TU K W I L A , W A 9 8 1 8 8 Jo b # : 22 5 - 5 3 . 0 0 Sc a l e : Da t e : Dr a w n B y : Ch e c k e d B y : 02 / 1 3 / 2 0 2 5 AS S H O W N INFINITY ENGINEERING GROUP, LLC 1208 East Kennedy Boulevard Suite 230 Tampa, Florida 33602 [p]: 813.434.4770[f]: 813.445.4211 www.iegroup.net Date RICHARD HERNANDEZ, P.E. WA REG. NO. 50841 JP NS RY D E R T U K W I L A L C - 0 5 4 9 Cert. of Auth. No. 603-536-314 NOTE: CONTRACTOR TO FIELD VERIFY DEMO AREA AND BID ACCORDINGLY N wm MATCH LINE A-A'MATCH LINE A-A' DEMOLITION NOTES: 1. THE CONTRACTOR SHALL COORDINATE THE REMOVAL OF EXISTING UTILITIES WITH THE OWNER OF SAID UTILITY. THIS SHALL INCLUDE BUT NOT BE LIMITED TO WATER, SEWER, GAS, CABLE TV, POWER AND TELEPHONE. 2. THE CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES PRIOR TO DEMOLITION AND WILL BE RESPONSIBLE FOR THE DAMAGE OF ANY ON-SITE OR OFF-SITE UTILITIES THAT ARE NOT A PART OF THIS PROJECT OR ARE NOT IDENTIFIED TO BE REMOVED. 26.8 0 26.8 9 26.5 2 26.2 9 25.96 26. 0 0 25.5 7 25. 4 6 25.4 825.6 0 2 5 . 8 9 26. 1 9 25.73 25.80 26.0 5 26.2 1 26.2 0 26.6 6 26.7 3 26.8 5 26.1 4 25.9 2 25.94 25.7 6 25.7 2 26.0 3 26.8 5 26.8 1 25.8 7 25.4 9 25 . 5 5 25.3 0 25.4 6 25. 6 0 27.14 27.3 6 27.1 7 26.3 6 25. 5 5 25.4 5 25.3 2 25.4 9 25.5 4 26.4 8 27.2 8 25 . 7 5 25 . 1 3 25.3 0 27.63 27. 6 5 28.2 3 27.6 3 27.5 0 27.6 3 27.4 6 26.6 5 26.4 7 27.1 3 27.1627.0 1 26.14 25.8 6 25.5 7 26 . 1 0 26 . 0 8 26.05 25.9 5 25.79 25.78 25.71 25.67 25 . 6 1 25.4 4 26.0 7 26.35 26.33 26.2 6 26 . 2 8 26.31 27 . 4 5 27.5 227.5 0 27.45 25.7 9 25.65 27 . 7 0 27.63 27 . 8 2 2 7 . 8 2 27.79 27.75 27. 7 9 26.3 8 27.6 8 27.9 4 27 . 6 7 27.9 9 27 . 6 8 2 6 . 2 2 6 . 1 27.6 27.7 25.672 5 . 6 4 2 7 . 1 6 26.35 6.2 4 25.67 25.63 25 . 5 9 2 7 . 5 4 27. 5 7 27 . 5 9 27 . 6 7 27. 6 6 27.73 27.6 7 27.5 5 27.71 27.62 27.5 9 27 . 1 9 27.49 27.5 8 27.6 0 25.6 6 25.84 2 5 . 8 6 25.7 9 25.77 25.6 325.7 0 25.8 3 25 . 7 7 25.5 0 25. 4 4 25. 3 6 25. 4 0 25.10 25.2 0 25 . 0 3 25.0 25.525.4 25 . 8 26.1 26.5 25. 6 25.6 33.4 25.3 25.3 25.4 24.9 25.2 25 2 6 . 7 25 . 8 26 . 0 26 . 0 26.5 27 . 4 27.3 X X X X X X X X X X X X X X ueueueueueueueueueueue ue ue ue X X X wm wm wm wm wm wm wm wm wm X X " CW 16" CW 10" MAP 8" PINE 10" PINE 10" PINE 10" PINE 8" PINE 8" PINE 6" PINE 8" PINE N 88°22'12" W 378.62' (378.39' DEED) (N LINE OF S 408' OF N 1/2 OF NW 1/4 OF SEC. 36-23-4) XX VENT wm wm wm wm wm wm wm wm wm wm wm wm wm wm wm 26 ENTRY ENTRY ENTRY 18 ' - 0 " ITEM 7 - 15' PULBIC UTILITIES ESM'T, REC. NO. 8004280537 15 ' - 0 " 26 BUILDING HT=23.7' F F = 2 7 . 7 1 ' F F = 2 7 . 8 6 ' F F = 2 7 . 9 2 ' FF=27.88' TR A F F I C F L O W TR A F F I C F L O W wm wm wm wm wm wm wm wm wm EXISTING 12" WATER MAIN TO REMAIN EXISTING 12" WATER MAIN TO BE ABANDONED IN PLACE EXISTING 15'-0" UTILITY EASEMENT TO BE RELOCATED TO NEW WATER MAIN 33 ' - 1 " REMOVE EXISTING 12" 45 DEGREE BEND STA: 03+05 03+00 04+00 EXISTING FIRE HYDRANT TO REMAIN EXISTING 12" GV IN MH TO REMAIN SP-2.1 DE M O L I T I O N P L A N SYMBOLS LEGEND PROPERTY LINE EXISTING CONCRETE TO REMAIN EXISTING TO REMAIN EXISTING PARKING STRIPE TO REMAIN EXISTING CONCRETE TO BE SAWCUT AND REMOVED EXISTING TO BE REMOVED EXISTING WATER MAIN TO BE ABANDONED IN PLACE EXISTING 15' UTILITY EASEMENT TO BE RELOCATED ABBREVIATIONS: AST ABOVEGROUND STORAGE TANK DEF DIESEL EXHAUST FLUID DW DOUBLE WALL FE FIRE EXTINGUISHER MAX MAXIMUM MIN MINIMUM O.C. ON CENTER TYP TYPICAL UST UNDERGROUND STORAGE TANK VIF VERIFY IN FIELD SCALE : 1/8" = 1'-0" DEMOLITION PLAN SP-2.1 1 Re v . # Da t e D e s c r i p t i o n 17 8 5 0 W E S T V A L L E Y H W Y CI V I L U P G R A D E S TU K W I L A , W A 9 8 1 8 8 Jo b # : 22 5 - 5 3 . 0 0 Sc a l e : Da t e : Dr a w n B y : Ch e c k e d B y : 02 / 1 3 / 2 0 2 5 AS S H O W N INFINITY ENGINEERING GROUP, LLC 1208 East Kennedy Boulevard Suite 230 Tampa, Florida 33602 [p]: 813.434.4770[f]: 813.445.4211 www.iegroup.net Date RICHARD HERNANDEZ, P.E. WA REG. NO. 50841 JP NS RY D E R T U K W I L A L C - 0 5 4 9 Cert. of Auth. No. 603-536-314 NOTE: CONTRACTOR TO FIELD VERIFY DEMO AREA AND BID ACCORDINGLY N wm MATCH LINE A-A'MATCH LINE A-A' DEMOLITION NOTES: 1. THE CONTRACTOR SHALL COORDINATE THE REMOVAL OF EXISTING UTILITIES WITH THE OWNER OF SAID UTILITY. THIS SHALL INCLUDE BUT NOT BE LIMITED TO WATER, SEWER, GAS, CABLE TV, POWER AND TELEPHONE. 2. THE CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES PRIOR TO DEMOLITION AND WILL BE RESPONSIBLE FOR THE DAMAGE OF ANY ON-SITE OR OFF-SITE UTILITIES THAT ARE NOT A PART OF THIS PROJECT OR ARE NOT IDENTIFIED TO BE REMOVED. D D D D D 99 26.5 7 26.5 3 26.5 3 26.5 8 26.55 26.5 5 26. 5 1 26.4 9 26.8 7 2 7 . 2 2 2 7 . 2 4 27.26 27 . 1 8 26.7 026.8 0 26.7 1 26.6 3 26.9 8 27 . 0 7 26. 5 9 2 727.4 5 2 7 . 4 7 27 . 5 0 27 6 5 27.9 1 27.63 27. 6 5 28.2 3 27.6 3 27.5 0 27.6 3 27.4 6 26.8 2 26. 8 5 26 . 9 0 26 . 8 7 26.8 2 26.7 8 26.79 26.8 626.8 1 26. 3 6 26.93 26.4 4 26.9 0 26 . 5 5 26 . 8 8 27 27.5 227.5 0 27.45 26 . 5 8 26.53 26.78 26.8 7 27.10 27.2 8 26. 5 5 26.25 26.9 8 26.8 2 2 6 . 8 3 26 . 9 6 26.9 1 26.82 26.8 0 26.89 2 6 . 8 9 2 6 . 6 6 26.64 2 6 . 8 7 26 . 8 1 26. 7 6 26.87 26.96 26.99 27.0 0 27 . 0 4 2 7 . 0 7 27.0 4 26.8 9 28.3 2 27.8 7 27.8 6 28.29 28 . 3 1 27.8127.8 2 28 . 3 2 27.8 7 27.9028.32 2 8 . 3 2 27 . 8 4 28.32 28.0 4 27.7 327.6928.0 5 28 . 0 3 27. 7 1 28. 1 0 27.6927.6928 . 0 9 28.0927.7 1 27.6428.00 28.00 27.61 28 . 0 3 27.58 27 . 6 1 28.17 27.80 27.7 9 28.2 0 28.21 27 . 7 7 28. 2 5 27. 7 8 27.79 28.2 528 . 2 4 27.8 0 27.7 2 27 . 8 6 27.8 3 27 . 7 0 27.63 27.69 27.8 2 27.78 27 . 8 2 2 7 . 8 2 27 . 8 7 27.79 27.9 3 27.9 5 27.9 0 27.90 27.64 27.69 27.53 27 . 5 5 27.53 27.52 27.6 8 27.9 4 27 . 6 7 27.9 9 27 . 6 8 28.3 9 27 . 8 5 28.4 0 27.83 27.8328.3 8 2 8 . 4 0 28.3927.83 27 . 7 9 28.3 7 28. 3 9 27.8 0 27.84 27.5 27.4 27.4 27.2 26.9 26.7 37.7 25.9 24.9 2 30 . 6 27.6 27.8 27.8 27 . 8 27.8 27.9 27.7 26.11 26.05 27.37 27.31 27 . 3 7 27.5 3 27.5 5 27.5 7 27.8 6 27.6 7 27.5 5 27.71 27.62 27.5 9 27 . 1 9 27.49 27.5 8 27.6 0 27.5 0 27.5 7 27.5 6 2 7 . 5 7 27. 5 7 27.68 26.74 26.8 9 26.79 26.78 26.70 26. 5 8 26.59 26.52 26.5 5 26.90 26.6 1 26.61 26.62 27.0 9 26.9 9 26.4 5 26 . 4 5 26.4 9 26 . 4 1 26 . 3 4 26.4 6 26.50 26.47 26.70 26.73 26.38 26. 2 2 25.9 25.8 2 6 . 0 26 . 5 26.2 25.6 26.2 25 . 5 24.2 24.3 24.1 24.1 23.6 23 2 6 . 1 2 6 . 0 25 . 6 26.5 26.526.226 . 0 26 . 0 26 . 3 25.6 2 5 . 1 26.0 25.7 26 . 0 26.2 26.5 27.6 26.1 6 26.3 2 26.21 26.1 9 26.55 27 . 4 27.3 26 . 1 3 2 4 . 5 XXXXXXXXXX X X X ue u e u e ue ue u e ue ue ue ue ue ue ue ue ue ue ue ue ue ue ue ue ue ue ue ue ue san san san san san san san san san san X X X X X X X X X (DYING) "&24" CW NE(DYING)12" PINE 12" PINE14" PINE 6" PINE 12" PINE 8" PINE 6" PINE 8" P10" PINE 8" PINE 6" PINE 10" PINE N 88°22'12" W 362.14' (362.36' DEED) CO N T A I N E R IE(W)=25.96' 4"PVC IE(E)=25.94' 4"PVC VENT wm san san san 28 2 8 ENTRY ENTRY ENTRY ENTRYENTRYENTRY stwm wm wm 10' SEWER ESM'T, REC. NO. 8811180199 & ITEM 9 - SEWER ESM'T, REC.NO. 8901101394 10 ' - 0 " ITEM 7 - 15' PULB 9102211113 15 ' - 0 " 10 ' - 0 " san san san san san san san san san san san san wm wm wm BUILDING HT=23.7' F F = 2 7 . 8 1 ' F F = 2 7 . 7 9 ' F F = 2 7 . 8 6 ' F F F = 2 7 . 9 2 ' FF=27.88' RE=45.39' RE=51.39' CO CO D D D wm wm wm wm wm wm wm wm wm wm w m w m w m w m w m w m w m w m w m w m w m w m w m w m w m w m w m W W W W W W W W W W W W W W W W W W W W W W W W W EXISTING 12" WATER MAIN ABANDONED IN PLACE RELOCATED 15'-0" UTILITY EASEMENT CONNECTION POINT TO EXISTING 12" WATER MAIN TO REMAIN STA: 00+52 EXISTING 12" WATER MAIN ABANDONED IN PLACE 6' - 6 " 5' - 0 " 82'-0"5'-0"3'-11" 12 8 ' - 4 " NEW CONCRETE PAVEMENT 10'-0"5'-0" ± 64 LF NEW 12" D.I. WATER MAIN - BURY 54" BELOW GRADE (TYPICAL) NEW 12" GV (MJ x MJ) STA: 02+00 45 DEGREE BEND (MJ) W/ 90 DEGREE BEND (MJ) W/ CONCRETE BLOCKING STA: 01+37 CONFLICT POINT W/ 1" POWER LINE BURIED 24" BELOW GRADE PROVIDE 12" SEPARATION STA: 00+57 CONFLICT POINT W/ EXISTING 8" SANITARY LINE IE = 16.58 STA: 01+68 PROVIDE 12" SEPARATION CONFLICT POINT W/ PROPOSED PRODUCT PIPING AND ELECTRICAL POWER CONDUITS BY SEPARATE PERMIT IE = 25.50 STA: 01+70 AND PROPOSED INTRINSICALLY SAFE AND COMMUNICATION COUNDUITS IE = 24.50 STA: 01+70. PROVIDE 12" SEPARATION CONFLICT POINT W/ EXISTING 6" SANITARY LINE IE = 20.77 STA: 02+09 PROVIDE 12" SEPARATION 00+00 01+00 02+00 EXISTING 12" GV IN MH SET AS STA 00+00 EXISTING FIRE HYDRANT TO REMAIN ±85 LF NEW 12" D.I. WATER MAIN - BURY 54" BELOW GRADE (TYP) ± 62 LF NEW 12" D.I. WATER MAIN - BURY 54" BELOW GRADE (TYPICAL) 5'-7" SP-3 UT I L I T Y S I T E P L A N SYMBOLS LEGEND PROPERTY LINE EXISTING CONCRETE TO REMAIN EXISTING TO REMAIN EXISTING CURBING TO REMAIN EXISTING PARKING STRIPE TO REMAIN EXISTING CONCRETE TO BE SAWCUT AND REMOVED EXISTING TO BE REMOVED PROPOSED CONCRETE PAVEMENT PROPOSED CONCRETE TANK PAD PROPOSED PROPOSED 12" D.I. WATER MAIN PROPOSED EASEMENT EXISTING WATER MAIN (ABANDONED IN PLACE) ABBREVIATIONS: AST ABOVEGROUND STORAGE TANK DEF DIESEL EXHAUST FLUID DW DOUBLE WALL FE FIRE EXTINGUISHER MAX MAXIMUM MIN MINIMUM O.C. ON CENTER TYP TYPICAL UST UNDERGROUND STORAGE TANK VIF VERIFY IN FIELD SCALE : 1/8" = 1'-0" UTILITY SITE PLAN SP-3 1 N W wm Re v . # Da t e D e s c r i p t i o n 17 8 5 0 W E S T V A L L E Y H W Y CI V I L U P G R A D E S TU K W I L A , W A 9 8 1 8 8 Jo b # : 22 5 - 5 3 . 0 0 Sc a l e : Da t e : Dr a w n B y : Ch e c k e d B y : 02 / 1 3 / 2 0 2 5 AS S H O W N INFINITY ENGINEERING GROUP, LLC 1208 East Kennedy Boulevard Suite 230 Tampa, Florida 33602 [p]: 813.434.4770[f]: 813.445.4211 www.iegroup.net Date RICHARD HERNANDEZ, P.E. WA REG. NO. 50841 JP NS RY D E R T U K W I L A L C - 0 5 4 9 Cert. of Auth. No. 603-536-314 UTILITY NOTES: 1. CONTRACTOR TO VERIFY THE LOCATION OF ALL EXISTING UNDERGROUND UTILITIES WITHIN THE LIMITS OF CONSTRUCTION AND ADVISE THE ENGINEER OF RECORD OF ANY CONFLICTS IMMEDIATELY. 2. CONTRACTOR SHALL NOTIFY AND COORDINATE WATER SERVICE WITH LOCAL MUNICIPALITIES UTILITIES DEPARTMENT. 3. CONTRACTOR SHALL NOTIFY AND COORDINATE SEWER SERVICE WITH LOCAL MUNICIPALITIES UTILITIES DEPARTMENT. 4. CONTRACTOR TO COORDINATE INSTALLATION OF ELECTRICAL POWER SERVICE WITH LOCAL ELECTRIC COMPANY. 5. CONTRACTOR TO INSTALL PVC CONDUIT FOR TELEPHONE SERVICE (TO PROPERTY LINE) AND COORDINATE INSTALLATION OF SERVICE WITH TELEPHONE OPERATIONS. 6. SEE SURVEY FOR LOCATION OF OTHER EXISTING UTILITIES. 7. SEE CIVIL SPECIFICATIONS AND REFERENCE DRAWING SHEETS FOR ADDITIONAL UTILITY NOTES. 8. ALL CROSSINGS OF WATER AND SEWER LINES MUST MAINTAIN PROPER CLEARANCE (SEE CIVIL SPECIFICATIONS AND REFERENCE DRAWING SHEETS). 9. CONTRACTOR IS RESPONSIBLE FOR COMPLYING TO THE SPECIFICATIONS OF THE CITY/TOWNS STANDARD CONSTRUCTION AND UTILITY REQUIREMENTS. 10. TREES SHALL NOT BE PLANTED WITHIN 10 FEET FROM THE WATER MAIN. 11. ALL CLEANOUT TOP ELEVATION SHALL MATCH FINISH GRADE ELEVATIONS. MATCH LINE MATCH LINE STA: 02+60STA: 02+60 26.8 0 26.2 9 25.96 26. 0 0 25.5 7 25. 4 6 25.4 8 0 26.6 6 26.7 3 26.8 5 26.1 4 25.9 2 25.94 25.7 6 25.7 2 26.0 3 26.8 5 26.8 1 25.8 7 25.4 9 25 . 5 5 25.3 0 25.4 6 25. 6 0 27.14 27.3 6 27.1 7 26.3 6 25. 5 5 25.4 5 25.3 2 25.4 9 25.5 4 26.4 8 27.2 8 25 . 7 5 25 . 1 3 25.3 0 27.63 27. 6 5 28.2 3 27.6 3 27.5 0 27.6 3 27.4 6 26.6 5 26.4 7 27.1 3 27.1627.0 1 26.14 25.8 6 25.5 7 26 . 1 0 26 . 0 8 26.05 25.9 5 25.79 25.78 25.71 25.67 25 . 6 1 25.4 4 26.0 7 26.35 26.33 26.2 6 26 . 2 8 26.31 27 . 4 5 27.5 227.5 0 27.45 25.7 9 25.65 27 . 7 0 27.63 27 . 8 2 2 7 . 8 2 27.79 27.75 27. 7 9 26.3 8 27.6 8 27.9 4 27 . 6 7 27.9 9 27 . 6 8 2 6 . 2 2 6 . 1 27.6 27.7 25.67 25.67 25.63 25 . 5 9 27. 5 7 27 . 5 9 27 . 6 7 27. 6 6 27.73 27.6 7 27.5 5 27.71 27.62 27.5 9 27 . 1 9 27.49 27.5 8 27.6 0 25.6 6 25.84 2 5 . 8 6 25.7 9 25.77 25.6 325.7 0 25.8 3 25 . 7 7 25.5 0 25. 4 4 25. 3 6 25. 4 0 25.10 25.2 0 25 . 0 3 26.1 26.5 25. 6 25.6 33.4 25.3 25.3 25.4 24.9 25.2 25 2 6 . 7 25 . 8 26 . 0 26 . 0 26.5 27 . 4 27.3 X X X X X X X X X X X X X ueueueueueueueueueueue ue ue ue X X X wm wm wm wm wm wm wm wm wm 10" MAP 8" PINE 10" PINE 10" PINE 10" PINE 8" PINE 8" PINE 6" PINE 8" PINE N 88°22'12" W 378.62' (378.39' DEED) (N LINE OF S 408' OF N 1/2 OF NW 1/4 OF SEC. 36-23-4) XX VENT wm wm wm wm wm wm wm wm wm wm wm wm wm wm wm 26 ENTRY ENTRY ENTRY 18 ' - 0 " ITEM 7 - 15' PULBIC UTILITIES ESM'T, REC. NO. 8004280537 15 ' - 0 " 26 BUILDING HT=23.7' F F = 2 7 . 7 1 ' F F = 2 7 . 8 6 ' F F = 2 7 . 9 2 ' FF=27.88' TR A F F I C F L O W TR A F F I C F L O W wm wm wm wm wm wm wm wm wm W W W W W W W CONNECTION POINT TO EXISTING 12" WATER MAIN TO REMAIN STA: 02+94 EXISTING 12" WATER MAIN ABANDONED IN PLACE 33 ' - 1 " 45 DEGREE BEND (MJ) W/ CONCRETE BLOCKING STA: 02+62 03+00 04+00 EXISTING FIRE HYDRANT TO REMAIN EXISTING 12" GV IN MH TO REMAIN ± 62 LF NEW 12" D.I. WATER MAIN - BURY 54" BELOW GRADE (TYPICAL) ± 32 LF NEW 12" D.I. WATER MAIN - BURY 54" BELOW GRADE (TYPICAL) N W wm Re v . # Da t e D e s c r i p t i o n 17 8 5 0 W E S T V A L L E Y H W Y CI V I L U P G R A D E S TU K W I L A , W A 9 8 1 8 8 Jo b # : 22 5 - 5 3 . 0 0 Sc a l e : Da t e : Dr a w n B y : Ch e c k e d B y : 02 / 1 3 / 2 0 2 5 AS S H O W N INFINITY ENGINEERING GROUP, LLC 1208 East Kennedy Boulevard Suite 230 Tampa, Florida 33602 [p]: 813.434.4770[f]: 813.445.4211 www.iegroup.net Date RICHARD HERNANDEZ, P.E. WA REG. NO. 50841 JP NS RY D E R T U K W I L A L C - 0 5 4 9 Cert. of Auth. No. 603-536-314 SP-3.1 UT I L I T Y S I T E P L A N SYMBOLS LEGEND PROPERTY LINE EXISTING CONCRETE TO REMAIN EXISTING TO REMAIN EXISTING CURBING TO REMAIN EXISTING PARKING STRIPE TO REMAIN EXISTING CONCRETE TO BE SAWCUT AND REMOVED EXISTING TO BE REMOVED PROPOSED CONCRETE PAVEMENT PROPOSED CONCRETE TANK PAD PROPOSED PROPOSED 12" D.I. WATER MAIN PROPOSED EASEMENT EXISTING WATER MAIN (ABANDONED IN PLACE) ABBREVIATIONS: AST ABOVEGROUND STORAGE TANK DEF DIESEL EXHAUST FLUID DW DOUBLE WALL FE FIRE EXTINGUISHER MAX MAXIMUM MIN MINIMUM O.C. ON CENTER TYP TYPICAL UST UNDERGROUND STORAGE TANK VIF VERIFY IN FIELD SCALE : 1/8" = 1'-0" UTILITY SITE PLAN SP-3.1 1 MATCH LINE MATCH LINE UTILITY NOTES: 1. CONTRACTOR TO VERIFY THE LOCATION OF ALL EXISTING UNDERGROUND UTILITIES WITHIN THE LIMITS OF CONSTRUCTION AND ADVISE THE ENGINEER OF RECORD OF ANY CONFLICTS IMMEDIATELY. 2. CONTRACTOR SHALL NOTIFY AND COORDINATE WATER SERVICE WITH LOCAL MUNICIPALITIES UTILITIES DEPARTMENT. 3. CONTRACTOR SHALL NOTIFY AND COORDINATE SEWER SERVICE WITH LOCAL MUNICIPALITIES UTILITIES DEPARTMENT. 4. CONTRACTOR TO COORDINATE INSTALLATION OF ELECTRICAL POWER SERVICE WITH LOCAL ELECTRIC COMPANY. 5. CONTRACTOR TO INSTALL PVC CONDUIT FOR TELEPHONE SERVICE (TO PROPERTY LINE) AND COORDINATE INSTALLATION OF SERVICE WITH TELEPHONE OPERATIONS. 6. SEE SURVEY FOR LOCATION OF OTHER EXISTING UTILITIES. 7. SEE CIVIL SPECIFICATIONS AND REFERENCE DRAWING SHEETS FOR ADDITIONAL UTILITY NOTES. 8. ALL CROSSINGS OF WATER AND SEWER LINES MUST MAINTAIN PROPER CLEARANCE (SEE CIVIL SPECIFICATIONS AND REFERENCE DRAWING SHEETS). 9. CONTRACTOR IS RESPONSIBLE FOR COMPLYING TO THE SPECIFICATIONS OF THE CITY/TOWNS STANDARD CONSTRUCTION AND UTILITY REQUIREMENTS. 10. TREES SHALL NOT BE PLANTED WITHIN 10 FEET FROM THE WATER MAIN. 11. ALL CLEANOUT TOP ELEVATION SHALL MATCH FINISH GRADE ELEVATIONS. STA: 02+60STA: 02+60 99 26.5 7 26.5 3 26.5 3 26.5 8 26.55 26.5 5 26. 5 1 26.4 9 26.8 7 2 7 . 2 2 2 7 . 2 4 27.26 27 . 1 8 26.7 026.8 0 26.7 1 26.6 3 0 6.85 26.8 5 26.8 1 27.14 27.3 6 27.1 7 27.2 8 26.9 8 27 . 0 7 26. 5 9 2 727.4 5 2 7 . 4 7 27 . 5 0 27 6 5 27.9 1 27.63 27. 6 5 28.2 3 27.6 3 27.5 0 27.6 3 27.4 6 27.1 3 27.1627.0 1 27 . 4 5 27.5 227.5 0 27.45 26 . 5 8 26.53 26.78 26.8 7 27.10 27.2 8 26. 5 5 26.9 8 26.8 2 2 6 . 8 3 26 . 9 6 26.9 1 26.82 26.8 0 26.89 2 6 . 8 9 2 6 . 6 6 26.64 26 . 8 7 26 . 8 1 26. 7 6 26.87 26.96 26.99 27.0 0 27 . 0 4 27 . 0 7 27.0 4 28.3 2 27.8 7 27.8 6 28.29 28 . 3 1 27.8127.8 2 28 . 3 2 27.8 7 27.9028.32 2 8 . 3 2 27 . 8 4 28.32 28.0 4 27.7 327.6928.0 5 28 . 0 3 27. 7 1 28. 1 0 27.6927.6928 . 0 9 28.0927.7 1 27.6428.00 28.00 27.61 28 . 0 3 27.58 27 . 6 1 28.17 27.80 27.7 9 28.2 0 28.21 27 . 7 7 28. 2 5 27. 7 8 27.79 28.2 528 . 2 4 27.8 0 27.7 2 27 . 8 6 27.8 3 27 . 7 0 27.63 27.69 27.8 2 27.78 27 . 8 2 2 7 . 8 2 27 . 8 7 27.79 27.9 3 27.9 5 27.9 0 27.90 27.64 27.69 27.53 27 . 5 5 27.53 27.52 27.75 27. 7 9 27.6 8 27.9 4 27 . 6 7 27.9 9 27 . 6 8 28.3 9 27 . 8 5 28.4 0 27.83 27.8328.3 8 2 8 . 4 0 28.3927.83 27 . 7 9 28.3 7 28. 3 9 27.8 0 27.84 27.5 27.4 27.4 27.2 26.9 26.7 27.6 27.8 27.8 27 . 8 27.8 27.9 27.7 27. 5 7 27 . 5 9 27 . 6 7 27. 6 6 27.73 27.37 27.31 27 . 3 7 27.5 3 27.5 5 27.5 7 27.8 6 27.6 7 27.5 5 27.71 27.62 27.5 9 27 . 1 9 27.49 27.5 8 27.6 0 27.5 0 27.5 7 27.5 6 27 . 5 7 27. 5 7 27.68 26.5 8 26.90 26.6 1 26.61 26.62 27.0 9 26.9 9 26.47 26.70 26.73 26. 2 2 26.5 27.6 26 . 7 26.1 6 26.3 2 26.21 26.1 9 27 . 4 27.3 CO N T A I N E R IE(W)=25.96' 4"PVC IE(E)=25.94' 4"PVC VENT 28 2 8 ENTRY ENTRY ENTRY ENTRYENTRYENTRY BUILDING HT=23.7' F F = 2 7 . 8 1 ' F F = 2 7 . 7 9 ' F F = 2 7 . 8 6 ' F F = 2 7 . 7 1 ' F F = 2 7 . 8 6 ' F F = 2 7 . 9 2 ' FF=27.88' RE=45.39' RE=51.39' CO CO TR A F F I C F L O W TR A F F I C F L O W 26.50MEG 26.50MEG 26.55 MEG 26.55MEG 27.45MEG 27.45 MEG 26.70MEG 26.70 MEG SP-4 GR A D I N G P L A N SYMBOLS LEGEND PROPERTY LINE EXISTING CONCRETE TO REMAIN EXISTING TO REMAIN EXISTING PARKING STRIPE TO REMAIN EXISTING CONCRETE TO BE SAWCUT AND REMOVED EXISTING TO BE REMOVED PROPOSED CONCRETE PAVEMENT PROPOSED CONCRETE TANK PAD PROPOSED EXISTING GRADE PROPOSED EDGE OF PAVEMENT ELEVATION (FT) PROPOSED TOP OF CONCRETE / EDGE OF PAVEMENT ELEVATION (FT) PROPOSED SURFACE FLOW PROPOSED UNEVEN TRANSITION PROPOSED EVEN TRANSITION ABBREVIATIONS: AST ABOVEGROUND STORAGE TANK DEF DIESEL EXHAUST FLUID DW DOUBLE WALL FE FIRE EXTINGUISHER FFE FINISHED FLOOR ELEVATION HP HIGH POINT MAX MAXIMUM MEG MATCH EXISTING GRADE MIN MINIMUM O.C. ON CENTER TOC TOP OF CURB TOS TOP OF SLAB TYP TYPICAL UST UNDERGROUND STORAGE TANK VIF VERIFY IN FIELD SCALE : 1/8" = 1'-0" GRADING PLAN SP-4 1 Re v . # Da t e D e s c r i p t i o n 17 8 5 0 W E S T V A L L E Y H W Y CI V I L U P G R A D E S TU K W I L A , W A 9 8 1 8 8 Jo b # : 22 5 - 5 3 . 0 0 Sc a l e : Da t e : Dr a w n B y : Ch e c k e d B y : 02 / 1 3 / 2 0 2 5 AS S H O W N INFINITY ENGINEERING GROUP, LLC 1208 East Kennedy Boulevard Suite 230 Tampa, Florida 33602 [p]: 813.434.4770[f]: 813.445.4211 www.iegroup.net Date RICHARD HERNANDEZ, P.E. WA REG. NO. 50841 JP NS RY D E R T U K W I L A L C - 0 5 4 9 Cert. of Auth. No. 603-536-314 CONSTRUCTION NOTE: CONTRACTOR TO VERIFY ALL UNDERGROUND UTILITIES BEFORECONSTRUCTION BEGINS. NOTIFY THE EOR IN CASE OF ANY DISCREPANCY. CONTRACTOR TO ENSURE THE EXISTING DRAINAGE PATTERN FOR THE SITESHALL BE MAINTAINED AT ALL TIMES N 00.00 00.00 00.00 D CONC. SLAB1/4" D CS-1 CI V I L S I T E D E T A I L S SCALE : 1/2" = 1'-0" CONCRETE DRIVE CS-1 1 SCALE : 1/2" = 1'-0" RESERVED CS-1 5 SCALE : 1/2" = 1'-0" RESERVED CS-1 4 SCALE : 1/2" = 1'-0" RESERVED CS-1 3 SCALE : 1/2" = 1'-0" RESERVED CS-1 6 SCALE : 1/2" = 1'-0" RESERVED CS-1 7 SCALE : 1/2" = 1'-0" RESERVED CS-1 8 SCALE : 1/2" = 1'-0" RESERVED CS-1 11 SCALE : 1/2" = 1'-0" SECTION AT SAWCUT CS-1 2 SCALE : 1/2" = 1'-0" RESERVED CS-1 10 SCALE : 1/2" = 1'-0" RESERVED CS-1 12 Re v . # Da t e D e s c r i p t i o n 17 8 5 0 W E S T V A L L E Y H W Y CI V I L U P G R A D E S TU K W I L A , W A 9 8 1 8 8 Jo b # : 22 5 - 5 3 . 0 0 Sc a l e : Da t e : Dr a w n B y : Ch e c k e d B y : 02 / 1 3 / 2 0 2 5 AS S H O W N INFINITY ENGINEERING GROUP, LLC 1208 East Kennedy Boulevard Suite 230 Tampa, Florida 33602 [p]: 813.434.4770[f]: 813.445.4211 www.iegroup.net Date RICHARD HERNANDEZ, P.E. WA REG. NO. 50841 JP NS RY D E R T U K W I L A L C - 0 5 4 9 Cert. of Auth. No. 603-536-314 SCALE : 1/2" = 1'-0" RESERVED CS-1 9 6" EXISTING CONCRETE PAVEMENT NEW 6" MIN. 18" CONTROL JOINT FORM, PLACE, AND BROOM FINISH NEW 4,000 PSI CONCRETE SLAB #5 REBAR DOWEL @ 24" O.C. (ONLY REQUIRED WHEN ADJACENT WITH EXISTING CONCRETE PAVEMENT) 6"x6" 6 / 6 W.W.M. OR FIBERMESH WELL COMPACTED APPROVED BACKFILL MATERIAL NOTE: 1. CONTROL JOINT REQUIRED FOR SLAB SIZE MORE THAN 12'-0". 2. CONTROL JOINT (1/4" WIDTH x 2" DEEP) WITHIN 12 HOURS OF POUR DT-1 DE T A I L S Re v . # Da t e D e s c r i p t i o n 17 8 5 0 W E S T V A L L E Y H W Y CI V I L U P G R A D E S TU K W I L A , W A 9 8 1 8 8 Jo b # : 22 5 - 5 3 . 0 0 Sc a l e : Da t e : Dr a w n B y : Ch e c k e d B y : 02 / 1 3 / 2 0 2 5 AS S H O W N INFINITY ENGINEERING GROUP, LLC 1208 East Kennedy Boulevard Suite 230 Tampa, Florida 33602 [p]: 813.434.4770[f]: 813.445.4211 www.iegroup.net Date RICHARD HERNANDEZ, P.E. WA REG. NO. 50841 JP NS RY D E R T U K W I L A L C - 0 5 4 9 Cert. of Auth. No. 603-536-314 DT-2 DE T A I L S Re v . # Da t e D e s c r i p t i o n 17 8 5 0 W E S T V A L L E Y H W Y CI V I L U P G R A D E S TU K W I L A , W A 9 8 1 8 8 Jo b # : 22 5 - 5 3 . 0 0 Sc a l e : Da t e : Dr a w n B y : Ch e c k e d B y : 02 / 1 3 / 2 0 2 5 AS S H O W N INFINITY ENGINEERING GROUP, LLC 1208 East Kennedy Boulevard Suite 230 Tampa, Florida 33602 [p]: 813.434.4770[f]: 813.445.4211 www.iegroup.net Date RICHARD HERNANDEZ, P.E. WA REG. NO. 50841 JP NS RY D E R T U K W I L A L C - 0 5 4 9 Cert. of Auth. No. 603-536-314 00+00 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 00+50 01+00 01+50 02+00 02+50 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 03+00 EXISTING GRADE EXISTING FIRE HYDRANT STA: 00+11 -00+50 03+50 04+00 04+50 05+00 EXISTING 12" GV IN MH SET AS STATION 00+00 TOP ELEV = 22.25 STA: 00+00 EXISTING 12" WATER MAIN POINT OF CONNECTION TO EXISTING WATER MAIN TOP ELEV = 22.00 STA: 00+52 EXISTING 12" WATER MAIN ± 85 LF NEW 12" D.I. WATER MAIN - BURY 54" BELOW GRADE (TYP) EXISTING 1" POWER LINE BURIED 24" BELOW GRADE STA: 00+57 90 DEG. BEND (MJ) W/ CONC STA: 01+37 EXISTING FIRE HYDRANT STA: 04+01 45 DEG. BEND (MJ) W/ CONC BLOCKING STA: 02+62 POINT OF CONNECTION TO EXISTING WATER MAIN TOP ELEV = 22.00 STA: 02+94 EXISTING 12" GV IN MH TOP ELEV = 22.00 STA: 04+33 EXISTING 12" WATER MAIN PROPOSED PRODUCT PIPING AND ELECTRICAL POWER CONDUITS BY SEPARATE PERMIT TOP ELEV = 25.50 STA: 01+70 EXISTING 8" SANITARY LINE TOP ELEV = 16.58 STA: 01+68 EXISTING 6" SANITARY LINE TOP ELEV = 20.77 STA: 02+09 NEW 12" GV (MJ x MJ) STA: 02+00 EXISTING 12" WATER MAIN EXISTING GRADE EXISTING GRADE EXISTING GRADE ± 64 LF NEW 12" D.I. WATER MAIN - BURY 54" BELOW GRADE (TYP) ± 62 LF NEW 12" D.I. WATER MAIN - BURY 54" BELOW GRADE (TYP) ± 32 LF NEW 12" D.I. WATER MAIN - BURY 54" BELOW GRADE (TYP) MI N 5 4 " C O V E R MA T C H L I N E MA T C H L I N E ST A : 0 2 + 6 0 ST A : 0 2 + 6 0 PROPOSED INTRINSICALLY SAFE AND COMMUNICATION CONDUITS BY SEPARATE PERMIT TOP ELEV = 24.50 STA: 01+70 PP-1 PL A N A N D P R O F I L E Re v . # Da t e D e s c r i p t i o n 17 8 5 0 W E S T V A L L E Y H W Y CI V I L U P G R A D E S TU K W I L A , W A 9 8 1 8 8 Jo b # : 22 5 - 5 3 . 0 0 Sc a l e : Da t e : Dr a w n B y : Ch e c k e d B y : 02 / 1 3 / 2 0 2 5 AS S H O W N INFINITY ENGINEERING GROUP, LLC 1208 East Kennedy Boulevard Suite 230 Tampa, Florida 33602 [p]: 813.434.4770[f]: 813.445.4211 www.iegroup.net Date RICHARD HERNANDEZ, P.E. WA REG. NO. 50841 JP NS RY D E R T U K W I L A L C - 0 5 4 9 Cert. of Auth. No. 603-536-314 PROFILE - WATER LINE SCALE: 1" = 20' V SCALE: 1" = 2'SCALE: 1" = 0' 20' 20' 40'