Loading...
HomeMy WebLinkAboutP_Construction_Documents_20250528_V1WH WH DN DN DN WH MECH. RM (E) OFFICE (E) UTILITY ROOM (E) SOCIAL HALL(E) BATH (E) SOCIAL HALL (E) STORAGE DEMO EXIST STAIRS DEMO EXIST SHOWER 7 A1.1 (E) OFFICE (E) UTILITY ROOM (E) SOCIAL HALL (E) BATH (E) SOCIAL HALL (E) STORAGE 45' - 10" 23' - 4" 27 ' - 1 1 " 11 ' - 2 " RA M P D N MECH RM 6 A1.1 1' - 3" 3' - 0 " A1.0 6 7 A1.1 (E) WORSHIP HALL (E) OFFICE (E) TOILET(E) WORSHIP AREA (E) MECH (E) DECK (E) PORCH DN DN 7 A1.1 (EXPANDED) WORSHIP HALL RAMP DN RA M P DN 45' - 10" 23' - 4" 27 ' - 1 1 " . 11 ' - 2 " 60 6 8 TOILET 30 68 12' - 6 3/4"7' - 10 1/2" 6' - 7 3 / 4 " 6 A1.1 (E) DECK (E ) P O R C H DN DN DS DS DS DS DS DS 2 A1.0 5 60 60 (30)60 60 (30)60 60 (30) 60 60 (30)60 60 (30)60 60 (30) 60 60 (30) 60 6 0 ( 3 0 ) 60 6 0 ( 3 0 ) 60 60 (30) (N) FTG BELOW 19' - 3"7' - 9"7' - 5"6' - 4" 5' - 3"7' - 9"7' - 5"6' - 4" 7' - 5 1/2"7' - 5 1/2" 6' - 7 1 / 2 " 7' - 8 " 7' - 0 " 7' - 3 " 5' - 4 " NEW EXTERIOR ADDITION FILL-IN FLOOR TO MATCH EXISTING FILL-IN FLOOR TO MATCH EXISTING 7 A1.1 DS DS DS DS DS DS ROOF VENT CALCULATION: 1074 SF / 150 = 7.16 7.16 X 144 = 1032 1032 / 2 = 516 SQ. IN. VENTS: 3" X 12" (36 SQ. IN.) 516 / 36 = 14 OR VENTS ROOF DRAINAGE: AREA 1074 SF DRAINAGE REQ'D: 1047 SF X .0028 = 3.0 SQ IN DRAINAGE PROVIDED 6 SQ IN [1 (2x3}] DS ROOF DRAINAGE: AREA 1074 SF DRAINAGE REQ'D: 1047 SF X .0028 = 3.0 SQ IN DRAINAGE PROVIDED 6 SQ IN [1 (2x3}] DS ROOF DRAINAGE EA SIDE: AREA 170 SF DRAINAGE REQ'D: 170 SF X .0028 = 0.5 SQ IN DRAINAGE PROVIDED 6 SQ IN [1 (2x3}] DS 3" X 12" ROOF VENT, TYP OF 14 7 A1.1 TOILET 30 68 7' - 10 1/2" 6' - 7 3 / 4 " 2 A1.1 10TOILET 2 -N A1.1 11 TO I L E T 2 - E 30" 48" 5'-4" DIA. A1.1 (E) BATH 8. TO I L E T 1 - W 9.TOILET 1-N 5' - 10 1/2" 11 ' - 9 1 / 2 " 60" 56" 30 6 8 5'-4" DIA. 2 48" 30" Scale Date Drawn By Checked By Project Number NO.DATEDESCRIPTION BO D E T E M P L E RE N O V A T I O N / A D D I T I O N 11 4 1 0 S E P E T R O V I T S K Y R D RE N T O N , W A 9 8 0 5 5 GESTOSO DESIGN & DRAFTING SERVICES 22420 127TH AVE SE KENT WA 98031 (253) 709-7543 E: OSCAR. GESTOSO @GMAIL.COM As indicated 12 / 1 7 / 2 0 2 4 1 1 : 3 6 : 5 3 A M A1.0 FLR PLANS/ ENERGY NOTES/ PLAN KEY TTT OVG 12/04/2024 2024.01 1/8" = 1'-0"1 MAIN LEVEL - EXIST/DEMO 1/8" = 1'-0"2 MAIN LEVEL - PROPOSED 1/8" = 1'-0"3 UPPER LEVEL - EXIST/DEMO 1/8" = 1'-0"4 UPPER LEVEL - PROPOSED 1/8" = 1'-0"7 TOP OF ROOF MAIN FLOOR PLAN NOTES 1/2" = 1'-0"5 ENLARGED TOILET PLAN 2 1/2" = 1'-0"6 ENLARGED TOILET PLAN 1 MAIN LEVEL - EXIST/DEMO 0' -0" UPPER LEVEL - EXIST/DEMO 9' -2" TOP OF ROOF 31' -7" T.O. PLATE 19' -10 1/2" FACTORY DIRECT STONE ROOF TILES ON ROOF CONSTRUCTION (SEE TYP ROOF CONSTRUCTION NOTES THIS SHT) NEW ROOFS ADDITION7 A1.1 MAIN LEVEL - EXIST/DEMO 0' -0" UPPER LEVEL - EXIST/DEMO 9' -2" TOP OF ROOF 31' -7" 6 A1.1 T.O. PLATE 19' -10 1/2" FACTORY DIRECT STONE ROOF TILES ON ROOF CONSTRUCTION (SEE TYP ROOF CONSTRUCTION NOTES THIS SHT) NEW ROOF ADDITIONS NEW WALL ADDITION R 1 9' - 6 1 1 /3 2 "R 19' - 6 11/32" A1.1 12 MAIN LEVEL - EXIST/DEMO 0' -0" UPPER LEVEL - EXIST/DEMO 9' -2" TOP OF ROOF 31' -7" T.O. PLATE 19' -10 1/2" NEW ROOF ADDITIONS NEW WALL ADDITION A1.1 13 7 A1.1 MAIN LEVEL - EXIST/DEMO 0' -0" UPPER LEVEL - EXIST/DEMO 9' -2" TOP OF ROOF 31' -7" 6 A1.1 T.O. PLATE 19' -10 1/2" FACTORY DIRECT STONE ROOF TILES ON ROOF CONSTRUCTION (SEE TYP ROOF CONSTRUCTION NOTES THIS SHT) NEW ROOFS ADDITION MAIN LEVEL - EXIST/DEMO 0' -0" UPPER LEVEL - EXIST/DEMO 9' -2" TOP OF ROOF 31' -7" 6 A1.1 (EXPANDED) WORSHIP HALL (E) SOCIAL HALL ATTIC T.O. PLATE 19' -10 1/2" SCISSOR TRUSS R-49 BATT INSULATION R-21 BATT INSUL.R-21 BATT INSUL. MAIN LEVEL - EXIST/DEMO 0' -0" UPPER LEVEL - EXIST/DEMO 9' -2" TOP OF ROOF 31' -7" (EXPANDED) WORSHIP HALL (E) SOCIAL HALL (E) OFFICE T.O. PLATE 19' -10 1/2"3" / 1'-0" R-60 BATT INSULATION 5/8" GWB CLG ON SCISSOR TRUSSES @ 24" O.C. BY TRUSS MFG. FACTORY DIRECT STONE ROOF TILES ON ROOF CONSTRUCTION (SEE TYP ROOF CONSTRUCTION NOTES THIS SHT) 3" X 12" VENTILATION SLOT (SEE ROOF PLAN) R 47' - 5 7/8" R 4 7' - 5 7 / 8 " R 47' -6" R-21 BATT INSUL. IN ADDED WALL CONTINUOUS ROOF EDGE ROLL 7 A1.1 3' - 0 " 1' - 5 " 3' - 4 " 2' - 1 0 " 3' - 0"6". 1' - 5 " 3' - 0 " 1' - 6 " 3' - 3 " 1' - 0"3' - 6" 3' - 3" 1' - 5 " 3' - 0 " 1' - 6 " 3' - 3 " 3' - 6"1' - 0" 3' - 3" 2' - 1 0 " 3' - 4 " 1' - 5 " 3' - 0 " R 1' - 3" R 0 ' - 9 1 7 /3 2 " R 1 ' - 6 1 / 2 " R 0' - 9 3 /4 "R 0' - 5 27/32" R 1' - 8" R 1 9' - 6 1 1 / 3 2 " 5/8" GWB CLG ON SCISSOR TRUSSES @ 24" O.C. BY TRUSS MFG. FACTORY DIRECT STONE ROOF TILES ON ROOF CONSTRUCTION (SEE TYP ROOF CONSTRUCTION NOTES THIS SHT) R-60 BATT INSULATION IN CURVED ROOF FRAMING 3" X 12" VENTILATION SLOT (SEE ROOF PLAN) CONTINUOUS ROOF EDGE ROLL Scale Date Drawn By Checked By Project Number NO.DATEDESCRIPTION BO D E T E M P L E RE N O V A T I O N / A D D I T I O N 11 4 1 0 S E P E T R O V I T S K Y R D RE N T O N , W A 9 8 0 5 5 GESTOSO DESIGN & DRAFTING SERVICES 22420 127TH AVE SE KENT WA 98031 (253) 709-7543 E: OSCAR. GESTOSO @GMAIL.COM As indicated 12 / 1 7 / 2 0 2 4 1 1 : 3 6 : 5 5 A M A1.1 ELEVATIONS/ BLDG SECT./ DETAILS TTT OVG 12/04/2024 2024.01 1/8" = 1'-0"1 EAST ELEVATION 1/8" = 1'-0"2 SOUTH ELEVATION 1/8" = 1'-0"3 WEST ELEVATION 1/8" = 1'-0"4 NORTH ELEVATION 1/8" = 1'-0"5 LONGITUDINAL SECTION 1/8" = 1'-0"6 TRANSVERSE SECTION 1/2" = 1'-0"10 TOILET 2 - N 1/2" = 1'-0"11 TOILET 2 - E PROVIDE 2x BLOCKING, TYP 1/2" = 1'-0"9.TOILET 1- N 1/2" = 1'-0"8.TOILET 1 - W PROVIDE 2x BLOCKING, TYP 3/4" = 1'-0"13 MAIN/LARGE ROOF SCROLL (EAVE EDGE)3/4" = 1'-0"12 SIDE/SMALL ROOF SCROLL (EAVE EDGE) 1/8" = 1'-0"7 SECTION AT ALCOVE