HomeMy WebLinkAboutP_Construction_Documents_20250528_V1WH
WH
DN
DN
DN
WH
MECH.
RM
(E) OFFICE (E) UTILITY
ROOM
(E) SOCIAL HALL(E) BATH
(E) SOCIAL HALL
(E) STORAGE
DEMO EXIST
STAIRS
DEMO EXIST
SHOWER
7
A1.1
(E) OFFICE (E) UTILITY
ROOM
(E) SOCIAL HALL
(E) BATH
(E) SOCIAL HALL
(E) STORAGE
45' - 10"
23' - 4"
27
'
-
1
1
"
11
'
-
2
"
RA
M
P
D
N
MECH
RM
6
A1.1
1' - 3"
3'
-
0
"
A1.0
6
7
A1.1
(E) WORSHIP HALL
(E) OFFICE
(E)
TOILET(E) WORSHIP
AREA
(E)
MECH
(E) DECK
(E) PORCH
DN
DN
7
A1.1
(EXPANDED) WORSHIP HALL
RAMP DN
RA
M
P
DN
45' - 10"
23' - 4"
27
'
-
1
1
"
.
11
'
-
2
"
60
6
8
TOILET
30 68
12' - 6 3/4"7' - 10 1/2"
6'
-
7
3
/
4
"
6
A1.1
(E) DECK
(E
)
P
O
R
C
H
DN
DN
DS DS
DS DS
DS DS
2 A1.0
5
60 60 (30)60 60 (30)60 60 (30)
60 60 (30)60 60 (30)60 60 (30)
60 60 (30)
60
6
0
(
3
0
)
60
6
0
(
3
0
)
60 60 (30)
(N) FTG BELOW
19' - 3"7' - 9"7' - 5"6' - 4"
5' - 3"7' - 9"7' - 5"6' - 4"
7' - 5 1/2"7' - 5 1/2"
6'
-
7
1
/
2
"
7'
-
8
"
7'
-
0
"
7'
-
3
"
5'
-
4
"
NEW EXTERIOR
ADDITION
FILL-IN FLOOR TO
MATCH EXISTING
FILL-IN FLOOR TO
MATCH EXISTING
7
A1.1
DS DS
DS DS
DS DS
ROOF VENT CALCULATION:
1074 SF / 150 = 7.16
7.16 X 144 = 1032
1032 / 2 = 516 SQ. IN.
VENTS: 3" X 12" (36 SQ. IN.)
516 / 36 = 14 OR VENTS
ROOF DRAINAGE: AREA 1074 SF
DRAINAGE REQ'D: 1047 SF X .0028 = 3.0 SQ IN
DRAINAGE PROVIDED 6 SQ IN [1 (2x3}] DS
ROOF DRAINAGE: AREA 1074 SF
DRAINAGE REQ'D: 1047 SF X .0028 = 3.0 SQ IN
DRAINAGE PROVIDED 6 SQ IN [1 (2x3}] DS
ROOF DRAINAGE EA SIDE: AREA 170 SF
DRAINAGE REQ'D: 170 SF X .0028 = 0.5 SQ IN
DRAINAGE PROVIDED 6 SQ IN [1 (2x3}] DS
3" X 12" ROOF VENT, TYP OF 14
7
A1.1
TOILET
30 68
7' - 10 1/2"
6'
-
7
3
/
4
"
2
A1.1
10TOILET 2 -N
A1.1 11
TO
I
L
E
T
2
-
E
30"
48"
5'-4" DIA.
A1.1
(E) BATH
8.
TO
I
L
E
T
1
-
W
9.TOILET 1-N
5' - 10 1/2"
11
'
-
9
1
/
2
"
60"
56"
30
6
8
5'-4" DIA.
2
48"
30"
Scale
Date
Drawn By
Checked By
Project Number
NO.DATEDESCRIPTION
BO
D
E
T
E
M
P
L
E
RE
N
O
V
A
T
I
O
N
/
A
D
D
I
T
I
O
N
11
4
1
0
S
E
P
E
T
R
O
V
I
T
S
K
Y
R
D
RE
N
T
O
N
,
W
A
9
8
0
5
5
GESTOSO
DESIGN &
DRAFTING
SERVICES
22420 127TH
AVE SE KENT
WA 98031
(253) 709-7543
E: OSCAR.
GESTOSO
@GMAIL.COM
As indicated
12
/
1
7
/
2
0
2
4
1
1
:
3
6
:
5
3
A
M
A1.0
FLR PLANS/
ENERGY
NOTES/
PLAN KEY
TTT
OVG
12/04/2024
2024.01
1/8" = 1'-0"1 MAIN LEVEL - EXIST/DEMO
1/8" = 1'-0"2 MAIN LEVEL - PROPOSED
1/8" = 1'-0"3 UPPER LEVEL - EXIST/DEMO
1/8" = 1'-0"4 UPPER LEVEL - PROPOSED
1/8" = 1'-0"7 TOP OF ROOF
MAIN FLOOR PLAN NOTES
1/2" = 1'-0"5 ENLARGED TOILET PLAN 2
1/2" = 1'-0"6 ENLARGED TOILET PLAN 1
MAIN LEVEL -
EXIST/DEMO
0' -0"
UPPER LEVEL -
EXIST/DEMO
9' -2"
TOP OF ROOF
31' -7"
T.O. PLATE
19' -10 1/2"
FACTORY DIRECT STONE
ROOF TILES ON ROOF
CONSTRUCTION (SEE TYP
ROOF CONSTRUCTION
NOTES THIS SHT)
NEW ROOFS ADDITION7
A1.1
MAIN LEVEL -
EXIST/DEMO
0' -0"
UPPER LEVEL -
EXIST/DEMO
9' -2"
TOP OF ROOF
31' -7"
6
A1.1
T.O. PLATE
19' -10 1/2"
FACTORY DIRECT STONE
ROOF TILES ON ROOF
CONSTRUCTION (SEE TYP
ROOF CONSTRUCTION
NOTES THIS SHT)
NEW ROOF
ADDITIONS
NEW WALL ADDITION
R
1
9' -
6
1
1
/3
2
"R 19' - 6 11/32"
A1.1
12
MAIN LEVEL -
EXIST/DEMO
0' -0"
UPPER LEVEL -
EXIST/DEMO
9' -2"
TOP OF ROOF
31' -7"
T.O. PLATE
19' -10 1/2"
NEW ROOF ADDITIONS
NEW WALL ADDITION
A1.1
13
7
A1.1
MAIN LEVEL -
EXIST/DEMO
0' -0"
UPPER LEVEL -
EXIST/DEMO
9' -2"
TOP OF ROOF
31' -7"
6
A1.1
T.O. PLATE
19' -10 1/2"
FACTORY DIRECT STONE
ROOF TILES ON ROOF
CONSTRUCTION (SEE TYP
ROOF CONSTRUCTION
NOTES THIS SHT)
NEW ROOFS ADDITION
MAIN LEVEL -
EXIST/DEMO
0' -0"
UPPER LEVEL -
EXIST/DEMO
9' -2"
TOP OF ROOF
31' -7"
6
A1.1
(EXPANDED) WORSHIP HALL
(E) SOCIAL HALL
ATTIC
T.O. PLATE
19' -10 1/2"
SCISSOR TRUSS R-49 BATT INSULATION
R-21 BATT INSUL.R-21 BATT INSUL.
MAIN LEVEL -
EXIST/DEMO
0' -0"
UPPER LEVEL -
EXIST/DEMO
9' -2"
TOP OF ROOF
31' -7"
(EXPANDED)
WORSHIP HALL
(E) SOCIAL HALL (E) OFFICE
T.O. PLATE
19' -10 1/2"3" / 1'-0"
R-60 BATT INSULATION 5/8" GWB CLG ON SCISSOR TRUSSES @ 24" O.C. BY TRUSS MFG.
FACTORY DIRECT STONE ROOF
TILES ON ROOF CONSTRUCTION (SEE TYP
ROOF CONSTRUCTION NOTES THIS SHT)
3" X 12" VENTILATION SLOT
(SEE ROOF PLAN)
R 47' - 5 7/8"
R
4
7' - 5 7
/
8
"
R 47' -6"
R-21 BATT INSUL.
IN ADDED WALL
CONTINUOUS ROOF EDGE ROLL
7
A1.1
3'
-
0
"
1'
-
5
"
3'
-
4
"
2'
-
1
0
"
3' - 0"6".
1'
-
5
"
3'
-
0
"
1'
-
6
"
3'
-
3
"
1' - 0"3' - 6"
3' - 3"
1'
-
5
"
3'
-
0
"
1'
-
6
"
3'
-
3
"
3' - 6"1' - 0"
3' - 3"
2'
-
1
0
"
3'
-
4
"
1'
-
5
"
3'
-
0
"
R 1' - 3"
R 0 ' - 9 1 7 /3 2 "
R
1
'
-
6
1
/
2
"
R 0' - 9 3 /4 "R 0' - 5 27/32"
R 1'
- 8"
R
1
9' -
6
1
1
/
3
2
"
5/8" GWB CLG ON SCISSOR TRUSSES
@ 24" O.C. BY TRUSS MFG.
FACTORY DIRECT STONE ROOF
TILES ON ROOF CONSTRUCTION (SEE TYP
ROOF CONSTRUCTION NOTES THIS SHT)
R-60 BATT INSULATION IN CURVED ROOF FRAMING
3" X 12" VENTILATION SLOT
(SEE ROOF PLAN)
CONTINUOUS ROOF EDGE ROLL
Scale
Date
Drawn By
Checked By
Project Number
NO.DATEDESCRIPTION
BO
D
E
T
E
M
P
L
E
RE
N
O
V
A
T
I
O
N
/
A
D
D
I
T
I
O
N
11
4
1
0
S
E
P
E
T
R
O
V
I
T
S
K
Y
R
D
RE
N
T
O
N
,
W
A
9
8
0
5
5
GESTOSO
DESIGN &
DRAFTING
SERVICES
22420 127TH
AVE SE KENT
WA 98031
(253) 709-7543
E: OSCAR.
GESTOSO
@GMAIL.COM
As indicated
12
/
1
7
/
2
0
2
4
1
1
:
3
6
:
5
5
A
M
A1.1
ELEVATIONS/
BLDG
SECT./
DETAILS
TTT
OVG
12/04/2024
2024.01
1/8" = 1'-0"1 EAST ELEVATION
1/8" = 1'-0"2 SOUTH ELEVATION
1/8" = 1'-0"3 WEST ELEVATION
1/8" = 1'-0"4 NORTH ELEVATION
1/8" = 1'-0"5 LONGITUDINAL SECTION
1/8" = 1'-0"6 TRANSVERSE SECTION
1/2" = 1'-0"10 TOILET 2 - N
1/2" = 1'-0"11 TOILET 2 - E
PROVIDE 2x BLOCKING, TYP
1/2" = 1'-0"9.TOILET 1- N
1/2" = 1'-0"8.TOILET 1 - W
PROVIDE 2x BLOCKING, TYP
3/4" = 1'-0"13
MAIN/LARGE ROOF SCROLL (EAVE
EDGE)3/4" = 1'-0"12
SIDE/SMALL ROOF SCROLL (EAVE
EDGE)
1/8" = 1'-0"7 SECTION AT ALCOVE