Loading...
HomeMy WebLinkAboutP_Living Space Construction_Document_240514_v3DN WH DOOR/WINDOW LEGEND 30 68 3'-0" W x 6'-8" H DOOR 20 50 (40) 2'-0" W x 5'-0" H WDW (4'-0" HDR) SH SINGLE HUNG WINDOW XO CASEMENT WINDOW EE EMERGENCY EGRESS (MIN. 5.7 SF) SG SAFETY GLAZING 46 26 XO STORAGE BEDROOM 1 DINING RM BEDROOM 2 BEDROOM 3 BEDROOM 4 BEDROOM 5 KITCHEN BATH 1 49' - 11" 11' - 2" 21 ' - 6 1 / 2 " 5' - 1 " 13 ' - 0 " 3' - 5 1 / 2 " 21 ' - 6 1 / 2 " 12 ' - 0 1 / 2 " . 9' - 2 " 46 26 XO EE210 34 XO 210 36 SH EE 210 36 SH 46 26 XO EE 46 2 6 X O E E 33 2 6 X O E E 26 68 26 68 26 68 26 68 30 6 8 30 6 8 30 68 UPPER DECK LOWER DECK A2.1 4 SOUTH ELEVATION A2.1 6 WE S T EL E V A T I O N A2.1 5 NORTH ELEVATION A2.17 EA S T EL E V A T I O N WALL LEGEND EXISTING WALL/CASEWORK INTERIOR WALL: 1/2" GWB EA. SIDE OF 2x4 STUDS @ 16" O.C. INTERIOR FURRING WALL: 1/2" GWB EA SIDE O/ 2x2 STUDS @ 16" O.C. EXTERIOR WALL: EXIST. FIB-CEM SIDING O/ BLDG PAPER O/ 2x4 STUDS @ 16" O.C. W/ R-21 BATT INSUL. W/ POLY VAPOR BARRIER SEALED & TAPED. SD SD CM MECHANICAL/ELECTRICAL SYMBOLS EXHAUST FAN 50 CFM (BATH) / UTILITY 80 CFM / 100 CFM (KITCHEN) SMOKE DETECTOR SMOKE DETECTOR W/ CARBON MONOXIDE SD SD SD SD SD CMBATH 3 26 6 8 60 68 60 68 56 68 60 6 8 7' - 1 1/2"18' - 7 1/4" 26 6 8 26 68SD 56 6 8 2 A2.1 26 68 6' - 2 1/2" 26 6 8 6' - 0" 5' - 3 " 7' - 4 1 / 2 " 1 A2.1 10 ' - 9 1 / 2 " 10 ' - 0 " 5' - 3 " 5' - 0 " 10 ' - 1 " CRAWL SPACE ACCESS ATTIC ACCESS PANEL GOVERNING CODES 2021 IBC (INTERNATIONAL BUILDING CODE) 2021 INTERNATIONAL RESIDENTIAL CODE 2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)/WSEC 2021 INTERNATIONAL MECHANICAL CODE (IMC) 2021 INTERNATIONAL FIRE CODE (IFC) 2021 UNIFORM PLUMBING CODE (UPC) 2020 NATIONAL ELECTRICAL CODE (NEC) CRAWL SPACE ACCESS ATTIC ACCESS PANEL LIVING RM 3' - 4"4 1/2".9' - 9 1/2". 30 68 3' - 4"4 1/2".9' - 9 1/2".12' - 11"11' - 10 3/4" DS DS DS DS DS DS DS DS DS DS 4" / 1 ' - 0 " 5" / 1 ' - 0 " 4" / 1 ' - 0 " 5" / 1 ' - 0 " 1/4" / 1'-0" ROOF DRAINAGE: AREA 202 SF DRAINAGE REQ'D: 718 SF X .0028 = 0.57 SQ IN DRAINAGE PROVIDED 12 SQ IN [2 (2x3)] DS ROOF VENT CALCULATION: 404 SF / 300 = 1.35 1.35 X 144 = 194.4 194.4 / 2 = 97.2 SQ. IN. VENTS: 6" X 12" (72 SQ. IN.) 97.2 / 72 = 1.35 OR 2 VENTS ROOF DRAINAGE: AREA 190 SF DRAINAGE REQ'D: 718 SF X .0028 = 0.53 SQ IN DRAINAGE PROVIDED 12 SQ IN [2 (2x3)] DS ROOF DRAINAGE: AREA 202 SF DRAINAGE REQ'D: 718 SF X .0028 = 0.57 SQ IN DRAINAGE PROVIDED 12 SQ IN [2 (2x3)] DS ROOF DRAINAGE: AREA 190 SF DRAINAGE REQ'D: 718 SF X .0028 = 0.53 SQ IN DRAINAGE PROVIDED 12 SQ IN [2 (2x3)] DS ROOF VENT CALCULATION: 380 SF / 300 = 1.27 1.27 X 144 = 183.0 183.0 / 2 = 91.5 SQ. IN. VENTS: 6" X 12" (72 SQ. IN.) 91.5 / 72 = 1.27 OR 2 VENTS ROOF DRAINAGE: AREA 183 SF DRAINAGE REQ'D: 183 SF X .0028 = 0.23 SQ IN DRAINAGE PROVIDED 12 SQ IN [2 (2x3)] DS 1/4" = 1'-0"1 MAIN FLOOR PLAN (1077 SF) Scale Date Drawn By Checked By Project Number NO.DATEDESCRIPTION BO D E T E M P L E R E S I D E N C E 11 4 1 0 S E 1 1 6 T H S T RE N T O N , W A 9 8 0 5 5 GESTOSO DESIGN & DRAFTING SERVICES 22420 127TH AVE SE KENT WA 98031 (253) 709-7543 E: OSCAR. GESTOSO @GMAIL.COM 1/4" = 1'-0" 8/ 2 7 / 2 0 2 4 2 : 1 7 : 1 0 P M A1.0 MAIN/ ROOF/ FOUNDAT'N PLANS KG OVG 05/14/2024 2024.01 3 24" X 36" ATTIC ACCESS PANEL NTS 4 24" X 36" CRAWL SPACE ACCESS HATCH NTS 5 FOUNDATION/CRAWL SPACE VENT NTS 1/4" = 1'-0"2 TOP OF ROOF PLAN 6 ISOMETRIC VIEW 1 1 1 1 1 OWNER REVISION 08/23/24 PR22-000208 B24002581 Post Issuance Revision V2 REVISION Received: 08/29/2024 / MKamphaus BUILDING DIVISION REVIEWED Rick Lee 09/03/2024 BUILDING DIVISION THIS SET OF REVIEWED PLANS MUST BE MADE AVAILABLE ON THE JOB AT ALL TIMES DURING CONSTRUCTION. Note: This review is for the non-structural review only APPROVED BUILDING DIVISION THIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALL TIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BE OCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTON BUILDING DIVISION AND RECEIPT OF CERTIFICATE OF OCCUPANCY. APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TO VIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES, OR OTHER REGULATIONS ENFORCED BY THIS CITY. DATE: 09/10/2024 Scale Date Drawn By Checked By Project Number NO.DATEDESCRIPTION BO D E T E M P L E R E S I D E N C E 11 4 1 0 S E 1 1 6 T H S T RE N T O N , W A 9 8 0 5 5 GESTOSO DESIGN & DRAFTING SERVICES 22420 127TH AVE SE KENT WA 98031 (253) 709-7543 E: OSCAR. GESTOSO @GMAIL.COM 8/ 2 7 / 2 0 2 4 2 : 1 7 : 1 0 P M A1.1 FOUNDATION PLAN Checker Author 05/14/2024 2024.01 PR22-000208 B24002581 Post Issuance Revision V2 REVISION Received: 08/29/2024 / MKamphaus BUILDING DIVISION APPROVED BUILDING DIVISION THIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALL TIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BE OCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTON BUILDING DIVISION AND RECEIPT OF CERTIFICATE OF OCCUPANCY. APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TO VIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES, OR OTHER REGULATIONS ENFORCED BY THIS CITY. DATE: 09/10/2024 Scale Date Drawn By Checked By Project Number NO.DATEDESCRIPTION BO D E T E M P L E R E S I D E N C E 11 4 1 0 S E 1 1 6 T H S T RE N T O N , W A 9 8 0 5 5 GESTOSO DESIGN & DRAFTING SERVICES 22420 127TH AVE SE KENT WA 98031 (253) 709-7543 E: OSCAR. GESTOSO @GMAIL.COM 1/2" = 1'-0" 8/ 2 7 / 2 0 2 4 2 : 1 7 : 1 0 P M A1.2 CODE NOTES/ SPECS KG OG 05/14/2024 2024.01 IBC AND IEBC CODE COMPLIANCE NOTES A. LOCAL JURISDICTION: CITY OF RENTON B. GOVERNING CODES: 1. 2021 INTERNATIONAL BUILDING CODE (IBC) WITH STATEWIDE AMENDMENTS 2. ICC/ANSI A117.1-09, ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES, WITH STATEWIDE AMENDMENTS 3. 2021 INTERNATIONAL RESIDENTIAL CODE (IRC0 WITH STATEWIDE AMENDMENTS 4. 2021 INTERNATIONAL MECHANICAL CODE (IMC) WITH STATEWIDE AMENDMENTS 5. 2021 INTERNATIONAL FIRE CODE (IFC) WITH STATEWIDE AMENDMENTS 6. 2021 UNIFORM PLUMBING CODE (UPC) WITH STATEWIDE AMENDMENTS 7. 2021 WASHINGTON STATE ENERGY CODE-RESIDENTIAL, CHAPTER 51-11R WAC. 8. 2021 INTERNATIONAL EXISTING BUILDING CODE WITH STATEWIDE AMENDMENTS 9. NATIONAL ELECTRICAL CODE (NFPA 70) C. CODE COMPLIANCE OF WORK THE SCOPE OF WORK IN THESE DRAWINGS IS TO DEMO MOST OF EXISTING STRUCTURE, CONSTRUCT NEW BASEMENT, MAIN FLOOR AND ADD UPPER FLOOR. D. BUILDING CODE ANALYSIS 1. OCCUPANCY GROUP: R-3 2. CONSTRUCTION TYPE: V-B 3. FIRE RESISTIVE RATING REQUIREMENTS: a. THE MAIN STRUCTURE HAS NO FIRE RATING REQS. (PER TABLE 601). b. FIRE RESISTANCE OF EXTERIOR WALLS BASED ON FIRE SEPARATION DIST. PER IBC TABLE 602 & SECTION 705: NONE REQUIRED. 1. ALLOWABLE HEIGHT AND STORIES (PER SECTION 504): a. ALLOWED: 35 FEET & 2 STORIES FOR NON-SPRINKLERED R-2 OCCUPANCY. 2. ALLOWABLE FLOOR AREA (PER IBC CH 5): a. BASIC ALLOWABLE AREA: 7000 SF NON-SPRINKLERED EXISTING R-2 BLDG. b. AREA INCREASES: MULTI STORY (3.0) AND FRONTAGE INCREASE PER IBC 506. APPLIED TO BOTH • MULTI STORY: 3 FLOORS • FRONTAGE INCR. = 75% E. 1. STAIRS: COMPLY WITH IBC 1011 a. STAIR WIDTH: 36" MINIMUM 2. EXIT ACCESS WIDTH: COMPLIES. a. AISLES: 36" MIN. REQUIRED & PROVIDED F. FIRE SUPPRESSION AND ALARM SYSTEMS 1. SPRINKLERS AND FIRE ALARM: NOT REQUIRED. THE OCCUPANCY CLASSIFICATION (R-RESIDENTIAL) IS NOT CHANGING TO ANOTHER CATEGORY WITH AN INCREASED REQUIREMENT IN IBC CH. 9 WA STATE ENERGY CODE COMPLIANCE NOTES ENERGY STAR RATED APPLIANCES REFRIGERATOR REFRIGERATOR WASHER DRYER RHEEM WATER HEATER SPECIFICATIONS EVERBILT 2 GAL EXPANSION TANK SPECIFICATIONS 1/2" = 1'-0"1 WATER HEATER SUPPORT PR22-000208 B24002581 Post Issuance Revision V2 REVISION Received: 08/29/2024 / MKamphaus BUILDING DIVISION APPROVED BUILDING DIVISION THIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALL TIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BE OCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTON BUILDING DIVISION AND RECEIPT OF CERTIFICATE OF OCCUPANCY. APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TO VIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES, OR OTHER REGULATIONS ENFORCED BY THIS CITY. DATE: 09/10/2024 CRAWL SPACE ATTIC ATTIC STORAGE BATH 3 DINING RM BEDROOM 4 HALLWAY BEDROOM 5 KITCHEN CRAWL SPACE 8' - 6 " R-49 R-30 R-49 R-30 R-21 R-21 CRAWL SPACE A2.1 3 1/4" / 1'-0" 1/4" / 1'-0" 4 " / 1 '-0 "4" / 1'-0" 1 A2.1 4 " / 1 '-0 "4" / 1'-0" 5 " / 1 '-0 "5" / 1'-0" 1 A2.1 Scale Date Drawn By Checked By Project Number NO.DATEDESCRIPTION BO D E T E M P L E R E S I D E N C E 11 4 1 0 S E 1 1 6 T H S T RE N T O N , W A 9 8 0 5 5 GESTOSO DESIGN & DRAFTING SERVICES 22420 127TH AVE SE KENT WA 98031 (253) 709-7543 E: OSCAR. GESTOSO @GMAIL.COM As indicated 8/ 2 7 / 2 0 2 4 2 : 1 7 : 1 1 P M A2.1 BUILDING SECTIONS/ EXTERIOR ELEVATIONS KN OG 05/14/2024 2024.01 1/4" = 1'-0"1 LONGITUDINAL SECTION 1/4" = 1'-0"2 TRANSVERSE SECTION 1/2" = 1'-0"3 WALL SECTION 1/4" = 1'-0"4 SOUTH ELEVATION 1/4" = 1'-0"5 NORTH ELEVATION 1/4" = 1'-0"6 WEST ELEVATION 1/4" = 1'-0"7 EAST ELEVATION PR22-000208 B24002581 Post Issuance Revision V2 REVISION Received: 08/29/2024 / MKamphaus BUILDING DIVISION APPROVED BUILDING DIVISION THIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALL TIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BE OCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTON BUILDING DIVISION AND RECEIPT OF CERTIFICATE OF OCCUPANCY. APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TO VIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES, OR OTHER REGULATIONS ENFORCED BY THIS CITY. DATE: 09/10/2024