Loading...
HomeMy WebLinkAboutA4 Falcon_Ridge_Lift_Station_90pct_Crit Area SubmitSE 8TH PL TP1 CONSTRUCTION LIMIT N: 175512.43 E: 1306016.27 CONSTRUCTION LIMIT N: 175442.57 E: 1305988.19 CONSTRUCTION LIMIT N:175429.30 E: 1306010.31 CONSTRUCTION LIMIT N: 175434.36 E: 1306029.03 CONSTRUCTION LIMIT N: 175449.56 E: 1306039.08 CONSTRUCTION LIMIT N: 175459.53 E: 1306030.04 CONSTRUCTION LIMIT N: 175483.43 E: 1306034.92 CONSTRUCTION LIMIT N: 175506.37 E: 1306031.63 CONSTRUCTION LIMIT N: 175507.20 E: 1306008.25 CONSTRUCTION LIMIT N: 175504.57 E: 1305988.11 REBAR CAP BENCHMARK BOLLARD BOLLARD TO BE REMOVED WATER METER FIRE HYDRANT (2 PORT) WATER GATE VALVE STORM DRAIN MANHOLE CULVERT DAYLIGHT SANITARY SEWER MANHOLE IRRIGATION VALVE POWER VAULT TELEVISION PEDESTAL POWER PAD MOUNT TRANSFORMER TEST PIT DECIDUOUS TREE CONIFEROUS TREE DECIDUOUS TREE TO BE REMOVED CONIFEROUS TREE TO BE REMOVED FENCE (AS NOTED) FENCE TO BE REMOVED UNDERGROUND TELEPHONE NATURAL GAS UNDERGROUND POWER SANITARY SEWER SEWER FORCEMAIN STORM DRAIN MAIN WATER MAIN RIGHT OF WAY LINE CENTER RIGHT OF WAY LINE PROPERTY LINE PROPERTY SECTION BOUNDARY ASPHALT ROAD CONCRETE DRIVEWAY AHFJDHApr 9, 2018Apr 9, 2018REN117-038FCLS-D-CIV01.DWGSHOWN C01 3 32 DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE:PRELIMINARYwww.rh2.comRH2 ENGINEERING, INC.Bothell, Wa22722 29th Drive SE, Suite 2101.800.720.8052EXISTING SITE PLANCITY OF RENTONFALCON RIDGE LIFT STATIONCITY OF RENTONFALCON RIDGE LIFT STATIONEXISTING SITE PLAN EXISTING LEGEND EXISTING LIFT STATION1 EXISTING POWER UTILITIES2 2 1 SILT FENCE TO BE INSTALLED PRIOR TO CONSTRUCTION 207 TAKE ALL NECESSARY MEASURES TO PROTECT TREES NOT MARKED FOR REMOVAL BOLLARD, TO BE REMOVED ELECTRICAL PANEL, TO BE REMOVED TELEMETRY PANEL, TO BE REMOVED VACUUM-PRIMED PUMPS AND PIPING, TO BE REMOVED EXISTING SITE3 EXISTING GAS MONITORING STATION. DO NOT DISTURB EXISTING PARK BOUNDARY STAKE AND PROPERTY CORNER TO BE REPLACED WITH SURVEY PINS 3 1 CITY AND FIRE DEPARTMENT MUST HAVE ACCESS TO FIRE HYDRANT AT ALL TIMES. UNDER NO CIRCUMSTANCES SHALL HYDRANT ACCESS BE BLOCKED OR LIMITED. DO NOT BLOCK SWING GATE. PRIVATE ACCESS TO SOUTHERN PROPERTY THROUGH GATE SHALL BE MAINTAINED AT ALL TIMES. DO NOT BLOCK GATE. WHILE LIFT STATION IS IN OPERATION, CITY MUST HAVE FULL ACCESS TO EXISTING LIFT STATION AT ALL TIMES. DO NOT BLOCK ACCESS TO HOUSE AND DRIVEWAY FROM SE 8TH PL. 2 3 1 2 3 NTC: MAY THE CONTRACTOR USE SOME/ALL OF THE PARKING SPACES WEST OF THE EXISTING WET WELL? CONSTRUCTION LIMITS. NO WORK MAY TAKE PLACE BEYOND THIS BOUNDARY ON THE PARKS PARCEL. 4 4 EXISTING FENCE TO BE REMOVED SE 8TH PL 00 B0 64 B0 00 A066 A0-2.68% -1 . 3 7 %-2.74%371 372 373 374 375376 377 375375-10 C-000 C050 C0EAST-WEST (A) PROFILE 360' 370' 380' 390' 360' 370' 380' 390' 0+000+66 2 1 NORTH-SOUTH (B) PROFILE 360' 370' 380' 390' 360' 370' 380' 390' 0+00 0+64 2 1 PROPOSED LIFT STATION LOCATION AHFJDHApr 9, 2018Apr 9, 2018REN117-038FCLS-D-CIV02.DWGSHOWN C02 4 32 DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE:PRELIMINARYwww.rh2.comRH2 ENGINEERING, INC.Bothell, Wa22722 29th Drive SE, Suite 2101.800.720.8052PROPOSED OVERALL SITE PLANCITY OF RENTONFALCON RIDGE LIFT STATIONCITY OF RENTONFALCON RIDGE LIFT STATIONELECTRICAL BUILDING, SEE DWG NO. S01 FOR ADDITIONAL INFORMATION EG WETWELL, SEE DWG NOS. S03 AND M01 FOR ADDITIONAL INFORMATION VALVE VAULT, SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION PROPOSED LEGEND PROPOSED OVERALL SITE PLAN 1 1 20' GATE JUNCTION BOX ENCLOSURE, SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION ELECTRICAL BUILDING EG SLAB WETWELL VALVE VAULT GRAVEL PATH, 3' WIDE UNLESS OTHERWISE NOTED 6' WIDTH x 6' LENGTH x 1.5' DEPTH ROCK PROTECTION OUTFALL SHALL BE QUARRY SPALLS IN ACCORDANCE WITH SECTION 9-13.6 OF THE STANDARD SPECIFICATIONS. PROVIDE 1' COVER OVER TOP OF PIPE. 8" PVC STORM PIPE, APPROX. LENGTH 23' 25-SA OIL-WATER SEPARATOR VAULT OR APPROVED EQUAL. IE IN = 374.05' IE OUT = 373.95' THICKENED ASPHALT CURB IE OUT = 370.0' TYPE 1 CATCH BASIN. RIM EL = 374.85' IE OUT = 372.33' 4" DI TEE WITH THRUST BLOCK. INSTALL (2) 4" GATE VALVES AND (3) PVC FLANGE ADAPTERS ON TEE 8" PVC PIPE, APPROX. LENGTH 25'-0" PROPOSED CHAIN LINK FENCE 4" PVC RJ PIPE, APPROX. LENGTH 24'. SEE ABANDONMENT NOTES ON DWG NO. G01 FOR ADDITIONAL PHASING AND CONSTRUCTION INFORMATION. PROPOSED PAVEMENT RESTORATION SHALL MATCH GRADE ON NORTH AND WEST SIDES. SEE DWG NO. C05 FOR DETAILS PROPOSED PAVEMENT, SEE DWG NOS. C03 AND C05 FOR ADDITIONAL INFORMATION PROPOSED FENCE EXISTING GRADE PROPOSED GRADE EXISTING GRADE PROPOSED GRADE EXCAVATED MATERIAL MAY BE REUSED FOR SITE FILL PROVIDED THAT 6" AND LARGER OBJECTS AND ORGANIC DEBRIS ARE REMOVED PRIOR TO PLACEMENT. PROTECT EXCAVATED MATERIAL FROM EXCESS MOISTURE. DURING PLACEMENT, BACKFILL SHOULD BE PLACED AT OPTIMAL MOISTURE IN 6" LOOSE LIFTS AND COMPACTED TO A FIRM AND UNYIELDING CONDITION AT LEAST 95% OF MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST (ASTM D 1557). PROPOSED IMPERVIOUS AREA: 1,990 SF INCLUDING PAVEMENT AT EXISTING LIFT STATION DO NOT DISTURB EXISTING APPURTENANCE SITE LIGHTING, TYP. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. CORE DRILL PENETRATION FOR PROPOSED PIPE. PIPE IE SHALL MATCH EXISTING FLOOR ELEVATION, APPROXIMATELY 360.74' CONTRACTOR TO VERIFY. PROPOSED FLAT TOP FOR EXISTING MANHOLE 8" PVC STORM PIPE, APPROX. LENGTH 2.5' VENT PIPING AND CONCRETE PAD TO BE INSTALLED OUTSIDE FENCE. PROVIDE FINE GRADING TO ACCOMMODATE PAD.204 208 CONNECTION TO EXISTING SYSTEM 1 THE EXISTING STATION MUST REMAIN ONLINE AND OPERATIONAL UNTIL WRITTEN CONSENT HAS BEEN ISSUED BY THE OWNER TO THE CONTRACTOR TO ABANDON THE EXISTING FACILITY. IN ORDER TO CONNECT THE DISCHARGE PIPE FROM THE EXISTING WET WELL AND THE PROPOSED FORCEMAIN TO THE EXISTING FORCE MAIN, THE CONTRACTOR WILL PLUG THE DISCHARGE PIPE OF MANHOLE #10040 AND UTILIZE VACTOR TRUCKING AS NECESSARY TO REMOVE INCOMING FLOWS WHILE PROPOSED CONNECTIONS ARE INSTALLED. AT NO TIME SHALL THE LEVEL IN MANHOLE #10040 EXCEED 366.0'. PROPOSED DISCHARGE PIPE FROM EXISTING WET WELL SHALL BE CORED. SEE CITY OF RENTON STANDARD MANHOLE DETAIL FOR CONNECTION DETAIL. INSTALL PLUG AT UPSTREAM END TO PREVENT FLOW UNTIL PROPOSED STATION IS APPROVED IN WRITING FOR OPERATION WITH WASTE WATER. TEE CLUSTER WILL BE INSTALLED WITH EAST GATE VALVE NORMALLY CLOSED WITH A TEMPORARY BLIND FLANGE UNTIL FINAL CONNECTION IS APPROVED. SEE CONNECTION DETAIL THIS SHEET. SEE ABANDONMENT NOTES ON DWG NO. G01 FOR ADDITIONAL INFORMATION. 2 FITTINGS PER PLAN CONNECTION DETAIL 1 2 PROTECT EXPOSED DISTURBED EARTH FROM EROSION VIA MULCH OR HYDROSEEDING. MAN ACCESS GATE 210 200 101 111 106 105 103 102 00 B0 64 B0 00 A066 A0-2.68% -1 . 3 7%-2.74%371 372 373 374 375376 377 375375203 204 205 206 207 210 109 108 107 110 112 113 114 117 116 115 202 302 303 304 305 306 307 308 309 208 209 -10 C-000 C050 C0310 104 311 EAST-WEST (C) PROFILE 350' 360' 370' 380' 390' 350' 360' 370' 380' 390' -0+10 0+00 0+50 POINT TABLE POINT NO. 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 202 ELEV. 375.18 375.41 375.30 375.51 375.30 375.30 375.00 375.30 375.10 374.95 375.10 375.00 375.10 375.15 375.15 375.10 375.10 375.26 NORTHING 175483.83 175464.32 175462.09 175452.35 175448.22 175450.34 175472.76 175471.86 175471.19 175492.08 175489.11 175490.58 175488.49 175490.33 175488.64 175486.80 175486.43 175453.98 EASTING 1305975.30 1305981.69 1305989.56 1305982.54 1306008.80 1306024.40 1306028.08 1306021.47 1306016.52 1306025.45 1306014.08 1306014.39 1306009.58 1306009.33 1305996.86 1305997.11 1305994.43 1306010.34 DESC. EOP EOP EOP EOP EOP EOP EOG EOP EOP EOG EOP EOP EOP EOP EOP EOP EOP WETWELL POINT TABLE POINT NO. 203 204 205 206 207 208 209 210 302 303 304 305 306 307 308 309 310 311 ELEV. 375.30 375.24 375.18 375.17 375.10 374.85 374.96 375.10 375.33 375.55 375.57 375.65 375.28 375.13 374.75 375.22 375.14 375.30 NORTHING 175452.49 175457.44 175461.79 175463.89 175476.97 175477.39 175482.43 175487.54 175464.62 175461.68 175447.70 175449.92 175471.93 175472.36 175499.93 175496.47 175484.61 175474.61 EASTING 1306017.13 1306016.46 1305999.39 1306014.84 1306015.74 1306005.12 1306008.10 1306014.30 1305986.93 1305989.26 1306008.67 1306024.97 1306021.97 1306025.11 1306013.12 1305987.72 1305987.53 1305987.23 DESC. PANEL PANEL VAULT VAULT BLDG CB OWS BLDG FENCE FENCE FENCE FENCE FENCE FENCE FENCE FENCE FENCE FENCE AHFEHApr 9, 2018Apr 9, 2018REN117-038FCLS-D-CIV02.DWGSHOWN C03 5 32 DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE:PRELIMINARYwww.rh2.comRH2 ENGINEERING, INC.Bothell, Wa22722 29th Drive SE, Suite 2101.800.720.8052PROPOSED SITE PLANCITY OF RENTONFALCON RIDGE LIFT STATIONCITY OF RENTONFALCON RIDGE LIFT STATIONPROPOSED SITE PLAN EG WETWELL, SEE DWG NOS. S03 AND M01 FOR ADDITIONAL INFORMATION VALVE VAULT, SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION ROOF OUTLINE 12' PAVEMENT RADIUS EXISTING WET WELL PROPOSED INFLUENT GRAVITY PIPE PROPOSED WET WELL PROPOSED MANHOLE TOP SHALL BE 108" DIAMETER FLAT TOP FOR EXISTING 6' DIAMETER STRUCTURE WITH MANHOLE FRAME AND COVER. CENTER OF COVER SHALL BE 33" FROM EDGE OF SLAB. EXISTING GRADE PROPOSED GRADE PROPOSED TOP SLAB EXISTING MANHOLE ASPHALT PAVEMENT201 6" CRUSHED ROCK, COMPACTED TO A FIRM AND UNYIELDING CONDITION EXISTING NATIVE MATERIAL, COMPACTED PRIOR TO GRAVEL PLACEMENT PROPOSED SLAB ON EXISTING MANHOLE 200 200 ELECTRICAL BUILDING, SEE DWG NO. S01 FOR ADDITIONAL INFORMATION SLOPE EXISTING PAVEMENT AS SHOWN