Loading...
HomeMy WebLinkAboutCONSOLIDATED_C25000233_Renton Market_CCP_20251002BU R N E T T A V E S WELLS AVE S BU R N E T T P L S MILL AVE S N RIVERSIDE DR MAIN AVE S S 2ND ST S 2ND ST N 1ST ST CEDAR AVE S WIL L I A M S A V E S BURNETT AVE S SHATTUCK AVE S MORRIS AVE S S 3RD ST MORRIS AVE S S 3RD ST S TOBIN ST WE L L S A V E S SH A T T U C K A V E S S 4TH ST MO R R I S A V E S SH A T T U C K A V E S BURNETT AVE S S 3RD PL MIL L A V E S HOUSER WAY SWILLIAMS AVE S S 4TH ST HOUSER WAY S LOGAN AVE S S 3RD ST S 2ND ST BURNETT AVE S S 2ND ST BURNETT AVE S S 3RD ST S 2ND ST N RIVERSIDE DR S TOBIN ST S 4TH ST SM I T H E R S A V E S WILLIAMS AVE S S 3RD ST PELLY AVE N MAIN AVE S S 4TH ST WILLIAMS AVE S HOUSER WAY S LO G A N A V E S MILL AVE S WHITWORTH AVE S MAIN AVE S WELLS AVE S S 4TH ST BRONSON WAY N S 3RD ST S 4TH ST MA I N A V E S WILLIAMS AVE S S 4TH ST S 3RD ST S 3RD ST WHITWORTH AVE S SMITHERS AVE S WELLS AVE S WH I T W O R T H A V E S S 2ND ST HOUSER W A Y S WILLIAMS AVE S S 2ND ST LOGAN AVE S S 2ND ST MAIN AVE S S 2ND ST HOUSER WAY S S TOBIN STS TOBIN ST MORRIS AVE S WELLS AVE S WELLS AVE S N 1ST ST SHATTUCK AVE S S 4TH PL HOUSER WAY S HOUSER WAY S SHATTUCK AVE S BRONSON WAY N MAIN AVE S S 3RD ST S 3RD ST BRONSON WAY N S 2ND STS 2ND ST S 2ND ST SMITHERS AVE S S 2ND ST S 2ND ST I-405 FWY PROJECT LOCATION Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 VICINITY MAP 1" = 500'±RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT COVER R-433401 2025-07-15 REGIONAL FIRE AUTHORITY cthomas 08/12/2025 APPROVED amorganroth 08/12/2025 CURRENT PLANNING Surface Water Enginering jfarah 08/12/2025 WASTEWATER UTILITY jstowell 08/13/2025 DEVELOPMENT ENGINEERING msippo 08/13/2025 WASTEWATER UTILITY jstowell 08/13/2025 WATER UTILITY ABDOUL GAFOUR 08/13/2025 BU R N E T T A V E S WELLS AVE S BU R N E T T P L S MILL AVE S N RIVERSIDE DR MAIN AVE S S 2ND ST S 2ND ST N 1ST ST CEDAR AVE S WIL L I A M S A V E S BURNETT AVE S SHATTUCK AVE S MORRIS AVE S S 3RD ST MORRIS AVE S S 3RD ST S TOBIN ST WE L L S A V E S SH A T T U C K A V E S S 4TH ST MO R R I S A V E S SH A T T U C K A V E S BURNETT AVE S S 3RD PL MIL L A V E S HOUSER WAY SWILLIAMS AVE S S 4TH ST HOUSER WAY S LOGAN AVE S S 3RD ST S 2ND ST BURNETT AVE S S 2ND ST BURNETT AVE S S 3RD ST S 2ND ST N RIVERSIDE DR S TOBIN ST S 4TH ST SM I T H E R S A V E S WILLIAMS AVE S S 3RD ST PELLY AVE N MAIN AVE S S 4TH ST WILLIAMS AVE S HOUSER WAY S LO G A N A V E S MILL AVE S WHITWORTH AVE S MAIN AVE S WELLS AVE S S 4TH ST BRONSON WAY N S 3RD ST S 4TH ST MA I N A V E S WILLIAMS AVE S S 4TH ST S 3RD ST S 3RD ST WHITWORTH AVE S SMITHERS AVE S WELLS AVE S WH I T W O R T H A V E S S 2ND ST HOUSER W A Y S WILLIAMS AVE S S 2ND ST LOGAN AVE S S 2ND ST MAIN AVE S S 2ND ST HOUSER WAY S S TOBIN STS TOBIN ST MORRIS AVE S WELLS AVE S WELLS AVE S N 1ST ST SHATTUCK AVE S S 4TH PL HOUSER WAY S HOUSER WAY S SHATTUCK AVE S BRONSON WAY N MAIN AVE S S 3RD ST S 3RD ST BRONSON WAY N S 2ND STS 2ND ST S 2ND ST SMITHERS AVE S S 2ND ST S 2ND ST I-405 FWY PROJECT LOCATION Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 VICINITY MAP 1" = 500'±RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT COVER R-433401 1 1 2025-09-15 WATER UTILITY JValdez 09/17/2025 AMorganroth 09/22/2025 CURRENT PLANNINGDEVELOPMENT ENGINEERING msippo 10/02/2025 NOTESCall 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES: (STD PLAN 268.00) 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE- CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT' S CONTRACTOR. 2. THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT. 3. THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO POST- PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. 4. THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK- OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE. 6. WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF- SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES. ON- SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUT AREAS. 7. ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/ OR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/ OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON- SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON- SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT. 8. ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY. 9. THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 10. APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR STORMWATER FACILITIES. 11. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 12. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1ST THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM. 13. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY. 14. ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS. 15. THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY. 16. BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216. 30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION. 17. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT- LADEN WATER INTO THE DOWNSTREAM SYSTEM. 18. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY. 19.AREAS DESIGNATED ON THE PLAN(S) CONTAINING EXISTING STORMWATER FACILITIES OR ON- SITE BMPS (AMENDED SOILS, BIORETENTION, PERMEABLE PAVEMENT, ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION. 20. PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON.AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW. 21. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT- LADEN WATER FROM LEAVING THE PROJECT SITE, ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON- SITE BMPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM, DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL. MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST. 22. ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS- OF- WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF ROAD RIGHTS- OF- WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. CITY OF RENTON WASTEWATER UTILITY STANDARD NOTES (STD PLAN 413) 1.ALL WORK AND MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY OF RENTON PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/ APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON STANDARD PLANS& SPECIFICATIONS.A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2.DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988. HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/ 1991 UNLESS OTHERWISE APPROVED BY THE CITY. BENCHMARKS AND MONUMENTS SHALL BE REFERENCED ON THE APPROVED PLANS. 3.A PRE- CONSTRUCTION CONFERENCE AND A 24- HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR' S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS, INCLUDING STREET USE PERMITS, PRIOR TO STARTING CONSTRUCTION. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY. IT SHALL BE THE CONTRACTOR' S RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 4.THE HOURS OF WORK IN THE STREET RIGHT- OF- WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT. AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT- OF-WAY. 5.CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REQUIREMENTS. 6.ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR' S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. THE CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF RCW 19. 122. A DIG TICKET SHALL BE OBTAINED A MINIMUM OF TWO BUSINESS DAYS PRIOR TO STARTING ANY EXCAVATION. THE CONTRACTOR SHALL HAVE A COPY OF THE DIG TICKET ON SITE AT ALL TIMES. 7.BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 12- INCHES, MAXIMUM DEPTH 18- INCHES, THOROUGHLY COMPACTING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER THE PIPE SHALL BE EQUIVALENT TO BANK RUN GRAVEL FOR TRENCH BACKFILL( 9- 03. 19). 8.SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE( PVC) RUBBER- GASKETED ASTM D 3034, SDR 35, C900/ C905 OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE CITY. 9.SANITARY SEWER PIPES SHALL NOT BE LOCATED UNDER ANY STRUCTURE( WALL, BUILDING FOUNDATION, ETC.) UNLESS APPROVED BY THE CITY. IF A SANITARY SEWER IS TO BE LOCATED UNDER ANY STRUCTURE( WALL, BUILDING FOUNDATION, ETC.), IT SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON IN ACCORDANCE WITH STANDARD DETAIL 412. 10.OPEN- CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAYS SHALL BE BACKFILLED WITH CRUSHED SURFACING AGGREGATE( WSDOT SPECIFICATION 9-03. 9( 3) AND MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY. 11.ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY AND THE LATEST EDITION OF THE WSDOT/ APWA STANDARDS AND SPECIFICATION AS APPROVED AND MODIFIED BY THE CITY IN THE RENTON STANDARD PLANS& SPECIFICATIONS. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL TO A UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. PIPE BEDDING SHALL BE IN ACCORDANCE WITH STANDARD PLAN 405. 12.ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE CITY FOR THE PREVENTION OF ON- SITE EROSION BOTH DURING CONSTRUCTION AND AFTER THE COMPLETION OF CONSTRUCTION IN ACCORDANCE WITH THE CURRENT SURFACE WATER DESIGN MANUAL. 13.THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH A RECORD DRAWING OF THE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. R-433402 2025-07-15 DEVELOPMENT ENGINEERING msippo 08/13/2025 NOTESCall 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 CITY OF RENTON CCTV INSPECTION STANDARD NOTES: 1.ALL NEWLY- INSTALLED AND NEWLY- REHABILITATED ( PUBLIC AND PRIVATE) SANITARY SEWER AND STORM DRAIN MAIN LINES SHALL BE INSPECTED BY MEANS OF REMOTE CCTV. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY OF RENTON INSPECTOR ASSIGNED TO THE PROJECT PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS, AND/ OR PAVEMENT. 2.THE CONTRACTOR SHALL PERFORM ALL CCTV INSPECTIONS IN ACCORDANCE WITH THE NATIONAL ASSOCIATION OF SEWER SERVICE COMPANIES ( NASSCO) PIPELINE ASSESSMENT CERTIFICATION PROGRAM ( PACP). 3.ALL CCTV OPERATORS SHALL HAVE CURRENT NASSCO PACP CERTIFICATION. 4.CCTV INSPECTIONS SHALL BE RECORDED IN A GRANITENET COMPATIBLE FORMAT DATABASE USING THE LATEST SOFTWARE VERSION AND SUBMITTED WITH ELECTRONIC LINKS BETWEEN THE DATA AND THE VIDEO ON AN EXTERNAL HDD, DVD, OR FLASH DRIVE. 5.ALL CCTV INSPECTION REPORTS SHALL BE WITHIN +/- TWO ( 2) FEET OF THE MEASURED LINEAR FOOTAGE BETWEEN MANHOLES ALONG THE EXISTING PIPELINE CENTERLINE FROM THE START OF PIPE TO END OF PIPE. 6.ALL OWNER AND PACP REQUIRED HEADER INFORMATION MUST BE FULLY AND ACCURATELY ENTERED ON ALL CCTV REPORTS. WORK NOT FOLLOWING THESE SPECIFICATIONS WILL BE REJECTED AND THE CONTRACTOR SHALL BE REQUIRED TO RE- CCTV THE WORK. 7.THE DOCUMENTATION OF THE WORK SHALL CONSIST OF PACP CCTV REPORTS, PACP DATABASE, LOGS, ELECTRONIC REPORTS, ETC. NOTING IMPORTANT FEATURES ENCOUNTERED DURING THE INSPECTION. THE SPEED OF TRAVEL SHALL BE SLOW ENOUGH TO INSPECT EACH PIPE JOINT, TEE CONNECTION, STRUCTURAL DETERIORATION, INFILTRATION AND INFLOW SOURCES, AND DEPOSITS, BUT SHOULD NOT, AT ANY TIME, BE FASTER THAN 30 FEET PER MINUTE, EXCEPT AS NOTED OTHERWISE IN THIS DOCUMENT. 8.THE CAMERA MUST BE CENTERED IN THE PIPE TO PROVIDE ACCURATE DISTANCE MEASUREMENTS TO PROVIDE LOCATIONS OF FEATURES IN THE SEWER AND THESE FOOTAGE MEASUREMENTS SHALL BE DISPLAYED AND DOCUMENTED ON THE VIDEO. ALL PACP OBSERVATIONS SHALL BE IDENTIFIED BY AUDIO AND ON A PACP LOG. ALL VIDEO MUST BE CONTINUOUSLY METERED FROM MANHOLE TO MANHOLE. ALL VIDEO RECORDING SHALL BE CONTINUOUS FROM STRUCTURE TO STRUCTURE WITH NO " PAUSING" OF THE VIDEO RECORDING DURING EACH PIPELINE INSPECTION. THE PIPE SHALL BE CLEANED PRIOR TO THE CCTV INSPECTION TO ENSURE ALL DEFECTS, FEATURE, AND OBSERVATIONS ARE SEEN AND LOGGED. 9.JUST PRIOR TO BEGINNING THE CCTV INSPECTION, WHILE THE CCTV CAMERA IS IN PLACE AND RECORDING, WATER ( CONTAINING DYE) SHALL BE INTRODUCED INTO THE UPSTREAM MANHOLE OF EACH PIPE SEGMENT UNTIL IT IS OBSERVED AND RECORDED FLOWING PAST THE CAMERA' S FIELD OF VISION IN ITS ENTIRETY. 10.THE CCTV CAMERA SHALL HAVE A WATER- LEVEL MEASURING DEVICE ( BALL, CYLINDER, ETC.) ATTACHED THAT HAS 1/4" MARKINGS TO SHOW THE DEPTH OF WATER IN THE PIPE DURING THE CCTV INSPECTION. 11.ALL MANHOLES SHALL BE CHANNELED AND COATED PRIOR TO CCTV INSPECTION. 12.PER CITY OF RENTON SPECIFICATION 7-08. 3(2)B, SEWER AND STORM DRAIN PIPELINE SHALL HAVE NO MORE THAN 1/2" OF PONDING TO BE CONSIDERED ACCEPTABLE. CITY OF RENTON SURFACE WATER STANDARD NOTES: (STD PLAN 267.00 AND 267.10) 1.BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE- CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT' S CONTRACTOR. 2.THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION. 3.ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL ( RENTON SWDM), RENTON MUNICIPAL CODE ( RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION ( APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 4.APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION ( E.G. WATER, SEWER, GAS, ELECTRICAL. ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY. 5.A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6.THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANT' S CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS- BUILT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A CONFLICT EXISTS. 7.VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 ( WA STATE PLANE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY. REFERENCE BENCHMARK, DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS. 8.ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DRY DENSITY PER SECTION 2-03.3(14)D - COMPACTION AND MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS, ALL TRENCH BACKFILL SHALL BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92% OF MAXIMUM DRY DENSITY. 9.OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS. 10.ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED. 11.ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE CITY. 12.ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220. 00, 220. 10, AND 220. 20. 13.STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2, OR 5 INSIDE AND OUTSIDE. 14.ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT- LOCKING LIDS PER THE CITY STANDARD PLAN 204. 10, 204. 20, 204. 30, 204. 40, AND 204. 50. STRUCTURES SHALL HAVE: ·RECTANGULAR OR ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE ROADWAY. ·ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURB/ GUTTER LINE. ·ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT- OF- WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT- OF- WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO. 15.BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDM. 16.LIDS OF MANHOLES/ CATCH BASINS WITHIN PUBLIC RIGHT- OF- WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLE/ CATCH BASIN RIMS SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN. 17.ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT- OF- WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. 18.ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1) FOOT AND SHALL MEET THE FOLLOWING SPECIFICATIONS: •4 - 8 INCH ROCK / 40 - 70% PASSING; •2 - 4 INCH ROCK / 30 - 40% PASSING; AND •LESS THAN 2 INCH ROCK / 10 - 20% PASSING. 19.FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON- SITE BMPS. 20.THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH A BOLT- LOCKING LID MARKED " STORM” OR " DRAIN" SHALL BE LOCATED AT THE PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227. 00. 21.ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED TO THE CITY PRIOR TO CONSTRUCTION. 22.ALL NEWLY- INSTALLED AND NEWLY- REHABILITATED ( PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 266. 00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS AND/ OR PAVEMENT. 23.ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED. 24.FOR ALL DISTURBED PERVIOUS AREAS ( COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 264. 00. 25.ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION AND/ OR LIABILITY CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM SYSTEM PROVIDED DURING CONSTRUCTION. 26.ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED RIGHT- OF- WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY. 27.PROJECTS LOCATED WITHIN THE CITY' S AQUIFER PROTECTION AREA ( APA) SHALL COMPLY WITH SPECIAL REQUIREMENT # 6 OF THE RENTON SWDM AND AQUIFER PROTECTION REGULATIONS ( RMC 4-3-050). 28.PLACEMENT OF SURFACE APPURTENANCES ( CATCH BASIN/ MANHOLE LIDS, CLEANOUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON- SLIP OR NON- SKID LID PER ADA REQUIREMENTS. 29.CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT. 30.MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE RENTON SWDM. 31.CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE, THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDUCTED. FOR LARGE AREAS ( E.G., PARKING AREAS), TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781. R-433403 2025-07-15 DEVELOPMENT ENGINEERING msippo 08/13/2025 NOTESCall 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 CONTRACTOR IS ALERTED TO THE FACT THAT WORK WILL BE ACCOMPLISHED AROUND ACTIVE PSE GAS AND ENERGIZED FACILITIES THAT ARE SERVING EXISTING CUSTOMERS. CONTRACTOR SHALL COORDINATE WITH PSE TO DETERMINE WHICH FACILITIES ARE ACTIVE AND ENERGIZED AND SHALL IMPLEMENT SAFETY PROCEDURES PER PSE REQUIREMENTS. CONTRACTOR SHALL COORDINATE WITH PSE TO ENSURE THAT FACILITIES ARE IN PLACE TO MAINTAIN SERVICE TO CUSTOMERS THROUGHOUT CONSTRUCTION. AD AREA DRAIN AVE AVENUE CB CATCH BASIN CL CENTER LINE COR CITY OF RENTON CSBC CRUSHED SURFACE BASE COURSE DEMO DEMOLISH DI DUCTILE IRON ELECT ELECTRICAL EL/ELEV ELEVATION EX/EXIST EXISTING FD FRENCH DRAIN FH FIRE HYDRANT GB GRADE BREAK GI GREASE INTERCEPTOR HMA HOT MIX ASPHALT IE INVERT ELEVATION IRR IRRIGATION LF LINEAR FOOT LS LANDSCAPE/LANDSCAPING MAX MAXIMUM MIN MINIMUM NTS NOT TO SCALE PLUMB PLUMBING POC POINT OF CONNECTION ROW RIGHT OF WAY SD STORE DRAIN SS SANITARY SEWER STD STANDARD TYP TYPICAL W WATER #NUMBER ABBREVIATIONS:BASIS OF DESIGN: CIVIL DESIGN IS BASED ON THE FOLLOWING DOCUMENTS: TOPOGRAPHIC SURVEY PROVIDED BY KPG PSOMAS, DATED 2025-04-03 ARCHITECTURAL BACKGROUNDS PROVIDED BY GRAHAM BABA ARCHITECTS LANDSCAPE BACKGROUNDS PROVIDED BY HEWITT GEOTECHNICAL CONDITIONS DOCUMENTED IN GEOTECHNICAL REPORT BY ASSOCIATED EARTH SCIENCES, DATED 2024-10-31 R-433404 PROVIDE KC METRO A MINIMUM 30 DAY NOTICE BEFORE CONSTRUCTION BEGINS. CONTACT DAVE KORTHALS – SOUTHEAST DISTRICT PLANNER - TRANSIT ROUTE FACILITIES - MOBILITY DIVISION – TRANSIT DEPARTMENT 201 S. JACKSON ST. - MS: KSC-TR-0413 - SEATTLE, WA 98104-3856 206-477-5776 LEGEND: LIMITS OF WORK RIGHT-OF-WAY LINE STORM DRAINAGE PIPE (SD) ROOF DRAIN (RD) FRENCH DRAIN (FD) TRENCH DRAIN (TD) SANITARY SEWER PIPE (SS) FLOW DIRECTION LIGHTING CONDUIT (ELEC) AREA DRAIN (AD) CATCH BASIN (CB), TYPE 1 CLEANOUT (SSCO, SDCO, CO) PIPE FLOW DIRECTION PEDESTRIAN CONCRETE PAVEMENT VEHICULAR CONCRETE PAVEMENT EXISTING CONCRETE PAVEMENT PERMEABLE SURFACING AT EXISTING TREE, REFER TO LS PLANS PERMEABLE SURFACING AT PROPOSED TREE, REFER TO LS PLANS LANDSCAPING, REFER TO LS PLANS FLUSH CURB VERTICAL CURB REMOVABLE BOLLARD, REFER TO LS PLANS 2025-07-15 DEVELOPMENT ENGINEERING msippo 08/13/2025 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 1 C2.50 2 C2.50 4 C2.50 3 C2.50 S 3RD ST BU R N E T T A V E S RENTON MARKET PARCEL #5696000055 LO G A N A V E S PARCEL #5696000050 SP U P A R C E L #0 0 0 7 2 0 - 0 1 8 8 DEMO EXIST CURB, TYP PROTECT EXIST STREET LIGHT TO REMAIN, TYP PROTECT ELEC, COMM, AND WATER INFRASTRUCTURE SAWCUT PAVEMENT FOR DRIVEWAY AND BOLLARDS PROTECT EXIST POWER, TYP PROTECT EXIST GAS LINE, TYP PROTECT EXIST BUILDING AND FOUNDATION, TYP SAWCUT PAVING FOR SOUTH ENTRY VESTIBULE, REFER TO ARCH PLAN FOR LIMITS EXIST RENTON TRANSIT CENTER REMOVE STRIPING AND SIGNAGE FOR EVENT PARKING STALLS. RELOCATE EVENT PARKING SIGNAGE. DEMO EXIST DRAIN AND ASSOCIATED SD PIPES, TEMPORARILY REROUTE FLOWS AS NEEDED REMOVE STRIPING FOR PARKING STALLS, TYP PROTECT EXIST PARKING SIGNAGE, UNLESS OTHERWISE NOTED PROTECT EXIST EVENT PARKING SIGNAGE, AND AUTHORIZED VEHICLE SIGNAGE. RELOCATE 2HR PARKING SIGNAGE REFER TO C3.00 CAP PIPE, TYP LIMITS OF WORK, TYP RIGHT-OF-WAY LINE, TYP REMOVE BOLLARDS SAWCUT TO THE NEAREST JOINT, TYP PROTECT EXIST FOUNTAIN STRUCTURE AND STONE WALLS, REFER TO LS PLAN FOR DETAILS EXIST CONCRETE PAVING TO REMAIN, TYP CATCH BASIN INSERT, TYP PROTECT EXIST FH, TYP PROTECT EXIST WATER METER AND INFRASTRUCTURE STRAW WATTLE, TYP EXIST WATER FEATURE TO BE DEMOLISHED. CUT AND CAP WATER SUPPLY AND DRAINS FOR THE EXIST WATER FEATURE. REMOVE ALL ASSOCIATED UTILITY VAULTS. PROTECT EXIST SITE WALL AND ASSOCIATED LANDSCAPE BOULDERS, REFER TO LS PLANS FOR DETAILS CUT AND CAP WATER SUPPLY AND DRAINS FOR THE EXIST WATER FEATURE EXIST DRINKING FOUNTAIN TO BE SALVAGED AND REUSED, REFER TO SHEET C3.01 AND LS PLAN PROTECT SPU MAINS AND ASSOCIATED VAULTS, TYP SAWCUT TO THE NEAREST JOINT, TYP PROTECT EXIST ELECT, LIGHTING, AND CONDUITS UNLESS NOTED TO BE DEMOLISH ON ELECT PLANS, TYP REFER TO LS FOR LS DEMO, TYP RETIRE AND REMOVE EXIST WATER METER. CAP EXIST WATER SERVICE. REMOVE EXIST LIGHT POLES AND ASSOCIATED HH'S. PROTECT CONTINUATION OF CONDUITS FOR LIGHTING TO REMAIN. 1 1 1 TEMPORARY CONSTRUCTION FENCE STOCKPILE AREA NORTH CONSTRUCTION ACCESS WITH WHEEL WASH CONSTRUCTION ACCESS WITH WHEEL WASH PROTECT EXIST UTILITIES, SIDEWALK, CURB, AND ROADWAY DEMO AND CAP EXIST SS PIPE REFER TO LS PLANS FOR TREE PROTECTION, TYP EXIST TRANSIT STATION ADA STALL TO REMAIN, PROTECT STRIPING AND SIGNAGE PROTECT EXIST WATER METER AND INFRASTRUCTURE, TYP CAP AND DEMOLISH SS UPSTREAM FROM PROP WATER DRINKING FOUNTAIN POC Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 0 1 inch = 20 feet 10'20'40' LEGEND: DEMO AND TESC PLAN R-433405 RIGHT-OF-WAY LINE LIMITS OF WORK STRAW WATTLE TEMPORARY CONSTRUCTION FENCE CATCH BASIN INSERT SAWCUT LINE REMOVE EXISTING STRUCTURE DEMOLISH EXISTING CURB DEMOLISH EXISTING UTILITY DEMOLITION NOTES: 1 REMOVE AND DEMOLISH AREA DRAIN AND ASSOCIATED STORM DRAINAGE PIPES.NOTES: 1.REFER TO C1.00 TO C1.02 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS. REFER TO LANDSCAPE PLANS FOR TREE REMOVAL AND TREE PROTECTION. REFER TO ELECTRICAL FOR LIGHTING DEMOLITION. 2.CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF ALL UTILITIES AND CONDUCT EXISTING BUILDING/SITE PRE-CONSTRUCTION SURVEYS NECESSARY, PRIOR TO DEMOLITION OR CONSTRUCTION ACTIVITIES. 3.PROTECT ALL UTILITIES AND SURFACE IMPROVEMENTS ONSITE, WITHIN THE RIGHT OF WAY, AND ON ADJOINING PROPERTIES UNLESS OTHERWISE NOTED. DEMOLISH OR ABANDON UTILITIES, AS NOTED ON PLAN, PER COR STANDARD REQUIREMENTS. 4.CONTRACTOR SHALL OBTAIN AND PAY FOR NECESSARY PERMITS TO EXECUTE DEMOLITION, INCLUDING PERMIT TO USE PUBLIC WATER SUPPLY FOR DUST SUPPRESSION. 5.CONTRACTOR SHALL PROVIDE TRAFFIC AND PEDESTRIAN REROUTES AND CONTROL AS NECESSARY TO COMPLETE THE WORK, AND OBTAIN APPROVAL FROM THE CITY PRIOR TO BEGINNING WORK. 6.CONTRACTOR IS RESPONSIBLE FOR PREVENTING SEDIMENT AND SEDIMENT-LADEN RUNOFF FROM LEAVING THE SITE AND SHALL INSTALL, MAINTAIN, AND UPGRADE EROSION AND SEDIMENT CONTROL (ESC) FACILITIES AND BMPS AS NECESSARY TO ADDRESS FIELD CONDITIONS, STORM EVENTS, AND THE PROGRESSION OF WORK DURING THE CONSTRUCTION PERIOD. THE ESC FACILITIES SHOWN ON THE PLANS ARE THE MINIMUM REQUIREMENTS FOR ANTICIPATED SITE CONDITIONS; THESE MEASURES SHALL BE AMENDED, RELOCATED, AND/OR UPGRADED AS NEEDED, INCLUDING THE ADDITION OF PUMPS IF NECESSARY, TO PREVENT SEDIMENT AND SEDIMENT-LADEN WATER FROM LEAVING THE SITE AND TO PREVENT EROSION AND DAMAGE TO SUBGRADE. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH COR REQUIREMENTS. 7.FENCE LIMITS SHOWN ARE APPROXIMATE AND SHALL BE ADJUSTED AS NECESSARY FOR THE CONTRACTOR TO ACCOMPLISH THE WORK. PREVENT DISTURBANCE AND DAMAGE BEYOND THE LIMITS OF WORK. 8.STORMWATER RUNOFF AND DEWATERING FLOWS, IF GENERATED, SHALL BE DIRECTED TO TEMPORARY PUMPS FOR CONVEYANCE TO TREATMENT SYSTEM. CONTRACTOR SHALL FIELD LOCATE AND SIZE PUMPS TO ACCOMMODATE FLOWS ENCOUNTERED. CONTRACTOR SHALL SUPPLY BACKUP PUMPS AS NEEDED. 9.FOR THE CATCH BASINS THAT ARE TO BE REMOVED, PROVIDE CATCH BASIN/INLET PROTECTION UP UNTIL THEY ARE REMOVED. 10.CONTRACTOR SHALL PROVIDE COVER AND CONTAINMENT TO PROTECT DOWNSTREAM SYSTEMS AND SOILS FROM POLLUTANTS GENERATED DURING, AND AS A RESULT OF CONSTRUCTION ACTIVITIES, AND PREVENT SEDIMENT AND POLLUTANTS FROM LEAVING THE SITE. 11.ALL TEMPORARY STOCKPILES, CUT SLOPES, AND FILL SLOPES SHALL BE PROTECTED WITH PLASTIC SHEETING, UNLESS STABILIZED BY OTHER APPROVED METHODS. 12.REMOVE AND DISPOSE OF ALL TESC MEASURES AT THE COMPLETION OF THE PROJECT WHEN ALL DISTURBED AREAS HAVE BEEN FULLY STABILIZED IN FINAL CONDITION. 13.CITY STREETS AND SIDEWALKS SHALL BE KEPT CLEAN AT ALL TIMES. MATERIAL SHALL NOT BE STORED WITHIN THE RIGHT-OF-WAY, ON CITY STREETS OR SIDEWALKS WITHOUT A STREET USE PERMIT FROM THE COR. 14.DEMOLITION SHALL BE IN CONFORMANCE WITH APPLICABLE REGULATIONS, CODES, AND DEMOLITION PERMIT REQUIREMENTS. 15.CONTRACTOR SHALL DISPOSE OF EXCESS DEMOLITION MATERIAL OFF-SITE IN A SAFE AND LEGAL MANNER IN ACCORDANCE WITH APPLICABLE JURISDICTIONS. 16.MAKE VERTICAL SAWCUTS BETWEEN ALL EXISTING PAVEMENT TO REMAIN AND THE PORTION TO BE REMOVED AND PROTECT PAVEMENT TO REMAIN. REPLACE ANY DAMAGED IMPROVEMENTS IN KIND. PRIOR TO SAWCUTTING, CONTRACTOR SHALL SUBMIT A CUTTING AND JOINTING PLAN FOR ALL PAVEMENT BEING DISTURBED. 17.ANY DAMAGE RESULTING FROM PROJECT CONSTRUCTION ACTIVITIES TO EXISTING IMPROVEMENTS OR VEGETATION OUTSIDE OF WORK INDICATED ON PLAN SHALL BE REPAIRED/REPLACED IN KIND AT CONTRACTOR'S EXPENSE AND IN A TIME FRAME DICTATED BY THE OWNER. 18.IF EXISTING IMPROVEMENTS ARE DISTURBED WITHIN THE RIGHT-OF-WAY BY CONSTRUCTION ACTIVITY, REPLACE PER COR STANDARDS AND PROJECT PLANS AT CONTRACTOR'S EXPENSE. 19.CONTRACTOR SHALL COORDINATE WITH ALL AFFECTED UTILITY PROVIDERS AND CITY TO CONFIRM SYSTEMS ARE NOT ENERGIZED, TO KEEP ADJOINING PROPERTY SERVICES UNINTERRUPTED, AND TO PERFORM DEMOLITION ACTIVITIES IN ACCORDANCE TO APPLICABLE STANDARDS. 20.REMOVE STRIPING ON REMAINING EXISTING PAVEMENT TO INSTALL FULL EXTENTS OF PROPOSED STRIPING AS INDICATED ON PLANS. REMOVAL OF EXISTING STRIPING SHALL NEGATIVELY IMPACTING EXISTING PAVEMENT TO REMAIN. 21.CONTRACTOR SHALL COORDINATE WITH OWNER FOR EXISTING ITEMS TO BE SALVAGED. SALVAGED ITEMS SHALL BE PROTECTED AND STORED IN LOCATION ON-SITE, OR AT AN AGREED TO LOCATION, PER OWNER DIRECTION. IF SALVAGED ITEMS ARE TO BE RELOCATED, INSTALL SALVAGED ITEMS WITHIN LIMIT OF WORK WHERE NOTED ON PLANS. REFER TO LANDSCAPE PLANS FOR ADDITIONAL ITEMS TO BE SALVAGED. REMOVE FULL DEPTH CONCRETE PAVING OR LANDSCAPING REMOVE EXISTING SITE WALL, REFER TO LS PLANS LANDSCAPE REMOVAL, REFER TO LS PLANS TREE PROTECTION, REFER TO LS PLANS 1 1 2025-09-15 DEVELOPMENT ENGINEERING msippo 10/02/2025 Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 1CATCH BASIN INSERT NTS 2STRAW WATTLE NTS DEMO AND TESC DETAILS R-433406 6' - 0 " 8'-0" MIN 12'-0" MAX TWISTED SELVAGE TOP AND BOTTOM NOTES: 1.CHAINLINK FABRIC TO BE MIN 11 GAUGE, GALVANIZED. NO RUSTED OR EXCESSIVELY MALFORMED FABRIC. 2.FENCE BASES SHALL BE OF SUFFICIENT WEIGHT AND/OR SPREAD TO ADEQUATELY SUPPORT EACH PANEL. 3.PANEL-TO-PANEL CONNECTIONS SHALL BE MADE AT A MIN TWO LOCATIONS PER CONNECTION UNLESS OTHERWISE APPROVED. 4.INSTALL 11'-8" X 5'-6" MESH CONSTRUCTION SCRIM PER FENCE PANEL AND/OR CONSTRUCTION WARNING SIGN 50' OC BASED ON CONSTRUCTION GRAPHIC PLAN. 4 TEMPORARY CONSTRUCTION CHAINLINK FENCE DETAIL NTS 3CONSTRUCTION ENTRANCE NTS 2025-07-15 DEVELOPMENT ENGINEERING msippo 08/13/2025 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 1 C3.11 LO G A N A V E S BU R N E T T A V E S 10+00 11+00 12+00 12+87.13 20 . 5 ' RENTON MARKET 55.0' 22.0'± EXIST SIDE SEWER, REFER TO ADD ALT #2 EXIST MH RIM 35.59 6" IE 31.7 E,N @ CL REMOVABLE BOLLARD, REFER TO LS PLAN TEMPORARY ENCLOSURE, REFER TO ARCH PLAN DRIVEWAY ENLARGEMENT EXIST RENTON TRANSIT CENTER EXIST BUILDING, TYP EXIST TRANSIT CENTER ADA PARKING STALL, APPROXIMATE LOCATION. PROTECT EXIST ADA STALL, SIGN AND STRIPING . SERVICE VEHICLE EGRESS, RIGHT TURN ONLY VEHICLE INGRESS AND EGRESS WORK LIMITS, TYP UNMARKED LOADING ZONE RIGHT-OF-WAY LINE TYP REMOVABLE BOLLARD MOUNTING BASE PLATE, REFER TO LS PLAN 1 C3.12 SIDE SEWER ENLARGEMENT 3 C3.20SS LINE 10 EXIST SS CO AND SIDE SEWER, REFER TO ADD ALT #2 SS CO, TYP 3 C4.50RESTRIPE EXIST PARKING STALLS. PROTECT EXIST PARKING SIGNAGE, UNLESS OTHERWISE NOTED ON C2.00 RELOCATE EXIST EVENT CENTER SIGN, REUSE EXIST POLE RELOCATE EXIST 2 HR PARKING SIGN TO EXIST LIGHT POLE RELOCATE EXIST EVENT CENTER PARKING SIGN, INSTALL NEW POLE. FIXED BOLLARD TYP EXIST 4" FIRE SPRINKLER SUPPLY LINE, PER COR EXIST 1" LS IRRIGATION WATER METER, PER COR EXIST 1.5" LS DOMESTIC WATER METER, PER COR NOTES: 1.REFER TO C1.00 TO C1.02 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS. REFER TO C3.00 FOR CIVIL IMPROVEMENT'S LEGEND AND NOTES. 2.CONTRACTOR SHALL CONFIRM POC'S PRIOR TO CONSTRUCTION WHEN CONNECTING TO EXISTING SYSTEMS AND NOTIFY ENGINEER OF ANY DISCREPANCIES. PRIOR TO CONSTRUCTION, FIELD VERIFY DOWNSTREAM INVERTS FOR ALL EXISTING SS AND SD PIPES, AREA DRAINS AND CATCH BASINS WITH PROPOSED UPSTREAM CONNECTIONS. CONFIRM EXISTING OUTLET INVERTS PROVIDE POSITIVE DRAINAGE FOR ALL UPSTREAM PIPES. PIPES SHALL BE VERIFIED WITH DYE TEST, CCTV, OR OTHER METHOD COORDINATED AND APPROVED BY CITY OF RENTON. COORDINATE TESTING WITH CITY. 3.PROJECT ASSUMES THAT ALL CITY EXISTING UTILITY INFRASTRUCTURE IS ADEQUATELY SIZED TO SUPPORT THE PROJECT. 4.PRIOR TO DEMOLITION, CONTRACTOR SHALL FIELD VERIFY AND LOCATE ALL EXISTING UTILITIES TO REMAIN WITHIN AND ADJACENT TO LIMIT OF WORK. 5.ALL EXISTING PAVEMENT STRIPING DISTURBED DURING CONSTRUCTION SHALL BE REPLACED IN KIND. PRODUCTS SHALL BE PER CITY OF RENTON PUBLIC WORKS DEPARTMENT STANDARD PLANS AND SPECIFICATIONS, AND WSDOT STANDARD PLANS AND SPECIFICATIONS. CONTRACTOR SHALL SUBMIT A PAVEMENT RESTORATION PLAN INCLUDING, CUTTING AND JOINTING, FOR ALL PAVEMENT BEING DISTURBED. 6.FULL DEPTH PAVEMENT REPLACEMENT, AND TRENCH RESTORATION AT UTILITY CUTS, SHALL BE PER CITY OF RENTON STD DETAILS. PAVEMENT SECTION SHALL BE PER CITY OF RENTON STD DETAILS, OR MATCH EXISTING WHICHEVER IS GREATER. MATCH EXISTING PAVEMENT MATERIAL PER ASSOCIATED STANDARD DETAILS. TRENCH AND BACKFILL SHALL BE PER CITY OF RENTON RENTON STD. PLAN 220.20. PEDESTRIAN CONCRETE PAVEMENT SHALL BE PER CITY OF RENTON STD. PLAN 102. VEHICULAR CONCRETE PAVING SHALL BE PER CITY OF RENTON RENTON STD. PLAN 110, 110.1 AND 111 AND PROJECT DETAILS. 7.PEDESTRIAN CONCRETE, MINIMUM SECTION: 4" CONCRETE 6" CSBC REFER TO LANDSCAPE FOR CONCRETE SCORING, COLOR, AND FINISHES. 8.THE RENTON MARKET AND PIAZZA PROJECT IS REQUIRED TO MEET STORMWATER REQUIREMENTS PER THE 2022 CITY OF RENTON SURFACE WATER DESIGN MANUAL (RSWDM). 8.1.FLOW CONTROL: THE PROJECT PROPOSES MORE THAN 5,000 SQUARE FEET OF NEW PLUS REPLACED IMPERVIOUS SURFACE AND IS LOCATED IN THE PEAK FLOW RATE CONTROL STANDARD AREA. TARGET SURFACES DO NOT GENERATE MORE THAN A 0.15-CFS INCREASE IN THE EXISTING SITE CONDITIONS 100-YR PEAK FLOW, THEREFORE FLOW CONTROL IS NOT REQUIRED. 8.2.WATER QUALITY: THE PROJECT PROPOSES LESS THAN 5,000 SQUARE FEET OF NEW PLUS REPLACED IMPERVIOUS SURFACE (PGIS), AND LESS THAN ¾ ACRES OF POLLUTANT GENERATION PERVIOUS SURFACE (PGPS), THEREFORE WATER QUALITY IS NOT REQUIRED. 8.3.ON-SITE BMPS: THE PROJECT PROPOSES MORE THAN 2,000-SF OF NEW PLUS IMPERVIOUS SURFACE, THEREFORE ON-SITE STORMWATER MANAGEMENT (OSM) IS REQUIRED. ALL AVAILABLE OSM BMP'S WERE EVALUATED AND ARE NOT FEASIBLE FOR THE SITE. 8.4.THE PROJECT IS LOCATED IN AN AQUIFER PROTECTION AREA, THEREFORE STORMWATER MITIGATION FACILITIES SHALL NOT INFILTRATE AND SHALL BE COLLECTED VIA STORMWATER CONVEYANCE AND DISCHARGE TO THE CITY MAIN. 9.GREASE INTERCEPTOR SIZE AND VAULT PER MECHANICAL. 10.ELECTRICAL SERVICE FOR THE SITE IS PER ELECTRICAL. 11.STORM, SEWER, AND WATER INFRASTRUCTURE SHALL BE PER CITY OF RENTON STANDARDS AND WSDOT STANDARD SPECIFICATIONS, UNLESS OTHERWISE NOTED. 12.STORM DRAINAGE PIPE MATERIAL SHALL BE PER RSWDM TABLE 4.2.1.A2, UNLESS OTHERWISE NOTED. 13.ALL REGULATORY SIGNAGE AND PAVEMENT STRIPING SHALL CONFORM TO CITY OF RENTON AND MUTCD SPECIFICATIONS. Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 0 1 inch = 20 feet 10'20'40' ADDITIVE ALTERNATE #2: SIDE SEWER REPLACEMENT EXISTING SS CO ELEVATION TO BE FIELD VERIFIED. A CCTV INSPECTION OF THE EXISTING SIDE SEWER IS REQUIRED TO SURVEY CONDITION OF PIPE. A CIPP LINER MAY BE REQUIRED DEPENDING ON THE CONDITION OF THE PIPE. IF EXISTING SS CO IS AT AN ELEVATION THAT PROVIDES POSITIVE DRAINAGE OUT OF THE SITE (EXISTING SS PIPE MUST BE AT MIN 2.0% OR APPROVED BY THE CITY) AND ALLOWS FOR THE ONSITE GREASE INTERCEPTOR PIPING TO BE INSTALLED AT A 1.0% MINIMUM SLOPE, AND EXISTING PIPE IS IN SUFFICIENT CONDITION THEN EXISTING SS MAY BE USED. IF SIDE SEWER REPLACEMENT IS REQUIRED, NEW PIPE, CLEANOUT, AND PAVEMENT RESTORATION (INCLUDING FULL CONCRETE PANEL REPLACEMENT), SHALL BE PER COR STANDARDS. CIVIL IMPROVEMENT PLAN R-433407 REFER TO SHEET C3.01 FOR CONTINUATION REFER TO SHEET C3.02 FOR CONTINUATION 2025-07-15 DEVELOPMENT ENGINEERING msippo 08/13/2025 WATER UTILITY ABDOUL GAFOUR 08/13/2025 • • • • • • • • • • • • • • • • 37.8 37. 6 37 . 4 37 . 2 37 . 0 36 . 8 36 . 6 36. 8 37. 0 37. 2 3 7 . 4 37. 2 37.4 37.6 37.8 37.6 37.6 37.4 37.2 37.0 36.8 3 C3.51 1 C3.20 2 C3.20 1 C3.10 37 20+00 21+00 PARCEL #5696000050 LO G A N A V E S SP U P A R C E L #0 0 0 7 2 0 - 0 1 8 8 3 7 S 3RD ST 8" SD, TYP 17 . 9 ' ± RIGHT-OF-WAY LINE, TYP PROP LANDSCAPING, REFER TO LS PLAN, TYP PROP SITE SEATING, TYP REFER TO LS PLANS CLEAN OUT (CO) 4" IE 35.2 0UT, NE AD 10 (EXIST) ADJUST RIM TO FG PROP LIGHTING ROUTING (2)-1" PVC CONDUIT (2)-3 4" PVC CONDUIT REFER TO ELEC PLANS PROP LIGHTING ROUTING (2)-3 4" PVC CONDUITS (2)-1" PVC CONDUITS REFER TO ELEC PLANS INTERCEPT EXIST 3/4" CONDUIT REFER TO ELEC PLANS INTERCEPT EXIST 3 4" CONDUIT TO SERVICE PROP LIGHT REFER TO ELEC PLANS PROP ELEC ENCLOSURE REFER TO ELEC PLANS MATCH EXIST GRADES, TYP REFER TO LS PLANS FOR SOFTSCAPE GRADING, TYP AD 11 CO 4" IE 35.48 0UT, NW AD 12 PROP LIGHT POLE, REFER TO LS AND ELEC PLAN, TYP CONNECT TO EXIST CB EXIST RIM 35.58 ± 8" IE IN 33.6 ± (N) EX 12" IE IN 33.6 ± (E) EX 12" IE OUT 33.6 ± (S) SDCB 100 AD 20 AD 13 RIM 37.55± 4" IE IN 35.0 (NE) 4" IE OUT 35.0(SE) 66" SPU WATER MAIN 52" SPU WATER MAIN ELECTROLYSIS TEST STATION, PER CITY OF SEATTLE STD PLAN 360. REROUTE EXIST SPU ELECTROLYSIS TEST STATIONS CONDUIT AND WIRING TO PROP LOCATION. COORDINATE WITH SPU. PROTECT EXIST SPU CATHODIC PROTECTION RECTIFIER, TYP SD LINE 10 SD LINE 20 CONTRACTOR SHALL COORDINATE WITH SPU PRIOR TO AND DURING ANY CONSTRUCTION WITHIN THE SPU PARCEL 12" SPU WATER MAIN MATCH EXIST GRADES, TYP SOUTH ENTRY ENLARGEMENT PEDESTRIAN CONCRETE PAVING, REFER TO NOTE 7, TYP 1 C3.13 PIAZZA PARK PIAZZA PARK GRADING ENLARGEMENT WEST LIMITS OF WORK, TYP 1 C3.51 4" FRENCH DRAIN (FD), TYP SLOPE @ 0.5% MIN PROP PERMEABLE SURFACING AT EXIST TREE, TYP EXIST CONCRETE PAVING TO REMAIN, TYP PROP FLUSH CONCRETE CURB, TYP 2 C4.50 PROP PERMEABLE SURFACING AT PROP TREE, TYP 2 C4.50 PROP VEHICULAR PAVING, CONCRETE PANEL REPLACEMENT, TYP. REFER TO NOTE 6. PROP FACE OF CONCRETE TRAFFIC CURB, PER COR STD PLAN 101 1 C4.50 PARCEL #5696000055RELOCATE EXIST WATER DRINKING FOUNTAIN, LOCATE PER LS PLAN CONNECT DOMESTIC WATER, AND SS SERVICE TO EXIST ONSITE INFRASTRUCTURE. MATCH EXIST SERVICE SIZES FOR FOUNTAIN. REFER TO NOTE 2. 4.0' LO G A N A V E S SSCO, TYP 2 C3.50 EXIST 1" LS IRRIGATION WATER METER, PER COR 1" DCVA, REFER TO LS PLANS 1 1 PROP ELEC POC (1) 2" PVC CONDUIT LS ELEC RECEPTACLE, CONNECT TO EXIST CONDUIT, REFER TO LS AND ELEC PLANS PROP LIGHT POLE POC, TYP ELEC JUNCTION BOX, TYPE 1 PER COR STD PLAN 119 AND 120, AND WSDOT STD PLAN J-40.10-04(1) 2" PVC CONDUIT, REFER TO ELEC PLANS PROP LIGHTING ROUTING (1) 2" PVS CONDUIT, REFER TO ELEC PLANS 1 NOTES: 1.REFER TO C1.00 TO C1.02 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS. REFER TO C3.00 FOR CIVIL IMPROVEMENT'S LEGEND AND NOTES. 2.CONTRACTOR SHALL CONFIRM POC'S PRIOR TO CONSTRUCTION WHEN CONNECTING TO EXISTING SYSTEMS AND NOTIFY ENGINEER OF ANY DISCREPANCIES. PRIOR TO CONSTRUCTION, FIELD VERIFY DOWNSTREAM INVERTS FOR ALL EXISTING SS AND SD PIPES, AREA DRAINS AND CATCH BASINS WITH PROPOSED UPSTREAM CONNECTIONS. CONFIRM EXISTING OUTLET INVERTS PROVIDE POSITIVE DRAINAGE FOR ALL UPSTREAM PIPES. PIPES SHALL BE VERIFIED WITH DYE TEST, CCTV, OR OTHER METHOD COORDINATED AND APPROVED BY CITY OF RENTON. COORDINATE TESTING WITH CITY. CONFIRM DRINKING FOUNTAIN IS CONNECT TO EXIST DOMESTIC WATER SUPPLY PRIOR TO INSTALLATION. 3.PROJECT ASSUMES THAT ALL CITY EXISTING UTILITY INFRASTRUCTURE IS ADEQUATELY SIZED TO SUPPORT THE PROJECT. 4.PRIOR TO DEMOLITION, CONTRACTOR SHALL FIELD VERIFY AND LOCATE ALL EXISTING UTILITIES TO REMAIN WITHIN AND ADJACENT TO LIMIT OF WORK. 5.ALL EXISTING PAVEMENT STRIPING DISTURBED DURING CONSTRUCTION SHALL BE REPLACED IN KIND. PRODUCTS SHALL BE PER CITY OF RENTON PUBLIC WORKS DEPARTMENT STANDARD PLANS AND SPECIFICATIONS, AND WSDOT STANDARD PLANS AND SPECIFICATIONS. CONTRACTOR SHALL SUBMIT A PAVEMENT RESTORATION PLAN INCLUDING, CUTTING AND JOINTING, FOR ALL PAVEMENT BEING DISTURBED. 6.FULL DEPTH PAVEMENT REPLACEMENT, AND TRENCH RESTORATION AT UTILITY CUTS, SHALL BE PER CITY OF RENTON STD DETAILS. PAVEMENT SECTION SHALL BE PER CITY OF RENTON STD DETAILS, OR MATCH EXISTING WHICHEVER IS GREATER. MATCH EXISTING PAVEMENT MATERIAL PER ASSOCIATED STANDARD DETAILS. TRENCH AND BACKFILL SHALL BE PER CITY OF RENTON RENTON STD. PLAN 220.20. PEDESTRIAN CONCRETE PAVEMENT SHALL BE PER CITY OF RENTON STD. PLAN 102. VEHICULAR CONCRETE PAVING SHALL BE PER CITY OF RENTON RENTON STD. PLAN 110, 110.1 AND 111 AND PROJECT DETAILS. 7.PEDESTRIAN CONCRETE, MINIMUM SECTION: 4" CONCRETE 6" CSBC REFER TO LANDSCAPE FOR CONCRETE SCORING, COLOR, AND FINISHES. 8.THE RENTON MARKET AND PIAZZA PROJECT IS REQUIRED TO MEET STORMWATER REQUIREMENTS PER THE 2022 CITY OF RENTON SURFACE WATER DESIGN MANUAL (RSWDM). 8.1.FLOW CONTROL: THE PROJECT PROPOSES MORE THAN 5,000 SQUARE FEET OF NEW PLUS REPLACED IMPERVIOUS SURFACE AND IS LOCATED IN THE PEAK FLOW RATE CONTROL STANDARD AREA. TARGET SURFACES DO NOT GENERATE MORE THAN A 0.15-CFS INCREASE IN THE EXISTING SITE CONDITIONS 100-YR PEAK FLOW, THEREFORE FLOW CONTROL IS NOT REQUIRED. 8.2.WATER QUALITY: THE PROJECT PROPOSES LESS THAN 5,000 SQUARE FEET OF NEW PLUS REPLACED IMPERVIOUS SURFACE (PGIS), AND LESS THAN ¾ ACRES OF POLLUTANT GENERATION PERVIOUS SURFACE (PGPS), THEREFORE WATER QUALITY IS NOT REQUIRED. 8.3.ON-SITE BMPS: THE PROJECT PROPOSES MORE THAN 2,000-SF OF NEW PLUS IMPERVIOUS SURFACE, THEREFORE ON-SITE STORMWATER MANAGEMENT (OSM) IS REQUIRED. ALL AVAILABLE OSM BMP'S WERE EVALUATED AND ARE NOT FEASIBLE FOR THE SITE. 8.4.THE PROJECT IS LOCATED IN AN AQUIFER PROTECTION AREA, THEREFORE STORMWATER MITIGATION FACILITIES SHALL NOT INFILTRATE AND SHALL BE COLLECTED VIA STORMWATER CONVEYANCE AND DISCHARGE TO THE CITY MAIN. 9.GREASE INTERCEPTOR SIZE AND VAULT PER MECHANICAL. 10.ELECTRICAL SERVICE FOR THE SITE IS PER ELECTRICAL. 11.STORM, SEWER, AND WATER INFRASTRUCTURE SHALL BE PER CITY OF RENTON STANDARDS AND WSDOT STANDARD SPECIFICATIONS, UNLESS OTHERWISE NOTED. 12.STORM DRAINAGE PIPE MATERIAL SHALL BE PER RSWDM TABLE 4.2.1.A2, UNLESS OTHERWISE NOTED. 13.ALL REGULATORY SIGNAGE AND PAVEMENT STRIPING SHALL CONFORM TO CITY OF RENTON AND MUTCD SPECIFICATIONS. 14.LOCATION AND DEPTH OF EXISTING SPU WATER MAINS (TRANSMISSION PIPE LINES) IS APPROXIMATE. 14.1.SPU SHALL BE NOTIFIED AND ONSITE WHILE CONTRACTOR PERFORMS ANY CONSTRUCTION WITHIN THE SPU PARCEL. SPU SHALL BE NOTIFIED AT LEAST 3 BUSINESS DAYS PRIOR TO CONSTRUCTION. CALL NUMBER (206)-386-1800. 14.2.AN EXISTING CATHODIC PROTECTION SYSTEM IS PRESENT AT THE CROSSING LOCATION OF THE SPU TRANSMISSION PIPELINE. PROTECT EXISTING CATHODIC PROTECTION SYSTEM. 14.3.CLEARANCE BETWEEN SPU WATER TRANSMISSION PIPELINE AND PROPOSED STORM DRAIN SHALL BE 12" MIN. CONTRACTOR TO ALERT ENGINEER AND SPU IF MINIMUM CLEARANCE CANNOT BE MET PRIOR TO CONSTRUCTION. 1 1 Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 CIVIL IMPROVEMENT PLAN 0 1 inch = 10 feet 5'10'20' MA T C H L I N E : R E F E R T O S H E E T C3 . 0 2 R-433408 REFER TO SHEET C3.00 FOR CONTINUATION MA T C H L I N E : R E F E R T O S H E E T C3 . 0 3 1 2025-09-15 WATER UTILITY JValdez 09/17/2025 DEVELOPMENT ENGINEERING msippo 10/02/2025 • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 37.6 37.8 38.0 38.2 38. 4 38.2 3 8 . 4 3 8 . 6 38 . 6 38 . 8 39. 0 38.8 38.6 38.8 38.4 38.6 38.8 38.8 38.6 2 C3.14 1 C3.51 PARCEL #5696000055 38 22+00 23+00 23+17.14S 3RD ST BU R N E T T A V E S EXIST WATER FEATURE, RE-PURPOSED AS A LANDSCAPE PLANTER, REFER TO LS PLANS PIAZZA PARK PIAZZA PARK GRADING ENLARGEMENT EAST ADJUST RIM TO FG PROP RIM 38.6± PROP LIGHTING ROUTING (1)-3 4" PVC CONDUIT REFER TO ELEC PLANS PROP LIGHTING ROUTING (2)-3 4" PVC CONDUITS (2)-1" PVC CONDUITS REFER TO ELEC PLANS INTERCEPT EXIST 3 4" CONDUIT REFER TO ELEC PLANS INTERCEPT EXIST 3 4" CONDUIT REFER TO ELEC PLANS INTERCEPT EXIST 3 4" CONDUIT REFER TO ELEC PLANS RIGHT-OF-WAY LINE, TYP REFER TO LS PLANS FOR SOFTSCAPE GRADING, TYP PROP LIGHT POLE, REFER TO LS AND ELEC PLAN, TYP 4" IE OUT 35.0(SE) AD 14 RIM 37.4 4" IE OUT 35.15 (W) 4" FRENCH DRAIN (FD), TYP SLOPE @ 0.5% MIN 66" SPU WATER MAIN 52" SPU WATER MAIN PROP LIGHTING ROUTING (2)-3 4" PVC CONDUITS (2)-1" PVC CONDUITS REFER TO ELEC PLANS 1 C3.10 SOUTH ENTRY ENLARGEMENT LIMITS OF WORK, TYP PROP FLUSH CONCRETE CURB, TYP 1 C4.50 SPU PARCEL #000720-0188 CONTRACTOR SHALL COORDINATE WITH SPU PRIOR TO AND DURING ANY CONSTRUCTION WITHIN THE SPU PARCEL NOTES: 1.REFER TO C1.00 TO C1.02 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS. REFER TO C3.00 FOR CIVIL IMPROVEMENT'S LEGEND AND NOTES. 2.CONTRACTOR SHALL CONFIRM POC'S PRIOR TO CONSTRUCTION WHEN CONNECTING TO EXISTING SYSTEMS AND NOTIFY ENGINEER OF ANY DISCREPANCIES. PRIOR TO CONSTRUCTION, FIELD VERIFY DOWNSTREAM INVERTS FOR ALL EXISTING SS AND SD PIPES, AREA DRAINS AND CATCH BASINS WITH PROPOSED UPSTREAM CONNECTIONS. CONFIRM EXISTING OUTLET INVERTS PROVIDE POSITIVE DRAINAGE FOR ALL UPSTREAM PIPES. PIPES SHALL BE VERIFIED WITH DYE TEST, CCTV, OR OTHER METHOD COORDINATED AND APPROVED BY CITY OF RENTON. COORDINATE TESTING WITH CITY. CONFIRM DRINKING FOUNTAIN IS CONNECT TO EXIST DOMESTIC WATER SUPPLY PRIOR TO INSTALLATION. 3.PROJECT ASSUMES THAT ALL CITY EXISTING UTILITY INFRASTRUCTURE IS ADEQUATELY SIZED TO SUPPORT THE PROJECT. 4.PRIOR TO DEMOLITION, CONTRACTOR SHALL FIELD VERIFY AND LOCATE ALL EXISTING UTILITIES TO REMAIN WITHIN AND ADJACENT TO LIMIT OF WORK. 5.ALL EXISTING PAVEMENT STRIPING DISTURBED DURING CONSTRUCTION SHALL BE REPLACED IN KIND. PRODUCTS SHALL BE PER CITY OF RENTON PUBLIC WORKS DEPARTMENT STANDARD PLANS AND SPECIFICATIONS, AND WSDOT STANDARD PLANS AND SPECIFICATIONS. CONTRACTOR SHALL SUBMIT A PAVEMENT RESTORATION PLAN INCLUDING, CUTTING AND JOINTING, FOR ALL PAVEMENT BEING DISTURBED. 6.FULL DEPTH PAVEMENT REPLACEMENT, AND TRENCH RESTORATION AT UTILITY CUTS, SHALL BE PER CITY OF RENTON STD DETAILS. PAVEMENT SECTION SHALL BE PER CITY OF RENTON STD DETAILS, OR MATCH EXISTING WHICHEVER IS GREATER. MATCH EXISTING PAVEMENT MATERIAL PER ASSOCIATED STANDARD DETAILS. TRENCH AND BACKFILL SHALL BE PER CITY OF RENTON RENTON STD. PLAN 220.20. PEDESTRIAN CONCRETE PAVEMENT SHALL BE PER CITY OF RENTON STD. PLAN 102. VEHICULAR CONCRETE PAVING SHALL BE PER CITY OF RENTON RENTON STD. PLAN 110, 110.1 AND 111 AND PROJECT DETAILS. 7.PEDESTRIAN CONCRETE, MINIMUM SECTION: 4" CONCRETE 6" CSBC REFER TO LANDSCAPE FOR CONCRETE SCORING, COLOR, AND FINISHES. 8.THE RENTON MARKET AND PIAZZA PROJECT IS REQUIRED TO MEET STORMWATER REQUIREMENTS PER THE 2022 CITY OF RENTON SURFACE WATER DESIGN MANUAL (RSWDM). 8.1.FLOW CONTROL: THE PROJECT PROPOSES MORE THAN 5,000 SQUARE FEET OF NEW PLUS REPLACED IMPERVIOUS SURFACE AND IS LOCATED IN THE PEAK FLOW RATE CONTROL STANDARD AREA. TARGET SURFACES DO NOT GENERATE MORE THAN A 0.15-CFS INCREASE IN THE EXISTING SITE CONDITIONS 100-YR PEAK FLOW, THEREFORE FLOW CONTROL IS NOT REQUIRED. 8.2.WATER QUALITY: THE PROJECT PROPOSES LESS THAN 5,000 SQUARE FEET OF NEW PLUS REPLACED IMPERVIOUS SURFACE (PGIS), AND LESS THAN ¾ ACRES OF POLLUTANT GENERATION PERVIOUS SURFACE (PGPS), THEREFORE WATER QUALITY IS NOT REQUIRED. 8.3.ON-SITE BMPS: THE PROJECT PROPOSES MORE THAN 2,000-SF OF NEW PLUS IMPERVIOUS SURFACE, THEREFORE ON-SITE STORMWATER MANAGEMENT (OSM) IS REQUIRED. ALL AVAILABLE OSM BMP'S WERE EVALUATED AND ARE NOT FEASIBLE FOR THE SITE. 8.4.THE PROJECT IS LOCATED IN AN AQUIFER PROTECTION AREA, THEREFORE STORMWATER MITIGATION FACILITIES SHALL NOT INFILTRATE AND SHALL BE COLLECTED VIA STORMWATER CONVEYANCE AND DISCHARGE TO THE CITY MAIN. 9.GREASE INTERCEPTOR SIZE AND VAULT PER MECHANICAL. 10.ELECTRICAL SERVICE FOR THE SITE IS PER ELECTRICAL. 11.STORM, SEWER, AND WATER INFRASTRUCTURE SHALL BE PER CITY OF RENTON STANDARDS AND WSDOT STANDARD SPECIFICATIONS, UNLESS OTHERWISE NOTED. 12.STORM DRAINAGE PIPE MATERIAL SHALL BE PER RSWDM TABLE 4.2.1.A2, UNLESS OTHERWISE NOTED. 13.ALL REGULATORY SIGNAGE AND PAVEMENT STRIPING SHALL CONFORM TO CITY OF RENTON AND MUTCD SPECIFICATIONS. 14.LOCATION AND DEPTH OF EXISTING SPU WATER MAINS (TRANSMISSION PIPE LINES) IS APPROXIMATE. 14.1.SPU SHALL BE NOTIFIED AND ONSITE WHILE CONTRACTOR PERFORMS ANY CONSTRUCTION WITHIN THE SPU PARCEL. SPU SHALL BE NOTIFIED AT LEAST 3 BUSINESS DAYS PRIOR TO CONSTRUCTION. CALL NUMBER (206)-386-1800. 14.2.AN EXISTING CATHODIC PROTECTION SYSTEM IS PRESENT AT THE CROSSING LOCATION OF THE SPU TRANSMISSION PIPELINE. PROTECT EXISTING CATHODIC PROTECTION SYSTEM. 14.3.CLEARANCE BETWEEN SPU WATER TRANSMISSION PIPELINE AND PROPOSED STORM DRAIN SHALL BE 12" MIN. CONTRACTOR TO ALERT ENGINEER AND SPU IF MINIMUM CLEARANCE CANNOT BE MET PRIOR TO CONSTRUCTION. 1 1 Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 CIVIL IMPROVEMENT PLAN 0 1 inch = 10 feet 5'10'20' RE F E R T O S H E E T C3 . 0 1 F O R C O N T I N U A T I O N R-433409 REFER TO SHEET C3.00 FOR CONTINUATION 1 2025-09-15 WATER UTILITY JValdez 09/17/2025 DEVELOPMENT ENGINEERING msippo 10/02/2025 NOTES: 1.REFER TO C1.00 TO C1.02 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS. REFER TO C3.00 FOR CIVIL IMPROVEMENT'S LEGEND AND NOTES. 2.CONTRACTOR SHALL CONFIRM POC'S PRIOR TO CONSTRUCTION WHEN CONNECTING TO EXISTING SYSTEMS AND NOTIFY ENGINEER OF ANY DISCREPANCIES. PRIOR TO CONSTRUCTION, FIELD VERIFY DOWNSTREAM INVERTS FOR ALL EXISTING SS AND SD PIPES, AREA DRAINS AND CATCH BASINS WITH PROPOSED UPSTREAM CONNECTIONS. CONFIRM EXISTING OUTLET INVERTS PROVIDE POSITIVE DRAINAGE FOR ALL UPSTREAM PIPES. PIPES SHALL BE VERIFIED WITH DYE TEST, CCTV, OR OTHER METHOD COORDINATED AND APPROVED BY CITY OF RENTON. COORDINATE TESTING WITH CITY. CONFIRM DRINKING FOUNTAIN IS CONNECT TO EXIST DOMESTIC WATER SUPPLY PRIOR TO INSTALLATION. 3.PROJECT ASSUMES THAT ALL CITY EXISTING UTILITY INFRASTRUCTURE IS ADEQUATELY SIZED TO SUPPORT THE PROJECT. 4.PRIOR TO DEMOLITION, CONTRACTOR SHALL FIELD VERIFY AND LOCATE ALL EXISTING UTILITIES TO REMAIN WITHIN AND ADJACENT TO LIMIT OF WORK. 5.ALL EXISTING PAVEMENT STRIPING DISTURBED DURING CONSTRUCTION SHALL BE REPLACED IN KIND. PRODUCTS SHALL BE PER CITY OF RENTON PUBLIC WORKS DEPARTMENT STANDARD PLANS AND SPECIFICATIONS, AND WSDOT STANDARD PLANS AND SPECIFICATIONS. CONTRACTOR SHALL SUBMIT A PAVEMENT RESTORATION PLAN INCLUDING, CUTTING AND JOINTING, FOR ALL PAVEMENT BEING DISTURBED. 6.FULL DEPTH PAVEMENT REPLACEMENT, AND TRENCH RESTORATION AT UTILITY CUTS, SHALL BE PER CITY OF RENTON STD DETAILS. PAVEMENT SECTION SHALL BE PER CITY OF RENTON STD DETAILS, OR MATCH EXISTING WHICHEVER IS GREATER. MATCH EXISTING PAVEMENT MATERIAL PER ASSOCIATED STANDARD DETAILS. TRENCH AND BACKFILL SHALL BE PER CITY OF RENTON RENTON STD. PLAN 220.20. PEDESTRIAN CONCRETE PAVEMENT SHALL BE PER CITY OF RENTON STD. PLAN 102. VEHICULAR CONCRETE PAVING SHALL BE PER CITY OF RENTON RENTON STD. PLAN 110, 110.1 AND 111 AND PROJECT DETAILS. 7.PEDESTRIAN CONCRETE, MINIMUM SECTION: 4" CONCRETE 6" CSBC REFER TO LANDSCAPE FOR CONCRETE SCORING, COLOR, AND FINISHES. 8.THE RENTON MARKET AND PIAZZA PROJECT IS REQUIRED TO MEET STORMWATER REQUIREMENTS PER THE 2022 CITY OF RENTON SURFACE WATER DESIGN MANUAL (RSWDM). 8.1.FLOW CONTROL: THE PROJECT PROPOSES MORE THAN 5,000 SQUARE FEET OF NEW PLUS REPLACED IMPERVIOUS SURFACE AND IS LOCATED IN THE PEAK FLOW RATE CONTROL STANDARD AREA. TARGET SURFACES DO NOT GENERATE MORE THAN A 0.15-CFS INCREASE IN THE EXISTING SITE CONDITIONS 100-YR PEAK FLOW, THEREFORE FLOW CONTROL IS NOT REQUIRED. 8.2.WATER QUALITY: THE PROJECT PROPOSES LESS THAN 5,000 SQUARE FEET OF NEW PLUS REPLACED IMPERVIOUS SURFACE (PGIS), AND LESS THAN ¾ ACRES OF POLLUTANT GENERATION PERVIOUS SURFACE (PGPS), THEREFORE WATER QUALITY IS NOT REQUIRED. 8.3.ON-SITE BMPS: THE PROJECT PROPOSES MORE THAN 2,000-SF OF NEW PLUS IMPERVIOUS SURFACE, THEREFORE ON-SITE STORMWATER MANAGEMENT (OSM) IS REQUIRED. ALL AVAILABLE OSM BMP'S WERE EVALUATED AND ARE NOT FEASIBLE FOR THE SITE. 8.4.THE PROJECT IS LOCATED IN AN AQUIFER PROTECTION AREA, THEREFORE STORMWATER MITIGATION FACILITIES SHALL NOT INFILTRATE AND SHALL BE COLLECTED VIA STORMWATER CONVEYANCE AND DISCHARGE TO THE CITY MAIN. 9.GREASE INTERCEPTOR SIZE AND VAULT PER MECHANICAL. 10.ELECTRICAL SERVICE FOR THE SITE IS PER ELECTRICAL. 11.STORM, SEWER, AND WATER INFRASTRUCTURE SHALL BE PER CITY OF RENTON STANDARDS AND WSDOT STANDARD SPECIFICATIONS, UNLESS OTHERWISE NOTED. 12.STORM DRAINAGE PIPE MATERIAL SHALL BE PER RSWDM TABLE 4.2.1.A2, UNLESS OTHERWISE NOTED. 13.ALL REGULATORY SIGNAGE AND PAVEMENT STRIPING SHALL CONFORM TO CITY OF RENTON AND MUTCD SPECIFICATIONS. 14.LOCATION AND DEPTH OF EXISTING SPU WATER MAINS (TRANSMISSION PIPE LINES) IS APPROXIMATE. 14.1.SPU SHALL BE NOTIFIED AND ONSITE WHILE CONTRACTOR PERFORMS ANY CONSTRUCTION WITHIN THE SPU PARCEL. SPU SHALL BE NOTIFIED AT LEAST 3 BUSINESS DAYS PRIOR TO CONSTRUCTION. CALL NUMBER (206)-386-1800. 14.2.AN EXISTING CATHODIC PROTECTION SYSTEM IS PRESENT AT THE CROSSING LOCATION OF THE SPU TRANSMISSION PIPELINE. PROTECT EXISTING CATHODIC PROTECTION SYSTEM. 14.3.CLEARANCE BETWEEN SPU WATER TRANSMISSION PIPELINE AND PROPOSED STORM DRAIN SHALL BE 12" MIN. CONTRACTOR TO ALERT ENGINEER AND SPU IF MINIMUM CLEARANCE CANNOT BE MET PRIOR TO CONSTRUCTION. 1 1 PROP LIGHT POLE AND FOOTING, TYP REFER TO ELEC AND STRUCT PLANS MATCH EXIST GRADES AT EXIST PAVEMENT AND RESTORE PAVEMENT TO NEAREST JOINT LINE, TYP PROP LIGHTING POC COORDINATE WITH WORLD CUP SQUARE PROJECT FOR ROUTING TO SERVICE CABINET (1) 2" PVC CONDUITS REFER TO ELEC PLANS 4.0' S 3RD ST 4. 0 ' PROP LIGHTING ROUTING (1) 2" PVC CONDUIT REFER TO ELEC PLANS LO G A N A V E S WORLD CUP LEGACY SQUARE PROJECT (BY OTHERS) PERMIT #CAG-25-044 RIGHT-OF-WAY LINE, TYP LIMITS OF WORK, TYP PROP LIGHT POLE POC, TYP ELEC JUNCTION BOX, TYPE 1 PER COR STD PLAN 119 AND 120, AND WSDOT STD PLAN J-40.10-04(1) 2" PVC CONDUIT, REFER TO ELEC PLANS 1 Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 CIVIL IMPROVEMENT PLAN 0 1 inch = 10 feet 5'10'20' R-4334010 MA T C H L I N E : R E F E R T O S H E E T C3 . 0 1 1 2025-09-15 WATER UTILITY JValdez 09/17/2025 DEVELOPMENT ENGINEERING msippo 10/02/2025 2 C3.51 VA R I E S 0. 9 % - 1 . 8 % VA R I E S 0. 9 % - 1 . 8 % 3 C3.51 3 7 . 7 4 G B 1. 8 0 % 37. 7 0 FFE: 37.83 3 7 . 7 3 ( E X ) 37.43 (E X ) 37. 5 1 ( E X ) 37. 7 5 ( E X ) 37. 6 6 ( E X ) 37. 6 8 ( E X ) 37. 8 0 ( E X ) 3 7 . 8 7 37. 8 4 1. 8 1 % 37.8 0 ( E X ) 0. 9 7 % 0.31% 37. 9 3 ( E X ) 37. 7 2 37. 6 1 G B 0.60% 1. 8 0 % 37.8 0 G B 37. 9 1 G B 60 LF 6" SD 24 LF 8" SD @ 0.4% ± RENTON MARKET 0.75 % REFER TO ARCH FOR BUILDING VESTIBULE AND ENCLOSURE PEDESTRIAN CONCRETE PAVING, TYP GRADE IN PLANAR FASHION BETWEEN SPOTS PROVIDED, TYP MATCH EXIST GRADE AT EXIST PAVEMENT, TYP INLINE CATCH BASIN. CONNECT TO EXIST SD REFER TO NOTE 3 RIM 37.4± 8" IE OUT 35.13 63 LF 4" TRENCH DRAIN (TD) SLOPE BOTTOM OF TD @ 0.5% MIN TOWARDS INLINE CATCH BASIN. REFER TO NOTE 3. TD RIM 37.7± IE 36.89 GRADE BREAK, TYP OVERHANG EXTENTS PER ARCH 6" ROOF DRAIN, SLOPE @ 0.5% MIN AREA DRAIN (AD) WITH SOLID LID REROUTE EXIST 8" SD RIM 37.6± 8" IE 34.49 ± IN, SE (EX) 8" IE 34.49 ± OUT, W AREA DRAIN WITH SOLID LID CONNECT TO EXIST 8" SD RIM: 37.6± 6" IE 34.68± IN (N) 6" IE 34.68± IN (E) 8" IE 34.35± IN (S) 8" IE 34.35± OUT (SW,EX) 9 LF 8" SD @ 0.4% ± DOWNSPOUT CONNECTION ROOF DRAIN POC REFER TO ARCH FOR CONTINUATION, TYP CLEANOUT (CO), TYP ADJUST ELEC AS NEEDED, REPLACE IN KIND, TYP 2 LF 8" SD @ 0.5% MIN 37. 7 1 G B 37.4 2 G B NOTES: 1.REFER TO C1.00 TO C1.02 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS. 2.REFER TO C3.00 FOR CIVIL IMPROVEMENT'S NOTES. 3.TRENCH DRAIN AND INLINE CB SHALL BE ACO KLASSIKDRAIN WITH ASSOCIATED LONGITUDINAL IRON GRATE, OR APPROVED EQUIVALENT, AND SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURER’S SPECIFICATIONS. Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 0 1 inch = 5 feet 2.5'5'10' 1 - SOUTH ENTRY ENLARGEMENT ENLARGEMENT PLAN R-433411 2025-07-15 DEVELOPMENT ENGINEERING msippo 08/13/2025 2 C4.51 BU R N E T T A V E S BC 37. 6 3 ( E X ) TC 38 . 1 6 ( E X ) 37.70 ( E X ) 37.71 ( E X ) BC 37. 6 9 ( E X ) TC 38 . 1 8 ( E X ) 38.36 ( E X ) 38.42 ( E X ) 7.39% 6.74% 0. 3 1 % ± 0. 0 6 % ± 7. 8 4 % 7. 6 7 % 12+00 0. 4 ' 7. 5 ' 3.0' 6. 0 ' 6. 0 ' 22.5' DRIVEWAY PER CITY OF RENTON STANDARD PLAN 104.2 PROTECT EXIST UTILITIES, TYP INSTALL RIGHT TURN ONLY SIGN, R3-5R EXIST BOLLARD, TYP MATCH EXIST GRADES, TYP REMOVABLE BOLLARD MOUNTING BASE PLATE FOR BOLLARD STORAGE, REFER TO LS PLAN. LOCATE EXIST UTILITIES PRIOR TO CONSTRUCTION, NOTIFY ENGINEER OF ANY CONFLICTS RIGHT-OF-WAY, TYP REMOVABLE BOLLARDS, REFER TO LS PLAN LOCATE EXIST UTILITIES PRIOR TO CONSTRUCTION, NOTIFY ENGINEER OF ANY CONFLICTS EQ EQ 2. 0 ' 9.1' ± 22 . 5 ' CONCRETE PAD, REFER TO LS PLANS FIXED BOLLARD, TYP 4 C4.50 4. 0 ' 10 . 0 ' NOTES: 1.REFER TO C1.00 TO C1.02 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS. 2.REFER TO C3.00 FOR CIVIL IMPROVEMENT'S NOTES. 3.TRENCH DRAIN AND INLINE CB SHALL BE ACO KLASSIKDRAIN WITH ASSOCIATED LONGITUDINAL IRON GRATE, OR APPROVED EQUIVALENT, AND SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURER’S SPECIFICATIONS. Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 0 1 inch = 5 feet 2.5'5'10' 1 - DRIVEWAY ENLARGEMENT ENLARGEMENT PLAN R-433412 2025-07-15 DEVELOPMENT ENGINEERING msippo 08/13/2025 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 3 C3.20 2 C3.50 LO G A N A V E S 10+00 11+00 4.0'6" SS @ 1.0% MIN, TYP EXIST SS CO AND SIDE SEWER, 6" IE ~ 31.76 ± REFER TO ADD ALT #2 ON SHEET C3.00 EXIST SIDE SEWER REFER TO ADD ALT #2 ON SHEET C3.00 GREASE INTERCEPTOR (GI) VAULT REFER TO PLUMB PLAN CIVIL POC 6" IE OUT: 33.5 REPLACE LANDSCAPE, REFER TO LS PLAN PEDESTRIAN CONCRETE PAVING, TYP EXIST BUILDING, TYP SS LINE 10 SSCO, TYP EX SSMH NOTES: 1.REFER TO C1.00 TO C1.02 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS. 2.REFER TO C3.00 FOR CIVIL IMPROVEMENT'S NOTES. 3.TRENCH DRAIN AND INLINE CB SHALL BE ACO KLASSIKDRAIN WITH ASSOCIATED LONGITUDINAL IRON GRATE, OR APPROVED EQUIVALENT, AND SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURER’S SPECIFICATIONS. Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 0 1 inch = 5 feet 2.5'5'10' 1 - SIDE SEWER ENLARGMENT ENLARGEMENT PLAN S-433413 2025-07-15 DEVELOPMENT ENGINEERING msippo 08/13/2025 WASTEWATER UTILITY jstowell 08/13/2025 • • • • • • • • • • • • • • • • 37.8 37.6 37 . 4 37 . 2 37 . 0 36 . 8 36 . 6 36. 8 37. 0 37. 2 3 7 . 4 37.2 37.4 37.6 37.8 37.6 37.4 37.2 37.0 36.8 37.41 GB MATCH EXIST GRADES AT EXIST PAVEMENT, TYP 37 . 5 ± G B ( E X ) 37.6± G B ( E X ) 37.5± ( E X ) 37.0± ( E X ) 3 . 7 2 % 0. 7 5 % 0.7 5 % 1.50% 0.6 0 % 3 7 . 0 ± ( E X ) 36.6 ± ( E X ) 36.6 ± ( E X ) 0. 1 5 % 1.19% 1.50% 0.6 8 % 0. 5 0 % 1.0 % ± ( E X ) EXI S T VA R I E S ±0. 0 % E X I S T V A R I E S ± 0 . 7 % 37.6± ( E X ) EX I S T V A R I E S ±0 . 0 % EXIST VARIES ±2.7% 10 . 0 0 ' 8.50' 37.6± ( E X ) 0. 4 8 % MATCH EXIST GRADES AT EXIST PAVEMENT, TYP REFER TO LS PLANS FOR SOFTSCAPE GRADING, TYP FLUSH CURB, TYP REFER TO C3.01 AND C3.02 36.6 ± ( E X ) 37.5± (EX) 37. 4 ± ( E X ) 37 . 5 ± G B ( E X ) 0.0%± (EX) 0.8%± (EX)0.7%± (EX) 0. 3 % ± ( E X ) 0. 2 4 % 0.80% 0.51% 36 . 8 3 7 . 0 36. 6 3 6 . 8 3 7 . 2 3 7 . 4 37.32 G B 37.4 37 . 4 37.2 37.4 VA R I E S 1. 4 % - 3 . 3 % VARIES 0.5%-2.0% 36 . 7 8 37.31 37.35 G B 37.14 36.6 6 G B 36.6 4 G B MATCH EXIST GRADES AT EXIST PAVEMENT AND RESTORE PAVEMENT TO NEAREST JOINT LINE, TYP. 37.55± 37 . 4 ± 37.3± 36. 7 5 ± 36 . 6 ± ( E X ) NOTES: 1.REFER TO C1.00 TO C1.02 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS. 2.REFER TO C3.00 FOR CIVIL IMPROVEMENT'S NOTES. Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 ENLARGEMENT PLAN 0 1 inch = 10 feet 5'10'20' 1 C3.01 PIAZZA PARK GRADING ENLARGEMENT WEST SCALE: 1" = 10' R-433414 1 1 2025-09-15 DEVELOPMENT ENGINEERING msippo 10/02/2025 37.6 37.8 38.0 38.2 38. 4 38.2 3 8 . 4 3 8 . 6 38 . 6 38 . 8 39. 0 38.8 38.4 38.6 38.8 38.8 38.6 MATCH EXIST GRADES AT EXIST PAVEMENT, TYP 37.7 ± ( E X ) 38.8± ( E X ) 38. 8 ± ( E X ) 37. 9 9 G B 38.5± G B ( E X ) 38.6± ( E X ) 38.22 G B 38. 6 2 38.9± ( E X ) 38.9± ( E X ) 38. 6 2 G B 38.07 G B 38.48 G B 38.26 G B 38. 5 8 G B 0. 7 6 % 0.89 % 1.33% 1. 7 1 % 4.72% 3.8 1 % 2.13% 0. 0 2 % 1.27% 1.55% 0.2 9 % 2. 5 9 % 1.48% 1.78 % 2.07% 0. 7 % ± ( E X ) 1. 0 % ± ( E X ) 38.8± ( E X ) 37. 4 ± ( E X ) 37.4 ± ( E X ) 3 7 . 4 ± G B ( E X ) 2. 0 5 % EXIST VARIES ±2.3% EX I S T VA R I E S ±1 . 1 % E X I S T V A R I E S ± 2 . 1 % 0. 2 % ± ( E X ) 38.5± (EX ) 3 . 3 3 % 37. 3 ± ( E X ) 37. 8 ± ( E X ) 37.8± (EX) 37.5± (EX) 37.5± (EX ) 2. 3 6 % REFER TO LS PLANS FOR SOFTSCAPE GRADING, TYP FLUSH CURB, TYP REFER TO C3.01 AND C3.02 37 . 8 ± ( E X ) 37.8 ± ( E X ) 37.8 ± ( E X ) 37.9± G B ( E X ) 37.95 38.00 G B 0. 7 5 % 1. 5 5 % 38. 0 0 EXIST VARIES ±1.8% 38.8 38.0 37.6 37.8 38 . 2 38 . 4 38 . 6 38 . 8 37.6 8. 8 0 ' 38. 6 ± 37. 4 ± NOTES: 1.REFER TO C1.00 TO C1.02 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS. 2.REFER TO C3.00 FOR CIVIL IMPROVEMENT'S NOTES. 3.TRENCH DRAIN AND INLINE CB SHALL BE ACO KLASSIKDRAIN WITH ASSOCIATED LONGITUDINAL IRON GRATE, OR APPROVED EQUIVALENT, AND SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURER’S SPECIFICATIONS. Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 ENLARGEMENT PLAN 1 C3.02 PIAZZA PARK GRADING ENLARGEMENT EAST SCALE: 1" = 5' 0 1 inch = 5 feet 2.5'5'10' R-433415 2025-07-15 DEVELOPMENT ENGINEERING msippo 08/13/2025 20 30 40 50 20 30 40 50 0+00 0+50 1+00 1+50 20 30 40 50 20 30 40 50 12" IE OUT=33.60 (S) 8" IE IN=33.60± (N) EXIST SDCB RIM=35.58 13 LF 8" DI SD @ 0.65% 8" IE OUT=33.68 (S) 8" IE IN=33.68 (E) SDCB 100, TYPE 1 RIM=35.59 8" IE OUT=34.29 (W) 8" IE IN=34.29 (S) AD 10, 8" RIM=37.47 39 LF 8" HDPE SD @ 0.65% 8" IE OUT=34.55 (N) 6" IE IN=34.55 (NE) AD 11, 8" RIM=37.30 27 LF 6" HDPE SD @ 1.00% 6" IE OUT=34.82 (SW) AD 12, 8" RIM=37.40 0+00 8" IE OUT=34.27 (N) AD 20 RIM=36.75 94 LF 8" DI SD @ 0.65% 10 20 30 40 50 60 10 20 30 40 50 60 0+00 0+50 1+00 1+50 6" IE OUT=31.91 (S) 6" IE IN=31.91 (E) SSCO RIM=36.23 1 C3.01 SD PROFILE 10 SCALE: H: 1"=10' V: 1"=10' 2 C3.01 SD PROFILE 20 SCALE: H: 1"=10' V: 1"=10' 3 C3.00 SS PROFILE 10 SCALE: H: 1"=10' V: 1"=10' EXIST POWER ASSUMED DEPTH EXIST POWER AND COMM ASSUMED DEPTH BUILDING POC REFER TO PLUMB PLAN GI VAULT, REFER TO PLUMB PLAN EX 4" W EX 1.5" W EX 1" IRR PROP GRADE, TYP EXIST GRADE, TYP PROP GRADE, TYP EXIST GRADE, TYP MATCH EXIST GRADE, TYP EXIST WATER ASSUMED DEPTH, ADJUSTMENT OF WATER AND SS MAY BE NEEDED, COORDINATE WITH ENGINEER, REFER TO NOTE 4 EXIST SS 8" IE=31.4± EXIST SD 6" IE=32.2± EXIST MARKET BLDG 6" SS PVC @ 1.0% MIN REFER TO PLAN FOR LANDSCAPE FD 31 LF 8" DI SD @ 1.00% 1 LF 6" SS @ 53.33% GI POC WITH ECCENTRIC REDUCER 4" IE=33.50 6" IE=33.50 6" IE=32.46 SPU PARCEL LINE SPU PARCEL LINE ROW PROPERTY LINE PROPERTY LINE 6" IE OUT=31.76± (W), EX 6" IE IN=31.76± (N) EXIST SSCO, RIM=36.19 PROPERTY LINE CL 85 LF 6" SS PVC @ 1.25% 11 LF 6" SS PVC @ 1.25% 52" SPU WATER MAIN @ ~4' COVER52" SPU WATER MAIN @ ~4' COVER 66" SPU WATER MAIN @ ~4.5' COVER 66" SPU WATER MAIN @ ~4.5' COVER 52" SPU WATER MAIN @ ~4' COVER NOTES: 1.REFER TO C1.00 TO C1.02 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS. 2.REFER TO C3.00 FOR CIVIL IMPROVEMENT'S NOTES. 3.INSTALL ETHAFOAM AT CROSSING WITH LESS THAN 12" OF CLEARANCE. REFER TO DETAIL 4/C3.51. 4.CONTRACTOR TO LOCATE EXISTING UTILITIES PRIOR TO INSTALLING PIPES. NOTIFY ENGINEER OF DISCREPANCIES AND COORDINATE CONFLICTS WITH DESIGN TEAM. 5.LOCATION AND DEPTH OF EXISTING SPU WATER MAINS (TRANSMISSION PIPE LINES) IS APPROXIMATE. 5.1.SPU SHALL BE NOTIFIED AND ONSITE WHILE CONTRACTOR PERFORMS ANY CONSTRUCTION WITHIN THE SPU PARCEL. SPU SHALL BE NOTIFIED AT LEAST 3 BUSINESS DAYS PRIOR TO CONSTRUCTION. CALL NUMBER (206)-386-1800 5.2.AN EXISTING CATHODIC PROTECTION SYSTEM IS PRESENT AT THE CROSSING LOCATION OF THE SPU TRANSMISSION PIPELINE. PROTECT EXISTING CATHODIC PROTECTION SYSTEM. 5.3.CLEARANCE BETWEEN SPU WATER TRANSMISSION PIPELINE AND PROPOSED STORM DRAIN SHALL BE 12" MIN. CONTRACTOR TO ALERT ENGINEER AND SPU IF MINIMUM CLEARANCE CANNOT BE MET PRIOR TO CONSTRUCTION. Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 STORM & SEWER PROFILES R-433416 1 1 1 2025-09-15 DEVELOPMENT ENGINEERING msippo 10/02/2025 Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 1TYPICAL TRENCH AND BACKFILL NTS 2CLEANOUT FOR SANITARY SEWER SERVICE NTS 3PIPE BEDDING FOR SANITARY SEWERS NTS CIVIL IMPROVEMENT DETAILS R-433417 2025-07-15 DEVELOPMENT ENGINEERING msippo 08/13/2025 Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 CIVIL IMPROVEMENT DETAILS 6" VARIES (6" MIN) 6" 12" MIN PLANTING SOIL, REFER TO LS PLANS GRAVEL BACKFILL FOR DRAINS SLOTTED PIPE @ 0.5% MIN SIZE PER PLAN TYPICAL FRENCH DRAIN IN LANDSCAPE AREA FINISH GRADE PER PLAN 1FRENCH DRAIN NTS 4" BELOW GRADE (TYP) PLUG OR PIPE EXTENSION HARDSCAPE CLEANOUT SOFTSCAPE CLEANOUT HARDSCAPE AREA 45° BEND CLEANOUT NOTES: 1.CLEANOUT SIZE SHALL BE 4-INCH FOR ALL PIPE SIZES IN HARDSCAPE AREAS. PROVIDE PIPE REDUCER OR 4-INCH BRANCH ON WYE AS APPLICABLE. 2.SHALLOW CLEANOUTS AND CLEANOUTS IN SOFTSCAPE AREAS SHALL BE SIZED TO MATCH PIPE SIZE FOR PIPES EQUAL TO OR LESS THAN 6-INCHES. PIPES LARGER THAN 6-INCHES SHALL USE 6-INCH CLEANOUT WITH PIPE REDUCER OR 6-INCH BRANCH ON WYE AS APPLICABLE PIPE AND SIZE PER PLAN WYE, REFER TO CLEANOUT NOTE 1 SOFTSCAPE CLEANOUT, REFER TO CLEANOUT NOTE 2 PIPE AND SIZE PER CLEANOUT NOTE 2 4" PIPE HARDSCAPE PER PLAN PLUG OR PIPE EXTENSION PIPE AND SIZE PER PLAN WYE, REFER TO CLEANOUT NOTE 2 45° BEND 3STORM DRAIN CLEANOUT NTS R-433418 TRENCH DRAIN PER PLAN PAVEMENT PER LANDSCAPING, TYP #4 NOSING BAR, TYP 1 1 6" 6" 6" EXPANSION JOINT, TYP EQ EQ #4 BAR, 12" O.C., TYP EQEQ 2TRENCH DRAIN NTS UPPER UTILITY LOWER UTILITY 0.5" MIN LESS THAN 12" CLEARANCE PACK GAP BETWEEN UTILITIES AT CROSSING W/ 6" THICK POLYETHYLENE PLASTIC FOAM PAD 4ETHAFOAM INSTALLATION DETAIL NTS 2025-07-15 DEVELOPMENT ENGINEERING msippo 08/13/2025 4' WHITE PAINTED STRIPE CURB FACE/BACK OF STALL 18 . 0 ' 9.0' Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 LANDSCAPE, REFER TO LS PLANS, TYP NOTES: 1.CONCRETE CURB SHALL BE CLASS 3000 CEMENT CONCRETE. 2.CURBS SHALL HAVE THRU-JOINTS AT 10 FT O.C. 6" R=1/2"R=1/2" 1FLUSH CURB DETAIL NTS PAVING DETAIL 2-4" PERMEABLE SURFACING BASE COURSE REFER TO LS PLANS FOR DETAILING OF PAVEMENT RELATIONSHIP TO TRUNK AND FLARE. 1" OF LOOSE 3/8" RUBBER GRANULE WITH NO BINDER IN AN 18" DIAMETER CIRCLE AROUND TREE TRUNK. 2" PERMEABLE SURFACING WEARING COURSE GEO-GRID GEOTEXTILE FABRIC EXISTING TREE 2" PERMEABLE SURFACING WEARING COURSE HARDSCAPE PER PLAN, TYP 2PERMEABLE PAVING TYPICAL SECTION NTS PRIME EDGES PER MANUFACTURES RECOMMENDATIONS, TYP HARDSCAPE PER PLAN, TYP PRIME EDGES PER MANUFACTURES RECOMMENDATIONS, TYP 2-4" PERMEABLE SURFACING BASE COURSE REFER TO LS PLANS FOR SOIL CELLS, SUBBASE, AND LANDSCAPE SECTION TREE PER LANDSCAPE PLANS NOTES: 1.PERMEABLE SURFACING SHALL BE FLEXI-PAVE POROUS FLEXIBLE PAVING OR APPROVED EQUIVALENT. INSTALL PER MANUFACTURES SPECIFICATIONS. 2.COORDINATE AND CONFIRM ALL WORK ASSOCIATED WITH EXISTING AND PROPOSED TREES WITH LANDSCAPE ARCHITECT. FOR EXISTING TREES, COORDINATE PAVEMENT REMOVAL, PREPARATION, AND PAVEMENT PLACEMENT AROUND TRUNK AND FLARE WITH ARBORIST TO PROTECT AND PREVENT DAMAGE TREES. AT EXISTING TREES AT PROPOSED TREES 1' - 4 " 1" TYP 8" REFER TO LS PLANS FOR DETAILING OF PAVEMENT RELATIONSHIP TO TRUNK AND FLARE. 1/2" POLYETHYLENE FOAM EXPANSION JOINT MATERIAL WRAPPED AROUND TREE TRUNK. REFER TO LS PLANS FOR DETAILING OF PAVEMENT RELATIONSHIP TO TRUNK AND FLARE. 1/2" POLYETHYLENE FOAM EXPANSION JOINT MATERIAL WRAPPED AROUND TREE TRUNK. REFER TO LS PLANS FOR DETAILING OF PAVEMENT RELATIONSHIP TO TRUNK AND FLARE. 1" OF LOOSE 3/8" RUBBER GRANULE WITH NO BINDER IN AN 18" DIAMETER CIRCLE AROUND TREE TRUNK. R-433419 3STANDARD PARKING STALL NTS 4"6"6" 30 " 6' - 0 " 3' - 6 " LE N G T H P A I N T E D Y E L L O W CONCRETE GALVANIZED STEEL FILLED WITH CONCRETE 4FIXED BOLLARD NTS NOTES: 1.SCHEDULE 40 OR BETTER GALVANIZED STEEL PIPE FILLED WITH CONCRETE, 6 FEET x 4 INCHES IN DIAMETER. THE CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI AFTER 28 DAYS. THE EXPOSED SECTION OF THE POST SHALL BE PAINTED TRAFFIC YELLOW. 2025-07-15 DEVELOPMENT ENGINEERING msippo 08/13/2025 2CEMENT CONCRETE DRIVEWAY NOTES NTS 3CEMENT CONCRETE CURBS NTS PAVING DETAILCall 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 R-433420 1CEMENT CONCRETE SIDEWALK NTS 2025-07-15 DEVELOPMENT ENGINEERING msippo 08/13/2025 2TYPICAL LONGITUDINAL PATCH NTS 3TYPICAL CONCRETE PATCH NTS PAVING DETAILCall 811two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 R-433421 1TYPICAL TRANSVERSE PATCH NTS 2025-07-15 DEVELOPMENT ENGINEERING msippo 08/13/2025 Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 PAVING DETAIL R-433422 2INTERSECTION CROSSWALK NTS 1MID-BLOCK CROSSWALK NTS 2025-07-15 DEVELOPMENT ENGINEERING msippo 08/13/2025 U U U U U U UUUU T T SS (RECORD) SS (RECORD)SS (RECORD) SS (RECORD) SS (RECORD) SS (RECORD) P P P P P P P P P YD SOLID COVER RIM 36.44 IE 33.8 SE, 8" IRON W W W SS SS GP GP GP GP GP GP GP GP SS W W W W W GP GP GP GP W SS SS GP GP KB-10 LID 35.38 ELEV 35.11 @ TOP OF PVC MW-6 LID 37.00 ELEV 36.69 @ TOP OF PVC W GP GPGP GP GP GP GP GP GP GP GP GP W GP GP GP GP GPGPGP GPGPGPGPGPGPGPGPGPGPGPGPGPGPGP GP GP SS GP&LITE GP J11-2 CB 1 S 3RD STREET LO G A N A V E S BU R N E T T A V E S LIMIT OF WORK 569600-0050 000720-0188 PROPERTY LINE SPU P, HEADER SPU W, 66" 569600-0055 569600-0120569600-0065 MATCH LINE EXISTING PEDESTRIAN LIGHTS TO REMAIN PROPOSED CATENARY POLES, TYP. PROPOSED MAST LIGHT POLES EXISTING PEDSTRIAN LIGHTS TO BE REMOVED DASHED LINE REPRESENTS ZONE WHEREIN NO PROPOSED TREES OR LIGHT POLE FOOTINGS ARE LOCATED. CLEAR AREA IS 10' FROM EDGE OF SPU WATER PIPES, 5' FROM SPU HEADER CABLE, TYP. SPU W, 51.5" SPU W, 12" 10' - 0" 10' - 0" 15' - 5" 21' - 2" 24' - 3" 25' - 4" 49' - 9 1/2" TRENCHING FOR CATENARY ELECTRICAL CONNECTIONS, REFER TO CIVIL AND ELECTRICAL PLANS 1. REFER TO CIVIL DRAWINGS FOR ALL EXISTING AND PROPOSED UTILITY LINES, POLES, METERS, VAULTS, AND STRUCTURES. 2. REFER TO CIVIL DRAWINGS FOR ALL HARDSCAPE GRADING INFORMATION. 3. REPORT ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND ACTUAL FIELD CONDITIONS TO LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION/INSTALLATION. GENERAL NOTES 1" = 20'-0"1 LANDSCAPE KEY PLAN 0 10'20' MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61LANDSCAPE KEY PLAN CIVIL CONSTRUCTION PERMIT L0.00 07/16/25 23 R-433423 SHEET INDEX L0.00 LANDSCAPE KEY PLAN L0.01 TREE RETENTION PLAN - MARKET L0.02 TREE RETENTION PLAN - PIAZZA L0.11 SELECTIVE DEMOLITION PLAN - MARKET L0.12 SELECTIVE DEMOLITION PLAN - PIAZZA L0.13 SELECTIVE DEMOLITION PLAN ENLARGEMENTS - MARKET L0.14 SELECTIVE DEMOLITION PLAN ENLARGEMENTS - PIAZZA L1.01 MATERIALS PLAN - MARKET L1.02 MATERIALS PLAN - PIAZZA L2.02 GRADING PLAN - PIAZZA L3.01A PLANTING PLAN - MARKET - TREES + GC L3.01B PLANTING PLAN - MARKET - SHRUBS + PERENNIALS L3.02A PLANTING PLAN - PIAZZA - TREES + GC L3.02B PLANTING PLAN - PIAZZA - SHRUBS + PERENNIALS L3.03 PLANTING SCHEDULE L3.04 PLANTING DETAILS L3.05 PLANTING DETAILS L3.06 PLANTING DETAILS L4.01 IRRIGATION PLAN - MARKET L4.02 IRRIGATION PLAN - PIAZZA L4.03 IRRIGATION DETAILS L4.04 IRRIGATION DETAILS L5.01 MATERIALS DETAILS L5.02 MATERIALS DETAILS L6.01 LAYOUT PLAN - MARKET L6.02 LAYOUT PLAN - PIAZZA L6.03 LAYOUT PLAN - PIAZZA SCORING AND JOINTING ENLARGEMENT - WEST L6.04 LAYOUT PLAN - PIAZZA SCORING AND JOINTING ENLARGEMENT - EAST amorganroth 08/12/2025 CURRENT PLANNING DEVELOPMENT ENGINEERING msippo 08/13/2025 1. REFER TO ARBORIST REPORT INCLUDED WITH BID PACKAGE. 2. PROVIDE TREE PROTECTION FENCING PER TREE PROTECTION SITE PLAN. 3. TREE REPLACEMENT IS NOT REQUIRED ON THIS PROJECT SINCE THE PROJECT MEETS THE 30% TREE RETENTION MINIMUM. 40 TREE CREDITS REQUIRED 112.5 TREE CREDITS PROVIDED NOTES MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61TREE RETENTION PLAN - MARKET CIVIL CONSTRUCTION PERMIT L0.01 07/16/25 24 R-433424 3" = 1'-0"1 TREE PROTECTION ZONE AND SIGNAGE TREES 44-46, 49-51 ARE ON ADJACENT PROPERTY AND NOT COUNTED TOWARDS TREE RENTENTION CREDITS TREES 41-43 ARE IN LOGAN AVE S ROW AND NOT COUNTED TOWARDS TREE RENTENTION CREDITS TREES 55-60 ARE IN BURNETT AVE S ROW AND NOT COUNTED TOWARDS TREE RENTENTION CREDITS amorganroth 08/12/2025 CURRENT PLANNING DEVELOPMENT ENGINEERING msippo 08/13/2025 1. REFER TO ARBORIST REPORT INCLUDED WITH BID PACKAGE. 2. PROVIDE TREE PROTECTION FENCING PER TREE PROTECTION SITE PLAN. 3. TREE REPLACEMENT IS NOT REQUIRED ON THIS PROJECT SINCE THE PROJECT MEETS THE 30% TREE RETENTION MINIMUM. 40 TREE CREDITS REQUIRED 112.5 TREE CREDITS PROVIDED NOTES MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61TREE RETENTION PLAN - PIAZZA CIVIL CONSTRUCTION PERMIT L0.02 07/16/25 25 R-433425 3" = 1'-0"1 TREE PROTECTION ZONE AND SIGNAGE TREES 1-6 ARE IN S 3RD ST ROW AND NOT COUNTED TOWARDS TREE RENTENTION CREDITS amorganroth 08/12/2025 CURRENT PLANNING DEVELOPMENT ENGINEERING msippo 08/13/2025 U U U U T T SS (RECORD) SS (RECORD)SS (RECORD) SS (RECORD) P P P P P P 216 227 231 311 312 314 319 332 339 366 369 313 SS SS GP GP GP GP GP SS SS SS GP GP GP GP GPGP GP GPGPGPGPGPGPGPGPGPGPGPGPGPGPGP GP GP SS GP&LITE GP REMOVE AT EXPANSION JOINT SAWCUT NOT AT A JOINT CONCRETE CUTTING LEGEND SAWCUT AT NEAREST JOINT 1 2 3 4 5 6 7 8 9 10 11 12 G (485 SF) PROPERTY LINE LIMIT OF WORK MATCH LINE, SEE SHEET L0.12 L0.13 2 L0.13 3 NOTE: FULL CONCRETE ROAD PANEL RESTORATION REQUIRED WHERE EXISTING CONCRETE ROADWAY IS DISTURBED. REFER TO CIVIL DWGS 1. TRANSPORT SALVAGED ITEMS TO THE CITY OF RENTON MAINTENANCE SHOP LOCATED AT 107 WILLIAMS AVE N, RENTON, WA 98057. 2. SALVAGE EXISTING TRASH RECEPTACLES. SALVAGED TRASH RECEPTACLES ARE TO BE REFURBISHED, REPAINTED (COLOR TBD), AND REINSTALLED PER THE LOCATIONS SHOWN ON THE MATERIALS AND LAYOUT PLANS. 3. REFER TO SHEET L4.02 AND CIVIL DRAWINGS FOR EXTENTS OF EXISTING IRRIGATION SYSTEM TO BE DEMOLISHED. 4. REFER TO ELECTRICAL DRAWINGS FOR EXTENTS OF EXISTING ELECTRICAL SYSTEM TO BE DEMOLISHED. DEMOLITION NOTES MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61SELECTIVE DEMOLITION PLAN - MARKET CIVIL CONSTRUCTION PERMIT L0.11 07/16/25 26 R-433426 0 5'10' 1" = 10'-0"1 SELECTIVE DEMOLITION KEY PLAN - MARKET DEVELOPMENT ENGINEERING msippo 08/13/2025 U U U UUUU SS (RECORD) SS (RECORD)SS (RECORD) SS (RECORD) SS (RECORD) SS (RECORD) P P W SS W W W W W GP GP GP GP SS W J11-2 CB 1 AL AL AL S 3RD STREET LO G A N A V E S BU R N E T T A V E S PROPERTY LINE LIMIT OF WORK L0.14 1 L0.14 2 L0.14 3 L0.14 4 L0.14 5 MATCH LINE, SEE SHEET L0.11 SALVAGE EXISTING PLAQUE #1 7 L0.14 SALVAGE EXISTING STONE SIGN #1 12 L0.14 SALVAGE EXISTING SCULPTURE #1 11 L0.14 SALVAGE EXISTING PLAQUE #3 9 L0.14 SALVAGE EXISTING PLAQUE #2 8 L0.14 SALVAGE EXISTING PLAQUE #4 10 L0.14 EXISTING SIGN TO REMAIN EXISTING TRASH RECEPTACLE, REFURBISH AND REINSTALL AT SAME LOCATION EXISTING TRASH RECEPTACLE, REFURBISH AND REINSTALL AT SAME LOCATION SALVAGE EXISTING TRASH RECEPTACLE AND REINSTALL PER PLANS SALVAGE EXISTING TRASH RECEPTACLE AND REINSTALL PER PLANS SALVAGE EXISTING DRINKING FOUNTAIN AND REINSTALL AT NEW LOCATION, REFER TO MATERIALS PLANS SALVAGE EXISTING TRASH RECEPTACLE AND REINSTALL PER PLANS SALVAGE EXISTING TRASH RECEPTACLE AND REINSTALL PER PLANS PRESERVE EXISTING CONCRETE SEAT WALLS AND BOULDERS THAT ARE CAST INTO THE WALLS AT THESE LOCAITONS NOTE: FULL CONCRETE ROAD PANEL RESTORATION REQUIRED WHERE EXISTING CONCRETE ROADWAY IS DISTURBED. REFER TO CIVIL DWGS REFER TO CIVIL PLANS FOR EXTENT OF WORK ON SOUTH 3RD STREET ROW REMOVE AT EXPANSION JOINT SAWCUT NOT AT A JOINT CONCRETE CUTTING LEGEND SAWCUT AT NEAREST JOINT 1. TRANSPORT SALVAGED ITEMS TO THE CITY OF RENTON MAINTENANCE SHOP LOCATED AT 107 WILLIAMS AVE N, RENTON, WA 98057. 2. SALVAGE EXISTING TRASH RECEPTACLES. SALVAGED TRASH RECEPTACLES ARE TO BE REFURBISHED, REPAINTED (COLOR TBD), AND REINSTALLED PER THE LOCATIONS SHOWN ON THE MATERIALS AND LAYOUT PLANS. 3. REFER TO SHEET L4.02 AND CIVIL DRAWINGS FOR EXTENTS OF EXISTING IRRIGATION SYSTEM TO BE DEMOLISHED. 4. REFER TO ELECTRICAL DRAWINGS FOR EXTENTS OF EXISTING ELECTRICAL SYSTEM TO BE DEMOLISHED. DEMOLITION NOTES MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61SELECTIVE DEMOLITION PLAN - PIAZZA CIVIL CONSTRUCTION PERMIT L0.12 07/16/25 27 R-433427 1" = 10'-0"1 SELECTIVE DEMOLITION KEY PLAN - PIAZZA 0 10'20' DEVELOPMENT ENGINEERING msippo 08/13/2025 REMOVE AT EXPANSION JOINT SAWCUT NOT AT A JOINT CONCRETE CUTTING LEGEND SAWCUT AT NEAREST JOINT MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61 SELECTIVE DEMOLITION PLAN ENLARGEMENTS - MARKET CIVIL CONSTRUCTION PERMIT L0.13 07/16/25 28 R-433428 1/4" = 1'-0"2 ENLARGEMENT 6 1/4" = 1'-0"1 MARKET SIDE SEWER 1/4" = 1'-0"3 ENLARGEMENT 7 DEVELOPMENT ENGINEERING msippo 08/13/2025 AL AL AL REMOVE AT EXPANSION JOINT SAWCUT NOT AT A JOINT CONCRETE CUTTING LEGEND SAWCUT AT NEAREST JOINT CORE (3) 12" DIAMTER SUMP HOLES IN BASE OF FOUNTAIN, EXTENDING 12" DEEP BELOW BOTTOM OF CONCRETE FOUNTAIN SLAB. FILL WITH DRAIN ROCK NOTE: FINISH GRADES TO BE ADA COMPLIANT 1/4" 1/ 4 " GRIND CORNER EXISTING CONCRETE PAVING TO REMAIN EXISTING CONCRETE PAVING TO BE REMOVED MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61 SELECTIVE DEMOLITION PLAN ENLARGEMENTS - PIAZZA CIVIL CONSTRUCTION PERMIT L0.14 07/16/25 29 R-433429 1/4" = 1'-0"1 ENLARGEMENT 1 1/4" = 1'-0"2 ENLARGEMENT 2 1/4" = 1'-0"3 ENLARGEMENT 3 1/4" = 1'-0"4 ENLARGEMENT 4 1/4" = 1'-0"5 ENLARGEMENT 5 REMOVE UPPER FOUNTAIN BOWL ABOVE CONCRETE PODIUM 3" = 1'-0"6 SAWCUT AT EXISTING CONCRETE 1/4" = 1'-0"12 STONE SIGN #1 1/4" = 1'-0"11 SCULPTURE #1 1/4" = 1'-0"7 PLAQUE #1 1/4" = 1'-0"8 PLAQUE #2 1/4" = 1'-0"9 PLAQUE #3 1/4" = 1'-0"10 PLAQUE #4 DEVELOPMENT ENGINEERING msippo 08/13/2025 U U U U T T SS (RECORD) SS (RECORD)SS (RECORD) SS (RECORD) GAS METER ASSEMBLY P P P P P P 2' YD SOLID COVER RIM 36.44 IE 33.8 SE, 8" IRON SS SS GP GP GP GP SS SS SS GP GP GP GP GPGP GP GPGPGPGPGPGPGPGPGPGPGPGPGPGPGP GP GP SS GP&LITE GP LO G A N A V E S BU R N E T T A V E S PA (645 SF) 2A DRIVEWAY, SEE CIVIL LIMIT OF WORK PROPERTY LINE MATCH LINE, SEE SHEET L1.02 SEWER, SEE CIVIL 2A TRENCH DRAIN, SEE CIVIL. 4 4 REFER TO ARCH DWGS FOR EAST/WEST PAVING CUT LINE LOCATION. SAWCUT TO THE NEAREST JOINT SOUTH CUT LINE OF NEW PAVING TO ALIGN WITH PLANTER EXTENTS REFURBISHED PLANTING AREA TO MATCH CURRENT EXTENTS. MAINTAIN EXISTING GRADES. REMOVABLE BOLLARDS REMOVABLE BOLLARDS MOUNTING PLATES, REFER TO CIVIL FOR LAYOUT CURB AND ROADWAY PER CIVIL 2A 6 L5.01 3 3 2C2C2C2C2C2A2A 2A2A2A 2A REFER TO CIVIL DWGS FOR EAST/WEST PAVING CUT LINE LOCATION. SAWCUT TO THE NEAREST JOINT 6 L5.01 1 REFER TO ARCH DWGS FOR ENCLOSURE TYPE 1 NEW CIP CONCRETE PAVEMENT WITH CITY OF RENTON STANDARD SIDEWALK SCORING AND FINISH 1 MATERIALS LEGEND -MARKET EXISTING TREE TO REMAIN. PROTECT IN PLACE WITH CITY STANDARD TREE PROTECTION. REFER TO L0.01 FOR TREE REMOVALS, PROTECTION MEASURES, AND CALCULATIONS TYPE 2A NEW CIP CONCRETE PAVEMENT WITH INTEGRAL COLOR AND SEALED MEDIUM TOP-CAST FINISH. COLOR: REFER TO NOTE 2 THIS SHEET. 2A PLANTING AREA. SOIL MIN. 18" DEPTH AND INCREASED TO 36" DEPTH AT TREES, WITH 2" ORGANIC MULCH -SEE SPEC SECTION 32 91 20 PA PREFABRICATED METAL PLANTER, BASIS OF DESIGN: TOURNESOL 'WILSHIRE' WITH PAINTED MILD STEEL FINISH 4 (2) @ 2' x 2' x 8' (2) @ 2' x 2' x 10' 1 L3.04 1 L5.01 3 L3.04 EXISTING CIP CONCRETE PAVEMENT TO REMAIN. CLEAN SURFACE, SEE NOTE 2. REMOVE AND/OR GRIND SMOOTH ANY ATTACHED ELEMENTS 3 TYPE 2C NEW CIP CONCRETE PAVEMENT WITH INTEGRAL COLOR AND SEALED MEDIUM TOP-CAST FINISH. COLOR: REFER TO NOTE 2 THIS SHEET. 2C1 L5.01 1. ALL PEDESTRIAN PAVEMENTS SHALL BE SEALED WITH A MATTE FINISH PENETRATING SEALER. REFER TO SPECIFICATION 033525. 2. CLEANED EXISTING PAVEMENT WILL BE THE BASIS OF COMPARISON FOR MOCK-UPS OF CONCRETE TYPES 2A, 2B, AND 2C. 3. AVOID DISTURBANCE OF EXISTING TREES PER ARBORIST RECOMMENDAITONS. REFER TO ARBORIST REPORT FOR EXTENT OF EXISTING TREE CRITICAL ROOT ZONES. 4. AVOID DISTURBANCE OF EXISTING IRRIGATION TO REMAIN, REFER TO IRRIGATION PLANS FOR EXTENTS. 5. REFURBISH SALVAGED DRINKING FOUNTAIN. INSTALL SHIMS AS NEEDED TO ENSURE FOUNTAIN IS PLUMB MATERIALS NOTES MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61MATERIALS PLAN - MARKET CIVIL CONSTRUCTION PERMIT L1.01 07/16/25 30 R-433430 1" = 10'-0"1 MATERIALS PLAN - MARKET 0 5'10' DEVELOPMENT ENGINEERING msippo 08/13/2025 U U U UUUU SS (RECORD) SS (RECORD)SS (RECORD) SS (RECORD) SS (RECORD) SS (RECORD) P P YD SOLID COVER RIM 36.44 IE 33.8 SE, 8" IRON W SS W W W W W GP GP GP GP SS W J11-2 CB 1 S 3RD STREET LO G A N A V E S BU R N E T T A V E S 2AL PA 59 7 7 7 788 8 8 8 8 MATCH LINE, SEE SHEET L1.01 PROPERTY LINE (593 SF) (1165 SF) (1999 SF) (1210 SF) (370 SF) (353 SF) (668 SF) (621 SF) (194 SF) (1044 SF) PAVEMENT IS CONTINUOUS UNDER WOOD SEATING STRUCTURE 4 44 PAVEMENT IS CONTINUOUS UNDER WOOD SEATING PLATFORMS, TYP. LIMIT OF WORK REINSTALL REFURBISHED FOUNTAIN, SEE NOTE 5 THIS SHEET SALVAGED AND REFURBISHED TRASH RECEPTACLE SALVAGED AND REFURBISHED TRASH RECEPTACLE SALVAGED AND REFURBISHED TRASH RECEPTACLE SALVAGED AND REFURBISHED TRASH RECEPTACLE STUMPERY4 L5.02 2A 7 FILL EXISTING BASINS WITH CONCRETE, FLUSH TO TOP OF EXISTING CONCRETE. ENSURE POSITIVE DRAINAGE. 4 L5.02 9 EXISTING TREE CRITICAL ROOT ZONE, TYP. REFER TO ARBORIST REPORT 2A 2A 2A 3 33 2C 2B2A2B2B10 2A 2A 2A 2B (282 SF) (498 SF) SALVAGED AND REFURBISHED TRASH RECEPTACLE SALVAGED AND REFURBISHED TRASH RECEPTACLE LANDSCAPE ELECTRICAL RECEPTACLE IN LOCKABLE TAMPER PROOF BOX WITH WHILE-IN-USE COVER, TYP. REFER TO ELEC DWGS 4 4 TYP 6A TYP 6B 10 2A3 1 2A PROTECT EXISTING PLANTS AND SOIL IN MEDIAN DURING INSTALLATION OF NEW VEHICULAR PAVEMENT 2A 2A 2A 2A 2B 2B ELECTRICAL DISCONNECT FOR RECEPTACLES MOUNTED IN CATENARY POLES ON THE EAST SIDE OF LOGAN AVE SOUTH. IN LOCKABLE TAMPER PROOF BOX WITH INTERCHANGEABLE LOCKING CORE. LOCK MANUFCTURER: "BEST". REFER TO ELEC DWGS MATERIALS LEGEND -PIAZZA TYPE 1 NEW CIP CONCRETE PAVEMENT WITH CITY OF RENTON STANDARD SIDEWALK SCORING AND FINISH 1 EXISTING TREE TO REMAIN. PROTECT IN PLACE WITH CITY STANDARD TREE PROTECTION. REFER TO L0.02 FOR TREE REMOVALS, PROTECTION MEASURES, AND CALCULATIONS TYPE 2A NEW CIP CONCRETE PAVEMENT WITH INTEGRAL COLOR AND SEALED MEDIUM TOP-CAST FINISH. COLOR: REFER TO NOTE 2 THIS SHEET. 2A POROUS FLEXIBLE SURFACE9TYPE 1 WOOD TOPPED SEATING STRUCTURE: BASIS OF DESIGN: 20' Ø COLUMBIA CASCADE "ROUND PLATFORM SEAT" 5 TYPE 2B WOOD TOPPED SEATING STRUCTURES: BASIS OF DESIGN COLUMBIA CASCADE "ROUND PLATFORM SEAT", 48" Ø 6B PLANTING AREA. SOIL MIN. 18" DEPTH AND INCREASED TO 36" DEPTH AT TREES, WITH 2" ORGANIC MULCH -SEE SPEC SECTION 32 91 20 PA SODDED LAWNL MAST LIGHT POLES, SEE ELECTRICAL PLANS. COLOR BE "RAL 9005TX"7 CATENARY LIGHT POLES, SEE ELECTRICAL PLANS. COLOR BE "RAL 9005TX"8 1 L5.01 2 L3.04 1 L3.04 CIP CONCRETE FLUSH PLANTER CURB4 2 L5.01 EXISTING CIP CONCRETE PAVEMENT TO REMAIN. CLEAN SURFACE, SEE NOTE 2. REMOVE AND/OR GRIND SMOOTH ANY ATTACHED ELEMENTS 3 TYPE 2B NEW CIP CONCRETE PAVEMENT WITH INTEGRAL COLOR AND SEALED MEDIUM TOP-CAST FINISH. COLOR: REFER TO NOTE 2 THIS SHEET. 2B1 L5.01 TYPE 2C NEW CIP CONCRETE PAVEMENT WITH INTEGRAL COLOR AND SEALED MEDIUM TOP-CAST FINISH. COLOR: REFER TO NOTE 2 THIS SHEET. 2C1 L5.01 SOIL CELLS10 5 L5.02 3 L5.02 1 L3.06 TYPE 2A WOOD TOPPED SEATING STRUCTURES: BASIS OF DESIGN COLUMBIA CASCADE "ROUND PLATFORM SEAT" WITH 72" Ø BOTTOM TIER, 36" Ø UPPER TIER 6A 3 L5.01 4 L5.01 5 L5.01 1. ALL PEDESTRIAN PAVEMENTS SHALL BE SEALED WITH A MATTE FINISH PENETRATING SEALER. REFER TO SPECIFICATION 033525. 2. CLEANED EXISTING PAVEMENT WILL BE THE BASIS OF COMPARISON FOR MOCK-UPS OF CONCRETE TYPES 2A, 2B, AND 2C. 3. AVOID DISTURBANCE OF EXISTING TREES PER ARBORIST RECOMMENDAITONS. REFER TO ARBORIST REPORT FOR EXTENT OF EXISTING TREE CRITICAL ROOT ZONES. 4. AVOID DISTURBANCE OF EXISTING IRRIGATION TO REMAIN, REFER TO IRRIGATION PLANS FOR EXTENTS. 5. REFURBISH SALVAGED DRINKING FOUNTAIN. INSTALL SHIMS AS NEEDED TO ENSURE FOUNTAIN IS PLUMB MATERIALS NOTES N O T F O R C O N S T R U C T I O N F O R R E F E R E N C E O N L Y MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT ING T O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . TT H E W M.PO R T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 62 1 CIVIL PERMIT CORRECTIONS 1 9/15/2025 MATERIALS PLAN - PIAZZA 100% CONSTRUCTION DOCUMENTS L1.02 02/10/2025 31 R-433431 1" = 10'-0"1 MATERIALS PLAN - PIAZZA 0 5'10' 1 DEVELOPMENT ENGINEERING msippo 10/02/2025 J11-2 CB 1 36.8 3 7 . 2 3 7 .4 36.6 37.4 3 7.2 37.6 37.8 3 8 .2 3 8 .4 38.6 38.8 38 .6 38.438.2 3 7 .8 37.6 37.0 3 8 .0 38.0 LO G A N A V E S S 3RD STREET BU R N E T T A V E S 37.60 37.80 38.00 38.20 HP 38.40 37.80 38.40 38.60 38.20 37.20 37.40 37.60 37.80 38.60 38.60 38.80 36.95 36.59 36.55 36.58 36.68 38.79 37.58 STORM 37.50 38.48 38.92 38.55 38.86 2 % 3 . 1 % 40.00 41.00 42.00 38.56 38.59 38.00 37.40 37.60 38.40 38.60 38.80 38.80 37.00 36.80 36.60 37.80 37.36 37.20 37.00 37.46 37.60 37.88 36.80 37.00 37.20 37.40 38.00 38.60 38.80 39.00 38.80 38.40 RESHAPE TOPOGRAPHY TO MATCH PAVEMENT GRADES AS NECESSARY. MINIMIZE DISTURBANCE TO CRITICAL ROOT ZONES.38.89 38.5238.4238.43 38.72 39.08 39.01 38.47 38.80 38.89 38.96 38.22 EXISTING TREE CRITICAL ROOT ZONE, TYP. HP 37.80 HP 37.40 3.3% 3.7 % PROPERTY LINE LIMIT OF WORK REFER TO CIVIL PLANS FOR EXTENT OF WORK ON SOUTH 3RD STREET ROW LEGEND -GRADING PROPOSED ELEVATION HP XXX.XX HIGH POINT OF SOIL ELEVATION XXX.XX XX %PROPOSED SLOPE LP XXX.XX LOW POINT ELEVATION SURVEY REFERENCE ELEVATION, SEE CIVILXXX.XX 1. REFERENCE CIVIL SHEETS FOR ALL HARDSCAPE GRADING. 2. CALL THE UTILITIES UNDERGROUND LOCATION CENTER FOR FIELD LOCATION OF ALL UTILITIES. DO NOT PERFORM ANY EXCAVATION OR OTHER GRADING OPERATIONS PRIOR TO THEIR LOCATION. 3. SLOPE FINISHED SURFACE A MINIMUM OF 2% AWAY FROM THE BUILDING ON ALL SIDES UNLESS NOTED OTHERWISE. 4. COORDINATE FINE GRADING AND SURFACE DRAINAGE WITH LANDSCAPE INSTALLATION. SEE MATERIALS PLANS AND ARCHITECTURAL PLANS FOR HARDSCAPE, LANDSCAPE FEATURES, AND PLANTING AREAS. GRADING NOTES MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61GRADING PLAN - PIAZZA CIVIL CONSTRUCTION PERMIT L2.02 07/16/25 32 R-433432 1" = 10'-0"1 GRADING PLAN - PIAZZA 0 5'10' DEVELOPMENT ENGINEERING msippo 08/13/2025 U U U U T T SS (RECORD) SS (RECORD)SS (RECORD) SS (RECORD) P P P P P P 2'2'2'2' YD SOLID COVER RIM 36.44 IE 33.8 SE, 8" IRON SS SS GP GP GP GP GP SS SS SS GP GP GP GP GPGP GP GPGPGPGPGPGPGPGPGPGPGPGPGPGPGP GP GP SS GP&LITE GP LO G A N A V E S BU R N E T T A V E S LIMIT OF WORK PROPERTY LINE MATCH LINE, SEE SHEET L3.02A INSTALL ARBORIST MULCH AT EXISTING TREE TO BE REMOVED 1. REFER TO CIVIL DRAWINGS FOR UTILITY INFORMATION. 2. ALL IN-GRADE PLANTED AREAS TO RECEIVE PERMANENT IRRIGATION. 3. AIRATE AND APPLY SLOW RELEASE FERTILIZER AT ROOT ZONE OF EXISTING TREES TO REMAIN PRIOR TO INSTALLATION OF FLEXIBLE POROUS SURFACING. 4. REFER TO DETAIL L3.05/7 FOR 2-SPECIES GROUNDCOVER PLANTING DETAIL. PLANTING NOTES MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61PLANTING PLAN - MARKET - TREES + GC CIVIL CONSTRUCTION PERMIT L3.01A 07/16/25 33 R-433433 1" = 10'-0"1 PLANTING PLAN - MARKET - TREES + GC 0 5'10' amorganroth 08/12/2025 CURRENT PLANNING DEVELOPMENT ENGINEERING msippo 08/13/2025 U U U U T T SS (RECORD) SS (RECORD)SS (RECORD) SS (RECORD) P P P P P P 2'2' YD SOLID COVER RIM 36.44 IE 33.8 SE, 8" IRON SS SS GP GP GP GP GP SS SS SS GP GP GP GP GPGP GP GPGPGPGPGPGPGPGPGPGPGPGPGPGPGP GP GP SS GP&LITE GP LO G A N A V E S BU R N E T T A V E S LIMIT OF WORK PROPERTY LINE MATCH LINE, SEE SHEET L3.02B 1. REFER TO CIVIL DRAWINGS FOR UTILITY INFORMATION. 2. ALL IN-GRADE PLANTED AREAS TO RECEIVE PERMANENT IRRIGATION. 3. AIRATE AND APPLY SLOW RELEASE FERTILIZER AT ROOT ZONE OF EXISTING TREES TO REMAIN PRIOR TO INSTALLATION OF FLEXIBLE POROUS SURFACING. 4. REFER TO DETAIL L3.05/7 FOR 2-SPECIES GROUNDCOVER PLANTING DETAIL. PLANTING NOTES MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61 PLANTING PLAN - MARKET - SHRUBS + PERENNIALS CIVIL CONSTRUCTION PERMIT L3.01B 07/16/25 34 R-433434 0 5'10' 1" = 10'-0"1 PLANTING PLAN - MARKET - SHRUBS + PERENNIALS amorganroth 08/12/2025 CURRENT PLANNING DEVELOPMENT ENGINEERING msippo 08/13/2025 U U U UUUU SS (RECORD) SS (RECORD)SS (RECORD) SS (RECORD) SS (RECORD) SS (RECORD) P P 3' BARKBARKBARK BARK BARK BARK/DIRT YD SOLID COVER RIM 36.44 IE 33.8 SE, 8" IRON W SS W W W W W GP GP GP GP SS W S 3RD STREET LO G A N A V E S BU R N E T T A V E S LIMIT OF WORK PROPERTY LINE EXTENT OF SOIL CELLS MATCH LINE, SEE SHEET L3.01A 1 L3.06 SPU P, HEADER SPU W, 66" DASHED LINE REPRESENTS ZONE WHEREIN NO PROPOSED TREES OR LIGHT POLE FOOTINGS ARE LOCATED. CLEAR AREA IS 10' FROM EDGE OF SPU WATER PIPES, 5' FROM SPU HEADER CABLE, TYP. SPU W, 51.5" SPU W, 12" 7' - 0" 15' - 1" 11' - 0" 15' - 10" 6' - 4" 21' - 3" 10' - 0" 5' - 0" 1. REFER TO CIVIL DRAWINGS FOR UTILITY INFORMATION. 2. ALL IN-GRADE PLANTED AREAS TO RECEIVE PERMANENT IRRIGATION. 3. AIRATE AND APPLY SLOW RELEASE FERTILIZER AT ROOT ZONE OF EXISTING TREES TO REMAIN PRIOR TO INSTALLATION OF FLEXIBLE POROUS SURFACING. 4. REFER TO DETAIL L3.05/7 FOR 2-SPECIES GROUNDCOVER PLANTING DETAIL. PLANTING NOTES MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61PLANTING PLAN - PIAZZA - TREES + GC CIVIL CONSTRUCTION PERMIT L3.02A 07/16/25 35 R-433435 1" = 10'-0"1 PLANTING PLAN - PIAZZA - TREES + GC 0 5'10' amorganroth 08/12/2025 CURRENT PLANNING DEVELOPMENT ENGINEERING msippo 08/13/2025 U U U UUUU SS (RECORD) SS (RECORD)SS (RECORD) SS (RECORD) SS (RECORD) SS (RECORD) P P 3' BARKBARKBARK BARK BARK BARK/DIRT YD SOLID COVER RIM 36.44 IE 33.8 SE, 8" IRON W SS W W W W W GP GP GP GP SS W S 3RD STREET LO G A N A V E S BU R N E T T A V E S PROPERTY LINE MATCH LINE, SEE SHEET L3.01B LIMIT OF WORK 1. REFER TO CIVIL DRAWINGS FOR UTILITY INFORMATION. 2. ALL IN-GRADE PLANTED AREAS TO RECEIVE PERMANENT IRRIGATION. 3. AIRATE AND APPLY SLOW RELEASE FERTILIZER AT ROOT ZONE OF EXISTING TREES TO REMAIN PRIOR TO INSTALLATION OF FLEXIBLE POROUS SURFACING. 4. REFER TO DETAIL L3.05/7 FOR 2-SPECIES GROUNDCOVER PLANTING DETAIL. PLANTING NOTES MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61PLANTING PLAN - PIAZZA - SHRUBS + PERENNIALS CIVIL CONSTRUCTION PERMIT L3.02B 07/16/25 36 R-433436 1" = 10'-0"1 PLANTING PLAN - PIAZZA - SHRUBS + PERENNIALS 0 5'10' amorganroth 08/12/2025 CURRENT PLANNING DEVELOPMENT ENGINEERING msippo 08/13/2025 MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61PLANTING SCHEDULE CIVIL CONSTRUCTION PERMIT L3.03 07/16/25 37 R-433437 PLANTING SCHEDULE - GROUNDCOVERS - MARKET QTY BOTANICAL NAME COMMON NAME SIZE SPACING COMMENTS 37 Fragaria chiloensis Beach Strawberry 4" POT 24" O.C.PRIMARY GROUNDCOVER 15 Mahonia nervosa Cascade Mahonia #2 POT 24" O.C. SECONDARY GROUNDCOVER 110 Polystichum munitum Western Sword Fern #1 POT 18" O.C. 19 Blechnum chilense Chilean Hard Fern #2 POT 24" O.C. SECONDARY GROUNDCOVER 55 Gaultheria shallon Salal #2 POT 24" O.C. PRIMARY GROUNDCOVER PLANTING SCHEDULE - SHRUBS, PERENNIALS, GRASSES, AND VINES - MARKET QTY BOTANICAL NAME COMMON NAME SIZE SPACING COMMENTS DECIDUOUS SHRUB 5 Cornus sanguinea 'Midwinter Fire' Dogwood 'Midwinter Fire' #5 POT PER PLAN 3 Philadelphus lewesii 'Blizzard' 'Blizzard' Lewis's mock orange #7 POT PER PLAN EVERGREEN SHRUB 3 Mahonia aquifolium 'Compacta' Compact Oregon Grape #5 POT PER PLAN PERENNIAL 17 Achillea millefolium New Vintage White Yarrow #1 POT PER PLAN 13 Campanula rotundifolia Bluebell #1 POT PER PLAN 22 Dichelostemum congestum Ookow #5 POT PER PLAN 12 Geranium x cantabrigiense 'Biokovo' Cranesbill 'Biokovo' #1 POT PER PLAN 23 Geranium x riversleaianum 'Mavis Simpson' Crane's Bill 'Mavis Simpson' #2 POT PER PLAN 10 Helleborus x ericsmithii 'HGC Monte Criso' Hellebore Snow Rose #2 POT PER PLAN 11 Iris tenax Toughleaf iris #2 POT PER PLAN 21 Penstemon serrulatus Cascade penstemon #2 POT PER PLAN VINE 12 Akebia quinata Chocolate vine #2 POT PER PLAN PLANTING SCHEDULE - TREES - PIAZZA QTY BOTANICAL NAME COMMON NAME SIZE SPACING COMMENTS 6 Amelanchier laevis ‘Snowcloud’ Snowcloud Serviceberry 3-1/2" CAL PER PLAN 1 Gleditsia triacanthos Honeylocust 3-1/2" CAL PER PLAN 5 Ulmus 'Frontier' Frontier Elm 3-1/2" CAL PER PLAN PLANTING SCHEDULE - SHRUBS, PERENNIALS, AND GRASSES - PIAZZA QTY BOTANICAL NAME COMMON NAME SIZE SPACING COMMENTS DECIDUOUS SHRUB 5 Cornus canadensis Bunchberry #1 POT PER PLAN 7 Cornus sanguinea 'Midwinter Fire' Dogwood 'Midwinter Fire' #5 POT PER PLAN 21 Philadelphus lewesii 'Blizzard' 'Blizzard' Lewis's mock orange #7 POT PER PLAN 10 Spirea 'Little Princess' Little Princess Spirea #5 POT PER PLAN EVERGREEN SHRUB 12 Mahonia aquifolium 'Compacta' Compact Oregon Grape #5 POT PER PLAN FERN 2 Adiantum aleuticum Western Maidenhair fern #2 POT PER PLAN 5 Asplenium trichomanes Maidenhair spleenwort #2 POT PER PLAN 11 Blechnum spicant Deer Fern #2 POT PER PLAN 9 Polypodium glycyrrhiza Licorice fern #2 POT PER PLAN 16 Polypodium scouleri Leathery polypody #2 POT PER PLAN PERENNIAL 187 Achillea millefolium New Vintage White Yarrow #1 POT PER PLAN 16 Allium senescens German Garlic #1 POT PER PLAN 55 Anemone 'Dreaming Swan' Dreaming Swan Anemone #1 POT PER PLAN 29 Aster x frikartii 'Monch' Monch Aster #1 POT PER PLAN 22 Bergenia 'Bressingham White' Bressingham White Bergenia #2 POT PER PLAN 30 Campanula rotundifolia Bluebell #1 POT PER PLAN 3 Dicentra formosa Bleeding Heart #2 POT PER PLAN 100 Dichelostemum congestum Ookow #5 POT PER PLAN 12 Galium odoratum Sweet Woodruff #1 POT PER PLAN 33 Geranium x cantabrigiense 'Biokovo' Cranesbill 'Biokovo' #1 POT PER PLAN 20 Geranium x riversleaianum 'Mavis Simpson' Crane's Bill 'Mavis Simpson' #2 POT PER PLAN 116 Helleborus x ericsmithii 'HGC Monte Criso' Hellebore Snow Rose #2 POT PER PLAN 52 Iris tenax Toughleaf iris #2 POT PER PLAN 34 Penstemon serrulatus Cascade penstemon #2 POT PER PLAN 30 Sidalcea cusickii Cusick's Checkermallow #2 POT PER PLAN 5 Trillium ovatum Western Trillium #2 POT PER PLAN PLANTING SCHEDULE - GROUNDCOVERS - PIAZZA QTY BOTANICAL NAME COMMON NAME SIZE SPACING COMMENTS 491 Fragaria chiloensis Beach Strawberry 4" POT 24" O.C. PRIMARY GROUNDCOVER 174 Mahonia nervosa Cascade Mahonia #2 POT 24" O.C. SECONDARY GROUNDCOVER 435 Polystichum munitum Western Sword Fern #1 POT 18" O.C. 46 Blechnum chilense Chilean Hard Fern #2 POT 24" O.C. SECONDARY GROUNDCOVER 134 Gaultheria shallon Salal #2 POT 24" O.C. PRIMARY GROUNDCOVER 169 Arctostaphylos 'Emerald Carpet' Emerald Carpet Manzanita #2 POT 24" O.C. PRIMARY GROUNDCOVER 58 Ceanothus 'Yankee Point' Yankee Point Ceanothus #2 POT 24" O.C. SECONDARY GROUNDCOVER 101 Asarum caudatum Western wild Ginger 4" POT 18" O.C. PLANTING SCHEDULE - SOD LAWN - PIAZZA AREA BOTANICAL NAME COMMON NAME COMMENTS 3164 SF SOD SOD Turf mix: Turf-Type Perennial Rye Grass, Kentucky Bluegrass, Fine Fescue amorganroth 08/12/2025 CURRENT PLANNING DEVELOPMENT ENGINEERING msippo 08/13/2025 NOTES: 1. AT TREES, ENSURE COMPACTED SOIL INSTALLED TO 6" BELOW DEPTH OF ROOTBALL AND FOR FULL WIDTH OF PIT (2X ROOTBALL Ø) 2. ALL COMPACTED SOIL MUST BE TILLED AT LEAST 6". THIS INCLUDES SOIL THAT HAS EXPERIENCED VEHICULAR LOADING AFTER SOIL HAS BEEN INSTALLED. 3. AT LOCATIONS WHERE EXISTING STUMPS ARE GROUND AND REMOVED, ADD ADDITIONAL TOP SOIL TO MAKE UP ANY DIFFERENCE IN OVERALL SOIL DEPTH. FINISH GRADE MULCH, SEE SPEC SECTION 329113 TWO-WAY SOIL MIX, SEE SPEC SECTION 329113 BLEND 6" OF SOIL MIX WITH MINIMUM 6" EXISTING NATIVE SOIL, SEE SPEC SECTION 329113 EXISTING SUBGRADE 6" 2" MI N . 1' - 0 " OVEREXCAVATION, MIN. DEPTH, 14" FROM FINISH GRADE FINISH GRADE SODDED TURF, SEE SPEC SECTION 32 92 23 8 " EXISTING SOIL OR EXISTING SOIL COMPACTED TO 85% MAX DRY DENSITY LAWN TOPSOIL, SEE SPEC SECTION 32 91 20 MULCH, SEE SPECS 3-WAY PLANTING SOIL, SEE SPECS FILTER FABRIC CLEAN WASHED DRAIN ROCK FINISHED GRADE 1X4 HDPE PLASTIC LUMBER BLOCKING BELOW PLANTERS @ 18" O.C. RUN BLOCKING PARALLEL TO THE SHORT DIRECTION OF THE PLANTER. HOLD ENDS OF BLOCKING 2" INBOARD OF FACE OF PLANTER, TYP. ALL SIDES. 2" 2" 2" TYP. 2' - 0 " 2" MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61PLANTING DETAILS CIVIL CONSTRUCTION PERMIT L3.04 07/16/25 38 R-4334383/4" = 1'-0"1 SOIL PREPARATION - PLANTED AREAS ON GRADE 1 1/2" = 1'-0"2 SOIL PREPARATION - AT TURF AREA 3/4" = 1'-0"3 FREESTANDING PLANTER WITH SOIL amorganroth 08/12/2025 CURRENT PLANNING DEVELOPMENT ENGINEERING msippo 08/13/2025 SET PLANT AT NEW FINISH GRADE MULCH, FEATHER TO BASE OF PLANT FINISH GRADE OF MULCH CONTROLLED RELEASE FERTILIZER GRANULES, PLACE PRIOR TO MULCH APPLICATION IMPORT TOPSOIL PER SPECIFICATIONS MOUND CENTER OF PLANTING PIT TO A 6" PEDESTAL FOR DRAINAGE, COMPACT TO SUBGRADE DENSITY CONTAINER PLANTS: SCORE ROOT BALL IN 3 PLACES TO 1/2" DEPTH IF ROOTBOUND IMPORT TOPSOIL PER SPECIFICATIONS PROVIDE WATER SAUCER 2" HIGH AT ON-GRADE CONDITIONS MULCH PER SPECS, HOLD BACK 2" CLEAR FROM STEM CONTROLLED RELEASE FERTILIZER GRANULES. PLACE PRIOR TO MULCH APPLICATION INSTALL 1" ABOVE CONTAINER DEPTH PRUNE TO REMOVE ONLY DEAD OR DAMAGED BRANCHES NOTE: REMOVE UNTREATED BURLAP FROM TOP 1/3 OF ROOTBALL. REMOVE TREATED BURLAP OR WIRE BASKETS COMPLETELY FINISH GRADE OF MULCH ALL SIDES, TYP. 6" MIN. ROOT BALL DIA. 2 TIMES DIA. MIN, WHEN PLANTED IN EXISTING UNDISTURBED SOIL SHRUB PLANTING REPLACES INSTANCE OF PRIMARY GROUNDCOVER. SEE PLANTING PLANS AND PLANT SCHEDULE FOR SPECIES AND SPACING PRIMARY GROUNDCOVER, SEE PLANTING PLANS AND PLANT SCHEDULE FOR SPECIES AND SPACING SECONDARY GROUNDCOVER, SEE PLANTING PLANS AND PLANT SCHEDULE FOR SPECIES AND SPACING 1x SPACING 1x SPACING 1 x S P A C I N G NOTES: 1. DIG PLANTING PITS DOWN AND OUTWARD SO THAT WATER WILL NOT COLLECT DIRECTLY BELOW ROOTBALL 2. SOAK PLANTING PIT PRIOR TO PLANTING 3. UNCOIL TWISTED OR CIRCULATING ROOTS PRIOR TO PLANTING. CUT OFF ANY PERMANENTLY KINKED ROOTS 4. REMOVE ANY AND ALL PLASTIC FROM ROOTBALL PRIOR TO PLANTING BACKFILL AND COMPACT SOILS AS PER SPECIFICATIONS 1.5 X DIA 2X ROOTBALL DIA 3-4" HIGH MULCH SAUCER SET CROWN OF TREE 2" -3" ABOVE LEVEL OF EXISTING GRADE MULCH TYPE AND DEPTH AS PER ARBORIST SPECIFICATIONS. HOLD MULCH 3" CLEAR FROM TRUNK FINISH GRADE OF MULCH REMOVE ALL WRAPPINGS FROM TOP 1/3 OF ROOTBALL. LEAVE WIRE BASKET ON BOTTOM 2/3 OF ROOT BALL SCARIFY SIDES OF TREE PIT TO PREVENT GLAZING MOUNT CENTER OF PLANTING PIT TO A 10" PEDESTAL FOR DRAINAGE; COMPACT TO SUBGRADE DENSITY. 10 " T Y P . STAKING PER SPECS, TYP ±18", TYP. 5' M A X , 4 ' M I N 6" C L E A R M I N , B E L O W L O W E S T B R A N C H AB O V E FI N I S H E D GR A D E FINISHED GRADE TREE STAKES AS PER SPECS LOCATE STAKES +/-18" FROM TRUNK OF TREE ATTACH STAKES WITH DECOMPOSING TREE STRAPS OR APPROVED EQUAL, SEE SPECS. CENTRAL LEADER. DO NOT CUT. DO NOT PRUNE WITHOUT APPROVAL FROM LANDSCAPE ARCHITECT PREVAILING WIND PARALLEL TO STAKING BASE PLANTING AREA DRIFT PLANTING EXTENTS DRIFT SPECIES PLANTED AT SPECIFIED SPACING, BETWEEND BASE SPECIES PLANTS PER PLAN 1x SPACING MAINTAIN SPACING OF GROUNDCOVER PLANTING IN DRIFT AREA P E R P L A N 1 X S P A C I N G PER PLAN 1X SPACING PRIMARY GROUNDCOVER, SEE PLANTING PLANS AND PLANT SCHEDULE FOR SPECIES AND SPACING SECONDARY GROUNDCOVER, SEE PLANTING PLANS AND PLANT SCHEDULE FOR SPECIES AND SPACING 1x SPACING 1x SPACING 1 x S P A C I N G MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61PLANTING DETAILS CIVIL CONSTRUCTION PERMIT L3.05 07/16/25 39 R-433439 3/4" = 1'-0"1 GROUNDCOVER PLANTING 3/4" = 1'-0"2 SHRUB PLANTING 3/4" = 1'-0"5 SHRUB PLANTING DIAGRAM 1 1/2" = 1'-0"4 TREE PLANTING 3/4" = 1'-0"3 DECIDUOUS TREE STAKING - TYP. 1/2" = 1'-0"6 PERENNIAL PLANTING DIAGRAM 3/4" = 1'-0"7 2-SPECIES GROUNDCOVER PLANTING DIAGRAM amorganroth 08/12/2025 CURRENT PLANNING DEVELOPMENT ENGINEERING msippo 08/13/2025 NOTES: 1. AT TREES, ENSURE COMPACTED SOIL INSTALLED TO 6" BELOW DEPTH OF ROOTBALL AND FOR FULL WIDTH OF PIT (2X ROOTBALL Ø) 2. ALL COMPACTED SOIL MUST BE TILLED AT LEAST 6". THIS INCLUDES SOIL THAT HAS EXPERIENCED VEHICULAR LOADING AFTER SOIL HAS BEEN INSTALLED. 3. AT LOCATIONS WHERE EXISTING STUMPS ARE GROUND AND REMOVED, ADD ADDITIONAL TOP SOIL TO MAKE UP ANY DIFFERENCE IN OVERALL SOIL DEPTH. AGGREGATE SUB BASE 4" IMPORT TOPSOIL PER SPECIFICATIONS 3' - 0 " M I N . SOIL CELL, INSTALL PER MANUFACTURER INSTRUCTIONS CONCRETE PAVING WITH THICKENED EDGE AT TREE PIT OPENING. ENSURE PAVEMENT EDGE IS FULLY SUPPORTED BY SOIL CELLS AGGREGATE FLEXIBLE SURFACING 4" NATIVE SUBGRADE MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61PLANTING DETAILS CIVIL CONSTRUCTION PERMIT L3.06 07/16/25 40 R-433440 3/4" = 1'-0"1 SOIL CELLS ON PROPERTY amorganroth 08/12/2025 CURRENT PLANNING DEVELOPMENT ENGINEERING msippo 08/13/2025 U U U U T T SS (RECORD) SS (RECORD)SS (RECORD) SS (RECORD) P P P P P P 2'2'2'2' YD SOLID COVER RIM 36.44 IE 33.8 SE, 8" IRON SS SS GP GP GP GP GP SS SS SS GP GP GP GP GPGP GP GPGPGPGPGPGPGPGPGPGPGPGPGPGPGP GP GP SS GP&LITE GP LO G A N A V E S BU R N E T T A V E S MATCH LINE, SEE SHEET L4.02 HAND-WATER NEW PLANTERS UNTIL HANDOFF TO OWNER DESIGN AND INSTALL NEW SPRINKLER IRRIGATION IN THIS PLANTING AREA. LOCATE SPRINKLERS TO AVOID OVERSPRAY ONTO PAVEMENTS AND ARCHITECTURAL ELEMENTS WHILE PROVIDING HEAD-TO-HEAD COVERAGE OVER ALL NEW PLANTS. FIELD VERIFY EXISTING IRRIGATION CONTROLLER LOCATION WITHIN MARKET BUILDING. EXISTING IRRIGATION PIPING AND SPRINKLERS IN THIS AREA ARE CONSIDERED ABANDONED AND NOT OPERATIONAL EXISTING IRRIGATION WATER METER EXISTING IRRIGATION BACKFLOW PREVENTION ASSEMBLY AND VALVES IRRIGATION NOTES -MARKET 1. THE RENOVATION OF THE EXISTING IRRIGATION ON THIS PLAN IS DESIGN/BUILD BY THE CONTRACTOR. INVESTIGATE LOCATIONS OF EXISTING IRRIGATION EQUIPMENT AND CONFIRM OPERATION IN AREA NOTED FOR RENOVATION BEFORE DEMOLITION OR OTHER SITE PREPARATION ACTIVITIES DISTURB THE EXISTING IRRIGATION. 2. SELECTIVE DEMOLITION AND PROTECTION IS REQUIRED TO PREPARE THE EXISTING SYSTEM FOR RENOVATION. PREPARATION ACTIVITIES INCLUDE, BUT ARE NOT LIMITED TO: CUTTING AND CAPPING OF PIPES; CUTTING, LABELING AND SPLICING OF IRRIGATION CONTROL WIRES, AND MODIFYING WIRING AND PROGRAMMING AT CONTROLLER. THE FINAL RENOVATION OF THE SYSTEM SHALL RESULT IN AN OPERATION IRRIGATION SYSTEM FOR THE PLANTING AREAS NOTED WITHOUT LEAKS AT ABANDONED PIPE LOCATIONS. 3. CONFIRM AVAILABLE WATER PRESSURE AND FLOW, METER SIZE AND WATER SUPPLY SIZE. DESIGN AND INSTALL ONE OR MORE ZONES TO CORRESPOND WITH AVAILABLE PRESSURE, RESULT IN EXCESS PRESSURE LOSS, AND NOT EXCEED 5 FEET PER SECOND FLOW IN THE NEW PIPES. 4. MATCH THE VALVES, PIPING, SPRINKLERS, AND WIRING AS NOTED ON L4.02 AND THE SPECIFICATIONS. INSTALL, TEST AND RECORD NEW LAYOUT ON DRAWINGS IN ACCORDANCE WITH REQUIREMENTS IN 328400 PLANT IRRIGATION. MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61IRRIGATION PLAN - MARKET CIVIL CONSTRUCTION PERMIT L4.01 07/16/25 41 R-433441 1" = 10'-0"1 IRRIGATION PLAN - MARKET 0 5'10' amorganroth 08/12/2025 CURRENT PLANNING DEVELOPMENT ENGINEERING msippo 08/13/2025 WATER UTILITY ABDOUL GAFOUR 08/13/2025 SS (RECORD) SS (RECORD)SS (RECORD) SS (RECORD) SS (RECORD) SS (RECORD) P P YD SOLID COVER RIM 36.44 IE 33.8 SE, 8" IRONSS GP GP GP GP SS IRRIGATION NOTES -PIAZZA 1. IRRIGATION IMPROVEMENTS FOR THE PIAZZA REQUIRE RENOVATION TO AN EXISTING IRRIGATION SYSTEM. CONFIRM THE LOCATION, OPERATIONAL STATUS, AND CONDITIONS OF THE EXISTING IRRIGATION PIPING AND FEATURES NOTED FOR RETENTION AND RECONNECTION. PROVIDE SYSTEM AS-BUILTS OR A SUMMARY PLAN DETAILING THESE CONDITIONS FOR REVIEW AND APPROVAL PRIOR TO BEGINNING RENOVATION. THIS DOCUMENTATION WILL FORM THE BASIS FOR TESTING REQUIREMENTS FOR RENOVATED COMPONENTS. 2. CONFIRM AVAILABLE WATER PRESSURE AND FLOW, METER SIZE AND WATER SUPPLY SIZE AND SUBMIT A REPORT FOR REVIEW PRIOR TO INSTALLING THE IRRIGATION SYSTEM. 3. SELECTIVE DEMOLITION AND PROTECTION ARE REQUIRED TO PREPARE THE EXISTING SYSTEM FOR RENOVATION AND TO ACCOMMODATE THE WORK OF OTHER TRADES. THESE ACTIVITIES INCLUDE, BUT ARE NOT LIMITED TO CUTTING AND CAPPING OF PIPES, CUTTING, LABELING, AND SPLICING IRRIGATION CONTROL WIRES. PROTECTING PLANTING AREAS WHERE IRRIGATION PIPES AND FIXTURES WILL REMAIN IN PLACE DURING CONSTRUCTION. 4. INSTALL, TEST AND RECORD NEW LAYOUT ON DRAWINGS IN ACCORDANCE WITH REQUIREMENTS IN 328400 PLANT IRRIGATION. 5. LOCATE THE SUPPLY END OF EACH IRRIGATION LATERAL AT RENOVATED PLANTING AREAS. CUT AND PREPARE PIPES TO ALLOW CONNECTIONS FOR EXTENDING NEW IRRIGATION INTO THESE AREAS. 6. NEW SPRINKLER AND IRRIGATION SHALL BE INSTALLED DOWNSTREAM OF THE EXISTING AND/OR PROPOSED DCVA S 3RD STREET LO G A N A V E S BU R N E T T A V E S GPM VALVE STATION 9.58 1" 01 GPM VALVE STATION 8.08 1" 02 GPM VALVE STATION 6.0 1" 04 BUBBLERS GPM VALVE STATION 5.78 1" 05 GPM VALVE STATION 5.04 1" 09 GPM VALVE STATION 5 1" 10 BUBBLERS GPM VALVE STATION 8.91 1" 13 GPM VALVE STATION 13.32 1" 11 GPM VALVE STATION 16.09 1" 12 GPM VALVE STATION 16.29 1" 15 GPM VALVE STATION 12.51 1" 16 GPM VALVE STATION 19.84 1" 18 PIPING LOCATION SHOWN IS DIAGRAMMATIC. INSTALL ALL PIPING WITHIN LANDSCAPE AREAS WHERE POSSIBLE. WHERE PIPING MUST RUN UNDER HARDSCAPING, ROUTE AND SLEEVE AS NEEDED. PROVIDE GATE VALVE AND QUICK COUPLER AT TERMINATION OF MAINLINE. PROVIDE ADDITIONAL WIRE TO CONTROLLER FOR FUTURE SYSTEM EXPANSION. EXISTING IRRIGATION AT ZONE A1 SERVICING TREES IS INTENDED TO REMAIN IN PLACE UNDER EXISTING PAVING. FIELD VERIFY LOCATION OF EXISTING IRRIGATION PIPES AND CONNECT TO NEW SYSTEM AS SHOWN. REPLACE VALVE WITH NEW 1" AUTOMATIC CONTROL VALVE AND WIRE TO NEW CONTROLLER. GPM VALVE STATION 2.78 1" 07 DRIP PROVIDE QUICK COUPLER AT TERMINAL END OF ALL MAINLINES, TYP. ATTACH RAIN SENSOR TO LIGHT POLE INSTALL NEW MICROLINE IRRIGATION AT NEW TREE. PROVIDE WATER BAGS AT NEW TREE DURING ESTABLISHMENT PERIOD PROVIDE SUB-SURFACE DRIP LINE PER SOIL CELL MANUFACTURER'S RECOMMENDATION AND DETAILS, TYP. FIND AND LOCATE EXISTING PIPING SERVICING ZONE A5 TO 3RD STREET ROW TREES. CONNECT TO NEW IRRIGATION SYSTEM. REPLACE VALVE WITH NEW 1" AUTOMATIC CONTROL VALVE AND WIRE TO NEW CONTROLLER. ROUTE AND SLEEVE NEW PIPE UNDER NEW PAVEMENT AS NECESSARY TO CONECT TO EXISTING IRRIGATION PIPING TO REMAIN IN PLACE EXISTING MICROLINE IRRIGATION TO BE REMOVED. PROVIDE 6" DECORATIVE METAL ACCESS VAULT AT JUNCTIONS TO EXISTING IRRIGATION LINES. MATCH LINE, SEE SHEET L4.01 RE-USE EXISTING IRRIGATION CONTROLLER REUSE EXISTING FOUNTAIN PLUMBING PATHWAY TO PROVIDE IRRIGATION TO THIS AREA GPM VALVE STATION 2.08 1" 17 GPM VALVE STATION 7.04 1" 08 GPM VALVE STATION 9.24 1" 06 GPM VALVE STATION 9.93 1" 03 GPM VALVE STATION 13.27 1" 14 LIMIT OF WORK PROPERTY LINE DCVA VALVE SEQUENCE # AND CONTROLLER ID VALVE SIZE GALLONS PER MINUTE SPRAY HEAD KEY RAINBIRD XFS SUB-SURFACE DRIPLINE EVENLY SPACED ±14"-18" IN PLANTERS (18" MAX) WITH 0.6GPH EMITTERS @ 12" OC BUBBLER ZONE KIT QUARTER RAIN BIRD 1800-SAM-PRS SPRAYHEADS W/ MPR NOZZLES SYMBOL DESCRIPTION / MPR RADIUS RANGE GPM VALVE STATION 14.0 1" 4 ROTOR IRRIGATION TYPEIRRIGATION POINT OF CONNECTION - RIGHT OF WAY GATE VALVE BACKFLOW PREVENTER MASTER VALVE FLOW SENSOR QUICK COUPLER AUTOMATIC CONTROL VALVE IRRIGATION CONTROLLER IN LOCKING, STAINLESS STEEL CABINET HARD-WIRED RAIN /FREEZE SENSOR (ONE PER CONTROLLER) BUBBLERS (2 PER TREE AS SHOWN) NOTE: PROVIDE 12" POP-UP HEIGHT AT PLANTING AREAS AND 4" POP-UP HEIGHT AT LAWN AREAS. SUB-SURFACE DRIP IRRIGATION PROVIDE DRIP IRRIGATION SYSTEM AT TREE SOIL CELLS WHERE SHOWN ON PLAN. IRRIGATION LEGEND SCH 40 PVC LATERAL, SEE PIPE SIZING CHART SCH 40 PVC MAINLINE, SEE PIPE SIZING CHART SCH 40 PVC SLEEVE (2X LINE SIZE, 4" MIN)THIRD HALF THREE QUARTER FULL 5:3-5 FEET 8:5-8 FEET 10:7-10 FEET 12:9-12 FEET 15:11-15 FEET PIPE SIZING CHART SCH 40 PVC MAINLINE / LATERALS 1-1/2" MAINLINE GAL/MIN PIPE SIZE 0 - 10 3/4" 10 - 16 1" 16 - 26 1-1/4" 26 - 35 1-1/2" DCVA DOUBLE CHECK VALVE ASSEMBLY MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 62 1 CIVIL PERMIT CORRECTIONS 1 9/15/2025 IRRIGATION PLAN - PIAZZA 100% CONSTRUCTION DOCUMENTS L4.02 02/10/2025 42 R-433442 0 5'10' 1" = 10'-0"1 IRRIGATION PLAN - PIAZZA 1 1 1 WATER UTILITY JValdez 09/17/2025 DEVELOPMENT ENGINEERING msippo 10/02/2025 10X PIPE I.D. MIN. CLEARANCE REQUIRED TO FLOW SENSOR 5X PIPE I.D. MIN. CLEARANCE REQUIRED TO FIRST JOINT OR FITTING EXISTING WATER METER, SEE UTILITY DWGS BRASS PIPE FROM CURB STOP VALVE TO DCVA CURB STOP ISOLATION VALVE PRESSURE REDUCING VALVE (USE WHEN PRESSURE AT METER EXCEEDS 80 PSI, TYP) 1" DOUBLE CHECK VALVE ASSEMBLY FOGTITE #2 METER BOX W/ ADJUSTABLE LOCKING METAL LID MASTER CONTROL VALVE FLOW SENSOR 2" PVC MAINLINE TO AUTOMATIC CONTROL VALVES QUICK COUPLING VALVE BRASS PIPE TO MASTER FROM DCVA BRASS PIPE TO MASTER VALVE BUILD UP WITH BOX EXTENSION OR BRICKS FEBCO 850U SERIES DCVA/BACKFLOW ASSEMBLY PRESSURE GAUGES ON BOTH SIDES OF ASSEMBLY TEST-COCKS TO BE UPRIGHT AND EASILY ACCESSIBLE PRESSURE REDUCING VALVE; OPTIONAL WHEN PRESSURE IS BELOW 80 PSI, TYP; (FACTORY SET TO 50 PSI) -USE WHEN PRESSURE AT METER IS GREATER THAN 80 PSI UNLESS OTHERWISE NOTED, TYP ALL BRASS FITTINGS NIPPLES AND UNIONS BRAS S PIPE FLOW FINISH GRADE MANUAL DRAIN VALVES 1' - 0" M I N . MIN 6" DEPTH CLEAN DRAIN ROCK OVER FILTER FABRIC NOTCH OUT SECTION OF BOX AROUND PIPES 1 CUBIC FOOT DRY SUMP LINED WITH FILTER FABRIC AND FILLED WITH 3/8" GRAVEL BACKFILL BRASS TxT UNION, TO LOOSEN OUTWARD AWAY FROM VALVE (BOTH SIDES) CURB STOP ISOLATION VALVE CENTERED WITHIN RISER 10" ROUND BOX (GREEN IN COLOR) W/ BOLT DOWN T LID 8" Ø SCH 40 PVC RISER, LENGTH AS REQUIRED 6" DEPTH GRAVEL BACKFILL (2) PAVING BRICK BRASS PIPE FROM DEDUCT METER FOGTITE #2 METER BOX (CONCRETE WITH LOCKING METAL LID) 18 " M A X - 1 2 " M I N 24 " M A X 10 X PIPE I.D. MIN FROM FITTING TO FLOW SENSOR 5 X PIPE I.D. MIN FROM FLOW SENSOR TO FIRST FITTING SCH 80 FITTINGS / ADAPTORS 3" OF ≤1 -1/2" WASHED ROCK OVER FILTER FABRIC FIRST ELBOW JOINT OR FITTING (SCH 40 PVC BEYOND) NOTE: TEFLON TAPE ON ALL THREADED FITTINGS SUPER SERVICE SEAL SPLICE KIT FLOW SENSOR PE-89 SHIELDED COMMUNICATION CABLE (MAXI WIRE) TO CONTROLLER SCH 80 PVC PIPE VALVE BOXES W/ LOCKING LIDS 3M-DBY WATERTIGHT SPLICE KIT MASTER VALVE SCH 80 PVCBRASS BRASS PIPE & FITTINGS FROM POC 3" SPARE WIRE BRASS UNION (2 PLACES) FLOW 12 " M I N . C O V E R 4" M I N . NOTE: 1. SLEEVES SHALL BE REQUIRED UNDER ALL PAVED AREAS & WALL OR FOOTING PENETRATIONS. 2. SLEEVE ID PIPE SIZE SHALL BE AT LEAST 2 TIMES GREATER THAN THE TOTAL OD SIZES OF INSERTED PIPES. GRAVEL BACK FILL TYPE 2 MINERAL AGGREGATE (1-1/4" MINUS CRUSHED ROCK) FINISH GRADE NEW PAVEMENT SCH 40 PVC SLEEVE WITH MAIN OR LATERAL LINES & CONTROL WIRES IN SEPARATE CONDUIT &/OR SLEEVE, TYP. WIRES IN SEPARATE SCH 80 PVC ELECTRICAL CONDUIT DETECT-A-TAPE (BLUE & RED), 6" BELOW TOP OF TRENCH GRADE OVER EACH PIPE OR CONDUIT, SEE SPEC 6" T Y P SCH 40 PVC LATERAL LINE SCH 40 PVC MAINLINE TRENCH BACKFILL, SEE SPEC 18 " T Y P . 6 " C L E A R UN L E S S O T H E R W I S E N O T E D 24 " T Y P . FINISH GRADE BUNDLE CONTROL WIRES UNDER MAINLINE ON OPPOSITE SIDE FROM SWING JOINTS (WHEN LATERAL AND MAIN SHARE THE SAME TRENCH) NOTE: TAPE CONTROL WIRES TOGETHER BUT DO NOT TAPE BUNDLED WIRES TO MAINLINE MIN. 18" WIDE TRENCH (OR AS REQUIRED TO ALLOW ADEQUATE COMPACTION OF BACKFILL) UN L E S S OT H E R W I S E N O T E D DETECT-A-TAPE (BLUE) ABOVE MAINLINE ONLY, 6" BELOW FINISHED GRADE, SEE SPEC FINISH GRADE 1" QUICK-COUPLING VALVE 10" ROUND PLASTIC VALVE BOX BACKFILL BOX WITH 3/8" WASHED ROCK BRICK (1 OF 2, TYP.) UNIBODY SWING JOINT, SEE SPECS COMPACTED SUBGRADE PVC MAINLINE DO E S N O T A P P L Y T O R O O F 18 " M I N . A T G R A D E O N L Y . LEEMCO QUICK COUPLING STABILIZER NOTCH RISER AS NECESSARY TO FIT CLEANLY OVER TOE NIPPLE 1 CUBIC FOOT DRY SUMP LINED WITH FILTER FABRIC AND FILLED WITH 3/8" GRAVEL BACKFILL SCH 40 PVC MAINLINE RED & WHITE BRASS GATE VALVE,CENTER WITHIN RISER (SIZE EQUAL TO MAINLINE) SCH 80 PVC SxS UNION, TO LOOSEN OUTWARD AWAY FROM VALVE, BOTH SIDES SCH 80 PVC TOE NIPPLE 10" ROUND BOX (GREEN IN COLOR) W/ BOLT DOWN T LID 8" Ø SCH 40 PVC RISER, LENGTH AS REQUIRED 6" DEPTH 3/8" GRAVEL BACKFILL (2) PAVING BRICK AT ALL CORNERS 24 " M I N 36 " M A X FINISH GRADE REMOTE CONTROL VALVE PER LEGEND & SPECS FINISH GRADE SCH 40 MAINLINE SCH 80 PVC TEE, FITTINGS & ADAPTERS SCH 80 PVC UNION (2 PLACES) RED AND WHITE BRASS GATE VALVE SCH 40 PVC LATERAL 12" DEEP MIN. 3M-DBY WATERTIGHT WIRE SPLICES 24 " M I N - 36 " M A X 12 " M A X 6" OF 1-1/2" WASHED ROCK (OR PEA GRAVEL) 24" COILED SPARE WIRE (DIFFERENT COLOR) INSTALL ONE EXTRA COIL PER VALVE BOX CONCRETE PAVING BRICK SUPPORTING VALVE BOX 3" CLEAR NOTE: 1. CUT 'U' SHAPED NOTCHES IN BOTH SIDES OF VALVE BOX THAT ALLOW 2" MIN CLEARANCE FROM TOP OF PIPE TO TOP OF CUT- OUT. 2. USE TEFLON TAPE ON ALL THREADED FITTINGS. 3. ONLY ONE AUTOMATIC VALVE PER VALVE BOX. 4. VALVE BOX TO REST ON CONCRETE PAVER BRICKS, NO PRESSURE TO BE PLACED ON MAINLINE OR LATERAL LINE. ID TAG CONTROL WIRES (BUNDLE UNDER MAINLINE ON OPPOSITE SIDE FROM LATERALS) SPECIFIED VAULT FLUSH WITH FINISHED GRADE HARDSCAPE, WHERE OCCURS. ADJACENT GRADE VARIES, SEE MATERIALS PLAN ROTOR POP- UP SPRINKLER PER PLAN SPECIFIED COMPACTED BACKFILL TURF / FINISH GRADE 2" PVC SCH 40 STREET ELLS (3) PVC SCH 40 TEE OR ELL PVC LATERAL LINE PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) SET IRRIGATION HEAD 1" ABOVE TOP OF MULCH IN LANDSCAPE BED AREAS AND AT FINISH GRADE IN TURF AREAS HARDWIRED RAIN SENSOR, SEE LEGEND FEMALE ADAPTER (SLIP X FIPT) GALVANIZED 90° EL (1 OF 2) 3/4" GALVANIZED PIPE, PAINT TO MATCH ARCHITECTURAL FINISH WIRE TO IRRIGATION CONTROLLER 1" SCH 40 PVC CONDUIT, FITTINGS AND SWEEP ELL FOR POWER SUPPLY FINISHED GRADE IRRIGATION CONTROLLER IN METAL CABINET AND METAL PEDESTAL. INSTALL CONTROLLER, CABINET AND PEDESTAL PER MANUFACTURER'S RECOMMENDATIONS. CONCRETE PAD: MIN 6" THICKNESS POWER SUPPLY WIRE WIRES TO REMOTE VALVES AND RAIN SENSOR COMPACTED SUBGRADE 3" SCH 40 PVC CONDUIT, FITTINGS AND SWEEP ELL FOR STATION WIRES NOTES: 1. ALL WIRES TO BE INSTALLED PER LOCAL ELECTRICAL CODES. 2. FIELD LOCATE WITH RESIDENT ENGINEER PRIOR TO INSTALLATION. COORDINATE LOCATION WITH ARCH AND MECH. MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61IRRIGATION DETAILS CIVIL CONSTRUCTION PERMIT L4.03 07/16/25 43 R-4334431/8" = 1'-0"1 POINT OF CONNECTION ASSEMBLY DIAGRAM 1" = 1'-0"2 PRV/DCVA ASSEMBLY IN #2 METER BOX 1" = 1'-0"3 MASTER VALVE AND FLOW SENSOR 1 1/2" = 1'-0"5 IRRIGATION TRENCH UNDER PAVING 1 1/2" = 1'-0"6 IRRIGATION TRENCH 1/2" = 1'-0"7 QUICK COUPLER 1" = 1'-0"8 GATE VALVE 3/4" = 1'-0"9 AUTOMATIC CONTROL VALVE 3" = 1'-0"10 SWING ARM & HEAD ASSEMBLY 3" = 1'-0"11 HARDWIRED RAIN SENSOR 1/2" = 1'-0"4 EXTERNAL PEDESTAL MOUNTED CONTROLLER amorganroth 08/12/2025 CURRENT PLANNING DEVELOPMENT ENGINEERING msippo 08/13/2025 WATER UTILITY ABDOUL GAFOUR 08/13/2025 FINISH GRADE VALVE BOX WITH COVER ID TAG DRIP IRRIGATION VALVE PVC SCH 40 FEMALE ADAPTER LATERAL PIPE PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) PVC SCH 40 TEE OR ELL MAINLINE PIPE 30" LINEAR LENGTH OF WIRE, COILED1" BALL VALVE PRESSURE REGULATING QUICK CHECK BASKET FILTER WATERPROOF CONNECTION, TYP. NOTE: 1. CUT 'U' SHAPED NOTCHES IN BOTH SIDES OF VALVE BOX THAT ALLOW 2" MIN CLEARANCE FROM TOP OF PIPE TO TOP OF CUT- OUT. 2. USE TEFLON TAPE ON ALL THREADED FITTINGS. 3. ONLY ONE REMOTE CONTROL VALVE PER VALVE BOX. 4. VALVE BOX TO REST ON CONCRETE PAVER BRICKS, NO PRESSURE TO BE PLACED ON MAINLINE OR LATERAL LINE. CONCRETE PAVING BRICK SUPPORTING VALVE BOX 3" MIN DEPTH OF 3/4" WASHED GRAVEL TURF / FINISH GRADE OR SHRUB BED WITH MULCH DRIPLINE TEE FROM PVC HEADER INLINE DRIP EMITTER SUBSURFACE DRIPLINE TIE DOWN STAKE, SEE NOTESNOTES: 1. NO DRIPLINE SHALL BE VISIBLE ON SURFACE. 2. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, FOUR FEET IN LOAM, AND FIVE FEET IN CLAY. DOES NOT APPLY AT EXTENSIVE GREEN ROOF 3. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR ELBOWS, USE TIE-DOWN STAKES ON EACH LEG OF CHANGE OF DIRECTION. 4" - 6" PE R S P E C 2" - 4 " PE R P L A N T E R D E P T H A T R O O F 18 " A T G R A D E O N L Y , FINISH GRADE ELBOW OR TEE DRIPLINE TUBING PER SPEC BLANK DRIPLINE TUBING 3/4" MALE ADAPTER PVC TEE (SXSXT) PVC LATERAL F A A F F F F F F F F A F F A A A A A A A F POLYGON SHAPED "C" SHAPED ODD SHAPED HOURGLASS SHAPEDCURVED SHAPEDCORNER SHAPEDDOGBONE SHAPED SLOPED CONDITION NOTE: 1. DRIPLINE LATERALS SHOULD FOLLOW THE CONTOURS OF THE SLOPE WHENEVER POSSIBLE. 2. INSTALL AIR RELIEF VALVE AT HIGHEST POINT. 3. NORMAL SPACING WITHIN THE TOP 2/3 OF SLOPE, 4. INSTALL DRIPLINE AT 25% GREATER SPACING AT BOTTOM 1/3 OF THE SLOPE. 5. WHEN THE ELEVATION CHANGE IS 10 FT OR MORE, ZONE THE BOTTOM ON SEPARATE VALVE. FLUSH CAP AIR RELIEF VALVE, INSTALL AT HIGH POINT OF SYSTEM. PVC MANIFOLD LINE WITH PVC TEE. LANDSCAPE DRIPLINE TUBING. WATER SOURCE: DRIP VAVLE OR LATERAL FROM VALVE. PVC SCH 40 TEE OR ELL. PVC MANIFOLD LINE. EASY FIT COMPRESSION ADAPTER. EASY FIT COMPRESSION COUPLING LANDSCAPE DRIPLINE TUBING. CENTER FEED EXAMPLEEND FEED EXAMPLE PVC MAINLINE DRIP VALVE / FILTER / REGULATOR TYPICAL OFFSET 2" FROM HARDSCAPE, 4" FROM PLANTED AREA. PVC HEADER MANIFOLD TYPICAL COMPRESSION FIITING DRIPLINE SPACING AS NOTED. EMITTERS OFFSET FOR TRIANGULAR SPACING. AIR RELIEF VALVE AT HIGH POINT. TYPICAL DRIP LINE WITH EMITTER SPACING AS NOTED. TIE DOWN STAKE AT ALL TEES AND ELLS. LINE FLUSHING VALVE AT LOW END, AS NOTED. PVC LATERAL PIPE TYPICAL FPT ADAPTER AND COMPRESSION COUPLER. MA X I M U M L E N G T H O F S I N G L E LA T E R A L , S E E I R R I G A T I O N N O T E S MA X I M U M L E N G T H O F S I N G L E L A T E R A L , SE E I R R I G A T I O N N O T E S TYPICAL OFFSET 2" FROM HARDSCAPE, 4" FROM PLANED AREA. DRIPLINE TUBING DRIP ZONE KIT: REMOTE CONTROL VALVE WITH FILTER AND PRV FLUSH VALVE PLUMBED TO PVC OR POLY SUPPLY HEADER ISLAND PERIMETER F EXHAUST HEADER A AIR RELIEF VALVE AT HIGH POINT, TYP. A F A F PERIMETER LATERALS 2" TO 4" FROM EDGE, TYP. SEE SPEC FOR ROW SPACING OPOPOP DRIPLINE OPERATION INDICATOR, TYP NOTES: 1.SEE COB STD. DWGS PK-IM-07F AND PK-IM-07G FOR SOIL CELLS. 2.SEE COB STD. DWG. PK-IM-07I FOR IRRIGATION LAYOUT FOR TREE SOIL CELLS WITH TREE PLANTERS AND PLANTER STRIP. 3.SEE MANUFACTURER'S GUIDELINES FOR MAXIMUM LENGTH OF LATERALS. 4.ADJUST IRRIGATION FOR PROPOSED SOIL CELL LAYOUT. NETAFIM TLCV-6-12, CENTERED WITHIN AND BETWEEN SOIL CELLS TYP. VALVE BOX PER PROJECT PLANS ROW TREE PLANTING PER COB STD. DWG. PK-IM-07B SCHEDULE 40 SUPPLY & EXHAUST HEADERS LOCATED IN TREE PIT OR PLANTER STRIP PER COB STD. DWG. PK- IM-07I AND ISOMETRIC THIS PAGE, TYP. MAINLINE PER PROJECT PLANS CEMENT CONCRETE SIDEWALK AND BASE COURSE PER COB STD. DWG. SW-110-1 AND PER PROJECT PLANS SOIL CELL SYSTEM PER MANUFACTURER'S SPECIFICATIONS, TYP. NETAFIM TLCV-6-12 CENTERED WITHIN AND BETWEEN SOIL CELLS AND SPACED FOR EVEN WATER DISTRIBUTION, TYP. ISOMETRIC VIEW SCHEDULE 40 SUPPLY HEADER LOCATED IN TREE PLANTER OR PLANTER STRIP, TYP. BLUE 14 AWG TRACER/ PULL WIRE, TYP. SCHEDULE 40 EXHAUST HEADER LOCATED IN TREE PLANTER OR PLANTER STRIP, TYP. AIR RELIEF VALVE IN VALVE BOX, TYP. MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61IRRIGATION DETAILS CIVIL CONSTRUCTION PERMIT L4.04 07/16/25 44 R-4334441/2" = 1'-0"1 DRIP IRRIGATION VALVE 1" = 1'-0"2 SUB-SURFACE DRIPLINE BURIAL 3/4" = 1'-0"3 DRIPLINE START CONNECTION 1" = 1'-0"4 TYPICAL DRIP LINE LAYOUT REQUIREMENTS 1/2" = 1'-0"5 DRIPLINE ISLAND LAYOUT 1/2" = 1'-0"6 DRIP IRRIGATION AT TREE SOIL CELLS amorganroth 08/12/2025 CURRENT PLANNING DEVELOPMENT ENGINEERING msippo 08/13/2025 WATER UTILITY ABDOUL GAFOUR 08/13/2025 SCORE JOINT (NO TOOL MARKS), WIDTH, DEPTH, AND RADIUS TO BE DETERMINED BY PRE-CONSTRUCTION MEETING BETWEEN CONTACTOR, LANDSCAPE ARCHITECT, STREET USE INSPECTOR, AND BY APPROVED PAVING MOCK-UP 1/2" EXPANSION JOINT (NO TOOL MARKS). HOLD EXPANSION JOINT FILL MATERIAL 1/4" BELOW FINISH GRADE NOTES: 1. SEE LAYOUT PLANS FOR SIDEWALK JOINTING. 2. PROVIDE EXPANSION JOINTS AT EDGE OF PAVING, AND OTHER VERTICAL ELEMENTS. FLUSH SCORE JOINT EXPANSION JOINT NOTE: 1. TYPICAL OF (5) LOCATIONS WITH (5) HEADS APIECE: (3) OLIVIO GRANDE, (2) OLIVIO GOBO PROJECTORS 2. INTEGRAL DUPLEX POWER RECEPTACLE INTALLED IN EACH POLE. MOUNT POWER RECEPTACLE 9' ABOVE BASE OF POLE WITH FLUSH ACCESS DOOR AND TAMPER- RESISTANT HARDWARE. 3. SEE STRUCTURAL FOR FOOTINGS NOTE: TYPICAL OF (8) FIXTURES SUSPENDED OVER LOGAN NOTE: 1. SEE STRUCTURAL FOR FOOTINGS AND POLE DESIGN 1/2" RADIUS, TYP. CIP CONCRETE PLANTER CURB, SEE CIVIL. SLOPE TO DRAIN TOWARDS PLANTING AREAS, TYP. PLANTING AREA WITH MULCH LAWN 2 L3.041 L3.04 1% 6"1/ 2 " SIDEWALK. 4"X6" DOUGLAS FIR SLATS, EASE ALL VISIBLE EDGES POWDERCOATED STEEL SKIRT POWDERCOATED STEEL FRAME HDPE LEVELING FEET FINISHED GRADE 1/ 2 " M A X 1' - 1 " 1/4" MAX R 1/2" 4"X6" DOUGLAS FIR SLATS, EASE ALL VISIBLE EDGES POWDERCOATED STEEL SKIRT POWDERCOATED STEEL FRAME HDPE LEVELING FEET FINISHED GRADE 1' - 6 " R 1/2" 75.0° 1/ 2 " M A X 4"X6" DOUGLAS FIR SLATS, EASE ALL VISIBLE EDGES POWDERCOATED STEEL SKIRT POWDERCOATED STEEL FRAME HDPE LEVELING FEET FINISHED GRADE 1' - 6 " R 1/2" 75.0° 1/ 2 " M A X 1' - 6"POWDERCOATED STEEL BACKREST 1' - 6 " R 1/2" 4"X6" DOUGLAS FIR SLATS, EASE ALL VISIBLE EDGES 1 0 5 .0 ° MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61MATERIALS DETAILS CIVIL CONSTRUCTION PERMIT L5.01 07/16/25 45 R-4334453/4" = 1'-0"1 CIP CONCRETE, TOOLED SCORING AND EXPANSION JOINT 3" = 1'-0"7 MAST LIGHTS AND POLE - SELUX OLIVIO 3" = 1'-0"8 CATENARY LIGHTS N.T.S. N.T.S. 1" = 1'-0"2 CIP CONCRETE FLUSH PLANTER CURB 1/4" = 1'-0"6 REMOVABLE BOLLARD N.T.S. 1 1/2" = 1'-0"3 TYPE 1 WOOD-TOPPED SEATING STRUCTURE 1 1/2" = 1'-0"5 TYPE 2B WOOD-TOPPED SEATING STRUCTURE 1 1/2" = 1'-0"4 TYPE 2A WOOD-TOPPED SEATING STRUCTURE DEVELOPMENT ENGINEERING msippo 08/13/2025 NOTES: 1. STUMP QUANTITY: 3 2. STUMP SPECIES: WESTERN RED CEDAR 3. STUMP SIZE: MIN. 5' Ø ROOT PLATE, MEASURED FROM ROOTS THAT ARE AT LEAST 2" Ø THICK. 5' TALL ABOVE EXSTING CONCRETE PLINTH 4. STUMPS TO BE FREE OF DIRT 5. STUMP SELECTION TO BE REVIEWED BY LANDSCAPE ARCHITECT. 6. STUMP PLACEMENT TO BE FIELD-REVIEWED BY LANDSCAPE ARCHITECT 1/2" STAINLESS STEEL EYE BOLT ANCHORED INTO STUMP STAINLESS STEEL CABLE WITH TURNBUCKLE 4x4 POST @ 36" LONG PRESSURE TREATED LUMBER DEADMAN GRAVEL SETTING BED STUMPS, ORIENT WITH ROOTS POINTING UP PLANTING SOIL GRAVEL DRAINAGE COURSE EXISTING CONCRETE PLINTH SECTION PLAN 6" 4" 1' - 0 " (3) 12" DIAMATER SUMP HOLES, EXTENDING 12" BELOW THE BOTTOM OF CONCRETE AND FILLED WITH DRAIN ROCK 1' - 0" 5' MIN 2" MIN. 5' M I N . PAVEMENT EDGE CONDITION VARIES, REFER TO PLAN CRUSHED STONE POROUS FLEXIBLE PAVER PER MANUFACTURER 2" DEPTH MULCH CLEARANCE TO EDGE OF ROOTBALL NOTE: MICROLINE DRIP IRRIGATION TO BE INSTALLED BELOW FLEXIBLE SURFACING SOIL CELL PLANTING SOIL EXISTING TREE TO REMAIN EXISTING PAVEMENT, REFER TO PLAN CRUSHED STONE POROUS FLEXIBLE PAVING PER MANUFACTURER 2" DEPTH MULCH 3" CONCRETE INFILL. MEET BOTTOM OF EXISTING CHAMFER AT ALL LOCATIONS EXCEPT RUNNEL, SLOPE TO DRAIN AT 1-1.5% THROUGH EXISTING STONE RUNNEL EXISTING FOUNTAIN PLINTH CHAMFER LEADING EDGE OF NEW CONCRETE MA X L W I C E N S E D LANDSC A P E ASH A R C HITECT IN GT O N O F T E TA S PE978 O . N 7 10 8/ 20/ 26 . T T H E W M.POR T E O U S RENTON MARKET & PIAZZA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR SURVEYED:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. CITY OF RENTONDATUM PER PLAN PR 2 4 - 0 0 0 0 8 2 L U A 2 4 - 0 0 0 3 6 4 C 2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 61MATERIALS DETAILS CIVIL CONSTRUCTION PERMIT L5.02 07/16/25 46 R-433446 1/4" = 1'-0"1 NEW CIP CONCRETE AT FOUNTAIN - PLAN 1/4" = 1'-0"4 STUMPERY 1" = 1'-0"3 POROUS FLEXIBLE SURFACING AT NEW TREE 1" = 1'-0"5 POROUS FLEXIBLE SURFACING AT EXISTING TREE 1" = 1'-0"2 NEW CIP CONCRETE AT FOUNTAIN - SECTION DEVELOPMENT ENGINEERING msippo 08/13/2025 R-433446 PR I N T E D : FI L E : IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: SHEET: PAGE: OF: Planning/Building/Public Works Dept. CITY OF RENTON DATUM SURVEYED: DESIGNED: DRAWN: CHECKED: APPROVED: SCALE:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLYAPPRDATEBYREVISIONNO. 4/ 4 / 2 0 2 5 1 1 : 4 2 : 2 0 A M C : \ R e v i t M o d e l s \ 2 0 2 3 \ 2 2 3 3 - R e n t o n P a v i l i o n - S T R U C - R 2 0 2 3 _ p e t e r . z e r k e l . r v t S0.00 STRUCTURAL NOTES AND DRAWING LIST 47248 AMI E E . SULLIV A N S T RUCTURAL E N G I N EERP R O F ESSIONA L E N G I NEER STAT E O F WASHING T O N 47 61 07/16/25 STRUCTURAL NOTES ALL DESIGN AND CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE (IBC), 2021 EDITION, AS AMENDED BY THE CITY OF RENTON. ALTERATIONS TO THE EXISTING BUILDING ARE IN ACCORDANCE WITH THE INTERNATIONAL EXISTING BUILDING CODE (IEBC) AND THE PRESCRIPTIVE COMPLIANCE METHOD. DESIGN LOADS LIVE LOADS IN ADDITION TO THE DEAD LOADS, THE FOLLOWING FLOOR LIVE LOADS WERE USED FOR DESIGN. LIVE LOAD REDUCTION IS PER IBC SECTION 1607.12. REDUCIBLE UNREDUCIBLE CORRIDORS, STAIRS 100PSF X SIDEWALKS, DRIVEWAYS 250PSF X ASSEMBLY AREAS 100PSF X RETAIL STORES 100PSF X DINING ROOM, RESTAURANT 100PSF X LIGHT STORAGE 125PSF X HEAVY STORAGE 250PSF X REFER TO TABLE 1607.1 IN THE IBC FOR RELEVANT CONCENTRATED LIVE LOADS. SOUTH CANOPY STORY DRIFTS RELATIVE LATERAL DISPLACEMENTS OF THE NEW SOUTH CANOPY WITH RESPECT TO THE LEVEL BELOW (STORY DRIFTS) ARE AS FOLLOWS: SEISMIC: DESIGN STORY DRIFT Δ = 2.0 % OF STORY HEIGHT ELASTIC STORY DRIFT = DESIGN STORY DRIFT DIVIDED BY Cd/Ie, WHERE Cd/Ie = 4.4 DEFERRED SUBMITTALS PER IBC SECTION 107.3.4.1, DRAWINGS AND CALCULATIONS FOR THE DESIGN AND FABRICATION OF ITEMS THAT ARE DESIGNED BY OTHERS SHALL BEAR THE SEAL AND SIGNATURE OF THE WASHINGTON STATE REGISTERED PROFESSIONAL ENGINEER WHO IS RESPONSIBLE FOR THE DESIGN AND SHALL BE SUBMITTED TO THE ARCHITECT AND THE BUILDING DEPARTMENT FOR REVIEW PRIOR TO FABRICATION. DEFERRED SUBMITTALS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: FALL ARREST ANCHORS EXTERIOR CLADDING SYSTEMS EQUIPMENT ANCHORAGE SEISMIC DESIGN OF NONSTRUCTURAL COMPONENTS SUSPENDED CEILINGS ALTERNATE ANCHORS (WHEN ALTERNATE ANCHORS ARE PROPOSED) LIGHT POLE TENSILE FABRIC STRUCTURE ROOF SNOW LOAD THE ROOF SNOW LOAD IS DETERMINED USING CHAPTER 7 OF ASCE 7 IN ACCORDANCE WITH IBC SECTION 1608 AND WITH THE FOLLOWING FACTORS: MINIMUM DESIGN LOAD 25 PSF WITHOUT DRIFT Pg = 20 PSF Ce = 1.0 Is = 1.10 Ct = 1.2 Pf = 17 PSF Cs = 1.0 SEISMIC LOADS THE SEISMIC FORCE-RESISTING SYSTEM (SFRS) USED TO RESIST EARTHQUAKE AND WIND LOADS FOR THE NEW SOUTH CANOPY CONSTRUCTION IS COMPRISED OF SPECIAL STEEL MOMENT FRAMES DESIGNED IN ACCORDANCE WITH THE PROVISIONS OF AISC 341 "SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS". EARTHQUAKE DESIGN IS BASED ON THE EQUIVALENT LATERAL FORCE PROCEDURE IN ASCE 7 SECTION 12.8 WITH THE FOLLOWING FACTORS: SITE CLASS F hn = 12 FT RISK CATEGORY III T = 0.2 SECONDS SEISMIC DESIGN CATEGORY D R = 8 Ie = 1.25 Ω = 3 Ss = 1.439 g ρ = 1.3 S1 = 0.491 g Cs = 0.18 SDS = 1.15 g V = CsW = 7 KIPS SD1 = 0.73 g TL = 6 SECONDS THE SEISMIC FORCE-RESISTING SYSTEM IS COMPRISED OF THE STRUCTURAL STEEL MEMBERS AND CONNECTIONS IDENTIFIED IN PLAN. NONSTRUCTURAL COMPONENTS DESIGNED PER ASCE 7 CHAPTER 13 INCLUDE THE FOLLOWING COMPONENTS AND PARAMETERS: KITCHEN MARKET STALLS ap = 1 ap = 2.5 Rp = 2.5 Rp = 2.5 Ω0 = 2 Ω0 = 2 SOIL LOADS ALLOWABLE SOIL-BEARING PRESSURE 2000 PSF DL + LL 2660 PSF DL + LL + SEISMIC/WIND WIND LOADS WIND LOAD IS DETERMINED USING CHAPTERS 26-31 OF ASCE 7 IN ACCORDANCE WITH IBC SECTION 1609 WITH THE FOLLOWING FACTORS: RISK CATEGORY III Kzt = 1.0 EXPOSURE CATEGORY B Ke = 1.0 V = 110 MPH Gcpi = 0.18 Vasd = 84 MPH DESIGN WIND PRESSURES FOR DETERMINING FORCES ON COMPONENTS AND CLADDING SHALL BE DETERMINED USING CHAPTER 30 OF ASCE 7 IN ACCORDANCE WITH IBC SECTION 1609 BY THE WASHINGTON STATE REGISTERED PROFESSIONAL ENGINEER WHO IS RESPONSIBLE FOR THE DESIGN OF SUCH ELEMENTS, UNLESS NOTED OTHERWISE ON THE DRAWINGS. SUBMITTALS SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO ANY FABRICATION OR CONSTRUCTION FOR ALL STRUCTURAL ITEMS, INCLUDING THE FOLLOWING: CONCRETE OR MASONRY REINFORCEMENT, PRECAST OR PRESTRESSED CONCRETE ITEMS, EMBEDDED STEEL ITEMS, STRUCTURAL STEEL, STEEL JOISTS, STEEL DECK, SHEAR STUD LAYOUT, METAL GRATING, GLUED-LAMINATED MEMBERS, CLADDING PANELS AND STAIRS. IF THE SHOP DRAWINGS DIFFER FROM OR ADD TO THE DESIGN OF THE STRUCTURAL DRAWINGS, THEY SHALL BEAR THE SEAL AND SIGNATURE OF THE WASHINGTON STATE REGISTERED PROFESSIONAL ENGINEER WHO IS RESPONSIBLE FOR THE DESIGN. NONSTRUCTURAL COMPONENTS DESIGN, DETAILING AND ANCHORAGE OF ALL NONSTRUCTURAL COMPONENTS SHALL BE IN ACCORDANCE WITH IBC SECTION 1613, ASCE 7 CHAPTER 13, AND THE PROJECT SPECIFICATIONS. NONSTRUCTURAL COMPONENTS DESIGNED BY OTHERS SHALL NOT INDUCE TORSIONAL LOADING INTO SUPPORTING STRUCTURAL MEMBERS WITHOUT ADDITIONAL BRACING OF THOSE MEMBERS TO ELIMINATE TORSIONAL FORCES. TORSIONAL BRACING SHALL BE DESIGNED BY THE NONSTRUCTURAL COMPONENT DESIGNER AND APPROVED BY THE ENGINEER. DESIGN, DETAILING AND CONSTRUCTION OF ALL NONSTRUCTURAL COMPONENTS WHICH ATTACH TO STRUCTURE SHALL ACCOMMODATE CONSTRUCTION TOLERANCES AS ESTABLISHED BY THE STRUCTURAL SPECIFICATIONS. ANY NONSTRUCTURAL COMPONENTS WHICH ATTACH TO MORE THAN ONE LEVEL OF THE STRUCTURE SHALL ALSO ACCOMMODATE THE FOLLOWING RELATIVE MOVEMENTS BETWEEN LEVELS WITHOUT DAMAGE TO THE NONSTRUCTURAL COMPONENTS: GENERAL NOTES CLADDING CLADDING DESIGNED BY OTHERS SHALL BE SUPPORTED AT EACH STORY TO BE CONSISTENT WITH THE DESIGN OF THE BUILDING STRUCTURE. CLADDING DESIGNED BY OTHERS SHALL NOT INDUCE TORSIONAL LOADING INTO SUPPORTING STRUCTURAL MEMBERS WITHOUT ADDITIONAL BRACING OF THOSE MEMBERS TO ELIMINATE TORSIONAL FORCES, UNLESS OTHERWISE APPROVED BY THE ARCHITECT. TORSIONAL BRACING SHALL BE DESIGNED BY THE CLADDING DESIGNER AND APPROVED BY THE ENGINEER. INSPECTION SPECIAL INSPECTION PER IBC CHAPTER 17 SHALL BE PERFORMED BY AN APPROVED TESTING AGENCY AS INDICATED IN THE STATEMENT OF SPECIAL INSPECTIONS AND TESTING. ALL PREPARED SOIL-BEARING SURFACES SHALL BE INSPECTED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT OF REINFORCING STEEL. SOIL COMPACTION SHALL BE SUPERVISED BY AN APPROVED TESTING AGENCY OR GEOTECHNICAL ENGINEER. STRUCTURAL OBSERVATION STRUCTURAL OBSERVATION OF THE SFRS WILL BE PERFORMED BY THE STRUCTURAL ENGINEER OF RECORD IN ACCORDANCE WITH IBC SECTION 1704.6. STRUCTURAL OBSERVATION CONSISTS OF VISUAL OBSERVATION OF THE STRUCTURAL SYSTEMS FOR GENERAL CONFORMANCE TO THE CONSTRUCTION DOCUMENTS AND DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY FOR THE INSPECTIONS REQUIRED BY THE IBC AND AS SHOWN IN THE SPECIAL INSPECTIONS SCHEDULE. CONTRACTOR SHALL PROVIDE A MINIMUM OF 24 HOURS NOTICE BEFORE CONCEALING THE FOLLOWING STRUCTURAL COMPONENTS FROM VIEW: • REINFORCING STEEL FOR THE FIRST PLACEMENT OF THE FOLLOWING ELEMENTS: SFRS FOUNDATIONS • COMPLETION OF FIRST MOMENT FRAME. STRUCTURAL OBSERVATIONS IN ADDITION TO THOSE REQUIRED BY IBC SECTION 1704.6 MAY BE PERFORMED AT THE ENGINEER'S DISCRETION. TIMING OF THESE SHALL BE DISCUSSED AT THE PREINSTALLATION CONFERENCE. SPECIAL CONDITIONS CONTRACTOR SHALL VERIFY ALL LEVELS, DIMENSIONS, AND EXISTING CONDITIONS IN THE FIELD BEFORE PROCEEDING. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR FIELD CHANGES PRIOR TO INSTALLATION OR FABRICATION. IN CASE OF DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND THE DRAWINGS, THE CONTRACTOR SHALL OBTAIN DIRECTION FROM THE ARCHITECT BEFORE PROCEEDING. DIMENSIONS NOTED AS PLUS OR MINUS (±) INDICATE UNVERIFIED DIMENSIONS AND ARE APPROXIMATE. NOTIFY ARCHITECT IMMEDIATELY OF CONFLICTS OR EXCESSIVE VARIATIONS FROM INDICATED DIMENSIONS. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS--DO NOT SCALE DRAWINGS. DIMENSIONS OF EXISTING CONDITIONS ARE BASED ON RECORD DRAWINGS BY MITHUN, DATED 01/28/2003 AND ARE TO BE FIELD-VERIFIED BY THE CONTRACTOR. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY DEMOLITION. CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS, EXISTING CONSTRUCTION AND SOIL EXCAVATIONS, AS REQUIRED, AND IN A MANNER SUITABLE TO THE WORK SEQUENCE. TEMPORARY SHORING AND BRACING SHALL NOT BE REMOVED UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS AND MATERIALS HAVE ACHIEVED DESIGN STRENGTH. NO REINFORCING BARS OR EMBEDS IN EXISTING CONSTRUCTION SHALL BE CUT UNLESS DIRECTED TO BY THE ARCHITECT OR AS SHOWN ON THE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. SOILS SEE THE GEOTECHNICAL REPORT BY ASSOCIATED EARTH SCIENCES, INC DATED OCTOBER 31, 2024, FOR MORE COMPLTE INFORMATION. EARTH WORK MATERIAL, BACKFILL AND COMPACTION SHALL BE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL REPORT. OVEREXCAVATE 2' MINIMUM BELOW FOUNDATIONS AND BACKFILL WITH COMPACTED 2 TO 4 INCH ROCK OR AS REQUIRED BY GEOTECHNICAL SPECIAL INSPECTOR. IF SOILS ARE FOUND TO BE OTHER THAN ASSUMED, NOTIFY THE ARCHITECT FOR POSSIBLE FOUNDATION REDESIGN. FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW FINAL GRADE. EARTHWORK MATERIAL, BACKFILL AND COMPACTION SHALL BE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL SPECIAL INSPECTOR. BACKFILL BEHIND WALLS SHALL NOT BE PLACED BEFORE THE WALLS AND SUPPORTING SLABS ACHIEVE 28 DAY CONCRETE STRENGTH OR THE WALLS ARE TEMPORARILY BRACED. ALL TOPSOIL ORGANICS AND LOOSE SURFACE SOIL SHALL BE REMOVED FROM BENEATH FILL SUPPORTING CONCRETE SLABS OR PAVING.MEMBER SPACING ALL FRAMING MEMBERS SHALL BE EQUALLY SPACED BETWEEN GRID LINES, COLUMNS, AND DIMENSIONED FRAMING UNLESS NOTED OTHERWISE. CONCRETE CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF IBC CHAPTER 19. CONCRETE MIXTURES SHALL CONFORM TO THE MOST STRINGENT REQUIREMENTS FOR EXPOSURE CLASSES SPECIFIED IN THE TABLE ABOVE AND ACI 318 TABLE 19.3.2.1. WATER-REDUCING ADMIXTURES MAY BE INCORPORATED IN CONCRETE MIX DESIGNS, BUT SHALL CONFORM TO ASTM C 494, AND BE USED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. CaCl2 OR OTHER WATER-SOLUBLE CHLORIDE ADMIXTURES SHALL NOT BE USED. CONCRETE MIXTURES CONCRETE MIXTURES SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: CURING IF THE AIR TEMPERATURE WILL EXCEED 75 DEGREES F WITHIN 48 HOURS OF PLACING CONCRETE, A MOIST CURE SHALL BE APPLIED TO THE CONCRETE FOR A PERIOD OF 36 HOURS AFTER FINISHING CONCRETE SURFACES. REFER TO THE PROJECT SPECIFICATIONS FOR CURING REQUIREMENTS. REINFORCING STEEL DEFORMED BARS ASTM A 615, GRADE 60, UNO SPECIAL DUCTILE QUALITY DEFORMED BARS ASTM A 706, GRADE 60 LOW ALLOY, UNO HEADED DEFORMED BARS ASTM A 970, HEAD TYPE HA NONSHRINK GROUT BASE PLATE GROUT SHALL BE NONSHRINK TYPE WITH MINIMUM f'c = 8,000 PSI. ALL OTHER NONSHRINK GROUT SHALL HAVE MINIMUM f'c = 5,000 PSI. REINFORCING STEEL SHALL HAVE PROTECTION AS FOLLOWS, UNLESS NOTED OTHERWISE: USE COVER NONSTRUCTURAL SLAB-ON-GRADE PER DETAILS FOOTING, GRADE BEAM BOTTOM BARS 3" (CAST AGAINST EARTH) TOP BARS 1 1/2" 2" (#6 AND LARGER WHERE EXPOSED TO EARTH OR WEATHER) SIDE BARS 2" WELDING OF REINFORCING, WHERE APPROVED BY THE ARCHITECT, SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES AND PREHEATED IN ACCORDANCE WITH AWS D1.4, REINFORCING STEEL WELDING CODE. WELDERS AND WELDING PROCEDURES SHALL BE QUALIFIED IN ACCORDANCE WITH AWS D1.4. MATERIALS SHALL CONFORM TO THE FOLLOWING: REINFORCING BARS TO BE WELDED ASTM A 706, GRADE 60, LOW ALLOY WELDING ELECTRODES E80XX REINFORCING SHALL BE SUPPORTED AS SPECIFIED BY THE PROJECT SPECIFICATIONS AND THE CRSI MANUAL OF STANDARD PRACTICE. REINFORCING STEEL SHALL BE DETAILED IN ACCORDANCE WITH ACI STANDARD OF PRACTICE AS OUTLINED IN ACI 315, "GUIDE TO PRESENTING REINFORCING STEEL DESIGN DETAILS". LAP ALL REINFORCING BARS AS NOTED ON THE DRAWINGS. WHERE SPLICE LENGTH IS NOT SHOWN, USE TYPE Lb (Lbt FOR TOP BARS) SPLICE PER DEVELOPMENT AND SPLICE LENGTH SCHEDULE. MECHANICAL SPLICES CALLED OUT ON THE PLANS SHALL BE TYPE 1, UNLESS OTHERWISE NOTED. TYPE 1 SPLICES SHALL DEVELOP 125 PERCENT OF THE YIELD CAPACITY OF THE SPLICED BARS IN BOTH TENSION AND COMPRESSION. TYPE 2 SPLICES SHALL DEVELOP THE SPECIFIED TENSILE STRENGTH OF THE SPLICED BARS IN TENSION IN ADDITION TO MEETING TYPE 1 SPLICE REQUIREMENTS. SUBMIT ICC-ES OR IAPMO UES REPORT VALID FOR THE 2021 IBC DEMONSTRATING COMPLIANCE OF COUPLERS WITH THESE REQUIREMENTS. AT THE CONTRACTOR'S OPTION AND WITH THE ARCHITECT'S APPROVAL, HEADED DEFORMED BARS MAY BE USED IN LIEU OF REINFORCING BARS SHOWN WITH STANDARD 90 OR 180 DEGREE HOOKS AND MECHANICAL SPLICES MAY BE USED IN LIEU OF LAP SPLICES. USE OF HEADED DEFORMED BARS IS SUBJECT TO CONFORMANCE WITH ACI 318 SECTION 25.4.4. USE OF MECHANICAL SPLICES IS SUBJECT TO CONFORMANCE WITH ACI 318 SECTION 18.2.7 AND REQUIRES SUBMITTAL OF AN ICC-ES OR IAPMO UES REPORT VALID FOR THE 2021 IBC. ANCHORS POST-INSTALLED ANCHORS PROVIDE POST-INSTALLED ANCHORS AS SPECIFIED IN THESE DRAWINGS. INSTALL ANCHORS IN ACCORDANCE WITH QUALIFYING REPORT OF EVALUATION SERVICE. ANCHOR EMBEDMENT DEPTHS LISTED SHALL BE CONSIDERED EFFECTIVE EMBEDMENT DEPTHS AS DEFINED IN THE ICC-ES OR IAPMO UES EVALUATION REPORTS. PROVIDE ANCHOR LENGTH AND HOLE PER EVALUATION REPORT TO ACCOMMODATE THE EFFECTIVE EMBEDMENT SPECIFIED IN THESE DRAWINGS. SEE DETAIL . MECHANICAL AND ADHESIVE ANCHORS SHALL BE ZINC PLATED CARBON STEEL UNLESS NOTED OTHERWISE. MECHANICAL AND ADHESIVE ANCHORS EXPOSED TO WEATHER SHALL BE STAINLESS STEEL. DO NOT DAMAGE EXISTING REINFORCEMENT. IF LOCATION OF REINFORCEMENT IS UNKNOWN, SCAN FOR EXISTING REINFORCING STEEL PRIOR TO DRILLING. ADHESIVE REINFORCING DOWEL MATERIALS ADHESIVE REINFORCING DOWELS (ARD) ASTM A 615, GRADE 60 THREADED ARD ASTM F 1554, GRADE 36 UNO (CARBON STEEL) ASTM A193 B8M CLASS 1 (STAINLESS) FIELD-MEASURED SLUMP SHALL CONFORM TO THE SUBMITTED CONCRETE MIX DESIGN. TOLERANCE OF SLUMP SHALL CONFORM TO ASTM C 94. ALL CONCRETE SUBJECT TO EXPOSURE CLASSES F1, F2 OR F3 SHALL BE AIR ENTRAINED. AIR-ENTRAINING AGENTS SHALL CONFORM TO ASTM C 260. THE PERCENTAGE OF TOTAL AIR SHALL BE ACCORDING TO ACI 318 TABLE 19.3.3.1 WITH A FIELD TOLERANCE OF ±1.5 PERCENT BY VOLUME. THE PERCENTAGE OF TOTAL AIR SHALL BE MEASURED IN THE FIELD AT THE DISCHARGE FROM THE TRUCK. THE CONTRACTOR SHALL SUBMIT CONCRETE MIX DESIGNS FOR APPROVAL 2 WEEKS PRIOR TO PLACING ANY CONCRETE. THE MIX DESIGN SHALL BE IN CONFORMANCE WITH ACI 318, CHAPTER 19. THE SUBMITTAL SHALL INDICATE WHERE EACH CONCRETE MIX IS TO BE USED ON THE PROJECT, AS WELL AS THE MAXIMUM AGGREGATE SIZE OF EACH MIX. MAXIMUM AGGREGATE SIZE SHALL CONFORM TO THE PROJECT SPECIFICATIONS. WATER/CEMENTITIOUS MATERIALS RATIO SHALL BE MEASURED BY WEIGHT AND SHALL BE BASED ON THE TOTAL CEMENTITIOUS MATERIAL. WATER/CEMENTITIOUS MATERIALS RATIO AND WATER CONTENT SHALL BE DETERMINED BY THE SUPPLIER BASED ON STRENGTH REQUIREMENTS AND SHALL NOT EXCEED THE MAXIMUM WATER/CEMENTITIOUS MATERIAL RATIO AND/OR WATER CONTENT IF SHOWN ABOVE OR IN ACI 318 TABLE 19.3.2.1 FOR THE EXPOSURE CLASSES LISTED. ADHESIVES SHALL NOT BE INSTALLED PRIOR TO THE CONCRETE REACHING AN AGE OF 21 DAYS AS REQUIRED BY ACI 318. ADHESIVE ANCHORS HORIZONTALLY OR UPWARDLY INCLINED TO SUPPORT SUSTAINED TENSION LOADS SHALL BE INSTALLED BY PERSONNEL CERTIFIED BY THE ACI/CRSI ADHESIVE ANCHOR INSTALLER CERTIFICATION PROGRAM, OR EQUIVALENT PROGRAM. USE OF ALTERNATE PRODUCTS, OR OF POST-INSTALLED ANCHORS AT LOCATIONS NOT SHOWN IN THESE DRAWINGS, IS SUBJECT TO THE APPROVAL OF THE ARCHITECT. SUBMIT PROPOSED ANCHORS TO THE ARCHITECT WITH AN ICC-ES OR IAPMO UES REPORT VALID FOR THE 2021 IBC AND DOCUMENTATION SHOWING THAT THE ALTERNATE PRODUCTS PROVIDE EQUIVALENT CAPACITY FOR ALL CONDITIONS IN THIS PROJECT. SUBMITTED ICC-ES AND IAPMO UES REPORTS SHALL DEMONSTRATE THAT THE ANCHORS ARE SUITABLE FOR USE IN CRACKED CONCRETE. WHERE ANCHORS RESIST SEISMIC LOADS OR SUSTAINED TENSION, SUBMITTED ICC-ES AND IAPMO UES REPORTS SHALL DEMONSTRATE THAT THE ANCHORS ARE SUITABLE FOR THE RESISTANCE OF SEISMIC LOADS OR SUSTAINED TENSION (AS APPLICABLE). DOCUMENTATION OF CAPACITY FOR ALTERNATE PRODUCTS MUST BE INCLUDED AS A DEFERRED SUBMITTAL. CONCRETE MIXTURES f'c (PSI) TEST AGE (DAYS) EXPOSURE CLASS USEF S W C 4,000 28 F0 S0 W0 C0 INTERIOR SLAB-ON-GRADE, CURBS AND PADS 4,000 28 F1 S0 W1 C1 FOUNDATIONS, PLINTHS DRAWING LIST S0.00 STRUCTURAL NOTES AND DRAWING LIST S0.01 STRUCTURAL NOTES S0.02 STRUCTURAL ABBREVIATIONS AND SYMBOLS S0.03 STATEMENT OF SPECIAL INSPECTION AND TESTING S0.04 STATEMENT OF SPECIAL INSPECTION AND TESTING S4.05 SITE TYPICAL DETAILS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT T-433447 PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com TR O - 4 1 - 4 3 3 4 DEVELOPMENT ENGINEERING msippo 08/13/2025 R-433447 TE D - 4 0 - 4 3 3 4 PR I N T E D : FI L E : IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: SHEET: PAGE: OF: Planning/Building/Public Works Dept. CITY OF RENTON DATUM SURVEYED: DESIGNED: DRAWN: CHECKED: APPROVED: SCALE:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLYAPPRDATEBYREVISIONNO. 4/ 4 / 2 0 2 5 1 1 : 4 2 : 2 0 A M C : \ R e v i t M o d e l s \ 2 0 2 3 \ 2 2 3 3 - R e n t o n P a v i l i o n - S T R U C - R 2 0 2 3 _ p e t e r . z e r k e l . r v t S0.01 STRUCTURAL NOTES STRUCTURAL NOTES - CONTINUED STRUCTURAL STEEL REFERENCE SPECIFICATIONS STRUCTURAL STEEL AISC 360 "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" HIGH STRENGTH BOLTS RCSC "SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH-STRENGTH BOLTS" WELDING AWS D1.1, TYPICAL AWS D1.3 FOR STEEL DECK AND COLD-FORMED FRAMING AWS D1.8 FOR SUPPLEMENTAL SEISMIC PROVISIONS AWS PREQUALIFIED JOINT DETAILS WELDER CERTIFICATION AMERICAN WELDING SOCIETY (AWS) WASHINGTON ASSOCIATION OF BUILDING OFFICIALS (WABO) STEEL JOISTS AND BRIDGING SJI STANDARD SPECIFICATIONS STEEL DECKING ANSI/SDI C "STANDARD FOR COMPOSITE STEEL FLOOR DECK-SLABS" ANSI/SDI RD "STANDARD FOR STEEL ROOF DECK" AISI S100 WITH S2 "NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS" WITH SUPPLEMENT 2 STEEL MATERIALS WIDE FLANGE SHAPES (W AND WT) ASTM A 992 PLATES (PL), BARS ASTM A 36 TYPICAL, ASTM A 572 GRADE 50 WHERE NOTED ANGLES (L), CHANNELS (C AND MC) ASTM A 36 STRUCTURAL TUBES (HSS) ASTM A 500, GRADE C STEEL PIPE ASTM A 53, GRADE B STRUCTURAL BOLTS ASTM F 3125, GRADE A 325 ANCHOR RODS ASTM F 1554, GRADE 36 UNLESS NOTED OTHERWISE THREADED RODS ASTM A 36, UNLESS NOTED OTHERWISE WELDING ELECTRODES 70 KSI, LOW HYDROGEN, TYPICAL 60 KSI, MINIMUM, STEEL DECK STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION SHALL CONFORM TO THE REQUIREMENTS OF IBC CHAPTER 22. ALL MEMBERS ARE TO BE ERECTED WITH NATURAL MILL CAMBER OR INDUCED CAMBER UP, UNLESS OTHERWISE NOTED ON THE PLANS. SUBSTITUTION OF MEMBER SIZES OR STEEL GRADE WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL BY THE ARCHITECT. A MINIMUM OF TWO BOLTS IS REQUIRED FOR ALL BEAM CONNECTIONS. ALTERNATIVE CONNECTIONS TO THOSE SHOWN ON THESE DRAWINGS WILL REQUIRE PRIOR APPROVAL BY THE ARCHITECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ERECTION AIDS AND JOINT PREPARATIONS THAT INCLUDE, BUT ARE NOT LIMITED TO, ERECTION ANGLES, LIFT HOLES AND OTHER AIDS, WELDING PROCEDURES, REQUIRED ROOT OPENINGS, ROOT FACE DIMENSIONS, GROOVE ANGLES, BACKING BARS, COPES, SURFACE ROUGHNESS VALUES, AND UNEQUAL PARTS. PROTECTED ZONES PORTIONS OF THE SEISMIC FORCE-RESISTING SYSTEM MEMBERS, AS DEFINED IN DETAIL , ARE DEFINED AS PROTECTED ZONES AND ARE SUBJECT TO THE FOLLOWING LIMITATIONS: 1. WITHIN THE PROTECTED ZONES, HOLES, TACK WELDS, ERECTION AIDES, AIR-ARC GOUGING, AND UNSPECIFIED THERMAL CUTTING FROM FABRICATION OR ERECTION OPERATIONS SHALL BE REPAIRED AS REQUIRED BY THE ENGINEER. 2. WELDED HEADED STUD ANCHORS AND DECKING ATTACHMENTS THAT PENETRATE THE BEAM FLANGE SHALL NOT BE PLACED ON BEAM FLANGES WITHIN THE PROTECTED ZONES. ARC SPOT WELDS AS REQUIRED TO SECURE DECKING SHALL BE PERMITTED. 3. WELDED, BOLTED, SCREWED OR SHOT-IN ATTACHMENTS FOR PERIMETER EDGE ANGLES, EXTERIOR FACADES, PARTITIONS, DUCT WORK, PIPING OR OTHER CONSTRUCTION SHALL NOT BE PLACED WITHIN THE PROTECTED ZONES. WELDING ALL WELDING SHALL BE IN CONFORMANCE WITH AISC AND AWS STANDARDS, AND SHALL BE PERFORMED BY AWS-WABO-CERTIFIED WELDERS. ONLY WELDS THAT ARE PREQUALIFIED, AS DEFINED BY AWS, OR QUALIFIED BY TESTING SHALL BE USED. SHOP DRAWINGS SHALL SHOW ALL WELDING WITH AWS A2.4 SYMBOLS. WELDS SHOWN ON THE DRAWINGS ARE MINIMUM SIZES. INCREASE WELD SIZE TO AWS MINIMUM SIZES BASED ON THICKNESS. MINIMUM WELD SIZE SHALL BE 3/16-INCH, UNLESS NOTED OTHERWISE. THE WELDS SHOWN ARE FOR THE FINAL CONNECTIONS. FIELD WELD SYMBOLS ARE SHOWN WHERE FIELD WELDS ARE REQUIRED BY THE STRUCTURAL DESIGN. WHERE FIELD WELD IS NOT INDICATED, THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING IF A WELD SHOULD BE SHOP OR FIELD-WELDED IN ORDER TO FACILITATE THE STRUCTURAL STEEL ERECTION. PROTECTION OF STEEL STRUCTURAL STEEL AND CONNECTIONS, INCLUDING PLATES AND OTHER STEEL ITEMS EMBEDDED IN CONCRETE, WHICH ARE EXPOSED TO WEATHER AND NOT TO BE PAINTED ACCORDING TO THE ARCHITECT, SHALL BE HOT-DIPPED GALVANIZED AFTER FABRICATION IN COMPLIANCE WITH ASTM A 123. ALL FIELD WELDS ON GALVANIZED MATERIAL SHALL BE COATED WITH BRUSH APPLIED ZINC-RICH PAINT COMPLYING WITH ASTM A 780. CLEAN AREAS WHERE GALVANIZING IS DAMAGE OR MISSING AND REPAIR WITH ZINC-RICH PAINT COMPLYING WITH ASTM A 780. ZINC-RICH PAINT SHALL BE A MINIMUM OF 4 MILS OF DRY FILM THICKNESS. STRUCTURAL STEEL AND CONNECTIONS SHALL BE FIREPROOFED WHERE REQUIRED BY THE ARCHITECT. PRIMARY AND SECONDARY STRUCTURE ARE TO BE AS DEFINED BY THE IBC. STRUCTURAL MEMBERS SHALL BE ASSUMED TO BE IN A THERMAL UNRESTRAINED CONDITION FOR THE PURPOSES OF DETERMINING FIREPROOFING THICKNESS. UL DESIGN SHALL BE IN ACCORDANCE WITH LRFD DESIGN METHODOLOGY. WHERE SPRAY-APPLIED CEMENTITIOUS FIREPROOFING IS EXPOSED TO WEATHER, STRUCTURAL STEEL SHALL BE CONSIDERED EXPOSED TO WEATHER, AND SHALL BE PROTECTED ACCORDINGLY. ALL COATINGS ARE TO FOLLOW THE SPECIFICATIONS AND PRODUCT MANUFACTURER'S INSTRUCTIONS. STEEL DECK STEEL DECK SHALL CONFORM TO ASTM A 653. WHERE THE DECK IS LEFT PERMANENTLY EXPOSED, GALVANIZED COATING SHALL CONFORM TO ASTM A 924, G90. IN OTHER AREAS, GALVANIZED COATING SHALL CONFORM TO ASTM A 924, G60. STEEL DECK SHALL CONFORM TO THE FOLLOWING: fy (PSI) USE 40,000 MINIMUM NONCOMPOSITE STEEL ROOF DECK MINIMUM DECK GAUGES ARE SHOWN ON PLANS AND ARE BASED ON 3-SPAN, UNSHORED CONDITIONS. HEAVIER DECK GAUGES MAY BE REQUIRED FOR CONDITIONS OTHER THAN THESE, DEPENDING ON MANUFACTURER'S AND CONTRACTOR'S LAYOUT. DECK SUPPLIER SHALL VERIFY DECK GAUGES AND CAPACITIES BASED ON ACTUAL DECK LAYOUT AND SPAN CONDITIONS INCLUDING A 10 PSF SUPERIMPOSED DEAD LOAD ALLOWANCE FOR THE STEEL ROOF DECK. DEVIATIONS IN DECK GAUGES FROM THOSE SHOWN SHALL BE SUBMITTED TO THE ARCHITECT, ALONG WITH A VALID ICC REPORT FOR APPROVAL PRIOR TO SHOP DETAILING. DECK WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3, "STRUCTURAL WELDING CODE - SHEET STEEL." WELDERS SHALL BE QUALIFIED BY WABO SHEET STEEL WELDER CERTIFICATION PROGRAM. ARC SPOT WELD SIZES NOTED ARE BASED ON THE NOMINAL (VISIBLE) DIAMETER. CONTRACTOR SHALL PROVIDE CLOSURE PLATES, FLASHING, AND ALL MISCELLANEOUS COLD-FORMED FRAMING NECESSARY TO COMPLETE THE WORK. THE MINIMUM BEARING SHALL BE 2 INCHES. NONCOMPOSITE STEEL ROOF DECK STEEL ROOF DECK SHALL BE OF THE SIZE, GAUGE, AND MINIMUM SECTION PROPERTIES SHOWN ON THE PLANS OR AN APPROVED EQUAL. STEEL ROOF DECK FASTENING SHALL BE AS SHOWN ON THE PLANS. THE MINIMUM END LAP SHALL BE 2 INCHES CENTERED OVER SUPPORTS. SUSPENDED CEILINGS, LIGHT FIXTURES, PIPES, DUCTS, MECHANICAL OR ELECTRICAL EQUIPMENT, OR OTHER UTILITIES SHALL NOT BE SUPPORTED BY THE NONCOMPOSITE STEEL ROOF DECK WITHOUT APPROVAL OF THE ENGINEER. HOLES OR COMBINATIONS OF HOLES IN NONCOMPOSITE STEEL ROOF DECK, WHICH CUT TWO WEBS WHICH ARE CLOSER THAN 24 INCHES ON CENTER IN ANY DECK SPAN, MAY REQUIRE DECK REINFORCEMENT AND REQUIRE DIRECTION FROM THE ENGINEER. COLD-FORMED STEEL, LOAD-BEARING REFERENCE STANDARDS • IBC CHAPTER 22, SECTIONS 2210 AND 2211. • AISI S100 WITH S2 "NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD- FORMED STEEL STRUCTURAL MEMBERS" WITH SUPPLEMENT 2 • AISI S240 "NORTH AMERICAN STANDARD FOR COLD-FORMED STEEL STRUCTURAL FRAMING" • AISI S400 "NORTH AMERICAN STANDARD FOR SEISMIC DESIGN OF COLD-FORMED STEEL STRUCTURAL SYSTEMS" SUBMITTALS SUBMIT PRODUCT DATA AND PROOF OF ICC-ES OR IAPMO-UES APPROVAL FOR FRAMING MEMBERS, FASTENERS, AND CONNECTION HARDWARE VALID FOR THE 2021 IBC. ALTERNATE MATERIALS WITH EQUIVALENT SIZE, SHAPE, STRENGTH AND STIFFNESS SHALL BE SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT. FRAMING MEMBERS COLD-FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SIZE, SHAPE, AND GRADE AS INDICATED ON THE DRAWINGS AND IN ACCORDANCE WITH THE STEEL STUD MANUFACTURER'S ASSOCIATION ICC EVALUATION REPORT ESR-3064P. ALL MEMBERS TO HAVE G60 COATING UNLESS NOTED OTHERWISE. ALL EXTERIOR MEMBERS SHALL HAVE G90 COATING. MATERIALS STUDS AND TRACK ASTM A 1003, TYPE H 43 MIL AND THINNER, GRADE 33 54 MIL AND THICKER, GRADE 50 FLOOR JOISTS, ROOF JOISTS AND RIM TRACK TRADEREADY BY CLARKDIETRICH 43 MIL AND THINNER, GRADE 33 54 MIL AND THICKER, GRADE 50 MISCELLANEOUS SHAPES (STRIPS, ASTM A 653, GRADE 50 SHEETS, ANGLES, BRIDGING) SHEET METAL SCREWS ASTM C 1513 FRAMING FASTENERS GRABBER WAFER HEAD SHEAR WALL FASTENERS GRABBER BUGLE HEAD FLOOR AND ROOF DIAPHRAGM FASTENERS GRABBER PAN OR HEX HEAD WELDING ELECTRODES 70 KSI, USE LOW HYDROGEN WHEN WELDING TO STRUCTURAL STEEL SHEET METAL SCREWS FASTENERS SHALL BE SELF-DRILLING AND SHALL EXTEND THROUGH THE CONNECTION WITH A MINIMUM OF 3 EXPOSED THREADS. WELDING WELDING OF COLD-FORMED STEEL SHALL CONFORM TO AWS D1.3 AND SHALL BE PERFORMED BY AWS-WABO CERTIFIED WELDERS. GALVANIZING GALVANIZE ALL MEMBERS IN ACCORDANCE WITH ASTM A 653, G60. FRAMING CONNECTORS CONNECTORS SHALL BE "STRONG-TIE" BY SIMPSON COMPANY AS SPECIFIED IN CATALOG NO. C-CF-2023. PROVIDE THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER UNLESS NOTED OTHERWISE. CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE FASTENERS IN EACH MEMBER. COLD-FORMED STEEL ANCHORS TO CONCRETE AND STEEL WHERE INDICATED ON THE DRAWINGS, PROVIDE ANCHORS PER THE FOLLOWING TABLE. USE OF ALTERNATE PRODUCTS IS SUBJECT TO THE APPROVAL OF THE ARCHITECT. SUBMIT PROPOSED ANCHORS TO THE ARCHITECT WITH AN ICC-ES OR IAPMO UES REPORT VALID FOR THE 2021 IBC. REFERENCE THE ANCHORS SECTION FOR ADDITIONAL REQUIREMENTS. BUNDLED STUDS TWO STUDS IN A BOXED CONFIGURATION, OR STUD GROUPS OF 3 OR MORE MEMBERS, SHALL BE SHOP WELDED WITH 1/8" FLARE GROOVE WELDS x 1/2" LONG, BOTH SIDES AT 12" OC. INSULATION PROVIDE INSULATION IN BOXED OR BUILT-UP FRAMING MEMBERS AS REQUIRED BY THE ARCHITECTURAL DRAWINGS. COLD-FORMED STEEL JOISTS JOISTS ARE ASSUMED TO HAVE FULL LATERAL SUPPORT WITH DECKING ATTACHED TO THE COMPRESSION FLANGE. JOIST ENDS MUST BE BRACED BY RIM TRACK OR BLOCKING. MINIMUM 3 1/2" JOIST BEARING WIDTH AT WALLS. ADD WEB STIFFENER IF BEARING WIDTH IS LESS THAN 3 1/2". RATED SHEATHING WOOD STRUCTURAL PANELS SHALL CONFORM TO THE REQUIREMENTS OF THE LATEST EDITION OF U.S. DEPARTMENT OF COMMERCE (DOC) PS-1 "CONSTRUCTION AND INDUSTRIAL PLYWOOD" OR DOC PS-2 "PERFORMANCE STANDARD FOR WOOD-BASED STRUCTURAL-USE PANELS". EACH PANEL SHALL BEAR THE APA GRADE TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIATION. HARD LID SHEATHING 15/32" 48/24 C-D INT APA WITH EXTERIOR GLUE (CDX) SHEAR WALL SHEATHING 15/32" 32/16 STRUCT 1, EXPOSURE 1 UNO WELDING OF THE SEISMIC FORCE-RESISTING SYSTEM SHALL BE EXECUTED IN ACCORDANCE WITH THE PROVISIONS OF AWS D1.8 "STRUCTURAL WELDING CODE - SEISMIC SUPPLEMENT". WELDS ASSOCIATED WITH THE SEISMIC FORCE-RESISTING SYSTEM ARE IDENTIFIED WITHIN THESE DRAWINGS AS FOLLOWS: NOTE WITHIN WELD TAIL D1.8 INDICATES WELDS SUBJECT TO REQUIREMENTS OF D1.8 D1.8-DCW INDICATES DEMAND CRITICAL WELDS SUBJECT TO ADDITIONAL SPECIFIC REQUIREMENTS WITHIN D1.8 STUD PUNCHOUTS STUD PUNCHOUTS SHALL BE SPACED 24" OC AT MINIMUM. THE FIRST PUNCHOUT SHALL BE A MINIMUM OF 10" AWAY FROM THE ENDS OF EACH STUD. PERMANENT WALL BRIDGING WALL BRIDGING AND BRIDGING ANCHORAGE SHOWN IN THESE DRAWINGS SHALL BE CONSIDERED AS PERMANENT. THIS BRIDGING MUST BE IN PLACE PRIOR TO APPLYING AXIAL LOAD TO STUDS. ERECTION 1. EACH JOIST, RAFTER, ROOF TRUSS, AND WALL STUD SHALL BE IN VERTICAL ALIGNMENT OVER THE ENTIRE BUILDING HEIGHT. 2. STUDS SHALL BE SEATED INTO THE TOP AND BOTTOM TRACKS WITH LESS THAN 1/16" GAP BETWEEN THE END OF THE STUD AND THE WEB OF THE TRACK. 3. HANDLING AND LIFTING OF PREFABRICATED PANELS SHALL NOT CAUSE PERMANENT DISTORTION TO ANY MEMBER. FIELD CUTS AND NOTCHES FIELD CUTS OR NOTCHES OF ANY KIND ARE NOT PERMITTED IN LOAD-BEARING COLD- FORMED STEEL MEMBERS. IF A FIELD CUT IS REQUIRED, THE CONTRACTOR SHALL RECEIVE DIRECTION FROM THE ARCHITECT PRIOR TO CUTTING. ALL HARD LID SHEATHING AND SUBFLOORING SHALL BE INSTALLED FACE GRAIN PERPENDICULAR TO SUPPORTS OR AS INDICATED ON THE DRAWINGS. ROOF AND SUBFLOORING SHEATHING SHALL BE UNBLOCKED OR AS INDICATED ON DRAWINGS. INSTALL WITH 1/8" GAP BETWEEN PANELS. SHEAR WALL SHEATHING SHALL BE BLOCKED AT ALL PANEL EDGES AS INDICATED IN THE SHEAR WALL SCHEDULE, UNLESS NOTED OTHERWISE. ALL FASTENERS AND CONNECTORS IN CONTACT WITH PRESERVATIVE-TREATED LUMBER SHALL BE GALVANIZED WITH A MINIMUM COATING OF 1.85 OUNCES/SQUARE FOOT. PRESERVATIVE-TREATED WOOD WOOD SHALL BE PROTECTED FROM DECAY AND TERMITES IN ACCORDANCE WITH IBC 2304.12. PRESERVATIVE-TREATMENTS SHALL CONFORM TO THE APPROPRIATE STANDARDS OF THE AWPA FOR SAWN LUMBER, GLUED-LAMINATED TIMBER, ROUND POLES, PILES, AND MARINE PILES AND SHALL BEAR A TREATMENT IDENTIFICATION MARK BY THE CERTIFYING AGENCY. THE SELECTED PRESERVATIVE-TREATMENT SHALL CONFORM TO THE "BEST MANAGEMENT PRACTICES" OF THE WWPI. ALL LUMBER IN CONTACT WITH CMU, CONCRETE, OR GROUND SURFACES SHALL BE PRESERVATIVE-TREATED. PRESERVATIVE TREATMENT SHALL NOT REDUCE ALLOWABLE DESIGN STRESSES. LUMBER SHALL ALSO BE TREATED TO THE M4-16 (FIELD TREATMENT) STANDARD. SAWN LUMBER SAWN LUMBER SHALL CONFORM TO THE LATEST EDITION OF "GRADING AND DRESSING RULES" BY WCLIB OR "WESTERN LUMBER GRADING RULES" BY WWPA. LUMBER SHALL BE SEASONED DRY WITH A MAXIMUM MOISTURE CONTENT OF **15%** **19%** AND BE THE SPECIES AND GRADE SPECIFIED BELOW. USE GRADE Fb (PSI) (SINGLE USE) PLANKING & PLATES 2" TO 4" THICK, 2" AND WIDER HEM-FIR NO. 2 850 DOUGLAS FIR-LARCH NO. 2 900 JOISTS & RAFTERS 2" TO 4" THICK, 2" AND WIDER HEM-FIR NO. 2 850 DOUGLAS FIR-LARCH NO. 2 900 BEAMS & STRINGERS 5"x5" AND LARGER DOUGLAS FIR-LARCH NO. 1 1,350 WOOD WOOD CONSTRUCTION SHALL CONFORM TO ALL REQUIREMENTS OF IBC CHAPTER 23. WOOD FASTENERS AND CONNECTORS WOOD CONNECTORS SHALL BE SIMPSON STRONG-TIE AS SPECIFIED IN CATALOG NO. C-C-2021, OR APPROVED EQUAL. INSTALL CONNECTORS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS WITH NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE FASTENERS IN EACH MEMBER. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A 307. PROVIDE STANDARD WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. ALL SHIMS SHALL BE SEASONED DRY AND BE THE SAME GRADE (MIN) AS THE MEMBERS CONNECTED. ALL JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH LU SERIES JOIST HANGERS, UNLESS NOTED OTHERWISE. ALL DOUBLE AND TRIPLE-JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH U SERIES HANGERS, UNLESS NOTED OTHERWISE. ALL FRAMING NAILS SHALL HAVE THE SIZE AND MINIMUM LENGTH AS SPECIFIED IN THE FOLLOWING TABLE, UNLESS NOTED OTHERWISE. NAIL TYPE SHALL BE COMMON UNLESS NOTED OTHERWISE. POWER-DRIVEN NAILS AND STAPLES SHALL BE IN ACCORDANCE WITH ICC-ES ESR-1539. NAILING NOT SHOWN SHALL BE AS INDICATED IN IBC TABLE 2304.10.2. POWER-DRIVEN NAILS MAY BE SUBSTITUTED FOR COMMON NAILS AT SPACING AS FOLLOWS. SUBSTITUTIONS FOR NAIL SIZE, SPACING, OR QUANTITY NOT SHOWN REQUIRE APPROVAL. 1/S5.00 WELDS NOTED AS D1.8 SHALL BE MADE WITH FILLER METAL PRODUCING WELDS WITH A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FT-LBF AT 0 DEGREES-F AS DETERMINED BY THE APPLICABLE AWS A5 CLASSIFICATION TEST METHOD. FILLER METAL FOR WELDS NOTED AS D1.8-DCW SHALL ALSO HAVE A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 40 FT-LBF AT 20 DEGREES-F AS DETERMINED BY SECTION A3.4B OF AISC 341-16. CONTRACTOR SHALL SUBMIT TO THE BUILDING OFFICIAL THE WELDING PROCEDURE SPECIFICATIONS VERIFYING THESE REQUIREMENTS. REMOVE FINISHES FROM STEEL PRIOR TO COMPLETING WELDED CONNECTIONS. REPAIR FINISHES AS REQUIRED PER "PROTECTION OF STEEL" SECTION ABOVE AND PER THE SPECIFICATIONS. COLD-FORMED STEEL ANCHORS TO CONC AND STEEL APPLICATION PRODUCT DIAMETER EMBED MIN EDGE DISTANCE MIN SPACING EVALUATION REPORT PAF TO STEEL HILTI X-S16P8TH 0.145" FULL STEEL PENETRATION (3/16" MIN) 1/2" 1" ICC-ES ESR-1752 CONCRETE SCREW ANCHOR SIMPSON TITEN HD 3/8" 2 1/2" 2 3/4" 3" ICC-ES ESR-2713 FRAMING NAILS TYPE MARK TYPE SHANK DIAMETER MINIMUM LENGTH 8d COMMON 0.131" 2 1/2" 10d COMMON 0.148" 3" 16d COMMON 0.162" 3 1/2" 16d-SHORT SHORT 0.131" 3 1/4" ALTERNATE NAILING SCHEDULE FASTENER TYPE SHANK DIAMETER LENGTH SPACING 8d COMMON 0.131" 2 1/2" 16" 12" 8" 6" 4" 3" 2" 16d SHORT 0.131" 3 1/4" 16" 12" 8" 6" 4" 3" 2" 10d COMMON 0.148" 3" 16" 12" 8" 6" 4" 3" 2" 16d SHORT 0.131" 3 1/4" 12" 10" 6" 4" 3" 2 1/2" 1 1/2" 16d COMMON 0.162" 3 1/2" 16" 12" 8" 6" 4" 3" - 16d SHORT 0.131" 3 1/4" 10" 8" 5" 4" 2 1/2" 2" - RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT T-433448 PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 48 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com TR O - 4 1 - 4 3 3 4 07/16/25 61 47248 AMI E E . SULLI V A N S T R UCTURAL E N G I N EERP R O F E SSI ONA L E N G I N EER STAT E O F WASHIN G T O N DEVELOPMENT ENGINEERING msippo 08/13/2025 TE D - 4 0 - 4 3 3 4 R-433448 PR I N T E D : FI L E : IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: SHEET: PAGE: OF: Planning/Building/Public Works Dept. CITY OF RENTON DATUM SURVEYED: DESIGNED: DRAWN: CHECKED: APPROVED: SCALE:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLYAPPRDATEBYREVISIONNO. 4/ 4 / 2 0 2 5 1 1 : 4 2 : 2 0 A M C : \ R e v i t M o d e l s \ 2 0 2 3 \ 2 2 3 3 - R e n t o n P a v i l i o n - S T R U C - R 2 0 2 3 _ p e t e r . z e r k e l . r v t S0.02 STRUCTURAL ABBREVIATIONS AND SYMBOLS T/SLAB LEVEL 01 10CONCRETE COLUMN ABOVE OR PASSING THROUGH THIS LEVEL CONCRETE COLUMN BELOW REINFORCING TYPE STEPPED FOOTING LOW SIDE PARTIAL HEIGHT CONCRETE WALL MASONRY WALLS CONCRETE WALL ABOVE OR PASSING THROUGH LEVEL CONCRETE IN CROSS SECTION EXISTING CONCRETE IN CROSS SECTION CONCRETE SYMBOLS STEEL COLUMN ABOVE OR PASSING THROUGH THIS LEVEL STEEL COLUMN BELOW THIS LEVEL STEEL IN CROSS SECTION 24 x 1 2 B 1 8" Ø A 1 6D 5 6 FH [5 , 3 , 5 ] C 1 " BEAM SIZE NUMBER OF STUDS CAMBER AT MID-SPAN COLUMN BELOW FULL HEIGHT PLATE CONNECTION SPECIAL STUD SPACING FOR GIRDERS NUMBER OF BOLTS IN SPECIAL CONNECTIONS NUMBER OF BOLTS IN CONNECTION IF DIFFERENT FROM TYPICAL SCHEDULE TOP OF STEEL ELEVATION DEVIATION FROM TYPICAL SPECIAL MOMENT RESISTING FRAME CONNECTION MOMENT OR TENSION RESISTING CONNECTION BEAM PENETRATION BOT FLANGE BEAM BRACE SHOP WELDED CANTILEVER W24x55 [20] C 3/4" (-10") W1 8 x 3 5 [ 1 2 ] C 1 " W2 1 x 4 4 W2 4 x 6 2 [ 2 4 ] S F R S MEMBER OF THE SEISMIC FORCE- RESISTING SYSTEM STEEL SYMBOLS BRACED FRAME ABOVE BRACED FRAME BELOW DEMOLISH FRAMING DEMOLISH SLAB DEMOLISH CONCRETE WALL DEMOLISH CONCRETE COLUMN DEMOLISH STEEL COLUMN DEMOLITION SYMBOLS DEMOLISH CMU WALL GRID BUBBLE SURFACE -SLOPE UP SURFACE -STEPPED SURFACE -SLOPE DOWN SURFACE -SLOPE TWO WAYS UNDISTURBED SOIL, COMPACTED SOIL, BACKFILL, OR ANY PREPARED SUBGRADE. SEE SPECIFICATIONS FOR TYPE OF MATERIAL AND PREPARATION METHOD. STANDARD SECTION CUTS NORTH ARROW BUILDING SECTION CUTS ELEVATION OF WALL OR FRAME SPOT ELEVATION:TOP OF PLYWOOD TOP OF CONCRETE TOP OF STEEL TOP OF CONCRETE ELEVATION TOP OF STEEL ELEVATION WORKPOINT DIRECTION OF DOWNWARD SLOPE DIRECTION OF SPAN PLAN NORTH WP REFERENCE ELEVATION. REFER TO PLAN UNLESS NOTED OTHERWISE. EXISTING FRAMING ELEVATION OF LEVEL GENERAL SYMBOLS  ?  ?  ?  ? ____  ?  ? ____ ?  ? ____ 100'-0" 100'-0" 100'-0" S3.1 1 S3.1 1 S3.1 1 S3.1 1 AB ANCHOR BOLT ADD'L ADDITIONAL ADH ADHESIVE ADJ ADJUSTABLE AESS ARCHITECTURALLY EXPOSED STRUCTURAL STEEL AFF ABOVE FINISH FLOOR AGG AGGREGATE ANCH ANCHOR ARCH ARCHITECTURAL ARD ADHESIVE REINFORCING DOWEL B/ BOTTOM OF BLDG BUILDING BLKG BLOCKING BM BEAM BN DIAPHRAGM BOUNDARY NAILING BOT BOTTOM BRB BUCKLING-RESTRAINED BRACE BRBF BUCKLING-RESTRAINED BRACE FRAME BRG BEARING BSMT BASEMENT BTWN BETWEEN BUR BUILT-UP ROOF C CAMBER CAP CAPACITY CC CENTER TO CENTER CDF CONTROLLED DENSITY FILL CFS COLD-FORMED STEEL CIP CAST-IN-PLACE CJ CONSTRUCTION OR CONTROL JOINT CJP COMPLETE JOINT PENETRATION CL CENTERLINE CLG CEILING CLR CLEAR CLT CROSS-LAMINATED TIMBER CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CONTY CONTINUITY COORD COORDINATE CTR CENTER CY CUBIC YARD DB DIVIDER BEAM DBA DEFORMED BAR ANCHOR DBL DOUBLE DCW DEMAND CRITICAL WELD DEMO DEMOLISH DET DETAIL DF DOUGLAS FIR DIA DIAMETER DIAG DIAGONAL DKG DECKING DN DOWN DO DITTO DWF DEFORMED WIRE FABRIC DWG DRAWING DWL DOWEL EA EACH EF EACH FACE EL ELEVATION ELECT ELECTRICAL ELEV ELEVATOR EN PANEL EDGE NAILING EQ EQUAL EQUIP EQUIPMENT ES EACH SIDE EW EACH WAY EX EXISTING EXP EXPANSION EXT EXTERIOR F FAHRENHEIT FD FLOOR DRAIN FDN FOUNDATION FF FINISH FLOOR FIN FINISH FLG FLANGE FLR FLOOR FOB FACE OF BUILDING FS FAR SIDE FT FEET FTG FOOTING GA GAUGE GALV GALVANIZED GB GRADE BEAM GEN GENERAL GL GLUED LAMINATED TIMBER GOVT GOVERNMENT GR GRADE GWB GYPSUM WALL BOARD HF HEM-FIR HGR HANGER HK HOOK HORIZ HORIZONTAL HP HIGH POINT HSS HOLLOW STRUCTURAL SECTION IBC INTERNATIONAL BUILDING CODE ID INSIDE DIAMETER STRUCTURAL ABBREVIATIONS STRUCTURAL DRAWING SYMBOLS IE INVERT ELEVATION IF INSIDE FACE IN INCH INFO INFORMATION INT INTERIOR JST JOIST JT JOINT K KIP (1,000 LBS.) KSF KIPS PER SQUARE FOOT LF LINEAL FOOT LFH LONG FACE HORIZONTAL LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LNGT LONGITUDINAL LP LOW POINT LSL LAMINATED STRAND LUMBER LVL LAMINATED VENEER LUMBER MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MOM MOMENT NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NS NEAR SIDE NS NONSHRINK NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OPNG OPENING OPP OPPOSITE P POST PAF POWER ACTUATED FASTENER PC PIECE PC PILE CAP PEN PENETRATION PJP PARTIAL JOINT PENETRATION PL PROPERTY LINE PL PLATE PLWD PLYWOOD PNL PANEL PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT POST-TENSIONED PT PRESERVATIVE-TREATED PWT PREFABRICATED WOOD TRUSS R RADIUS RD ROOF DRAIN REINF REINFORCING REM REMAIN(DER) REQ'D REQUIRED RND ROUND RO ROUGH OPENING RTN RETURN SC SLIP CRITICAL SCHED SCHEDULE SDCI SEATTLE DEPARTMENT OF CONSTRUCTION AND INSPECTIONS SDQ SPECIAL DUCTILE QUALITY SECT SECTION SFRS SEISMIC FORCE-RESISTING SYSTEM SHT SHEET SHTG SHEATHING SIM SIMILAR SOG SLAB-ON-GRADE SP SPACE SPEC SPECIFICATION SQ SQUARE SST STAINLESS STEEL ST SUSTAINED TENSION ANCHOR STD STANDARD STIFF STIFFENER STIRR STIRRUP STL STEEL STRUCT STRUCTURAL SUPP SUPPORT SYM SYMMETRICAL T&B TOP AND BOTTOM T&G TONGUE AND GROOVE T/ TOP OF TB TABLE THK THICK(NESS) THRU THROUGH TRANS TRANSVERSE TYP TYPICAL UNO UNLESS NOTED OTHERWISE UT ULTRASONIC TESTING VERT VERTICAL VIF VERIFY IN FIELD W W-SHAPE W/ WITH W/O WITHOUT WD WOOD WHS WELDED HEADED STUD WL WATER LINE WP WORK POINT WSBC WASHINGTON STATE BUILDING CODE RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT T-433449 PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 49 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com TR O - 4 1 - 4 3 3 4 07/16/25 61 47248 AMI E E . SULLI V A N S T R UCTURAL E N G I N EERP R O F E SSI ONA L E N G I N EER STAT E O F WASHIN G T O N DEVELOPMENT ENGINEERING msippo 08/13/2025 R-433449 TE D - 4 0 - 4 3 3 4 PR I N T E D : FI L E : IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: SHEET: PAGE: OF: Planning/Building/Public Works Dept. CITY OF RENTON DATUM SURVEYED: DESIGNED: DRAWN: CHECKED: APPROVED: SCALE:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLYAPPRDATEBYREVISIONNO. 4/ 4 / 2 0 2 5 1 1 : 4 2 : 2 0 A M C : \ R e v i t M o d e l s \ 2 0 2 3 \ 2 2 3 3 - R e n t o n P a v i l i o n - S T R U C - R 2 0 2 3 _ p e t e r . z e r k e l . r v t S0.03 STATEMENT OF SPECIAL INSPECTION AND TESTING STATEMENT OF SPECIAL INSPECTIONS AND TESTING 1. SPECIAL INSPECTIONS SHALL CONFORM TO CHAPTER 17 OF THE INTERNATIONAL BUILDING CODE (IBC) AND THE REFERENCE CODES AND STANDARDS LISTED IN NOTE 2. REFER TO TABLES 1 AND 2 FOR SPECIAL INSPECTION AND TABLES 3 AND 4 FOR TESTING REQUIREMENTS. 2. REFERENCE CODES AND STANDARDS ARE AS FOLLOWS: IBC 2021 ACI 318-19 AWC SDPWS 2021 AWS CURRENT EDITION ASTM CURRENT EDITION AISC 360-16 AISC 341-116 RCSC 2014 SDI QA/QC-2017 3. SPECIAL INSPECTIONS AND ASSOCIATED TESTING SHALL BE PERFORMED BY AN APPROVED QUALIFIED TESTING AND INSPECTING AGENCY MEETING THE REQUIREMENTS OF ASTM E 329 (MATERIALS), ASTM D 3740 (SOILS), ASTM C 1077 (CONCRETE), AND ASTM E 543 (NON-DESTRUCTIVE). THE TESTING AND INSPECTING AGENCY SHALL FURNISH TO THE ARCHITECT A COPY OF THEIR SCOPE OF ACCREDITATION. SPECIAL INSPECTORS SHALL BE CERTIFIED BY THE BUILDING OFFICIAL. WELDING INSPECTORS SHALL BE QUALIFIED PER SECTION 6.1.4.1.1 OF AWS D1.1. AND WABO 4. THE SPECIAL INSPECTOR SHALL OBSERVE THE INDICATED WORK FOR COMPLIANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTOR FOR CORRECTION AND NOTED IN THE INSPECTION REPORTS. ISSUES REQUIRING IMMEDIATE CORRECTIVE ACTIONS OR ENGINEERING INPUT ARE TO BE BROUGHT TO THE ENGINEER'S ATTENTION IMMEDIATELY UPON DISCOVERY. 5. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS FOR EACH INSPECTION TO THE BUILDING OFFICIAL, ARCHITECT, CONTRACTOR, AND OWNER. THE TESTING AND INSPECTING AGENCY SHALL SUBMIT A FINAL REPORT STATING THAT THE WORK REQUIRING SPECIAL INSPECTION WAS INSPECTED AND IS IN CONFORMANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS AND THAT ALL DISCREPANCIES NOTED IN THE INSPECTION REPORTS HAVE BEEN CORRECTED. 6. CONTRACTOR TO FURNISH WELDING PROCEDURE SPECIFICATIONS (WPSs) AND PROCEDURE QUALIFCATION RECORDS (PQRs) IN ACCORDANCE WITH AWS D1.1 "STRUCTURAL WELDING CODE - STEEL" FOR EACH WELDED JOINT TO THE BUILDING OFFICIAL, ARCHITECT, CONTRACTOR, AND OWNER. 7. CONTINUOUS SPECIAL INSPECTION: SPECIAL INSPECTION BY THE SPECIAL INSPECTOR WHO IS PRESENT WHEN AND WHERE THE WORK TO BE INSPECTED IS BEING PERFORMED. PERIODIC SPECIAL INSPECTION: SPECIAL INSPECTION BY THE SPECIAL INSPECTOR WHO IS INTERMITTENTLY PRESENT WHERE THE WORK TO BE INSPECTED HAS BEEN OR IS BEING PERFORMED. 8. WHERE PERIODIC INSPECTION IS ALLOWED IN ACCORDANCE WITH THE ANCHOR ICC/IAPMO EVALUATION REPORT, INSPECTIONS SHALL BE AS FOLLOWS: - FOR ALL ANCHORS, PRIOR TO CONCEALMENT, VERIFY: ANCHOR TYPE, ANCHOR DIMENSIONS, ANCHOR SPACING AND EDGE DISTANCE. - FOR EACH ANCHOR TYPE AND SIZE, INSPECTOR SHALL BE ONSITE TO CONTINUOUSLY INSPECT A MINIMUM OF THE FIRST 10 ANCHORS INSTALLED BY EACH INSTALLER FOR CONFORMANCE WITH ICC/IAPMO EVALUATION REPORT. PROVIDED ALL ANCHORS ARE INSTALLED CORRECTLY PER MANUFACTURER'S INSTRUCTIONS, PROVIDE PERIODIC INSPECTION ON A MINIMUM OF 10% OF THE NEXT 1000 ANCHORS BY EACH INSTALLER AND A MINIMUM OF 5% OF THE REMAINING ANCHORS BY EACH INSTALLER. INSPECTIONS SHALL OCCUR A MINIMUM OF ONCE PER WEEK AT A RANDOM TIME WHILE ANCHOR INSTALLATION IS ONGOING. ANY NON-COMPLIANCE ISSUES SHALL RESET THE INSPECTION REQUIREMENTS TO TEN (10) CONTINUOUS INSPECTIONS. NON-COMPLIANT ANCHORS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD FOR REVIEW AND SHALL BE BROUGHT INTO COMPLIANCE BY EITHER TESTING OR RE-INSTALLATION. - INSPECTION REPORTS SHALL IDENTIFY NAMES OF INSTALLERS. - SPECIAL INSPECTOR SHALL PROVIDE DOCUMENTATION AT THE END OF ANCHOR INSTALLATIONS STATING THAT THE MINIMUM NUMBER OF ANCHORS WERE INSPECTED. 9. OBSERVE: OBSERVE THESE ITEMS ON A RANDOM BASIS. OPERATIONS NEED NOT BE DELAYED PENDING THESE INSPECTIONS. PERFORM: PERFORM THESE TASKS FOR EACH ELEMENT. 10. INDICATED CONCRETE TESTING MEETS MINIMUM REQUIREMENTS FOR STRUCTURAL TESTING TO BE PROVIDED BY THE APPROVED QUALIFIED TESTING AND INSPECTING AGENCY. ADDITIONAL TESTING FOR CONSTRUCTION CONSIDERATIONS ARE NOT INDICATED AND SHALL BE DETERMINED BY THE CONTRACTOR AND PROVIDED AT CONTRACTOR'S EXPENSE. 11. SEE S0.04 FOR ADDITIONAL CITY OF RENTON SUBMITTAL REQUIREMENTS. CONTRACTOR RESPONSIBILITY: FOR SEISMIC DESIGN CATEGORY C, D, E AND F STRUCTURES, THE CONTRACTOR IS RESPONSIBLE FOR THE CONSTRUCTION OF THE MAIN WIND OR SEISMIC FORCE-RESISTING SYSTEM, OR A WIND OR SEISMIC FORCE- RESISTING COMPONENT LISTED IN TABLES 2C, 3 AND 4. THE CONTRACTOR SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON THE SYSTEM OR COMPONENT. THE CONTRACTOR'S STATEMENT OF RESPONSIBILITY SHALL CONTAIN THE FOLLOWING: 1. ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS. 2. ACKNOWLEDGEMENT THAT CONTROL WILL BE EXERCISED TO OBTAIN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS APPROVED BY THE BUILDING OFFICIAL. 3. PROCEDURES FOR EXERCISING CONTROL WITHIN THE CONTRACTOR'S ORGANIZATION, THE METHOD AND FREQUENCY OF REPORTING AND DISTRIBUTION OF THE REPORTS. 4. IDENTIFICATION AND QUALIFICATIONS OF THE PERSON(S) EXERCISING SUCH CONTROL AND THEIR POSITION(S) IN THE ORGANIZATION. STATEMENT OF SPECIAL INSPECTION AND TESTING NOTES: COPY PDF CONTENT FROM TEMPLATE HERE: U:\23000-23999\2300657 -Renton Marketplace\50 - Archive\XX -PDF FOR SHEET S0.03 CONTINUOUS PERIODIC - X - X - X X - - X CONTINUOUS PERIODIC 1704.2.5 - - - WHERE FABRICATION OF STRUCTURAL, LOAD- BEARING OR LATERAL LOAD-RESISTING MEMBERS OR ASSEMBLIES IS BEING PERFORMED ON THE PREMISES OF A FABRICATOR'S SHOP, SPECIAL INSPECTION OF THE FABRICATED ITEMS SHALL BE AS REQUIRED BY TABLE 2 AND AS REQUIRED ELSEWHERE IN THE STATEMENT OF SPECIAL INSPECTIONS. REFERENCE SECTION 1704.2.5.1 FOR APPROVED FABRICATOR EXCEPTION. TB 1705.3(1) 1705.3 1908.1 ACI 318: 20, 25.2-25.3, 26.6.1-26.6.3, 26.8, 26.13.3; AISC 360: N5.8 - X TOLERANCE AND REINFORCING PLACEMENT PER ACI 318: 26.6 TB 1705.3(2) 1705.3.1 - - EXCEPT AS NOTED OTHERWISE - X MANUFACTURER'S CERTIFIED TEST REPORTS - X COPY OF WELDING PROCEDURE SPECIFICATIONS - X COPY OF QUALIFICATION CARDS TB 1705.3 (2.a)- X CERTIFIED MILL TEST REPORTS TB 1705.3 (2.b)- X - TB 1705.3 (2.c)X - ALL WELDS VISUALLY INSPECTED PER AWS D1.4: 9.5 TB 1705.3 (3) WAC 51-50-1705 ACI 318: 26.13.3 AISC 360: N5.8 - X ALL ANCHORS SHALL BE VISUALLY INSPECTED TB 1705.3 (4.a) ACI 355.4 ICC/IAPMO EVALUATION REPORT ACI 318: 26.13.3 X - REFER TO ANCHOR CALLOUTS FOR SUSTAINED TENSION (ST) DESIGNATION TB 1705.3 (4.b) ACI 355.4 ICC/IAPMO EVALUATION REPORT ACI 318: 26.13.3 - X ALL ANCHORS SHALL BE VISUALLY INSPECTED. (SEE SPECIFICATION PART 3 POST-INSTALLED ANCHOR REQUIREMENTS) TB 1705.3(5) 1705.3 1904 1908.1 ACI 318: 19, 26.4.3- 26.4.4, 26.13.3 - X - TB 1705.3(6) 1908.1 ASTM C 31 ASTM C 172 ACI 318: 26.5, 26.12 X - - - ACI 318: 26.13.3.3(c) - X - TB 1705.3(8) 1705.3 1908.1 ACI 318: 26.5.3-26.5.5, 26.13.3 - X - TB 1705.3(14) 1705.3 ACI 318: 26.11.1.2(b) - X - -ICC/IAPMO EVALUATION REPORTS - X VISUALLY INSPECT FOR CORRECT ASSEMBLY AND LOCATION TABLE 2 - REQUIRED STRUCTURAL SPECIAL INSPECTIONS INSPECTION REMARKSFREQUENCY PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS. GEOTECHNICAL REPORT VERIFY USE OF PROPER PROCEDURES, MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF COMPACTED FILL. PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY. TB 1705.6 1705.6 BY THE GEOTECHNICAL ENGINEER TABLE 1 - REQUIRED GEOTECHNICAL SPECIAL INSPECTIONS INSPECTION REMARKSIBC CODE REFERENCE CODE OR STANDARD REFERENCE SYSTEM OR MATERIAL FREQUENCY SOILS VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. INSPECT REINFORCEMENT, INCLUDING EMBEDMENTS AND PRESTRESSING TENDONS, AND VERIFY PLACEMENT. INSPECTION OF REINFORCING STEEL WELDING 1705.3.1 IBC CODE REFERENCE CODE OR STANDARD REFERENCE FABRICATION INSPECTION IN FABRICATION SHOP CONCRETE SYSTEM OR MATERIAL ACI 318: 26.6.4 AWS D1.4: 9 MATERIAL VERIFICATION OF WELD FILLER METALS VERIFYING USE OF PROPER WELDING PROCEDURE SPECIFICATIONS VERIFYING WELDER QUALIFICATIONS VERIFY WELDABILITY OF REINFORCING STEEL OTHER THAN ASTM A 706. ACI 318: 26.6.4 AWS D1.4: 9 INSPECT ALL OTHER WELDS INSPECT SINGLE PASS FILLET WELDS, MAXIMUM 5/16" INSPECT ANCHORS CAST IN CONCRETE VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES. VERIFY CURING METHOD AND DURATION OF CURING FOR EACH MEMBER. INSPECT ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS: ADHESIVE ANCHORS AND ADHESIVE REINFORCING DOWELS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS. MECHANICAL ANCHORS, ADHESIVE ANCHORS, AND ADHESIVE REINFORCING DOWELS NOT DEFINED ABOVE. VERIFY USE OF REQUIRED DESIGN MIX. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED. INSPECT REINFORCING STEEL MECHANICAL COUPLERS, TERMINATORS AND FORM SAVERS X - - - X - - X - X - - X - - X - - X - - X - - X - - - - FABRICATOR OR ERECTOR SHALL OBSERVE X - - X - - X - - X - - X - - - X - X - - - X - - X - - X - - X WHEN WELDING OF DOUBLER PLATES, CONTINUITY PLATES OR STIFFENERS HAS BEEN PERFORMED IN THE K-AREA, VISUALLY INSPECT THE WEB K-AREA FOR CRACKS WITHIN 3 INCHES OF THE WELD. - X AFTER ROLLED HEAVY SHAPES AND BUILT-UP HEAVY SHAPES ARE WELDED, VISUALLY INSPECT THE WELD ACCESS HOLE FOR CRACKS. - X - - X - - X - X - - WPS AVAILABLE FIT-UP OF CJP GROOVE WELDS OF HSS T-, Y- AND K-JOINTS WITHOUT BACKING (INCLUDING JOINT GEOMETRY): JOINT PREPARATIONS, DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL), CLEANLINESS (CONDITION OF STEEL SURFACES), TACKING (TACK WELD QUALITY AND LOCATION) STEEL INSPECTION TASKS PRIOR TO WELDING: WELDER QUALIFICATION RECORDS AND CONTINUITY RECORDS 1705.2 AISC 360: TB N5.4-1 AISC 360: N5.4 MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE 1705.2 AISC 360: TB N5.4-2 AISC 360: N5.4 CONTROL AND HANDLING OF WELDING CONSUMABLES: PACKAGING, EXPOSURE CONTROL NO WELDING OVER CRACKED TACK WELDS MATERIAL IDENTIFICATION (TYPE/GRADE) WELDER IDENTIFICATION SYSTEM FIT-UP OF FILLET WELDS: DIMENSIONS (ALIGNMENT, GAPS AT ROOT), CLEANLINESS (CONDITION OF STEEL SURFACES), TACKING (TACK WELD QUALITY AND LOCATION), BACKING TYPE AND FIT (IF APPLICABLE) CHECK WELDING EQUIPMENT CONFIGURATION AND FINISH OF ACCESS HOLES ENVIRONMENTAL CONDITIONS: WIND SPEED WITHIN LIMITS, PRECIPITATION AND TEMPERATURE PLACEMENT AND INSTALLATION OF STEEL HEADED STUD ANCHORS WPS FOLLOWED: SETTINGS ON WELDING EQUIPMENT, TRAVEL SPEED, SELECTED WELDING MATERIALS, SHIELDING GAS TYPE/FLOW RATE, PREHEAT APPLIED, INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.), PROPER POSITION (F, V, H, OH) WELDING TECHNIQUES: INTERPASS AND FINAL CLEANING, EACH PASS WITHIN PROFILE LIMITATIONS, EACH PASS MEETS QUALITY REQUIREMENTS FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY): JOINT PREPARATIONS, DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL), CLEANLINESS (CONDITION OF STEEL SURFACES), TACKING (TACK WELD QUALITY AND LOCATION), BACKING TYPE AND FIT (IF APPLICABLE) INSPECTION TASKS DURING WELDING: INSPECTION TASKS AFTER WELDING: WELDS CLEANED 1705.2 AISC 360: TB N5.4-3 AISC 360: N5.4 SIZE, LENGTH AND LOCATION OF WELDS WELDS MEET VISUAL ACCEPTANCE CRITERIA: CRACK PROHIBITION, WELD/BASE-METAL FUSION, CRATER CROSS SECTION, WELD PROFILES, WELD SIZE, UNDERCUT, POROSITY ARC STRIKES K-AREA BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED) REPAIR ACTIVITIES NO PROHIBITED WELDS HAVE BEEN ADDED WITHOUT THE APPROVAL OF THE EOR WELD ACCESS HOLES IN ROLLED HEAVY SHAPES AND BUILT-UP HEAVY SHAPES DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER X - - X - - X - - X - - X - - - X - - X - - X - CONTINUOUS PERIODIC - X MANUFACTURER'S CERTIFIED TEST REPORTS - X COPY OF WELDING PROCEDURE SPECIFICATIONS - X COPY OF QUALIFICATION CARDS - AWS D1.3: 8 - X ALL WELDS VISUALLY INSPECTED PER AWS D1.3: 8.1 FASTENERS ARE POSITIONED AS REQUIRED INSPECTION OR EXECUTION TASKS PRIOR TO MECHANICAL FASTENING: 1705.2.2 COLD-FORMED STEEL FRAMING MATERIAL VERIFICATION OF WELDING CONSUMABLES -AISI S100 APP. A J2a, AWS D1.3 SDI QA/QC: APP. 1 SDI QA/QC: APP. 1 MANUFACTURER INSTALLATION INSTRUCTIONS AVAILABLE FOR MECHANICAL FASTENERS PROPER TOOLS AVAILABLE FOR FASTENER INSTALLATION VERIFYING USE OF PROPER WPS VERIFYING WELDER QUALIFICATIONS WELDED FRAMING CONNECTIONS SYSTEM OR MATERIAL INSPECTION REMARKSIBC CODE REFERENCE CODE OR STANDARD REFERENCE FREQUENCY CHECK SPACING, TYPE, AND INSTALLATION OF SUPPORT FASTENERS, SIDELAP FASTENERS, AND PERIMETER FASTENERS VERIFY REPAIR ACTIVITIES DOCUMENT ACCEPTANCE OR REJECTION OF MECHANICAL FASTENERS 1705.2.2 SDI QA/QC: APP. 1 INSPECTION OR EXECUTION TASKS AFTER MECHANICAL FASTENING: PROPER STORAGE FOR MECHANICAL FASTENERS 1705.2.2FASTENERS ARE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS INSPECTION OR EXECUTION TASKS DURING MECHANICAL FASTENING: CONTINUOUS PERIODIC - X - REFERENCE THE STRUCTURAL NOTES IN THE STRUCTURAL DRAWINGS FOR OUTLINE OF SFRS SYSTEM. REFERENCE TABLE 2A FOR MATERIAL SPECIFIC INSPECTION REQUIREMENTS. - X - REFERENCE TABLE N1 AND N2 FOR INSPECTION REQUIREMENTS. OBSERVE PERFORM 1705.13.1 AISC 341: TB J6.3 - X - - X - CONTINUOUS PERIODIC CONTINUOUS PERIODIC 1705.12.3 - - X - GENERAL SEISMIC FORCE-RESISTING SYSTEMS (SFRS) IN STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY B, C, D, E OR F 1704.3.2 1705.12DESIGNATED SEISMIC SYSTEMS (SECONDARY) IN STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY C, D, E OR F TABLE 2A - REQUIRED STRUCTURAL SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE SYSTEM OR MATERIAL INSPECTION REMARKSIBC CODE REFERENCE CODE OR STANDARD REFERENCE FREQUENCY STEEL VISUAL INSPECTION TASKS AFTER WELDING: PLACEMENT OF REINFORCING OR CONTOURING FILLET WELDS (IF REQUIRED) OTHER INSPECTION TASKS: PROTECTED ZONE, NO HOLES AND UNAPPROVED ATTACHMENTS MADE BY FABRICATOR OR ERECTOR, AS APPLICABLE REMARKSIBC CODE REFERENCE CODE OR STANDARD REFERENCE FREQUENCYSYSTEM OR MATERIAL INSPECTION REMARKSIBC CODE REFERENCE CODE OR STANDARD REFERENCE FREQUENCYSYSTEM OR MATERIAL INSPECTION TABLE 2B - REQUIRED STRUCTURAL SPECIAL INSPECTIONS FOR WIND RESISTANCE SYSTEM OR MATERIAL INSPECTION REMARKSIBC CODE REFERENCE INSPECT FASTENING OF ROOF DECK, ROOF FRAMING CONNECTIONS, WALL CONNECTIONS TO ROOF AND FLOOR DIAPHRAGMS AND FRAMING. CODE OR STANDARD REFERENCE FREQUENCY GENERAL CONTINUOUS PERIODIC VARIES; MINIMUM PER IBC APPENDIX J107.5 - X BY THE GEOTECHNICAL ENGINEER VARIES; CLASSIFICATION AND TESTING OF CONTROLLED FILL MATERIALS - X BY THE GEOTECHNICAL ENGINEER FILL IN-PLACE DENSITY OR PREPARED SUBGRADE DENSITY 1705.6 MATERIAL VERIFICATION TABLE 3 - REQUIRED STRUCTURAL TESTING REMARKSIBC CODE REFERENCE CODE OR STANDARD REFERENCE FREQUENCY GEOTECHNICAL SYSTEM OR MATERIAL TESTING ASTM C 172 ACI 318: 26.12 OBTAIN WHEN FRESH CONCRETE IS PLACED FOR EACH MIX DESIGN USED ASTM C 39 ACI 318: 26.12 REFER TO GENERAL NOTES FOR TEST AGE. FOR 6 BY 12-INCH CYLINDERS, 2 CYLINDERS AT TEST AGE IS PERMITTED. CYL = CYLINDER. (SEE SPECIFICATIONS PART 3 CONCRETE TESTING REQUIREMENTS). ASTM C 143 AT POINT OF PLACEMENT ASTM C 231 MIN ONE PER DAY ASTM C 1064 ONE TEST PER HOUR WHEN AIR TEMP IS BELOW 40 DEG F OR ABOVE 80 DEG F AISC 360: N5.5 RT- AWS D1.1: 8.16 MT- AWS D1.1: 8.14.4 UT- AWS D1.1: 8.13 & 8.14.3 ALL CJP WELDS IN MATERIALS 5/16" OR GREATER REQUIRE UT TESTING AISC 341: J6.2a MT - AWS D1.1: 8.14.4 UT - AWS D1.1: 8.13 & 8.14.3 REFER TO DRAWINGS FOR LOCATIONS AISC 341: J6.2b AWS D1.1: 8.14.1 AWS D1.8 - AISC 341: J6.2c AWS D1.1: 8.13 & 8.14.3 - AISC 341: J6.2f AWS D1.1: 8.14.4 - CONCRETE COMPOSITE SAMPLES 1903 1705.3 ONE SAMPLE FOR EA 150 CY NOR LESS THAN 5,000 SQ FT OF SLABS AND WALLS, ONE SET PER DAY MIN CONCRETE STRENGTH, UNO EACH SAMPLE: 1 CYL - 7 DAYS 3 CYL - TEST AGE 1 CYL - HOLD CONCRETE TEMPERATURE ONE TEST PER COMPOSITE SAMPLE CONCRETE SLUMP ONE TEST PER COMPOSITE SAMPLE CONCRETE AIR CONTENT ONE TEST PER COMPOSITE SAMPLE STEEL RADIOGRAPHIC (RT) MAGNETIC PARTICLE (MT) AND ULTRASONIC (UT) TESTING OF WELDS PER DRAWINGS UT OF PARTIAL JOINT PENETRATION (PJP) WELDS AT COLUMN SPLICES AND COLUMNS TO BASE PLATES EACH LOCATION MT OF THE ENDS OF FLANGE WELDS FROM WHICH WELD TABS HAVE BEEN REMOVED EACH LOCATION UT OF BASE METAL THICKER THAN 1-1/2" SUBJECT TO THROUGH-THICKNESS WELD SHRINKAGE STRAINS BEHIND AND ADJACENT TO EACH WELD TABLE 4 - REQUIRED STRUCTURAL TESTING FOR SEISMIC RESISTANCE SYSTEM OR MATERIAL TESTING REMARKSIBC CODE REFERENCE CODE OR STANDARD REFERENCE FREQUENCY STEEL MAGNETIC PARTICLE (MT) AND ULTRASONIC (UT) TESTING OF COMPLETE JOINT PENETRATION GROOVE (CJP) WELDS IN MATERIALS 5/16" THICK AND GREATER UT 100% OF WELDS MT 25% OF WELDS - X - X - - X - - X - - X - - X - - X - - X - - X - - X - - X - - 1705.2 AISC 360: TB N5.6-3 - X - - AISC 360: N5.7 - X - 1705.2 AISC 360: N5.8 - X - INSPECTION OF FABRICATED AND ERECTED STEEL FRAMES: INSPECTION TASKS PRIOR TO BOLTING: MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS 1705.2 AISC 360: TB N5.6-1 AISC 360: N5.6 FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS CORRECT FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE, BOLT LENGTH IF THREADS ARE TO BE EXCLUDED FROM SHEAR PLANE) CORRECT BOLTING PROCEDURE FOR JOINT DETAIL CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE CONDITION AND HOLE PREPARATION, IF SPECIFIED, MEET APPLICABLE REQUIREMENTS PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNEL OBSERVED AND DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS USED PROTECTED STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND OTHER FASTENER COMPONENTS INSPECTION OF GALVANIZED STRUCTURAL STEEL MAIN MEMBERS: VISUALLY INSPECT EXPOSED CUT SURFACES AND EXPOSED CORNERS OF RECTANGULAR HSS FOR CRACKS AFTER GALVANIZATION. VERIFICATION OF COMPLIANCE WITH CONSTRUCTION DOCUMENT DETAILS. INSPECTION TASKS AFTER BOLTING: DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS INSPECTION TASKS DURING BOLTING: FASTENER ASSEMBLIES PLACED IN ALL HOLES AND WASHERS AND NUTS ARE POSITIONED AS REQUIRED 1705.2 AISC 360: TB N5.6-2 AISC 360: N5.6 JOINT BROUGHT TO SNUG-TIGHT CONDITION PRIOR TO THE PRETENSIONING OPERATION FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM ROTATING FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC SPECIFICATION, PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID POINT TOWARD THE FREE EDGES - X - - X - - X - - X - - X - X - - X - - X - - X - - X - - X - - X - - X - - - X - - X - - X - - X - INSPECTION OR EXECUTION TASKS AFTER DECK PLACEMENT: VERIFY COMPLIANCE OF MATERIALS (DECK AND ALL DECK ACCESSORIES) WITH CONSTRUCTION DOCUMENTS, INCLUDING PROFILES, MATERIAL PROPERTIES, AND BASE METAL THICKNESS DOCUMENT ACCEPTANCE OR REJECTION OF DECK AND DECK ACCESSORIES CONSTRUCTION DOCUMENT DETAILS. INSPECTION OR EXECUTION TASKS AFTER WELDING: SDI QA/QC: APP. 1 STEEL DECK SDI QA/QC: APP. 1 INSPECTION OR EXECUTION TASKS PRIOR TO DECK PLACEMENT: VERIFY COMPLIANCE OF DECK AND ALL DECK ACCESSORIES INSTALLATION WITH CONSTRUCTION DOCUMENTS VERIFY DECK MATERIALS ARE REPRESENTED BY THE MILL CERTIFICATIONS THAT COMPLY WITH THE CONSTRUCTION DOCUMENTS INSPECTION OR EXECUTION TASKS PRIOR TO WELDING: SDI QA/QC: APP. 1 MATERIAL IDENTIFICATION (TYPE/GRADE) CHECK WELDING EQUIPMENT DOCUMENT ACCEPTANCE OR REJECTION OF INSTALLATION OF DECK AND DECK ACCESSORIES 1705.2.2 1705.2.2 ENVIRONMENTAL CONDITIONS (WIND SPEED, MOISTURE, TEMPERATURE) DOCUMENT ACCEPTANCE OR REJECTION OF WELDS MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE USE OF QUALIFIED WELDERS WPS FOLLOWED INSPECTION OR EXECUTION TASKS DURING WELDING: CONTROL AND HANDLING OF WELDING CONSUMABLES 1705.2.2 SDI QA/QC: APP. 1WELDS MEET VISUAL ACCEPTANCE CRITERIA VERIFY SIZE AND LOCATION OF WELDS, INCLUDING SUPPORT, SIDELAP, AND PERIMETER WELDS VERIFY REPAIR ACTIVITIES WELDING PROCEDURE SPECIFICATIONS (WPS) AVAILABLE 1705.2.2 SDI QA/QC: APP. 1 1705.2.2 CONTINUOUS PERIODIC TABLE 2 - REQUIRED STRUCTURAL SPECIAL INSPECTIONS INSPECTION REMARKSFREQUENCYIBC CODE REFERENCE CODE OR STANDARD REFERENCE SYSTEM OR MATERIAL RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT T-433450 PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 50 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com TR O - 4 1 - 4 3 3 4 07/16/25 61 47248 AMI E E . SULLI V A N S T R UCTURAL E N G I N EERP R O F E SSI ONA L E N G I N EER STAT E O F WASHIN G T O N DEVELOPMENT ENGINEERING msippo 08/13/2025 R-433450 TE D - 4 0 - 4 3 3 4 PR I N T E D : FI L E : IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: SHEET: PAGE: OF: Planning/Building/Public Works Dept. CITY OF RENTON DATUM SURVEYED: DESIGNED: DRAWN: CHECKED: APPROVED: SCALE:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLYAPPRDATEBYREVISIONNO. 4/ 4 / 2 0 2 5 1 1 : 4 2 : 2 0 A M C : \ R e v i t M o d e l s \ 2 0 2 3 \ 2 2 3 3 - R e n t o n P a v i l i o n - S T R U C - R 2 0 2 3 _ p e t e r . z e r k e l . r v t S0.04 STATEMENT OF SPECIAL INSPECTION AND TESTING TR O - 4 1 - 4 3 3 4 STATEMENT OF SPECIAL INSPECTIONS AND TESTING THE FOLLOWING SUBMITTAL REQUIREMENTS ARE IN ADDITION TO REQUIREMENTS NOTED ELSEWHERE. REPORTS, CERTIFICATES AND OTHER DOCUMENTS RELATED TO STRUCTURAL SPECIAL INSPECTIONS AND TESTS SHOULD BE SUBMITTED BY THE CONTRACTOR TO THE CITY OF RENTON. THE CERTIFICATES OF COMPLIANCE ARE REQUIRED TO STATE THAT THE WORK WAS PERFORMED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. 1. SUBMITTAL OF WELDING PROCEDURE SPECIFICATIONS FOR THE WELDING OF CONCRETE REINFORCEMENT OTHER THAN BY FILLET WELDS NOT PERFORMED WITH GTAW. SEE ALSO IBC SECTION 1901.2, SECTION 26.6.4.2 OF ACI 318-19, AND SECTION 8.1.2 OF AWS D1.4-18. 2. SUBMITTAL OF CERTIFICATES OF COMPLIANCE FROM THE FABRICATORS OF STRUCTURAL STEEL MEMBERS AT THE COMPLETION OF FABRICATION, SEE ALSO IBC SECTIONS 1704.2.5 AND 1704.2.5.1. 3. SUBMITTAL OF CERTIFICATES OF COMPLIANCE FROM THE FABRICATORS OF PREFABRICATED STRUCTURAL STEEL MOMENT FRAMES AT THE COMPLETION OF FABRICATION. SEE ALSO IBC SECTIONS 1704.2.5 AND 1704.2.5.1. 4. SUBMITTAL OF WELDING PROCEDURE SPECIFICATIONS VERIFYING THAT THE WELDS AT MEMBERS AND CONNECTIONS OF THE SEISMIC-FORCE-RESISTING SYSTEM ARE MADE WITH THE FILLER METAL PRODUCING WELDS WITH A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FT-LBF AT 0 DEGREES-F [25 FT-LBF AT MINUS 20 DEGREES-F (FOR 90 KSI FILLER METAL CLASSIFICATION)] AS DETERMINED BY THE APPLICABLE AWS A5 CLASSIFICATION TEST METHOD. SEE ALSO IBC SECTIONS 104.1, 107.3.4.1, AND 2205.2.1.2, SECTIONS A3.4A AND A2(B) OF AISC 341-16, SECTION 6.1 AND TABLE 6.1 OF AWS D1.8-16, AND SECTIONS 2.3.2 AND 4.2.1.3 OF AWS D1.1-15. 5. SUBMITTAL OF WELDING PROCEDURE SPECIFICATIONS VERIFYING THAT DEMAND-CRITICAL WELDS ARE MADE WITH FILLER METAL PRODUCING WELDS WITH A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FT- LBF AT MINUS 0 DEGREES-F AS DETERMINED BY THE APPLICABLE AWS A5 CLASSIFICATION TEST METHOD AND 40 FT-LBF AT 10 DEGREES-F (NOTING THE LAST IS -10 DEGREES-F). SEE ALSO IBC SECTIONS 104.1, 107.3.4.1, AND 2205.2.1.2, SECTIONS A3.4A AND A2(B) OF AISC 341-16, SECTION 6.1 AND TABLE 6.2 OF AWS D1.8-16, AND SECTIONS 2.3.2 AND 4.2.1.3 OF AWS D1.1-15. 6. SUBMITTAL OF WELDING PROCEDURE SPECIFICATIONS FOR THE WELDING OF REINFORCING STEEL OTHER THAN BY PREQUALIFIED WELDING PROCEDURE SPECIFICATIONS. PLEASE NOTE, THAT AWS D1.4-18 INDICATES THAT ONLY FILLET WELDS NOT PERFORMED USING GTAW FOR REINFORCING STEEL IS PREQUALIFIED, AND NOT THE PROPOSED GROVE WELDS. THIS INFORMATION IS NEED BY THE SPECIAL INSPECTOR TO VERIFY THE WORK IS COMPLETED IN ACCORDANCE WITH AWS D1.4-18 STANDARDS AND THUS THE 2021 IBC. SEE IBC SECTIONS 107.2.1, 1705.3, 1901.2 AS WELL AS ACI 318-19 SECTION 26.6.4, AND AWS D1.4-18 SECTION 8.1.2.1. 7. SUBMITTAL OF WELDING PROCEDURE SPECIFICATIONS FOR THE WELDING OF STRUCTURAL STEEL OTHER THAN BY PREQUALIFIED WELDING PROCEDURE SPECIFICATIONS. SEE ALSO IBC 2205.1, SECTION A2 OF AISC 360-16, AND SECTION 3.1 OF AWS D1.1-15.S CITY OF RENTON SUBMITTAL REQUIREMENTS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT T-433451 51 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com 07/16/25 61 47248 AMI E E . SULLI V A N S T R UCTURAL E N G I N EERP R O F E SSI ONA L E N G I N EER STAT E O F WASHIN G T O N PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 DEVELOPMENT ENGINEERING msippo 08/13/2025 TE D - 4 0 - 4 3 3 4 R-433451 PLANTER SOIL T/SIDEWALK PLINTH TIES AND VERTS PER 5'-0" 2'- 0 " 1'- 6 " (5) #4 OC EW, T&B 6" 18 ' - 0 " 1 1 / 2 " 1 1 / 2 " ANCHOR BOLTS PER LIGHT POLE MFR  2  S4.05 ____ COMPACTED STRUCTURAL FILL PER GENERAL NOTES LIGHT POLE PER LANDSCAPE ARCH 2/S4.05 5'-0"x5'-0"x24" FOUNDATION NOTES: 1. LOCATE MAST POLES PER LANDSCAPE ARCHITECT. 2. CONTRACTOR TO COORDINATE FOUNDATION LOCATIONS WITH EXISTING UTILITIES AND CIVIL DRAWINGS. NOTIFY ARCHITECT OF ANY DISCREPNACIES. CL FOOTING CL POLE 1 /2 " R SPIRAL #4 @ 4" OC, DEVELP SPIRAL W/ 1 1/2 EXTRA TURNS AT EACH END OF CAGE ANCHOR BOLTS PER LIGHT POLE MFR (6) #5 VERTSDISTRIBUTED UNIFORMLY AROUND COLUMN PERIMETER 12" Ø PLINTH TIES AND VERTS PER (8) #8 VERT T&B BASE PL PER PIPE 10 X-STRONG AESS CATENARY LIGHTS AND CABLE PROFILE PER 8'-0" 2' - 6 " 1 1 / 2 " 6/S4.05 1'-0" POLE CAN ACCOMODATE MAX 2'-0" x 4'-0" DECORATIVE BANNER 8'-0"x5'-0"x30" FOUNDATION (8) #8 HORIZ T&B 10/S4.05 POLE CAN ACCOMODATE (2) 60 LBS MAX DECORATIVE FLOWER BASKETS  6  S4.05 ____ SIDEWALK PER CIVIL GR O U T 1 1 / 2 " N O N S H R I N K RONSTAN ACS1-SS-08 OR EOR APPROVED EQUIVALENT ROUNDED CAP PL 1/8" W/ 8" RADIUS SEAL WELD 9/S4.05 1' - 0 " NOTES: 1. LOCATE LOGAN AVE POLES PER CIVIL. 2. CONTRACTOR TO COORDINATE FOUNDATION LOCATIONS WITH EXISTING UTILITIES AND CIVIL DRAWINGS. NOTIFY ARCHITECT OF ANY DISCREPNACIES. 3. PAINT PER LANDSCAPE ARCHITECT. COMPACTED STRUCTURAL FILL PER GENERAL NOTES CL POLE 2' - 0 " 1 1 / 2 " 17 ' - 6 " M A X 20 ' - 0 " 22 ' - 0 " 2'-0" 4" ACCESS DOOR PER , LOCATE PER LANDSCAPE ARCH ACCESS DOOR PER 1/S4.05 FOR OUTLET, COORD W/ ELECTRICAL 9' - 0 " ESCUTCHION COVER PLATE PER LANDSCAPE ARCH 1/S4.05 (4) 3/8"Ø WEEP HOLES EQ SPACED AROUND BASE CATENARY CONN CABLE PER 5/S4.05 PL1 1/2x16x1'-4" (4) 1"Ø GR 105 GALV ANCHOR RODS W/ 24" EMBED POLE PER PLINTH PER 3/8 11/S4.05 6/S4.05 TY P 2" TYP 2" 1.5"Ø MAX HOLE, COORD WITH ELECTRICAL #4 @ 4" OC TIES (12) #7 VERTS 2'-0" 2' - 0 " POLE PER TYP 22'-8" MAX 22'-8" MIN 22'-8" MAX 18 " M A X 12 " M I N 68'-0" MAX 11/S4.05 MAX 25 LB LIGHT, (2) LOCS PER CABLE 3/4"Ø MAX HOLE W/ SEALING GROMMET, COORD SIZE AND LOC WITH ELECTRICAL; SUBMIT SEALING GROMMET TO ARCHITECT FOR REVIEW PIPE EXTERIOR FACE 3/16 3/16 1 1/2" 3/4" 1/2" Ø 3/4" R 1 1 NOTES: 1. ORIENT TAB TO ALIGN WITH CATENARY CABLE LAYOUT PER LANDSCAPE ARCHITECT. PL 3/8"ACS1 COMPACT ADJUSTER AND CLEVIS PER RONSTAN OR APPROVED EQUIVALENT CABLE PER 11/S4.05 CURVED PL 1/4x2x0'-4 1/2" T&B; DRILL AND TAP TO RECEIVE SECURITY SCREW PIPE EXTERIOR FACE 1/8 3 SIDES 1/16" MAX GAP AT PERIMETER 1/ 2 " 1" OPENING 4" WIDE x 9" TALL W/ 1/2" RADIUSED CORNERS 1/4"Ø GALV SECURITY SCREW W/ RECESSED HEAD T&B, CTR ON PL 1/4" BEVEL REMOVABLE ACCESS DOOR, MATCH PIPE PROFILE PR I N T E D : FI L E : IN COMPLIANCE WITH CITY OF RENTON STANDARDS DATE: FIELDBOOK: DRAWING NO: SHEET: PAGE: OF: Planning/Building/Public Works Dept. CITY OF RENTON DATUM SURVEYED: DESIGNED: DRAWN: CHECKED: APPROVED: SCALE:VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLYAPPRDATEBYREVISIONNO. 7/ 1 5 / 2 0 2 5 1 0 : 5 7 : 0 3 A M C : \ R e v i t M o d e l s \ 2 0 2 3 \ 2 2 3 3 - R e n t on P a v i l i o n - S T R U C - R 2 0 2 3 _ p e t e r . z e r k e l . r v t S4.05SITE TYPICAL DETAILS 1/2" = 1'-0"12 TYP MAST LIGHT POLE ELEVATION 1" = 1'-0"2 TYPICAL LIGHT POLE PLINTH 1/2" = 1'-0"11 LOGAN AVE POLE ELEVATION 1" = 1'-0"10 LOGAN AVE POLE BASEPLATE 1" = 1'-0"6 LOGAN AVE PLINTH 1/16" = 1'-0"9 CATENARY LIGHT CABLE PROFILE 3" = 1'-0"5 CATENARY CABLE CONNECTION 3" = 1'-0"1 SECTION AT ACCESS DOOR PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TR O - 4 1 - 4 3 3 4 T-433452 RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT 07/16/25 6152 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com 47248 AMI E E . SULLI V A N S T R UCTURAL E N G I N EERP R O F E SSI ONA L E N G I N EER STAT E O F WASHIN G T O N DEVELOPMENT ENGINEERING msippo 08/13/2025 T-433401 BU R N E T T A V E S WELLS AVE S BU R N E T T P L S MILL AVE S N RIVERSIDE DR MAIN AVE S S 2ND ST S 2ND ST N 1ST ST CEDAR AVE S WIL L I A M S A V E S BURNETT AVE S SHATTUCK AVE S MORRIS AVE S S 3RD ST MORRIS AVE S S 3RD ST S TOBIN ST WE L L S A V E S SH A T T U C K A V E S S 4TH ST MO R R I S A V E S SH A T T U C K A V E S BURNETT AVE S S 3RD PL MIL L A V E S HOUSER WAY SWILLIAMS AVE S S 4TH ST HOUSER WAY S LOGAN AVE S S 3RD ST S 2ND ST BURNETT AVE S S 2ND ST BURNETT AVE S S 3RD ST S 2ND ST N RIVERSIDE DR S TOBIN ST S 4TH ST SM I T H E R S A V E S WILLIAMS AVE S S 3RD ST PELLY AVE N MAIN AVE S S 4TH ST WILLIAMS AVE S HOUSER WAY S LO G A N A V E S MILL AVE S WHITWORTH AVE S MAIN AVE S WELLS AVE S S 4TH ST BRONSON WAY N S 3RD ST S 4TH ST MA I N A V E S WILLIAMS AVE S S 4TH ST S 3RD ST S 3RD ST WHITWORTH AVE S SMITHERS AVE S WELLS AVE S WH I T W O R T H A V E S S 2ND ST HOUSER W A Y S WILLIAMS AVE S S 2ND ST LOGAN AVE S S 2ND ST MAIN AVE S S 2ND ST HOUSER WAY S S TOBIN STS TOBIN ST MORRIS AVE S WELLS AVE S WELLS AVE S N 1ST ST SHATTUCK AVE S S 4TH PL HOUSER WAY S HOUSER WAY S SHATTUCK AVE S BRONSON WAY N MAIN AVE S S 3RD ST S 3RD ST BRONSON WAY N S 2ND STS 2ND ST S 2ND ST SMITHERS AVE S S 2ND ST S 2ND ST I-405 FWY PROJECT LOCATION Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 VICINITY MAP 1" = 500'±RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT COVER R-433401 1 61 7 / 16 / 2025 TR O - 4 1 - 4 3 3 4 61 NTS E0.01 T-433407 ELECTRICAL - ABBREV., GENERAL NOTES, LEGENDS, AND DRAWING LIST 53 ϭϲϬϭ ϱƚŚ ǀĞŶƵĞ͕ ^ƵŝƚĞ ϭϲϬϬ ^ĞĂƚƚůĞ͕ t ϵϴϭϬϭ ϮϬϲ͘ϲϮϮ͘ϱϴϮϮ ZZZNSIIFRP Arup US, Inc. 1191 Second Avenue Suite 400 Seattle WA 98101 T +1 206 493 2258 F + 1 206 749 0665 BU R N E T T A V E S BU R N E T T P L S WIL L I A M S A V E S S TOBIN ST WE L L S A V E S SH A T T U C K A V E S MO R R I S A V E S SH A T T U C K A V E S MIL L A V E S LO G A N A V E S MA I N A V E S WH I T W O R T H A V E S HOUSER W A Y S S TOBIN ST S 3RD ST S 2ND ST PROJECT LOCATION AD AREA DRAIN AVE AVENUE CB CATCH BASIN CL CENTER LINE COR CITY OF RENTON CSBC CRUSHED SURFACE BASE COURSE DEMO DEMOLISH ELECT ELECTRICAL ELELEV ELEVATION E;E;ISTE;ISTING GI GREASE INTERCEPTOR HMA HOT MI; ASPHALT IE INVERT ELEVATION LF LINEAR FOOT LS LANDSCAPELANDSCAPING MA;MA;IMUM MIN MINIMUM NTS NOT TO SCALE PLUMB PLUMBING ROW RIGHT OF WAY SD STORE DRAIN SS SANITARY SEWER STD STANDARD TYP TYPICAL W WATER NUMBER 9,C,1,7< 0$3 1" = 500'± RENTON PIA==A CI9IL CONSTR8CTION PERMIT $%%5(9,$7,216 CONTRACTOR IS ALERTED TO THE FACT THAT WORK WILL BE ACCOMPLISHED AROUND ACTIVE PSE GAS AND ENERGI=ED FACILITIES THAT ARE SERVING E;ISTING CUSTOMERS CONTRACTOR SHALL COORDINATE WITH PSE TO DETERMINE WHICH FACILITIES ARE ACTIVE AND ENERGI=ED AND SHALL IMPLEMENT SAFETY PROCEDURES PER PSE RE4UIREMENTS CONTRACTOR SHALL COORDINATE WITH PSE TO ENSURE THAT FACILITIES ARE IN PLACE TO MAINTAIN SERVICE TO CUSTOMERS THROUGHOUT CONSTRUCTION ,1&203/,$1&(:,7+&,7<2)5(172167$1'$5'6 SINGLE LINE DIAGRAMPOWER SYMBOL DESCRIPTION ABBREVIATIONS (CON'T) 1. ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE 2023 NATIONAL ELECTRICAL CODE AND APPLICABLE LOCAL CODES AND REGULATIONS: 2021 INTERNATIONAL BUILDING CODE - WAC 51-50 2021 INTERNATIONAL EXISTING BUILDING CODE - WAC 51-50-4800 2021 WASHINGTON STATE ENERGY CODE (WSEC) 2. DRAWINGS SHOW A COMBINATION OF NEW AND EXISTING SYSTEMS. HALFTONE DENOTES EXISTING TO REMAIN. BLACK LINES INDICATE NEW OR RELOCATED EQUIPMENT OR DEVICES. 3. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED. FOLLOW DRAWINGS IN LAYING OUT WORK AND CHECK DRAWINGS OF OTHER TRADES TO VERIFY SPACE IN WHICH WORK WILL BE INSTALLED. MAINTAIN HEADROOM AND SPACE CONDITIONS AT ALL TIMES. 4. ALL OUTLETS, CONTROL DEVICES, ETC. ARE ILLUSTRATED IN THE APPROXIMATE LOCATION ON THESE DRAWINGS. SEE ARCHITECTURAL PLANS, ELEVATIONS, AND DETAILS FOR ADDITIONAL GUIDELINES FOR MOUNTING DEVICES. 5. CIRCUIT NUMBERS SHOWN THROUGHOUT THE FLOOR PLANS INDICATE DEVICES CONNECTED ON A COMMON CIRCUIT. MAKE ALL CONNECTIONS IMPLIED BY THE CIRCUIT NUMBERS. HOMERUNS INDICATING PANEL NAME ARE SHOWN IN QUANTITIES AND LOCATIONS CHOSEN FOR GRAPHICAL CLARITY. MULTIPLE HOMERUNS ON A SINGLE CIRCUIT SHALL BE COMBINED INTO A SINGLE HOMERUN TERMINATING AT THE PANELBOARD. 6. REFER TO STRUCTURAL DRAWINGS AND SPECIFICATIONS FOR ELECTRICAL EQUIPMENT ANCHORAGE DETAILS AND REQUIREMENTS, AND FOR REINFORCING REQUIREMENTS AT PENETRATIONS THROUGH WALLS, SLABS, AND FOUNDATIONS. 7. WHERE TWO OR MORE SWITCHES AND/OR CONTROL DEVICES ARE SHOWN CO-LOCATED, PROVIDE MULTIPLE GANG BACK BOX WITH A COMMON FACEPLATE. GENERAL NOTES E1.00 ELECTRICAL - SITE PLAN 1" = 25'-0" E5.01 ELECTRICAL - SINGLE LINE DIAGRAM AND ENLARGED PLAN NTS E9.01 ELECTRICAL - PANELBOARD SCHEDULES NTS ED1.00 ELECTRICAL - DEMO SITE PLAN 1/16" = 1'-0" E0.05 ENERGY CODE FORMS NTS E0.03 E0.06 E1.00P - PIAZZA - PIAZZA - PIAZZA - PIAZZA DEVELOPMENT ENGINEERING msippo 08/13/2025 T-433402 BU R N E T T A V E S WELLS AVE S BU R N E T T P L S MILL AVE S N RIVERSIDE DR MAIN AVE S S 2ND ST S 2ND ST N 1ST ST CEDAR AVE S WIL L I A M S A V E S BURNETT AVE S SHATTUCK AVE S MORRIS AVE S S 3RD ST MORRIS AVE S S 3RD ST S TOBIN ST WE L L S A V E S SH A T T U C K A V E S S 4TH ST MO R R I S A V E S SH A T T U C K A V E S BURNETT AVE S S 3RD PL MIL L A V E S HOUSER WAY SWILLIAMS AVE S S 4TH ST HOUSER WAY S LOGAN AVE S S 3RD ST S 2ND ST BURNETT AVE S S 2ND ST BURNETT AVE S S 3RD ST S 2ND ST N RIVERSIDE DR S TOBIN ST S 4TH ST SM I T H E R S A V E S WILLIAMS AVE S S 3RD ST PELLY AVE N MAIN AVE S S 4TH ST WILLIAMS AVE S HOUSER WAY S LO G A N A V E S MILL AVE S WHITWORTH AVE S MAIN AVE S WELLS AVE S S 4TH ST BRONSON WAY N S 3RD ST S 4TH ST MA I N A V E S WILLIAMS AVE S S 4TH ST S 3RD ST S 3RD ST WHITWORTH AVE S SMITHERS AVE S WELLS AVE S WH I T W O R T H A V E S S 2ND ST HOUSER W A Y S WILLIAMS AVE S S 2ND ST LOGAN AVE S S 2ND ST MAIN AVE S S 2ND ST HOUSER WAY S S TOBIN STS TOBIN ST MORRIS AVE S WELLS AVE S WELLS AVE S N 1ST ST SHATTUCK AVE S S 4TH PL HOUSER WAY S HOUSER WAY S SHATTUCK AVE S BRONSON WAY N MAIN AVE S S 3RD ST S 3RD ST BRONSON WAY N S 2ND STS 2ND ST S 2ND ST SMITHERS AVE S S 2ND ST S 2ND ST I-405 FWY PROJECT LOCATION Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 VICINITY MAP 1" = 500'±RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT COVER R-433401 1 61 7 / 16 / 2025 TR O - 4 1 - 4 3 3 4 61 NTS E0.03 T-433408 ELECTRICAL - DESIGN CRITERIA AND LOAD CALCULATIONS - PIAZZA 54 ϭϲϬϭ ϱƚŚ ǀĞŶƵĞ͕ ^ƵŝƚĞ ϭϲϬϬ ^ĞĂƚƚůĞ͕ t ϵϴϭϬϭ ϮϬϲ͘ϲϮϮ͘ϱϴϮϮ ZZZNSIIFRP Arup US, Inc. 1191 Second Avenue Suite 400 Seattle WA 98101 T +1 206 493 2258 F + 1 206 749 0665 EXISTING LIGHTING CONTROLS TO REMAIN. CONTROLS FOR ALL NEW EXTERIOR FIXTURES SHALL MEET WASHINGTON STATE ENERGY CODE REQUIREMENTS FOR EXTERIOR LIGHTING POWER ALLOWANCES AND CONTROLS: - PHOTOCELL FOR AUTOMATIC SHUTOFF WHEN DAYLIGHT IS PRESENT - TIMECLOCK PROGRAMMED FOR BUSINESS HOURS, AFTER HOURS, AND EVENING. PER WSEC FOR EXISTING BUILDINGS (C503.6.1) "ALTERATIONS THAT REPLACE 20 PERCENT OR MORE OF THE TOTAL INSTALLED WATTAGE OF EXTERIOR LUMINAIRES SHALL COMPLY WITH SECTIONS WITH SECTIONS C405.4 and C405.5. WHERE ... LESS THAN 20 PERCENT OF THE INSTALLED EXTERIOR WATTAGE IS REPLACED, THE INSTALLED LIGHTING WATTAGE SHALL BE MAINTAINED OR REDUCED." FINAL LOAD CALCULATIONS INDICATE TOTAL ADDED FIXTURE WATTAGE IS LESS THAN 20 PERCENT OF THE TOTAL SITE LIGHTING POWER, AND REDUCES THE TOTAL SITE LIGHTING POWER: - EXISTING EXTERIOR LIGHTING POWER (PRIOR TO ALTERATION): 7160 VA - PROPOSED NEW EXTERIOR LIGHTING ADDITION: 1419 VA (19.8%) - TOTAL PROPOSED NEW EXTERIOR LIGHTING POWER: 3319 VA SITE EXTERIOR LIGHTING ZONE: ZONE 2 NUMBERED NOTES: 1. EXISTING LIGHT FIXTURE DATA BASED ON PIAZZA AS-BUILTS DATED 11/7/2000. 2. FIXTURES MOUNTED ON 18' POLE. EACH POLE HAS (3) FIXTURE HEADS + (2) PROJECTOR HEADS. (E) A2 DOUBLE HEAD POLE MOUNTED LIGHT (12')240 V 200 W METAL HALIDE --POLE MOUNTED -- (E) A3 DOUBLE HEAD POLE MOUNTED LIGHT (16')240 V 200 W METAL HALIDE --POLE MOUNTED -- (E) C LINEAR LIGHT TUBE 120 V 300 W METAL HALIDE --RECESSED -- (N) F1 MAST POLE MOUNTED FIXTURE 120 V 39 W 4500 3000K POLE MOUNTED SELUX (N) F2 CATENARY FIXTURE 120 V 43 W 3645 3000k CATENARY HESS LED LED PEN380X 30K DIM UNV T5 OLIVIO GRANDE 1 1 1 2 2OLIVIO GRANDE GOBO PROJECTOR(N) F1A MAST POLE MOUNTED PROJECTOR 120 V 49 W -6500K POLE MOUNTED SELUXLED 䱉䝈呉乇 2021 WASHINGTON STATE ENERGY CODE (WSEC) TIMECLOCK HOURS SCHEDULE DAY OF WEEK SPACE TYPE LIGHTING SEQUENCE OF OPERATIONS DESCRIPTION DIM M I N G CON T R O L L E D RE C E P T A C L E S DAY L I G H T RE S P O N S E OC CU P A N C Y SE N S O R S TIM E C L O C K NE T W O R K E D LOC A L CO N T R O L S INTERIOR LIGHTINGEXTERIOR LIGHTING PIAZZA LOGAN STREET CATENARY 50 fc 50 fc L1 L1 X PHOTOCELL TURNS LIGHTS ON/OFF. TIMECLOCK PROVIDES ADDITIONAL AFTER HOURS CONTROL. MANUAL CONTROLS TO ALLOW FOR MANUAL OVERRIDE. SCENE CONTROL FOR GOBO PROJECTOR FIXTURE HEADS. PHOTOCELL TURNS LIGHTS ON/OFF. TIMECLOCK PROVIDES ADDITIONAL AFTER HOURS CONTROL. MANUAL CONTROLS TO ALLOW FOR MANUAL OVERRIDE. T1 T1X X NORMAL LIGHTING: CRITERIA COORDINATED WITH ARCHITECT ON 11/22/2024. SPACE E (AVG HORIZONTAL ILLUMINATION AT FLOOR) PIAZZA 2 FC LOGAN ST CATENARY 3.8 FC EGRESS AND EMERGENCY LIGHTING: EXISTING INSTALLATION DOES NOT INCLUDE ANY BACKUP POWER FOR SITE LIGHTING. PIAZZA LIGHTING DESIGN CRITERIA PIAZZA LIGHTING SEQUENCE OF OPERATIONS PIAZZA LIGHTING FIXTURE SCHEDULE 240 V 3 3. 240V SINGLE PHASE CONNECTION REQUIRED FOR POWER FROM UTILITY SERVICE CABINET. PROVIDE CIRCUITS IN SCHEDULE 80 PVC, 2" MINIMUM, PER CITY OF RENTON. COORDINATE ALL CIRCUITING AND INSTALLATION REQUIREMENTS WITH CITY OF RENTON AND WORLD CUP LEGACY SQUARE PROJECT DESIGNERS. DEVELOPMENT ENGINEERING msippo 08/13/2025 TRANSPORTATION OPERATION CBarnes 08/15/2025 T-433403 BU R N E T T A V E S WELLS AVE S BU R N E T T P L S MILL AVE S N RIVERSIDE DR MAIN AVE S S 2ND ST S 2ND ST N 1ST ST CEDAR AVE S WIL L I A M S A V E S BURNETT AVE S SHATTUCK AVE S MORRIS AVE S S 3RD ST MORRIS AVE S S 3RD ST S TOBIN ST WE L L S A V E S SH A T T U C K A V E S S 4TH ST MO R R I S A V E S SH A T T U C K A V E S BURNETT AVE S S 3RD PL MIL L A V E S HOUSER WAY SWILLIAMS AVE S S 4TH ST HOUSER WAY S LOGAN AVE S S 3RD ST S 2ND ST BURNETT AVE S S 2ND ST BURNETT AVE S S 3RD ST S 2ND ST N RIVERSIDE DR S TOBIN ST S 4TH ST SM I T H E R S A V E S WILLIAMS AVE S S 3RD ST PELLY AVE N MAIN AVE S S 4TH ST WILLIAMS AVE S HOUSER WAY S LO G A N A V E S MILL AVE S WHITWORTH AVE S MAIN AVE S WELLS AVE S S 4TH ST BRONSON WAY N S 3RD ST S 4TH ST MA I N A V E S WILLIAMS AVE S S 4TH ST S 3RD ST S 3RD ST WHITWORTH AVE S SMITHERS AVE S WELLS AVE S WH I T W O R T H A V E S S 2ND ST HOUSER W A Y S WILLIAMS AVE S S 2ND ST LOGAN AVE S S 2ND ST MAIN AVE S S 2ND ST HOUSER WAY S S TOBIN STS TOBIN ST MORRIS AVE S WELLS AVE S WELLS AVE S N 1ST ST SHATTUCK AVE S S 4TH PL HOUSER WAY S HOUSER WAY S SHATTUCK AVE S BRONSON WAY N MAIN AVE S S 3RD ST S 3RD ST BRONSON WAY N S 2ND STS 2ND ST S 2ND ST SMITHERS AVE S S 2ND ST S 2ND ST I-405 FWY PROJECT LOCATION Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 VICINITY MAP 1" = 500'±RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT COVER R-433401 1 61 7 / 16 / 2025 TR O - 4 1 - 4 3 3 4 61 NTS E0.06 T-433409 ELECTRICAL - ENERGY CODE FORMS - PIAZZA 55 ϭϲϬϭ ϱƚŚ ǀĞŶƵĞ͕ ^ƵŝƚĞ ϭϲϬϬ ^ĞĂƚƚůĞ͕ t ϵϴϭϬϭ ϮϬϲ͘ϲϮϮ͘ϱϴϮϮ ZZZNSIIFRP Arup US, Inc. 1191 Second Avenue Suite 400 Seattle WA 98101 T +1 206 493 2258 F + 1 206 749 0665 $GPLQLVWHUHGE\‹1(($$OOULJKWVUHVHUYHG 'DWH'Hc  /,*+7,1*&203/,$1&(6800$5< :6(&&RPSOLDQFH)RUPVIRU&RPPHUFLDO%XLOGLQJVLQFOXGLQJ*URXS55 5RYHUVWRULHVDQGDOO5 3UoMHcW $ppOLcDQW ,QfoUmDWLoQ 3UoMHcW7LWOH 5HQWRQ3LD]]D:6(&)RU%XLOGLQJ'HSDUWPHQW8VH 3UoMHcW$GGUHVV %XUQHWW$YH6RXWK 5HQWRQ:$ $ppOLcDQW1DmH (ULQ5LFKPRQG $ppOLcDQW3KoQH  $ppOLcDQW(mDLO HULQULFKPRQG#DUXSFRP )RUTXHVWLRQVDERXWWKLVUHSRUWFRQWDFW:6(&&RPPHUFLDO7HFKQLFDO6XSSRUWDWRUYLDHPDLODWFRPWHFKVXSSRUW#ZDHQHUJ\FRGHVFRP *HQHUDO2ccXpDQc\$OO&RPPHUFLDO*HQHUDO%XLOGLQJ8VH7\pH >2WKHU%XLOGLQJ8VH7\SH@ %XLOGLQJ&oQG.)OooU$UHD  *HQHUDO3UoMHcW7\pHV$OWHUDWLRQ 1Hw%XLOGLQJoU $GGLWLoQ /LJKWLQJ6copH $OWHUDWLoQ /LJKWLQJ6copH ([WHULRU/LJKWLQJ 3UoMHcW&oQG.)OooU$UHD  )OooUV$EoYH*UDGH  &ompOLDQcH0HWKoG *HQHUDO3UHVFULSWLYH /LJKWLQJ3UoMHcW 'HVcULpWLoQ 6LWHOLJKWLQJXSJUDGHVWRWKHH[LVWLQJSLD]]D /LJKWLQJ&ompOLDQcH 6copH DQG0HWKoG 3UoMHcW7\pH ,QWHULoU([WHULoU ,QWHULoULQcOXGHVEoWKLQWHULoU pDUkLQJ /XmLQDLUH5HpODcHmHQW6copH &ompOLDQcH0HWKoG /3$&DOcXODWLoQ $GMXVWmHQW &ompOLDQcH 9HULfLcDWLoQ $OWHUDWLRQ ([WHULRU/LJKWLQJOHVVWKDQUHSODFHG 1RWDSSOLFDEOHWRH[WHULRU&203/,(6 $GGLWLoQDO(QHUJ\ (ffLcLHQc\ $(& 0HDVXUHV,QcOXGHG 1ROLJKWLQJRUHOHFWULFDODGGLWLRQDOHQHUJ\HIILFLHQF\ PHDVXUHVLQFOXGHGLQSURMHFW/oDG0DQDJHmHQW /'0 0HDVXUHV,QcOXGHG 1ROLJKWLQJRUHOHFWULFDOORDGPDQDJHPHQWPHDVXUHVLQFOXGHGLQSURMHFW 3UoMHcW7LWOH5HQWoQ3LD]]D:6(&'DWH'Hc /LJKWLQJ3owHU&DOcXODWLoQ$/7(5$7,21(;7(5,25/,*+7,1* OHVVWKDQUHpODcHG &ompOLDQcH9HULfLcDWLoQ&203/,(6 ([WHULoU/LJKWLQJ3owHU$OOowDQcH &DWHJoU\([LVWLQJ/LJKWLQJ:DWWDJH 3ULoUWo$OWHUDWLoQ 7oWDO:DWWV$OOowHG 3UopoVHG7oWDO/3'&ompOLDQcH6WDWXV ([LVWLQJ/LJKWLQJ &203/,(6 3UopoVHG([WHULoU/LJKWLQJ3owHU'HQVLW\ )L[WXUH7\pH )L[WXUH,'1HwoU([LVWLQJWo5HmDLQ 4XDQWLW\of )L[WXUHV &/'VoU /XmLQDLUHV ) :DWWVpHU )L[WXUH&/'oU /XmLQDLUH :p) 7oWDO/LQHDU )HHW /) :DWWVpHU/LQHDU )ooW :p/) 7oWDO:DWWV 3UopoVHG )[:p) oU /)[:p/) ,QGLYLGXDO)L[WXUHV &DWHQDU\)1HZ  /DQGVFDSH&([LVWLQJWRUHPDLQ  3ROHPRXQWHG$([LVWLQJWRUHPDLQ  3ROHPRXQWHG$([LVWLQJWRUHPDLQ  3ROHPRXQWHG)$1HZ  3ROHPRXQWHG)1HZ  3UoMHcW7LWOH5HQWoQ3LD]]D:6(&'DWH'Hc 3UopoVHG)L[WXUHV'HWDLOV$/7(5$7,21(;7(5,25/,*+7,1* OHVVWKDQUHpODcHG )L[WXUH7\pH$ppOLcDWLoQ)L[WXUH,'/ocDWLoQLQ'ocXmHQWV/Dmp7\pH 1HwoU([LVWLQJWo5HmDLQ ,QGLYLGXDO)L[WXUHV &DWHQDU\)(/('1HZ   30 ZDHQHUJ\FRGHVFRPSULQWBSURMHFWBVXPPDU\BIRUPSKS"N YWYPIG*=;%3:[=]YZ=9X=;GI=;K=;-SEIONNZ=FKE+ROFPFD:X;[;]8Z-QRPGMVG*GIFNYF« KWWSVZZZZDHQHUJ\FRGHVFRPSULQWBSURMHFWBVXPPDU\BIRUPSKS"N YWYPIG*=;%3:[=]YZ=9X=;GI=;K=;-SEIONNZ=FKE+ROFPFD:X;[;]8Z-QRPGMVG*GIFNYF*9IEP«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« KWWSVZZZZDHQHUJ\FRGHVFRPSULQWBSURMHFWBVXPPDU\BIRUPSKS"N YWYPIG*=;%3:[=]YZ=9X=;GI=;K=;-SEIONNZ=FKE+ROFPFD:X;[;]8Z-QRPGMVG*GIFNYF*9IEP« DEVELOPMENT ENGINEERING msippo 08/13/2025 T-433404 BU R N E T T A V E S WELLS AVE S BU R N E T T P L S MILL AVE S N RIVERSIDE DR MAIN AVE S S 2ND ST S 2ND ST N 1ST ST CEDAR AVE S WIL L I A M S A V E S BURNETT AVE S SHATTUCK AVE S MORRIS AVE S S 3RD ST MORRIS AVE S S 3RD ST S TOBIN ST WE L L S A V E S SH A T T U C K A V E S S 4TH ST MO R R I S A V E S SH A T T U C K A V E S BURNETT AVE S S 3RD PL MIL L A V E S HOUSER WAY SWILLIAMS AVE S S 4TH ST HOUSER WAY S LOGAN AVE S S 3RD ST S 2ND ST BURNETT AVE S S 2ND ST BURNETT AVE S S 3RD ST S 2ND ST N RIVERSIDE DR S TOBIN ST S 4TH ST SM I T H E R S A V E S WILLIAMS AVE S S 3RD ST PELLY AVE N MAIN AVE S S 4TH ST WILLIAMS AVE S HOUSER WAY S LO G A N A V E S MILL AVE S WHITWORTH AVE S MAIN AVE S WELLS AVE S S 4TH ST BRONSON WAY N S 3RD ST S 4TH ST MA I N A V E S WILLIAMS AVE S S 4TH ST S 3RD ST S 3RD ST WHITWORTH AVE S SMITHERS AVE S WELLS AVE S WH I T W O R T H A V E S S 2ND ST HOUSER W A Y S WILLIAMS AVE S S 2ND ST LOGAN AVE S S 2ND ST MAIN AVE S S 2ND ST HOUSER WAY S S TOBIN STS TOBIN ST MORRIS AVE S WELLS AVE S WELLS AVE S N 1ST ST SHATTUCK AVE S S 4TH PL HOUSER WAY S HOUSER WAY S SHATTUCK AVE S BRONSON WAY N MAIN AVE S S 3RD ST S 3RD ST BRONSON WAY N S 2ND STS 2ND ST S 2ND ST SMITHERS AVE S S 2ND ST S 2ND ST I-405 FWY PROJECT LOCATION Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 VICINITY MAP 1" = 500'±RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT COVER R-433401 1 61 7 / 16 / 2025 TR O - 4 1 - 4 3 3 4 61 1/16"=1'-0" ED1.00 T-433410 ELECTRICAL - DEMO SITE PLAN - PIAZZA 56 ϭϲϬϭ ϱƚŚ ǀĞŶƵĞ͕ ^ƵŝƚĞ ϭϲϬϬ ^ĞĂƚƚůĞ͕ t ϵϴϭϬϭ ϮϬϲ͘ϲϮϮ͘ϱϴϮϮ ZZZNSIIFRP Arup US, Inc. 1191 Second Avenue Suite 400 Seattle WA 98101 T +1 206 493 2258 F + 1 206 749 0665 DEMO EXISTING LIGHT & POLE, RETAIN 3/4" CONDUIT TO EXTEND TO NEW MAST LIGHT POLES IN THIS AREA. DEMO EXISTING LIGHT & POLE, RETAIN 3/4" CONDUIT TO EXTEND TO NEW MAST LIGHT POLE IN THIS AREA. DEMO EXISTING RECEPTACLES (TYP) DEMO EXISTING LIGHT FIXTURES & POLES (TYP) DEMO EXISTING RECEPTACLE ENCLOSURE. RETAIN (3) EXISTING CONDUITS TO EXTEND TO NEW RECEPTACLE ENCLOSURE. DEMO EXISTING RECEPTACLE, RETAIN 3/4" CONDUIT TO EXTEND TO NEW RECEPTACLE AT BASE OF MAST LIGHT POLE FIXTURE. SITE POWER PANELBOARDS (E) E1 AND (E) E2 SHALL REMAIN AS EXISTING (E) E1 (E) E2 (E) DEMO EXISTING LIGHT & POLE, RETAIN 3/4" CONDUIT TO EXTEND TO NEW MAST LIGHT POLE IN THIS AREA. DEMO EXISTING LIGHT FIXTURE & POLE (TYP) DEMO EXISTING WATER FEATURE LIGHTS KEYED NOTES RETAIN EXISTING CONDUIT TO EXTEND TO NEW RECEPTACLE LOCATION SHOWN ON SHEET E1.00P. COORDINATE EXACT LOCATION WITH LANDSCAPE ARCHITECT. EXISTING WATER FEATURE, INCLUDING FOUNTAIN PUMP AND FOUNTAIN LIGHTS, TO BE DEMOLISHED. 1 DEMO EXISTING LINEAR TUBE LIGHT FIXTURE, TYPE C DEMO EXISTING DIRECT BURIAL LIGHT FIXTURE, TYPE B (TYP) 1 1 2 1 1 1 2 2 REFERENCE MARKET DRAWINGS FOR LIGHTING AND POWER WITHIN THE BUILDING. SHEET NOTES A. DEMOLITION NOTES FOR INTERIOR BUILDING SPACES NOT INCLUDED ON THIS SHEET. REFERENCE MARKET SHEETS E2.00 AND E3.00 SERIES FOR INTERIOR BUILDING DEMOLITION NOTES. DEVELOPMENT ENGINEERING msippo 08/13/2025 T-433405 BU R N E T T A V E S WELLS AVE S BU R N E T T P L S MILL AVE S N RIVERSIDE DR MAIN AVE S S 2ND ST S 2ND ST N 1ST ST CEDAR AVE S WIL L I A M S A V E S BURNETT AVE S SHATTUCK AVE S MORRIS AVE S S 3RD ST MORRIS AVE S S 3RD ST S TOBIN ST WE L L S A V E S SH A T T U C K A V E S S 4TH ST MO R R I S A V E S SH A T T U C K A V E S BURNETT AVE S S 3RD PL MIL L A V E S HOUSER WAY SWILLIAMS AVE S S 4TH ST HOUSER WAY S LOGAN AVE S S 3RD ST S 2ND ST BURNETT AVE S S 2ND ST BURNETT AVE S S 3RD ST S 2ND ST N RIVERSIDE DR S TOBIN ST S 4TH ST SM I T H E R S A V E S WILLIAMS AVE S S 3RD ST PELLY AVE N MAIN AVE S S 4TH ST WILLIAMS AVE S HOUSER WAY S LO G A N A V E S MILL AVE S WHITWORTH AVE S MAIN AVE S WELLS AVE S S 4TH ST BRONSON WAY N S 3RD ST S 4TH ST MA I N A V E S WILLIAMS AVE S S 4TH ST S 3RD ST S 3RD ST WHITWORTH AVE S SMITHERS AVE S WELLS AVE S WH I T W O R T H A V E S S 2ND ST HOUSER W A Y S WILLIAMS AVE S S 2ND ST LOGAN AVE S S 2ND ST MAIN AVE S S 2ND ST HOUSER WAY S S TOBIN STS TOBIN ST MORRIS AVE S WELLS AVE S WELLS AVE S N 1ST ST SHATTUCK AVE S S 4TH PL HOUSER WAY S HOUSER WAY S SHATTUCK AVE S BRONSON WAY N MAIN AVE S S 3RD ST S 3RD ST BRONSON WAY N S 2ND STS 2ND ST S 2ND ST SMITHERS AVE S S 2ND ST S 2ND ST I-405 FWY PROJECT LOCATION Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 VICINITY MAP 1" = 500'±RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT COVER R-433401 1 61 7 / 16 / 2025 TR O - 4 1 - 4 3 3 4 61 1"=25'-0" T-433411 ELECTRICAL - SITE POWER PLAN - PIAZZA 57 E1.00P 62 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com ϭϲϬϭ ϱƚŚ ǀĞŶƵĞ͕ ^ƵŝƚĞ ϭϲϬϬ ^ĞĂƚƚůĞ͕ t ϵϴϭϬϭ ϮϬϲ͘ϲϮϮ͘ϱϴϮϮ ZZZNSIIFRP Arup US, Inc. 1191 Second Avenue Suite 400 Seattle WA 98101 T +1 206 493 2258 F + 1 206 749 0665 DECK4.OUTDOOR.TABLES DECK4.OUTDOOR.TABLES BU R N E T T A V E S . LO G A N A V E S . 004ASI-002 004ASI-002 004ASI-002 004ASI-002 004ASI-002 1 1 1 1 1 DEVELOPMENT ENGINEERING msippo 10/02/2025 BU R N E T T A V E S WELLS AVE S BU R N E T T P L S MILL AVE S N RIVERSIDE DR MAIN AVE S S 2ND ST S 2ND ST N 1ST ST CEDAR AVE S WIL L I A M S A V E S BURNETT AVE S SHATTUCK AVE S MORRIS AVE S S 3RD ST MORRIS AVE S S 3RD ST S TOBIN ST WE L L S A V E S SH A T T U C K A V E S S 4TH ST MO R R I S A V E S SH A T T U C K A V E S BURNETT AVE S S 3RD PL MIL L A V E S HOUSER WAY SWILLIAMS AVE S S 4TH ST HOUSER WAY S LOGAN AVE S S 3RD ST S 2ND ST BURNETT AVE S S 2ND ST BURNETT AVE S S 3RD ST S 2ND ST N RIVERSIDE DR S TOBIN ST S 4TH ST SM I T H E R S A V E S WILLIAMS AVE S S 3RD ST PELLY AVE N MAIN AVE S S 4TH ST WILLIAMS AVE S HOUSER WAY S LO G A N A V E S MILL AVE S WHITWORTH AVE S MAIN AVE S WELLS AVE S S 4TH ST BRONSON WAY N S 3RD ST S 4TH ST MA I N A V E S WILLIAMS AVE S S 4TH ST S 3RD ST S 3RD ST WHITWORTH AVE S SMITHERS AVE S WELLS AVE S WH I T W O R T H A V E S S 2ND ST HOUSER W A Y S WILLIAMS AVE S S 2ND ST LOGAN AVE S S 2ND ST MAIN AVE S S 2ND ST HOUSER WAY S S TOBIN STS TOBIN ST MORRIS AVE S WELLS AVE S WELLS AVE S N 1ST ST SHATTUCK AVE S S 4TH PL HOUSER WAY S HOUSER WAY S SHATTUCK AVE S BRONSON WAY N MAIN AVE S S 3RD ST S 3RD ST BRONSON WAY N S 2ND STS 2ND ST S 2ND ST SMITHERS AVE S S 2ND ST S 2ND ST I-405 FWY PROJECT LOCATION Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 VICINITY MAP 1" = 500'±RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT COVER R-433401 1 61 7 / 16 / 2025 TR O - 4 1 - 4 3 3 4 61 AS NOTED E5.01 T-433412 58 ELECTRICAL - SINGLE LINE DIAGRAM ϭϲϬϭ ϱƚŚ ǀĞŶƵĞ͕ ^ƵŝƚĞ ϭϲϬϬ ^ĞĂƚƚůĞ͕ t ϵϴϭϬϭ ϮϬϲ͘ϲϮϮ͘ϱϴϮϮ ZZZNSIIFRP Arup US, Inc. 1191 Second Avenue Suite 400 Seattle WA 98101 T +1 206 493 2258 F + 1 206 749 0665 BU R N E T T A V E S BU R N E T T P L S WIL L I A M S A V E S S TOBIN ST WE L L S A V E S SH A T T U C K A V E S MO R R I S A V E S SH A T T U C K A LO G A N A V E S MA I N A V E S WH I T W O R T H A V E S HOUSER W A Y S S TOBIN ST S 3RD ST S 2ND ST PROJECT LOCATION AD AREA DRAIN AVE AVENUE CB CATCH BASIN CL CENTER LINE COR CITY OF RENTON CSBC CRUSHED SURFACE BASE COURSE DEMO DEMOLISH ELECT ELECTRICAL ELELEV ELEVATION E;E;ISTE;ISTING GI GREASE INTERCEPTOR HMA HOT MI; ASPHALT IE INVERT ELEVATION LF LINEAR FOOT LS LANDSCAPELANDSCAPING MA;MA;IMUM MIN MINIMUM NTS NOT TO SCALE PLUMB PLUMBING ROW RIGHT OF WAY SD STORE DRAIN SS SANITARY SEWER STD STANDARD TYP TYPICAL W WATER NUMBER 9,C,1,7< 0$3 1" = 500'± RENTON PIA==A CI9IL CONSTR8CTION PERMIT $%%5(9,$7,216 (E) SERVICE 1 TRANSFORMER FROM UTILITY SHEET NOTES A. HALFTONE DENOTES EXISTING TO REMAIN EQUIPMENT. B. HATCHED AREAS DENOTE EQUIPMENT SERVING THE MARKET BUILDING, AND IS OUT OF SCOPE FOR THE PIAZZA PROJECT. ELECTRICAL EQUIPMENT NAMING CONVENTION (N)A1 INDEX 1, 2, 3, ... ADDITIONAL INDEX SPECIAL LOAD DESCRIPTION A ANCHOR TENANT L LIGHTING M MECHANICAL P NORMAL POWER T TENANT PHASE (E)EXISTING (N)NEW (4) 600KCMIL +#2G IN 4"C DEVELOPMENT ENGINEERING msippo 08/13/2025 T-433407 BU R N E T T A V E S WELLS AVE S BU R N E T T P L S MILL AVE S N RIVERSIDE DR MAIN AVE S S 2ND ST S 2ND ST N 1ST ST CEDAR AVE S WIL L I A M S A V E S BURNETT AVE S SHATTUCK AVE S MORRIS AVE S S 3RD ST MORRIS AVE S S 3RD ST S TOBIN ST WE L L S A V E S SH A T T U C K A V E S S 4TH ST MO R R I S A V E S SH A T T U C K A V E S BURNETT AVE S S 3RD PL MIL L A V E S HOUSER WAY SWILLIAMS AVE S S 4TH ST HOUSER WAY S LOGAN AVE S S 3RD ST S 2ND ST BURNETT AVE S S 2ND ST BURNETT AVE S S 3RD ST S 2ND ST N RIVERSIDE DR S TOBIN ST S 4TH ST SM I T H E R S A V E S WILLIAMS AVE S S 3RD ST PELLY AVE N MAIN AVE S S 4TH ST WILLIAMS AVE S HOUSER WAY S LO G A N A V E S MILL AVE S WHITWORTH AVE S MAIN AVE S WELLS AVE S S 4TH ST BRONSON WAY N S 3RD ST S 4TH ST MA I N A V E S WILLIAMS AVE S S 4TH ST S 3RD ST S 3RD ST WHITWORTH AVE S SMITHERS AVE S WELLS AVE S WH I T W O R T H A V E S S 2ND ST HOUSER W A Y S WILLIAMS AVE S S 2ND ST LOGAN AVE S S 2ND ST MAIN AVE S S 2ND ST HOUSER WAY S S TOBIN STS TOBIN ST MORRIS AVE S WELLS AVE S WELLS AVE S N 1ST ST SHATTUCK AVE S S 4TH PL HOUSER WAY S HOUSER WAY S SHATTUCK AVE S BRONSON WAY N MAIN AVE S S 3RD ST S 3RD ST BRONSON WAY N S 2ND STS 2ND ST S 2ND ST SMITHERS AVE S S 2ND ST S 2ND ST I-405 FWY PROJECT LOCATION Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 VICINITY MAP 1" = 500'±RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT COVER R-433401 1 61 7 / 16 / 2025 TR O - 4 1 - 4 3 3 4 61 NTS E7.02 T-433413 ELECTRICAL - ELECTRICAL DETAILS - PIAZZA 59 62 1 CIVIL PERMIT CORRECTIONS 1 9/15/2025 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com ϭϲϬϭ ϱƚŚ ǀĞŶƵĞ͕ ^ƵŝƚĞ ϭϲϬϬ ^ĞĂƚƚůĞ͕ t ϵϴϭϬϭ ϮϬϲ͘ϲϮϮ͘ϱϴϮϮ ZZZNSIIFRP Arup US, Inc. 1191 Second Avenue Suite 400 Seattle WA 98101 T +1 206 493 2258 F + 1 206 749 0665 SHATTUCK AVE S MOR MO S SH A T T U C K A V E S S 4TH ST SH A T T U C K A V E S S 3RD PL S 2ND ST S TOBIN ST WHITWORTH AVE S S 4TH ST S 3RD ST WHITWORTH AVE S WH I T W O R T H A V E S S 2ND ST S 2ND ST HOUSER WAY SMOR SHATTUCK AVE S S 4TH PL SHATTUCK AVE S S 3RD ST PRO LOC IN COMPLIAN RENTON MARKET & PIA CIVIL CONSTRUCTION PERMIT 1 SHATTUCK AVE S MOR MO S SH A T T U C K A V E S S 4TH ST SH A T T U C K A V E S S 3RD PL S 2ND ST S TOBIN ST WHITWORTH AVE S S 4TH ST S 3RD ST WHITWORTH AVE S WH I T W O R T H A V E S S 2ND ST S 2ND ST HOUSER WAY SMOR SHATTUCK AVE S S 4TH PL SHATTUCK AVE S S 3RD ST PRO LOC IN COMPLIAN RENTON MARKET & PIA CIVIL CONSTRUCTION PERMIT 1 䑯捵卩杮 䕮癥汯灥 䥄㨠 刯 䑯捵卩杮 䕮癥汯灥 䥄㨠 ㄯ 1 DEVELOPMENT ENGINEERING msippo 10/02/2025 BU R N E T T A V E S WELLS AVE S BU R N E T T P L S MILL AVE S N RIVERSIDE DR MAIN AVE S S 2ND ST S 2ND ST N 1ST ST CEDAR AVE S WIL L I A M S A V E S BURNETT AVE S SHATTUCK AVE S MORRIS AVE S S 3RD ST MORRIS AVE S S 3RD ST S TOBIN ST WE L L S A V E S SH A T T U C K A V E S S 4TH ST MO R R I S A V E S SH A T T U C K A V E S BURNETT AVE S S 3RD PL MIL L A V E S HOUSER WAY SWILLIAMS AVE S S 4TH ST HOUSER WAY S LOGAN AVE S S 3RD ST S 2ND ST BURNETT AVE S S 2ND ST BURNETT AVE S S 3RD ST S 2ND ST N RIVERSIDE DR S TOBIN ST S 4TH ST SM I T H E R S A V E S WILLIAMS AVE S S 3RD ST PELLY AVE N MAIN AVE S S 4TH ST WILLIAMS AVE S HOUSER WAY S LO G A N A V E S MILL AVE S WHITWORTH AVE S MAIN AVE S WELLS AVE S S 4TH ST BRONSON WAY N S 3RD ST S 4TH ST MA I N A V E S WILLIAMS AVE S S 4TH ST S 3RD ST S 3RD ST WHITWORTH AVE S SMITHERS AVE S WELLS AVE S WH I T W O R T H A V E S S 2ND ST HOUSER W A Y S WILLIAMS AVE S S 2ND ST LOGAN AVE S S 2ND ST MAIN AVE S S 2ND ST HOUSER WAY S S TOBIN STS TOBIN ST MORRIS AVE S WELLS AVE S WELLS AVE S N 1ST ST SHATTUCK AVE S S 4TH PL HOUSER WAY S HOUSER WAY S SHATTUCK AVE S BRONSON WAY N MAIN AVE S S 3RD ST S 3RD ST BRONSON WAY N S 2ND STS 2ND ST S 2ND ST SMITHERS AVE S S 2ND ST S 2ND ST I-405 FWY PROJECT LOCATION Call 811 two business days before you dig R 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 VICINITY MAP 1" = 500'±RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT COVER R-433401 1 61 7 / 16 / 2025 TR O - 4 1 - 4 3 3 4 61 NTS E9.05 T-433413 ELECTRICAL - PANELBOARD SCHEDULES 59 ϭϲϬϭ ϱƚŚ ǀĞŶƵĞ͕ ^ƵŝƚĞ ϭϲϬϬ ^ĞĂƚƚůĞ͕ t ϵϴϭϬϭ ϮϬϲ͘ϲϮϮ͘ϱϴϮϮ ZZZNSIIFRP Arup US, Inc. 1191 Second Avenue Suite 400 Seattle WA 98101 T +1 206 493 2258 F + 1 206 749 0665 PANEL:(E) E2 SHEET NO:E9.05 DESCRIPTION:PIAZZA RECEPT LOCATION:ELECTRICAL ROOM 111 VOLTS:240/120 V SUPPLY FROM:PANEL (E) E1 MOUNTING:SURFACE PHASE:1 BUS RATING:600A ENCLOSURE:Type 1 WIRE:3 MAINS TYPE:MLO A.I.C. RATING 22 kA GROUND BUS:BONDED MAINS RATING:- NEUTRAL BUS:100%LUGS: CKT CIRCUIT DESCRIPTION LC TRIP P P TRIP LC CIRCUIT DESCRIPTION CKT 1 0 0 2 3 0 0 4 5 0 0 6 7 0 0 8 9 0 0 10 11 0 0 12 13 4800 0 14 15 4800 0 16 17 (E) RCPT BANK #1 [1]Existing 20 1 0 0 1 20 Existing (E) RCPT BANK #2 [1]18 19 (E) RCPT BANK #1 [1]Existing 20 1 0 0 1 20 Existing (E) RCPT BANK #2 [1]20 21 (E) RCPT BANK #3 [1]Existing 20 1 0 360 1 20 Receptacle RCPT - STAGE VAULT 22 23 (E) RCPT BANK #3 [1]Existing 20 1 0 0 1 20 -SPARE 24 25 Space - 20 1 1 20 -Space 26 27 Space - 20 1 1 20 -Space 28 29 Space - - - 1 20 -Space 30 CONNECTED: 15,744 VA CALCULATED DEMAND: 17,190 VA CONNECTED: 66 A CALCULATED DEMAND: 72 A NOTES: [1] CIRCUITS USING THE CLASSIFICATION "EXISTING" ARE EXISTING TO REMAIN. THE LOAD FOR THESE CIRCUITS WAS CAPTURED BY 30-DAY METERING DATA COLLECTED FROM 11/27/2024 TO 12/27/2024 WITH THE PEAK 30-DAY LOAD SHOWN AS THE CONNECTED LOAD AT THE BOTTOM OF THE PANELBOARD SCHEDULE, PER NEC 220.87. Receptacle 9960 VA 100.00%9960 VA Existing 5784 VA 125.00%7230 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR CALCULATED DEMAND PANEL TOTALS LOADS TOTAL LOAD:5160 VA 4800 VA TOTAL AMPS:43 A 40 A Existing (E) RCPT BANK #3 [1] RCPT- STAGE VAULT Receptacle 50 2 2 30 - (E) SPARE (E) RCPT BANK #3 [1] Existing 50 2 2 30 Existing (E) RCPT BANK #1 [1] (E) RCPT BANK #2 [1] Existing 50 2 2 30 Existing (E) RCPT BANK #2 [1] (E) RCPT BANK #1 [1] Existing 50 2 2 30 A B DEVELOPMENT ENGINEERING msippo 08/13/2025 T-433408 BU R N E T T A V E S • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • LO G A N A V E S • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Call 811 two business days before you dig R CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT TOPOGRAPHIC SURVEY PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 R-433423 P S O M A S Tacoma 2502 Jefferson Avenue Tacoma, WA 98402 253.627.0720 Seattle | Wenatchee PLAN 07/15/2025 DEVELOPMENT ENGINEERING msippo 08/13/2025 R-433452 •••••••••••••••• •••••••••••• NOTES HORIZONTAL DATUM VERTICAL DATUM Call 811 two business days before you dig R CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT TOPOGRAPHIC SURVEY PR 2 4 - 0 0 0 0 8 2 LU A 2 4 - 0 0 0 3 6 4 C2 5 0 0 0 2 3 3 TE D - 4 0 - 4 3 3 4 R-433423 P S O M A S Tacoma 2502 Jefferson Avenue Tacoma, WA 98402 253.627.0720 Seattle | Wenatchee 07/15/2025 DEVELOPMENT ENGINEERING msippo 08/13/2025 R-433453