Loading...
HomeMy WebLinkAboutR-435401r) U) It N I 2 U al U) LL- QI LL ry �I m U) LL- LL o' 0 c m ry N N U 0 r) _Y to a> 0 Q FIRE STATION 16 AND MAINTENANCE BLDG RENTON REGIONAL FIRE AUTHORITY RENTON, WA GENERAL PROJECT NOTES 1. CONSTRUCTION OF THIS PROJECT SHALL BE IN COMPLIANCE WITH ALL APPLICABLE CODES, ORDINANCES AND REGULATIONS. 2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND EACH SUBCONTRACTOR TO REVIEW, UNDERSTAND AND COORDINATE WORK WITH APPLICABLE CODES, ORDINANCES, REGULATIONS, AND ALL CONTRACT DRAWINGS BEFORE THE INSTALLATION OF THEIR WORK. ANY DISCREPANCY BETWEEN DRAWINGS AND SPECIFICATIONS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DOCUMENTS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS OWN EXPENSE AND AT NO EXPENSE TO THE OWNER, ENGINEER OR ARCHITECT. 3. SCHEDULE AND RECEIVE APPROVAL FROM GOVERNING JURISDICTION AND THE ENGINEER FOR ALL UTILITY INTERRUPTIONS IN ADVANCE OF NEEDED DATE. CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE REQUIRED NOTIFICATION TIMES WITH EACH GOVERNING JURISDICTION AND/OR UTILITY. 4. CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL EQUIPMENT, ELECTRICAL EQUIPMENT, OWNER SUPPLIED EQUIPMENT, AND OTHER EQUIPMENT, AS WELL AS SHOP DRAWINGS AS REVIEWED BY ARCHITECT OR ENGINEER BEFORE PROCEEDING WITH WORK. 5. CONTRACTOR SHALL VERIFY/ADJUST SIZES AND LOCATIONS OF ALL EQUIPMENT PADS AND BASES, POWER, WATER AND DRAIN INSTALLATION BEFORE PROCEEDING WITH THE WORK. THIS SHALL OCCUR WITH NO ADDITIONAL COST TO OWNER. 6. PROVIDE BLOCKING BEHIND ALL WALL MOUNTED ACCESSORIES AND MILLWORK AS REQUIRED BY APPLICABLE MANUFACTURER RECOMMENDATIONS, AND AS INDICATED BY ARCHITECT DURING SUBMITTAL PROCESS. 7. ALL PENETRATIONS OF FIRE RESISTIVE WALLS SHALL BE PROTECTED BY MATERIALS AND INSTALLATION DETAILS THAT CONFORM TO UNDERWRITERS LABORATORIES' LISTINGS FOR THROUGH PENETRATION FIRE STOP SYSTEM. 8. CONTRACTOR SHALL CONTACT ARCHITECT PRIOR TO FINAL PLACEMENT OF LIGHT FIXTURES AND DIFFUSERS IN ALL CEILINGS AND WALLS. COORDINATE WITH ELECTRICAL PRIOR TO ACOUSTICAL CEILING GRID INSTALLATION. 9. ALL DIMENSIONS ARE FROM FACE OF CONCRETE MASONRY UNIT, BLOCK, STUD OR CENTERLINE OF COLUMNS, UNLESS NOTED OTHERWISE. 10. ALL EXTERIOR WALL & ROOF OPENINGS, FLASHING, COUNTER -FLASHING, EXPANSION JOINTS SHALL BE CONSTRUCTED IN SUCH A MANNER AS TO MAKE THEM WEATHERPROOF AND WATERTIGHT. 11. EACH INSTALLER SHALL BE RESPONSIBLE FOR VERIFICATION AND COORDINATION WITH OTHER INSTALLERS TO SECURE COMPLIANCE OF DRAWING AND SPECIFICATIONS CONCERNING THE ACCURATE LOCATION OF STRUCTURAL MEMBERS AND OPENINGS FOR MECHANICAL, ELECTRICAL AND MISCELLANEOUS EQUIPMENT. 12. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS AS SHOWN AND ACTUAL FIELD MEASUREMENT. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 13. RECYCLING- CONTRACTOR IS ENCOURAGED TO RECYCLE ALL MATERIALS POSSIBLE AND TO USE RECYCLED MATERIALS WHERE SUITABLE. CONTRACTOR SHOULD NOTIFY ARCHITECT OF POTENTIAL RECYCLED MATERIALS WHICH MAY BE APPROPRIATE FOR SUBSTITUTION. REFER TO THE'DIRECTORY OF RECYCLED CONTENT BUILDING AND CONSTRUCTION PRODUCTS', CLEAN WASHINGTON CENTER, (206) 464-7040. 14. THIS PROJECT HAS UNIT COSTS, SEE SPECIFICATIONS. 15. THIS PROJECT HAS BIDDER DESIGNED AND INSTALLED FEATURES AS NOTED BELOW, TO BE SUBMITTED AS A DEFERRED SUBMITTAL BY THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR APPLYING FOR AND OBTAINING ALL REQUIRED PERMITS. THE CONTRACTOR IS RESPONSIBLE FOR INCLUDING ALL PREPARATION AND PERMIT REVIEW TIME IN THE PROJECT SCHEDULE. THE CONTRACTOR SHALL HIRE ENGINEERS FOR DELEGATED DESIGN AND PROVIDE REQUIRED STAMPED (BY WA STATE LICENSED ENGINEERS) DRAWINGS AND CALCULATIONS. BIDDER DESIGNED & INSTALLED ITEMS INCLUDE: • AUTO. SPRINKLER SYSTEM PER NFPA 13, IBC SECTION 903.3.1.1 • FIRE ALARM SYSTEM PER SPECIFICATIONS AND REQUIREMENTS • METAL SHELVING SEISMIC ATTACHMENT. • STEEL STAIRS AND RAILINGS PER SPECIFICATIONS AND REQUIREMENTS • PHOTOVOLTAIC SYSTEMS • SOILS IMPROVEMENTS DESIGN AND SYSTEMS • FALL PROTECTION SYSTEMS • ALL DEFERRED SUBMITTALS AS LISTED ON DRAWINGS AND SPECIFICATIONS 16. SYSTEMS COMMISSIONING - • IDENTIFICATION MARK SHALL BE APPLIED TO ALL INSULATION MATERIALS AND INSULATION INSTALLED SUCH THAT THE MARK IS READILY OBSERVABLE DURING INSPECTION. • ALL HVAC CONTROL SYSTEMS AND OTHER AUTOMATICALLY CONTROLLED SYSTEMS FOR WHICH ENERGY CONSUMPTION PERFORMANCE, OR MODE OF OPERATION ARE REGULATED BY WAC.51-11-1416 SHALL REQUIRE SYSTEMS COMMISSIONING. PRELIMINARY AND FINAL REPORTS SHALL BE IN ACCORDANCE WITH SECTION 1416.4.2.2 • CLOSEOUT DOCUMENTATION SHALL INCLUDE APPLICABLE WSEC ENVELOPE COMPLIANCE FORMS AND CALCULATIONS, AND FENESTRATION NFRC RATING CERTIFICATES 17. PROVIDE FIRE BLOCKING PER 2021 IBC SECTION 718 18. PROVIDE A 2021 WASHINGTON STATE ENERGY CODE (WSEC) COMPLIANT AIR BARRIER INCLUDING BLOWER DOOR TESTING, INSPECTIONS, SEALING AND REPORTS. 19. REFER TO SPECIFICATION SECTION 00 7700 FOR CLOSEOUT PROCEDURES COMPLIANT WITH WSEC C103.6 DRAWING SYMBOLS VICINITY MAP ay cfk[ok Pork 7 LANGL€x MIDGE _DU . MAY CREEK a m IiI.LAN D MOBILE MANO R EPSURF ESTATES z x z m j ERI{: HO ESTATES 2 � c z ASTER ii,Art f � �:04LI�IEL� SE %P Ian a East Renton Highlands PROJECT SITE Maplewood Park MAP LEWOO D -w: HMGH 1 ti SE T A4th St peV MAPLE HILL: Cedar Gfoye Park 5d4 Maple Heights - Lake Desire id4 RENTON PARK I•ai1lrwd ABBREVIATIONS PROJECT INFORMATION PERMIT NUMBER: #PRE22-000062 SITE ADDRESS: FIRE STATION: 15821 SE 128TH ST 98059 MAINT. BLDG: 12930158TH AVE SE 98059 ZONING: R4 LOT AREA: SITE NORTH: 66,425 SF SITE SOUTH: 81,643 SF ALLEY AREA: 3,647 SF TOTAL LOT AREA: 151,721 SF (3.4 ACRE) ALLOWABLE BUILDING AREA: 35% OR 53,100 SF (FOR COMBINED LOT) BUILDING AREA: FIRE STATION MAINT. BUILDING BUILDING FOOTPRINT: 13,024 SF 9,886 SF CANOPIES: 1,136 SF 0 SF FUTURE ADDITION: 0 SF 1,362 SF SUBTOTAL AREA: 14,160 SF 11,248 SF TOTAL AREA: 25,408 SF OR 16.7% ALLOWABLE IMPERVIOUS AREA: 50% OR 75,861 SF (FOR COMBINED LOT) ACTUAL IMPERVIOUS AREA: BUILDING AREA: 24,046 SF PAVEMENT: 48,285 SF FUTURE PAVEMENT: 1,072 SF TOTAL AREA: 74,765 SF OR 49.3% PROJECT DESCRIPTION: NEW FIRE STATION AND DEPARTMENTAL MAINTENANCE FACILITIES NOTES: 1. REFER TO STRUCTURAL SHEET FS-S1.1, MB-S1.1 AND PEMB DRAWING C1 FOR SEISMIC DESIGN CATEGORY AND DESIGN LOADS 2. REFER TO SHEET FS-T1.2 AND MB-T1.2 FOR CONSTRUCTION TYPES, OCCUPANCY GROUPS AND OCCUPANCY LOADS 3. REFER TO SHEETS FS-T1.3 AND MB-T1.3 FOR WSEC REQUIREMENTS PARCEL NUMBER AND LEGAL DESCRIPTION: • PARCEL A: (366450-0007) THE EAST 57 FEET OF THE WEST 291 FEET OF LOT 1, BLOCK 1, JANETT'S RENTON BOULEVARD TRACTS, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 17 OF PLATS, PAGE 60, RECORDS OF KING COUNTY, WASHINGTON. • PARCEL B: (366450-0008) THE EAST 171 FEET OF THE WEST 234 FEET OF LOT 1, BLOCK 1 AND LOTS 7, 8 AND 9, BLOCK 4, ALL IN JANETT'S RENTON BOULEVARD TRACTS, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 17 OF PLATS, PAGE 60, RECORDS OF KING COUNTY, WASHINGTON; EXCEPT THE NORTH 12 FEET OF SAID LOTS 7,8 AND 9 CONVEYED TO KING COUNTY FOR ROAD PURPOSES BY DEED RECORDED UNDER RECORDING NO. 5726494. • PARCEL C: (366450-0009) THE SOUTH 133 FEET OF THE WEST 63 FEET OF LOT 1, BLOCK 1, JANETT'S RENTON BOULEVARD TRACTS,ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 17 OF PLATS, PAGE 60, RECORDS OF KING COUNTY, WASHINGTON. SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. • PARCEL D: (366450-0330) LOT 6, BLOCK 4, IN JANETT'S RENTON BOULEVARD TRACTS, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 17 OF PLATS, PAGE 60, RECORDS OF KING COUNTY, WASHINGTON; ALL SITUATE IN THE NW QUARTER OF THE NE QUARTER OF SECTION 14, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M., KING COUNTY, WASHINGTON. & AND CLKG. CAULKING EQPT. / EQUIP. EQUIPMENT H.B. HOSE BIBB N. NORTH GRID LINE L ANGLE CLR. CLEAR E.W.C. ELECTRICAL WATER COOLER H.C. HOLLOW CORE N.I.C. NOT IN CONTRACT PREFERENCE @ AT CMU. CONCRETE MASONRY UNIT EX. / EXIST. EXISTING HD HEAD NO. NUMBER SIM % CENTERLINE CNTR. COUNTER EXPO. EXPOSED HDR. HEADER NOM. NOMINAL DETAIL REFERENCE DETAIL NUMBER GRID NUMBER QS DIAMETER \ 0 C.O. CASED OPENING OR CLEANOUT EXP. EXPANSION HDWD. HARDWOOD H N.T.S. NOT TO SCALE A101 A� SHEET NUMBER COL. COLUMN EXT. EXTERIOR HDWR. HARDWARE # POUND OR NUMBER ANCHOR BOLT BSIGN TYPE ACOUST. ACOUSTICAL A. . CONC. CONCRETE H.M. HOLLOW METAL O.A. OVERALL F.A. FIRE ALARM SIM F.B. FLAT BAR ROOM SIGNAGE TAG CONN. CONNECTION HORIZ. HORIZONTAL O.H. OVERHEAD 14JIASSOCIATED 1 SECTION NUMBER CONSTR. CONSTRUCTION HR. COHOUR OBS. OBSCURE BUILDING SECTION A.D. AREA DRAIN CONT. CONTINUOUS FCB FIBER COMPOSITE BOARD H.R. HANDRAIL O.C. ON CENTER OUTSIDE A#.# - SHEET NUMBER A.C. ASPHALT CONCRETE F.D. FLOOR DRAIN DOOR MARK CORP. CORRIDOR HSS HOLLOW STRUCTURAL SECTION O.D. DIAMETER (DIM.) O.D. ADJ. ADJACENT CPT. CARPET FDN. FOUNDATION HT. HEIGHT OF. OVERFLOW O.F. 711 ADJUST. ADJUSTABLE CRIBCRUSHED ROCK BASE F.E. FIRE EXTINGUISHER OFCI OWNER FURNISH/ NORTH ARROW A.F.F. ABOVE FINISH FLOOR F.E.C. FIRE EXTINGUISHER CABINET 1 -SECTION NUMBER CTR. CENTER I.B.C. INTERNATIONAL BUILDING CODE CONTRACTOR INSTALL WALL SECTION AGGR. AGGREGATE F. FINISH FLOOR A#.# SHEET NUMBER CTSK. COUNTERSUNK I.D. INSIDE DIAMETER (DIM.) OFF. OFFICE AHJ AUTHORITY HAVING JURISDICTION FG FIBER GLASS A.I.B. AIR INFILTRATION BARRIER IN. INCH OPNG. OPENING D.B. DOORBELL F.H. FIRE HYDRANT INCL. INCLUDE(D) OPP. OPPOSITE 1 AL/ALUM. ALUMINUM F.H.C. FIRE HOSE CABINET ELEVATION CASEWORK TAG . DBL. DOUBLE INSUL. INSULATION 0/ OVER (B.01.Ai CASEWORK TYPE APC ACOUSTICAL PANEL CEILING FIN. FINISH NUMBER DEPT. DEPARTMENT INT. INTERIOR 1 A7.1 1 REFERENCE APPROX. APPROXIMATE FL., FLR FLOOR INTERIOR ELEVATIONS DEMO. DEMOLISH, DEMOLITION PERP. PERPENDICULAR REFER TO A9.4 ARCH. ARCHITECTURAL OR ARCHITECT FLASH. FLASHING SHEET ASB. ASBESTOS D.F. DRINKING FOUNTAIN JAN. JANITOR PL. PLATE 1 DET./DTL. DETAIL FLUOR. FLUORESCENT JST. JOIST P-LAM, P. LAM. PLASTIC LAMINATE NUMBER WALL ASSEMBLY TAG ASPH. ASPHALT F.O.C. FACE OF CONCRETE WALL ASSEMBLY DIA. DIAMETER JT. JOINT PALST. PLASTER ROOM NAME $ 1 DIM. DIMENSION F.O.F. FACE OF FINISH PLYWD. PLYWOOD ROOM IDENTIFICATION INFORMATION BD. BOARD F.O.S. FACE OF STUDS 101 - ROOM REFER TO A5.1 & A9.1 BITUM. BITUMINOUS DISP DISPENSER F.P. FIREPLACE KIT. KITCHEN PNL. PANEL NUMBER BLDG. BUILDING DN. DOWN LAB. LABORATORY P.P. POWER POLE D.O. DOOR OPENING FPRF. FIREPROOF LAM. LAMINATE PR. PAIR WINDOW/RELITE TAG A > • WINDOW TYPE BILK. BLOCK DP DEEP FRP FIBERGLASS REINFORCED PANEL LAV. LAVATORY PRCST. PRECAST BLKG. BLOCKING DR. DOOR F.S. FULL SIZE LDRY. LAUNDRY PSL PARALLEL STRAND LUMBER REFERENCE BLW BELOW FT. FOOT OR FEET BM. BEAM D.S. DOWNSPOUT LKR. LOCKER P.T. PRESSURE TREATED DOOR TAG ### D.S.P DRY STANDPIPE FTG. FOOTING L.S. / LSCP LANDSCAPING PT. POINT DOOR TYPE BMK. BENCHMARK URR. FURRING D.W. DISHWASHER FLT. LIGHT PTD PAINTER REFERENCE BOT. BOTTOM FUT. FUTURE DWG. DRAWING PTD PAPER TOWEL DISPENSER BTWN. BETWEEN DWR. DRAWER F.V. FIELD VERIFY MAX. MAXIMUM PTD/R COMBINATION PAPER TOWEL KEYNOTE TAG N10.01 = KEYNOTE REFERENCE CAB. CABINET M.C. MEDICINE CABINET DISPENSER & RECEPTACLE C.B. CATCH BASIN E. EAST GA. GAUGE MECH. MECHANICAL PTN. PARTITION E.A. EXPOSED AGGREGATE GALV. GALVANIZED . MEMB. MEMBRANE P.T.A. PAPER TOWEL RECEPTACLE ROOFIFLOOR TAG R1 ROOPFLOOR ASSEMBLY CEM. CEMENT EA. EACH GB. GRAB BAR MFR. MANUFACTURE(R) PRE -FIN PRE -FINISHED CER. CERAMIC G.F.I. GROUND FAULT INTERRUPTER TYPE REFERENCE E.J. EXPANSION JOINT MH. MANHOLE C.F.M. CUBIC FEET/MIN. EL. ELEVATION GL. GLASS MIN. MINIMUM Q.T. QUARRY TILE C.G. CORNER GUARD CEILING TAG 10' 10" CEILING HEIGHT CH. CHALK ELEC. ELECTRICAL GLAM GLULAM MIR. MIRROR C.I. CAST IRON ELEV. ELEVATOR (OR ELEVATION) GND. GROUND MISC. MISCELLANEOUS R. RISER C.I.P. CAST IN PLACE EMER. EMERGENCY GR. GRADE M.O. MASONRY OPENING RAID. RADIUS ENCL. ENCLOSURE G.S. GALVANIZED STEEL MTD. MOUNTED METAL R.D. ROOF DRAIN C.J. CONSTRUCTION/CONTROL JOINT E.P. ELECTRICAL PANEL GWB GYPSUM WALL BOARD MTL. / MET. METAL RECP. RECEPTACLE C.L. CENTERLINE CLG. CEILING EQ. EQUAL GYP. GYPSUM MTR'L. MATERIAL RECEIPT. RECEPTION MUL. MULLION REF. REFERENCE PROJECT TEAM REFR. REFRIGERATOR REINF. REINFORCED REQ'D REQUIRED RESIL. RESILIENT RESIST. RESISTANT RM. ROOM R.O. ROUGH OPENING R. & S. ROD & SHELF RGSTR. REGISTER RSP RIGID SHEET PANEL WD. REDWOOD R.W.L. RAIN WATER LEADER OWNER: RENTON REGIONAL FIRE AUTHORITY 18002 108TH AVE SE RENTON, WA 98055 PHONE: 425.276.9503 CONTACT: DANIEL ALEXANDER ARCHITECT: TCA ARCHITECTURE PLANNING 6211 ROOSEVELT WAY NORTHEAST SEATTLE, WASHINGTON 98115 PHONE: 206.522.3830 CONTACT: MICHELLE LANGREHR CIVIL ENGINEER LPD ENGINEERS 1932 FIRST AVENUE, SUITE 500 SEATTLE, WA 98101 PHONE: 206.725.1211 CONTACT: MARC J. SERVIZI LANDSCAPE ARCHITECT AHBL 1200 6TH AVE, STE 1620 SEATTLE, WA 98101 PHONE: 253.383.2422 CONTACT: MEREDITH SESSIONS STRUCTURAL ENGINEER COUGHLIN PORTER LUNDEEN 1191 SECOND AVENUE, SUITE 1100 SEATTLE, WA 98101 PHONE: 206.343.0460 CONTACT: MIKE ARMSTRONG PEMB DESIGNER BAHNMILLER CONSTRUCTION 2811 ROCKEFELLER AVE EVERETT, WA 98201 PHONE: 949.244.8086 CONTACT: BRETT BONNER S. SOUTH SBC SEATTLE BUILDING CODE S.C. SOLID CORE SCD SEAT COVER DISPENSER SCHED. SCHEDULE S.D. SOAP DISPENSER S.DET. / SD SMOKE DETECTOR SECT. SECTION SF SQUAREFOOT S.G. SAFETY GLASS SH. SHELF SHT. SHEET SHTHG/ SHT'G SHEATHING SHWR. SHOWER SIM. SIMILAR SND. SANITARY NAPKIN DISPENSER SNR SANITARY NAPKIN RECEPTACLE S.M. SHEET METAL S.O.G. SLAB ON GRADE SPEC. SPECIFICATION SQ. SQUARE S.S. STAINLESS STEEL S.SK. SERVICE SINK STA. STATION STD. STANDARD STL. STEEL STOR. STORAGE STR'L,STRUCT. STRUCTURAL SUSP. SUSPENDED SYM. SYMMETRICAL MECHANICAL ENGINEER SIDER + BYERS ASSOCIATES, INC 192 NICKERSON ST STE 300 SEATTLE, WA 98109 PHONE: 206.285.2966 CONTACT: JON SHAFER, P.E. ELECTRICAL ENGINEER TFWB ELECTRICAL ENGINEERING 1200 WESTLAKE AVE N, STE 509 SEATTLE, WA 98109 PHONE: 206.285.7228 CONTACT: KEVIN WARTELLE GEOTECHNICAL ENGINEER GEOENGINEERS 17425 NE UNION HILL ROAD, SUITE 250 EDMONDS, WA 98020 PHONE: 425.861.6000 CONTACT:DEBRA OVERBAY SURVEY: AHBL 2215 NORTH 30TH STREET, SUITE 300 TACOMA, WA 98403-3350 PHONE: 253.383.3350 CONTACT: DAVID C. FOLLANSBEE, PLS ARBORIST: OSG ONEIL (ATLAS ONE) 17619 NE 67TH CT, SUITE 100 REDMOND, WA 98052 PHONE: 425.429.7800 CONTACT: SHANNON INGEBRIGHT BUILDING ENVELOPE: OAC SERVICES 2200 1ST AVE S SUITE 200 SEATTLE, WA 98134 PHONE: 206.276.0832 CONTACT:KERRY MAY SIGNAGE DESIGNER: VERTICAL VISUAL SOLUTIONS 7036 220TH STREE SE MOUNTLAKE TERRACE, WA 98043 PHONE: 425.361.1562 CONTACT: ANGELA LEVENDA ff ENT PLANNING ing 09/23/2025 FSurface Water Enginering h 09/18/2025 FcAPPROVED 7thhomas AL FIRE AUTHORITY cF 09/19/2025 �4�fl►s`` EHHu:ynh MENT ENGINEERING 09/23/2025 ' )] EWASTEWATER UTILITY well 09/23/2025 T.B.S. TO BE SELECTED T.C. TOP OF CURB TEL. TELEPHONE TEMP TEMPORARY TER. TERRAZZO T&G TONGUE & GROOVE THK. THICK T.O. TOP OF T.P. TOP OF PAVEMENT TPD TOILET PAPER DISPENSER TRD. OR T TREAD T.V. TELEVISION T.O.W. TOP OF WALL TYP. TYPICAL UNF. UNFINISHED U.N.O. UNLESS NOTED OTHERWISE U.O.N. UNLESS OTHERWISE NOTED UR. URINAL VAC. VACUUM V.B. VAPOR BARRIER VCR VINYL CARPET REDUCER VERT. VERTICAL VEST. VESTIBULE V.T.O. VENT TO OUTSIDE W. WEST W/ WITH W.A.B. WEATHER AIR BARRIER (SAME AS WRB) W.R.B. WEATHERIWATER RESISTIVE BARRIER W.C. WATER CLOSET WD. WOOD WDW. WINDOW W.M. WATER METER W/0 WITHOUT WP. WATERPROOF W.R. WATER RESISTANT, WATER -RESISTIVE WSCT. WAINSCOT WT. WEIGHT T ARCHITECTURE + PLANNING + DESIGN 6211 ROOSEVELT WAY NORTHEAST SEATTLE, WA 98115 tel: (206) 522-3830 fax: (206) 522-2456 6235 REGISTERED ARCHITECT BRIAN J. HARRIS °.SIrA7E OF WASHMI��pI ry1 NN CID O C) N U ,I- M W 0 C) 0 O 1 N C) C) O N Q Z) J PERMIT RESUBMITTAL No. Description Date: 1 City Review Comments 7/3/25 Project Title: Sheet Title: Scale: Project No. Date : Sheet 00 Z p >_ a �m OR W Q O _ aZ Z a 9� J Q z oz z O � W W W Z O W - oc a z LLJ COVER SHEET 12" = 1'-0" L I -IL 8/21 /25 TIA R-435401