Loading...
HomeMy WebLinkAboutR-435423LO Nt O i w 19, A 525.6 I \ 525.6 6 •06 I \ 12" VENTILATION 525.1 I \ 5' X 10' l I \ VAULT ACCESS / \ \ \ IE 530.0 12" INLET \\ 48" ACCESS RISER W/ `\ \ PIPE \ 24" SOLID LOCKING LID \ \ 48" ACCESS RISER W/ \ \\ RIM 539.90 \\ \ 24" SOLID LOCKING LID RIM 539.08 IE 529.94 \ \ 52 \ \ \ 525.1 \ A \ \ 8.86' \ F, GRAVEL BACKFILL FOR DRAINS PER WSDOT STD SPEC 9.03-12(4) 12" MIN WIDTH 4" PERFORATED PVC FOOTING DRAIN IE 528.0 z PLAN VIEW LADDER RUNGS FROM ACCESS RISER TO FLOOR (TYP) 0.5' AVG SEDIMENT STORAGE SECTION B-B 48" ACCESS RISER W/ VERTCIAL SCALE 1 "=2.5' 24" SOLID LOCKING LID RIM 536.49 \\ ^ B \ i/' _ \ 48" ACCESS RISER W/ // \\ 12" VENTILATION 24" SOLID LOCKING LID IE 530.85 IE 530.0 6" INLET PIPE RIM 535.46 8" INLET PIPE ------------------- ----------------------------------- ---- ------ P. P . P )01 4.86' \ XL___. 12" VENTILATION 4.86' ::. 525.E / 48" ACCESS RISER W/ 24" SOLID LOCKING LID e RIM 535.51 6 / 12" VENTILATION 525.1 / / 5.0% \ 64' 12" VENTILATION 6" CRUSHED ROCK --__24" OUTLET PIPE IE 525.85 A I • I � ODDOaa 0000 18" INLET PIPE i - - J IE 528.0 GRAVEL BACKFILL FOR DRAINS PER WSDOT STD SPEC 9.03-12(4) 12" MIN WIDTH 0 Q - 4" PERFORATED PVC FOOTING DRAIN IE 526.0 5x10 ACCESS PANEL FG 539.53 \7� 77 \\/\\/\\/\\/\\/\\/\\/\\ \ \ 12" VENTILATION 12" VENTILATION 6 FG 536.49 FG535.51 FG535.46 . TOP OF VAULT EL 533.6 e \ a ° .e - + 0 100 YR W.L. = 531.36 1.48' FREEBOARD - oc ABOVE RISER (EL 531.12� o p � I I o GRAVEL BACKFILL FOR DRAINS - I I " c STD SPEC I I 4 PERFORATED PVC PER WSDOT A 24" OUTLET PIPE FOOTING DRAIN 9.03-12(4) 12" MIN WIDTH - I I TO FLOW CONTROL SCALE 1"=5' IE 528.0 p STRUCTURE NORTH CONCRETE DETENTION VAULT #2 LADDER RUNGS 5.51' LIVE STORAGE DEPTH FROM ACCESS RISER 4 PERFORATED PVC I I FOOTING DRAIN TO FLOOR (TYP) o �,Q P IE 526.0 525.85 � IE I I - o� � IN COMPLIANCE WITH CITY OF RENTON STANDARDS yG� p TOP OF SEDIMENT STORAGE 0.5 AVG SEDIMENT STORAGE v� EL = 525.6 EL = 525.85 - - - - - - - - - o-5.Oq------------------------------------------------i-------------- ------------------------- 2 �1• EL = 525.1 - - � e SECTION A -A VERTCIAL SCALE 1 "=2.5' T ARCHITLCTURL + PLANNIING + DESIGN 6211 ROOSEVELT WAY NORTHEAST SEATTLE, WA 98115 tel: (206) 522-3830 fax: (206) 522-2456 1932 First Ave Suite 500 Imm Seattle, WA 98101 p. 206.725.1211 f. 206.973.5344 engineering pllc www.lpdengine k9i� PERMIT RESUBMITTAL No. Description Date: 6 City Comments 8/21/2025 Project Title: J r m � � Z W O C� Z a Q � QO Q Z W Q z O w z z O z w orf W Z O w Sheet Title: GRADING AND DRAINAGE DETAILS Scale: As indicated Project No.: 21-12 Date : 08/21 /2025 Sheet Number: Cm208 6" CRUSHED ROCK R-435423