Loading...
HomeMy WebLinkAboutR-435445LO Nt I O I w 1 M H io O 12 GM O O DOUBLE CHECK z 'MIN. �� O ASSEMBLY ° F L N GATE VALVE 2" HDPE MIN. N �IMIN. B E BYPASS PIPE B 1i`°�loj IfhIIIIII O IIIIIhI�l O � Z R� L L �Q __ C N NOTES: 1. WHERE PIV IS LOCATED INSIDE THE VAULT, THE VAULT LID SHALL BE CORE DRILLED WITH LINK SEAL OR GROUT TO SEAL THE PIPE PENETRATION. ALTERNATIVE PIV LOCATION SHALL BE APPROVED BY THE FIRE MARSHAL. 2. MINIMUM CLEARANCE OF 6" SHALL BE MAINTAINED BETWEEN VALVES, FITTINGS, AND VAULT WALL. 2" CORP STOP TEMPORARY BRACING 3. ALL PIPE JOINTS SHALL BE RESTRAINED AND CONCRETE BLOCKING IS REQUIRED AT CHANGES IN DIRECTION. 4. CORE DRILL (O.D. +2") CONCRETE VAULT IF KNOCK -OUTS ARE NOT PROVIDED. 2" SADDLE DETAIL NOTES 1. AFTER TEMPORARY BYPASS IS COMPLETE, MATERIALS: OA BACKFLOW ASSEMBLY DCDA PER DETAIL NO.23A, POSITIONED WITHIN ACCESS HATCH TO ALLOW FOR VERTICAL REMOVAL CONTRACTOR TO CLOSE CORP STOP AND Og PIPE CLASS 53 DI PIPE (PExFL OR FLxFL) REMOVE ALL TEMPORARY PIPING AND BRACING O POST INDICATOR VALVE PIV BETWEEN LAST VALVE ON BACKFLOW ASSEMBLY AND FDC, IN ONE OF TWO EX WATER MAIN 2" BRASS POSITIONS SHOWN OTEE TEE (PExFL) HOT TAP CONNECTION OE ADAPTER ADAPTER (FLxMJ) TO EX WATER MAIN BEND 90' BEND ( FLxFL) gF VALVE CHECK VALVE (FLxFL) OFIRE DEPARTMENT FDC PER RRFA REQUIREMENTS, LOCATED DOWNSTREAM OF BACKFLOW CONNECTION ASSEMBLY, INSTALLED ON THE SIDE OF THE VAULT WITH THE LARGEST AVAILABLE SPACE AS SHOWN OCONCRETE VAULT OLDCASTLE PRECAST VAULT OR EQUAL, SIZED TO ACCOMMODATE FDC, PIV, AND CHECK VALVE INSIDE THE VAULT AND MAINTAIN REQUIRED MINIMUM CLEARANCES OACCESS HATCH TWO LOCKING HINGED ALUMINUM DOORS, TRAFFIC- RATED, WITH SLIP RESISTANT TREATMENT, MARKED "WATER", LW PRODUCTS OR EQUAL OLADDER GALVANIZED STEEL LADDER SECURED TO VAULT m O WALL FLANGE MIDSPAN PIPE RESTRAINT WITH CONCRETE BLOCKING, SEAL PIPE PENETRATIONS v WITH WATER -TIGHT GROUT E O PIPE PENETRATION SEAL PIPE PENETRATION WITH WATER -TIGHT GROUT ODRAIN FLOOR DRAIN, MINIMUM 6" PVC, SLOPED TO STORM SEWER OR DAYLIGHT TO " DRAINAGE DITCH WITH WIRE MESH RODENT SCREEN AT DRAIN OUTLET, SEAL PIPE PENETRATION WITH WATER -TIGHT GROUT 3 OBLOCKING CONCRETE BLOCKING PER STANDARD DETAIL 2 - p Q STANDARD DETAIL NTS King county Rev. Date 06/2025 DETAIL NO. O FIRE DEPARTMENT == DANID EVANS ATEB wNoA880CIATESiNc. CONNECTION (FDC) ' 28 Water District No. 90 2" TEMPORARY BYPASS SOURCE CONNECTION KCWD90 STD DTL 28 - FIRE DEPARTMENT CONNECTION 2 NOT USED 3 NOT USED NTS NOT USED 8 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NTS NTS IT' NOT USED 5 NOT USED6 NOT USED 7 T ARCHITIeCTURE + PLANNING + DISIGN 6211 ROOSEVELT WAY NORTHEAST SEATTLE, WA 98115 tel: (206) 522-3830 fax: (206) 522-2456 1932 First Ave Suite 500 M M Seattle, WA 98101 p. 206.725.1211 f. 206.973.5344 engineering pllc www.lpdengi PERMIT RESUBMITTAL No. Description Date: 6 City Comments 8/21/2025 Project Title: r � F� � O Z LLI O C� Z a Q � Q2:z CIO Q Z LL Q O O w Z O ~ z w orf LL1 Z o w LL Sheet Title: WATER DETAILS Scale: As indicated Project No.: 21-12 Date : 08/21 /2025 Sheet Number: Cm503 R-435445