HomeMy WebLinkAboutR-435476LO
Ict
Nt
0
LU
NOTES: NOTES: AT TIME OF PLANTING, NOTE: U O a U
1. TREES PLANTED TOO DEEP WITHOUT EXPOSING ROOT FLARE WILL BE 1. TREES NOT PLANTED IN CONFORMANCE WITH THIS TRIM DAMAGED 1. TREES NOT PLANTED IN CONFORMANCE D O o g �QO O NOTE: GROUNDCOVER PLANTING PLAN
REJECTED AND SHALL BE REMOVED AND REPLANTED AT PROPER DEPTH. DETAIL WILL BE REJECTED BY THE LANDSCAPE BRANCHES. WITH THIS DETAIL WILL BE REJECTED BY a Q 1. ALL GROUNDCOVER TO BE PLANTED
2. REPLACEMENT OR REPLANTING OF REJECTED TREES WILL BE DONE AT THE ARCHITECT. REPLACEMENT OF REJECTED TREES WILL THE LANDSCAPE ARCHITECT. °� Q Qa AT EQUAL TRIANGULAR SPACING PER O O
CONTRACTOR'S EXPENSE. BE DONE AT THE CONTRACTOR'S EXPENSE. REPLACEMENT OF REJECTED TREES O Q O a O.C. SPACING ON LEGEND.
3. REMOVE EXCESS SOIL THAT MAY HAVE ACCUMULATED ABOVE THE TRUNK 2. PLANTING INCLUDES REMOVAL OF STAKES ONE YEAR STAKE TREE WITH WILL BE DONE AT THE CONTRACTOR'S
FLARE PRIOR TO DIGGING AT NURSERY. EXPOSE AND LOCATE TRUNK FLARE AFTER INSTALLATION. TWO 2"X2"X8' STAKES EXPENSE. SPACING X .86 FOR O O O
PRIOR TO PLANTING. \ ' SPREAD ACROSS Qg I Oo TRIANGULAR PATTERN
4. PRUNE ANY GIRDLING OR ADVENTITIOUS ROOTS PRIOR TO BACKFILLING. FROM EACH OTHER. AT TIME OF PLANTING, TRIM O �Q
DAMAGED BRANCHES. g g 12" MIN
TRUNK FLARE a� Qao Qg g FROM CURB -
APPROVED TREE TIE SPACING
BOTTOM OF TRUNK FLARE. 1
LOCATE BOTTOM OF TRUNK FLARE 1" MIN. ROOTBALL 5 0 MATERIAL SET LOOSE ROOTBALL 5.0.0 AS SPECIFIED
STAKE TREE WITH TWO 2"X2"X8'
TO ALLOW FOR
ABOVE ADJACENT FINISH GRADE. TRUNK GROWTH STAKES SPREAD ACROSS FROM g, aka
MULCH LAYER, HOLD OFF
3" MULCH. NO MULCH AGAINST EACH OTHER
FROM TREE TRUNK /I APPROVED TREE TIE MATERIAL 3" OF MULCH. au ��
3" MULCH. NO MULCH AGAINST TRUNK DRIVE STAKES AT TRUNK SET LOOSE TO ALLOW FOR NO MULCH AGAINST ab' a dP
\ \ \ \ \ FINISH GRADE TRUNK GROWTH THE BASE OF THE
Q z //\//\/ ROOTBALL EDGE
\ \ / / 3"-4" HIGH WATERING RING 3"-4" HIGH WATERING RING PLANT
m \ \ REMOVE WIRE BASKET NO DRIVE STAKES AT
/\/\ /\/\/ EXCEPTIONS AND ANY ROOTBALL EDGE
O \ \\ \\ \\ \ ) SCARIFY SIDES OF PLANTING PIT
O // // // // // OTHER SYNTHETIC MATERIAL SCARIFY SIDES OF PLANTING PIT \\/\\/\\ /\\/\\/ BACKFILL WITH oo•.°oo•.° ////
/\/\\/
FROM ROOTBALL. CUT BACK \\�\j j\j/ BACKFILL WITH EXISTING SOIL EXCAVATED SOIL.
AND REMOVE BURLAP FROM BACKFILL WITH EXISTING SOIL / DRIVE STAKES 6"-12" \/\/\ /\/\/ WATER THOROUGHLY.
—i I I -I I I -I I I —I I I -I I - 111 TOP AND SIDE OF ROOTBALL. INTO UNDISTURBED DO NOT DISTURB SUBGRADE
=III—III=III=III=III—III=III—� SET BALL ON COMPACTED DO NOT DISTURB SUBGRADE BELOW SOIL BELOW BELOW ROOTBALL TO REDUCE
SOIL MOUND TO PREVENT ROOTBALL TO REDUCE SETTLING. 3X ROOTBALL ROOTBALL SETTLING.
SETTLING. DRIVE STAKES 6"-12" INTO 2X ROOTBALL
3X ROOTBALL UNDISTURBED SOIL BELOW
Df OOTBALL 2 CONIFER TREE PLANTING W/ STAKE 3 DECIDUOUS TREE PLANTING ROOTBALL 4 GROUNDCOVER PLANTING
1" = P-2023-HTH-02 3/8" = 1'-0" P-2023-HTH 3/8" = 1'-0" P-2023-HTH-70 1/2" = 1'-0" P-2023-HTH-66
a �Ao 0 1a
off' pad a Qa
3" MULCH. �� �� L? D�
NO MULCH o P� pp� OQa
AGAINST THE BASE
OF THE PLANT
BACKFILL WITH
EXCAVATED SOIL
REMOVE BURLAP
FROM TOP AND SIDES
OF ROOT BALL DOWN
INTO GROUND. SET
TOP OF BALL FLUSH
WITH FINISH GRADE.
: ODQ Qp oa
D � aoa
a QQ Q Quo 00
Vv���oaPt5l �
O pp
-I 1I—
1 � , —,
II, IIIlil i �111III,111=IIIIIIIII
SCARIFY
SIDES OF
PLANTING PIT
LOOSEN / PULL OUT ROOT:
FROM CONTAINER GROWN
PLANTS
III=
-III—II
-III=111-
iii—i11=11i
�—
SHRUB PLANTING
NTS P-2023-HTH-03
BUILDING OR OTHER
VERTICAL SURFACE AS
OCCURS
EXPANSION JOINT
CONCRETE PAVING, TYP.
COMPACTED SUBBASE,
PER CIVIL
COMPACTED
SUBGRADE, PER CIVIL
VERTICAL EDGE CONDITION
EXPANSION JOINTS
CONTRACTION JOINTS
NOTE:
1. SEE DECORATIVE CONCRETE SPECS FOR FINISH INFORMATION
2. SEE CIVIL C600 SERIES FOR PROFILE DIMENSIONS
CONCRETE PAVING
BUILDING FACADE
NO PLANTING ZONE
5/8" MINUS CRUSHED GRAVEL
COMPACTED TO 95%
FINISH GRADE
STEEL LANDSCAPE EDGING 7
5.0.
MIRAFI 140 NON -WOVEN
GEOTEXTILE FABRIC
SUBGRADE COMPACTED TO 95%
SHRUB SIDE TOP OF
SUBGRADE
CONDITIONS VARY, SEE PLAN
3/16" X 4" STEEL EDGING
COLOR SHALL BE BLACK
COMPACT SUBGRADE ON
EITHER SIDE OF EDGING TO
MAINTAIN STABILITY
STAKE AT ALL CURVE
RETURNS, CURVE MIDPOINTS,
AND AT 36" O.C. MIN.
NOTES:
1. INSTALL EDGING PER MANUFACTURER'S SPECIFICATIONS WITH TOP OF EDGING 1/4" TO
1/2" ABOVE COMPACTED FINISH GRADE (TURF SIDE).
GRAVEL MAINTENANCE STRIP 7 STEEL LANDSCAPE EDGING
1/2" = 1'-0" P-2024-RRF-04 1" = 1'-0" P-2024-RRF-10
3/8" PRE -MOLDED EXPANSION
FILLER WITH SEALANT. IN AREAS OF
COLORED CONCRETE, SEALANT TO
MATCH ADJACENT COLOR
FULL DEPTH
JOINT
1/4" WIDE JOINT. 1/4
DEPTH OF SLAB,
MAX. SEE SPECS
FOR MORE INFO
LANDSCAPE EDGE CONDITION
I I-f)"
THICKENED EDGE CONDITION
PLANTING SOIL
TOP OF
MULCH
FINISH GRADE
P-2024-RRF-11
CURRENT PLANNING
jding 09/23/2025
T
ARCHITECTURE + PLANNING + DESIGN
6211 ROOSEVELT WAY
NORTHEAST
SEATTLE, WA 98115
tel: (206) 522-3830
fax: (206) 522-2456
�I li
I- _
T A C O M A• SEATTLE • SPOKANE • TRI-CITIES
1200 6th Avenue, Suite 1620 Seattle, WA 98101 N
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB CO
T
O
OF WA Sy O
R . S K4A LO
�2Z0
OS EXP.031�����
cq PE it, RG
08/20/2025
PERMIT
RESUBMITTAL
No. Description Date:
6 CITY CORRECTIONS 8/21/25
Project Title:
Sheet Title:
Q
0
J
�
O
r
�
_
v
Q
LL1O
�
LL
3:
az
H
Z
a
W
z
0
w
77
z
O
w
LV
Z
o
z
a
ry
LL
DETAILS
Scale: AS INDICATED
Project No.: 11-78
Date : 8/21/25
Sheet Number
R-435476
L5mOmO