HomeMy WebLinkAboutR-435479LO
Ict
0
I
0
LU
PVC SCH 8- PIPE AND FITTINGS
FROM DCVA
BALL VALVE
COIL 30" EXTRA WIRE
SCH. 80
REMOTE CONTROL VALVE
DBRY SPLICES
THREADED
SCH 80 UNION
ELBOW
FINISH GRADE IN LAWN
COW -TAGS
FINISH GRADE IN PLANTING
BED
FINISH GRADE IN LAWN
cJj
Y"
FINISH GRADE IN MULCH
FILTER FABRIC, WRAP UP ALL
�O
SIDES ABOVE OPENINGS
MASTER VALVE^'
SCH-80 NIPPLE
`9
SCH. 80 NIPPE F�
LATERAL PIPE
SCH-80 UNION
BOLT VALVE BOXES TOGETHER
6X2X16 CONC. BLOCK, ONE PER
! CORNER (4 TOTAL)
r
0
o
0
0
0
0
0
0
0
0
0
0
0
0
�
0
0
o
0
o00
0
2 CU. FT. WASHED DRAIN ROCK
� SCH
80
SCH 40
<
�
MAIN LINE
< PVC
PVC
DRAIN ROCK, MIN. 6" DEPTH
�
FILTE FABRIC
NOTES:1.
USE VALVE BOX W EXTENSIONS. SET 2" ABOVE GRADE IN SHRUBS, FLUSH IN
TURF
2. USE TEFLON TAPE FOR ALL THREADED FITTINGS, NO PIPE DOPE
3. KEEP MIN. 3" CLEARANCE AROUND VALVE ON ALL SIDES.
4. LEAVE EXTRA 30" CONTROL WIRE COILED INSIDE VALVE BOX
5. USE DBR WATERPROOF CONNECTORS
MASTER VALVE
1 1/2" = 1'-0"
QCV
QUICK COUPLER VALVE
1 1/2" = 1'-0"
P-2024-RRF-13
FINISH GRADE
FLUSH IN LAWN AREAS
2" IN SHRUB AREAS
QUICK COUPLER VALVE AS
SPECIFIED
TWO (2) STAINLESS STEEL
CLAMPS
SCH. 80 NIPPLE, LENGTH AS REQ.
3/4" CRUSHED ROCK, MIN 6" DEEP
TWO (2) 3" PVC SCH. 80 NIPPLE
12" PVC SCH. 80 NIPPLE
MAIN LINE
THREE (3) PVC SCH. 80 ELLS
1/2" X 36" GALV. STEEL PIPE
P-2024-RRF-15
REMOTE CONTROL VALVE
1 1/2" = 1'-0"
P-2024-RRF-12
SPRAY NOZZLE, SEE SCHEDULE
FINISH GRADE
POP-UP SPRINKLER, SEE
SCHEDULE.
USE BOTTOM INLET ONLY
SWING ASSEMBLY. 8" MIN, 30"
MAX. LENGTH.
PVC SCH 40 TEE OR ELL
PCV LATERAL PIPE, SIZE PER
PLAN
NOTE:
1. SET HEADS PLUMB OR SQUARE TO THE SLOPE
2. PLACE HEADS MIN 4" FROM EDGE OF PAVING
3. USE TEFLON TAPE AT ALL THREADED FITTINGS
_-� POP-UP SPRAY OR ROTATOR HEAD
1/8" = 1'-0"
P-2024-RRF-16
KEEP 12'
APART
ELECTRIC AUTOMATIC
CONTROLLER AS SPECIFIED.
WALL MOUNTED BRACED PER
MANUFACTURER(SEE
IRRIGATION PLAN FOR
LOCATION)
2" DIA. SCH. 40 PVC CONDUIT
WITH LONG SWEEP ELL FOR
OF DIRECT BURIAL WIRES TO
VALVES. ALLOW A MAXIMUM
OF 24 WIRES PER CONDUIT
1" METAL CONDUIT WITH LONG
SWEEP ELL FOR 110V POWER
SOURCE AS PER ELECTRICAL
CODES
CONCRETE MOUNTING PAD,
EXTEND 6" BEYOND OUTSIDE
DIMENSIONS OF CONTROLLER.
SLOPE FOR DRAINAGE
EV-CAB-COM CABLE IF
APPLICABLE. INSTALL IN 1"
CONDUIT
8 FT. COPPER GROUND AS PER
LOCAL CODE
CONTROLLER WALL MOUNTED
1/2" = 1'-0"
P-2024-RRF-19
CURRENT PLANNING A �'
jding 09/23/2025 '
T
ARCHITECTURE + PLANNING + DESIGN
6211 ROOSEVELT WAY
NORTHEAST
SEATTLE, WA 98115
tel: (206) 522-3830
fax: (206) 522-2456
I_ _
T A GO M A• SEATTLE • SPOKANE • TRI-CITIES
1200 6th Avenue, Suite 1620 Seattle, WA 98101 N
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB CO
T
0
OF WA Sy (D
PAC, R . S k�A �tiC LO
�2Z0�
OS
cq PE ARG
08/20/2025
PERMIT
RESUBMITTAL
No. Description Date:
6 CITY CORRECTIONS 8/21/25
Project Title:
0
J
ry
O
r
�
_
v
Q
LLJO
�
LL
3:
az
H
a
W
z
0
w
z
O
w
of
LV
Z
o
z
a
ry
LL
Sheet Title:
IRRIGATION
DETAILS
Scale: AS INDICATED
Project No.: 11-78
Date : 8/21/25
Sheet Number
R-435479
L5ml ol