Loading...
HomeMy WebLinkAboutR-435482LO 0 UJ 12" MAX. HOUSE KEEPING PAD - REFER TO STRUCTURAL PRE -PRIMED, PTD TUBE STEEL POST - REFER TO STRUCTURAL cU w CU w GENERATOR WITH DAY TANK REFER TO ELECTRICAL CONCRETE PAVING WITH SMOOTH FINISH & CONCRETE SEALER - REFER TO CIVIL BOARD FORM CONCRETE — RETAINING WALL - REFER TO STRUCT. 18 A1.7 19 A1.7 11112" EQ EQ EQ EQ EQ 33' - 71 /2" 52' - 5" FS - GENERATOR/WASTE ENCLOSURE - ENLARGED PLAN Scale: 3/16" = V-0" PRE -PRIMED, PTD TUBE STEEL POST - REFER TO STRUCTURAL PRE -FINISHED METAL FASCIA 13 PRE -PRIMED, PTD TUBE STEEL A1.7 BEAM - REFER TO STRUCTURAL B.O. ROOF 0 0 CV 0 PAVEMENT 19 A1.7 co ♦ ■ ENCLOSURE GATE BOARD FORM CONCRETE RETAINING WALL - REFER 11 10 TO STRUCT. A1.8 A1.8 FS - GENERATOR/WASTE ENCLOSURE NORTH ELEVATION Scale: 3/16" = V-0" 41 /2" CV co 0 C3 � LU 19 A1.7oi 10 A1.8 19'-3" 18' - 6" 141/2" EQ EQ 6" Li CONCRETE PAVING WITH SMOOTH FINISH & CONCRETE p ° 4 SEALER - REFER TO CIVIL a s 9 Al a GALV. L4X4X1/4 ANGLE MOUNTED ° ° TO PAVING 00 aQ - ° °L---- a 9" CONCRETE CURB - REFER TO m °' STRUCTURAL V ° 6" CONCRETE CURB, TYP. REFER r is a ; . TO CIVIL ..�. ii r- ENCLOSURE GATE 8 g " i" HOLE FOR CANE BOLT- TYPICAL it air o fl _ 4 4b 14 '.. 1'- 61 /2" 1'- 6112" ALT. 1 WASTE ENCLOSURE ENLARGED PLAN Scale: 3/16" = V-0" EQ 4112" 18'-91/2" T-6' CLR PRE -FINISHED METAL SIDING - MP-1 - FIELD PRIME AND PAINT INTERIOR SURFACE TO MATCH PRE -FINISHED SURFACE PRE -PRIMED, PTD STEEL ANGLE - REFER TO STRUCTURAL /—PRE-PRIMED, PTD TUBE STEEL POST - REFER TO STRUCTURAL GENERATOR WITH DAY TANK - REFER TO ELECTRICAL is CV LLARDS, TYP. 2 A1.8 8'-0" 3'-2" CLR ISHED METAL FASCIA ALT. 1 WASTE ENCLOSURE ROOF PLAN Scale: 3/16" = V-0" NOTE FOR PLANS REVIEWER: REFER TO PERMIT NO. B25001712 AND B25001711 FOR BUILDING PERMIT APPROVAL OF TRASH ENCLOSURE. PLANS INCLUDED IN CIVIL CONSTRUCTION PERMIT SET FOR REFERENCE ONLY. FS GENERATOR/WASTE ENCLOSURE - ROOF PLAN Scale: 3/16" = V-0" B.O. ROOF 0 (V PAVEMENT FS -GENERATOR/ WASTE ENCLOSURE EAST ELEVATION Scale: 3/16" = V-0" B.O. ROOF GRADE 10 11 A1.8 A1.8 D METAL FASCIA PTD TUBE STEEL R TO STRUCTURAL PTD TUBE STEEL R TO STRUCTURAL D METAL SIDING - PRIME AND PAINT RFACE TO MATCH D SURFACE CURB, TYP. - REFER E CURB - REFER TO I PRE -FINISHED METAL FASCIA PRE -PRIMED, PTD TUBE STEEL BEAM - REFER TO STRUCTURAL PRE -PRIMED, PTD TUBE STEEL POST - REFER TO STRUCTURAL 9" CONCRETE CURB REFER TO STRUCTURAL :NCLOSURE GATE ALT. 1 WASTE ENCLOSURE SOUTH ELEVATION Scale: 3/16" = V-0" GENERATOR WITH DAY TANK - REFER TO ELECTRICAL VISHED METAL SIDING - _IELD PRIME AND PAINT DR SURFACE TO MATCH VISHED SURFACE EMENT FORM CONCRETE IING WALL - REFER TO T. . , QNUOUS R-10 RIGID INSULATION, TYP. FS - GENERATOR/ WASTE ENCLOSURE WEST ELEVATION Scale: 3/16" = V-0" PRE -FINISHED METAL FASCIA PRE -PRIMED, PTD TUBE STEEL BEAM - REFER TO STRUCTURAL PRE -PRIMED, PTD TUBE STEEL POST - REFER TO STRUCTURAL B.O. ROOF 0 o bo Co PAVEMENT zo PRE -FINISHED METAL SIDING - MP-1 - FIELD PRIME AND PAINT INTERIOR SURFACE TO MATCH CURRENT PLANNING o PRE -FINISHED SURFACE jding 09/23/2025 �� 9" CONCRETE CURB - REFER TO STRUCTURAL ALT. 1 WASTE ENCLOSURE EAST ELEVATION Scale: 3/16" = V-0" T A ARCHITECTURE + PLANNING + DESIGN 6211 ROOSEVELT WAY NORTHEAST SEATTLE, WA 98115 tel: (206) 522-3830 fax: (206) 522-2456 6235 REGISTERED ARCHITECT BRIAN J. HARRIS SIIfA7E OF WA3HAl�7�Ipl N 00 00 T 0 U—) N U 00 0 C) 0 O N C) C) I Nt N Q Z) J PERMIT RESUBMITTAL No. I Description Date: 6 City Comments 8/21/25 Project Title: Z Cl Q~ J m O � W Q Q Z Q Z L LL J Q z O_LU z O H Z W w Z Z O W a Z W r6 Sheet Title: TRASH ENCLOSURE ENLARGED PLANS AND ELEVATIONS Scale: 3/16" = V-0" Project No.: 21-12 Date : 8/21/25 Sheet Number: Alma R-435482