HomeMy WebLinkAboutR-435482LO
0
UJ
12" MAX. HOUSE KEEPING PAD -
REFER TO STRUCTURAL
PRE -PRIMED, PTD TUBE STEEL
POST - REFER TO STRUCTURAL
cU
w
CU
w
GENERATOR WITH DAY TANK
REFER TO ELECTRICAL
CONCRETE PAVING WITH
SMOOTH FINISH & CONCRETE
SEALER - REFER TO CIVIL
BOARD FORM CONCRETE —
RETAINING WALL - REFER TO
STRUCT.
18
A1.7
19
A1.7
11112" EQ EQ EQ EQ EQ
33' - 71 /2"
52' - 5"
FS - GENERATOR/WASTE ENCLOSURE - ENLARGED PLAN
Scale: 3/16" = V-0"
PRE -PRIMED, PTD TUBE STEEL
POST - REFER TO STRUCTURAL
PRE -FINISHED METAL FASCIA
13
PRE -PRIMED, PTD TUBE STEEL A1.7
BEAM - REFER TO STRUCTURAL
B.O. ROOF
0
0
CV
0
PAVEMENT
19
A1.7
co ♦ ■
ENCLOSURE GATE BOARD FORM CONCRETE RETAINING WALL - REFER
11 10 TO STRUCT.
A1.8 A1.8
FS - GENERATOR/WASTE ENCLOSURE NORTH ELEVATION
Scale: 3/16" = V-0"
41 /2"
CV
co
0
C3
�
LU
19
A1.7oi
10
A1.8
19'-3"
18' - 6" 141/2"
EQ EQ
6"
Li CONCRETE PAVING WITH
SMOOTH FINISH & CONCRETE
p ° 4 SEALER - REFER TO CIVIL
a s 9 Al
a
GALV. L4X4X1/4 ANGLE MOUNTED
°
° TO PAVING
00
aQ
- ° °L---- a 9" CONCRETE CURB - REFER TO
m °' STRUCTURAL
V ° 6" CONCRETE CURB, TYP. REFER
r is a ; . TO CIVIL
..�. ii r-
ENCLOSURE GATE
8
g " i"
HOLE FOR CANE BOLT- TYPICAL
it
air
o fl _
4
4b 14
'..
1'- 61 /2" 1'- 6112"
ALT. 1 WASTE ENCLOSURE ENLARGED PLAN
Scale: 3/16" = V-0"
EQ 4112"
18'-91/2" T-6'
CLR
PRE -FINISHED METAL SIDING - MP-1 - FIELD PRIME
AND PAINT INTERIOR SURFACE TO MATCH
PRE -FINISHED SURFACE
PRE -PRIMED, PTD STEEL ANGLE - REFER TO
STRUCTURAL
/—PRE-PRIMED, PTD TUBE STEEL POST - REFER TO
STRUCTURAL
GENERATOR WITH DAY TANK - REFER TO
ELECTRICAL
is
CV
LLARDS, TYP.
2
A1.8
8'-0" 3'-2"
CLR
ISHED METAL FASCIA
ALT. 1 WASTE ENCLOSURE ROOF PLAN
Scale: 3/16" = V-0"
NOTE FOR PLANS REVIEWER:
REFER TO PERMIT NO. B25001712 AND B25001711 FOR BUILDING PERMIT APPROVAL OF TRASH
ENCLOSURE. PLANS INCLUDED IN CIVIL CONSTRUCTION PERMIT SET FOR REFERENCE ONLY.
FS GENERATOR/WASTE ENCLOSURE - ROOF PLAN
Scale: 3/16" = V-0"
B.O. ROOF
0
(V
PAVEMENT
FS -GENERATOR/ WASTE
ENCLOSURE EAST ELEVATION
Scale: 3/16" = V-0"
B.O. ROOF
GRADE
10 11
A1.8 A1.8
D METAL FASCIA
PTD TUBE STEEL
R TO STRUCTURAL
PTD TUBE STEEL
R TO STRUCTURAL
D METAL SIDING -
PRIME AND PAINT
RFACE TO MATCH
D SURFACE
CURB, TYP. - REFER
E CURB - REFER TO
I
PRE -FINISHED METAL FASCIA
PRE -PRIMED, PTD TUBE STEEL
BEAM - REFER TO STRUCTURAL
PRE -PRIMED, PTD TUBE STEEL
POST - REFER TO STRUCTURAL
9" CONCRETE CURB REFER TO
STRUCTURAL
:NCLOSURE GATE
ALT. 1 WASTE ENCLOSURE SOUTH ELEVATION
Scale: 3/16" = V-0"
GENERATOR WITH DAY TANK -
REFER TO ELECTRICAL
VISHED METAL SIDING -
_IELD PRIME AND PAINT
DR SURFACE TO MATCH
VISHED SURFACE
EMENT
FORM CONCRETE
IING WALL - REFER TO
T.
. , QNUOUS R-10 RIGID
INSULATION, TYP.
FS - GENERATOR/ WASTE
ENCLOSURE WEST ELEVATION
Scale: 3/16" = V-0"
PRE -FINISHED METAL FASCIA
PRE -PRIMED, PTD TUBE STEEL
BEAM - REFER TO STRUCTURAL
PRE -PRIMED, PTD TUBE STEEL
POST - REFER TO STRUCTURAL
B.O. ROOF
0
o bo
Co
PAVEMENT
zo
PRE -FINISHED METAL SIDING -
MP-1 - FIELD PRIME AND PAINT
INTERIOR SURFACE TO MATCH
CURRENT PLANNING o PRE -FINISHED SURFACE
jding 09/23/2025 �� 9" CONCRETE CURB - REFER TO
STRUCTURAL
ALT. 1 WASTE ENCLOSURE EAST ELEVATION
Scale: 3/16" = V-0"
T A
ARCHITECTURE + PLANNING + DESIGN
6211 ROOSEVELT WAY
NORTHEAST
SEATTLE, WA 98115
tel: (206) 522-3830
fax: (206) 522-2456
6235 REGISTERED
ARCHITECT
BRIAN J. HARRIS
SIIfA7E OF WA3HAl�7�Ipl
N
00
00
T
0
U—)
N
U
00
0
C)
0
O
N
C)
C)
I
Nt
N
Q
Z)
J
PERMIT
RESUBMITTAL
No. I Description Date:
6 City Comments 8/21/25
Project Title:
Z
Cl
Q~
J
m
O
�
W
Q
Q
Z
Q
Z
L
LL
J
Q
z
O_LU
z
O
H
Z
W
w
Z
Z
O
W
a
Z
W
r6
Sheet Title:
TRASH ENCLOSURE ENLARGED PLANS AND
ELEVATIONS
Scale: 3/16" = V-0"
Project No.: 21-12
Date : 8/21/25
Sheet Number:
Alma