Loading...
HomeMy WebLinkAboutR-435485LO I 0 I W It 0 04 N ry U ry Q� ILL Q� ry ry N N ILL ry c 0 a� ry N N U O 0 Y 0 Q 1 1'-712" 14'-71/2" RETAINING HEIGHT = 2'-0" 6" CONCRETE CURB, TYP. - REFER TO CIVIL =Q BOARD FORM CONCRETE RETAINING WALL - REFER TO STRUCT. a G 0 x ° - 11- ° ic? w 100 z i¢ C � FACE OF BUILDING NOTE: • REFER TO A1.1 FOR BALANCE OF NOTES AND DIMS NOT SHOWN ON THIS PLAN 1 REFER TO C-201 AND C-202 FOR GRADING. • REFER TO DETAIL FS-S3.10 AND FS-S3.11 FOR STRUCTURAL DETAILS • MAXIMUM RETAINING HEIGHT PER RMC 4-4-50- C-1.0 SHOWN PER PERMITTING PURPOSE ONLY RETAINING WALL 4 ENLARGED PLAN Scale: 1/8" = V-0" NOTE: • REFER TO A1.1 FOR BALANCE OF NOTES AND DIMS NOT SHOWN ON THIS PLAN REFER TO C-201 AND C-202 FOR GRADING. C REFER TO DETAIL FS-S3.10 AND FS-S3.11 FOR STRUCTURAL DETAILS • MAXIMUM RETAINING HEIGHT PER RMC 4-4-50-C-1.0 SHOWN PER PERMITTING PURPOSE ONLY GRADE BEYOND SHOWN = DASHED c� Q= BOARD FORM CONCRETE o z RETAINING WALL - REFER TO N Q STRUCT. 538' - 0" _ = N LU FS T.O. SLAB > FOOTING SHOWN FOR REFERENCE ONLY RETAINING WALL 4 WEST ELEVATION Scale: 1/8" = 1'-0" NOTE: • REFER TO A1.1 FOR BALANCE OF NOTES AND DIMS NOT SHOWN ON THIS PLAN • REFER TO C-201 AND C-202 FOR GRADING. • REFER TO DETAIL FS-S3.10 AND FS-S3.11 FOR STRUCTURAL DETAILS • MAXIMUM RETAINING HEIGHT PER RMC 4-4-50-C-1.0 SHOWN PER PERMITTING PURPOSE ONLY GRADE BEYOND SHOWN DASHED LU BOARD FORM CONCRETE o z RETAINING WALL - REFER TO NISTRUCT. w w _ � 538' - 0" > b FS T.O. SLAB —III— A I -1 I I-IIIA I -III -III- III -I �_ III — FOOTING SHOWN DASHED FOR REFERENCE RETAINING WALL 4 NORTH ELEVATION Scale: 1/8" = V-0" PRE -FINISHED METAL SIDING - MP-1 - FIELD PRIME AND PAINT INTERIOR SURFACE TO MATCH PRE -FINISHED SURFACE 18 PRE -PRIMED, PTD STEEL ANGLE - A1.7 REFER TO STRUCTURAL PRE -PRIMED, PTD TUBE STEEL POST - REFER TO STRUCTURAL &><21 K> K> ° - 538' - 0" ° FS T.O. SLAB RETAINING WALL 1 WEST ELEVATION Scale: 1/8" = 1'-0" NOTE: • REFER TO A1.1 FOR BALANCE OF NOTES AND DIMS NOT SHOWN ON THIS PLAN • REFER TO C-201 AND C-202 FOR GRADING. • REFER TO DETAIL FS-S3.10 AND FS-S3.11 FOR STRUCTURAL DETAILS • MAXIMUM RETAINING HEIGHT PER RMC 4-4-50-C-1.0 SHOWN PER PERMITTING PURPOSE ONLY E: • REFER TO A1.1 FOR BALANCE OF NOTES AND DIMS NOT SHOWN ON THIS PLAN • REFER TO C-201 AND C-202 FOR GRADING. • REFER TO DETAIL FS-S3.10 AND FS-S3.11 FOR STRUCTURAL DETAILS • MAXIMUM RETAINING HEIGHT PER RMC 4-4-50-C-1.0 SHOWN PER PERMITTING PURPOSE ONLY co BOARD FORM CONCRETE RETAINING WALL - REFER TO STRUCT. 6-0" VINYL COATED, SLATTEC CHAIN LINK FENCE - RFER TO 12/A1.8 RETAINING WALL 1 ENLARGED PLANS Scale: 1/8" = 1'-0" G 6-0" VINYL COATED, SLATTED CHAIN LINK FENCE - RFER TO 12/A1.8 GRADE BEYOND SHOWN DASHED N L.L -� i0 > AN----BOARDFORMCONCRETE RETAINING WALL - REFER TO STRUCT. FOOTING SHOWN DASHED FOR REFERENCE T C111 ARCHITECTURE + PLANNING + DESIGN 6211 ROOSEVELT WAY NORTHEAST SEATTLE, WA 98115 tel: (206) 522-3830 fax: (206) 522-2456 6?.36 REGISTERED ARCHITECT BRIAN J. HARRIS SIIfA7E OF WA3HAl�7�Ipl 00 00 T 0 C) N U co 0 C) 0 O 1 N r 0— C) C) C) I N Q Z) J PERMIT RESUBMITTAL No. Description I Date: 1 City Review Comments 1 7/3/25 Project Title: 00 Z 0 >- Q J ~ ry, m O W Q O Q Z Q Z LIL J Q z O z O f— z LU W LOf w Z Z O W a z w Sheet Title: RETAINING WALL PLANS AND ELEVATIONS Scale: 1/8" = Project No.: 21-12 Date : 8/21/25 Sheet Number: Al Al m6 R-435485