HomeMy WebLinkAboutR-4354920 Docusign Envelope ID CAEEA226-F133431A-9622-23AB6EE84358 V-11 • 2'-6' 1'-11• 2'-6" (TYP.) o (TYP.) Q (TYP.) (TYP.) 7 PLAN VEW CHAMFERS NOT SHOWN (�� PUBLIC WORKS �� � DEPARTMENT �FNTO? KEY NOTES O GRID OF #3 REBAR SPACED AT V-0" CENTERS LATERALLY AND LONGITUDINALLY. 0 4" DIAMETER X 1/2- DEEP SUMP SLOPE FOUNDATION WITHIN CABINET FOOTPRINT TOWARD SUMP. O 3/8" DIAMETER POLYETHYLENE TUBING FOR DRAIN. TUBING SHALL BE STRAIGHT BUT SLOPE DOWNWARD A MINIMUM OF 1". 0 CONDUITS TO FIELD EQUIPMENT PER CONTRACT O SERVICE ENTRANCE CONDUIT. ALIGN WITH SERVICE WIRE -WAY IN THE CABINET. Q SERVICE GROUND ELECTRODE CONDUITS. Oi GROUND ROD GROUND RODS SHALL BE A MINIMUM OF 6 FEET APART, GROUNDING SHALL BE PER WSDOT STANDARD PLAN J-60.05. Qe GROUND ROD WELL (GROUND TILE) - 12" DIAMETER CONCRETE. GENERAL NOTES 1. FOUNDATION PADS AND RISERS SHALL BE CHAMFERED ON ALL EDGES. TOP OF FOUNDATION PADS CONSTRUCTED WITHIN SIDEWALK SHALL BE FLUSH WITH TOP OF SIDEWALK AND NO CHAMFER ON PAD EDGES. TOP OF PAD SHALL BE FINISHED BY A CONCRETE CONTRACTOR. 2. CONCRETE SHALL BE CLASS 4000P. 3. PLACE A SILICONE SEAL BETWEEN THE FOUNDATION AND CABINET, WOODEN SHIMS SHALL NOT BE USED. 4, ANCHOR BOLTS AND THEIR SPACING TO BE SUPPLIED BY CABINET MANUFACTURER AND SUBMITTED TO THE CITY FOR APPROVAL. 5. CONDUIT SIZES/QUANTITIES SHALL BE INSTALLED PER THE CONTRACT PLANS, EXCEPT EACH CABINET SHALL HAVE ONE 2" SPARE INSTALLED BETWEEN CABINET AND CORRESPONDING JUNCTION BOX 6 2" CONDUIT SHALL BE PLACED FROM THE ELECTRICAL SERVICE TO THE CONTROLLER CABINET 7. REBAR SHALL MEET ASTM A706 GRADE 60. 8. ALL REBAR DIMENSIONS ARE OUT TO OUT. 9. #3 BAR BENDS SHALL HAVE 1 5 INCH INSIDE DIAMETER FOR STIRRUPS AND TIES, ALL OTHER BARS SHALL BE 2.25 INCH INSIDE DIAMETER 10 #4 BAR BENDS SHALL HAVE 2 INCH INSIDE DIAMETER FOR STIRRUPS AND TIES. ALL OTHER BARS SHALL BE 3 INCH INSIDE DIAMETER. Oi #4 N E04 iV � #14 2'-0- �i 1'-1• 1'-r REINFORCING STEEL BENDING DIAGRAM CABINET FOUNDATION DETAILS DocuSign Envelope ID: 894DB72E-3255-4A63-AOF1-38A20AAF74CA GENERAL NOTES: STD. PLAN - 126.1 U ,J. QVED: Martin Pastucha 4/14/2025 DATE 1. ALL EXISTING TRANSPORTATION INFRASTRUCTURE FEATURES SHALL BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS). 2. ALL TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 3. ALL EXISTING OR PROPOSED TRANSPORTATION INFRASTRUCTURE FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT PROWAG ADA STANDARDS (I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). 4. ALL NEW TRAFFIC SIGNALS SHALL BE CONSTRUCTED WITH FIBER COMMUNICATION CONNECTION TO CITY OF RENTON TRANSPORTATION FIBER OPTIC NETWORK. 5. ALL TRANSPORTATION INFRASTRUCTURE FEATURES THAT ARE TO BE REMOVED AND REINSTALLED AT A LATER DATE SHALL BE RE -INSTALLED TO CURRENT STANDARDS. 6. ALL CONDUIT SHALL BE PVC SCHEDULE 80. 7. SIGNAL POLE, LUMINAIRE, AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 8. ALL PROPOSED SIGNAL POLE FOUNDATIONS AND EXISTING MODIFIED SIGNAL POLE FOUNDATIONS SHALL INCLUDE A CONCRETE PAD AROUND THE FOUNDATION. PROPOSED OR EXISTING SIDEWALK SHALL BE CONSIDERED PART OF THE FOUNDATION PAD. FOUNDATION PAD SHALL BE AT LEAST 2 FEET OFFSET FROM THE SIGNAL POLE FOUNDATION, AS SPACE ALLOWS OR UNLESS OTHERWISE APPROVED. 9. WHEN THE TRAFFIC SIGNAL IS OPERATIONAL, ALL DETECTION SHALL BE MAINTAINED AND REMAIN FUNCTIONAL FOR ALL SIGNAL PHASES. NEW PERMANENT/TEMPORARY VIDEO DETECTION SHALL BE INSTALLED AND OPERATIONAL PRIOR TO DESTROYING ANY EXISTING DETECTION. 10. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION SYSTEMS ARE SUBJECT TO INSPECTION BY CITY OF RENTON PUBLIC WORKS/TRANSPORTATION MAINTENANCE PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION MAINTENANCE MANAGER OR OTHER TRANSPORTATION REPRESENTATIVE. 11. NEW PTZ CAMERA SHALL BE REQUIRED WHEN A NEW TRAFFIC SIGNAL SYSTEM IS INSTALLED, WHEN LANE CONFIGURATION IS MODIFIED WITH NEW SIGNAL PHASING, AND/OR WHEN EXISTING PTZ CAMERA(S) REQUIRE RELOCATION. 12. ARROW BOARDS SHALL BE REQUIRED TEMPORARY TRAFFIC CONTROL WHEN CLOSING A TRAVEL LANE AND SHALL BE MUTCD COMPLIANT. G\ DEPARTMENT Y O TRANSPORTATION NOTES PUBLIC WORKS U �F N '� O� STD. PLAN - 135 ,PEBOV ED: 5/2/2024 1 4 Martin Pastucha T - DATE Docusign Envelope ID CAEEA226-F133431A-9622-23AB6EE84358 0 TRAFFIC SIGNAL CONTROLLER CABINET �0 1'(TYP.) (TYP.) 2(a \ o00 0 0 0 0 0 (TYP.)0 000 3 '- J U �2 \`&TYP. ) FRONT ELEVATION VEW - Vc" CHAMFERS NOT SHOWN KEY NOTES Oi GRID OF #3 REBAR SPACED AT 1'-0- CENTERS LATERALLY AND LONGITUDINALLY. O 4" DIAMETER X 112" DEEP SUMP SLOPE FOUNDATION WITHIN CABINET FOOTPRINT TOWARD SUMP. 0 3/8- DIAMETER POLYETHYLENE TUBING FOR DRAIN TUBING SHALL BE STRAIGHT BUT SLOPE DOWNWARD A MINIMUM OF 1" Q CONDUITS TO FIELD EQUIPMENT PER CONTRACT GENERAL NOTES. 1. FOUNDATION PADS AND RISERS SHALL BE CHAMFERED ON ALL EDGES TOP OF FOUNDATION PADS CONSTRUCTED WITHIN SIDEWALK SHALL BE FLUSH WITH TOP OF SIDEWALK AND NO CHAMFER ON PAD EDGES. TOP OF PAD SHALL BE FINISHED BY A CONCRETE CONTRACTOR. 2. CONCRETE SHALL BE CLASS 4000P. 3 PLACE A SILICONE SEAL BETWEEN THE FOUNDATION AND CABINET WOODEN SHIMS SHALL NOT BE USED 4. ANCHOR BOLTS AND THEIR SPACING TO BE SUPPLIED BY CABINET MANUFACTURER AND SUBMITTED TO THE CITY FOR APPROVAL. 5. CONDUIT SIZES/QUANTITIES SHALL BE INSTALLED PER THE CONTRACT PLANS, EXCEPT EACH CABINET SHALL HAVE ONE 2" SPARE INSTALLED BETWEEN CABINET AND CORRESPONDING JUNCTION BOX. 6. 2" CONDUIT SHALL BE PLACED FROM THE ELECTRICAL SERVICE TO THE CONTROLLER CABINET 7, REBAR SHALL MEET ASTM A706 GRADE 60 8. ALL REBAR DIMENSIONS ARE OUT TO OUT. 9. #3 BAR BENDS SHALL HAVE 1.5 INCH INSIDE DIAMETER FOR STIRRUPS AND TIES. ALL OTHER BARS SHALL BE 2.25 INCH INSIDE DIAMETER 10.#4 BAR BENDS SHALL HAVE 2 INCH INSIDE DIAMETER FOR STIRRUPS AND TIES, ALL OTHER BARS SHALL BE 3 INCH INSIDE DIAMETER. co O #4 s N O O #4 2'-6• 2'-0" 3'-6• REINFORCNO STEEL BENDI IO DIAGRAM Y O� PUBLIC WORKS N� DEPARTMENT 1 /8'. CABINET FOUNDATION DETAILS DIAMETER = 7/8" '..,� :. -1. y 4-7/8" 1/4 1. LOAD ri irr CUTTING P .. , FUSE KIT EOXY FILL INLINE SPLICE rflllVV rrr I W T z_ JI Ll I t LINE , id" SPICE KIT STD. PLAN - 126.2 k4aP440VE D : Martin Pastucha 4/14/2025 DATE 1/81, FUSE KIT & SPLICE KIT DETAILS ADOPTED CITY OF RENTON ♦I "'''""```��■��■������ �/ STANDARD PLANS ti,ry•O� LET DATE:04/04 nwr_ NAAAF• .Il71 i CP PCr.1 • .IC11 T ARCHITECTURE + PLANNING + DISIC 6211 ROOSEVELT WAY NORTHEAST SEATTLE, WA 98115 tel: (206) 522-3830 fax: (206) 522-2456 F TWB ENGINEERS= Travis Fitzmaurice Wartelle Balangue Engineers Inc. 1200 Westlake Ave. N., #509 Seattle, WA 98109 p:206-285-7228 1 info@tf-wb.conl PERMIT RESUBMI TTAL No. I Description Date: 6 City Comments 8/21/25 Project Title: Q 0ry O LU Z v Q Q w L `L Q z O � z O � z w LLI LGE y w z W _ o Qw ftft Uft TRANSPORTATION OPERATION CAP%) cbarnes 09/23/2025 Sheet Title: DETAILS - ELECTRICAL Scale: As indicated Project No.: 21-12 Date : 8/21/25 Sheet Number: E1z5 W NM W T O 'O L J N U �o O O O O I N rr n �M t' J O O O I N Z) R-435492