V-11 •
2'-6' 1'-11• 2'-6"
(TYP.) o
(TYP.) Q
(TYP.)
(TYP.) 7
PLAN VEW
CHAMFERS NOT SHOWN
(��
PUBLIC WORKS
�� � DEPARTMENT
�FNTO?
KEY NOTES
O GRID OF #3 REBAR SPACED AT V-0" CENTERS LATERALLY AND
LONGITUDINALLY.
0 4" DIAMETER X 1/2- DEEP SUMP SLOPE FOUNDATION WITHIN CABINET
FOOTPRINT TOWARD SUMP.
O 3/8" DIAMETER POLYETHYLENE TUBING FOR DRAIN. TUBING SHALL BE
STRAIGHT BUT SLOPE DOWNWARD A MINIMUM OF 1".
0 CONDUITS TO FIELD EQUIPMENT PER CONTRACT
O SERVICE ENTRANCE CONDUIT. ALIGN WITH SERVICE WIRE -WAY IN THE
CABINET.
Q SERVICE GROUND ELECTRODE CONDUITS.
Oi GROUND ROD GROUND RODS SHALL BE A MINIMUM OF 6 FEET APART,
GROUNDING SHALL BE PER WSDOT STANDARD PLAN J-60.05.
Qe GROUND ROD WELL (GROUND TILE) - 12" DIAMETER CONCRETE.
GENERAL NOTES
1. FOUNDATION PADS AND RISERS SHALL BE CHAMFERED ON ALL EDGES.
TOP OF FOUNDATION PADS CONSTRUCTED WITHIN SIDEWALK SHALL BE
FLUSH WITH TOP OF SIDEWALK AND NO CHAMFER ON PAD EDGES. TOP OF
PAD SHALL BE FINISHED BY A CONCRETE CONTRACTOR.
2. CONCRETE SHALL BE CLASS 4000P.
3. PLACE A SILICONE SEAL BETWEEN THE FOUNDATION AND CABINET,
WOODEN SHIMS SHALL NOT BE USED.
4, ANCHOR BOLTS AND THEIR SPACING TO BE SUPPLIED BY CABINET
MANUFACTURER AND SUBMITTED TO THE CITY FOR APPROVAL.
5. CONDUIT SIZES/QUANTITIES SHALL BE INSTALLED PER THE CONTRACT
PLANS, EXCEPT EACH CABINET SHALL HAVE ONE 2" SPARE INSTALLED
BETWEEN CABINET AND CORRESPONDING JUNCTION BOX
6 2" CONDUIT SHALL BE PLACED FROM THE ELECTRICAL SERVICE TO THE
CONTROLLER CABINET
7. REBAR SHALL MEET ASTM A706 GRADE 60.
8. ALL REBAR DIMENSIONS ARE OUT TO OUT.
9. #3 BAR BENDS SHALL HAVE 1 5 INCH INSIDE DIAMETER FOR STIRRUPS AND
TIES, ALL OTHER BARS SHALL BE 2.25 INCH INSIDE DIAMETER
10 #4 BAR BENDS SHALL HAVE 2 INCH INSIDE DIAMETER FOR STIRRUPS AND
TIES. ALL OTHER BARS SHALL BE 3 INCH INSIDE DIAMETER.
Oi #4
N E04 iV
� #14
2'-0- �i 1'-1• 1'-r
REINFORCING STEEL BENDING DIAGRAM
CABINET FOUNDATION
DETAILS
DocuSign Envelope ID: 894DB72E-3255-4A63-AOF1-38A20AAF74CA
GENERAL NOTES:
STD. PLAN - 126.1
U ,J. QVED:
Martin Pastucha 4/14/2025
DATE
1. ALL EXISTING TRANSPORTATION INFRASTRUCTURE FEATURES SHALL BE MAINTAINED ON LEVEL
GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES,
LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS).
2. ALL TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED ON LEVEL GRADE ONCE
CONSTRUCTION IS COMPLETE.
3. ALL EXISTING OR PROPOSED TRANSPORTATION INFRASTRUCTURE FEATURES WITHIN THE PROJECT
CONSTRUCTION LIMITS SHALL MEET CURRENT PROWAG ADA STANDARDS (I.E. JUNCTION BOXES
SHALL HAVE NON-SKID LIDS).
4. ALL NEW TRAFFIC SIGNALS SHALL BE CONSTRUCTED WITH FIBER COMMUNICATION CONNECTION
TO CITY OF RENTON TRANSPORTATION FIBER OPTIC NETWORK.
5. ALL TRANSPORTATION INFRASTRUCTURE FEATURES THAT ARE TO BE REMOVED AND REINSTALLED
AT A LATER DATE SHALL BE RE -INSTALLED TO CURRENT STANDARDS.
6. ALL CONDUIT SHALL BE PVC SCHEDULE 80.
7. SIGNAL POLE, LUMINAIRE, AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE.
8. ALL PROPOSED SIGNAL POLE FOUNDATIONS AND EXISTING MODIFIED SIGNAL POLE FOUNDATIONS
SHALL INCLUDE A CONCRETE PAD AROUND THE FOUNDATION. PROPOSED OR EXISTING SIDEWALK
SHALL BE CONSIDERED PART OF THE FOUNDATION PAD. FOUNDATION PAD SHALL BE AT LEAST
2 FEET OFFSET FROM THE SIGNAL POLE FOUNDATION, AS SPACE ALLOWS OR UNLESS
OTHERWISE APPROVED.
9. WHEN THE TRAFFIC SIGNAL IS OPERATIONAL, ALL DETECTION SHALL BE MAINTAINED AND REMAIN
FUNCTIONAL FOR ALL SIGNAL PHASES. NEW PERMANENT/TEMPORARY VIDEO DETECTION SHALL
BE INSTALLED AND OPERATIONAL PRIOR TO DESTROYING ANY EXISTING DETECTION.
10. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION
SYSTEMS ARE SUBJECT TO INSPECTION BY CITY OF RENTON PUBLIC WORKS/TRANSPORTATION
MAINTENANCE PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH
THE TRANSPORTATION MAINTENANCE MANAGER OR OTHER TRANSPORTATION REPRESENTATIVE.
11. NEW PTZ CAMERA SHALL BE REQUIRED WHEN A NEW TRAFFIC SIGNAL SYSTEM IS INSTALLED,
WHEN LANE CONFIGURATION IS MODIFIED WITH NEW SIGNAL PHASING, AND/OR WHEN EXISTING
PTZ CAMERA(S) REQUIRE RELOCATION.
12. ARROW BOARDS SHALL BE REQUIRED TEMPORARY TRAFFIC CONTROL WHEN CLOSING A TRAVEL
LANE AND SHALL BE MUTCD COMPLIANT.
G\ DEPARTMENT Y O TRANSPORTATION NOTES
PUBLIC WORKS
U
�F N '� O�
STD. PLAN - 135
,PEBOV ED: 5/2/2024 1 4
Martin Pastucha
T - DATE
Docusign Envelope ID CAEEA226-F133431A-9622-23AB6EE84358
0
TRAFFIC SIGNAL
CONTROLLER
CABINET
�0
1'(TYP.)
(TYP.) 2(a \ o00
0 0
0 0 0
(TYP.)0 000
3 '-
J
U �2
\`&TYP. )
FRONT ELEVATION VEW
- Vc"
CHAMFERS NOT SHOWN
KEY NOTES
Oi GRID OF #3 REBAR SPACED AT 1'-0- CENTERS LATERALLY AND
LONGITUDINALLY.
O 4" DIAMETER X 112" DEEP SUMP SLOPE FOUNDATION WITHIN
CABINET FOOTPRINT TOWARD SUMP.
0 3/8- DIAMETER POLYETHYLENE TUBING FOR DRAIN TUBING SHALL
BE STRAIGHT BUT SLOPE DOWNWARD A MINIMUM OF 1"
Q CONDUITS TO FIELD EQUIPMENT PER CONTRACT
GENERAL NOTES.
1. FOUNDATION PADS AND RISERS SHALL BE CHAMFERED ON ALL
EDGES TOP OF FOUNDATION PADS CONSTRUCTED WITHIN
SIDEWALK SHALL BE FLUSH WITH TOP OF SIDEWALK AND NO
CHAMFER ON PAD EDGES. TOP OF PAD SHALL BE FINISHED BY A
CONCRETE CONTRACTOR.
2. CONCRETE SHALL BE CLASS 4000P.
3 PLACE A SILICONE SEAL BETWEEN THE FOUNDATION AND CABINET
WOODEN SHIMS SHALL NOT BE USED
4. ANCHOR BOLTS AND THEIR SPACING TO BE SUPPLIED BY CABINET
MANUFACTURER AND SUBMITTED TO THE CITY FOR APPROVAL.
5. CONDUIT SIZES/QUANTITIES SHALL BE INSTALLED PER THE
CONTRACT PLANS, EXCEPT EACH CABINET SHALL HAVE ONE 2"
SPARE INSTALLED BETWEEN CABINET AND CORRESPONDING
JUNCTION BOX.
6. 2" CONDUIT SHALL BE PLACED FROM THE ELECTRICAL SERVICE TO
THE CONTROLLER CABINET
7, REBAR SHALL MEET ASTM A706 GRADE 60
8. ALL REBAR DIMENSIONS ARE OUT TO OUT.
9. #3 BAR BENDS SHALL HAVE 1.5 INCH INSIDE DIAMETER FOR
STIRRUPS AND TIES. ALL OTHER BARS SHALL BE 2.25 INCH INSIDE
DIAMETER
10.#4 BAR BENDS SHALL HAVE 2 INCH INSIDE DIAMETER FOR STIRRUPS
AND TIES, ALL OTHER BARS SHALL BE 3 INCH INSIDE DIAMETER.
co O #4
s
N O
O #4
2'-6• 2'-0" 3'-6•
REINFORCNO STEEL BENDI IO DIAGRAM
Y O�
PUBLIC WORKS
N� DEPARTMENT
1 /8'.
CABINET FOUNDATION
DETAILS
DIAMETER = 7/8"
'..,� :.
-1. y
4-7/8"
1/4 1.
LOAD
ri irr
CUTTING P .. ,
FUSE KIT
EOXY FILL
INLINE SPLICE
rflllVV rrr I
W T z_ JI Ll I t
LINE , id"
SPICE KIT
STD. PLAN - 126.2
k4aP440VE D :
Martin Pastucha 4/14/2025
DATE
1/81,
FUSE
KIT & SPLICE KIT DETAILS
ADOPTED
CITY OF RENTON
♦I
"'''""```��■��■������
�/
STANDARD PLANS
ti,ry•O�
LET DATE:04/04
nwr_ NAAAF•
.Il71 i CP PCr.1 • .IC11
T
ARCHITECTURE + PLANNING + DISIC
6211 ROOSEVELT WAY
NORTHEAST
SEATTLE, WA 98115
tel: (206) 522-3830
fax: (206) 522-2456
F TWB
ENGINEERS=
Travis Fitzmaurice Wartelle
Balangue Engineers Inc.
1200 Westlake Ave. N., #509
Seattle, WA 98109
p:206-285-7228 1 info@tf-wb.conl
PERMIT
RESUBMI TTAL
No. I Description Date:
6 City Comments 8/21/25
Project Title:
Q
0ry
O
LU
Z
v
Q
Q
w
L
`L
Q
z
O
�
z
O
�
z
w
LLI
LGE
y
w
z
W
_
o
Qw
ftft
Uft
TRANSPORTATION OPERATION CAP%)
cbarnes 09/23/2025
Sheet Title:
DETAILS - ELECTRICAL
Scale: As indicated
Project No.: 21-12
Date : 8/21/25
Sheet Number:
E1z5